Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
20120274 Permit Pkg 09262012
City of Yelm Community Development Department Building Division Phone: (360) 458-8407 Fax: (360) 458-3144 Applicant: Name: SOUNDBUILT NW LLC Address: PO BOX 73790 PUYALLUP WA 98373 Property Information: Site Address: QQRR _IFNSFN f1R CF 5R Assessor Parcel No.: 78640105800 Contractor Information: Name: SOUNDBUILT NW LLC Address: PO BOX 73790 PUYALLUP WA 98373 Contractor License No.: Project Information: Project: NEW RESIDENTIAL BUILDING Description of Work: LOT 58, PLAN 1732 Sq. Ft. per floor: First Second Third Garage Basement Fees: Item NEW RESIDENTIAL BUILDING MECHANICAL PLUMBING Permit No.: 20120274 Issue Date: 9/2612012 (Work must be completed within 180 days) Phone: 253- 848 -0820 Owner: SOUNDBUILT NW LLC Subdivision: TAHOMA TERRA Lot: 58 Phone: Expires: 0 /00 /0000 1732 Heat Type (Electric, Gas, Other): GAS 421 Contractor Fees SOUNDBUILT NW LLC $12,892.89 SOUND HEATING 8 AC $ 71.75 RAINIER VIEW ROOTER $ 104.00 TOTAL FEES: $ 13,068.64 Applicant's Affidavit: I certify that I have read and examined the information contained within the application and know the same to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of Yelm regulations including those governing zoning and land subdivision, and in addition, all covenants, easements and restrictions of record. If applying as a contractor, I further certify that I am currently registered in the State of Washington. /I Signature �� Date OFFICIAL USE ONLY # Sets of Prints: Final Inspection: Date: By: City of Veli (36 ) 458 -8402 REC #: 00106305 9/26/2012 2:05 PM OPER: CO TERM: 001 REF #: 14465 TRAN: 33,0000 BUILDING PERMITS 20120245 23.85CR SOUNDBUILT NW LLC 9980 JENSEN DR SE 56 BLD -RES1 23.85CR TRAN: 33,0000 BUILDING PERMITS 20120280 14,660,08CR SOUNDBUILT NW LLC 9947 JENSEN DR SE 57 BLD -RES1 14,456.83CR MECH 78.25CR PL 125.000R TRAN: 33.0000 BUILDING PERMITS 20120276 13,542.41CR SOUNDBUILT NW LLC 9956 JENSEN DR SE 60 BLD -RES1 13,346,16CR MECH 78.25CR PL 118.00CR TRAN: 33,0000 BUILDING PERMITS 20120275 13,804.82CR SOUNDBUILT NW LLC 9962 JENSEN DR SE 59 BLD -RES1 13,608.57CR MECH 78.25CR PL 118.00CR TRAN: 33.0000 BUILDING PERMITS 20120274 13,068.64CR SOUNDBUILT NW LLC 9968 JENSEN DR SE 58 BLD -RES1 12,892.89CR MECH 71.75CR PL 104.000R TENDERED: 55,099.80 CHECK APPLIED: 55,099.80- CHANGE: 0.00 iR CITY OF YELM Z7 cI© RESIDENTIAL BUILDING PERMIT APPLICATION FORM Project Address: I l (a r knurl 7Y,z., Parcel # 7Rl„9 ©105 S 0C SubdMsion:L,t 1U2Cc TCYf'LL W*. `7 Plan* 1)2, Zoning: New Construction ❑ Re -Model / Re -Roof / Addition ❑ Home Occupation Sign p Plumbing ❑ Mechanical ❑ Mobile / Manufactured Home Placement ❑ Other Project DescriptioNSoope of Work: EU'llcL neW 51na L Qty ilu h Dh1G Project Value: Building Area (sq. ft) le Floor ' 4 2n0 Floor Garage ` L ; Deck Basement Carport Patio # Bedrooms . i # Bathrooms Heating S(OTHER or ELECTRIC (Circle One) Are there any environmentally sensitive areas located on the parcel? /u N yes, a completed environmental checklist must accompany permit application. r LICENSE # ADDRESS L2,MT Main EMAIL lam. in lend9larKOICriSCDNt CITY .a+nt_L STATE �-ZIP UiQ TELEPHONE - Aa I - 533:1 •• m r TELEPHONE ADDR -� EMAIL CITY STATE ZIP FAX CONTRACTOR'S LICENSE # P DATE CITY LICENSE # flir TELEPHONE » Q-976'-1%358 ADDRESS EMAIL CITY STATE ZIP Q S ,Q37 FAX CONTRA TORS LICENSE EXP DA CITY LICENSE # Copy of mitigation agreement with Yelm Community Schools, if applicable. I Iranby qW t art aw above iMonnWon is correct end Ow the construction on, and the oceupOnCy and the ire of the all, va dsprwN popery will be in ac ordanco vrM the Ian, rules and regulations of the star rtftl M' - kpsn and ar City of Ystm. APPI Signature Dab Owner I r I Owner's Agent I Contractor's Agent (Please circle one.) All permits are non - transferable and will expire If work authortzsd by such permit is not begun within 180 days of Issuance, or H work In suspended or abandoned for a period of 180 days 101 Yebe Avenue Wed r+ «r v+•+ «. Yslnr, WA 99197 U c^ 8 -23 -12 JF W K UI O D me 0r -u Zl -f —m.0 00(n D:U �m §AO O V T �r'D DTl mm WI m p z l m D Z x Z O 00 O "i m m pm _ In < r fTl n m - i ac< _ 1 20' 6SLI_ co N I cn I! PROPOSLp 1732 plan 0 FILE AP ROYED z 7 � A A O N 2 Dmo - D A -G ! m g D m r i nn I I C1 I N 0 � 0 VI h r m u' r.; a _ 1 20' 6SLI_ co N I cn I! PROPOSLp 1732 plan 0 FILE AP ROYED sOY ROCK O CO,NSTRUCTIO (.O — LNTRANCE O C] O-) ---- _ " ---- i C SIUC WALK m m c- 00 SILT FINCF 10 L3I - - -" —CURB CD Z44-- G INSTAL_ -ED AS (n APPROVLD BY CITY- O J C m Q INSP[ C 1 OR KRAUTER VESUVIUS PLUM U� oc) D 2' CAI_ MIN, M 0-) - Ul O c) O D -D 00 JENSEN DRIVE SE ' ° U, oT - D oc) > U) —{ PI 0 CL �J c- C� U� � A A Dmo - D A D;C m m g D m r � N A z N � n sOY ROCK O CO,NSTRUCTIO (.O — LNTRANCE O C] O-) ---- _ " ---- i C SIUC WALK m m c- 00 SILT FINCF 10 L3I - - -" —CURB CD Z44-- G INSTAL_ -ED AS (n APPROVLD BY CITY- O J C m Q INSP[ C 1 OR KRAUTER VESUVIUS PLUM U� oc) D 2' CAI_ MIN, M 0-) - Ul O c) O D -D 00 JENSEN DRIVE SE ' ° U, oT - D oc) > U) —{ PI 0 CL �J c- C� U� Prescriptive Energy Code Compliance for Single Family and Duplex Housing: Zone 1 Project Information Contact Information ILl-1732 This set of forms has been developed to assist permit applicants documenting compliance with the Washington State Energy Code, (2009 edition). This set is for structures built under the IRC and located in Climate Zone 1. The following forms provide much of the required documentation for plan review. The details noted here must also be shown on the drawings (WSEC 104.2). This form is not a substitute for the energy code itself. To obtain a copy of the energy code, go to the following web address. hftp: / /www.energy.wsu.edu /code See WSEC table 6 -1 for footnotes Does not apply. (SEE INSTRUCTIONS) Using Prescriptive Option III. All glazing and F1 doors meet maximum U- factor. Alternate heating size method submitted. Fil Option I or II, Glazing to floor area limit (WSEC 602.7.2) ❑ Area weighted window, skylight or door U- factor (WSEC 602.7.2) ❑ As part of the heating system sizing calculation (IRC M1401.3 & WSEC 503.2.2) Radiant slab: ❑ R -10 foam insulation, continuous with thermal break (WSEC 502.1.4.9) Chapter 9 Options Total of 1 Credit Required Opt. Opt. Description 1a Glazing o Glazing U- Factor Door 9 1c Vaulted Wall Z Wall- int° Wall- ext' Efficient Building Envelope 1 Slab' Option Area Super-Efficient Building Envelope 3 4a Ceiling 3 Above Below Below Floor' on Vertical Overhead" 7 % of Floor U- Factor Renewable Electric Energy Ceiling I Grade Grade Grade Grade R -49 or I 13% 034 0.50 0.20 R -38 R -38 R -21 R -21 R -10 R -30 R -10 Int.7 TB 2, Adv. R -49 or D II 25% 0.32 0.50 0.20 R -38 R -38 B -21 R -21 R -10 R -30 R -10 Adv. 7 Int. TB 2' R -49 or ❑ III Unlimited 0.30 0.50 0.20 R -38 R -38 R -21 R -21 R -10 R -30 R -10 Adv. Int.' TB 21 See WSEC table 6 -1 for footnotes Does not apply. (SEE INSTRUCTIONS) Using Prescriptive Option III. All glazing and F1 doors meet maximum U- factor. Alternate heating size method submitted. Fil Option I or II, Glazing to floor area limit (WSEC 602.7.2) ❑ Area weighted window, skylight or door U- factor (WSEC 602.7.2) ❑ As part of the heating system sizing calculation (IRC M1401.3 & WSEC 503.2.2) Radiant slab: ❑ R -10 foam insulation, continuous with thermal break (WSEC 502.1.4.9) Chapter 9 Options Total of 1 Credit Required Opt. Opt. Description 1a High Efficiency HVAC Equipment 1 lb High Efficiency HVAC Equipment 2 1c High Efficiency HVAC Equipment 3 2 High Efficiency HVAC Distribution System 3a Efficient Building Envelope 1 3b Efficient Building Envelope 2 3c Super-Efficient Building Envelope 3 4a Air Leakage Control and Efficient Ventilation 41b Additional Air Leakage Control and Efficient Ventilation 5a Efficient Water Heating 5b High Eff ieciency Water Heating 6 Small Dwelling Unit 7 Large Dwelling Unit 8 Renewable Electric Energy Total Credits WSEC Prescriptive Worksheet (2010 edition) Zone 1 *1200 kwh BY- -------------- - - - - -- 1.0 0 El El El El El El El El El El El 1.00 WSUEEP10 -010 Copyright 2010 Glazing Schedule Project Information Contact Information L1 -1732 Conditioned Floor Area 1732 Sum of UA for Heating System Sizing 111.5 Sum of All Glazing Areas From Below 306 Glazing to Floor Area Ratio 17.67% 602.7.2 Exception Ratio (not to exceed 1 %) Exterior Doors Plan Component Door Percent Width Height Glazing Door Door ID Description Ref 11- factnr ('la7prl nt Foci Inch goof Inch Arco 4'm I IA Vertical Glazing (Windows, Glazed doors using Exception 602.6 #1) Plan Component Glazing ID Description Ref. U- factor Entry Door ENTRY 0.200 0.320 1 3 6 s BEDROOM 3 20.0 4.0 Fire Door (exempt door ) M©NMO 0.540 1 2 9 6 a 0.320 MMEMN GREAT ROOM 0.320 MASTER BEDROOM 0.320 MASTER BEDROOM MMEME 0.320 MASTER BATH 0.320 M©UME Elf One Exempt Swinging Door < 24 Square Feet mMEME MEMEM Sum of Glazing Area, Door Area, and UA (do not include exempt door) Area Weighted U = UA/Area Sum of Area and UA for Heating system size only (include exempt door) 37.8 q13 37.8 Vertical Glazing (Windows, Glazed doors using Exception 602.6 #1) Plan Component Glazing ID Description Ref. U- factor ENTRY 0.320 MMEME ENTRY 0.320 BEDROOM 3 0.320 BEDROOM 2 M©NMO 0.320 KITCHEN 0.320 DINING 0.320 MMEMN GREAT ROOM 0.320 MASTER BEDROOM 0.320 MASTER BEDROOM MMEME 0.320 MASTER BATH 0.320 M©UME MEMEM mMEME MEMEM NEEMEM EMMEM EMMUM MEMEM WSEC Prescriptive Worksheet (2010 Edition) Width Height Ot. Feet Inch Feet Inch MMEME MMEME MMEME M©NMO MMEME MMEMN MMEME MMEME ©©O©N M©UME MEMEM mMEME MEMEM NEEMEM EMMEM EMMUM MEMEM MMEME IMEEME Elm��� IN Sum of Area and UA Area Weighted U = UA/Area Glazing Area UA 306.01 97.92 0.32 WSUEEP10 -010 Copyright 2010 Overhead Glazing Plan Component Nei Glazing Width Height Qt. Feet Inch Feet Inch Sum of Area and UA Area Weighted U = UA/Area Doube Glazed Garden Windows Section 602.7.2 Exception Plan Component Width Height ID Description Qt. Feet Inch Feet Inch Sum of Area Sum of Area X 3 (This total is automatically included in the glazing area total.) Glazing UA for Heating System Size Only = Area X 0.63 WSEC Prescriptive Worksheet (2010 Edition) Area UA WSUEEP10 -010 Copyright 2010 Simple Heating System Size: Climate Zone 1 ' Project information Contact Information L'1 -1732 Indoor Design Temperature 70 Outdoor Design Temperature 19 Design Temperature Difference (OT) AT = Indoor - Outdoor Design Temp 51 Conditioned Floor Area 1732 Conditioned Volume 17,267 Glazing Copy Sum of UA from Glazing Schedule 112 Attic U- Factor X Area R -49 0.027 1732 R -38 Advanced 0.026 Single Rafter or Joist Vaulted Ceilings U- Factor X Area R -38 Vented 0.027 Above Grade Walls X Area U- Factor R -21 0.056 F 1532 Floors X Area U- Factor R -30 0.029 1732 Below Grade Walls X Area U- Factor 2' Depth Walls 0.042 3.5' Depth Walls 0.041 7' Depth Walls 0.037 Slab Below Grade X Len th F- Factor 2' Depth 0.59 3.5' Depth 0.64 7' Depth 0.57 Slab on Grade F- Factor X Len th R -10 2' perimeter 0.54 R -10 Full - Heated 0.55 Sum of UA Envelope Heat Load Sum of UA X AT Air Leakage Heat Load ((Volume X 0.6) X 4T) X.01 8)) UA 46.8 = UA UA 85.8 = UA 50.2 UA = UA = UA 294 15010 Btu / Hour 9511 Btu / Hour Building Design Heat Load 24520 Btu / Hour Air Leakage + Envelope Heat Loss Building and Duct Heat Load 715 28198 Btu / Hour If ducts are located in unconditioned space: Sum of Building Heat Loss X 1.15 If ducts are located in conditioned space: Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 150% 42297 Btu / Hour Building and Duct Heat Loss X 1.50 WSEC Prescriptive Worksheet (2010 Edition) WSUEEPIO -010 Copyright2010 :.a �i '" �.��- -- F �i � s 1��.� .� � � � y�� � 7 j., �■ :� _ .'_P . yv... "i.} �i�c�5 'l.,, D ,7 i �' '�i1", �-` -� � �..� Duct L�akage Affidavit � Permit#: _ <i� � � ��2-�� House address or Iot number. ��` �Y� � "'�_���'°��'-�' �p � t. City: _ ' vri�...Y!'� ZiP� CoRd. Ftoor Area(ft2): I. �`3 Z So�rce(circie one): Pians Estimated Measured , I,, � ❑ Duct tightness testing is not required for this resi l ence per exceptions listed at the end of thls document Air Handler in conditioned space?p �res no I� Alr Handler present during test? yes[Q no i Circfe Test Method: Leakage to Outsidel otal Leakage _ Maximum duc!leakage: � , • Post Censtrucfion,total duct leakage: (fl,aor area�C.08)=TCFM@25 Pa � - Post Constructlon, leakage to outdoors: (ffoor are�a x.06)= CFM@25 Pa . , Rough-In,total duct leakage wit}� air handler installed: (fioor area x.06) _�{�CFM@25 Pa • j . -. . . . _ . , Rough-!n,total duct leakage with air handler not tnstalled: (floor area x.04) = w CFM@25 Pa � Test Resuit: CFM@25Pa , ., "' „ Ring(circle one if app(icable}: Open 1 2 �• 3 Duct Tester Location:. � I Pressure Tap Location: �}, � , ; .. I c�rtifiy that these ducf leakage rates are acc�rate and determined using standard duct testing protocal. Company Name:��`� � $�� � ��,�I Technician:��3�� � . .. Technician Signature=,. ., ,� Date:l D'"� �.��j Phone Number.���,�'�� Washington State Energ�Code referanca: 503.�0.3 Sealing.All ducts,air handlers,filter boxes,and building c�avitles used as ducts shall be sealed.Joints and seams shall comply • with Section M16o1.3 of the Intema�ona!Residentla/Code or 603.�of the Intematlona/Mechanical Code. Ouct ttghtness test(ng shall be i'�� conducted to verify that the ducts are sealed.A signed affidavit doc�menting the test results shall be provided to the jurisdiction having authority by the testing agent When required by the building official�the test shail be conducted in the presence of depar4nent staff. Excaptions: 1. Duct tightness test is not required if the air handler�nd all ducts are located within conditioned space. 2.Duct testing is not required if the fumace is a nonditIect ve[lt rype combustion appfiance installed in an unconditioned space. A maximum of six feet of connected ductworlc in the ut�conditioned space is ailowed.All additional supply and retum ducts ... y.".,__y.----,--- �.,ico-t�} . _ _ �.. 1.�.",'.:�...:w.�--.. a C �y 111�� o.lo th� aa � nn c oleni� �i ia�f u�. �Viuifl i uic�vRG�I� JI+C ET�CI'G(+��r..�„NF�C h�.�� S•���•�{:;">I.,�,.lT1�..�IC rJ,...G�L'C:,.°......�,.�!7C{ insulated on ihe e:derior with R-8 insulation for abo ie grade ducts and P,-5 water resistant insulaUon when within a slab or earth. i � � � �O Z. `7 � -- D��t t�sti�g Cal�ul�#�� j1�e� Co�stru�ti��J . House address or lot#: j �: �, Conditioned Floor Area: � -Z �Z Duct tester location: �� � _ Pressure tap (ocation: '�' � Ring (if applicable): Open 1 2 3 � ���' •� � At Raug}�-in (Tota� Lea�Cage) Test Method & Test� � Calculated Stand"aFCl1 CFM�• �Target Air Handter Present 5 6 CFM�per 100 sf of CFA .06 X_CFA 5 CFM� � Air Handler not Present � . _<4 CFM�per 100 sf of CFA . •�'�X_CFA�S CFM� � Post Co�st�uc#ion � � Test Mett�od & �Test� Calculated � Standardl CFM� Target �. Air Handler Present(Total•Leakag�) 5 8 CFM75 per 100 sf of CFA � '�$x �FQ� ' CFM� Air Handler Present(Leakage to Exterior) 5 6 CFM�per 100 sf of CFA .06 X CFA<_ CFM� - - 1. Test results must c�mpiy with one of the Standards options. ` 2. Test CFM�must be equal to or less tttan the ca(culater!targat. � � � A��L������ t�sti�� Ca�������-(��������r�� �'es#� Standard � � Test�d � � � C�MSa Cakulated Test Result � ' ' ( �� CFM50 X 0.055}=(���FA X 144))=SLA Q.00�3�fl Si.� ��7(� � . � �3_3 �;�,���a �,� �`�� 5� � ' s�,_�ac�.� ' ; Glossary . . Raug�a-tn: After installativn of the com�let�air distrib�*tion systarrr b!ut befa�a ins-���)ation oi insulation and shaet roc.'-.. �lla�,�s fos access to all duct szams and connections for re-e��aluatioa� of saa!intebrit��R�zndard is not rn2t in int;tial te�_ Ps�s���nsirv�3a�: At or ne�r final inspectio�. The hom�mus be comnlstz enoug�to��nssu�iz�t�te hsJ�T7�tp 25 ��. Ta�al Laa?ca;�: Agareaation of the entire systems duct iea;�age in a duct test. L°a'<age ia ExtnY3O�; I�COrEoction of al!duct system lealcs to tt��e��rier oa Lha CF,;in a dUCt task. ��A: Conditioned floor area ��`�,�: Cubic fee�aa�minute of air lea4aae at Z5 p�scals of pr=�:�;r� _ �.Pi`�1�o: Cubic feet per�ninute of air leakage at 50 pastals o�p���ure Pas�a�(�a): Unit of Qrassure — SLA: Specific lealcage area ' U � � � � N � � M N � �. � � � � L^` +� �� W � � � O � � � N � O U Q'o � V N ,� � � � � � � � N U O >+ � � � � � U � q � � � � ' Q Z a) ° '+� � � � V � � � � � � � �v � °' �� a�i � � � � � � � � � � � m c� � $� C.> ° N � O 'J � � c� 0 � •� � � o� �N � N � � o N � � � q �, �,-� � � � � � � � ,� "'' � CV •'J .�, V c� � � ai � � w J � � � � � � J � p � � � - � � '� � Z � Q � �� .� � � �Z � � � � o � U U � � f� � � � C O � Z � � � J N N W � �� cn 00 � m Q N M � � � (B � } � � � �' � rn � � � ° Z U Q � a`� � Q C� cn � � � H � � � � Z �' � . . � -a o �'`���.�1:E N � � � J � � .(B r U "a U � �Y Q � "� � N Q U � itt Z � O �" F�� � z Q � �C � � �(y W � � N � (a cn � c 3 r�+ � c c � E c� � '� �`�t�� m O O m � Q c� m