Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
20120276 Permit Pkg 09262012
City of Yelm Community Development Department Building Division Phone: (360) 458-8407 Fax: (360) 458-3144 Applicant: Name: SOUNDBUILT NW LLC Address: PO BOX 73790 PUYALLUP WA 98373 Property Information: Site Address: QQ5R -IFNliFN nR SF RO Permit No.: 20120276 Issue Date. 912 612 01 2 (Work must be completed within 180 days) Phone: 253- 848 -0820 Owner: SOUNDBUILT NW LLC Assessor Parcel No.: 78640106000 Subdivision: TAHOMA TERRA Lot: 60 Contractor Information: Name: SOUNDBUILT NW LLC Address: PO BOX 73790 PUYALLUP WA 98373 Phone: Contractor License No.: Expires: 0 /00 /0000 Project Information: Project: NEW RESIDENTIAL BUILDING Description of Work: LOT 60, PLAN 2068 Sq. Ft. per Floor: Heat Type (Electric, Gas, Other): GAS First 1142 Second 1137 Third Garage 430 Basement Fees: Item Contractor Fees NEW RESIDENTIAL BUILDING SOUNDBUILT NW LLC $13,346.16 MECHANICAL SOUND HEATING &AC $ 78.25 PLUMBING RAINER VIEW ROOTER $ 118.00 TOTAL FEES: $ 13,542.41 Applicant's Affidavit: I certify that I have read and examined the information contained within the application and know the same to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of Yelm regulations including those governing zoning and land subdivision, and in addition, all covenants, easements and restrictions of record. If applying as a contractor, I further certify that I am currently registered in the State of Washingtgq. Date 1 —1�� OFFICIAL USE ONLY # Sets of Prints: Final Inspection: Date. Firm By. City of Mi (36 ) 458 -8402 REC #: 00106305 9/26/2012 2:05 PM OPER: CO TERM: 001 REF #: 14465 TRAN: 33.0000 BUILDING PERMITS 20120245 23.85CR SOUNDBUILT NW LLC 9980 JENSEN DR SE 56 BLD -RES1 23.85CR TRAN; 33,0000 BUILDING PERMITS 20120280 14,660.08CR SOUNDBUILT NW LLC 9947 JENSEN OR SE 57 BLD -RES1 14,456,83CR MECH 78.25CR PL 125 -GOCR TRAN: 33,0000 BUILDING PERMITS 20120276 13,542.41CR SOUNDBUILT NW LLC 9956 JENSEN DR SE 60 BLD -RES1 13,346,16CR MECH 78.25CR PL 118.00CR TRAN: 33.0000 BUILDING PERMITS 20120275 13,804.82CR SOUNDBUILT NW LLC 9962 JENSEN DR SE 59 BLD -RES1 13,608.57CR MECH 78.25CR PL 118 -OOCR TRAN: 33.0000 BUILDING PERMITS 20120274 13,068.64CR SOUNDBUILT NW LLC 9968 JENSEN DR SE 58 BLD -RES1 12,892.89CR MECH 71,75CR PL 104.000R TENDERED: 55,099.80 CHECK APPLIED; 55,099.80- CHANGE; 0,00 CITY OF YELM &1k 0,�7& RE OOffIAL BUILDING PERMIT APPLICATION FORM Project Address :1995lo knri L)rsc Subdivaion�kWta tcrYCk- Lot*-44- Parcel#: r1 x 1 C 1 C (,,7C CC Plan #:.� i(n Zoning: New ConattudlOn ❑ Re -Model I Re -Roof 1 Addition Z Home Occupation Sign ❑ Plumbing ❑ Mechanical ❑ Mobile / Manufactured Home Placement ❑ Other Project DescriptioNScopeof Work 1&A1A (YJQ 5 ta 1n1k MJ&j hDfVW, Project Value: Building Area (sq. n) 1'r Floor_L 4 L 2"° Floor _a I Garage Deck Basement Carport Patio # Bedrooms # Bathrooms A- Heati . GAS/ THER or ELECTRIC (Circle One) Are there any environmentally sensitive areas located on the parcel? - N yes, a completed environmental checklist must accompany permit application. T] aff .. - dim: e t _ � .'IR,'j>��!TT�^R[�.�. • J -. ar LICENSE # ADDRESS r EMAIL lla,in en l Aj,4 rtarKalanSeDM CITY � STATE 4A .ZIP TELEPHONE &SA- Aft 1- .5 34 14 1 r TELEPHONE ADDR SS r EMAIL i r.Com CITY STATE ZIP FAX CONTRA TOR LICENSE # ad! ✓R4f2CF EXP DATE CITY LICENSE # TELEPHONE -276-M Sh ADDRESS EMAIL CITY STATE bi A ZIPyQxrs FAX CONTRA TORS LICENSE EXP DATUALCITY LICENSE # Copy of mitigation agreement with Yelm Community Schools, if applicable. I husby corft *Me* above IiAmmallon Is cornet"dud the eonsUmcdon on, and to oocupw" sod the use of the above described ptoprly will be In axardenoe whh the lore. rules and rsguleeons of the VMS of Wfthkgton and the clay of Yon. Q U� —�� ApPlk ant's n Daft Owner I Contiiator I Ownses Agent I Contractor's Agent (Please circle one.) All perils are non trsnsfsrebie and will expire If work authorhnd by such permit In not begun wtthin 160 days of Issuance, or H work Is suspended or abandoned for a period of 160 days ldd Yel+n Auenw Wad _ (ddp) Ifd-dddd Ye4n4 WA MS97 -- - -- --- - (dip) Idddlll PAZ rowwxtyelmwa.us nn j La LUI BY: -------------- - - - - -- -FA - -(L C L �1, rl TI JEN5EN [)RIVE 5E ;ell rn rTl Lh nn rd,? JEN5EN [)RIVE 5E ;ell rn rTl Lh Prescriptive Energy Code Compliance for Single Family and Duplex Housing: Zone 1 11t Information Contact Information Soundbuilt Homes 2068 -b -9 -2 This set of forms has been developed to assist permit applicants documenting compliance with the Washington State Energy Code, (2009 edition). This set is for structures built under the IRC and located in Climate Zone 1. The following forms provide much of the required documentation for plan review. The details noted here must also be shown on the drawings (WSEC 104.2). This form is not a substitute for the energy code itself. To obtain a copy of the energy code, go to the following web address. http: / /www.energy.wsu.edu /code ❑ Does not apply. (SEE INSTRUCTIONS) Using Prescriptive Option III All glazing and doors meet maximum U- factor. Alternate heating size method submitted. Q Option I or 11, Glazing to floor area limit (WSEC 602.7.2) Area weighted window, skylight or door U- factor (WSEC 602.7.2) As part of the heating system sizing calculation (IRC M1401.3 & WSEC 503.2.2) Radiant slab: ❑ R -10 foam insulation, continuous with thermal break (WSEC 502.1.4.9) Chapter 8 Options Total of 1 Credit Required Opt. Oot. Desnrintinn 1a Glazing 1 b Hi h Efficien2y HVAC Equipment 2 1c Hi h Efficiency HVAC Equipment 3 2 Hi h Efficien HVAC Distribution System 3a Efficient Option 10 Area GlaziHFactor 9 or nvelope 3 Vaulted Walt 12 ° Wall int Wall- ext° 5a Slab` 5b %of Floor 6 Ceiling Ceiling' Above Below Below Floor' on Verticaactor Grade Grad e Grade Grade R -09 or 13% 0.34 20 R -38 R -38 R 21 R -21 R -10 R -30 R -]0 Adv. Int.' TB 2' R-49 or II 25% 0.32 0.50 0.20 R -38 R -38 R-21 R -21 R -10 R -30 R -10 Adv. Int.7 TB 2 R-49 or II I Unlimited 0.30 0.50 0.20 R -38 R -38 R -21 R -21 R -10 R -30 R -10 Adv. Int.7 TB 2' See WSEC Inhia r, I hu / ennroe ❑ Does not apply. (SEE INSTRUCTIONS) Using Prescriptive Option III All glazing and doors meet maximum U- factor. Alternate heating size method submitted. Q Option I or 11, Glazing to floor area limit (WSEC 602.7.2) Area weighted window, skylight or door U- factor (WSEC 602.7.2) As part of the heating system sizing calculation (IRC M1401.3 & WSEC 503.2.2) Radiant slab: ❑ R -10 foam insulation, continuous with thermal break (WSEC 502.1.4.9) Chapter 8 Options Total of 1 Credit Required Opt. Oot. Desnrintinn 1a Hi h Efficient HVAC E ui ment 1 1 b Hi h Efficien2y HVAC Equipment 2 1c Hi h Efficiency HVAC Equipment 3 2 Hi h Efficien HVAC Distribution System 3a Efficient building Envelope 1 3b Efficient Bui din2 Envelope 2 3c nvelope 3 4a Air Leaka a Control and Efficient Ventilation 4b Additional Air Leakage Control and Efficient Ventilation 5a Efficient Water Heatin 5b Hi h Effieciency Water Heating 6 Small Dwelling Unit 7 Lar a Dwelling Unit 8 Renewable Electric Energy Total Cm im WSEC Prescnptive worksheet (2010 edition) Zone 1 '1200 kWh I� e,,�� & 1n� 11 1.0 El El El El 1.00 WSUEEP10-010 Copyright 2010 Glazing Schedule Pm& ct Information Contact Information Soundbuilt Homes 2068 -B -9 -2 Conditioned Floor Areal 22791 Sum of UA for Heating System Sizing F 92.3 Sum of All Glazing Areas From Belowl 265 Glazing to Floor Area Ratio 11 62% 602.7.2 Exception Ratio (not to exceed 1 %)F—D Exterior Doors Plan Component Door Percent Width Height Glazing Door Door ID Description Ref. U- factor Glazed nt Feet'no' Fast'"on Area Area HA Vertical Glazing (Windows, Glazed doors using Exception 602.6 #11) Plan Component Glazing Width Height ID Description Ref. U- factor Qt. Feet'"`" Feet'n"n ara a rr 0.200 1 2 8 6 '1 MEM©E 17.8 3.6 dining room 0.320 kitchen 0.320 =MEMO nook 0.320 nook ©EMO 0.320 bonus room M©OME 0.320 bedroom 4 0.320 bedroom 4 0.320 MMEME bedroom 3 0.320 bedroom 2 0.320 master bath MMEME 0.320 One Exempt Swinging Door < 24 Square Feet 0.200 1 3 6 s 20.0 4.0 Sum of Glazing Area, Door Area, and UA (do not include exempt door) Area Weighted U = UA/Area Sum of Area and UA for Heating system size only (include exempt door) 17.8 3.6 0.20 37.8 7.6 Vertical Glazing (Windows, Glazed doors using Exception 602.6 #11) Plan Component Glazing Width Height ID Description Ref. U- factor Qt. Feet'"`" Feet'n"n WSEC Prescriptive Worksheet (2010 Edition) ©©DINE living room rr 0.320 living room 0.320 entry MEM©E 0.320 dining room 0.320 kitchen 0.320 =MEMO nook 0.320 nook ©EMO 0.320 bonus room M©OME 0.320 bedroom 4 0.320 bedroom 4 0.320 MMEME bedroom 3 0.320 bedroom 2 0.320 master bath MMEME 0.320 master bedroom 0.320 =MEMO MMEME EMM E M �ME MMEME WSEC Prescriptive Worksheet (2010 Edition) ©©DINE rr M©EMN rr MEM©E IIIE©E©O =MEMO ©EMO M©OME =MEMO MMEME M©NMN MMEME �MEME =MEMO MMEME EMM E M �ME MMEME MMEM� MMMEE EMIIIIIEEM EIIIIIIIIIIIENME Sum of Area and UA Area Weighted U = UA/Area Glazing Area UA 264.81 84.75 0.32 WSUEEP10 -010 Copyright 2010 rr rr 264.81 84.75 0.32 WSUEEP10 -010 Copyright 2010 Overhead Glazing Plan Component 5- . . Glazing Width Height Qt. Feet '"d' Feet i" Sum of Area and UA Area Weighted U = UA/Area Doube Glazed Garden Windows Section 602.7.2 Exception Plan Component Width Height ID Description Qt. Feet Inch Feet Sum of Area Sum of Area X 3 (This total is automatically included in the glazing area total.) Glazing UA for Heating System Size Only = Area X 0.63 WSEC Prescriptive Worksheet (2010 Edition) Area UA WSUEEP10 -010 Copyright 2010 Simple Heating System Size: Climate Zone 1 Prop t Information ISoundbuilt Homes U- Factor 2068 -b -9 -2 Area R-49 0.027 Indoor Design Temperature 70 Outdoor Design Temperature 21 Design Temperature Difference (AT) 3.5' Depth AT = Indoor - Outdoor Design Temp 49 Conditioned Floor Area 2279 Conditioned Volume U- Factor 19,374 Glazing R -38 Vented Copy Sum of UA from Glazing Schedule 92 Attic U- Factor X Area R-49 0.027 Slab Below Grade f 417 R -38 Advanced 0.026 0.59 3.5' Depth 0.64 Single Rafter or Joist Vaulted Ceilings 0.57 Slab on Grade U- Factor X Area R -38 Vented 0.027 Above Grade Wails X U- Factor Area R -21 0.056 2417 Floors X U- Factor Area R -30 0.029 1387 Below Grade Walls X U- Factor Area 2' Depth Walls 0.042 3.5' Depth Walls 0.041 7' Depth Walls �0 Slab Below Grade F— Factor X 2' Depth 0.59 3.5' Depth 0.64 7' Depth 0.57 Slab on Grade F -Factor X R -10 2' perimeter 0.54 R -10 Full - Heated 0.55 Sum of UA Envelope Heat Load Sum of UA X AT Air Leakage Heat Load ((VolumeX 0.6)x AT) X.01ep Building Design Heat Load Air Leakage + Envelope Heat Loss Contact Information UA 38.3 UA UA 135.4 UA 306 15001 Btu / Hour 10253 Btu / Hour 25253 Btu / Hour Building and Duct Heat Load 1-1-51 F 29041 Btu / Hour If ducts are located in unconditioned space. Sum of Building Heat Loss X 1.15 If ducts are located in conditioned space: Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 150% 43562 Btu /Hour Building and Duct Heat Loss X 1.50 U � � � o � � � O N � C N � N (� _ � � � � � � � o � L � U•�N � � � � � � ai �j o >• �, � E o � u� � � � Z � o > q � � � � � � °' � � c� � rn � � � a � � a�i � � "� — �3 cmv c,,� � ° a� � O O `� �a ca "' 'v •,J ` � o) N � � p�j N � o ~ q � .� � �' � � � .� � -N � a�'—'' � n�i, '� '� � U � � � � � w -� � � � � J rn o � � a�`�i � ;� o z Q w .� � O � W � ti � � o � U T \ � U v Z m � � co � ._ �° � � O J N � � � ,N � CO � m } N � Q J � (�6 � O O � N N O Q U � � J U � � � Q C� cn � o -� � � �n ~ � Z � � p . . � N cjj "� � N � ,(a , � N N � J U "� U � � � � � � � U � g Q � � � �'" `� � Z Q � Y � � C "� C C � � f6 � "� �d m � � m � Q (n m � � � �c�> Z G2� � . Duct testing Calcula#or (Nevv ConstructionJ , � _ House address or lot#� ���� �,p���y4 ����,�. , (�� Conditioned F1oorArea: ��$ � Duct tester location: � � , _ Pressure tap location: � N-- Ring (if applicable): Open 1 2 3 � •^ �- At Rough-in (Total Leakage) � Test Method & TestZ � Caiculated Stand"aFdl CFM�• 5; Target � Air Handler Present �` 5 6 CFM�per 100 sf of CFA � .06 X CFA 5_GFM� � Air Handier not Present � S 4 CFM�per 100 sf of CFA . •�X CFA 5 CFM� . Post Construction � � . Tes�Method & �TestZ �alculated � Standardl CFMZS ' Target .. ` Alr Handler Present(TotaE Leakage) .08 X_�,_CFQ 5 ' CFMu 5 8 CFM�per 100 sf of CFA � � � . . Air Handler Present(Leakage to Exterior) .06 X CFA 5' CFM� • • <6 CFM�per 100 sF of CFA � 1. Test results must comply with one of the Standards options. 2. Test CFM�must be equal to or.less tttan the calculated target. • � � Air Leakage testing Calculator(B/ower poc�r Test) Standard � � . �M d Calculated Test Result _ 50 , � (l( 28�CFM50 X 0.055)=(��6�CFA X 144})=SLA 0.00030 SLA � 2�� � ' ' . 7Q•� divided by 2°I 7?�Z- gL,q . . SLA=�.�� Glossary � . ' . Rough-In: After installation of the complete air distri6ution system but before insta(lation of insulation and sheet rock. Allows for access to all duct seams and connections for re-evaluation of seal integrlty if standard ls not met in intitial test ��'� Post Construction: At or near final inspection. The home must be complete enough to pressurize the home to 25 pa. Total Leakage: Aggregation of the entire systems duct leakage in a duct test ' Leakag�to Exterior: Aggregation of all duct system leaks to the exterior of the CFA in a duct test. CFA: Conditioned floor a�ea . �FiVI�: Cubic feet per minute af air leakag2 at 25 pascals of pressure �FMso: Cubic�feet per minute of air leakage at 50 pascals of pressure Pasca!{pa): Unit uf pressure � � � — SLA: Specific leakage area � � ___ _,�__._ �..,_�.�._.._,_ . _ . � Duct Leakage Affidavit Permit#: °L C� 1 Z rJ2� (Q House address or lot number: �.�. �{'��di�l A- L.,.(Od City: ' �c L—W�. Zip: Cond. Floor Area (ft2): �►C'�tP� Source(circle one): Plans Estimated Measured i ❑ Duct tightness testing is not required for this res' ence per exceptions listed at the end of this document Air Handler in conditioned space?A �res no Air Handler present during test? yes � no Circ�e Test Method: Leakage to Outside otal Leaka e , Maximum duct/eakage: Post Constructlon,total duct leakage: (floor area x.OS)= CFM@25 Pa Post Construction, leakage to outdoors: (floor area x .06)= CFM@25 Pa . Rough-In,total duct leakage with air handier installed: (floor area x .06) _ �o?`i CFM@25 Pa _ Rough-In,total duct leakage with air handler not installed: (floor area x .04) = CFM@25 Pa Test Result: CFM@25Pa Ring (circle one if applicable): Open 1 2 3 Duct Tester Location:_Z�XZ-O 1` � Pressure Tap Location: ���1- CD,A�t. (3A•:N' " I certify that these duct leakage rates are accurate and determined using standard duct testing protocol. Company Name:�vu.#:� 1�� � 1���1�. Technician: ������ � Technician Signature� ' w� Date: ' �'/Z Phone Number:��.��� Washington State Energy Code reference: 503.10.3 Sealing.All ducts,air handlers,filter boxes,and building cavities used as ducts shall be sealed.Joints and seams shall comply •�� with Section M1601.3 of the Intemational Residentia/Code or 603.9 of the lntemational Mechanica!Code. Duct tightness testing shall be conducted to verify that the ducts are sealed.A signed affidavit documenting the test results shall be provided to the jurisdiction having authority by the testing agent.When required by the building o�cial,the test shall be conducted in the presence of department staff. Exceptions: 1.Duct tightness test is not required if the air handler and alI ducts are located within conditioned space. 2.Duct testing is not required if the furnace is a nondirect vent type combustion appliance installed in an unconditioned space. A maximum of six feet of connected ductwork in the unconditioned space is allowed.All additional supply and retum ducts , shall be withln the conditioned space.Ducts outside the conditioned spaca shall ba sQaled with a m2stic type duct�ealant and insulated on the exterior with R-8 insulation for above grade ducts and R-5 water resistant insulation when within a slab or earth.