20120280 Permit Pkg 09262012City of Yelm
Community Development Department
Building Division
Phone: (360)458.8407
Fax: (360) 458-3144
Applicant:
Name: SOUNDBUILT NW LLC
Address: PO BOX 73790
PUYALLUP WA 98373
Property Information:
Site Address: 9947 JENSEN DR SE 57
Permit No.: 20120280
Issue Date: 9/2612012
(Work must be completed within 180 days)
Phone: 253- 848 -0820
Owner: SOUNDBUILT NW LLC
Assessor Parcel No.: 78640105700 Subdivision: TAHOMA TERRA Lot: 57
Contractor Information:
Name: SOUNDBUILT NW LLC
Address:
PO BOX 73790
PUYALLUP WA 98373
Contractor License No.:
Project Information:
Project: NEW RESIDENTIAL BUILDING
Description of Work:
Sq. Ft. per floor:
LOT 57. PLAN 2978
First 1367
Second 1602
Third
Garage 438
Basement
Fees:
Item
NEW RESIDENTIAL BUILDING
MECHANICAL
PLUMBING
Expires:
Phone:
0 /00/0000
Heat Type (Electric, Gas, Other): GAS
Contractor
Fees
SOUNDBUILT NW LLC
$14,456.83
SOUND HEATING & AC
$ 78.25
RAINIER VIEW ROOTER
$ 125.00
TOTAL FEES: $ 14,660,08
Applicant's Affidavit:
I certify that I have read and examined the information contained within the application and know the same
to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of
Yelm regulations including those governing zoning and land subdivision, and in addition, all covenants,
easements and restrictions of record. If applying as a contractor, I further certify that I am currently
registered in the State of Washington. Q -�
Signature —�fw— Date
OFFICIAL USE ONLY
# Sets of Prints:
Final Inspection:
Date:
By:
City of N1
(36 ) 458 -8402
REG #: 00106305 9/26/2012 2:05 PM
OPER: CO TERM: 001
REF #: 14465
TRAN: 33,0000 BUILDING PERMITS
20120245 23.85CR
SOUNDBUILT NW LLC
9980 JENSEN DR SE 56
BLD -RES1 23.85CR
TRAN: 33.0000 BUILDING PERMITS
20120280 14,660,08CR
SOUNDBUILT NW LLC
9947 JENSEN OR SE 57
BLD -RES1 14,456.83CR
MECH 78.25CR
PL 125.00CR
TRAN: 33,0000 BUILDING PERMITS
20120276 13,542.41CR
SOUNDBUILT NW LLC
9956 JENSEN DR SE 60
BLD -RES1 13,346.16CR
MECH 78.25CR
PL 118.000R
TRAN: 33.0000 BUILDING PERMITS
20120275 13,804,82CR
SOUNDBUILT NW LLC
9962 JENSEN OR SE 59
BLD -RES1 13,608.57CR
MECH 78.25CR
PL 118.000R
TRAN: 33.0000 BUILDING PERMITS
20120274 13,068.64CR
SOUNDBUILT NW LLC
9968 JENSEN DR SE 58
BLD -RES1 12,892,89CR
MECH 71.75CR
PL 104.000R
TENDERED: 55,099.80 CHECK
APPLIED: 55,099.80-
CHANGE: 0.00
-rA - 5 rl
CITY OF YELM
RESIDENTIAL BUILDING PERMIT APPLICATION FORM 2vGZOZ�
Project Address: q 917 4<h5n i Pr. 5,67 Parcel # 79e, :j o f t 7010
Subdivision:7-aitma f ro'n, Lot *.. 5 -7 Plan #: zY7� Zoning:
New Construction ❑ Re -Model / Re -Roof / Addition C Home Occupation Sign
❑ Plumbing ❑ Mechanical ❑ Mobile / Manufactured Home Placement ❑ Other
Project Description/Scope of Work 1"il.L (YW S( tt7tMr1 h ortc
Project Value: n OJ
Building Area (sq. ft) 1" Floor_L0 2nd Floor _I 'L'L Garage Deck
Baaement �: Carport - Patio
# Bedrooms #
Bathrooms .0, Heating(S/OTHER or ELECTRIC (Circle One)
Are there any environmentally sensitive areas located on the parcel? /�-
N yss, a completed environmental checklist must accompany permit application.
�'•'!}TI7�R!
ow it LICENSE #
ADDRESS 1,7n2 Mart SF !Suitew [04 EMAIL (i�in la.,dKavKOlanSl!owl
CITY STATE.40W.ZIPjjjjQ TELEPHONE
Irma
f �TrTc a x
:. 00-1-00
r TELEPHONES - -
ADDRE�p A EMAIL i r.Ccm
CITY (/ STATE ZIP FAX
CONTRA TOR LICENSE # P DATE CITY LICENSE #
TELEPHONE X0'475 -M56_
ADDRESS EMAIL
CITY STATE ffAJ�AA��ZIP Cif 4- [S_FAX
CONTRA TORS LICENSE #Sh"ddgg(aDB EXP DATEA&CITY LICENSE #
Copy of mitigation agreement with Yelm Community Schools, if applicable
1 hereby cerft eret iM above hrfommuon is correct and that the conabuctlon on, and the occupancy and the use of tM
above described prop" veal be In accordance with tM Wm, rules and regu"one of tM Maio of Washington and the
city or YMm.
Apl Ds11
Ow r Agent (Please circle one.)
All work authorhod by such perrnit is not begun
ww led or abandoned for a period of 180 days
los t�
Pelrn 0 t (aq) 45"1II FAX
WWW. AUG ZU12
BY....................
LIJ
O
0
(,
- --- ----- ---- - -- - --- :,l U
LLj LL,
I— (/") O Q
W
Q >_ w ° c- < VV a N�SN�r
_o�oom --
O ~ 2J0103dSNl
1
Q
uj
).110 kS 03nOJddV
W
O Li
<
cc
U
N
Y
SV 0371VISNI
0 z
LJ 0
J
�rn
3S Ol 30N3J 1115
�J
Q W W W
� m Y
N
O
X°W3w3
-
Lli
N
d
r
N7VM
�—
n
O
lONtl211N3S
N0I10021J.SN00
x-,c
1IO08
- --•t- _.JV -s
u,
LO
8L6Z
NV�d
U
0
■3
5
,ob
ml� m
m
m
— lf]S9 ,OZ L
— 'NIW 'ltl0 ,Z
6tl3d a331011WHO
0
N
II
W
J
U (c,
H
Z
� 0
O
p a U
Ld
J 4
3oe z
n D a
O
O
04 � b
--u ON
d
W
U
Z
uj
�a
01
J r
Q
N
Y
N
F-
�
LJ 0
J
�rn
W �K
t
Q W W W
� m Y
O
X°W3w3
O � Q
a
0-
aJo W
QU(/)mm
- --•t- _.JV -s
u,
LO
8L6Z
NV�d
U
0
■3
5
,ob
ml� m
m
m
— lf]S9 ,OZ L
— 'NIW 'ltl0 ,Z
6tl3d a331011WHO
0
N
II
W
J
U (c,
H
Z
� 0
O
p a U
Ld
J 4
3oe z
n D a
O
O
04 � b
--u ON
d
W
U
Z
uj
�a
J r
LJ 0
m N
O 0
o0- z
X
t
Q W W W
� m Y
X°W3w3
W z
0-
aJo W
QU(/)mm
3` Lt -£Z -8
Prescriptive Energy Code Compliance for Single Family and Duplex Housing: Zone 1
Project tnformation contact information
2978
This set of forms has been developed to assist permit applicants documenting compliance with the
Washington State Energy Code, (2009 edition). This set is for structures built under the IRC and located
in Climate Zone 1.
The following forms provide much of the required documentation for plan review. The details noted here
must also be shown on the drawings (WSEC 104.2).
This form is not a substitute for the energy code itself. To obtain a copy of the energy code,
go to the following web address, http: / /www.energy.wsu.edu /code
See WSEC table 6 -1 for footnotes
Glazing xneouie nnacnea to UOCLnlent
❑ Does not apply. (SEE INSTRUCTIONS) Using Prescriptive Option III. All glazing and
doors meet maximum U- factor. Alternate heating size method submitted.
E Option I or II, Glazing to floor area limit (WSEC 602.7.2)
❑ Area weighted window, skylight or door U- factor (WSEC 602.7.2)
❑ As part of the heating system sizing calculation (IRC M3401.3 & WSEC 503.2.2)
Radiant slab:
[] R -10 foam insulation, continuous with thermal break (WSEC 502.1.4.9)
Chapter 9 Options Total of 1 Credit Required
Ont Oot. Descriotion
la
Glazing
1b
High Efficiency HVAC Equipment 2
1C
High Efficiency HVAC Equipment 3
Wall"
Wall- int'
Wall- ext'
Efficient Building Envelope 1
Slab6
Efficient Building Envelope 2
,o
Glazing U- Factor
Doors
Air Leakage Control and Efficient Ventilation
Vaulted
Additional Air Leakage Control and Efficient Ventilation
5a
Efficient Water Heating
s
High Effieciency Water Heating
Option
Area
7
Large Dwelling Unit
Ceiling'
Renewable Electric Energy
Above
Below
Below
Floor
on
% of Floor
Vertical
Overhead'
U- Factor
Ceiling
Grade
Grade
Grade
Grade
R -49 or
R -21
R -21
R -10
U 7
13%
0.34
0.50
0.20
R -38
R -38
TB
R -10
R -30
2,
Adv.
Int.'
R -49 or
R -21
R -21
R -10
Oil
25%
0.32
0.50
0.20
R -38
R -38
TB
R -10
R -30
2,
Adv.
Int.'
R -49 or
R -21
R -21
R -10
0111
Unlimited
0.30
0.50
0.20
R -38
R -38
TB
R -10
R -30
2
Adv.
Int.
See WSEC table 6 -1 for footnotes
Glazing xneouie nnacnea to UOCLnlent
❑ Does not apply. (SEE INSTRUCTIONS) Using Prescriptive Option III. All glazing and
doors meet maximum U- factor. Alternate heating size method submitted.
E Option I or II, Glazing to floor area limit (WSEC 602.7.2)
❑ Area weighted window, skylight or door U- factor (WSEC 602.7.2)
❑ As part of the heating system sizing calculation (IRC M3401.3 & WSEC 503.2.2)
Radiant slab:
[] R -10 foam insulation, continuous with thermal break (WSEC 502.1.4.9)
Chapter 9 Options Total of 1 Credit Required
Ont Oot. Descriotion
la
High Efficiency HVAC Equipment 1
1b
High Efficiency HVAC Equipment 2
1C
High Efficiency HVAC Equipment 3
2
High Efficiency HVAC Distribution System
3a
Efficient Building Envelope 1
3b
Efficient Building Envelope 2
3c
Super-Efficient Building Envelope 3
4a
Air Leakage Control and Efficient Ventilation
4b
Additional Air Leakage Control and Efficient Ventilation
5a
Efficient Water Heating
51b
High Effieciency Water Heating
6
Small Dwelling Unit
7
Large Dwelling Unit
8
Renewable Electric Energy
Total Credits
WSEC Prescriptive Worksheet (2010 edition) Zone 1
l- ---------- --
BY.
'1200 kwh
l
WSUEEP10 -010
1.0
El
El
El
El
El
El
El
1.00
Copyright 2010
Grazing Schedule
Protect Information Contact Inlormetion
2978
Conditioned Floor AreaF 2969 Sum of UA for Heating System Sizing F 125.2
Sum of All Glazing Areas From Below 328
Glazing to Floor Area Ratio 11.06% 602,7.2 Exception Ratio (not to exceed 1 %)E---�
Exterior Doors
Plan Component Door Percent Width Height Glazing Door Door
N .... ,..',..t ;.... P.f I I-fortnr s=nort Ot Feet Inch Feet Inch Area Area UA
V
Ent Door
0.200
1
1 31
0.340
6
81
MMEME
20.0
4.0
Kitchen
Fire Door (exempt door
0.340
0.540
Nook
1
21
MM
6
8
0.340
17.8
9.6
0.340
ME
Playroom
MMOME
0.340
Playroom
0.340
Bedroom 2
0.340
=MEMO
Master Bath
0.340
Master Bedroom
0.340
Bedroom 4
EIMEIMO
0.340
One Exempt Swinging Door < 24 Square Feet
0.340
Walk in Closet
0.340
MMEME
Bedroom 3
0.340
Sum of Glazing Area, Door Area, and UA (do not include exempt door)
Area Weighted U = UA/Area
Sum of Area and UA for Heating system size only (include exempt door)
37.8
13.6
1 0.36
1
37.8
13.6
Vertical Glazing (Windows, Glazed doors using Exception 602.6 #1)
Plan Component Glazing Width Height
In nPgr.rintion Ref. U- factor Qt. Feet Inch Feet Inch
WSEC Prescriptive Worksheet (2010 Edition)
MMEME
jEntry
0.340
Den
0.340
Dintnq Room
MMEME
0.340
Kitchen
0.340
Nook
0.340
MM
Great Room
0.340
E
Great Room
0.340
ME
Playroom
MMOME
0.340
Playroom
0.340
Bedroom 2
0.340
=MEMO
Master Bath
0.340
Master Bedroom
0.340
Bedroom 4
EIMEIMO
0.340
Stair Landing
0.340
Walk in Closet
0.340
MMEME
Bedroom 3
0.340
MMEME
MMEME
EIMEMO
IMEE-O
WSEC Prescriptive Worksheet (2010 Edition)
MMEME
MMEME
MMEME
MMEME
MM
E
MM
ME
MMOME
MMEME
=MEMO
=moms
EIMEIMO
MMEME
MMEME
MMEME
MMEME
EIMEMO
IMEE-O
IMEOME
IMEM-N
IMEMEE
--E-E
Sum of Area and UA
Area Weighted U = UA/Area
Glazing
328.31 111.63
0.34
WSUEEPIO -010 Copyright2010
Overhead Glazing
Pian Component
Glazing
D
Description Ref. U
Width Height
— InrA
rccr
Sum of Area and UA
Area Weighted U = UA/Area
Doube Glazed Garden Windows Section 602.7.2 Exception
Plan Component Width Height
ID Description Cit. Feet Inch Feet inch
Sum of Area
Sum of Area X 3 (This total is automatically included in the glazing area total.)
Glazing UA for Heating System Size Only = Area X 0.63
WSEC Prescriptive Worksheet (2010 Edition)
Area UA
Area UA
0 d
WSUEEP10 -010 Copyright 2010
Simple Heating System Size: Climate Zone 1
Prdject Information
2978
Indoor Design Temperature
70
Outdoor Design Temperature
19
Design Temperature Difference (AT)
0.037
AT = Indoor - Outdoor Design Temp
51
Conditioned Floor Area
F- Factor X
2969
Conditioned Volume
3.5' Depth
25,719
Glazing
0.57
Copy Sum of UA from Glazing Schedule
125
Attic U- Factor
X Area
R -49 0.027
0.54
1679
R -38 Advanced 0.026
Single Rafter or Joist Vaulted Ceilings
U- Factor
X Area
R -38 Vented 0.027
Above Grade Walls U- Factor
X Area
R -21 0.056
PEI
Floors U- Factor
X Area
R -30 0.029
P1
Below Grade Walls U- Factor
X Area
2' Depth Walls
0.042
3.5' Depth Walls
0.041
7' De th Walls
0.037
Slab Below Grade
F- Factor X
2' Depth
0.59
3.5' Depth
0.64
7' De lh
0.57
Slab on Grade
F- Factor X
R -10 2' perimeter
0.54
R -10 Full - Heated
0.55
Sum of UA
Envelope Heat Load
Sum of UA X AT
Air Leakage Heat Load
((Volume X 0.6) X AT) X .018))
Building Design Heat Load
Air Leakage i Envelope Heat Loss
Confect Information
= UA
45.3
UA
UA
147.8
UA
49.0
UA
UA
UA
367
18738 Btu / Hour
14166 Btu / Hour
32904 Btu / Hour
Building and Duct Heat Load 1.15 37840 Btu /Hour
If ducts are located in unconditioned space: Sum of Building Heat Loss X 1.15
If ducts are located in conditioned space: Sum of Building Heat Loss X 1
Maximum Heat Equipment Output 150% F 56760 Btu / Hour
Building and Duct Heat Loss X 1.50
WSEC Prescriptive Worksheet (2010 Edition)
WSUEEPIO -010 Copyright 2010
U
�
M �j
� i
pp O �
� N ln +�
N N � �
Q �
�
� � U L QO
� � � �•V N
� � -v � r-
� � N +� U o >+
� � � � � � �
� � � � �
q � Z � � �
� _ �
� o a a �'�
� � � � °'
�1 � �3 0 °° V
a� �
� � � � � �
O �
N
�� L
n\ � � O �
� � � �
q � � ��
� � .__ �
� �
-►� 'v � � N
.� •� � M 3 � �
U � �
� � w J M V N �
� � � J � � � �
� '� � Z o Q � �� f0
O � W Jti � _ � �U
� �i cn � ti � o � •� � �
Z m X � ao � Z �n ca
� ZpJ o ao W � �� cn
� � m Q N I� � ,J � fa
� � � � N Z � V �
�, g Q U �
� _ �
� � N ~
�, z �- � . .
� � � O � ° �
� � � � J V � �U
L �
+R,� � a � � � 0
C
� Q ZQ a � � U
r -:� �' L �- � c`a N c� �
� c c � � � �� �v
�r`� m O O m � Q c� m
..y� s �� +y� - :i�t. � � �. . y�� . . .
m
. : .
: . -�f�l " �Y�, �e .: '..- �Q '7
k. t: ��. ''�.
g 7'
� V l �
I)uct i,sakage AffdaviT
Permit#: ��%�C� �'e _
House address or lot number: � Ig `T� '"'"'�� � �7 �
City: � „ ��p� Zip: -
Cond. Fioor Area (ft2): ���1 Source (circle one); Plans Estimated Measured
Duct ti htness testing is not required for this residence per exce{�tions listed at the end,of this document •
❑ 9
Air Handier in conditioned space? ❑ yes �no Air Handler present during test?�yes 0 no
Circfe Test Method: Leakage to Outside Totai Leakage
Nlaximum duct leakage:
Post Construction,total duct leakage: (floor area x .08) = CFM@25 Pa
Post Construction, leakage to outdoors: (floor area x.06)= CFM@25 Pa �
Rough-Ir�,tatai duct leakage with air handler installed: (floor area x .06) = l � � CFM@25 Pa
,
�a�gh-9r�,total duct lea8cage with air handler not installed: (floor area x .04) _
�� CFM@25 Pa
i'est Ras�l�: � CFM@25Pa
3
Ring (circle one if applicable): Open � 2 '
� Pressure Ta Location: ` � �
Duct Tester Location: �4�Z� �/ p
I c�r�i�y tf�at#l�es�duct leakage rates ar� accurate and de#ermi�led �s9ng standard duct t�sting protocoi.
c�,` . .
` ���� �
Company Name��°''':������ � ��� Technician: <
� � � � Date:� �`��� Phone Number:���'���"�
Technician Signature::�,
Washington State Energy Code refersnca:
503.10.3 Sealing.All ducts,air handlers,filter boxes,and building cavities used as ducts shall be sealed.Joints an�i seams shali comply
with Section M1601.3 of the/ntemational Residential Code or 603.9 of the Intemadona/Mechanical Code. Duct ti'ghtriess testing shali be
conducted to verify that the ducts are sealed.A signed affidavit documenting the test results shall be provided to the f urisdiciion having
authoriry by the test(ng agent.N/hen required by the building official,the test shall be conducted in the presence of department staff.
Exceptions: 1.Duct tightness test is not required if the air handler and ail ducts are located within conditioned space.
2.Duct testing is not required if the furnaca is a nondirect vent type combustion appliance installed in an unconditioned space.
A maximum of six feet of connected ductwork in the unconditioned space is allowed.Ali additional supply and ntum ducts
shalf be wifhin the conditianed spac�.Ducts outside the conditioned spaca shall be sealed with a mastic rype duct sealant and •
insulated on the exteriorwith R-8 insulation for above grade ducts and R-5 water resistant insulation when within a slab or
earth.
�,
c� 2�f�, o z�C'i � . .
� Duct #esting Colculator (Nerv ConstructionJ
� . House address or lot#: �, , � . .S 7
Conditioned Floor Area: �c��c� �
� Duct tester location: ��-�-- � 'k? ._
_ Pressure tap location: ,�o�
Ring (if appiicable): Open 1 2 3
� �� �-- At Rough-in Total Leakage)
� Test Method & Test� � Caiculated
Stand"aFdl CFM�• :t Target
� Air Handler Present ��' � .
.06 X CFA 5 CFMu
5 6 CFM25 per 100 sf of CFA
Air Handler not Present ,04 X CFA 5 . CFMu
S 4 CFMu per 100 sf of CFA .
� 'Post Construction � � �
Tes� Method & �T�2 Calculated
� Standardl CFM25 " Target .. `
Air Handler Present(TotaE Leakage). .08 X�_CF�4 5 ' CFM�
5 8 CFMu per 100 sf of CFA , � � •
,,. , "-
Air Handler Present(leakage to Exterior) .06 X CFA 5' CFM� •
5 6 CFM�per 100 sf of CFA �
1. Test resuits must comply with one of the Standards options.
2. Test CFM�must be equal to or.less than the calculated target. '
� � Air Leakage testing Calc�latar(Blower poc�r Test)
Standard � � . �M d Calculated Test Result _
50
, . ((�G�ZC� CFM50 X 0.055)=(�CFA X 144))=SLA
• 4 .
0.00030 SLA 7� � ' �� �
� divided by ��7��v = �Lq
. Su�=4:cx-�t
GLossary � � _ � �
Rough-In: After installation of the complete air distri6ution system but before installation of insulation and sheet rock. Allows for
access to all duct seams and connections for re-evaluatian of seal integrity if standard is not met in intitial test ' 'k
Post Construction: At or near final inspection. The home must be complete enough to Pressurize the home to 25 pa.
Total Leakage:"Aggregation of the entire systems duct leakage in a duct test �
Leakage to Exterior: Aggregation of all duct system leaks to the exterior of the CFA in a duct test.
CFA: Conditioned floor a�ea ,
�F11r�: Cubic feet per minutz af air leakage at 25 pascals of pressure
�FiVlso: Gubic�feet per minute of air leakage at 50 pastals of pressure
Pasca!(pa): Unit of pressure `
-- SLA: Specific leakage area '