Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
20120251 Permit Pkg 08202012
City of Yelm Community Development Department Building Division Phone: (360) 458-8407 Fax: (360) 458 -3144 Applicant: Name: SOUNDBUILT NW LLC Address: PO BOX 73790 PUYALLUP WA 98373 Property Information: Site Address: 1AA91 I nCKWnnn 1 N SF 108 Assessor Parcel No.: 78640110800 Subdivision: Permit No.: 20120251 Issue Date: 8120/2012 (Work must be completed within 180 days) Phone: 253 - 848 -0820 Owner: SOUNDBUILT NW LLC TAHOMA TERRA Lot: 108 Contractor Information: Name: SOUNDBUILT NW LLC Phone: Address: PO BOX 73790 PUYALLUP WA 98373 Contractor License No : Expires: 0 /00 /0000 Project Information: Project. NEW RESIDENTIAL BUILDING Description of Work: LOT 108, PLAN 1361 Sq. Ft. per floor: Heat Type (Electric, Gas, Other): First 925 Second 436 Third Garage 331 Basement Fees: Item Contractor Fees NEW RESIDENTIAL BUILDING SOUNDBUILT NW LLC $12,558.91 MECHANICAL SOUND HEATING & AC $ 84.75 PLUMBING RAINIER VIEW ROOTER $ 111.00 TOTAL FEES: $ 12,754.66 Applicant's Affidavit: I certify that I have read and examined the information contained within the application and know the same to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of Yelm regulations including those governing zoning and land subdivision, and in addition, all covenants, easements and restrictions of record. If applying as a contractor, I further certify that I am currently registered in the St f Wa inggttonp n Sionature Z/e Cv 9, Date OFFICIAL USE ONLY # Sets of Prints: Final Inspection: Date. Firm / /- Un �P()iLf N.W. I By. TRAN: 33.0000 BUILDING PERMITS 20120247 12,754.66CR SOUNDBUILT NW LLC 14439 LOCKWOOD LN BE 105 BLD -RES1 12,558.91CR MECH 84.75CR PL 111.000R TRAN: 33.0000 BUILDING PERMITS 20120249 12,873.94CR SOUNDBUILT NW LLC 14433 LOCKWOOD LN BE 106 BLD -RES1 12,678.19CR MECH 84.75CR PL 111.000R TRAN: 33,0000 BUILDING PERMITS 20120250 12,418.48CR SOUNDBUILT NW LLC 14427 LOCKWOOD LN BE 107 BLD -RES1 12,256.73CR MECH 71.75CR PL 90.000R TRAN: 33.0000 BUILDING PERMITS 20120251 12,754.66CR SOUNDBUILT NW LLC 14421 LOCKWOOD LN BE 108 BLD -RES1 12,558.91CR MECH 84.75CR PL 111.000R TENDERED: 77,875.69 CHECK APPLIED: 77,875.69- CHANGE: 0.00 City of Yelo (36 ) 458 -8402 REC #: 00103431 8/20/2012 1:38 PM OPER: CO TERM: 001 REF #: 14197 TRAN: 33.0000 BUILDING PERMITS 20120208 153.25CR SOUND BUILT HOMES, INC, 9979 DOTSON ST BE 90 BLD -RES2 153.25CR TRAN: 33.0000 BUILDING PERMITS 20120209 153.25CR SOUNDBUILT NW LLC 9973 DOTSON ST BE 89 BLD -RES2 153.25CR TRAN: 33.0000 BUILDING PERMITS 20120223 153.25CR SOUNDBUILT NW LLC 10012 JENSEN DR BE 54 BLD -RES2 153.25CR TRAN: 33.0000 BUILDING PERMITS 20120245 13,740,26CR SOUNDBUILT NW LLC 9980 JENSEN DR BE 56 BLD -RES1 13,537.01CR MECH 78,25CR PL 125-OOCR TRAN: 33.0000 BUILDING PERMITS 20120246 12,873.94CR SOUNDBUILT NW LLC 14445 LOCKWOOD LN BE 104 BLD -RES1 12,678.19CR MECH 84.75CR PL 111.000R CITY OF YELM RESIDENTIAL BUILDING PERMIT APPLICATION FORM Project Address: kgl,a I d LA, SF Parcel #: r 6A o ko CJ oc Subdivisionla, hC)11L2 1t Vr/.1 Lot # J5� Plan #: I ',') G; I Zoning: New Construction n Re -Model / Re -Roof / Addition ! Home Occupation Sign Plumbing Mechanical Mobile / Manufactured Home Placement Other Project Description /Scope of Work: Mbl Id 1'I eW �l ✓1c11 tt t�^� cy�� Project Value: _1 5Y1i F Il ) . Building Area (sq. ft) 1" FloorC 2n4 Floor43L Garage t� Deck Basement Carport Patio - # Bedrooms # Bathroornii Heating( ''OTHER or ELECTRIC (Circle One) Are there any environmentally sensitive areas located on the parcel? AJ0 ff yes, a completed environmental checklist must accompany permit application. ADDRESS C• Y 7S7 v EMAIL IL4cky� >o.„r CcrH CITY f�wwtwJ STATE_( ZIP TELEPHONE 153 -b'98 0870 n ; t cc 5 LICENSE # ADDRESS EMAIL Se. enginecr'� ' 4wxasf •tic; CITY1314tk P A,t,v.9 STATE_j,;d,_ZI TELEPHONE - Mg - /o /7 AjVJ TELEPHONE 53- `f -C 8.'a c ADDRESS c x EMAIL lucLy SOt n c l hrvntS.(cwi CITY 1�. `au��I STATE \ ZIP 3 FAX -53S- 031 CONTRACTOR'S LICENSE # EXP DATE / CITY LICENSE # =n'cr Vic4J ✓ TELEPHONE - & ADDRESS t 73170 EMAIL CITY w L✓ STATELc� ZIP 373 FAX ,153 -935 -/ S CONTRACTOR'S LICENSE # n l v t D EXP DATE CITY LICENSE # V r v` tnc. TELEPHONE ADDRESS 5526 115 St t <,0' $$ EMAIL 353- 87S-OASS CITY wl STATE_ d ZIP FAX CONTRACTOR'S LICENSE # hci 046 EXP DATE CITY LICENSE # Copy of mitigation agreement with Yelm Community Schools, if applicable. I hereby carttty that the above Inforrnation Is correct and that the construction on, and the occupancy and the use of the above described property will be in accordance with the laws, rules and regulations of the State of Washington and the City of Yelm. 044? !�92- _7-31 -I�L Appll nt's Signature Date Owner/ Contractor wner's Agent I ontractor's Agent (Please circle one.) All permits are non - transferable and will expire if work authorized by such permit is not begun within 180 days of Issuance, or if work is suspended or abandoned for a period of 180 days 105 Yelm Avenue West Yelm, WA 98597 www.ci•yelm.wa.us B Ya (860) 4584835 (360) 458 -3144 FAX LOT 3105 SF IAwERVIOUS AREA ROOF AREA: 1347 SF DRIVEWAY, WALK & PA TIO AREA; 240 SF 1587 SF SOUNDBUILT HOMES OT 108 TOHOMA TERRA 14421 LOCKWOOD LN SE YELM WA. 98597 Parcel # 78640110800 111111111M m 00110111m PRIVATE ROAD 5 890 1 0'45" E LOCKWOOD LANE SE SILT FENCE (TYP.) Uuz < Ln w {I }- z. < AP Ft VED 0 o 12N - - -_ N 9 5' APPROX AREA TO BE m CLEARED.ALL EXPOSED SOILS WILL BE MULCHED WHEN NOT m BEING WORKED m SILT FENCE m (TYR ) R � 5'1 Qm 15 if 00 12' 8SBL PJAI-1 ,JEA1q _ SRI V -._ESE DRY WELL PER THURSTAN COUNTY STANDARD um r�AOr 9 -i9 -�Z 91v SCALE I"=20' 0 10 20 T��- LOT 3105 SF IMPERVIOUS AREA: ROOF AREA: 1347 SF DRIVEWAY, WALK & PATIO AREA; 240 SF 1587 SF Ply, Ij6/ SOUNDBUILT HOMES LOT 108 TOHOMA TERRA 14421 LOCKWOOD LN SE YELM WA. 98597 Parcel # 78640110800 PRIVATE ROAD 5 890 10'45" E LOCKWOOD LANE 5E zn I 5 A 9 2" CAL. SILT FENCE (TYP.) I L1 r�2' w•w r. N APPROX. AREA TO BE CLEARED.ALL EXPOSED �u SOILS WILL BE 5' MULCHED WHEN NOT 1 BEING WORKED w� '61,111— ®� ' 5' 1 S82 BL M N TULIPIFERA JENSEN DRIVE y N _ � SE o M n SILT FENCE (TYP. ) x-- x-- K-- -x--x DRY WELL PER THURSTAN COUNTY STANDARD ® AP nFILL Z SCALE 1 " =20' 0 10 20 40 Prescriptive Energy Code Compliance for Single Family and Duplex Housing: Zone 1 Project Information Contact Infonnation Soundbuilt 1361 This set of forms has been developed to assist permit applicants documenting compliance with the Washington State Energy Code, (2009 edition). This set is for structures built under the IRC and located in Climate Zone 1. The following forms provide much of the required documentation for plan review. The details noted here must also be shown on the drawings (WSEC 104.2). This form is not a substitute for the energy code itself. To obtain a copy of the energy code, go to the following web address. http: /Iwww.energy.wsu.edu /code See WSEC table 6 -1 for footnotes Glazing xneduie Attacneo to uocumern Does not apply. (SEE INSTRUCTIONS) Using Prescriptive Option III. All glazing and ❑ doors meet maximum U- factor. Alternate heating size method submitted. [�] Option I or II, Glazing to floor area limit (WSEC 602.7.2) ❑ Area weighted window, skylight or door U- factor (WSEC 602.7.2) ❑ As part of the heating system sizing calculation (IRC M1401.3 & WSEC 503.2.2) Radiant slab: ❑ R -10 foam insulation, continuous with thermal break (WSEC 502.1.4.9) Chapter 9 Options Total of 1 Credit Required not not r)ascrintion 1a Glazing 1 b High Efficiency HVAC Equipment 2 1c High Efficiency HVAC Equipment 3 Wall13 Wall, int° Wall ext" Efficient Building Envelope 1 Slab° Option �� Area"': Glazing U- Factor Door Ceiling Vaulted Above I Below Below Floor' on 6 %of Floor U- Factor Large Dwelling Unit Ceiling} Grade Grade Grade Grade Vertical Overhead R49 or R -21 R -21 R -10 I 13% 0.34 0.50 0,20 R -38 R -38 , TB R -10 R -30 2, Adv. Int R -49 or R -21 R -21 R -10 ❑ ti 25% 0.32 0.50 0.20 R -38 R -38 TB R -10 R -30 2, Adv. Int. R49 or R -21 R-21 R -10 0111 Unlimited 0.30 0.50 0.20 R -38 R -38 int." TB R -10 R -30 2, Adv. See WSEC table 6 -1 for footnotes Glazing xneduie Attacneo to uocumern Does not apply. (SEE INSTRUCTIONS) Using Prescriptive Option III. All glazing and ❑ doors meet maximum U- factor. Alternate heating size method submitted. [�] Option I or II, Glazing to floor area limit (WSEC 602.7.2) ❑ Area weighted window, skylight or door U- factor (WSEC 602.7.2) ❑ As part of the heating system sizing calculation (IRC M1401.3 & WSEC 503.2.2) Radiant slab: ❑ R -10 foam insulation, continuous with thermal break (WSEC 502.1.4.9) Chapter 9 Options Total of 1 Credit Required not not r)ascrintion 1a High Efficiency HVAC Equipment 1 1 b High Efficiency HVAC Equipment 2 1c High Efficiency HVAC Equipment 3 2 Hi h Efficiency HVAC Distribution System 3a Efficient Building Envelope 1 31b Efficient Building Envelope 2 3c Super-Efficient Building Envelope 3 4a Air Leakage Control and Efficient Ventilation 4b Additional Air Leakage Control and Efficient Ventilation 5a Efficient Water Heating 5b High Effieciency Water Heating 6 Small Dwelling Unit 7 Large Dwelling Unit 8 1 Renewable Electric Energy Total Credits `1200 kWh V:/ �t "0 Al 1.0 1.00 El El El El El El El El El El WSEC Prescriptive Worksheet (2010 edition) Zone 1 JUL 6 1 LU IL WSUEEPI0 -010 Copyright 2010 BY--------------------- Glazing Schedule Pm ect Inrormation Contact Inlormanon Soundbuilt 1361 Conditioned Floor Area I 1437 Sum of UA for Heating System Sizing 64.7 Sum of All Glazing Areas From Belowl 160 Glazing to Floor Area Ratio 11.11 % 602.7.2 Exception Ratio (not to exceed 1 %)� Exterior Doors Plan Component Door Percent Width Height Glazing Door Door ❑Pf I Lf.,tnr raa7Pr1 nt FPPt Inch Feet Inch Area Area UA v Vertical Glazing (Windows, Glazed doors using Exception 602.6 #1) Plan Component Glazing ID Description Ftet. u- factor Entry Door LIVING ROOM 0.200 0.320 1 3 10.320 1 61 8 MASTER BEDROOM 20.0 4.0 Fire Door (exempt door MMEME 0.540 1 2 e 61 a 17.8 9.6 MSTR BEDROOM 0.320 BEDROOM 2 0.320 BEDROOM 3 ENMEMO 0.320 STAIR 0.320 0MEMM ©©E©N MMEME One Exempt Swinging Door < 24 Square Feel MENEM =NM1� Sum of Glazing Area, Door Area, and UA (do not include exempt door) Area Weighted U = UA/Area Sum of Area and UA for Heatinq system size only (include exempt door) 37.8 13.6 0.36 37.8 13.6 Vertical Glazing (Windows, Glazed doors using Exception 602.6 #1) Plan Component Glazing ID Description Ftet. u- factor Nl M LIVING ROOM 0.320 MMEMN LIVING ROOM 10.320 0.320 MASTER BEDROOM DINING ROOM MMEME 0.320 KITCHEN 0.320 MSTR BATH 0.320 M©N©E MSTR BEDROOM 0.320 BEDROOM 2 0.320 BEDROOM 3 ENMEMO 0.320 STAIR 0.320 0MEMM ©©E©N MMEME MENEM =NM1� IMEME MENEME MMEMN' MEMEM WSEC Prescriptive Worksheet (2010 Edition) Width Height rtt FPPt Inch Feet "0 ©©MM� Nl M �MZ MMEMN MMEME MMEME M® MEW ©©O©M __ MINNE M©N©E __ MONIM EN©MMO __ INNIME ENMEMO MIMM __ Mme' 0MEMM ©©E©N MMEME MENEM =NM1� IMEME MENEME MMEMN' MEMEM �MENNE MMEMN IMEMEN MEMEM Sum of Area and UA Area Weighted U = UA/Area Glazing Area UA r r Nl M �MZ M® MEW MIME __ MINNE __ MONIM MINNE __ INNIME MIMM __ Mme' 159.61 51.07 032 WSUEEPIO -010 Copyright 2010 Simple Heating System Size: Climate Zone 1 Project Information Soundbuilt 1361 Indoor Design Temperature Outdoor Design Temperature Design Temperature Difference (AT) AT = Indoor - Outdoor Design Temp Conditioned Floor Area Conditioned Volume Glazing Copy Sum of UA from Glazing Schedule Attic U- Factor X R-49 0.027 R -38 Advanced 0.026 Single Rafter or Joist Vaulted Ceilings U- Factor R -38 Vented 0.027 Above Grade Walls U- Factor R -21 0.056 Floors U- Factor R -30 0.029 Below Grade Walls U- Factor 2' Depth Walls 0.042 35 Depth Walls 0.041 7' Depth Walls 0.037 Slab Below Grade F- Factor 2' Depth 0.59 3.5' Depth 0.64 7' Depth 0.57 Slab on Grade F- Factor R -10 2' perimeter 0.54 R -10 Full - Heated 0.55 Sum of UA Envelope Heat Load Sum of UA X AT Air Leakage Heat Load ((Volume X 0.6) X 4T) X .018)) 70 19 51 948 11,432 erJ Area 925 X Area X Area 1912 X Area 925 X t, 1: Contact Information = UA 25.0 = UA UA 107.1 UA 26.8 UA UA UA 224 11400 Btu / Hour 6297 Btu / Hour Building Design Heat Load 17697 Btu / Hour Air Leakage + Envelope Heat Loss Building and Duct Heat Load 1.15 20352 Btu /Hour If ducts are located in unconditioned space. Sum of Building Heat Loss X 1.15 If ducts are located in conditioned space. Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 150% 30528 Btu / Hour Building and Duct Heat Loss X 1.50 WSEC Prescriptive Worksheet (2010 Edition) WSUEEP10 -010 Copyright 2010 M Q O � N � d' � � � � � � } Ln �, c'7 � i C � Q � � '� � (6 ` �' � � w V �o �� � � �•VN � � � � � a`� � U Cj � � � � o � � � � � � � � �I � Z � V � � � � �`'' p a. °' •� � � � � � � � � om � �, a? � � � •� � f�6 N O � .� Lcn °' � � � � � o �1.1 p�j N � � ~ •N ^ � 1 � � �� V �~ v � »� � � � � � � � N ,� •� M �i � � � Z U � � J J �j U � tn J C � L � �� � Z Q � Q-� (6 > � O � Y J � > � U QU �i U � `� a � co ° � O OxJ N `_ � O .c� � cfl W cn N � m � N � � J � � � OO � O Z � � U � (� � � N V Q L g � U � � � a � .� � � � E o �-- � � � �, z i— � . . � N +, 0 � o N N � � t6 e � � � � J U � U �� � (B "a � � � � � Q Z Q � � V � � i � � (0 fn � � � � C C � � � � � � m � 0 m � Q � m s � ti . � . , lluct Leaisaes Affidavit . Pennit#: �� �Z G" `2,.�'( � . . • . � � ' . � � f � � �'- `� . Housa address orlo#-number.� ��_ ,�a��cY�a� . 5� .�[iV- �' �� City: _��� �� �� . • � � � w� P• _ . � . Cond.Ffoor Area(ft?):: �1 ���� Source(circie one): Plans�. Es�mated Measured � ❑Duct tightness testing is not r�quirec}for�tis.residence per exceptions�sted at the end af tivs dccument Air Nand{er ir�conditioned space7 Q.yes�na Air Handler present during test?�yes Q no. . Circle Test Mefhad: � l.eakage to dutside Tota1 Leakage ' . MaxJmum duc!l'sakage: _ . � : t . . Post Ccnstruction,#ota�duct leakage:(floac area x..08)=_�,__^C���25 Pa.�' � . Post Ccnstructlon,teakage to outdoors:{floar area x�.Q6)=�_C����pa • • . � � Rcpgh-tn,tota[duct lealcage wit�,air�hand[er inatalled:{floar area x,pfi}- ����CFM@25 Fa � ' Rough-In,tetal duct leakage with air haridl�r nct iastalted:(flodr area x.�4)=P�C�M��Pa �. ?est Ftesut� CFM@25Pa � : � Ring.(circle cne if appficabie): � Qpen ' � � 2 3 . � . Duct Tester Lacation: ?��' � �`. l� Pressure T�p Locatiort: �� 4 ',' � ` � 1 cas3,��t7�as th�s�d��ct l��+�ag�r���s�r�ac�s�r���and d�t�a�r�ia��s� usang�;,������ds�c3 i�sti��p�o#�,�r��. . Com�zny�lw�- ��,.L...��"� `' � .� �-�d � � �i��hnicia�: ��;:���;�--� '�.-�.:..r•s�:�J�� � � , . i ac;�nfcian SignG�ur���" " �-� Dais: -�. � '� r Phone�lumber. ����-^-� ;��� bVas�ingion S1at$�r�engy Cr�d�r�f�rsrocE: - �U3.1a,3 Ss�Iing.A!f ducis,afrhandier,fifter box�s,and bul)ding cz��iiies usa�:s ducts shail�b�,�ale�,�r,in�s a �n!ifT1 SeCilor,TA'1EQ1.3 of?�;P h7t�mafion�,r,=:�,���ntral C�:da er EOv.?ei!i�fn,l_fi�ri ; !: �� , f1d 5�97178 3h�11 c�n�iy cor,n«ct�d tc v2rinj ih2t�'�e ducis=_r:�s:;1��'..A sigr�a�fida��ii Jccu�ei�tirg�hQ fos�zsu(ts;h211 he p�.IdE+o he jurt c�iC or hanr�q�� �c:thotity b;;!h�r=sine_cent.?n/1-e^;reLir�d L��L'�e b�,�iidi�;g e�;icial,!ne tesi snai!�E ccr;du�ed ir!he nr�senc�of deoartmeht:t�r. E:c��iicr�: i. G�1r„'tfghi„e�s't�si�noi r�r���ir:;�f G'�e�ir hordl2r ard all dur.is 3ry locai��raiihin cor:ditiorv=d so?r,�. .!. U4G:(2s�li�^y;S i:G?i 3l"{Ulfyt]I!(fl�fU1T12w!S 3�Qf:�if';-;;yg�t im0 GCl71��i5i1CP'��C{IcP,C'::1f15�21I�S�!ilil Ul1Cr'f70PJG71E�3G3C2. :=.in�;;imu��ei;ix t.:�i or cor,rec'te�duct,vc,'<in th�;ur,c.:rdincr2d spe�is�1io�r,ad.Al!additionel suppfy and ratum du�s a�1al{42'Dsithir?t�;v ri+ndriiCl?Gj=c.�r.s.L1�c� C ^r� �� .. .J L'�:.��4°�i�-L:.i;4ii;' � ;ii3ulat:C�7i7 il i ,.�, � 'iy t • " vl�m.r j4:2�$37!Zi����8�i i � �.,. i .a . . . _ ._ ?fT':. r 1.;.� :fi��i!�2�ii':fi iCi 3f'O'i �i''C:;�l.r a _ 3`�'�:'P,' 3 TG:;��.'.JYB, 14� ;:c�-al"!3^C a?r�,. " .� rd'-;,'rr_;�:i ai5i2r`,t insuiaticn�hzn�Tilthlil 3 5120 cr F � . . . .� D�rz� testing Cal�uJato�(11��e� Ca�s�rurti�n) _ House address or tot#: S. � � � 4 Conditioned Floor Area:-� � � �� ._ 3 . Duct tester location: - � _ Pressure tap focation: "�,�— ov� Ring{if app(icable}: open 1 2 3 � ���" �^ At Raugh-tn {Totaf Leakage) Test Method & Test� � Cakutated 5tand"a�d? C�M�• 'Target Air Handler Present � : 5 6 CFM��er 10Q sf of CFA A6 X�CFA< CFM� . Air Handler�at,Preserrt � • . S 4 CFM�per 100 sf of CFA . •�X CFA�s CFM� � Post Cons�tart�vn � Test Met�od & •TestZ Calcu(ated . � Standardl . C�MZS Target , Air Handler Pcesern(TotaF Leakage) . 5 8 CFM�per 100 sF af CFA • .0$X CFA s_��pR�. : •Air Handler Present(Leaka�e to Fxter�4r) S 6 CFM�per 1Q0 sf of CFA .Q6 X—�,CFA 5��CFM� -- - 3: Test results rrzwt compty with ane of the Standards options, ` 2. Test CFM�mus#be equa!to oF less�an the calcuiated targAt. • � ' A��L�a�c��� t�s�i�g Calct���►#�v�(������fl�a� Tes�) Standard � � Tested . � � . � � CFMSo Cakulated Test Res�ht ' ' , � �{f�CFMSQ X 0.055}� 1 1 CFA X 144))=SLA aaao�� st� gC� � . � � � , . ��_ ddvicied by l�S`l� = S�A i S�=c�.C1oU�7 j -------�. Glossa�i � • �tough-ln: After installation of the com plete air dis�ribution systan btirt before instaliation of ins�latia�and sheet roc�. A)►o�r�s for access to atl duct searr�s and connections far r�-evafuativr�o�sea!int.g�ifi���,,zndard is not mQt in intitial t�si Pfls=�or�s"�ru�-tio�: ,�t or ne�r f nal inspection. 7"ne horna mu��e complFte�nou;;�ta;�ressuriz�t:��h�me to 25 pa. �0�3��.=a��:�A�ore�aiion ofthe entirz sys-tems duct lea,'cage in a duct tast. • �.28:Ca59�0 �X:°PIOT; .46a�oc�fOT G�aII+�liCi�"�JS�Biil I2cY5�0'�}1Q 2:CL�C1C�OT tZ'IE��Si lil�diJ�t25i. LF�1: Conditionec!floor ar�a , '��3�;: Cuoic f�e�p°,-min�i=oi ai;iea4ao�at S pasc�ls o"�r=�;ur� ' _ �r?`��:o; Cubic fe,t per�ninut�of air lea4age at 50�asca(s o�przssure ' �as�a!{�a}: Unit af��assure — �W: Specific ieakage arza - � i I