Loading...
20120258 Permit Pkg 08222012City of Yelm Community Development Department Building Division Phone: (360) 458-8407 Fax: (360) 458-3144 Applicant: Name: MOUNTAIN TERRACE BUILDERS Address: 14730 STATE RT 507 YELM WA 98597 Property Information: Site Address: 14974 101ST AVE SE 13 Assessor Parcel No.: 81780001300 Subdivision: Contractor Information: Name: MOUNTAIN TERRACE BUILDERS Address: 14730 STATE FIT 507 YELM WA 98597 Contractor License No.: Project Information: Project: NEW RESIDENTIAL BUILDING Description of Work: Sq. Ft. per floor: LOT 13, PLAN 2668 First Second Third Garage Basement Fees: Item NEW RESIDENTIAL BUILDING MECHANICAL PLUMBING Permit No.: 20120258 Issue Date: 8/22/2012 (Work must be completed within 180 days) Phone: 360 -458 -1502 Owner: MOUNTAIN TERRACE BUILDERS LLC VINTAGE GREES Phone: Expires: 0/00 /0000 1130 Heat Type (Electric, Gas, Other): GAS Contractor MOUNTAIN TERRACE BUILDERS BEST CHOICE HEATING JR'S PLUMBING TOTAL FEES: Applicant's Affidavit: I certify that I have read and examined the information contained within the application and know the same to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of Yelm regulations including those governing zoning and land subdivision, and in addition, all covenants, easements and restrictions of record. If applying as a contractor, I further certify that I am currently registered in the State of Washi9glart. —� i�L>IZZI ( z Firm Lot: 13 Fees $16,920.25 $ 91.25 $ 132.00 $ 17,143.50 OFFICIAL USE ONLY # Sets of Prints: Final Inspection: Date: By: City of Yelm (36 ) 458 -8402 REC #: 00103532 8/22/2012 10:21 AM OPER: CO TERM: 001 REF #: 2724 TRAN: 33.0000 BUILDING PERMITS 20120258 17,143,50CR MOUNTAIN TERRACE BUILDERS 14974 101ST AVE SE 13 BLD -RES1 16,920,25CR MECH 91.25CR PL 132.000R TENDERED: 17,143.50 CHECK APPLIED: 17,143,50- CHANGE: 0.00 YELM COMMUNITY SCHOOLS PO BOX 476 YELM WA 98597 Clerk: Croy Terminal: 1 Receipt: 185688 Manual Receipt: NMOUNTAIN TERRAC NMOUNTAIN TERRAC MOUNTAIN, TERRACE BUILDERS 14730 SR 507 SE YELM , WA 98597 812212012 10:08 AM - -Price 1 CPF MITIGATION 3015.00 05- 028 /TerraAValley /Lot 13 Subtotal: Tax: 3015.00 Total: 0.00 3015.00 Check 2722 3015.00 Change Due: 0.00 THANK YOU • • CITY OF YELM RESIDENTIAL BUILDING PERMIT APPLICATION FORM Project Address: V-193� l00 U2-S> Parcel Subdivision: Lot #: k2, Plan #: 26,&a-19 Zoning: New Construction rl Re -Model / Re -Roof I Addition C1 Home Occupation Sign tl Plumbing ❑ Mechanical ❑ Mobile / Manufactured Home Placement CI Other Project Description /Scope of Work: WA,, -3 Project Value: -)3[ \� 0ob.4O Building Area (sq. ft) 1" Floor (\30 2ntl Floor WC6 Garage ID Deck Basement Carport atio 5(-0 # Bedrooms # Bathrooms_Jila Heatin : AS/ THER or ELECTRIC (Circle One) Are there any environmentally sensitive areas located on the parcel? ff yes, a completed environmental checklist must accompany permit application. BUILDING OWNER NAME: �c n� es AC2 u,\ arS LLL ADDRESS LW1 130 V 2Z w t EMAIL T�PLNC MGZ cuw CITY Y kit2n—STATE WA ZIP—ftbT5 YJ TELEPHONE &C C> 415-6 Sn2 ARCHITECT /ENGINEER LICENSE# ADDRESS EMAIL CITYI^aliC, STATE » ZIP QbAf1`1 TELEPHONE 253- 5-$N -10301 GENERAL CONTRACTOR TELEPHONE ADDRESS EMAIL CITY STATE ZIP FAX CONTRACTOR'S LICENSE # Mo�TRTGfY-iATE 1 WITY LICENSE # PLUMBING CONTRACTOR J Pkc�r -)OL TELEPHONE I&O 14C S 29°11 ADDRESS EMAIL CITY STATE ZIP FAX CONTRACTOR'S LICENSE # EXP DATE CITY LICENSE # MECHANICAL CONTRACTOR -R-e-4 Cholc2 TELEPHONE,253 95�Z /7oG ADDRESS EMAIL CITY STATE ZIP FAX CONTRACTOR'S LICENSE # EXP DATE CITY LICENSE # Copy of mitigation agreement with Yelm Community Schools, if applicable. I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above described property will be in accordance with the laws, rules and regulations of the State of Washington and the City of Yelm. �1 . / V Z h Z. Applicant's Signature Date Owner / Contractor / Owner's Agent I Contractor's Agent (Please circle one.) _ on- transferable and will expire if work authorized by such permit is not begun �f issuance, or if work is suspended or abandoned for a period of 180 days (.ie0) (360) �LJ rlI I AUG 0 :, 2012 BY 1 -,�Puo_ `f 2`/ - S�5'33 995 111 l � � � A r. E a (ull y y 4 1 l � � � A r. E N 01D 2T 55' E 10500' F � Q � • - - • 'a W \'.' t- 1 CT► � , 1 i i z I I I uj I cn I I S 25' MIN. 6" 0 FILE u�,,, I =. ,i BY--- -- -- -- - --- --- - - -- i w - A NORTHWEST HOME DESIGNING, INC. ' @ 4924109TH STREET SW LAKEWOOD, WA 98499 (253) 5648309 FAX-(253)5884)607 s www.NHDHumPh ooan Prescriptive Energy Code Compliance for Single Family and Duplex Housing: Zone 1 Project Intannation Lot 13 Vintage greens Contact Information MTB Mike Kem inski 360 507 0868 This set of forms has been developed to assist permit applicants documenting compliance with the Washington State Energy Code, (2009 edition). This set is for structures built under the IRC and located in Climate Zone 1. The following forms provide much of the required documentation for plan review. The details noted here must also be shown on the drawings (WSEC 104.2). This form is not a substitute for the energy code itself. To obtain a copy of the energy code, go to the following web address. http: /Iwww.energy.wsu.edu /code See WSEC table 6-1 for footnotes ❑ Does not apply. (SEE INSTRUCTIONS) Using Prescriptive Option III. All glazing and doors meet maximum U- factor. Alternate heating size method submitted. 0 Option I or II, Glazing to floor area limit (WSEC 602.7.2) ❑ Area weighted window, skylight or door U- factor (WSEC 602.7.2) ❑ As part of the heating system sizing calculation (IRC M1401.3 & WSEC 503.22) Radiant slab: ❑ R -10 foam insulation, continuous with thermal break (WSEC 502.1.4.9) Chapter 9 Options Total of 1 Credit Required Opt. Opt. Description 1a Glazing U- Factor Door 1c Vaulted 112 Wall- in° Wall- ext° Efficient Building Envelope 1 Slab ' Option 0Glazin Area1: Super-Efficient Building Envelope 3 U- Factor z Ceiling Above Below Below Floor s on 6 Small Dwelling Unit 7 / of Floor Vertical Oerhead it Grade Grade Grade Grade R49 or R -21 R -21 R -10 I 13% 0.34 0.50 0.20 R -38 R -38 R -10 R -30 Int.' TB 2, Adv. Oil 25% 0.32 0.50 R-49 or R -21 R -21 R -10 0.20 R -38 R -38 R -10 R -30 Int.' TB 2, Adv. 0III R49 or R -21 R -21 R -10 Unlimited 0.30 0.50 0.20 R -38 R -38 R -10 R -30 Int.7 TB 2, Adv. See WSEC table 6-1 for footnotes ❑ Does not apply. (SEE INSTRUCTIONS) Using Prescriptive Option III. All glazing and doors meet maximum U- factor. Alternate heating size method submitted. 0 Option I or II, Glazing to floor area limit (WSEC 602.7.2) ❑ Area weighted window, skylight or door U- factor (WSEC 602.7.2) ❑ As part of the heating system sizing calculation (IRC M1401.3 & WSEC 503.22) Radiant slab: ❑ R -10 foam insulation, continuous with thermal break (WSEC 502.1.4.9) Chapter 9 Options Total of 1 Credit Required Opt. Opt. Description 1a High Efficiency HVAC Equipment 1 lb High Efficiency HVAC Equipment 2 1c High Efficiency HVAC Equipment 3 2 High Efficiency HVAC Distribution System 3a Efficient Building Envelope 1 3b Efficient Building Envelope 2 3c Super-Efficient Building Envelope 3 4a lAir Leakage Control and Efficient Ventilation 4b Additional Air Leakage Control and Efficient Ventilation 5a Efficient Water Heating 5b High Effieciency Water Heating 6 Small Dwelling Unit 7 Large Dwelling Unit 8 Renewable Electric Energy Total Credits TIt a.0 1.0 D El El El El El El El El El El 1.00 WSEC Prescriptive Worksheet (2010 edition) Zone 1 WSUEEP10 -010 Copyright 2010 Glazing Schedule Project Information Contact Information Vinta a greens lot 13 MTB 1360 507 0868 Conditioned Floor Area 2535 Sum of UA for Heating System Sizing 192.6 Sum of All Glazing Areas From Belowl 280 Glazing to Floor Area Ratio 11.03% 602.7.2 Exception Ratio (not to exceed 1 %)� Exterior Doors Plan Component Door Percent Width Height Glazing Door Door ID Description Ref_ 1-1- factor Glazed of Feet ' °C^ Feet "'h Area Area I 1 Vertical Glazing (Windows, Glazed doors using Exception 602.6 #1) Plan Component Glazing ID Description Ref. U- factor front door great room 2.00 0.32 1 3 1.92 6 4.00 hall entry master cl 18.0 36.0 3.84 back door ©ME©E 2.00 3.20 entry 6 0.32 6 a 40.0 40.0 80.0 lutilty 0.32 master 0.32 master MMEME 0.32 master bath 0.32 MMEME MMEME One Exempt Swinging Door < 24 Square Feet NEMEN� NEENEENO Sum of Glazing Area, Door Area, and UA (do not include exempt door) Area Weighted U = UA/Area Sum of Area and UA for Heating system size only (include exempt door) 1 40-01 58.0 116.0 2.00 1 40.01 58.01 116.0 Vertical Glazing (Windows, Glazed doors using Exception 602.6 #1) Plan Component Glazing ID Description Ref. U- factor 24.00 great room 6.40 0.32 ©©E©E dining 1.92 0.32 4.00 hall entry master cl 20.48 0.32 3.84 hall entry ©ME©E 0.32 3.20 entry 2.56 0.32 bedrooms 0.32 MMEME lutilty 0.32 master 0.32 master MMEME 0.32 master bath 0.32 MMEME MMEME NEMEN� NEENEENO MMEME MMEME MMEME MMEME WSEC Prescriptive Worksheet (2010 Edition) Width Height Qt. Feet inch Feet i °Ch ©©E©E 24.00 20.0 6.40 12.0 ©©E©E 6.0 1.92 12.5 4.00 ©©E©E 20.48 12.0 3.84 20.0 ©ME©E 10.0 3.20 8.0 2.56 M©O©E MMEME MMEME MMEME ©©E©E MMEME MMEME NEMEN� NEENEENO MMEME MMEME MMEME MMEME NEENEENO ININEENO =MEMO Sum of Area and UA Area Weighted U = UA/Area Glazing Area UA 75.0 24.00 20.0 6.40 12.0 3.84 6.0 1.92 12.5 4.00 64.0 20.48 12.0 3.84 20.0 6.40 10.0 3.20 8.0 2.56 239.5 76. 64 64 0.32 WSUEEP10 -010 Copyright2010 Overhead Glazing Plan Component Glazing Width Height Sum of Area and UA Area Weighted U = UA/Area Doube Glazed Garden Windows Section 602.7.2 Exception Plan Component Width Height ID Description Qt. Feet Inch Feet Inch Sum of Area Sum of Area X 3 (This total is automatically included in the glazing area total.) Glazing UA for Heating System Size Only = Area X 0.63 WSEC Prescriptive Worksheet (2010 Edition) WSUEEP10 -010 Copyright 2010 Simple Heating System Size: Climate Zone 1 Project Information Vinta a greens 13 Indoor Design Temperature 70 Outdoor Design Temperature 17 Design Temperature Difference (AT) AT = Indoor - Outdoor Design Temp 53 Conditioned Floor Area 2535 Conditioned Volume 22815 Glazing Copy Sum of UA from Glazing Schedule 193 Attic U- Factor X Area R -49 0.027 1405 R -38 Advanced 0.026 Single Rafter or Joist Vaulted Ceilings U- Factor X Area R -38 Vented 0.027 Above Grade Walls U- Factor X Area R -21 0.056 2346 Floors U- Factor X Area R -30 0.029 1130 Below Grade Walls U- Factor X Area 2' Depth Walls 0.042 3.5' Depth Walls 0.041 7' Depth Walls 0.037 Slab Below Grade F- Factor X Len th 2' Depth 0.59 3.5' Depth 0.64 7' Depth 0.57 Slab on Grade F Factor X Lel R -10 2' perimeter 0.54 R -10 Full - Heated 0.55 l Sum of UA Envelope Heat Load Sum of UA X AT Air Leakage Heat Load ((Volume X 0.6) X AT) X.018)) Contact Information MTB UA 37.9 UA = UA 131.4 UA 32.8 = UA = UA UA 395 20920 Btu / Hour 13059 Btu / Hour Building Design Heat Load 33980 Btu / Hour Air Leakage + Envelope Heat Loss Building and Duct Heat Load 1.15 39076 Btu / Hour If ducts are located in unconditioned space: Sum of Building Heat Loss X 1.15 If ducts are located in conditioned space: Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 150% 58615 Btu / Hour Building and Duct Heat Loss X 1.50 WSEC Prescriptive Worksheet (2010 Edition) WSUEEP10-010 Copyright2010 cv U o �N N � � , � � � � W � c N m � f� � Q � � � � � W V �'o � � � �•UN � � � � � � � � U O >+ � � V � � � � � � Z � � � > q � � � � � � � � � � � ti � � � � � � � � "�' cmU � � ° a� � � � p � � � � c� � •a L � � � � � � � = ti 0 � Q � w .� -� � � ° � � � J � '_ (6 �I rv -C � � � � � N � 'eJ �� � m � � � � w � �' p� � U ~o c � L � � � � � ~ � � 'Q-Q� � � � Q W � � � � -v � O � � � � a' � c°� � U � �j cn Z C� Q- o i � o QHQ °� w Z .c � �' � (� � N � O �n cu z 0o W � '� �, � � �M � N � � L (a � O � W o N O � � � � � � >- c� Z U Q � i J J U N � a Q C� cn ,� _ — M :� � F-- � r � cn Z � � � � �, O -D O . . N ;� (Q ����E u � � � � J � � U a � � Q O `� � �� Q (B "� � N � V � �. ; � Z a � �C = � W � u� a� � cu cn � c °�, � � c c � � �p '� � ����� m � � m � Q (n m