Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
20120250 Permit Pkg 08202012
City of Yelm Community Development Department Building Division Phone: (360) 458-8407 Fax: (360) 458-3144 Applicant: Name: SOUNDBUILT NW LLC Address: PO BOX 73790 PUYALLUP WA 98373 Property Information Permit No.: 20120250 Issue Date: 8/20/2012 (Work must be completed within 180 days) Phone: 253 - 848 -0820 Site Address: 14427 LOCKWOOD LN SE 107 Owner: SOUNDBUILT NW LLC Assessor Parcel No.: 78640110700 Subdivision: TAHOMA TERRA Lot: 107 Contractor Information: Name: SOUNDBUILT NW LLC Phone: Address: PO BOX 73790 PUYALLUP WA 98373 Contractor License No.: Expires: 0 /00 /0000 Project Information: Project: NEW RESIDENTIAL BUILDING Description of Work: LOT 107, PLAN 997 Sq. Ft. per Floor: First 997 Heat Type (Electric, Gas, Other): Second Third Garage 327 Basement Fees: Item Contractor Fees NEW RESIDENTIAL BUILDING SOUNDBUILT NW LLC $12,256.73 MECHANICAL SOUND HEATING & AC $ 71.75 PLUMBING RAINIER VIEW ROOTER $ 90.00 TOTAL FEES: $ 12,418.48 Applicant's Affidavit: I certify that I have read and examined the information contained within the application and know the same to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of Yelm regulations including those governing zoning and land subdivision, and in addition, all covenants, easements and restrictions of record. If applying as a contractor, I further certify that I am currently registered in the State of Washiggton. Date K -d7/- Firth p elAa 14 -XI, W - OFFICIAL USE ONLY # Sets of Prints: Final Inspection: Date: By: TRAN: 33.0000 BUILDING PERMITS 20120247 12,754.66CR SOUNDBUILT NW LLC 14439 LOCKWOOD LN SE 105 BLD -REST 121558.91CR MECH 84.75CR PL 111.000R TRAN: 33.0000 BUILDING PERMITS 20120249 12,873.94CR SOUNDBUILT NW LLC 14433 LOCKWOOD LN SE 106 BLD -RES1 12,678.19CR MECH 84.75CR PL 111.000R TRAN: 33.0000 BUILDING PERMITS 20120250 12,418.48CR SOUNDBUILT NW LLC 14427 LOCKWOOD LN SE 107 BLD -RE31 12,256.73CR MECH 71.75CR PL 90.0008 TRAN: 33.0000 BUILDING PERMITS 20120251 12,754,66CR SOUNDBUILT NW LLC 14421 LOCKWOOD LN SE 108 BLD -RES1 12,558.9iCR MECH 84.75CR PL 111-OOCR TENDERED: 77,875,69 CHECK APPLIED: 77,875.69- CHANGE: D,00 City of fell (36 ) 458 -8402 REC #: 00103431 8/20/2012 1:38 PM OPER: CO TERM: 001 REF #: 14197 TRAN: 33.0000 BUILDING PERMITS 20120208 153.25CR SOUND BUILT HOMES, INC. 9979 DOTSON ST SE 90 BLD -RES2 153.25CR TRAN: 33,0000 BUILDING PERMITS 20120209 153.25CR SOUNDBUILT NW LLC 9973 DOTSON ST SE 89 BLD -RES2 153.25CR TRAN: 33.0000 BUILDING PERMITS 20120223 153.25CR SOUNDBUILT NW LLC 10012 JENSEN OR SE 54 BLD -RES2 153-25CR TRAN: 33.0000 BUILDING PERMITS 20120245 13,740.26CR SOUNDBUILT NW LLC 9980 JENSEN OR SE 56 BLD -RES1 13,537,01CR MECH 78.25CR PL 125.000R TRAN: 33.0000 BUILDING PERMITS 20120246 12,873.94CR SOUNDBUILT NW LLC 14445 LOCKWOOD LN SE 104 BLD -RESI 12,678.19CR MECH 84.75CR PL 111.000R 2jfqzA Z4:-- D CITY OF YELM RESIDENTIAL BUILDING PERMIT APPLICATION FORM Project Address:) -1—u 1 IkLlbij lid ei� Parcel #: r7 90 0 NO-700 Subdivision 111d ft krfO, Lot *.JD 2_ Plan #:- 997 a Zoning: New Construction ❑ Re -Model / Re -Roof / Addition Ei Home Occupation Sign Plumbing Mechanical ❑ Mobile / Manufactured Home Placement _ Other Project Description/Scope rof.-Woorrk:4 �1�1 �� {�t°Lt✓ ���✓IG/�° CfLyUW lf�Yf /C Project Value: l (� Building Area (sq. ft) 1rt Floor 1 2n0 Floor Garage Deck Basement Carport Patio # Bedrooms Z # Bathrooms, Heating GAS /OTHER or E ECTRIC (Circle One) Are there any environmentally sensitive areas located on the parcel? D H yes, a completed environmental Checklist must accompany permit application. A66RFScX 75790 EMAIL Ilk Srxvt .iLt 7'-S ( . CITY yatw STATE'.'.L_i ZIP ?7 TELEPHONE 953 - 848 -GS21 vt ;Weer LICENSE # ADDRESS EMAIL Sc4a-cnainecr5 dw<gs •ud CITY >'[ ckDiAI .,.a STATE ,. A ZI 4G'c/c TELEPH E 3r.0- Yn - /0/7 bu f N L\- TELEPHONE 53- 9 -GBao ADDRESS k C o EMAIL 0 sour oil e5,cowt CITY STATE LJr) ZIP "i FAX -535- c3/ CONTRACTOR'S LICENSE # EXP DATE-761CITY LICENSE # h'cr, Icr) ✓ TELEPHONE .2,5-3- (0 ADDRESS ✓ 731970 EMAIL CITY k i- STATE-&�A ZIP 7 3 FAX >.5.3 - -1 3�T - CONTRA TOR' LICENSE #2d n I v 0 EXP DATE_CITY LICENSE # )0 4 (&C TELEPHONE .. 1 ADDRES b Sh If EMAIL X 53- 87S- c 28s CITY n STATE W ZIP_ FAX CONTRACTOR'S LICENSE ha Q11§ EXP DATE--CITY LICENSE # Copy of mitigation agreement with Yelm Community Schools, if applicable. I hereby eertify that the above Infonnatlon Is correct and that the eorrtr110tion on, and the occupancy and the use of the above described property will be In accordance with the Ism, Mee and regulations of the stab of Washington and the City of Yelm. 1OA? C,.(;)- T N -1a- Appliccnt's Signature Date Owner / Contractor ees Agent 1 ontractor's Agent (Please circle one.) All permits are non - transferable and Will expire If work authorized by such permit is not begun within 180 days of issuance, or if work is suspended or abandoned for a period of 180 days 105 Yelm Avenue 0 Yelm, WA 98597 www.cLyelm.wa.us III I LL:3 `L-' L-0 BY:--- (860) 458 -88,75 (860) 458 -8144 FAX LOT 3105 SF IMPERVIOUS AREA: ROOF AREA: 1444 SF DRIVEWAY, WALK & PATIO AREA; 280 SF 1724 SF p/" y g 7 SOUNDBUILT HOMES LOT 107 TOHOMA TERRA 14427 LOCKWOOD LN SE YELM WA. 98597 Parcel # 78640110700 1 STORY OPT. B PRIVATE ROAD 5 89 01045" E LOCKWOOD LANE SE SILT FENCE ow (TYP.) n o" in s z al Z w �K O �U ? I � ng N!, b F7 Lri APPROX. AREA TO BE 14 CLEARED.ALL EXPOSED SOILS WILL BE 5' MULCHED WHEN NOT 5 n BEING WORKED G SILT FENCE ,n (TYP.) n u1 � _ J DRY WELL PER APP Ov�I m THURSTAN COUNTY y+ z 997 PLAN m STANDARD O �_ 5' 00 5 SCALE I"=20' FILEw 10' BSBL D 10 20 40 ® r' 3 0 OPEN JAN 1-- yzy -sss� SPACE SEA D LINODENDRON FERA 0.42 AC y R /V� 5 MN. TRACT B LUIZ w 0 Preicriptive Energy Code Compliance for Single Family and Duplex Housing: Zone 1 Protect Information Contact Information Soundbuilt 997B This set of forms has been developed to assist permit applicants documenting compliance with the Washington State Energy Code, (2009 edition). This set is for structures built under the IRC and located in Climate Zone 1. The following forms provide much of the required documentation for plan review. The details noted here must also be shown on the drawings (WSEC 104.2). This form is not a substitute for the energy code itself. To obtain a copy of the energy code, go to the following web address. http: //www.energy,wsu.edu /code See WSEC table 6 -1 for footnotes Glazing scneouie ncrarnea m uocumem Does not apply. (SEE INSTRUCTIONS) Using Prescriptive Option III. All glazing and F] doors meet maximum U- factor. Alternate heating size method submitted. 0 Option I or II, Glazing to floor area limit (WSEC 602.7.2) ❑ Area weighted window, skylight or door U- factor (WSEC 602.7.2) ❑ As part of the heating system sizing calculation (IRC M1401.3 & WSEC 503.2.2) Radiant slab: ❑ R -10 foam insulation, continuous with thermal break (WSEC 502.1.4.9) Chapter 9 Options Total of 1 Credit Required nnf not Description 1a Glazing lb High Efficient HVAC Equipment 2 1c High Efficient HVAC Equipment 3 Wall`' Wall. int Wall- ext° Efficient Building Envelope 1 Slab Option Area": Glazing U-Factor Door° Ceiling" Vaulted Above I Below Below , Floor on 6 %of Floor U- Factor Large Dwelling Unit Ceiling Grade Grade Grade Grade Vertical Overhead R49 or R -21 R -21 R -10 (0)I 13% 0.34 0.50 0.20 R -38 R -38 TB R -10 R -30 2, Adv. Int." R49 or R -21 R -21 R -10 OIl 25% 0.32 0.50 0.20 R -38 R -38 TB R -10 R -30 Adv. Int.' R49 or R -21 R -21 R -10 DIII Unlimited 0.30 0.50 0.20 R -38 R -38 TB R -10 R -30 2, Adv. Int, See WSEC table 6 -1 for footnotes Glazing scneouie ncrarnea m uocumem Does not apply. (SEE INSTRUCTIONS) Using Prescriptive Option III. All glazing and F] doors meet maximum U- factor. Alternate heating size method submitted. 0 Option I or II, Glazing to floor area limit (WSEC 602.7.2) ❑ Area weighted window, skylight or door U- factor (WSEC 602.7.2) ❑ As part of the heating system sizing calculation (IRC M1401.3 & WSEC 503.2.2) Radiant slab: ❑ R -10 foam insulation, continuous with thermal break (WSEC 502.1.4.9) Chapter 9 Options Total of 1 Credit Required nnf not Description 1a [High Efficiency HVAC Equipment 1 lb High Efficient HVAC Equipment 2 1c High Efficient HVAC Equipment 3 2 High Efficient HVAC Distribution System 3a Efficient Building Envelope 1 3b Efficient Building Envelope 2 3c Super-Efficient Building Envelope 3 4a Air Leakage Control and Efficient Ventilation 4b jAdditional Air Leakage Control and Efficient Ventilation 5a Efficient Water Heating 5b High Effieciency Water Heating 6 Small Dwelling Unit 7 Large Dwelling Unit 8 Renewable Electric Energy Total Credits WSEC Prescriptive Worksheet (2010 edition) Zone 1 '1200 kwh °� I,IL�IyLaV !UL 3 1 2012 M 1.0 El El El El El El El El El El 1.00 WSUEEP10A10 Copyright2010 ' Glazirig Schedule Project Information Contact Information Soundbuilt 99713 Conditioned Floor Area 997 Sum of UA for Heating System Sizing 49.0 Sum of All Glazing Areas From Below 111 Glazing to Floor Area Ratio 11.08% 602.7.2 Exception Ratio (not to exceed 1 %)0 Exterior Doors Plan Component Door Percent Width Height Glazing Door Door ID Description Ref. U- factor Glazed Qt. Feet Inc' Feet1oc° Area Area UA Vertical Glazing (Windows, Glazed doors using Exception 602.6 #1) Plan Component Glazing e e- am . e Entry Door 'ee 0.200 r 1 3 6 e MMEME 200 40 - Fire Door (exempt door _ 0.540 1 2 e 6 ° 17.8 9.6 IMEMI� INEMENS =MEMO MMEME =MEMO One Exempt Swinging Door < 24 Square Feet INEMENO INEME� Sum of Glazing Area, Door Area, and UA (do not include exempt door) Area Weighted U = UA/Area Sum of Area and UA for Heating system size only (include exempt door) 37.8 13.6 0.36 37.8 13.6 Vertical Glazing (Windows, Glazed doors using Exception 602.6 #1) Plan Component Glazing e e- am . e - 'ee r mun, wres r MMEME _r - e-ee _ r e MMEME - : e-ee r MMEME IMEMI� INEMENS =MEMO MMEME =MEMO INEMENO INEME� ENMEMO MMEME MEMME MIMEME WSEC Prescriptive Worksheet (2010 Edition) Width Height Qt Feet I° °h Feet'"`" MMEME M MMEME ®�I MMEME EN©EMO MMEME MMEME IMEMI� INEMENS =MEMO MMEME =MEMO INEMENO INEME� ENMEMO MMEME MEMME MIMEME MEMENE =MEMO M-EEM M-EMO Sum of Area and UA Area Weighted U = UA/Area Glazing Area UA era M ®�I 110.51 35.36 0.32 WSUEEPIO-010 Copyright 2010 •SImpld Heating System Size: Climate Zone 1 Pro- ct Information Contact Information Soundbuilt 9970 Indoor Design Temperature 70 Outdoor Design Temperature 19 Design Temperature Difference (AT) AT = Indoor - Outdoor Design Temp 51 Conditioned Floor Area 997 Conditioned Volume 8,973 Glazing Copy Sum of UA from Glazing Schedule 49 Attic U- Factor X Area = UA R-49 0.027 997 26.9 R -38 Advanced 0.026 Single Rafter or Joist Vaulted Ceilings U- Factor X Area = UA R -38 Vented 0.027 Above Grade Walls U- Factor X Area = UA R -21 0.056 1203 67.4 Floors U- Factor X Area = UA R -30 0.029 997 28.9 Below Grade Walls U- Factor X Area = UA 2' Depth Walls 0.042 3.5' Depth Walls 0.041 7' Depth Walls 0.037 Slab Below Grade F- Factor X Len th = UA 2' Depth 0.59 3.5' Depth 0.64 7' Depth 0.57 Slab on Grade F- Factor X Len th = UA R -10 2' perimeter 0.54 R -10 Full - Heated 0.55 Sum of UA 172 Envelope Heat Load 8780 Btu / Hour Sum of UA X AT Air Leakage Heat Load 4942 Btu / Hour ((Volume X 0.8) X AT) X,01 8)) Building Design Heat Load 13722 Btu / Hour Air Leakage , Envelope Heat Loss Building and Duct Heat Load 1 15781 Btu / Hour If ducts are located in unconditioned space . Sum of Building Heat Loss X 1.15 If ducts are located in conditioned space: Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 150% 23671 Btu / Hour Building and Duct Heat Loss X 1.50 WSEC Prescriptive Worksheet (2010 Edition) WSUEEP10 -010 Copyright 2010 M Q O � N � tC) � � � } � ,,_, O� Q � � � � � � � � O 4> � w U•�N � � � � U � � � O � � � � a� � V �j � � � � o � � � � � -� a� q � Z :� � � � � � � o � � ��� ti � � � � � — � � � cm �3 o a� � � O � � � N O �' d� �� L � � � O � � � r \ � � � � � q � o � __ � � � � � � '" w � � cv � •� � M � � � � � J J M = � L �' p) p � � c� }' +� � � 'Q� � '� � F- rnQ � � � � � J � � � V � V O � � � M a � � o p � � � XJ � � Z .�n � J N � w O � N � m 1a,,, N � 0 J � (B � ° ° � ° g ° v ` a� � Q � .N � ti � o �-- � � � � Z O � . . cn � ..r 'a o � u� �. ,c6 � � � � J U "� V e � � � � � Z Q � Y c V � f+ ; � �. L c ca u� ca c � � � � � � �� � �ra m 0 0 m � Q ci� m ° `. � � Duct E.eaKage Affidavit Permit#: � ��- 0 �"'�� House address or!ot number: � � `t��^'1� j--�� ��� ---- City: �;�LW1 Z�p� Cond. Floor Area(ftZ}:_ �,�3� Source(circle one): Plans Estimated Measured ❑ Duct�ightness testing is not required for this residence per exceptions listed at the end of this document Air Handler in conditioned space? �i yes❑ no Air Handler present during test'? es❑no Circle Test Method: Leakage to Outside otal Leatcag , Maximum duct Ieakage: Post Construction,total duct leakage: (floor area x.08)= CFM@25 Pa Pos#Construction, leakag�to outdoors: (fioor area x A6)= C�M@25 Pa , Rough-In,ta#at duct leakag�with air handler(nstatfed: (floor area x .06)= L�.� CFM@25 Pa Rough-In,total duct Eeakage with air handler�ot instalted: (floor area x.04)= CFM@25 Pa Test Result:��CFM@25Pa Ring(arcle one if applicable): Open 1 2 3 Duct Tester Location: �x2-!� �11'� Pressure Tap Location: � � CC�� �-�'H" I certify that these duct leakage rates are accurate and determined using standard duct#esting protocoi. Company Name:w�,,R�_!� � �t 1►� Technician: 1�� Technician 5ignature• Date:�(�'�-�� ZPhone Number: ���`��� i i Washington State Energy Code reference; � 503.10.3 Saaling.A!I ducts,air handiers,fiEter boxes,a�d building cavities used as ducts shall be sealed.Joints and seams shall comply •� j with SecGon M1801.3 of the lntematfona!Reside�nfiai Code or 603.9 of the lntematfonal Mechanica!Code. Duct tightness testing shall be � conducted to verify that the ducts are sealed.A�igned aflidavit dxumentEng the test results shall be provided to the jurisdiclion having i authority by the testing agent.When required by the building official,the test shal!be conducced In the presence of deparlment staff. i Exceptions: 1.Duct tightness test is not requirec�if the air handler and all ducts are located within conditloned space. ; 2.Duct testing is not required if the fumace is a no�direct vent rype combustion appliance installed in an unc:onditioned space. A maximum of six feet of connected ductwork in the unconditioned spaCe Is allowed.All additianal suppfy and retum ducts i shall be within the conditioned space.Ducts outside the conditioned space shall be sealed with a mastic type duct sealant and ; insulated on the exterior with R-8 insulatlon for a6ove grade ducts and R-5 water resisiant insulation when within a slab or � earth. • � � y i �` . . .._` : � . ' . , • • , I.�t�tt tes#ir�� Cal�ula�r��(N�� Ca�ts�ruttiflnJ . . House address oc lat#: �,,,� , t-�6ru,A, _,2,r� �. .� p� Candi�ioned Ffoor Area; ��—� : . Ducttes�kerlocation: (=�,P,-�— /��� _ Pressure tap loc�tia�s �j,�s;- �J/� R��g{�f app��cabl�e}: open 1 2 3 � � ��-' � �At Raugh-�n (Tota� Leakage) � TeSt NI�thQd & Test2 . Calculated S�ka nr��t�cl l CFM�° �'a rget Air H�ndlet'Pt�sent . , 5 6 CFM�per�.00 sf af CFA A5 X CFA 5�,��CFM� • Air Handler�,F�esent • . S 4 CFM�per ZOQ s'F qf CFA . .a4 X---,—C�p�� CFM� ,, � Post Cor�s�rvc#ion � . Tesf Me��od & �Test2 Cakcrlated . ' Standard�' . CFM� Targ�t � Air Handte�P�eserrt�i'ota}Leakage} A8 X 5 8 CFM�per 1QQ sf of CFA � tFR 5..______�..CFM� .;4�r HandlerFresent(Leafc��e to Exter-ior) ,06 X CFA<_ <6 CFMZ5 per 100 sFo�CFA . --- --�---..�CFM� - 1: Test resu�ts rr�ust cqmPlY�h o�e of the Standards optlons. � 2: Test CFM�must 4�equal to aF Jess tt�an the plculatesi targ�t. • - .. , � _ . . - ���'l�+a�C��� t�s�i�a� �'a�c��a���(��t���er Dc����'e�) ' Testea J I Stanc}ard � Caicula�ed Test Res�lt � - � � C�M�o ; , . ({{�.�?cFnnSO x o.a�5a= G( � 9 7 CFA X 144})=SLA � a.00+o3a s� ��3C� � .. ; , � 1 J _ ���� diyided by ��3S�o�'_ g� ; I � S LA=�.<'x�Z-7 ' i . . I Glossary . . ` �t�ugh-tn: After lns�allation of the com�(ete air dis`�rib�tion systarn b�befare irssta;lation a�insalatlon and sheef roc;;. ,4i)o�r�s for � � access to afi duct searns and connections fo�rz-ev�IU'a�IQ�1 Oi 523I int�;rir�ii s�andarti is not mat ir�intitia!tast_ F�s�ta�sirvciian: ,�t or near finaJ Inspection. The home m��s�be co�r��lsz��noug;�to prpssurize t5e ham�*_a 2y pa, 1, 7�taJ L�a.�ca��:'.4ga;zAation of the entire sys=ms duci lea:cag2ln a duct test. • i i.=a:<a��ia�nria°; ,�.g�r��atic��Ur dII aUC s�stvm le�ks to�ha extzrfcr o�tha�F',in a�Lt�#test. i CFA: Conditioned floor area � ! 'Fi;�I�;; Cu�ie�ee�per minu�:�oT ai,iea4asn 7T_L�DCSC��S C:�(}���=�ra � _ �Fi4I,o: Cuhic feet per rnin�te of air lea�Cage at 50�ascafs o�pre�sure �a5Z3����}: UTllt 0��P2$j1J?c j � SL4: Speciftc lea:cage ar2a ' ' , i � � i