Loading...
20120299 Permit Pkg 11062012 dF TNg�y� City of Yelm Permit No.: 20120299 �� �~� Community Development Department Issue Date: 11/06/2012 (Work must be completed within 180 days) Building Division Phone: (360)458-8407 L �vI�RM�NGiON Fax: (360)458-3144 Applicant: Name: FREESTONE Phone: 253-896-1300 Address: 6820 20TH ST E STE A FIFE WA 98424 Property Information: site Address: 15449 CHAD DR SE 182 Owner: FREESTONE INC Assessor Parcel No.: 41610018200 Subdivision: CHERRY MEADOWS Lot: 182 Contractor Information: Name: FREESTONE Phone: 253-896-1300 Address: RICK CARLILE 6820 20TH ST E STE A FIFE WA 98424 Contractor License No.: FREESI*969NZ Expires: 1/24/2011 Project Information: Project: NEW RESIDENTIAL BUILDING Description of Work: LOT 182, PLAN 2379 Sq. Ft. per floor: First 984 Heat Type(Electric, Gas, Other): GAS Second 1395 Third Garage 360 Basement Fees: Item Contractor Fees NEW RESIDENTIAL BUILDING FREESTONE $16,367.45 MECHANICAL KLIEMANN BROS. $ 78.25 PLUMBING PELTRAM PLUMBING $ 118.00 TOTAL FEES: $16,563.70 Applicant's Affidavit: OFFICIAL USE ONLY I certify that I have read and examined the information contained within the application and know the same to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of #Sets of Prints: Yelm regulation � cluding those governing zoning and land subdivision, and in addition,all covenants, easements d r trictions of record. If appl ing as a contractor, I further certify that I am currently Final Inspection: registered i tate of W ingt . Signature Date ! � � �. Date: Firm By� Cit� of Y�lm t;36 ) 45�1—�40� ��EC#: 0()1 t79H8�a 11/Q6,'2012 fl:5fi AM O�F�: CC1 TERM: OQ1 REF#: 1604 Tf�AN: 33.00i0U BUILDING f'Ekt�ITS 201202.99 16,5G3.7(.1CR FREESTONE 15449 CHAU DR S� 182 �Ll�—RES1 16,36�1.45CI� MECH 78,7_5CR PL 118.00C� TRAN: 33.ii0UU BLIII.DiNG P�Rh1IT�� 2.U1202�8 16,349,C30GR 1=�EC�T�]IVE 15443 CHAD �)f2 SE 183 BL�—RES1 1Fi,15`l,75Cf� M�CH 78,25CR PL 110.00CR Tf�RN; 33,�UU0 k�UILC�ING PE�tM�fS 20i202�7 16,563.7CCf� F�REESTONE 15437 CHAI� DR 5E 18� BLD—RES1 1C�,367.45CR MECN 7�,25CR PL 11�3.00CR Tf�l�N: :�3.���(�G(l �Uil_CiING PEkMT�IS 2012U194 16,349,�OC{2 FC�EESTt)NE 15431 t;FfAD DR SE 18� 8LD—RE51 76,152.75CR MECH 78.2�CR Pl. 118.00CR �fENDERED; 65,E325,40 CWECK AH'�'LIE(); 65,825.40— CHANGE: _._.�._...___.____�.�0 YtLM COMMUNITY SCHOOLS PO BOX 4T6 YELM WA 98597 �;lerk: Croy Ter,rinal : 1 Recei pt: 19472? Manual Receipt: NFREESTuht NFREESTONE FREESTD�JE, LLC 6820 20TH ST E SUIrE A FIFE, WA 98424 11/tiJ'ZG1� 8:41 AM i�tY--Item_�___._____� _. Price 1 CNF MITIGATIuN 3015.00 MITIGATION 03-021 / lot 182 I 15449 Chad DR SE;YeIm 1 UPF MITIGATI�N 3015,00 MITIGATION �3-021 l lat 183 �' 15443 Chad DR SE;YeIm 1 CPF MITIGATIuN 3015.00 MITIGATION �3-Q21 / lot 184 / 15437 Chad DR SE;YeIm 1 CFF MITIGATIDN 3015.00 MITIGATION 03-021 / Lot 185 / 15431 Chad DR SE;YeIm Supfiotal : 12060.00 Tax: 0.00 Tatal ; 12060.00 �h�ck 12080.00 1605 i,hanae Due: 0.00 THA�IK YQU G'�i�� �� CITY OF YELM RESIDENTIAL BUILDING PERMIT APPLICATION FORM Project Address: �J�^�, 9 • � Parcel#: `4'��I D� I ba�Q� Subdivision: 4 ot#:��. Plan#:�� Zoning: �Q New Construction ❑ Re-Model/Re-Roof/Addition ❑ Home Occupation Sign 0 Plumbing ❑ Mechanical ❑ Mobile/Manufactured Hom lacement 0 Ot er Project Description/Scope of Work: � ` Q_ ����f �� Project Value: ���, ��ja . Building Area (sq. ft) 13'Floorq ay 2nd FI00��� Garage �� � '�j Basement — Carport ^ -�o a, � #Bedrooms� #Bathrooms����-- Heating: A�pTHER or ELECTRIC (Circle One) Are there any environmentally sensitive areas located on the parcel? �_ /f yes, a compieted environmental checklist must accompany permit application. BUILD�NG OWNEt�NAME�: ADDRE�SS O EMAIL ' .C� CITY_��_ STATE ZIP TELEPHONE (o- �p ARGHITECT/ENGINEER UCENSE# ADDRESS a5 - EMAILj1jQQhq CqMC4 � CITY �o.�-►��� STATE ZIP � TELEPHONE GENERAL CONTRAGTOf� TELEPHONE_ SAMC� ADDRESS EMAIL � CITY 5Pr-tY��c' STATE IP F,qX__�o�.� $c�(o_dfo ep CONTRACTOR'S LICENSE# E 2 EXP DATE CITY LICENSE# 7Al PLUMBING COfVTRA�T€7!I� LEPHONE 1- ADDR SS EMAIL CITY STAT • Z P 0_�1 FAX (;ts�, Gj L-q� CONTRACTOR'S LtCENSE# O EXP DATE CITY LICENSE# � �O MECHANICAi:CONTFL4GTO,R � Ic � TELEPHONE a6 5 -O ADDR�F.SS 0 '� � _ EMAIL CITY Ict,�.pry�cL, STATE ZIP L FAX CONTRACTOR'S LICENSE#{�I,TE�lg1�0 1 RT EXP DATE�L CITY UCENSE# 'a.'1 201�{ Copy of mitigation agreement with Yelm Commurnty Schools, if applicable. I hereby certlfy that tha above InformaUon Is correet and that ths conatrucUon on,and tha oecupancy and tha uss of tha abov crlbad property wlll b�In accordanca with tha laws,rules and regulatlons of ths Stab of Washington and th• CI of elm. Appllc 's Signatur 'Z Date Owner/Contractor/Owner's Agent/ ontractor's Agent(Please ctrcle one.) All permlts are non-transferable and will explre tf worlc authorized by such permlt Is not begun withln 180 days of issuance,or if work Is suspended or abandoned for a perlod qt,1,84,d � � �' ���°%�c_��-�-_. 19 :..,,.�. �� � �� � � � 105 Yelm A�enue Weat (360) ,��_______ Yelm, WA 98597 (360)458-3144 FAR -"""-- wwta.ct.yelm.wn.ua �r,,.,,.�.b,�..�,e�� ._ _ �. , ,-�. ,��.. �,�, .�.� , ... _ �. �.�,..,a„ SCALE:1"=20' S2,00 p �O lOT r- 182 983 � 0 GY 1 N �DRYWELL � � � v � � � — � __._ � � � N � 18 x 12 CQV PATIO � pRAOIN5 f � � — � � 39' ( � � 2379 A REV j � g DIAG 54.45' � g M Q I ,.�. I C? r' a 6.5' w 39' .5' � `� f ( � � 2 CAR � �� GAF2AGE I � ( cov. � PORCM 20' s. .5'�,,�1 �CONC.T I 10'�ntr�. �. � DRIVE ;- SEPARAT€ON � � � tV OR SLEEVE �•``�..�— � :- WATER L1NE 10'UTILITY ESMT\� � ( � .�,.w, S w C�NC WALK �jZ,�a �� � � �, PI.ANTER 6' o� CURB/GUTTER � • N ����"�r_a���4�' ;�� z2 --�---� --�__- ___ _..�. :.n�:;: _ � : �- GHASD DRIV� 5� ��LL 10 _�. �.- ►`�. ��� NO 5' EAVE CONNEC7 4" PVC RO�F ENCRQACHMENT THIS �OT DRAfNS TO DRYWELL LC�T 182 — CNERRY MEADOWS �� ��'``���`�"' '�' `�:.. j� � :�: PARCEL. #: 41610Q 182 Qfl Owner: �rE,eS�Oht3 �� Gherru M�o.w�_.LLL_______ Lot 5ize: Project Addr�ss: 6820 20th 5t. � 5ufte A 5,2Q0 Sq. Ft. �54�9 CHAD DRIVE SE 253 8��300 P�escriptive Energy Code Compliance for Single Family and Duplex Housing: Zone 1 � Project Information Contact Information Freestone Plan 2379 Freestone Companies, 6820 20th St E. Suite A Yelm Fife, WA. 98424 Rick Carlile cell 253 381-6080 This set of forms has been developed to assist permit applicants documenting compliance with the Washington State Energy Code, (2009 edition). This set is for structures built under the IRC and located in Climate Zone 1. The following forms provide much of the required documentation for plan review. The details noted here must also be shown on the drawings (WSEC 104.2). This form is not a substitute for the energy code itself. To obtain a copy of the energy code, go to the following web address. http://www.energy.wsu.edu/code Glazing �2 4 a 6 lo Glazing U-Factor poor 9 Vaulted Wall Wall• int Wall• ext Slab Option Area : Ceiling2 3 Above Below Below Floors on %of Floor Vertical Overhead" U-Factor Ceiling Grade Grade Grade Grade R-49 or R-21 R-21 R-10 � I 13% 034 0.50 0.20 R-38 R-38 Int.� '['$ R-10 R-30 2, Adv. R-49 or R-21 R-21 R-10 Q II 25% 0.32 0.50 0.20 R-38 R-38 Int.� TB R-10 R-30 2, Adv. R-49 or R-21 R-21 R-10 Q III Unlimited 0.30 0.50 0.20 R-38 R-38 Int.� 1'g R-10 R-30 2, Adv. See WSEC table 6-1 for footnotes Glazing Schedule Attached to Document � Does not apply. (SEE INSTRUCTIONS) Usin� Prescriptive Option III. All glazing and doors meet maximum U-factor. Alternate heating size method submitted. � Option I or II,Glazing to floor area limit(WSEC 602.7.2} ❑ Area weighted window,skylight or door U-factor(WSEC 602.7.2) ❑ As part af the heating system sizing calculation (IRC M1401.3&WSEC 503.2.2) Radiant slab: ❑ R-10 foam insulation, continuous with thermal break (WSEC 502.1.4.9) Chapter 9 Options Total of 1 Credit Required Opt. Opt. Description 1a Hi h Efficienc HVAC Equipment 1 1A 0 _ 1b High Efficiency HVAC Equipment2 1c High Efficiency HVAC Equipment 3 2 Hi h Efficienc HVAC Distribution S stem 3a Efficient Buildin Envelope 1 3b Efficient Buildin Envelope 2 3c Super-Efficient Buildin Envelope 3 4a Air Leakage Control and Efficient Ventilation 4b Additional Air Leakage Control and Efficient Ventilation � �—,r+�—,�:��� � 5a Efficient Water Heating is 2, ti,; �� � r •. 5b High Effieciency Water Heatin J � i� 6 Small Dwellin Unit � " , �01� 7 Lar e Dwelling Unit : 8 Renewable Electric Ener ,00_kwh_____________ Total Credits 1.00 WSEC Prescriptive Worksheet(2010 edition)Zone 1 WSUEEPIO-010 Copyright 2010 , _ _ _ _ __ _ _ Glazing Schedule _ � Project Information Contact Information Freestone Plan 2379 Freestone Com anies, 6820 20th St E. Suite A Yelm Fife, WA. 98424 Rick Carlile cell 253 381-6080 Conditioned Floor Area 2379 Sum of UA for Heating System Sizing 107.4 Sum of All Glazing Areas From Below 309 Glazing to Floor Area Ratio 12.99% 602.7.2 Exception Ratio(not to exceed 1%)� Exterior poors Plan Component Door Percent Width Height Glazing Door poor ID Description Ref. U-factor Glazed Qt. Feet Inch Feet '�`n Area Area UA Ent Fiber lass Insulated IECC 0.160 1 3 6 8 20.0 3.2 1.�Q One Exempt Swinging Door<24 Square Feet 1 2 $ 6 $ 17.8 Sum of G/azing Area, Door Area, and UA (do not include exempt door) 20A 3.2 Area Weighted U= UA/Area 0.16 Sum of Area and UA for Heating system size only(include exempt door) 37.8 3.2 Vertical Glazing (Windows, Glazed doors using Exception 602.6#1) Plan Component Glazing Width Height Glazing ID Description Ref. U-factor Qt. Feet ��°n Feet �"�n Area UA L&Gr 2 Glz Vin I Low E NFRC 0.340 2 6 5 60.0 20.40 Din 2 Glz Vin I Low E NFRC 0.340 1 5 5 25.0 8.50 Kit 2 Glz Vin I Low E NFRC 0.340 1 4 4 6 18A 6.12 Nk 2 Glz Vin I Low E Super S acer SGD NFRC 0.330 1 6 8 48_0 15.84 Up 2 Glz Vin I Low E NFRC 0.340 5 5 4 100.0 34.00 Mbr 2 Glz Vin I Low E NFRC 0.340 1 6 4 24.0 8.16 Mbr 2 Glz Vinyl Low E PW NFRC 0.320 2 2 2 8.0 2.56 Mba 2 Glz Vin I Low E NFRC 0.340 1 4 4 16.0 5.44 Gr R 2 Glz Vin I Low E PW NFRC 0.320 2 2 2 6 10.0 3.20 Sum of Area and UA 309.0 104.22 Area Weighted U= UA/Area 0.34 WSEC Prescriptive Worksheet(2010 Edition) WSUEEP10-010 Copyright 2010 Overhead Glazing : ` Plan Component Glazing Width Height ID Description Ref. U Qt. Feet �"`n Feet '"°n Area UA Sum of Area and UA Area Weighted U= UA/,4rea Doube Glazed Garden Windows Section 602.7.2 Exception Plan Component Width Height ID Description Qt. Feet '"`n Feet '"`n Area UA Sum of Area Sum of Area X 3 (This total is automatically included in the glazing area total.) : Glazing UA for Heating System Size Only=Area X 0.63 WSEC Prescriptive Worksheet(2010 Edition) WSUEEPIO-010 Copyright 2010 . Simple Heating System Size: Climate Zone 1 - Project Information Contact Information Freestone Plan 2379 Freestone Com anies, 6820 20th St E. Suite A Yelm Fife, WA. 98424 Rick Carlile ce11253 381-6080 Indoor Design Temperature 70 Outdoor Design Temperature 17 _ _ _ Design Temperature Difference (OT) _ _ �T=Indoor-Outdoor Design Temp 53 Conditioned Floor Area 2379 Conditioned Volume 20016 Glazing _ Copy Sum of UA from Glazing Schedule 107 . _ _. .. Attic U-Factor X Area = UA R-49 0.027 1395 37.7 R-38 Advanced 0.026 Single Rafter or Joist Vaulted Ceilings U-Factor X Area = UA _ __ _ _ _ . R-38 Vented 0.027 � � Above Grade Walls U-Factor X Area = UA R-21 0.056 2189 122.6 Floors U-Factor X Area = UA R-30 0.029 1402 40.7 Below Grade Walls U-Factor X Area = UA 2' Depth Walls 0.042 . 3.5' Depth Walls 0.041 7' Depth Walls 0.037 Slab Below Grade F-Factor X Len th = UA _ _ 2' Depth 0.59 3.5 Depth 0.64 7' De th 0.57 Slab on Grade F-Factor X Len th = UA R-10 2' perimeter 0.54 R-10 Full - Heated 0.55 Sum of UA 308 _ _ Envelope Heat Load 16341 Btu/ Hour _ Sum of UA X 4T Air Leakage Heat Load 11457 Btu/ Hour ((Volume X-0:6)X 4T)X:018)) Building Design Heat Load 27798 Btu/Hour Air Leakage+Envelope Heat Loss Building and Duct Heat Load 1.15 31968 Btu/ Hour If ducts are located in unconditioned space:Sum of Building Heat Loss X 1.15 If ducts are located in conditioned space:Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 150% 47952 Btu / Hour Building and Duct Heat Loss X 1:50 WSEC Prescriptive Worksheet(2010 Edition) WSUEEP10-010 Copyright 2010 ___ _ _ _ _ ___ _ _ ' WELLER CONSULTING ENGII�?EERS, P.C. 2(92S 8th Place W• Bothell,WA 98021 • Ph(425)488-9868 • Fax(425)486-6715• ���cengr@comcast.net , TO: City of Yelm Building Department October 15,2012 ' Building Official RE: Plan 2379,Lot 182,"Cherry Meadows" Weller Consulting Engineers,P.C. Job# ]0-022 The previously submitted structural calculations by Weller Consultin� Engineers' P.C. for plan 2379 will not be affected due to the addition of the covered patio. Please see attached calculations f'or the covered porcl�beams. �� ��`::s r�"��..,.... ��.��,J , l �`'`ei,��YY.tStf����, �� 1�,,,,�. �r�,�-:,.'•'`.� ���� ,r,"'� r' � ��� � ��r�i �.�.,.� B � �"" ..>�,._ r .� � �v5�0 �:;oe In Y� ���{7\�iP`(j... g4O� �Vflb Mark F. Weller,P.E. �."f n `~1"—j�' �c;�';�� �. ��fca��;�i�� •�' President ""���-;�-•+�'� �EKU�Yi�� V�YI:^rSi�g r'� __'•� ���.���....._��..��...�.�.� �.a�_�..�.-.+.... r� r1 ���1��n�� � �I� 1:� `�?- �� l/ c_=. � �i ,s r:�.+ L�l1el_ �Y:-----------------�-- BeamChek v2009 licensed fo:Weller Consulting Engineers,P.C. Reg#5234-65779 FREESTONE ROOF FRAMING PORCH BEAM Date:8/07/12 ! f 3-1/8x 10-1/Z OLB 24F-V4 OF/DF Lu�0.0 Ft n i' n NDS 2005 Min Bearing Area R1�2.3 in' R2=2.3 in' (1.5)DL Defl= 0.44 in Recom Camber�0.68 in � 8eam Span 18.0 ft ReacUon 1 LL 900# Reaction 2 LL 900 it Beam Wt per ft 7.97# Reactlon 1 TL 1512# Reaction 2 TL 1512# 8m Wt included 144 p Maximum V 1512# Max Moment 6803'# Max V(Reduced) 1365# TL Max Defl L/240 TL Actual Defl L/248 LL Max Defl L/380 LL Actual Defl L/497 A 'ltnbutes SecGon in Shear in TL Defl in LL Defl Actual 57.42 32.81 0.88 0.43 Critical 29.58 7.42 0.90 0.60 Statua OK OK OK OK Ratio 52% 23% 98°r6 72% Fb si Fv s� E sf x mil Fc1 si Values Reference Valuea 2400 240 1.8 650 Ad usted Valuea 2760 278 1.8 650 ' Adrustmenfs Cv Volume 1.000 Cd Duratlon 1.15 1.18 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 CI StabBity 1.0000 Rb=0.00 Le=0.00 Ft �oads Unfform LL:100 Uniform TL: 180 =A Uniform Load A R1 =1512 R2=1512 SPAN 3 18 FT Unifortn and partial uniform loads are Ibs per fineai ft. . BeamChek v2009 licensed to:Weiler Consulting Eng/neers,P.C. Reg#523465779 . FREESTONE ROOFFRAMING PORCH BEAM Date:8/07/12 i c8on 3-1/8x 10-1/2 GLB 24F-V4 DFIOF Lu=0.0 Ft ndit/o NOS 2005 Min Bearing Area R1=4.2 fn' R2�2.0 in' (1.5)DL Defl= 0.33 In Recom Camber=0.49 in Data Beam Span 12.0 R ReacUon 1 LL 1050# Reactfon 2 LL 450# Beam Wt per ft 7.97# Reaction 1 TL 2738# Reaction 2 TL 1272# Bm Wt Inciuded 98# Maximum V 2736# Max Moment 7384'# Max V(Reduced) 2344# TL Mex Defl L/240 TL Actua�Defi L/338 LL Ma�c De8 l/380 LL Actual Defl L/>1000 Atfributes SecUon in' Shear in TL Defl in Ll Defl Actual 57.42 32.81 0.43 0.10 Critical 32.02 12.74 0.80 0.40 Status OK OK OK OK Ratio 56% 39% 71% 25% Fb si Fv si E si x mil Fcl s( Values Reference Valuea 2400 240 1.8 650 Ad usted Values 2780 276 1.8 850 Adiustments Cv Volume 1.000 Cd Duration 1.15 1.15 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 CI Stabifity 1.0000 Rb=0.00 Le=0.00 Ft Loads Point TL Distance Par Unit LL Par Unif TL Start End B=1512 4.0 225 H=360 0 4.0 50 1=80 0 12.0 I �H� Pt loads: B R1 =2738 R2�1272 SPAN=I2FT Uniform and partial uniform loads are Iba per Uneal ft. f ��;� .'�f�' -; F �� '�i_�i�;E�-1Ef��1 — �'�F=' L � '(��' 'EF'E'� F' � T' ; �-� � _ v � i � 2009 I.R.C. I.R.C. SEC. R806.2 — VENIILATION THE NET FREE VEN11LAl1NG AREA SHALL NOT BE LESS THAN 1 / 150 OF THE AREA OF SPACE TO BE VENTILATED, EXCEPT THAT THE AREA MAY BE 1 / 300, PROVIDED AT LEAST 507 & NOT MORE THAN 80% OF THE REQUIRED VENTILATING AREA IS PROVIDED BY VENTILATORS LOCATEd IN THE UPPER PORTION „ OF THE SPACE TO BE VENTILATED AT LEAST 3 FEET ABOVE EAVE VENTS WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE VENTS AND VENTING RIDGES. '���� -a>� tr�= a��;w ' er,c�ir�ee�Review EAVE VENTS SHALL BE COVERED WITH CORROSION—RESISTANT METAL MESH WITH MESH _..;;.,, .,�:- OPENINGS OF t/4" IN DI�IENSION. _ r, ,_ - � � � TOTAL ROOF AREA (Sq. Ft.): 216 =� ^ SCREENED VENT AREA (Sq. Ft. w/ AREA REDUCTION): 0.34 � REQUIRED AREA (TOTAL Sq. Ft. / 2): 108 ' REQUIRED ROOF AREA DIVIDED BY 300 0.36 REQUIRED ROOF AREA DIVIDED BY SCREENED VENT AREA 1.06 TOTAL VENTS REQUIRED (ROUNDED UP): 2 12" 18'-0° �2„ GABLE W 12" RAKE N GABLE E D IRDER TRUSS 4:12 4:12 � � a � a w W 00 cn m a N a a � w o � � ° ° i ° � o N � o �v� mo w N d� HUC410 HANGAR(2 PLCS) 19'-0" 6" 18'-0" 6„ � 4X4 DF�2 W/ 4X4 DF#2 W/ ACE4 & AB44 ACE4 & AB44 PIER PAD 18"0. PIER PAD 18"0' j x 8" THK. TYP. x 8" THK. TYP. j � v � N � e N m m �: O U` � cD N ^ OPT. COVERED PATIO " � 0 -- - o X " X � - W M ` (`� HUC410 HANGAR(2 PLCS) _�� �� I . ,� ' _ � �� i���� � � �� ! �, I I ��._ e" = 1'-0" --------------------------- ---- Project: P'°�� Freestone Com anies p 6820 20th Street E Suite A, Fife WA 98424 Date: 253.896.1300 9/14/12 www.freestonecompanies.com U � M `- � � � O � M N � � N N �N, � Q � � V � � d' � � � U•Q N � � N _ � � � � � N � C� � �+ U � � � -� � � � � N � � � o .> q � � � � � � �' � � � � � �� p� °' °' - � �+ � � � m � O ° •`� � in ��'. � � �' � � � c �I.l p�j � � �� ��l q ��,,, � ((f V � � � � � N •� N � � � Q 3 � ai � � w w � � � � �3 � cn ° � ''Q- �a � w N � �� � �' VJ Q � � � 'v � O 4� � w � °° � ° a? V � = prn � = � wC� .S -°� o V F- o Q> rn � � Z .�n ca f� N > N � w � � � W O W N N � J � � LL � �' � � C�p L.L N � J V � J � � a Q � � � N ,.0 � � �- � � N cn Z O � . . N � +, � O � N � ',+_.� (B a � � � E J U � �U '�'� 'D � 'D � Q p � � p Q 'a � � N V � * Z Q C �� .. T � L L � � U� � L� �.. �'. � .� � � � � � � •� � � 00 O O C� � Q (/) m Mar. 25. 2013 8: 33AM Kliemann Bros HVAC No. 0599 P, 2 � t�- /G��2 . . , : � � "�,� 'L '�Z ; 4�• , � • Duct Lcakage Af�davit ' Perrnit#: House address or tot number:�������_��„�__ c�:y: ._�.�� _ z�P: _ 9�"s��Z_ Cand. �loor Area(ftZ): � ��_ Source(circle one): Pla s` Estlmated Measured ❑ Duct tlghtness testing is not required far this restdence per exceptlons listed at the end af thls document Alr Handler in conditioned space? �yes�no Alr Handler present during test?�yes❑na Circle Test Method: �eaksge to dutside Total�ea e Maxlmum duct/eakage: Post Constructfon,total duct leakage: (Floor area x.08)�__ C�MQ25 Pa Post Gonstruction,leaka8e to oufdoors: (floor area x.06)� __CFMQ25 Pa Rough-In,toEal t�uct leakage wlth afr handler instal[ed: (floor area x.06) =�GI�CFM@25 Pa Rough-In,totat duct leakage with a9r handier not Instafled: (floor area x.Q4)=____,,,_,CFMQa 25 Pa Test Result: ��� CFM c(�25Pa Ring(circle one if appllcabfe): Open 1 � 3 Duct Tester I.ocatian_____��_� _ Pressure Tap Locstion:��!°4�`�L� �/�' I certify that these duct feakage rates are accurate and determinsd using standard duct testing protocol. Company Name:_����,_,��—Technictan: �_ �!1...L����� (�'�� /� Techn(cian Slgnature: `/ � ^ _pate:_ ��_ phone Number:��Q�� Washington 3tale Energy Code referance; 505.10.5 Saaling.All ducts,air handlers,filter boxee,and bullding cavilles used as ducts shall ba sealed.Joihla and seams shall comply wilh SeGlon M1601_9 of lhe IntemaBonal Residential Coda or 603.8 ot lhe Jnlernatlona/Mechanlca!Code. Ducl tighlnesa CeeUng bh�ll be conducted to Verify thaf Iha ducts are sealed.A signed affidavit documenting lhe test refiults shall be provlded to Ihe Judsdiclion having aulhority by the tesfing agenC.When rAqulrod by the bullding offlclal,lhe test shall be oonducted tn lhe presAnce of department slaff. 6xc�aptlons: 1.Duct Ughlneas taeC le no�Yequlred if the a!r handler and all ducis are localed Wilhin condilfon�space_ 2,Duct lesttng is nol required ff lhe furnece 18 8 nondlrect vent type combusiton apptiance inslalled in an unGOndltloned space. A mexlmum of six feel of connected duchvork in lhe uncondltlohed space!s allowed.All addillonal supply and return ducts ahafl be Wllhin lhe condilloned space.Ducts oulside lhe condllioned epace she[I be seafed wlth a mastfc lype duck sealant and Insufated on the eMetfot Wlth R 8lnsulallon for above grade ducts and Rd"i water resi8lant ineulatlon when wllhin a slab or earth. �/,��'S'�A��� � �I INS ULATI ON � ��o ti�ti� NORTHWEST ��GH��� Insulation Certificate/Blower poor Test Form � / �Z Batts&Blankets Thermal Performance(Attic Application) When installed in accordance with the manufacturer's The stated thermal resistance(R-value)is provided by installing in accordance with the manufacturer's recommendations,Knauf Batts&blankets will provide instructions,the required number of bags per 1,000 sq.ft.of net azea,at not less than the labeled minimum the full R-value.- thickness.Failure to install both the required number of bags&at least the minimum thickness will result in lower insulation R-value. To obtsin an tnstatled insulation To obtain an The number of Contents of this bag The WeightlS�of Tnstalled insulation insularian resistance should nat be less insulation bags/1,000 SF of ne should not coyer more instatled ins�[ation st�outd not be less R-Value of than: resistance area shouldnot be than: should noY be less than: than: -Value)of: R-38 HD 10.25" R-60 29.7 33.6 SF .9521bs. 19.750" R-38 12.00" R-49 ^23.5 42.5 SF .7531bs. 16.375" R-30 HD 8.25" R-44 20.9 47.8 SF .6701bs. 14.875" R-30 10.00" R-38 17.8 56.2 SF .5691bs 13.000" R26 9.00" R-30 13.6 73.3 SF .4371bs 10.375" R-22 6.50" R-26 11.8 85.0 SF .377 lbs 9.125" R-21 HD 5.50" R-22 9.8 102.2 SF 313 Ibs 7.750" R-19 6.25"** R-19 8.4 1193 SF .268 lbs 6.750" R-15 HD 3.50" R-13 5.7 175.3 SF .183 lbs 4.750" R-13 3.50" R-11 4.7 210.8 SF .1521bs 4.000" R-11 3.50" Bag Weight-Nominal 301bs,Minimum 291bs.This product conforms to the performance requirements of ASTM C 764, R-8 2.50" Type 1,&cancelled Federal Specification HH-1-1030B,Type 1,Blass B.R-Values are determined in accordance with **R-18 in a 5.5"cavity.Conforms to ASTM C 687&C 518."R"means resistance to heat flow.The higher the R-value,the greater the insulation power.To get the C665&Federal Specification HH-1-521F inarked R-value,it is essential that the insulation be installed properly.If you do it yourself,get instructions&follow them. To achieve labeled R-value,this product must be applied with a pneumatic blowing machine&a corrugated hose with a minimum.25"internal corrugation,a minimum length of 150 ft.&a diameter of at least 3".Coils in the hose should not be less than 36"in diameter.Acceptable material feed rate is 5-35 lbs./minute.Recommended feed rate is 15-25 Ibs./minutes. Builders Insulation Statement. Batts and/or blankets have been installed in conformance with the above 2009 WSEC Residential Enerev Comoliance Certificate-Buildine Air Leakaee recommendations to rovide a thermal resistance of.... R-V ue Standard Buildin &Test Condition: Comments: Attic Area R- R-49 Date: 3 y�j l Ext.Walls R- R-21 Time Inter.Walls R- R-11 Indoor Tem : S rinkler Tentin R- R-8 Outdoor Tem : Knee Walls R- R-21KF Floor Area(s 8) Completed as of. Buildine Air Leakaae Tar¢et: SLA Less Than 0 00030 Installers Name Print: ��w Test#1-Depress � Press Pretest Baseline Pressure (Pa) Installers Name Sign: Bld Press.(I'a Flow Rin Fan Press. Pa Flaw cfrn SiteAddress: ���_I t�tA1�W �Q. �j� "c��t w� a$S�� Post Test Pressure: Fan Model/SN: .�r- Results:SLA(Specific Leakage Area): ���?.( Home Builders Signature: Test#2-Depress Press Pretest Baseline Pressure (Pa) Home Builders Address: Bld Press. a Flow Rin Fan Press. a Flow cfin) Insulation Contractor. Insulation Northwest LLC Post Test Pressure: Fan Model/SN: P.253-846-0121 P.O.Box 732069 Results:SLA(Specific Leakage Area): F.253-846-8096 Pu allu WA.98373 Affidavit: I certify that this Specific Leakage Area is accurate&determined using Blower poor Test Standazd 502.4.5 Building Air Leakage Testing. Technician Name Print: Technician Name Sign: ,,`5�A TjQ � ` �� I1�TSLTL �. TIO � ��o w��� NCJRTHWEST ��I'H��� ELOWER DOOR TEST RE5ULTS FORM /�� Customer Information: Buildin & Test Condition�: CustomerBuilderName: �(Z�S'ZD+I�1� Date: �JZ3 1 Z013 DevelopmentName: G�A.F,-gtr2.�y I�(�#.-OOUJS Time: d�,9'9' I ,.,0 Address/Lot#: �S q'q'� C�+lI�c9 �Q. �.�. Indoor Temp: t�U e City/State/Zip: y�.t►M� W Q* ��S q� Outdoor Temp: � � Phone: Volume(sq ft): Email: Floor Area(sq ft): Comments: Surface Area(sq ft): Z3�9 S� #Bedrooms: #Occupants: Wind Shielding: Test# 1 Test#2 Depress: � Press: Depress: Press: Pretest Baseline Pressure: (Pa) Pretest Baseline Pressure: (Pa) House/IJnit Pressure: ��+ •� (Pa) House/[Tnit Pressure: (Pa) Flow Ring Installed: � Flow Ring Installed: Fan Pressure: v�� (Pa) Fan Pressure: (Pa) F.low(cfin>: I 3 3� Flow(cfin): Post Test Baseline Pressure: (�'a) Post Test Baseline Pressure: (Pa) Fan Model/SN: �.3 Fan Model/SN: Results• Results• SLA: � OOQ2� SLA: . CFM50: CFM50: ACH50: ACH50: CFM50(sq ft): CFM50(sq ft): 1VIpls Leakage Ratio: - Mpls Leakage Ratio: