Loading...
20120280 Permit Pkg 09262012City of Yelm Community Development Department Building Division Phone: (360)458.8407 Fax: (360) 458-3144 Applicant: Name: SOUNDBUILT NW LLC Address: PO BOX 73790 PUYALLUP WA 98373 Property Information: Site Address: 9947 JENSEN DR SE 57 Permit No.: 20120280 Issue Date: 9/2612012 (Work must be completed within 180 days) Phone: 253- 848 -0820 Owner: SOUNDBUILT NW LLC Assessor Parcel No.: 78640105700 Subdivision: TAHOMA TERRA Lot: 57 Contractor Information: Name: SOUNDBUILT NW LLC Address: PO BOX 73790 PUYALLUP WA 98373 Contractor License No.: Project Information: Project: NEW RESIDENTIAL BUILDING Description of Work: Sq. Ft. per floor: LOT 57. PLAN 2978 First 1367 Second 1602 Third Garage 438 Basement Fees: Item NEW RESIDENTIAL BUILDING MECHANICAL PLUMBING Expires: Phone: 0 /00/0000 Heat Type (Electric, Gas, Other): GAS Contractor Fees SOUNDBUILT NW LLC $14,456.83 SOUND HEATING & AC $ 78.25 RAINIER VIEW ROOTER $ 125.00 TOTAL FEES: $ 14,660,08 Applicant's Affidavit: I certify that I have read and examined the information contained within the application and know the same to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of Yelm regulations including those governing zoning and land subdivision, and in addition, all covenants, easements and restrictions of record. If applying as a contractor, I further certify that I am currently registered in the State of Washington. Q -� Signature —�fw— Date OFFICIAL USE ONLY # Sets of Prints: Final Inspection: Date: By: City of N1 (36 ) 458 -8402 REG #: 00106305 9/26/2012 2:05 PM OPER: CO TERM: 001 REF #: 14465 TRAN: 33,0000 BUILDING PERMITS 20120245 23.85CR SOUNDBUILT NW LLC 9980 JENSEN DR SE 56 BLD -RES1 23.85CR TRAN: 33.0000 BUILDING PERMITS 20120280 14,660,08CR SOUNDBUILT NW LLC 9947 JENSEN OR SE 57 BLD -RES1 14,456.83CR MECH 78.25CR PL 125.00CR TRAN: 33,0000 BUILDING PERMITS 20120276 13,542.41CR SOUNDBUILT NW LLC 9956 JENSEN DR SE 60 BLD -RES1 13,346.16CR MECH 78.25CR PL 118.000R TRAN: 33.0000 BUILDING PERMITS 20120275 13,804,82CR SOUNDBUILT NW LLC 9962 JENSEN OR SE 59 BLD -RES1 13,608.57CR MECH 78.25CR PL 118.000R TRAN: 33.0000 BUILDING PERMITS 20120274 13,068.64CR SOUNDBUILT NW LLC 9968 JENSEN DR SE 58 BLD -RES1 12,892,89CR MECH 71.75CR PL 104.000R TENDERED: 55,099.80 CHECK APPLIED: 55,099.80- CHANGE: 0.00 -rA - 5 rl CITY OF YELM RESIDENTIAL BUILDING PERMIT APPLICATION FORM 2vGZOZ� Project Address: q 917 4<h5n i Pr. 5,67 Parcel # 79e, :j o f t 7010 Subdivision:7-aitma f ro'n, Lot *.. 5 -7 Plan #: zY7� Zoning: New Construction ❑ Re -Model / Re -Roof / Addition C Home Occupation Sign ❑ Plumbing ❑ Mechanical ❑ Mobile / Manufactured Home Placement ❑ Other Project Description/Scope of Work 1"il.L (YW S( tt7tMr1 h ortc Project Value: n OJ Building Area (sq. ft) 1" Floor_L0 2nd Floor _I 'L'L Garage Deck Baaement �: Carport - Patio # Bedrooms # Bathrooms .0, Heating(S/OTHER or ELECTRIC (Circle One) Are there any environmentally sensitive areas located on the parcel? /�- N yss, a completed environmental checklist must accompany permit application. �'•'!}TI7�R! ow it LICENSE # ADDRESS 1,7n2 Mart SF !Suitew [04 EMAIL (i�in la.,dKavKOlanSl!owl CITY STATE.40W.ZIPjjjjQ TELEPHONE Irma f �TrTc a x :. 00-1-00 r TELEPHONES - - ADDRE�p A EMAIL i r.Ccm CITY (/ STATE ZIP FAX CONTRA TOR LICENSE # P DATE CITY LICENSE # TELEPHONE X0'475 -M56_ ADDRESS EMAIL CITY STATE ffAJ�AA��ZIP Cif 4- [S_FAX CONTRA TORS LICENSE #Sh"ddgg(aDB EXP DATEA&CITY LICENSE # Copy of mitigation agreement with Yelm Community Schools, if applicable 1 hereby cerft eret iM above hrfommuon is correct and that the conabuctlon on, and the occupancy and the use of tM above described prop" veal be In accordance with tM Wm, rules and regu"one of tM Maio of Washington and the city or YMm. Apl Ds11 Ow r Agent (Please circle one.) All work authorhod by such perrnit is not begun ww led or abandoned for a period of 180 days los t� Pelrn 0 t (aq) 45"1II FAX WWW. AUG ZU12 BY.................... LIJ O 0 (, - --- ----- ---- - -- - --- :,l U LLj LL, I— (/") O Q W Q >_ w ° c- < VV a N�SN�r _o�oom -- O ~ 2J0103dSNl 1 Q uj ).110 kS 03nOJddV W O Li < cc U N Y SV 0371VISNI 0 z LJ 0 J �rn 3S Ol 30N3J 1115 �J Q W W W � m Y N O X°W3w3 - Lli N d r N7VM �— n O lONtl211N3S N0I10021J.SN00 x-,c 1IO08 - --•t- _.JV -s u, LO 8L6Z NV�d U 0 ■3 5 ,ob ml� m m m — lf]S9 ,OZ L — 'NIW 'ltl0 ,Z 6tl3d a331011WHO 0 N II W J U (c, H Z � 0 O p a U Ld J 4 3oe z n D a O O 04 � b --u ON d W U Z uj �a 01 J r Q N Y N F- � LJ 0 J �rn W �K t Q W W W � m Y O X°W3w3 O � Q a 0- aJo W QU(/)mm - --•t- _.JV -s u, LO 8L6Z NV�d U 0 ■3 5 ,ob ml� m m m — lf]S9 ,OZ L — 'NIW 'ltl0 ,Z 6tl3d a331011WHO 0 N II W J U (c, H Z � 0 O p a U Ld J 4 3oe z n D a O O 04 � b --u ON d W U Z uj �a J r LJ 0 m N O 0 o0- z X t Q W W W � m Y X°W3w3 W z 0- aJo W QU(/)mm 3` Lt -£Z -8 Prescriptive Energy Code Compliance for Single Family and Duplex Housing: Zone 1 Project tnformation contact information 2978 This set of forms has been developed to assist permit applicants documenting compliance with the Washington State Energy Code, (2009 edition). This set is for structures built under the IRC and located in Climate Zone 1. The following forms provide much of the required documentation for plan review. The details noted here must also be shown on the drawings (WSEC 104.2). This form is not a substitute for the energy code itself. To obtain a copy of the energy code, go to the following web address, http: / /www.energy.wsu.edu /code See WSEC table 6 -1 for footnotes Glazing xneouie nnacnea to UOCLnlent ❑ Does not apply. (SEE INSTRUCTIONS) Using Prescriptive Option III. All glazing and doors meet maximum U- factor. Alternate heating size method submitted. E Option I or II, Glazing to floor area limit (WSEC 602.7.2) ❑ Area weighted window, skylight or door U- factor (WSEC 602.7.2) ❑ As part of the heating system sizing calculation (IRC M3401.3 & WSEC 503.2.2) Radiant slab: [] R -10 foam insulation, continuous with thermal break (WSEC 502.1.4.9) Chapter 9 Options Total of 1 Credit Required Ont Oot. Descriotion la Glazing 1b High Efficiency HVAC Equipment 2 1C High Efficiency HVAC Equipment 3 Wall" Wall- int' Wall- ext' Efficient Building Envelope 1 Slab6 Efficient Building Envelope 2 ,o Glazing U- Factor Doors Air Leakage Control and Efficient Ventilation Vaulted Additional Air Leakage Control and Efficient Ventilation 5a Efficient Water Heating s High Effieciency Water Heating Option Area 7 Large Dwelling Unit Ceiling' Renewable Electric Energy Above Below Below Floor on % of Floor Vertical Overhead' U- Factor Ceiling Grade Grade Grade Grade R -49 or R -21 R -21 R -10 U 7 13% 0.34 0.50 0.20 R -38 R -38 TB R -10 R -30 2, Adv. Int.' R -49 or R -21 R -21 R -10 Oil 25% 0.32 0.50 0.20 R -38 R -38 TB R -10 R -30 2, Adv. Int.' R -49 or R -21 R -21 R -10 0111 Unlimited 0.30 0.50 0.20 R -38 R -38 TB R -10 R -30 2 Adv. Int. See WSEC table 6 -1 for footnotes Glazing xneouie nnacnea to UOCLnlent ❑ Does not apply. (SEE INSTRUCTIONS) Using Prescriptive Option III. All glazing and doors meet maximum U- factor. Alternate heating size method submitted. E Option I or II, Glazing to floor area limit (WSEC 602.7.2) ❑ Area weighted window, skylight or door U- factor (WSEC 602.7.2) ❑ As part of the heating system sizing calculation (IRC M3401.3 & WSEC 503.2.2) Radiant slab: [] R -10 foam insulation, continuous with thermal break (WSEC 502.1.4.9) Chapter 9 Options Total of 1 Credit Required Ont Oot. Descriotion la High Efficiency HVAC Equipment 1 1b High Efficiency HVAC Equipment 2 1C High Efficiency HVAC Equipment 3 2 High Efficiency HVAC Distribution System 3a Efficient Building Envelope 1 3b Efficient Building Envelope 2 3c Super-Efficient Building Envelope 3 4a Air Leakage Control and Efficient Ventilation 4b Additional Air Leakage Control and Efficient Ventilation 5a Efficient Water Heating 51b High Effieciency Water Heating 6 Small Dwelling Unit 7 Large Dwelling Unit 8 Renewable Electric Energy Total Credits WSEC Prescriptive Worksheet (2010 edition) Zone 1 l- ---------- -- BY. '1200 kwh l WSUEEP10 -010 1.0 El El El El El El El 1.00 Copyright 2010 Grazing Schedule Protect Information Contact Inlormetion 2978 Conditioned Floor AreaF 2969 Sum of UA for Heating System Sizing F 125.2 Sum of All Glazing Areas From Below 328 Glazing to Floor Area Ratio 11.06% 602,7.2 Exception Ratio (not to exceed 1 %)E---� Exterior Doors Plan Component Door Percent Width Height Glazing Door Door N .... ,..',..t ;.... P.f I I-fortnr s=nort Ot Feet Inch Feet Inch Area Area UA V Ent Door 0.200 1 1 31 0.340 6 81 MMEME 20.0 4.0 Kitchen Fire Door (exempt door 0.340 0.540 Nook 1 21 MM 6 8 0.340 17.8 9.6 0.340 ME Playroom MMOME 0.340 Playroom 0.340 Bedroom 2 0.340 =MEMO Master Bath 0.340 Master Bedroom 0.340 Bedroom 4 EIMEIMO 0.340 One Exempt Swinging Door < 24 Square Feet 0.340 Walk in Closet 0.340 MMEME Bedroom 3 0.340 Sum of Glazing Area, Door Area, and UA (do not include exempt door) Area Weighted U = UA/Area Sum of Area and UA for Heating system size only (include exempt door) 37.8 13.6 1 0.36 1 37.8 13.6 Vertical Glazing (Windows, Glazed doors using Exception 602.6 #1) Plan Component Glazing Width Height In nPgr.rintion Ref. U- factor Qt. Feet Inch Feet Inch WSEC Prescriptive Worksheet (2010 Edition) MMEME jEntry 0.340 Den 0.340 Dintnq Room MMEME 0.340 Kitchen 0.340 Nook 0.340 MM Great Room 0.340 E Great Room 0.340 ME Playroom MMOME 0.340 Playroom 0.340 Bedroom 2 0.340 =MEMO Master Bath 0.340 Master Bedroom 0.340 Bedroom 4 EIMEIMO 0.340 Stair Landing 0.340 Walk in Closet 0.340 MMEME Bedroom 3 0.340 MMEME MMEME EIMEMO IMEE-O WSEC Prescriptive Worksheet (2010 Edition) MMEME MMEME MMEME MMEME MM E MM ME MMOME MMEME =MEMO =moms EIMEIMO MMEME MMEME MMEME MMEME EIMEMO IMEE-O IMEOME IMEM-N IMEMEE --E-E Sum of Area and UA Area Weighted U = UA/Area Glazing 328.31 111.63 0.34 WSUEEPIO -010 Copyright2010 Overhead Glazing Pian Component Glazing D Description Ref. U Width Height — InrA rccr Sum of Area and UA Area Weighted U = UA/Area Doube Glazed Garden Windows Section 602.7.2 Exception Plan Component Width Height ID Description Cit. Feet Inch Feet inch Sum of Area Sum of Area X 3 (This total is automatically included in the glazing area total.) Glazing UA for Heating System Size Only = Area X 0.63 WSEC Prescriptive Worksheet (2010 Edition) Area UA Area UA 0 d WSUEEP10 -010 Copyright 2010 Simple Heating System Size: Climate Zone 1 Prdject Information 2978 Indoor Design Temperature 70 Outdoor Design Temperature 19 Design Temperature Difference (AT) 0.037 AT = Indoor - Outdoor Design Temp 51 Conditioned Floor Area F- Factor X 2969 Conditioned Volume 3.5' Depth 25,719 Glazing 0.57 Copy Sum of UA from Glazing Schedule 125 Attic U- Factor X Area R -49 0.027 0.54 1679 R -38 Advanced 0.026 Single Rafter or Joist Vaulted Ceilings U- Factor X Area R -38 Vented 0.027 Above Grade Walls U- Factor X Area R -21 0.056 PEI Floors U- Factor X Area R -30 0.029 P1 Below Grade Walls U- Factor X Area 2' Depth Walls 0.042 3.5' Depth Walls 0.041 7' De th Walls 0.037 Slab Below Grade F- Factor X 2' Depth 0.59 3.5' Depth 0.64 7' De lh 0.57 Slab on Grade F- Factor X R -10 2' perimeter 0.54 R -10 Full - Heated 0.55 Sum of UA Envelope Heat Load Sum of UA X AT Air Leakage Heat Load ((Volume X 0.6) X AT) X .018)) Building Design Heat Load Air Leakage i Envelope Heat Loss Confect Information = UA 45.3 UA UA 147.8 UA 49.0 UA UA UA 367 18738 Btu / Hour 14166 Btu / Hour 32904 Btu / Hour Building and Duct Heat Load 1.15 37840 Btu /Hour If ducts are located in unconditioned space: Sum of Building Heat Loss X 1.15 If ducts are located in conditioned space: Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 150% F 56760 Btu / Hour Building and Duct Heat Loss X 1.50 WSEC Prescriptive Worksheet (2010 Edition) WSUEEPIO -010 Copyright 2010 U � M �j � i pp O � � N ln +� N N � � Q � � � � U L QO � � � �•V N � � -v � r- � � N +� U o >+ � � � � � � � � � � � � q � Z � � � � _ � � o a a �'� � � � � °' �1 � �3 0 °° V a� � � � � � � � O � N �� L n\ � � O � � � � � q � � �� � � .__ � � � -►� 'v � � N .� •� � M 3 � � U � � � � w J M V N � � � � J � � � � � '� � Z o Q � �� f0 O � W Jti � _ � �U � �i cn � ti � o � •� � � Z m X � ao � Z �n ca � ZpJ o ao W � �� cn � � m Q N I� � ,J � fa � � � � N Z � V � �, g Q U � � _ � � � N ~ �, z �- � . . � � � O � ° � � � � � J V � �U L � +R,� � a � � � 0 C � Q ZQ a � � U r -:� �' L �- � c`a N c� � � c c � � � �� �v �r`� m O O m � Q c� m ..y� s �� +y� - :i�t. � � �. . y�� . . . m . : . : . -�f�l " �Y�, �e .: '..- �Q '7 k. t: ��. ''�. g 7' � V l � I)uct i,sakage AffdaviT Permit#: ��%�C� �'e _ House address or lot number: � Ig `T� '"'"'�� � �7 � City: � „ ��p� Zip: - Cond. Fioor Area (ft2): ���1 Source (circle one); Plans Estimated Measured Duct ti htness testing is not required for this residence per exce{�tions listed at the end,of this document • ❑ 9 Air Handier in conditioned space? ❑ yes �no Air Handler present during test?�yes 0 no Circfe Test Method: Leakage to Outside Totai Leakage Nlaximum duct leakage: Post Construction,total duct leakage: (floor area x .08) = CFM@25 Pa Post Construction, leakage to outdoors: (floor area x.06)= CFM@25 Pa � Rough-Ir�,tatai duct leakage with air handler installed: (floor area x .06) = l � � CFM@25 Pa , �a�gh-9r�,total duct lea8cage with air handler not installed: (floor area x .04) _ �� CFM@25 Pa i'est Ras�l�: � CFM@25Pa 3 Ring (circle one if applicable): Open � 2 ' � Pressure Ta Location: ` � � Duct Tester Location: �4�Z� �/ p I c�r�i�y tf�at#l�es�duct leakage rates ar� accurate and de#ermi�led �s9ng standard duct t�sting protocoi. c�,` . . ` ���� � Company Name��°''':������ � ��� Technician: < � � � � Date:� �`��� Phone Number:���'���"� Technician Signature::�, Washington State Energy Code refersnca: 503.10.3 Sealing.All ducts,air handlers,filter boxes,and building cavities used as ducts shall be sealed.Joints an�i seams shali comply with Section M1601.3 of the/ntemational Residential Code or 603.9 of the Intemadona/Mechanical Code. Duct ti'ghtriess testing shali be conducted to verify that the ducts are sealed.A signed affidavit documenting the test results shall be provided to the f urisdiciion having authoriry by the test(ng agent.N/hen required by the building official,the test shall be conducted in the presence of department staff. Exceptions: 1.Duct tightness test is not required if the air handler and ail ducts are located within conditioned space. 2.Duct testing is not required if the furnaca is a nondirect vent type combustion appliance installed in an unconditioned space. A maximum of six feet of connected ductwork in the unconditioned space is allowed.Ali additional supply and ntum ducts shalf be wifhin the conditianed spac�.Ducts outside the conditioned spaca shall be sealed with a mastic rype duct sealant and • insulated on the exteriorwith R-8 insulation for above grade ducts and R-5 water resistant insulation when within a slab or earth. �, c� 2�f�, o z�C'i � . . � Duct #esting Colculator (Nerv ConstructionJ � . House address or lot#: �, , � . .S 7 Conditioned Floor Area: �c��c� � � Duct tester location: ��-�-- � 'k? ._ _ Pressure tap location: ,�o� Ring (if appiicable): Open 1 2 3 � �� �-- At Rough-in Total Leakage) � Test Method & Test� � Caiculated Stand"aFdl CFM�• :t Target � Air Handler Present ��' � . .06 X CFA 5 CFMu 5 6 CFM25 per 100 sf of CFA Air Handler not Present ,04 X CFA 5 . CFMu S 4 CFMu per 100 sf of CFA . � 'Post Construction � � � Tes� Method & �T�2 Calculated � Standardl CFM25 " Target .. ` Air Handler Present(TotaE Leakage). .08 X�_CF�4 5 ' CFM� 5 8 CFMu per 100 sf of CFA , � � • ,,. , "- Air Handler Present(leakage to Exterior) .06 X CFA 5' CFM� • 5 6 CFM�per 100 sf of CFA � 1. Test resuits must comply with one of the Standards options. 2. Test CFM�must be equal to or.less than the calculated target. ' � � Air Leakage testing Calc�latar(Blower poc�r Test) Standard � � . �M d Calculated Test Result _ 50 , . ((�G�ZC� CFM50 X 0.055)=(�CFA X 144))=SLA • 4 . 0.00030 SLA 7� � ' �� � � divided by ��7��v = �Lq . Su�=4:cx-�t GLossary � � _ � � Rough-In: After installation of the complete air distri6ution system but before installation of insulation and sheet rock. Allows for access to all duct seams and connections for re-evaluatian of seal integrity if standard is not met in intitial test ' 'k Post Construction: At or near final inspection. The home must be complete enough to Pressurize the home to 25 pa. Total Leakage:"Aggregation of the entire systems duct leakage in a duct test � Leakage to Exterior: Aggregation of all duct system leaks to the exterior of the CFA in a duct test. CFA: Conditioned floor a�ea , �F11r�: Cubic feet per minutz af air leakage at 25 pascals of pressure �FiVlso: Gubic�feet per minute of air leakage at 50 pastals of pressure Pasca!(pa): Unit of pressure ` -- SLA: Specific leakage area '