Loading...
2385 TT-90 ENERGY CODEF~rescriptive Energy Code Compliance for Slagle Family and Duplex Housing: Zone 1 Project Information Contact information Plan 2385 This set of forms has been developed to assist permit applicants documenting compliance with the Washington State Energy Code, (2009 edition). This set is for structures built under the IRC and located in Climate Zone 1. The following forms provide much of the required documentation for plan review. The details noted here must also be shown on the drawings (WSEC 104.2). This form is not a substitute for the energy code itself. To obtain a copy of the energy code, go to the following web address. http://www.energy.wsu.edu/code Glazing 10 Glazing U-Factor r e D Vaulted Wall12 Wall• into Wall• extd s Slabb Option : Area oo Ceilin 2 g Above Below Below Floor on of Floor Vertical Overhead" U-Factor Ceiling Grade Grade Grade Grade R-49 or R_21 R-21 R-10 ~ I 13% 0.34 0.50 0.20 R-38 R-38 ~ TB R-10 R-30 2, Adv. Int R-49 or R-21 R-21 R-10 01I 25% 0.32 0.50 0.20 R-38 R-38 , .I,B R-10 R-30 2, Adv. lnt R-49 or R_21 R-21 R-10 ~ III Unlimited 0.30 0.50 0.20 R-38 R-38 ~ TB R-10 R-30 2, Adv. Int See WSEC table 6-1 for footnotes uiatuiy ~uieuuie r+uauinu w vut.unicn~ ^ Does not apply. (SEE INSTRUCTIONS) Using Prescriptive Option III. All glazing and doors meet maximum U-factor. Alternate heating size method submitted. ~ Option I or II, Glazing to floor area limit (WSEC 602.7.2) ^ Area weighted window, skylight or door U-factor (WSEC 602.7.2) [] As part of the heating system sizing calculation (IRC M1401.3 &WSEC 503.2.2) Radiant slab: ^ R-10 foam insulation, continuous with thermal break (WSEC 502.1.4.9) Chapter 9 Options Total of 1 Credit Required Opt. Opt. Description 1a Hi h Efficienc HVAC E ui ment 1 1 b Hi h Efficienc HVAC E ui ment 2 1c Hi h Efficienc HVAC E ui ment 3 2 Hi h Efficienc HVAC Distribution S stem 3a Efficient Buildin Envelo e 1 3b Efficient Buildin Envelo e 2 3c Su er-Efficient Buildin Envelo e 3 4a Air Leaka a Control and Efficient Ventilation 4b Additional Air Leaka a Control and Efficient Ventilation 5a Efficient Water Heatin 5b Hi h Effiecienc Water Heatin 6 Small Dwellin Unit 7 Lar e Dwellin Unit 8 Renewable Electric Ener Total Credits *1200 kwh 1.0 ~ 1.00 WSEC Prescriptive Worksheet (2010 edition) Zone 1 WSUEEPIO-010 Copyright 2010 Glazing Schedule Project Information Contact Information Plan 2385 Conditioned Floor Area 2385 Sum of UA for Heating System Sizing 116.2 Sum of All Glazing Areas From Below 321 Glazing to Floor Area Ratio 13.45% 602.7.2 Exception Ratio (not to exceed 1 %)C~ Exterior Doors Plan Component Door Percent Width Height Glazing Door Door .~.___ :_.:..., osf I t_f~rtnr r;ia~prt nt FPet ~"on Feet ~"°h Area Area UA Ent Door 0.200 1 3 6 s 20.0 4 0 Fire Door exem t door 0.540 1 2 e 6 8 17.8 9 r; One Exempt Swinging Door < 24 Square Feet Sum of Glazing Area, Door Area, and UA (do not include exempt door) ~ ~ 37.8 13.6 Area Weighted U = UA/Area 0.36 Sum of Area and UA for Heating system size only (include exempt door) 37.8 13.6 Vertical Glazing (Windows, Glazed doors using Exception 602.6 #1) Plan Component Glazing ID Descri tion Ref. U-factor Powder Room 0.320 Great Room 0.320 Great Room 0.320 Dinin Room 0.320 Dinin Room 0.320 Dinin Room 0.320 Den 0.320 Pla room 0.320 Bedroom 4 0.320 U er Ent 0.320 U er Ent 0.320 Bedroom 3 0.320 Master Bedroom 0.320 Master Bath 0.320 Bedroom 2 0.320 Utili Room 0.320 Bath 0.320 WSEC Prescriptive Worksheet (2010 Edition) Width Height Qt. Feet ~"°h Feet ~"~h 1 2 5 2 2 s 6 1 5 6 1 5 g io 1 5 1 1 7 s 5 1 5 5 1 6 4 s 1 4 4 s 1 4 2 3 2 2 1 4 4 1 6 4 1 4 4 1 4 4 1 2 3 1 2 3 Glazing Area UA 10.0 3.20 30.0 9.60 30.0 9.60 34.2 10.93 5.0 1.60 37.5 12.00 25.0 8.00 27.0 8.64 18.0 5.76 8.0 2.56 12.0 3.84 16.0 5.12 24.0 7.68 16.0 5.12 16.0 5.12 6.0 1.92 6.0 1.92 Sum of Area and UA 320.7 102.61 Area Weighted U = UA/Area 0.32 WSUEEPIO-010 Copyright 2010 vvos~~iaau v~a~n~b Plan Component Glazing ID Descri lion Ref. U Width Height ,__,. Feet ~"~ Feet ~~~- Sum of Area and UA Area Weighted U = UA/Area Doube Glazed Garden Windows Section 602.7.2 Exception Plan Component Width Height ID Descri lion Qt. Feet ~"0h Feet ~"`h Sum of Area Sum of Area X 3 (This total is automatically included in the glazing area total.) Glazing UA for Heating System Size Only = Area X 0.83 WSEC Prescriptive Worksheet (2010 Edition) Area UA Area UA WSUEEPIO-010 Copyright 2010 Simple Heating System Size: Climate Zone 1 t In/ormation Plan 2385 Indoor Design Temperature 70 Outdoor Design Temperature 20 Design Temperature Difference (0T) DT =Indoor -Outdoor Design Temp 50 Conditioned Floor Area 2385 Conditioned Volume 20,747 Glazing Copy Sum of UA from Glazing Schedule 116 Attic U-Factor X Area R-4g 0.027 1465 R-38 Advanced 0.026 Single Rafter or Joist Vaulted Ceilings U-Factor X Area R-38 Vented 0.027 Above Grade Walls U-Factor X Area R-21 0.056 2386 Floors U-Factor X Area R-30 0.029 1394 Below Grade Walls U-Factor X Area 2' Depth Walls 0.042 3.5' Depth Walls 0.041 7' De th Walls 0.037 Slab Below Grade F-Factor X 2' Depth 0.59 3.5' Depth 0.64 7' De th 0.57 Slab on Grade F-Factor X R-10 2' perimeter 0.54 R-10 Full -Heated 0.55 Sum of UA Envelope Heat Load Sum of UA X AT Air Leakage Heat Load ((Volume X 0.6) X DT) X .018)) Building Design Heat Load Air Leakage + Envelope Heat Loss Contact Inionnation = UA 39.6 - UA = UA 133.6 = UA 40.4 = UA = UA = UA 330 16491 Btu /Hour 11203 Btu /Hour 27694 Btu /Hour Building and Duct Heat Load 1.15 31848 Btu /Hour If ducts are located in unconditioned space: Sum of Building Heat Loss X 1.15 tf ducts are located in conditioned space: Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 150% 47772 Btu /Hour Building and Duct Heat Loss X 1.50 WSEC Prescriptive Worksheet (2010 Edition) WSUEEP10-010 Copyright 2010