Loading...
20120249 Permit Pkg 08202012City of Yelm Community Development Department Building Division Phone: (360) 458-8407 Fax: (360) 458-3144 Applicant: Name: SOUNDBUILT NW LLC Address: PO BOX 73790 PUYALLUP WA 98373 Permit No.: 20120249 Issue Date: 8120/2012 (Work must be completed within 180 days) Phone: 253 - 848 -0820 Property Information: Site Address: 14433 LOCKWOOD LN SE 106 Owner: SOUNDBUILT NW LLC Assessor Parcel No.: 78640110600 Subdivision: TAHOMA TERRA Lot: 106 Contractor Information Name: SOUNDBUILT NW LLC Phone: Address: PO BOX 73790 PUYALLUP WA 98373 Contractor License No.: Expires: 0 /00 /0000 Project Information: Project: NEW RESIDENTIAL BUILDING Description of Work: Sq. Ft. per floor: LOT 106, PLAN 1437 First 714 Second 723 Third Garage 504 Basement Fees: Item NEW RESIDENTIAL BUILDING MECHANICAL PLUMBING Heat Type (Electric, Gas, Other): Contractor Fees SOUNDBUILT NW LLC $12,678.19 SOUND HEATING 8 AC $ 84.75 RAINIER VIEW ROOTER $ 111.00 TOTAL FEES: $ 12,873.94 Applicant's Affidavit: I certify that I have read and examined the information contained within the application and know the same to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of Yelm regulations including those governing zoning and land subdivision, and in addition, all covenants, easements and restrictions of record. If applying as a contractor, I further certify that I am currently registered in the Sta%te�of Wa /shington. '4P ® Signature l_.ry�(. 4i 4 y, Date Finn A �VA d bal} A4 W . OFFICIAL USE ONLY # Sets of Prints: Final Inspection: Date: By: TRAN: 33.0000 BUILDING PERMITS 20120247 12,754,66CR SOUNDBUILT NW LLC 14439 LOCKWOOD LN SE 105 BLD -REST 12,558.91CR MECH City of YeIN 84.75CR (36 ) 458 -8402 PL 111.000R TRAN: 33.0000 BUILDING PERMITS 20120249 12,873.94CR SOUNDBUILT NW LLC 14433 LOCKWOOD LN SE 106 BLD -REST 12,678,19CR MECH 84,75CR PL 111.000R TRAN: 33.0000 BUILDING PERMITS 20120250 12,418,48CR SOUNDBUILT NW LLC 14427 LOCKWOOD LN SE 107 BLD -RES1 12,256.73CR MECH 71.75CR PL 90.000R TRAN: 33.0000 BUILDING PERMITS 20120251 12,754.66CR SOUNDBUILT NW LLC 14421 LOCKWOOD LN SE 108 BLD -RES1 12,558.91CR MECH 84,75CR PL 111.000R TENDERED: 77,875.69 CHECK APPLIED: 77,875.69- CHANGE: - O REC #: 00103431 812012012 1:38 PM OPER: CO TERM: 001 REF #; 14197 TRAN: 33.0000 BUILDING PERMITS 20120208 153.25CR SOUND BUILT HOMES, INC. 9979 DOTSON ST SE 90 BLD -RES2 153.25CR TRAN: 33,0000 BUILDING PERMITS 20120209 153.25CR SOUNDBUILT NW LLC 9973 DOTSON ST SE 89 BLD -RES2 153.25CR TRAN: 33.0000 BUILDING PERMITS 20120223 153.25CR SOUNDBUILT NW LLC 10012 JENSEN OR SE 54 BLD -RES2 153-25CR TRAN: 33.0000 BUILDING PERMITS 20120245 13,740.26CR SOUNDBUILT NW LLC 9980 JENSEN DR SE 56 BLD -RES1 13,537.01CR MECH 78.25CR PL 125.000R TRAN: 33.0000 BUILDING PERMITS 20120246 12,873.94CR SOUNDBUILT NW LLC 14445 LOCKWOOD LN SE 104 BLD -RES1 12,678.19CR MECH 84.75CR PL 111.000R CITY OF YELM Z ' `" — zq n i RESIDENTIAL B11 UILDING PERMIT APPLICATION FORM Project Address: 149 �� 1 OC t&4 S 6 Parcel #: Subdivision I O ^ 0 J2rfeA_ Lot #: 1 Plan*: I 7J1 Zoning: New Construction : Re -Model / Re -Roof / Addition _. Home Occupation Sign Plumbing )(Mechanical E Mobile / Manufactured Home Placement :] Other Project Description /Scope of Work: I-)Ui 10 / IGW I Y IUI r io mt t + t r I U rr I C-, Project Value: 2� 1 Building Area (sq. ft) 1 n Floor J 2ntl Floor Garage Deck Basement Carport Patio # Bedrooms, # Bathrooms-4,L,J Heatin : GAS /f THER or ELECTRIC (Circle One) Are there any environmentally sensitive areas located on the parcel? 4� Lo— H yes, a completed environmental checklist must accompany permit application. i N ,V.,, ADDR SS C• 7'-S790 EMAIL IkcLy CITY �a}W_STATE ' " ZIP ]J? TELEPHONE �Xhck nc c LICENSE # ADDRESS EMAIL . a ev,)A 7 cct- f •ucJ CITYi3CactDrAr .J STATE yA ZI qC lr TELEPH E 3c0 33v /oil AJVJ TELEPHONE 53- 9 c8ao ADDRESS c o EMAIL Lie Sovh be l eS.COwt CITY STATE 1 ZIP Y lr37 3 FAX - 5 3 S- G :3l _ CONTRACTOR'S LICENSE #<4a d NL9ll e.L EXP DATES CITY LICENSE # 02-'hie;7 iCIJ ac / TELEPHONE 2,53- - 9(0 ADDRESS ✓ 737170 EMAIL CITY w t_� STATE lug ZIP 9937 3 FAX ,.953- 935- / S CONTRACTOR'S LICENSE # ^ 7 n I v tOF EXP DATE CITY LICENSE # Anu�YJ AW w „ InC TELEPHONE .� ADDRES �_St t EMAIL 53-875--0:299_ CITY STATE W ZIP fr37 FAX CONTRACTOR'S LICENSE # EXP DATE CITY LICENSE # Copy of mitigation agreement with Yelm Community Schools, if applicable. I hereby certify that the above Information is correct and that the construction on, and the occupancy and the use of the above described property will be In accordance with the laws, miss and regulations of the State of Washington and the City of Yelm. 1:6 *2 !�X/- App�nt's Signature/' -—, Date Owner / Contractor wner's Agent /Contractor's Agent (Please circle one.) All permits are non - transferable and will expire if work authorized by such permit is not begun within 180 days of issuance, or if work is suspended or abandoned for a period of 180 days 105 Yelm Avenue West Yelm, WA 98597 WWW.ci.yelm.Wa.us All " 20 W FAX m, r X012 o LOT 3105 SF IMPERVIOUS AREA: ROOF AREA: 1385 SF DRIVEWAY, WALK & PATIO AREA; 360 SF 1745 SF se 0" 1q3 SOUNDBUILT HOMES LOT 106 TOHOMA TERRA 14433 LOCKWOOD LN SE YELM WA. 98597 Parcel # 78640110600 PRIVATE ROAD 5 89010'45" E LOCKWOOD LANE SE `e ( - b'g ZN W Uo O w K - n LI 1 g'--..-. m N d� 1'� J m L 1437 5, 5' R.� 12' BSBL j 3 JENSEN DRIVE 5E o LINOOENDRON \ 2" CAL. MIN. N SILT FENCE ( TYP. ) APPROX. AREA TO BE CLEARED.ALL EXPOSED SOILS WILL BE MULCHED WHEN NOT BEING WORKED SILT FENCE ( TYP. ) DRY WELL PER THURSTAN COUNTY STANDARD r C' SCALE 1' =20' 0 10 20 40 I- OPEN SPACE 0.42 AC ' ---TRACT B AP R VED OPEN FN SA N �SE 0 F I L SP A AE Rl VE 0.4 2 C L�NOO�uuF�-L-�, I r 2" CAL MIN. _ TRACT B f-) /10-1 l /C/3`7 LOT SOUNDBL!IL F HOMES 3105 SF IMPERVIOUS AREA: ROOF AREA: 1385 SF LOT 106 T u O V A TERRA DRIVEWAY. WALK 14433 LOCK WOOD LN SE & PAPA 0IO AREA; 360 SF 1745 SF YELM WA. 98597 Parcel # 78640110600 PRIVATE ROAD 5 890 1 045" e LOCKWOOD LANE SE ow _ - r7 _ � O U N 7 LI 18 APPROX. AREA TO BE CLEARED.ALL EXPOSED S 5' SOILS WILL BE MULCHED WHEN NOT BEING WORKED SILT FENCE N m (iYP ) n m U DRY WELL PER THURSTAN COUNTY 1437 STANDARD 5' P! AN 5 m� L6 °� o SCALE I"=20' 12' 8SBL r ® w rn 0 70 20 40 i ; AP R VED OPEN FN SA N �SE 0 F I L SP A AE Rl VE 0.4 2 C L�NOO�uuF�-L-�, I r 2" CAL MIN. _ TRACT B R;escriptive Energy Code Compliance for Single Family and Duplex Housing: Zone 1 Protect Information Contact Information Soundbuift 1437 This set of forms has been developed to assist permit applicants documenting compliance with the Washington State Energy Code, (2009 edition). This set is for structures built under the IRC and located in Climate Zone 1. The following forms provide much of the required documentation for plan review. The details noted here must also be shown on the drawings (WSEC 104.2). This form is not a substitute for the energy code itself. To obtain a copy of the energy code, go to the followinq web address httpJlwww.energy.wsu.edu /code See WSEC table 61 for footnotes Glazing Schedule Attached to Document - -- -- Does not apply. (SEE INSTRUCTIONS) Using Prescriptive Option 111. All glazing and ❑ doors meet maximum U- factor. Alternate heating size method submitted. E] Option I or II, Glazing to floor area limit (WSEC 602.7.2) ❑ Area weighted window, skylight or door U- factor (WSEC 602.7,2) ❑ As part of the heating system sizing calculation (IRC M1401.3 & WSEC 503.2.2) Radiant slab: ❑ R -10 foam insulation, continuous with thermal break (WSEC 502.1.4.9) Chapter 9 Options Total of 1 Credit Reguired Glazing ient HVAC E ui ment 2 ient HVAC E ui ment 3 Wall' Wall int' Wall ext" uildin Envelo e 1 Slab° Building En elope 2 3c Glazing U- Factor v Door Veiling' Vaulted Above Below Below Floor on Option Area %of Floor U- Factor Lar a Dwelling Unit Ceiling' Grade Grade Grade Grade Vertical Overhead�� R-49 or R -21 R -2i R -10 C�� 1 13% 0.34 0.50 0.20 R -38 R -38 Int.' TB R -10 R -30 2, Adv. R-49 or R -21 R -21 R -10 Q It 25% 0.32 0.50 0.20 R -38 R -38 Int.' TB R -10 R -30 2, Adv. R-49 R -21 R -21 R -10 DIII Unlimited 0.30 0.50 0.20 R -38 R -38 Int.' TB R -10 R -30 2, Adv. See WSEC table 61 for footnotes Glazing Schedule Attached to Document - -- -- Does not apply. (SEE INSTRUCTIONS) Using Prescriptive Option 111. All glazing and ❑ doors meet maximum U- factor. Alternate heating size method submitted. E] Option I or II, Glazing to floor area limit (WSEC 602.7.2) ❑ Area weighted window, skylight or door U- factor (WSEC 602.7,2) ❑ As part of the heating system sizing calculation (IRC M1401.3 & WSEC 503.2.2) Radiant slab: ❑ R -10 foam insulation, continuous with thermal break (WSEC 502.1.4.9) Chapter 9 Options Total of 1 Credit Reguired Total Credits WSEC Prescriptive Worksheet (2010 edition) Zone 1 `1200 kwh LL:3d-6 \!y JUL U 1 2012 BY- -------------- - - - - -- 1.0 El 1.00 WSUEEP10-010 Copyright2010 ent HVAC E ui ment 1 ient HVAC E ui ment 2 ient HVAC E ui ment 3 p3a ient HVAC Distrbution Sstem MicientBuildving uildin Envelo e 1 Building En elope 2 3c icient Buildin Envelo 3 4a Air Leakage Control and Efficient Ventilation 4b Addi tional Air Leakage Control and Efficient Ventilation 5a Efficient Water Heating 5b Hi h 'Effieciency Water Heating 6 Small Dwelling Unit 7 Lar a Dwelling Unit 6 Renewable Electric Ener Total Credits WSEC Prescriptive Worksheet (2010 edition) Zone 1 `1200 kwh LL:3d-6 \!y JUL U 1 2012 BY- -------------- - - - - -- 1.0 El 1.00 WSUEEP10-010 Copyright2010 Glazing Schedule Project Intiomlation Contact Into"ation Soundbuilt 1437 Conditioned Floor Area 14371 Sum of UA for Heating System Sizing F 56.5 Sum of All Glazing Areas From Belowl 134 Glazing to Floor Area Ratio 9.32% 602 7.2 Exception Ratio (not to exceed 1 %) F--7 Exterior Doors Plan Component Door Percent Width Height Glazing Door Door D-f I ie�'+"," rlIwari nt Fast inc' Feet 'n` Area Area UA V Vertical Glazing (Windows, Glazed doors using Exception 602.6 #1) Plan Component Glazing Ke1 Y ROOM Y ROOM BATH 2 WSEC Pnscrlptive Worksh"t (2010 Edition) .320 .320 Width Height Ot Feet mc" Feet "' INME©E Entry Door 0.200 1 3 6 e ©©ECE 20.0 4.0 Fire Door (exempt door =M■ 0.540 1 2 IN©E©E 6 17.8 9.6 EI©E =E =ME =■ NEME =E =MEMO =MEMO One Exempt Swinging Door < 24 S uam Feet =MEMO MMEMO Sum of Glazing Area, Door Area, and UA (do not include exempt door) Area Weighted U = UA/Area Sum of Area and UA for Heating system size only (include exempt door) 37.81 13.6 0.36 37.6 13,6 Vertical Glazing (Windows, Glazed doors using Exception 602.6 #1) Plan Component Glazing Ke1 Y ROOM Y ROOM BATH 2 WSEC Pnscrlptive Worksh"t (2010 Edition) .320 .320 Width Height Ot Feet mc" Feet "' INME©E M©EME ©©ECE =M■ =0 IN©E©E =©OI©E EI©E =E =ME =■ NEME =E =MEMO =MEMO =MEMO MMEMO INIONINE MINNIEN IEMEMO EIMENIO =MEMO' EIMEMO EIMEMO Elmoms Sum of Area and UA Area Weighted U = UA/Area Glazing 134.0 42.88 0.32 WSUEEPIO-010 Copyright 2010 Simple Heating System Size: Climate Zone 1 Project Information Soundbuilt 1437 Indoor Design Temperature 70 Outdoor Design Temperature 19 Design Temperature Difference (AT) AT . Indoor - Outdoor Design Temp 51 Conditioned Floor Area 948 Conditioned Volume 12,048 Glazing Copy Sum of UA from Glazing Schedule I 56 Attic U- Factor X Area R-49 0.027 792 R -38 Advanced 0.026 Single Rafter or Joist Vaulted Ceilings U- Factor X R -38 Vented 0.027 E] Above Grade Walls X Area U- Factor R -21 0.056 1658 Floors X Area U- Factor R -30 0.029 714 Below Grade Walls X Area U- Factor 2' Depth Walls 0.042 3.5' Depth Walls 0.041 7' De th Walls 0.037 Slab Below Grade X Length F- factor 2' Depth 0.59 3.5' Depth U.b4 7' De th _ Slab on Grade F- Factor X R -10 2' perimeter 0.54 R -10 Full - Heated 0.55 Sum of UA Envelope Heat Load Sum of UA X AT Air Leakage Heat Load ((Volume X 0.8) X AT) X .018)) Building Design Heat Load Contact Information IS UA 21.4 = UA UA _ 92.8 = UA 20.7 UA = UA UA 191 F.---9-76-21 Btu / Hour 6636 Btu / Hour 16398 Btu / Hour Air Leakage + Envelope Heat Loss Building and Duct Heat Load 1.15 18858 Btu / Hour If ducts are located in unconditioned space. Sum of Building Heat Loss X 1.15 If ducts are located in conditioned space. Sum of Building Heat Loss X 1 Maximum Heat Equipment Output Building and Duct Heat Loss X 1.50 150% 28287 Btu /Hour WSEC Prescriptive Worksheet (2010 Edition) WSUEEPIO -010 Copyright 2010 � _� 3 a � F *y'� . �i.� . � � l 7 ' ; ::,s• �'i�;. . �" .'� � � .� i � . Duct Leakage Affdavit Permit#: __��'"' ! � � ��f� House address or Iot number: �„ �, �,�(rj (,_((�(o City: _ �l�C,.-d'1/� Zip: . Corrd. Floor Area (ft2): /� �}�� Source (circle one): Plans Estimated Measured I:: ❑ Duct tightness testing is not required for this resi ence per exceptions listed at the end of thts document Air Handler in conditioned space?� �es no Air Handler present during test? yes 0 no , Circle Test Method: Leakage to Outside otal Leakage Maximum duct/eakage: . Post Construction,total duc#leakage: (f�oor area x.08)= CFM@25 Pa Post Construction, leakage to outdoors: (floor area x.06)= CFM@25 Pa � Rough-�n,total duct leakage with air handler Instalied: (floor area x.06) _�CFM@25 Pa • Rough-�n,total duct leakage with air handler not installed: (floor area x.04) = CFM@25 Pa Test Result: � � CFM@25Pa ,. �� . Ring (circle one if applicable): Open 1 2 �� 3 Duct Tester Location: �� V't' Pressure Tap Location: � � •� I cErtify that these duct leakage rates are accurate and determined using standard duct testing protocai. Company Name:�. " '' "�'` �'�;�, Technician: �.�.,��,.� Technician Signature� .. :�. ,�, Date:�*- � -1 Phone Number:���,��� Washington State Energ�Code referenca: 503.10.3 Sealing.Alt ducts,air handlers,filter boxes,and building cavities used as ducts shali be sealed.Joints and seams shall comply with Section M1601.3 of the lntemational Residential Code or 603.9 of the lntemational Mechanica/Code. �uct tfghtness testing shall be '� �, conducted to verifij that the ducts are sealed.A signed affidavit documenting the test results shall be provided to the jurisdictlon having authority by the testing agent.When required by the huiiding o�cial,the test shall be conducted in the presence of department staff. Exc�ptions: 1. Duct tightness test is not required if the air hand�er and all ducts are located within conditioned space. 2. Duct testing is not required if the furnace is a nondireci vent type combustion applianca installed in an uncondiiioned space. A maximum of si;:feet oT connected ductwqrlc in the unconditioned space is allowed.All additional supply and retum ducts { 4.....ia4' a'iia'+�v�:vJ�u�(li ti`T�CvRC�ItIC�I°G{8Cc'fC�, Dur„S OUt°IG�a Lhe cC('�j{jC(;,^G��r,cC3 S�lc^:���P,S°^�:�!i t:.�j!;��!n�afjC;��no�1"�.�epal?n'r anri insulated on the e:<terior vvith R-8 insufation for above grade ducts and P.-5�vater resistant insulation when within a slab or earth. �-��o i�G,Zy� Duct testing Calculator (New Construction) House address or lot#: ��; ��. �_�� ConditionedFloorArea: ��� -7 Duct tester location: ��- �� . ._ Pressure tap location: ���;- Ring (if applicable): open 1 2 3 � " At Rough-in (Total leakage) Test Method & Test2 Calculated Stand"aFdl� CFMu• Target Air Handler Present .06 X CFA<_ CFM <_6 CFMZS per 100 sf of CFA 25 Air Handler not Present - 5 4 CFMZS per 100 sf of CFA .04 X CFA� CFMZS Post Construction Test Method & Test2 Calculated Standardl CFM25 Target Air Handler Present(TotaF Leakagej � .08 X CFA S � .CFMzs 5 8 CFM25 per 100 sf of CFA • Air Handler Present(Leakage to Exterior) ,06 X CFA 5 CFMu <_6 CFMZS per 100 sf of CFA 1. Test results must comply with one of the Standards options. 2. Test CFM,S must be equal to or fess than the calculated target. . � Air Leakage testing Calculator(B/ower poor Test) Standard Tested CFM50 Calculated Test Result � ((�� CFM50 X 0.055)=(�.�?CFA X 144})=SLA 0.0003o s�► ��� �`• divided by �92 �= gLq SLA=C)C��Z Glossary ' Rough-In: After installation of the complete air distribution system but before installation of insulation and sheet rock. Allows for access to all duct seams and connections for re-evaluation of seal integrity if standard is not met in intitial test. Post Construction: At or near final inspection. The home must be complete enough to pressurize the home to 25 pa. Total Leakage: Aggregation of the entire systems duct leakage in a duct test. ' Leakage to Fxterior: Aggregation of all duct system leaks to the exterior of the CFA in a duct test. CFA: Conditioned floor area CFMu: Cubic feet per minute of air leakage at 25 pascals of pressure �FMso: Cubic feet per minute of air leakage at 50 pascals of pressure Pasca!(pa): Unit of pressure — SLA: Specific leakage area � U � � M � f` �--- � M O � +� � N � � � Q � yJ N N � � � � � � � � Q � � � c, o � � U N � '� � � $� � � � U O >+ � � V � � � � � C � > � Z � V � � q � � � � �� � � � c � � a � � � � � � � m � � � � � � � o � O � N ti a L � � � '� N O � a � C p � �fJ � � q � o � �� � � � ca ,� � � � � �! •� •,� Z U M �3 � a� r- � r� J J M V L i � � � � � (B �� '� � Z oQ �' � � L N � � � � � o � U � �i V M a. C� Q-o � � X J N � � O •N c� M j m } ON � Q (/� N � � O � � � � � � N Q U Q � a`� � Q C� cn � o � � � � cn Z f— � � � �, � -a o . . �� N ;� ,cQ a � � � � J U � U �1 « � (� � � � � � � � x F � � z Q � Y � U � �� � � � � � � N � � ��'� m O O m �' Q u) 00