June 19 2003
Northwest Testing Company, Inc.
CONSTRUCTION TESTING and INSPECTION
ENVIRONMENTAL CONSULTATION and ASSESSMENT
FIELD INSPECTION REPORT
CLIENT:DATE:
Mountain West Senior Housing LLC June 19, 2003
PROJECT:REPORT NO:
Rosemont Retirement & Assisted Living 01
CONTRACTOR:PROJECT NUMBER:
Maddox Construction 0306.9
PERMIT NO: INSPECTOR:
6957 Mark Robinson
Inspector Mark Robinson on site, 8:45 am, for inspection of forms and reinforced concrete placement.
High overcast, 60 degrees.
Contractor places concrete for the exterior continuous building footings south of grid line 10.6 (no
column pads placed). Inspector meets with project superintendent and obtains a set of building plans.
Inspector reviews mix design and structural notes on sheet S1.0, plan notes and schedules on sheet
S1.1B, and relevant details on sheet 3SD.1. Inspector notes that the sub-contractor (Finishing Edge) is
reinforcing the holdowns locations with two vertical #4 hooked bars per detail 3/SD1. Today the 24”
length holdowns have to be inserted into the footings (mark numbers 3 and 4). Inspector notes one
location where holdown is missing. This is corrected prior to concrete placement.
Concrete is placed by truck chute at a 4.5” maximum slump and is vibrated for consolidation. One
set of compressive strength test specimens is made on the placement of 22 yards and is stored in
the field away from the work area for pickup tomorrow. See Report of Concrete Test Specimens
for further details on today’s placement.
NORTHWEST TESTING COMPANY, INC.
Mark Robinson
Mark Robinson
Professional Geologist
Registered Site Assessor
cc: Susanna Owens, Greg Elmore, Doug Meltzer, Gary Carlson, John Maddox
PO BOX 11581 OLYMPIA, WASHINGTON 98508-1581 PHONE or FAX (360) 866-3647