Loading...
20120281 Permit Pkg 09212012City of Yelm Community Development Department Building Division Phone: (360) 458-8407 Fax: (360) 458-3144 Permit No.: 20120281 Issue Date: 912112012 (Work must be completed within 180 days) Applicant: Name: R & P HOMES LLC Phone: 253 - 405 -1864 Address: 11012 CANYON RD E, STE 8 PUYALLUP WA 98373 Property Information: Site Address: 10112 TERRA GLENN ST SE 39 Owner: R & P HOMES Assessor Parcel No.: 81780003900 Subdivision: VINTAGE GREENS Lot: 39 Contractor Information: Name: R & P HOMES LLC Address: 11012 CANYON RD E, STE 8 PUYALLUP WA 98373 Contractor License No.: Project Information: Project: NEW RESIDENTIAL BUILDING Phone: Expires: 0 /00/0000 Description of Work: LOT 39, PLAN 5872 1500 GALLON TANK Sq. Ft. per Floor: First 1053 Heat Type (Electric, Gas, Other): Second 1231 Third Garage 415 Basement Fees: Item Contractor NEW RESIDENTIAL BUILDING R & P HOMES LLC MECHANICAL KLIEMANN BROS. PLUMBING RICK THE PLUMBER TOTAL FEES: GAS Applicant's Affidavit: I certify that I have read and examined the information contained within the application and know the same to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of Yelm regulations including those governing zoning and land subdivision, and in addition, all covenants, easements and restrictions of record. If app) ing as a contractor, I further certify that I am current) registered in the StatgefVshington. Firm Fees $16,643.05 $ 78.25 $ 139.00 $ 16,860.30 OFFICIAL USE ONLY # Sets of Prints. Final Inspection: Date. By City of Velr (36 ) 456 -6402 REC #: 00106158 9/21/2012 3:50 PM OPER: CO TERM: 001 REF #: 3443 TRAN: 33.0000 BUILDING 3OCRITS 20120281 R & P HOMES LLC 10112 TERRA GLENN T SE 3 BLD -RES1 78,25CR MECH 139.000R PL TENDERED: 16,860.30 CHECK APPLIED: 16,860.30 - CHANGE: 0.00 V YELM COMMUNITY SCHOOLS 20/2-1 5 0 8 7 1 LOCAL RECEIPT DATE Received from __ �c%� •�--`+ '� S FOR M� ^� DOLLARS QD- YELM COMMUMTV SCHOOLS d `U2R) CITY OF YELM RESIDENTIAL BUILDING PERMIT APPLICATION FORIA O r /„n �'i£ parcel #1__ o 000.]_7�+�! Project Address: / //3 T //t '70 { Lott #.� Zoning: Subdivision: }}cc,��,,�� X New ConstntctioA—C - {¢Q l e-Mcdal I Re•Roof I Addition Home Occupation Sign �( Plumbing yP' Mechanical Mobile I Manufactured Home Placement Olhx Project Description Scope of Work: r Project Value I Building Area (sq. R) t" Floor( 2n° Floor �23f Garage 41ff /$ou yal A4K Basement Carport Patio # Bedmomsrl� .CBS # Bathroomv� -�� Heati HER or EL IC (Circle One) Are there any environmentally sensitive areas located on the parcel? If yes, a completed environmental checklist must accompany permit application. RDI11 =92 1,7 71 tai It GENERAL CONTRACTOR TELEPHONE_ - ADDRESS S< YAW_ EMAIL CITY STATE ZIP FAX CONTRACTOR'S LICENSE # EXP DATE_CITY LIGENSE # PLUMBING CONTRACTOR TELEPHONE-7—c - - ADDRESS Z!' o n EMAIL CITY STATE ZIP FAX CONTRACTOR'S LICENSE # EXP DATE CITY LICENSE # Copy or mitigation agreement with Yelm Community Schools, if applicable. I hereby candy that the above bdorrnaeon Is correct and that the construction on, and the occupancy and the use of the above described property will be In accordance with the laws, rules and regulations of the Skate of Washington and the clivred Valin I Dare ;ontractoor's Agent (Please circle one.) Y ✓✓ ! /// ill expire if work authorized by such permit is not begun is suspended or abandoned for a period of 180 days (sea) 101111ass (860) !6114144 1= AUK ; 2012 I , " x4l* -�p 2--O/Z C,)-Z�/ APPROVED �.e 1 5,5 91 j a - 3-)a A:5p-* -,at of '41C MO fjlqll JI) APPROVED 1=71 ; rc *. r roc M - �Z-WZIL Simple Heating System Size: Climate Zone 1 Project Information U- Factor Plan #5872 2278sf R -49 0.027 R -38 Advanced Indoor Design Temperature 70 Outdoor Design Temperature 19 Design Temperature Difference (AT) AT = Indoor - Outdoor Design Temp 51 Conditioned Floor Area R -38 Vented 2278 Conditioned Volume 19325 Glazing X Area Copy Sum of UA from Glazing Schedule F 103 Attic U- Factor X Area R -49 0.027 R -38 Advanced 0.026 1231 Single Rafter or Joist Vaulted Ceilings U- Factor X Area R -38 Vented 0.027 Above Grade Walls X Area U- Factor R -21 0.056 2176 Floors X Area U- Factor R -30 0.029 P1 Below Grade Walls X Area U- Factor 2' Depth Walls 0.042 3.5 Depth Walls 0.041 7' Depth Walls 0.037 19 F Slab Below Grade 1 X Len th F- Factor 2' Depth 0.59 3.5' Depth 0.64 7' Depth 0.57 Slab on Grade X L th F- Factor R -10 2' perimeter 0.54 R -10 Full - Heated 0.55 17 Sum of UA Envelope Heat Load Sum of UA X AT Air Leakage Heat Load ((Volume X 0.6) X AT) X.018)) Building Design Heat Load Air Leakage + Envelope Heat Loss Contact Information R -P Homes LLC 253 - 405 -1869 = UA 32.0 = UA = UA 121.9 = UA 40.0 = UA UA = UA 297 15154 Btu/ Hour 10644 Btu / Hour 25798 Btu / Hour Building and Duct Heat Load 1.15 29668 Btu / Hour If ducts are located in unconditioned space: Sum of Building Heat Loss X 1.15 If ducts are located in conditioned space: Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 150% 44502 Btu / Hour Building and Duct Heat Loss X 1.50 WSEC Prescriptive Worksheet (2010 Edition) WSUEEP10 -010 Copyright 2010 KLIEMANN Heating and Air Conditioning 4703 - 116" Street E, Tacoma, WA 98446 253 - 537 -0655 / 253 -539 -3861 Fax VENTILATION AIR REPORT To Whom It May Concern: 4 -5 bed 1501- 3000sf requires 75cfm minimum continuous operation per Table M1508.2, 2009 IRC Intermittent Whole House Ventilation Integrated with a Forced -Air System, 2007 ASHREA 62 -2 -2007, Add. b 6hr cycle: 4hr ON - 2hr OFF Outside air set at 125cfm Karen Kliemann Kliemann Brothers Heating 253 - 537 -0655 0: \WSEC Code Doci; Fan Size- Ventilation Air Report 75cfm / (6 x 1.0) 751.6 = 125cfm Printed 9/17/12 KLI EMANN Healing and Air Conditioning 4703-116 th Street E, Tacoma, WA 98446 253 - 537 -0655 / 253 - 539 -3861 Fax VENTILATION AIR REPORT To Whom It May Concern: 4 -5 bed 1501- 3000sf requires 75cfm minimum continuous operation per Table M1508.2, 2009 IRC Intermittent Whole House Ventilation Integrated with a Forced -Air System, 2007 ASHREA 62 -2 -2007, Add. b 6hr cycle: 4hr ON — 2hr OFF 75cfm / (. 6 x 1.0) 75 1.6 = 125cfm Outside air set at 125cfm Karen Kliemann Kliemann Brothers Heating 253 - 537 -0655 O:IWSEC Code Doos \Fan Size - Ventilation Air Report Printed W?J12 KLI EMAMM H o e f i n g and Air Conditioning 4703 — 116" Street E, Tacoma, WA 98446 253- 537 -06551 253 - 539 -3861 Fax DUCT LEAKAGE TESTING To Whom It May Concern: Kliemann Brothers Heating will conduct a duct seal test when ductwork is complete and will have onsite a Duct Leakage Affidavit detailing the test results in accordance with WSEC 503.10.3 Sealing. Karen Kliemann Kliemann Brothers Heating 253- 537 -0655 0 /WSEC Code Docs/Duct Leakage Test- Jurisdimon Letter 3 -22 -12 KLIEMANN Heating and Air Conditioning 4703-116 th Street E, Tacoma, WA 98446 253 - 537 -0655 / 253- 539 -3861 Fax DUCT LEAKAGE TESTING To Whom It May Concern: Kliemann Brothers Heating will conduct a duct seal test when ductwork is complete and will have onsite a Duct Leakage Affidavit detailing the test results in accordance with WSEC 503.10.3 Sealing. Karen Kliemann Kliemann Brothers Heating 253 - 537 -0655 ONJSEC Code Docs/Duct Leakage Test- Jurisdiction Letter 322 -12 Printed 8122/12