Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
20120273 Permit Pkg 09212012
City of Yelm Community Development Department Building Division Phone: (360) 458 -8407 Fax: (360) 458-3144 Applicant: Name: FREESTONE Address: 6820 20TH ST E STE A FIFE WA 98424 Property Information Permit No.: 20120273 Issue Date: 912112012 (Work must be completed within 180 days) Phone: 253 - 896 -1300 Site Address: 15402 CHAD DR SE 22 Owner: FREESTONE INC Assessor Parcel No.: 41610002200 Subdivision: CHERRY MEADOWS Lot: 22 Contractor Information: Name: FREESTONE Phone: 253 -896 -1300 Address: RICK CARLILE 6820 20TH ST E STE A FIFE WA 98424 Contractor License No.: FREESI'969NZ Expires: 1/24/2011 Project Information: Project: NEW RESIDENTIAL BUILDING Description of Work: LOT 22, PLAN 2103A Sq. Ft. per floor: First 883 Heat Type (Electric, Gas, Other): Second 1220 Third Garage 448 Basement Fees: Item Contractor Fees NEW RESIDENTIAL BUILDING FREESTONE $16,120.94 MECHANICAL KLIEMANN BROS. $ 78.25 PLUMBING PELTRAM PLUMBING $ 118.00 TOTAL FEES: $ 16,317.19 Applicant's Affidavit: I certify that I have read and examined the information contained within the application and know the same to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of Yelm regulati Iuding those governing zoning and land subdivision, and in addition, all covenants, easements d re rictions of re If aqplying s a contractor, I further certify that I am urrenlly registered ii e t of Wa nes /' 1/,,II Signature /- �yVl.Iw Date Firm OFFICIAL USE ONLY # Sets of Prints: Final Inspection: Date: By: City of Me (36 ) 458 -8402 REC #: 00106129 9/21/2012 8:23 AM OPER: CO TERM: 001 REF #: 1466 TRAN: 33.0000 BUILDING PERMITS 20120273 16,317.19CR FREESTONE 15402 CHAD DR SE 22 BLD -RES1 16,120.94CR MECH 78.25CR PL 118.000R TENDERED: 16,317.19 CHECK APPLIED: 16,317.19- CHANGE: 0.00 YELM OWNITY 478 LS YELM WA 98597 Clerk: Croy Terminal: 189894 Receipt: Manual Receipt: NFREESTONE NFREESTONE FREESTONE, LLC F8IFE,20TH9ST E SUITE A 9/21/2012 8:13 AM Item _ Price 1 CPF MITIGATION 3015.00 MITIGATION 03 -021 / lot 22 1 15402 CHAD DR SE; YELM Subtotal: 3015;00 Tax: Total: 3015,00 Check 3015,00 1467 Change Due: 0.00 THANK YOU R NJ MW CITY OF YELM IIRESIDENTIAL BUILDING PERMIT APPLICATION FORM Project Address: V {f JI l.fUl � t,.) Se Parcel # 4I (' 100 024() 2 Subdivision: NEW Meldy of #:Oq� Plan #: 3 � Zoning: New Construction ❑ Re -Model / Re -Roof / Addition ❑ Home Occupation Sign ❑ Plumbing ❑ Mechanical �❑1 Mobile/ Manufactured Hom lacement ❑ Other Project Description /Scope of Work: t� e nu n Lk lA Q�[(- (t o Project Value: '2y0 3 Lao Building Area (sq. ft) 1" Floor 3 2n° Floor Garage Basement Carport a io # Bedrooms # Bathrooms -l2— HeatinQOOTHER or ELECTRIC (Circle One) Are there any environmentally sensitive areas located on the parcel? 1"J p— /f yes, a completed environmental checklist must accompany permit application. LICENSE# ADDRESS_ EMAIL O e—no r CpMocL CITY Bob hel STATE 11J ZIP aft TELEPHONE GENERAL CITY CITY LICENSE LICENSE R'S LICENSE Copy of mitigation agreement with Yelm EXP DATE -+—CITY LICENSE # �l ELEPHONE LaSZ f EMAIL )01 FAX :EXP DATE CITY LICENSE # -50 a&J! 5TELEPHONE a5b 5? EMAIL FAX ( 3lr� -219 -�! EXP DATEL CITY LICENSE # t /ar1�2OU{ Community Schools, if applicable I here rUfy that the above Information is correct and that the construction on, and the occupancy and the use of the ab a des ribad property will be In accordance with the laws, rules and regulations of the State of Washington and the Cl of Ve Applican Slgnatur Date l Owner / Contractor / (Owner's Agent / ontractor's Agent (Please circle one.) All permits are non - transferable and will expire If work authorized by such permit Is not begun within 180 days of Issuance, or if work is suspended or abandoned for a period of 180 days .- - C" �' I Ii I I Z...JC' \' LCZ3a U 105 Yelm Avenue West (360) 8 -3836 Yelm, WA 88587 (360) 458 -3144 FAX wwro.ct.yelm.mo. ur BY. - L.UNU vvHL^ 52.00 ry PLANTER 6' N,' CURB IGUTTER Z ----- - - - - -- rly C CHAD DRIVE 5E NO 5' EAVE CONNECT 4" PVC ROOF ENCROACHMENT THIS LOT DRAINS TO DRYWELL LOT 22 - CHERRY MEADOWS PARCEL #: 416100 022 00 ' ° " ^er Freestore Gherru Meadows LLO 52.00 LO 6520 20th 5t. E 5vite A L20'T L22 L 5,996 Sq. Ft. 15402 CHAD DRIVE SE 255- 816 -1500 SCALE:1 " =20' �p M I �I ! .1 cY Iy_DR_YWELL N ro 1 OI I REAR SETBACK ! — -_ � � I 20 12 ROOF - COV PATIO I, IIDRAINS I 2103 A STD DIAG 55.17' T 3 w (T w I 2 CAR G0. GARAGE COv. i PORCH Nf 22' L - - -. 0 _..._— i CO NC. `� DRIVE F ) NI T SEPARATION SEPARATION OR SLEEVE — UTILITYESMT WATER LINE �1 L.UNU vvHL^ 52.00 ry PLANTER 6' N,' CURB IGUTTER Z ----- - - - - -- rly C CHAD DRIVE 5E NO 5' EAVE CONNECT 4" PVC ROOF ENCROACHMENT THIS LOT DRAINS TO DRYWELL LOT 22 - CHERRY MEADOWS PARCEL #: 416100 022 00 ' ° " ^er Freestore Gherru Meadows LLO Lot 51ze Project Address 6520 20th 5t. E 5vite A Fife, WA 18424 5,996 Sq. Ft. 15402 CHAD DRIVE SE 255- 816 -1500 Prescriptive Energy Code Compliance for Single Family and Duplex Housing: Zone 1 Project Information Contact Information Freestone Plait. a, 312134 = • i., Freestonem atlas 6820;20 ti,..tl`sie A - Yelm' �, �Ife1MA 24 2S3 '8964 30Q! i, ;m r.. Ripk srlllo' This set of forms has been developed to assist permit applicants documenting compliance with the Washington State Energy Code, (2009 edition). This set is for structures built under the IRC and located in Climate Zone 1. The following forms provide much of the required documentation for plan review. The details noted here must also be shown on the drawings (WSEC 104.2). This form is not a substitute for the energy code itself. To obtain a copy of the energy code, go to the following web address. http: / /www.energy.wsu.edu /code See WSEC table 6-1 for footnotes - Glazing Schedule Attached to C ❑ Does not apply. (SEE INSTRUCTIONS) Using Prescriptive Option III. All glazing and doors meet maximum U- factor. Alternate heating size method submitted. 0 Option I or II, Glazing to floor area limit (WSEC 602.7.2) ❑ Area weighted window, skylight or door U- factor (WSEC 602.7.2) ❑ As part of the heating system sizing calculation (IRC M1401.3 & WSEC 503.2.2) Radiant slab: ❑ R -10 foam insulation, continuous with thermal break (WSEC 502.1.4.9) Chapter 9 Options Total of 1 Credit Required Opt. Opt. Description 1a Glazing mo Glazing U-Factor Door 1c Vaulted m2 Wall a Wall- int a Wall- ext Efficient Building Envelope 1 c Slab Option Area Super-Efficient Building Envelope 3 4a Ceiling2 3 Above Below Below Floors on Vertical Overheadmm 7 %of Floor U- Factor Renewable Electric Energy Ceiling Grade Grade Grade Grade R -49 or QQ I 13% 0.34 0.50 0.20 R -38 R -38 R -21 R -21 R -10 R -30 R -10 Adv. Int. 1B 2 R -49 or Q II 25% 0.32 0.50 0.20 R -38 R -38 R-2? R -10 R -30 R2 Adv. Int. TB TB 2' R -49 or Q III Unlimited 0.30 0.50 0.20 R -38 R -38 R -21 R -21 R -10 R -30 R -10 Adv. Int.7 TB 2' See WSEC table 6-1 for footnotes - Glazing Schedule Attached to C ❑ Does not apply. (SEE INSTRUCTIONS) Using Prescriptive Option III. All glazing and doors meet maximum U- factor. Alternate heating size method submitted. 0 Option I or II, Glazing to floor area limit (WSEC 602.7.2) ❑ Area weighted window, skylight or door U- factor (WSEC 602.7.2) ❑ As part of the heating system sizing calculation (IRC M1401.3 & WSEC 503.2.2) Radiant slab: ❑ R -10 foam insulation, continuous with thermal break (WSEC 502.1.4.9) Chapter 9 Options Total of 1 Credit Required Opt. Opt. Description 1a High Efficie cy HVAC Equipment 1 1b High Efficiency HVAC Equipment 2 1c High Efficiency HVAC Equipment 3 2 High Efficiency HVAC Distribution System 3a Efficient Building Envelope 1 3b Efficient Building Envelope 2 3c Super-Efficient Building Envelope 3 4a Air Leakage Control and Efficient Ventilation 4b Additional Air Leakage Control and Efficient Ventilation 5a Efficient Water Heating 51b High Effieciency Water Heating 6 Small Dwelling Unit 7 Large Dwelling Unit 8 Renewable Electric Energy Total Credits "1200 kwh 1.0 0 1.00 WSEC Prescriptive Worksheet (2010 edition) Zone 1 WSUEEP10 -010 Copyright 2010 Glazing Schedule Project Information Contact Intormation Freestone Plan 2103/2134 Freestone Companies 6820 20th St E Suite A Yelm Fife WA 98424 253 - 896 -1300 Rick Carlile 253 - 381 -6080 Conditioned Floor Area 2134 Sum of UA for Heating System Sizing 95.8 Sum of All Glazing Areas From Below 275 Glazing to Floor Area Ratio 12.91 % 602.7.2 Exception Ratio (not to exceed 1 %) Exterior Doors Plan Component Door Percent Width Height Glazing Door Door ID Description Ref U- factor Glazed Ot Feet 1oc1i Feet Inch Area Area UA Ent Fiberglass Insulated IECC 0.160 Ent 1 3 0.320 61 s NFRC 20.0 3.2 2 Glz Vinyl Low E PW NFRC 0.320 Din 2 Glz Vinyl Low E Super Spacer SGD NFRC 0.330 Kit 2 Glz Vinyl Low E NFRC 0.340 Up 2 Glz Vin I Low E NFRC 0.340 MBR 12 Glz Vinyl Low E NFRC 0.340 MBA 2 Glz Vinyl Low E NFRC 0.340 MBR 2 Glz Vinyl Low E PW NFRC 0.320 MMEMN ©©E©O MMEMN Gar One Exempt Swinging Door < 24 Square Feet 1 2 e 6 a 17.8 Sum of Glazing Area, Door Area, and UA (do not include exempt door) Area Weighted U = UA/Area Sum of Area and UA for Heating system size only (include exempt door) 1 1 20.01 3.2 1 0.16 1 1 37.81 3.2 Vertical Glazing (Windows, Glazed doors using Exception 602.6 #1) Plan Component Glazing Width Height ID Description Ref. U- factor Qt. Feet Inc" Feet Inch Ent 2 Glz Vinyl Low E PW NFRC 0.320 Ent 2 GIz Vinyl Low E PW NFRC 0.320 D &G 2 Glz Vinyl Low E NFRC 0.340 Gr 2 Glz Vinyl Low E PW NFRC 0.320 Din 2 Glz Vinyl Low E Super Spacer SGD NFRC 0.330 Kit 2 Glz Vinyl Low E NFRC 0.340 Up 2 Glz Vin I Low E NFRC 0.340 MBR 12 Glz Vinyl Low E NFRC 0.340 MBA 2 Glz Vinyl Low E NFRC 0.340 MBR 2 Glz Vinyl Low E PW NFRC 0.320 MMEMN ©©E©O MMEMN NNEEMO MENINEEN NOISOME MMEME MMEMN WSEC Prescriptive Worksheet (2010 Edition) ONM©ME MENI©E ©ME©O, ©©E©E MMOME NEM ME, MIN ME MMEME MMEMN ©©E©O MMEMN NNEEMO MENINEEN NOISOME MMEME MMEMN MMEME MMEME MMEME MMEMN Sum of Area and UA Area Weighted U = UA/Area Glazing Area UA 275.41 92.57 0.34 WSUEEP10 -010 Copyright 2010 Overhead Glazing Plan Component Glazing ID Description Ref. U Width Height Qt. Feet Inch Feet Inch Sum of Area and UA Area Weighted U = UA/Area Doube Glazed Garden Windows Section 602.7.2 Exception Plan Component Width Height ID Description Qt. Feet Inc' Feet Inch Sum of Area Sum of Area X 3 (This total is automatically included in the glazing area total.) Glazing UA for Heating System Size Only = Area X 0.63 WSEC Prescriptive Worksheet (2010 Edition) Area UA WSUEEP10 -010 Copyright 2010 Simple Heating System Size: Climate Zone 1 Project Information Freestone Plan 2103/2134 U- Factor Yelm R -49 0.027 Indoor Design Temperature 70 Outdoor Design Temperature 17 Design Temperature Difference (AT) AT = Indoor - Outdoor Design Temp 53 Conditioned Floor Area U- Factor 2134 Conditioned Volume 0.027 17 707 Glazing Above Grade Walls Copy Sum of UA from Glazing Schedule 96 Attic U- Factor X Area R -49 0.027 1220 R -38 Advanced 0.026 Single Rafter or Joist Vaulted Ceilings U- Factor X Area R -38 Vented 0.027 Above Grade Walls X Area U- Factor R -21 0.056 F 2069 Floors X Area U- Factor R -30 0.029 F 1224 Below Grade Walls X Area U- Factor 2' Depth Walls 0.042 3.5' Depth Walls 0.041 7' Depth Walls 0.037 N 1 Slab Below Grade X Len th F- Factor 2' Depth 0.59 3.5' Depth 0.64 7' Depth 0.57 Slab on Grade X Lel th F- Factor R -10 2' perimeter 0.54 R -10 Full - Heated 0.55 Sum of UA Envelope Heat Load Sum of UA X AT Air Leakage Heat Load ((Volume X 0.6) X AT) X .018)) Building Design Heat Load Air Leakage + Envelope Heat Loss Contact Information Freestone Companies 6820 20th St E Suite A Fife WA 98424 253 - 896 -1300 Rick Carlile 253 -381 -6080 = UA 32.9 = UA = UA 115.9 UA 35.5 UA = UA UA 280 14844 Btu / Hour 10135 Btu / Hour 24979 Btu / Hour Building and Duct Heat Load 1.15 28726 Btu / Hour If ducts are located in unconditioned space. Sum of Building Heat Loss X 1.15 If ducts are located in conditioned space: Sum of Building Heal Loss X 1 Maximum Heat Equipment Output Building and Duct Heat Loss X 1.50 150% 1 43089 Btu / Hour WSEC Prescriptive Worksheet (2010 Edition) WSUEEP10 -010 Copyright 2010 U M � � � Q O � c7 N � O � ln C N N � � � � ,� � � � r� � � � � O � C �. � � � U•V N ,� � � � c- $� � � � U O >+ � � V � � C� E o � N � ^N � Z c o > '�I O c � V v cv v� � � �v � � a � •� a�i � � � � � cmv � c, ° � � o � �' O � •`'� _ � � � ,� � ") o � a � c oti � � � q � � � � � �_ � � � "� •� Q � � � �a � N �' � W � � t � � � cn � 0 c6 �� .,J � LLJ � W 'fl-� � � � � � � � � � t O p W � oo � o � U r , � U �J = 0 = M � .0 0 � � � a � N Q � o � � N M � � � � p N O � U � � LL c0 LL N Z U Q � L g � " � a� a Q C� cn � N '� � N � ~ � Z � � . . �n �, � o a� � � � � N N � J U � �U �.� a � � -p N Q 0 `� � i Q (6 "� � � � � Z Q l� � V � � � Y � tJ� '�C- N N � (0 t� •V ,�-a C C — � � N �r� m O O m � Q c� m Jan. 29, 2013 2; 18PM Kl i emann Bros HVAC No. 9898 P. 1 . � r �� � ;.$ ^. ��� _ � �:�s % ��,. J l)uct Lea�age Affi�avlt � Permlt�: ��Z�-'2�-� _ House address or lot number:t��GZ C���f�� ____ Cify: _ �Ip: -- i���—T,. Cond.FloorArea(ft�):��f�� Source(circle one): Platls Estim�ted Measured ❑buct tighiness testing is not required for thfs resldence per exceptlons ilsted at the end o'f thls documeht Alr Handler In condlf(oned space?❑yes�io Air Wandler presettt during test?�yes d no Circle Test Method: l.eakage to Oufslde Tofal Leaka e Maximum ducf/eakage: Post Construction,to#a[ducf leakage:(ffoor area x_OB)__ CFM t�D25 Pa Post Construcftony Ieakage fo outdoors: (floor area x.06)_ ___C�M@25 Pa Rough�In,total duct leakage w[th alr handler Instarled:(floar area x.06) �1_a�.CFM aQ25 Pa Rough-In,tofa[duct leakage with air handler not insta[leci: (floor area x,04)__ CFM@26 Pa Test Result:��CFM@25Pa Ring tc�l�cle one If applicable}: Open 1 , 2 3 Duct Tes#er Location:�d`�1,J� __ Pressure Tap Lo�atipn:�?����u r�� T�-' �i4— � / 1 cert[fy that these duat leakage rates are accurate and deterrnined using stand rd duct testing protoco[. v�' Compa�iy Nams:��,��yl'1���,�_ _7echnician��� - �_��- Techhlcfan Signature:„� ' _ ,� ,.Dafe:_//��Z phone Number: ✓✓7 �?� Washfngton 5fate�nergy code reference: . 503.9U.3 Sealing.All ducls,afr hand�ers,filler boXes,and bu[Iding caViQes used as ducts shall be sealed_.lolnls and seams shall 4omply vrilh Section M1601.3 of fhe Intemallonal Resldentlal Code or 603.9 of the IntematlonalMechan/cal Code. duct Ughlness fesl�ng shall ba conducted fo ved(y lhaf lha ducts are sealed.A slgned ettld�viC docurnanting Iha test resulte ahall be protided to the jurisd[ctlon having euthorlly hy lhe teeling sgent.When requl�ed by Ihe building oflicial,lhe test ahall be conducted in lhe presence oF departmant slaff, �xr,apllone: 1.Puct(ightnees leaC is not required if lhe air handfer and all ducis are focafed within condiilonad space. 2.Duct testing is not required if ihe fumaca Is a nondlrect vent Lypa combusllon appllance]nslelled(n en uncondii4otied 8paC8. A maxlmum of sfx Feel of connecied ductwork In ihe uncondllloned spsee la elfoWed,All addillonal supply and relum ducfs shail be vufthln Ihe conditloned space_Ducfs out4lde tha cnttdlllvned spacs shall be seated with a mastic fype duct sealant and lnaafated on lhe exterfor with R-8 Insulation for abova grade ducls and RS vraler resistant lnsulallon whan wllhln a slab or earih.