July 25 2003
Northwest Testing Company, Inc.
CONSTRUCTION TESTING and INSPECTION
ENVIRONMENTAL CONSULTATION and ASSESSMENT
FIELD INSPECTION REPORT
CLIENT:DATE:
Mountain West Senior Housing LLC July 25, 2003
PROJECT:REPORT NO:
Rosemont Retirement & Assisted Living 06
CONTRACTOR:PROJECT NUMBER:
Maddox Construction 0306.9
PERMIT NO: INSPECTOR:
6957 Mark Robinson
Inspector Mark Robinson on site, 6:40 am, for inspection of forms and reinforced concrete placement.
High overcast, 52 degrees.
Contractor places concrete for the floor slab north of south of grid line H, west of grid line 4.2.
Graded at 4” uniform depth. The #3 reinforcing bar is in place at 18” on center each way and
supported mid-way in slab. Thickened wall footings and pads in place, sized and reinforced per
schedules on sheet SD.1. Vapor barrier in place with all edges and mechanical penetrations taped
and sealed, and placed to envelope foundation wall. All subgrade conditions are well prepared.
Concrete is placed by pump at a 5” maximum slump and is vibrated for consolidation in thickened
wall footing areas. Three sets of compressive strength test specimens are made on the placement
of 142 yards and are stored in the field away from the work area for later pickup. See Report of
Concrete Test Specimens for further details on today’s placement.
NORTHWEST TESTING COMPANY, INC.
Mark Robinson
Mark Robinson
Professional Geologist
Registered Site Assessor
cc: Susanna Owens, Greg Elmore, Doug Meltzer, Gary Carlson, John Maddox
PO BOX 11581 OLYMPIA, WASHINGTON 98508-1581 PHONE or FAX (360) 866-3647