Loading...
Yelm Food Cogary gary 5 Normal Microsoft Office Word Yelm Food Co-op Gordon’s Garden Center Building PermitsProjects will be reviewed and permits issued concurrently. This requires application and plans submitted as a package. Plans shall be scalable and dimensioned.Co-op plan submittal Site plan of ADA parking (van accessible)stall Site plan showing location and pedestrian path to ent ryShow emergency lighting plan Show egress plan out of north door. Reverse swing on exit door . Feather or level land where elevation change is greater than ½ inch. Use ADA thresholdPanic hardware on all doors along exit path . All doors swing in the direction of travelIf shelving used to demark exit path thru storage show anchorage to floor Show display and check /service counter planParallel ADA approach for check out counters is 38 inches. Service counters are 36 inches for parallel approachRaised work area will require hand rails on both sides of the stairs Plumbing permit required for 3 compartment sink and grease interceptor. Submit grease interceptor plan for review If the wall furnace is to be used in the storage are maintain a minimum of 3 feet clearance around the unit Remove sign requiring door to be open during working hours on the mutual door and place it on the west entry door. Gordon plan SubmittalSite plan showing exiting plan, location and access to public restrooms and accessible path to ADA parking. Provide plan detail of accessible path improvements required to meet ADA specificationsBuilding and plumbing and mechanical plan for the public restrooms Number of required exits 2. Separation 159 feet. Both must be ADA accessible.