Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
20120275 Permit Pkg 09262012
City of Yelm Community Development Department Building Division Phone: (360) 458-8407 Fax: (360) 458-3144 Applicant: Name: SOUNDBUILT NW LLC Address: PO BOX 73790 PUYALLUP WA 98373 Property Information: Site Address: QQR9 - iFNSFN np SF FQ Permit No.: 20120275 Issue Date: 912612012 (Work must be completed within 180 days) Phone: 253 - 848 -0820 Owner: SOUNDBUILT NW LLC Assessor Parcel No.: 78640105900 Subdivision: TAHOMA TERRA Lot: 59 Contractor Information: Name: SOUNDBUILT NW LLC Address: PO BOX 73790 PUYALLUP WA 98373 Phone: Contractor License No.: Expires: 0 /00 /0000 Project Information: Project: NEW RESIDENTIAL BUILDING Description of Work: LOT 59, PLAN 2603 Sq. Ft. per floor: First 1262 Heat Type (Electric, Gas, Other): GAS Second 1341 Third Garage 414 Basement Fees: Item Contractor Fees NEW RESIDENTIAL BUILDING SOUNDBUILT NW LLC $13,608.57 MECHANICAL SOUND HEATING & AC $ 78.25 PLUMBING RAINIER VIEW ROOTER $ 118.00 TOTAL FEES: $ 13,804.82 Applicant's Affidavit: I certify that I have read and examined the information contained within the application and know the same to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of Yelm regulations including those governing zoning and land subdivision, and in addition, all covenants, easements and restrictions of record. If applying as a contractor, I further certify that I am currently registered in the State of Washingtyn. 9 -24 /Z Firm OFFICIAL USE ONLY # Sets of Prints: Final Inspection: Date: By: City of Ni (36 ) 458 -8402 REC #: 00106305 9/26/2012 2:05 PM OPER: CO TERM: 001 REF #: 14465 TRAN: 33.0000 BUILDING PERMITS 20120245 23.85CR SOUNDBUILT NW LLC 9980 JENSEN DR SE 56 BLD -RES1 23.85CR TRAN: 33.0000 BUILDING PERMITS 20120280 14,660.08CR SOUNDBUILT NW LLC 9947 JENSEN DR SE 57 BLD -RES1 14,456.83CR MECH 78.25CR PL 125.000R TRAN: 33.0000 BUILDING PERMITS 20120276 13,542,41CR SOUNDBUILT NW LLC 9956 JENSEN OR SE 60 BLD -RES1 13,346,16CR MECH 78.25CR PL 118 -OOCR TRAN: 33.0000 BUILDING PERMITS 20120275 13,804.82CR SOUNDBUILT NW LLC 9962 JENSEN DR SE 59 BLD -RES1 13,608.57CR MECH 78.25CR PL 118.000R TRAN: 33.0000 BUILDING PERMITS 20120274 13,068.64CR SOUNDBUILT NW LLC 9968 JENSEN DR SE 58 BLD -RES1 12,892.89CR MECH 71,75CR PL 104.000R TENDERED: 55,099.80 CHECK APPLIED: 55,099.80- CHANGE: 0,00 CITY OF YELM 20 j 2•b2-7 S RESIDENTIAL BUILDING PERMIT APPLICATION FORM p Project Address: l t' �Ip 6,;� jffl l�:Yl Dr _y Parcel t. ' % LA 01 C S I Subdivision: I AjjI!/td MA, Lot #� -I Plank :'L t _" > Zoning: New Construction ❑ Re -Model I Re -Roof 1 Addition ❑ Home Occupation Sign ❑ Plumbing ❑ Mechanical ❑ Mobile / Manufactured Home Placement ❑ Other ProjedDeacnptioNScopeofWorkl,ilcL Mul SjlkJi' taMt�� %lOft1C Project Value: Building Area (sq. R) 1" Floor 2nd Floor Garage r Deck Basement_ Carport Patio # Bedroomaj # Bathrooms r• Heating(�OTHER o, r ELECTRIC (Circle One) Are there any environmentally sensitive areas located on the parcel? Jo H yea, a completed environmental checklist must accompany permit application. DWil LICENSE # ADDRESS 4i EMAIL 11�.rin lm,ds•tarlt t4 yiS Cowl CITY STATE ZIP x90 TELEPHONE - - S ?,4 r TELEPHONE - ADDR ESS r C EMAIL 1 r•corr, CITY �,y��STATE IP FAX CONTRA TOR'$S LICENSE *&&Ait = OC EXP DATE CITY LICENSE # Ric TELEPHONE1iS-47S�335� ADDRESS EMAIL CITY STATE [A�AA��ZIP 4?Q;[7S FAX CONTRACTOR'S LICENSE #1QNViAWAMfaQA EXP DAY31&CITY LICENSE # Copy of mitigation agreement with Yelm Community Schools, if applicable. I hMaby oaPoy slat ar above kftnvw on Y correct and tiun the constriction on, and the occupancy and the use of the above daaatlbM p-pulp wN be In accordance with the laws, rules and regulations of the $ofa of Washington and the CRY Of yak". Appillmnl' 84nature Data Owner 1 Contractor I Owner's Agent I Contractor's Agent (Please circle one.) All permits are non- transfsnble and wlil expire H work authorised by such permit Is not begun within 180 days of Issuance, or H work Is suspended or abandoned for a period of 180 days lU Yelm Avenue Wost _ - -- - _ _ _ ['!�� (80) 158-5885 Yehr% WA 88587 � � %7 L6 V/ �_ 1 (888) 588-5114 PAZ r•roro.ciyeGn.ros. ue n,jr 9 2012 LI M B-23-12 JE w <Wo M SAO m�mx 0 ;u m T CC) ornm m x vo V) Lu M cf) I I -,I m O m > C Z ;D O U1 > -irq X > O C Z Ln N) C.D 5' 5 (A KRALITER VESUVIUS PLUM 2" CAL MIN JE OFILE 24730 pion plan 26030 41 CA 5' 15' Du nip - : 4 0' L-_ 5' 5 (A KRALITER VESUVIUS PLUM 2" CAL MIN JE OFILE 24730 pion plan 26030 41 CA 5' 15' c 0 UD C-- 0 -L K F-F-1 ) Du nip - 0 ROCK CK LN� 'R.TION Dan C) �o (.(J U) ILI, N) c 0 UD C-- 0 -L K F-F-1 ) 0 ROCK CK LN� 'R.TION C) (.(J CNTRANCE N) V) c- m SILT FENCE 10 BE 0 J cn 0 INSTAH FD AS API-)ROVED BY CITY cf) M ()o > III �,L FFI -< 0-) - z INSPECTOR ---i N 0 LD 0 -0 o 00 5E > (*) —, 0 � —< < > &VE 7\ , U-I z > QD 111 W F-1-1 m c 0 UD C-- 0 -L K F-F-1 ) Pr�,scriptive Energy Code Compliance for Single Family and Duplex Housing: Zone 1 Protect Information Soundbuilt Homes 2603 -C Contact Information This set of forms has been developed to assist permit applicants documenting compliance with the Washington State Energy Code, (2009 edition) This set is for structures built under the IRC and located in Climate Zone 1 The following forms provide much of the required documentation for plan review. The details noted here must also be shown on the drawings (WSEC 104.2). This form is not a substitute for the energy code itself To obtain a copy of the energy code, go to the following web address http'Itwww energy wsu.edWcode See WSEC tabis 6-1 for footnotes ❑ Does not apply. (SEE INSTRUCTIONS) Using Prescriptive Option III. All glazing and doors meet maximum U- factor. Alternate heating size method submitted. 2 Option I or II, Glazing to floor area limit (WSEC 602.7.2) ❑ Area weighted window, skylight or door U- factor (WSEC 602.7.2) ❑ As part of the heating system sizing calculation (IRC M1401.3 & WSEC 503.2.2) Radiant slab: ❑ R -10 foam insulation, continuous with thermal break (WSEC 502.1.4.9) Chapter 8 Options Total of 1 Credit Required Opt Opt. Description 1a Glazing �� Glazing U- Factor Door ° 1c Vaulted Wall'- Wall- int Wall ext4 Efficient Building Envelope 1 Slab° Option Area Super-Efficient Building Envelope 3 U- Factor Ceiling2 � Ceiling Above Below Below Floors on Vertical Overhead 7 %of Floor 8 Renewable Electric Energy Grade Grade Grade Grade R-49 or R -21 R -21 R -10 Q 1 13% 0.34 0.50 0.20 R -38 R -38 R -10 R -30 Int.' TB 2, Adv. R49 or R -21 R -21 R -10 0 II 25% 0.32 0.50 0.20 R -38 R -38 R -10 R -30 Int. TB 2, Adv. R49 or R -21 R -21 R -10 III Unlimited 0.30 0.50 0.20 R -38 R -38 R -10 Int' TB Adv. See WSEC tabis 6-1 for footnotes ❑ Does not apply. (SEE INSTRUCTIONS) Using Prescriptive Option III. All glazing and doors meet maximum U- factor. Alternate heating size method submitted. 2 Option I or II, Glazing to floor area limit (WSEC 602.7.2) ❑ Area weighted window, skylight or door U- factor (WSEC 602.7.2) ❑ As part of the heating system sizing calculation (IRC M1401.3 & WSEC 503.2.2) Radiant slab: ❑ R -10 foam insulation, continuous with thermal break (WSEC 502.1.4.9) Chapter 8 Options Total of 1 Credit Required Opt Opt. Description 1a lHigh Efficiency HVAC Equipment 1 lb High Efficiency HVAC Equipment 2 1c High Efficiency HVAC Equipment 3 2 High Efficiency HVAC Distribution System 3a Efficient Building Envelope 1 3b Efficient Building Envelope 2 3c Super-Efficient Building Envelope 3 4a Air Leakage Control and Efficient Ventilation 4b Additional Air Leakage Control and Efficient Ventilation 5a Efficient Water Heabn 5b High Effieciency Water Heating 6 Small Dwelling Unit 7 Large Dwelling Unit 8 Renewable Electric Energy Total Credits WSEC Prescriptive Worksheet (2010 edition) Zone 1 M •1200 kWh 1.0 Q 1.00 WSUEEP10-010 Copyright 2010 IR Glazing Schedule Protect Information Contact Information 2603 -C Conditioned Floor Area 2598 Sum of UA for Heating System Sizing F 121 7 Sum of All Glazing Areas From Below 318 Glazing to Floor Area Ratio 12.24% 602.7.2 Exception Ratio (not to exceed 1 %)F--� Exterior Doors Plan Component Door Percent Width Height Glazing Door Door in nPer-rintion Ref U- factor Glazed Ot Feet'"`" Feet "`" Area Area UA Vertical Glazing (Windows, Glazed doors using Exception 602.6 #1) Plan Component Glazing Width Height ID Descriotion Ref. U- factor Qt. Feet'"`" Feet'"`" MILE Entry Door Ml 0.200 30.0 1 3 ' 61 11 _ 20.0 4.0 3.06 Fire Door (exempt door 0.540 .. 1 2 ° 6 IM 5.44 17.8 9.6 24.0 8.16 IM 3.06 _e t M©EMN IM IM IM MMEM: IM One Exempt Swnginq Door a 24 Square Feet _ e =MEMO IM Sum of Glazing Area, Door Area, and UA (do not include exempt door) Area Weighted U = UAiArea Sum of Area and UA for Heating system size only (include exempt door) 1 37.81 13.6 0.36 1 1 37,81 1 1 r Vertical Glazing (Windows, Glazed doors using Exception 602.6 #1) Plan Component Glazing Width Height ID Descriotion Ref. U- factor Qt. Feet'"`" Feet'"`" MILE 2.04 Ml '' 30.0 • �' ' IM 13.60 _ e m 3.06 12.0 IM .. _ r INMEMO, 5.44 IM 5.44 16.0 ' ININIMINNINE 24.0 8.16 IM 3.06 _e t M©EMN IM IM IM MMEM: IM .:... _ e =MEMO IM MMEME =MNIMO MMEME __ MMEME WSEC Proscriptive Worksheet (2010 Edition) =MEMO 2.04 36.0 12.24 30.0 MMEM� 18.0 6.12 40.0 13.60 MMEME 16.32 9.0 3.06 12.0 =MEMO 16.0 5.44 6.0 2.04 INMEMO, 5.44 16.0 5.44 16.0 MMEME 24.0 8.16 9.0 3.06 INMEMO 5.44 M©EMN MMEM� 318.0 MMEM: =MEMO =MEMO =MEMO MMEME =MNIMO MMEME MMEME MINNIME =MEMO EIMEMO =MEMO Sum of Area and UA Area Weighted U = UA/Area Glazing Area UA 6.0 2.04 36.0 12.24 30.0 10.20 18.0 6.12 40.0 13.60 48.0 16.32 9.0 3.06 12.0 4.08 16.0 5.44 6.0 2.04 16.0 5.44 16.0 5.44 16.0 5.44 24.0 8.16 9.0 3.06 160 5.44 318.0 108.12 0.34 WSUEEP10 -010 Copyright 2010 0vtrhead Glazing Plan Component Glazing Width Height ut t-eet Sum of Area and UA Area Weighted U = UA/Area Doube Glazed Garden Windows Section 602.7.2 Exception Plan Component Width Height ID Description Ct. Feet'"`" Feet In, Sum of Area Sum of Area X 3 (This total is automatically included in the glazing area total.) Glazing UA for Heating System Size Only = Area X 0.63 WSEC Prescriptive Worksheet (2010 Efton) Area UA WSUEEP10 -010 Copyright 2010 Simple Hosting System Size: Climate Zone 1 Protect lnrormstlon Soundbuilt Homes 2603 -C Indoor Design Temperature 70 Outdoor Design Temperature 21 Design Temperature Difference (AT) AT - Indoor - Outdoor Design Temp 49 Conditioned Floor Area 1 2598 Conditioned Volume 22,046 Glazing Copy Sum of UA from Glazing Schedule 122 Contact Informetron Attic U- Factor X Area = UA R-49 0.027 1338 36.1 R -38 Advanced 0 026 Single Rafter or Joist Vaulted Collings U- Factor X Area = UA R -38 Vented 0.027 180 4.3 Above Grade Wails U- Factor X Area = UA R -21 0.056 2577 144 3 Floors U- Factor X Area UA R -30 0.029 1650 47 9 Below Grade Walls U- Factor X Area = UA 2' Depth Walls 0.042 3.5' Depth Walls 0.041 7' Depth Walls 0.037 Slab Below Grade F- Factor X Len th UA 2' Depth 0.59 3.5' Depth 064 7' De th 0.57 Slab on Grade F- Factor X Len th UA R -10 2' perimeter 0.54 R -10 Full - Heated 0.55 Sum of UA 354 Envelope Heat Load 17359 Btu / Hour Sum of UA X AT Air Leakage Heat Load 11667 Btu / Hour ((Volume X 0.6) X AT) X 018)) Building Design Heat Load 29026 Btu / Hour Air Leakage + Envelope Heat Loss Building and Duct Heat Load 1.15 F-733-3-8-01 Btu / Hour If ducts are located in unconditioned space. Sum of Building Heat Loss X 1 15 If ducts are located in conditioned space. Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 150% 50070 Btu / Hour Building and Duct Heat Loss X 1.50 WSEC Prescriptive Worksheet (2010 Edition) WSUEEP10 -010 Copynght2010 U � M � � � M � � � �j � C N � � � � Q � -i� � CCf �-. � � � � � � Q U•�N � � � _ � � � � � � � vo >. � � .n c� c� � C� � � � � � � � c q � Z °' � � � � � � � � �'� ti � O a � � °' � � �3 � m � � °' p o � � � N � .,� � � �, � p> �, � � o �I.� � N � � -a � •N ^ � � � c r l �� � cv v � ti � � r� � � � �! •,� a� '� �.a �n U ti a�i � a� � ,� W J M U � cn r�� � J � � (� '''' � � •� � Z � Q � Q-� fB � p� Z Hrn � � o � U � "�I (n � M � � c O� z m X J � � Z v� c�a � � O —r c� M W � �n N � m �Q... N � � J � � � � � � c°v ZQ O U L J � � a Q U tn � � � � ~ cn Z H � N � +' � 'D O . . N � (B ��1(t.1fa ¢ � � � � � � � U <t u � � � � '� k7 �= Q (� � � N U 0 � W� � N N � � � V � J�` 1� � C C � � � � � ��f�� CD � � m � Q (n m .� � � � �� � �� Duct testing Ca'Icula#or (New Construction) _ House address or lot#: � M, �� _ Conditioned Floor Area: 24,� Duct tester Iocation: �y���� �oz,�(` _ Pressure tap location: � � Ring (if applicable): Open 1 2 3 - � �- At Rough ' otal Leakage) Test Method & Test2 Calculated Stand"aFdl• CFM�° Target Air Handler Present <_6 CFMZS per 100 sf of CFA .06 X CFA 5 CFM� Air Handier not Present - <_4 CFM�per 100 sf of CFA •04 X CFA<_ CFMu Post Co�structivn Test Method & TestZ Calculated Standardl CFM25 Target Air Handler Present(Total Leakage) � <_8 CFMu per 100 sf of CFA •�$X CFA 5 ' .CFM� = Air Handler Present(Leakage to Exterior) .06 X CFA<_ <_6 CFM er 100 sf of CFA CFM� zs P 1. Test resuits must comply with one of the Standards options. 2. Test CFM�must be equal to or less than the calculated target. � Air Leaka�e tes�ing Calcwlator (81o�ver Dvor Test) Standard Tested C�M50 Calculated Test Resutt � � (U•�� CFM50 X 0.055)= ��' FA X 144})=SLA 0.0003o s� t 3�-O , 3-� divided by J`���� SLq � SLA�2 C��l G! Glossary ' Raugh-in: After instailation of the comptete air distribution system but before installation of insulation and sheet rock. Allows for access to ail duct seams and connections for re-evaluation of seal integrity if standard is not met in intitial test_ Post Construction: At or near final inspection. The home must 6e complete enough to pressurize the home to 25 pa. Total Leakage:�Aggregation of the entire systems duct leakage in a duct test. ' leakage to Exterior: Aggregation of all duct system leaks to the exterior of the CFA in a duct test. CFA: Conditioned floor area � CFM�: Cubic feet per minute of air leakage at 25 pascals of pressure �FMso: Cubic feet per minute of air!ealcage at 50 pascals of pressure Pasca!(pa): Unit of pressure � - SLA: Specific leakage area - � �� __ _ � � � , �- - �. �-� ::' �� �� -� '���� � � �� � , p . �"' .,� � ��� � 7 i �' �� � I3uct Leakage Affidavit Permit#: .�� � � � Z/ `� + House address or lot number. G/ �, `T� �, �,.��'( City: K ����, Zip: � Cortd. Floor Area(ft�): �-��� Svurce(circle one): Plans Estimated Measured ►:. � �_, � ❑ Duct tightness testing is not required for this resi enc� per exceptions listed at the end of this document Air Handler in canditioned space?� �res no Air Handler present during test? yes 0 no Circle Test Method: Leakage to Outside otai Leakage Maximum duct leakage: Post Constrvcfion,total duct leakage: (floor area x.08)= CFM@25 Pa Post Construction, leakage to outdoors: (floor area x.06)= CFM@25 Pa Rough-�n,total duct leakage with alr handler instailed: (floor area x.06) _ /'�� CFM@25 Pa Rough-�n,total duct leakage with air handler not installed: (floor area x .04)= CFM@25 Pa Test Result: 7�k' CFM@25Pa .. � _ Ring (circle one if applicabie): Open 1 2 � 3 Duct Tester Location: � X�� � � Pressure Tap Location: �V � �v�� ��� 1 cErtify that these duct leakage rates are accurate and determined using standard duct testing protocal. Company Name:�.. ' `' ,� �'` p���•., Technician: �~,���,� i echnician Signature� . :�. �,�Date: V��`�� Phone Number.���,��� Washington State Energ�Cede referenc2: 503.�0.3 Sealing.All ducts,air handlers,filter boxes,and building cavities used as ducts shall be sealed.Joints and seams shall comply with Secfion M1601.3 of the Iniemational Residential Code or 603.9 of the lntemafional Mechanical Code. Duct tightness testing shail be ' ' conducted to verify that the ducts are sealed.A signed affida�iit documenting the test results shall be provided to the jurisdiction having authority by the testing agent When required by the building officiai,the test shail be conducted in the presence of department stafr. E:.captions: 1. Duct tightness test is not required if the air handler and all ducts are located within conditioned spaee. 2.Duct testing is not required if the fumace is a nondirect vent bjpe combustion appliance instalied in an uncondiiioned space. A maximum of six feei oi connected ductworlc in the unconditioned space is allowed.All additionai suppiy and retum ducts s` I `' '•`r�F�ccnditicnad pac°.Duc:s outside the conditicr,�d sp��a sha sa^! �+,,;� _,,.��±ic bj^�d::c±s.�lY^?�.^.d Q�'J:'f�1 l I 1 I 1 J I I ti� .A__ •i h n T, insulated on the e;derior with R-8 insulation for above grade ducts and P,-5�vater resistant insulation when within a slab or ""'� earth. � ' t