20080347 Sewer 1 021309Eagle Plaza
1st Review 2-13-09
By RH and JD
1. Sewer construction note # 11 denotes connecting to existing 4"
Sanitary Sewer Stub. This is a 2" sewer Stub.
2. There are no existing sewer stub-outs on Yelm Avenue to serve this
property, They were deleted. The idea to the best of our knowledge
was to extend the 2" sewer stub-out at sta 5+87.04 down the back
side of the property.
3. We do not want Tank lids or Carson boxes in sidewalks due to
tripping hazards.
4. Please show size and location of grease interceptors where needed.
5. Is irrigation going to be connected to R.W. Mainline? If so, please
show location and means of connection.
6. Please show size of service lines and side sewers.
7. Please show the locations of Carson boxes with shut-off valves.
8. We need submittals for tanks and Appurtenances.
9. Sewer Spec addendum: All `Air Release, Vacuum Release and Combination
Air Release/Vacuum Release valves shall be a model D-021 Combination Air
Valve "MINI SAAR" sized according to the mfg. recommendation per pipe size.