Loading...
July 16 2003 Northwest Testing Company, Inc. CONSTRUCTION TESTING and INSPECTION ENVIRONMENTAL CONSULTATION and ASSESSMENT FIELD INSPECTION REPORT CLIENT:DATE: Mountain West Senior Housing LLC July 16/17, 2003 PROJECT:REPORT NO: Rosemont Retirement & Assisted Living 05 CONTRACTOR:PROJECT NUMBER: Maddox Construction 0306.9 PERMIT NO: INSPECTOR: 6957 Mark Robinson July 16: Inspector Mark Robinson on site, 12:30 pm, for inspection of forms and reinforced concrete placement. Partly cloudy, 63 degrees. Contractor places concrete for the exterior continuous foundation walls grid line E (4.5) east to 9.2 (C.2); and SW elevator foundation slab. All areas approved for concrete per structural notes on sheet S1.0, plan notes schedules on sheet S1.1A, shear wall anchor schedule and elevator detail 14 on sheet SD.1. Concrete is placed by truck chute at a 4.5” slump and is vibrated for consolidation. One set of compressive strength test specimens is made on the placement of 9 yards and is stored in the field away from the work area for pickup tomorrow. See Report of Concrete Test Specimens for further details on today’s placement. Inspector reviews plan notes and thickened footing details in preparation for tomorrow’s floor slab placement north of line H. At this time the vapor barrier is in place, taped and sealed and envelopes the foundation wall. Reinforcing placement approximately 85% complete. All completed areas appear well constructed and ready for concrete. July 18: Inspector Mark Robinson on site, 6:30 am, for inspection of forms and reinforced concrete placement. Sunny, 52 degrees. Contractor places concrete for the floor slab north of grid line H. Graded at 4” uniform depth. The #3 reinforcing bar is in place at 18” on center each way and supported mid-way in slab. Thickened wall footings and pads in place, sized and reinforced per schedules on sheet SD.1. Vapor barrier in place with all edges and mechanical penetrations taped and sealed, and placed to envelope foundation wall. All subgrade conditions are again well prepared. Concrete is placed by pump at a 5” maximum slump and is vibrated for consolidation in thickened wall footing areas. Two sets of compressive strength test specimens are made on the placement of 85.5 yards and are stored in the field away from the work area for pickup tomorrow. See Report of Concrete Test Specimens for further details on today’s placement. NORTHWEST TESTING COMPANY, INC. Mark Robinson Mark Robinson Professional Geologist Registered Site Assessor cc: Susanna Owens, Greg Elmore, Doug Meltzer, Gary Carlson, John Maddox PO BOX 11581 OLYMPIA, WASHINGTON 98508-1581 PHONE or FAX (360) 866-3647