20120303 Permit Pkg 10252012 ,���''��� City of Yelm Permit ►vo.: 20120303
� �
� � Community Development Department Issue Date: 10/25/2012
(Work must be completed within 180 days)
Building Division
Phone: (360)458-8407
YE M
�`�S"'"`T"" Fax: (360)458-3144
Applicant:
Name: MATHEW THOMPSON Phone: 254-319-4746
Address: 9929 COCHRANE AVE., SE
YELM WA 98597
Property Information:
Site Address: 992g COCHRANE AVE Owner: MATHEW THOMPSON
Assessor Parcel No.: Subdivision: JOHN'S MEADOWS Lot:
Contractor Information:
Name: MATHEW THOMPSON Phone:
Address:
9929 COCHRANE AVE., SE
YELM WA 98597
Contractor License No.: Expires: 0/00/0000
Project Information:
Project: MECHANICAL
Description of Work: INSTALL PELLET STOVE
Sq. Ft. per floor: First Heat Type(Electric, Gas, Other):
Second
Third
Garage
Basement
Fees:
Item Contractor Fees
MECHANICAI MATHEW THOMPSON $ 29.50
TOTAL FEES: $ 29.50
ApplicanYs Affidavit:
I certify that I have read and examined the information contained within the application and know the same OFFICIAL USE ONLY
to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of #Sets of Prints:
Yelm regulations including those governing zoning and land subdivision,and in addition,all covenants,
easements and restrictions of record. If applying as a contractor, I further certify that I am currently Final Inspection:
registered in the St e of Washington.
Signature �� �' (�' Dat��� �(/� �G/� Date:
Firm gY=
�
Cit� af Y�lm
(36 ) 45$-8402
REC#: OOl0yQ51 lU/25/2012 3;37 PM
OPER; CO TERM: 001
REF#: 1304
I�kAN: 33.OUC�U BUILUING PERMITS
20120303 29.50CF2
THOMPSON, MATHEW
9929 GOCHRANE AVE
MECH 29,50CR
ikN�EREG: 29.5U CHECK
�f'PLIED: 29.50-
CHANGE; �� 0.00
, 'R
,�� ���� � ��3
CITY OF YELM
RESIDENTIAL BUILDING PER����A�IgO���M
Project Address: CQG�/b�v�-���. '7��arcel#:
Subdivision:..��� Lot#: Plan#: Zoning:
� New Construction i Re-Model/Re-Roof/Addition � Home Occupation Sign
' Plumbing v�ilechanical Mobile/Manufactured Home Placement f�(Other
Project Description/Scope of Work: ��! ���V'e--
Project Value:��, �a�(�O
Building Area(sq. ft) 1S` Floor � 2nd Floor Garage Deck
Basement Carport Patio
#Bedrooms� #Bathrooms o�!$ Heating: GAS/OTHER or ELECTRIC(Circle One)
Are there any environmentally sensitive areas located on the parcel?
/fyes, a completed environmental checklist must accompany permit application.
BUILDING OWNER NAME: ' L•
ADDRESS ✓L. EMAIL ���,.r 7 �co^�"'
CITY STATE�ZIP '7 TELEPHONE / — �/ �60����1 �
ARCHITECT/ENGINEER LICENSE#
ADDRESS EMAIL
CITY STATE ZIP TELEPHONE
GENERALCONTRACTOR TELEPHONE
ADDRESS EMAIL
CITY STATE ZIP FAX
CONTRACTOR'S LICENSE# EXP DATE CITY LICENSE#
PLUMBING CONTRACTOR TELEPHONE
ADDRESS EMAIL
CITY STATE ZIP FAX
CONTRACTOR'S LICENSE# EXP DATE CITY LICENSE#
MECHANICAL CONTRACTOR TELEPHONE
ADDRESS EMAIL
CITY STATE ZIP FAX
CONTRACTOR'S LICENSE# EXP DATE CITY LICENSE#
Copy of mitigation agreement with Yelm Community Schools, if applicable.
I hereby certify that the above information is correct and that the construction on,and the occupancy and the use of the
above described property will be in accordance with the laws,rules and regulations of the State of Washington and the
City of Yelm.
������"� �� ��� �G�' �oI�
Applicant's Signature Date
Owner/Contractor/Owner's Agent/Contra r's Agent(Please circle one.)
All permits are non-transferable and will expire if work authorized by such permit is not begun
within 180 days of issuance, or if work is suspended or abandoned for a period of 180 days
�
105 Yelm Auenue West (360)458-3835
Yelm, WA 98597 �` ^ ��'�"'�Tj�`; (360)458-3144 FAX
www.ci.yelm.wa.us �P ���� v '-�" ��
�� � - `�� ? �;
4Ci i!_ �
BY:__,.........R_�. -�--
� INSTALLATION & OPERATION MANUAL
MODEL NUMBERS: 25-PDVC 55-SHP10 55-TRP10
Thank you for purchasing this product from a fine line of heating equipment. We wish you many
years of safe heating pleasure with your new heating appliance.
Save These Instructions.
IMPORTANT: IF YOU HAVE A PROBLEM WITH THIS UNIT DO NOT RETURN IT TO THE
DEALER. CONTACT TECHNICAL SUPPORT @ 1-800-245-6489.
Mobile Hoine Use:
These freestanding pellet units are approved for mobile home or doublewide installation with
outside combustion air hook-up. See "Flue System" section of manual.
Mobile home installation should be in accordance with the Manufactured Home and Safety
Standard (HUD), CFR 3280, Part 24.
� WARNING: Do Not Install in Sleeping Room
€ CAUTION: The structural integrity of the mobile home floor, wall and ceiling/roof
; must be maintained.
�
,
f
� P/ease Note the Fol/owinq Precautionarv Statements:
NOTE: WE DO NOT RECOMMEND PELLET STOVES AS YOUR ONLY SOURCE OF HEAT.
England's Stove Works highly recommends the use of smoke detectors and Carbon Monoxide
detectors with any hearth product, including this unit. Follow all manufacturer's instructions when
� using smoke or Carbon Monoxide detectors.
f
�
!
� CAUTION: Please read this entire manual before installation and use of this pellet
fuel burning room heater.
Keep children, furniture, fixtures, and all combustible materials away from
�'� any heating appliance. Refer to this owner's manual for all clearances to
combustible materials.
WARNING: USE OF OUTSIDE AIR IS MANDATORY WITH THIS UNIT.
� DO NOT OPERATE UNIT WITH HOPPER OPEN. LID MUST BE SHUT AND TIGHTLY SECURED.
� DO NOT OPERATE WITH DOOR OPEN
SAFETY NOTICE
FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE,
BODILY INJURY OR EVEN DEATH. FOR YOUR SAFETY AND PROTECTION, FOLLOW ALL
THE INSTALLATION INSTRUCTIONS. CONTACT YOUR LOCAL BUILDING OR FIRE OFFICIALS
FOR RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS (INCLUDING
PERMITS) IN YOUR AREA.
Questions? Need Parts or Options? ��s��►��•.a°��=i�r����-siu�is.ci}r��
�NieRr��
Rev. 4/5/2012
� � �
� �`-=��
'� � ,., US � � I �.,�
d�ock t�e��
VENT TERMINATION CLEARANCES
A) MIN.4-FT CLEARANCE BELOW OR BESIDE ANY DOOR OR WINDOW THAT OPENS.
B) MIN. 1-FT CLEARANCE ABOVE ANY DOOR OR WINDOW THAT OPENS.
C) MIN. 2-FT CLEARANCE FROM ANY ADJACENT [3UILDING. �
D) MIN. 7-FT CLEARANCE FROM ANY GRADE WHEN ADJACENT TO PUBLIC
WALKWAYS.
E) MIN. 2-FT CLEARANCE ABOVE ANY GRASS, PLANTS,OR OTHER COMBUSTIBLE
MATERIALS.
F) MIN. 3-FT CLEARANCE FROM A FORCED AIR INTAKE OF ANY APPLIANCE.
G) MIN. 2-FT CLEARANCE BELOW EAVES OR OVERHANG.
H) MIN. 1-FT CLEARANCE HORIZONTALLY FROM COMBUSTIBLE WALL.
I) MUST BE A MINIMUM OF 36-INCHES ABOVE THE ROOF AND 24-INCHES ABOVE THE
HIGHEST POINT OF THE ROOF WITHIN 10-FEL;'I,.
/ �~
/ Y
�
i `
/
�
�� �.---! ---� h
--� _� £�� ----�- _____�-
_ Ff a FI
r (
�J J f.� � i
_1 Q
� � J.- � A
E` +
Notes on termination of Yellet Vent Yipe from NFPA 211 (2006 ed.) SeCtion 10.4 Termination: 10.4.5
(See also"FLUE SYSTEM"section of manual AND additional notes above):
- Not less than three (3) feet above any forced air inlet located within ten (10) feet.
- Not less than four (4) feet below, four (4) feet horizontally from, or one (1) foot above any door,
window or gravity air inlet into any building.
- Not less than two (2) feet from an adjacent building, and not less than seven (7) feet above grade
where located adjacent to public walkways.
The exhaust exit shall be arranged so that the flue gases are not directed so that it will affect people, overheat
combustible structures, or enter buildings. Forced draft systems and all parts of induced draft systems under
positive pressure during operation shall be installed gastight or to prevent leakage of combustion products into
a building. Through-the-wail vents shall not terminate over public walkways, or where condensate or vapor
could create hazards or a nuisance. �
8e sure to follow local codes and all manufacturer's instructions (including exhaust pipe).
Consult a professional installer and/or call Technical Support if you have any questions.
9
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS,INCLUDING
CLEANING THE UNIT AS SPECIFIED,AND RENLACING GASKETS ANNUALLY,AND PARTS AS NEEDED.
ENGLAND'S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR WJURY WCURRED DUE TO NEGLECT,OR
DUE TO UNSAFE WSTALLATION OR USAGE OP THIS PRODUCT.CALL TECHNICAL SUPPORT WITH ANY QUESTIONS.
, ._ . . ,.,,...
____.�
��� :�:�:��..�. ,
. .:����.: _�::.> .�_:�.:�
�
Freestanding Pellet Installation ���`_M?�G.My�
Caution: Follow the pipe manufacturer's installation instructions and directions for
passing through combustible walls and ceilings. Check local codes in your area.
Illustration 1
' � r� ��
�
� � = —�..�
�� � � �
'�--� � � � --- � —_
—� Our Part AG3000 is
acceptable for
Must have minimum through-the-�vall
3"adapter before tee � � � installation.
for lon�er run. (AC-3100 for 4000+
For shorter run � � � ft.installations.)
(such as Masonry n � � ��
Connection below), —� � �
tee alone is . ___--- •-- ,-
acceptable. ,5-m�. Basement Installation should
� be peri�ormed by
�3'_c�earance proCessional installer. Use
`_
� �,���t ' 3" metal i e and cou ler
Inelalla��/ P P p
for Outside Combustion Air.
� �i Minimun�3 feet (3')
_ clearance fi•om ground to the
� ` 3"Outs de ���� pellet Vent Exhaust Pipe.
/ � ir ipe ��
O�side A[R fS M�1CNtY � :� ��=-
�
��������y � ``" \� Masonry Connection
F--1
� � �.'1 ` _I•�� ' �
_.)
�u x�„�'_�x,��...r� I
. __ r_n
• r y I
'�-, �_�/ _ �
�_` _� l�-- �' �;
-- __,�-� _ .
1.lf 3°tlue pipe exceeds 15' in length,increase to 4"flue pipe for remaining flue connections.
2.Total flue length should not exceed 35'.
3. Horizontal run not to exceed 4'.
4.Floor protector must extend 6"fi•om fi•ont of unit,4" from sides and 1"from rear.
5.If the total i�n of outside air connection exceeds 6',if more than 2 elbows are used,or if a
basement install,use 3"metal pipe(and coupler)instead.
6.Or�tside Air is mandatory.for proper safe operatior:.
FLOOR AND WALL PROTECTION
Floor Protection
If your floor is constructed of a non-combustible material such as brick or concrete, there is no need
for floor protection. If the floor is constructed of a combustible material such as hardwood, linoleum, or
carpet, then you will be required to use floor protection between the unit and the combustible. The
protection should be U.L. approved or equivalent and must be large enough to provide a minimum of one
inch (1.0") behind, four inches (4.0") on both sides of the stove and at least six inches (6.0") in the front of
the unit. This floor protection is intended as spark and ember protection only, therefore it need only be
noncombustible there is no re uired R value .
INSTALL VENT AT CLEARANCES SPECIFIEU I3Y'I�HE VEN"C MANUFACTURER.
Wall Protection
From the rear and the sides of this stove only six inches (6") of clearance is required to paneling, wallpaper
or drywall. The pellet vent pipe usually requires the standard three inches (3") of clearance, or as
recommended by the manufacturer. Normally additional wall protection is not required with this type unit.
8
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAWTENANCE INSTRUCTIONS,INCLUD[NG
CLEANING THE UNIT AS SPECIFIED,AND REPLAC[NG GASKETS ANNUALLY,AND PARTS AS NEEDED.
ENGLAND'S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRF.n ni iF Tn tvFr,r FrT nR
.
The through-the-wall installation is the least expensive and simplest installation. In a
through-the-wall installation you should be mindful of the snowdrift line, as well as dead
grass and leaves. We recommend a three foot (3') minimum vertical rise on the inside or the
outside of the dwellinq.
Through the Ceiling .
When venting the stove through the ceiling, the pipe is connected the same as through the wall,
except the clean out tee is always on the inside of the house, and a 3" adapter is added before the
clean-out tee. You must use the proper ceiling support flanges and roof flashing supplied by the pipe
manufacturer -- follow the pipe manufacturer's directions and Illustration 1 in this manual It is
important to note that if your vertical runs of pipe are more than fifteen feet (15'), the pellet vent pipe
should be increased to four inches (4") in diameter. Do not exceed four feet (4') of pipe on a
horizontal run, and do attempt to use the least number of elbows in the flue system. If an offset is
used it is better to install a 45-degree elbow whenever possible. NOTE: Installing elbows may inhibit
your draft by up to 15%per elbow.
Existing Flue System
If you are replacing a wood stove with a pellet unit the chimney or pipe should be thoroughly
cleaned before proceeding with the installation. The flue system should be either masonry or a UL
approved pre-manufactured Class A flue system. The flue thimble should be either six inches (6") or
eight inches (8") and the proper reducer (6" to 3" or 8" to 3") can be purchased at your local dealer.
Connect a three inch (3") tee with clean-out to the pipe adapter -- seal this with high temperature
stove cement, then extend your pipe to the installed reducer at the thimble. If the thimble is in the
ceiling, the pipe will go straight up, but if the thimble is in the wall another 90-degree elbow will be
required to make the connection.
Outside Air (Outside Combustion Air Intake)
Outside air is mandatory for this unit to operate properly. This unit has been designed and tested
with this connection, because so many homes are airtight and there is not adequate combustion air
available inside the dwelling. The air intake pipe is located on the bottom side of the burn pot (from
the rear) and measures 1 'h" inside diameter (I.D.). The connection can be made with a metal 1 '/8 "
I.D. coupler and pipe (see "Important Information" section of manual), and should exit through the
wall. Be sure to secure the pipe to the unit with a clamp or aluminum tape. The outside end of the
pipe should be covered (screened) to prevent foreign matter from entering the system. Our Outside
Air Kit (Part Number PU-OAK) can be used. If the unit is located below ground level, you will need to
run the pipe up and then outside the dwelling. NOTE: If the total run of the connection exceeds 6', if
more than 2 elbows are used, or if a basement installation, use 3" metal pipe (and coupler) instead.
Note: If an older unit, measure the opening to determine what size pipe to use or couple to.
Mobile Home Installation �
Secure the heater to the floor using the two holes in the pedestal. If the unit is on a combustible
surface, you will need to drill matching holes in the floor protection that you choose (see Floor
Protection section). Do not disturb the structural integrity of the home, be sure the unit is
permanently electrically grounded to the chassis of your home and remember that outside
combustion air is mandatory.
WARNING: DO NOT INSTALL IN SLEEPING ROOM
CAUTION: THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR,WALL AND
CEILING/ROOF MUST BE MAINTAINED.
IMPROPER INSTALLATION: The manufacturer will not be held responsible for damage caused by the
malfunction of a stove due to improper venting or installation.
Call 800-245-6489 and/or consult a professional installer if you have any questions.
IMPORTANT: Improper hook-up (too much pipe, too many elbows, etc.) will cause the unit not to operate.
Call Technical Support (800-245-6489) if you have questions about your hook-up or if your unit will not
operate.
7
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS,INCLUDING
CLEANING THE UNIT AS SPECTFIED,AND REPLACING GASKETS ANNUALLY,AND PARTS AS NEEDED.
ENGLAND'S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR WJURY INCURRED DUE TO NEGLECT,OR
DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT.CALL TECHNICAL SUPPORT WITH ANY QUESTIONS.
�.�.
_ _ ___�.._ -.....__ ��
_� __. _ ..
MPORTANT NOTICE: This unit must be properly installed to prevont th� pq�,slbility
of a house fire or "smoke-back." The instructions must be strictly adhor�d tcr.
Do not use makeshift methods or material which may compromise the Inst�ll�tlon.
Your unit requires periodic maintenance and cleaning (refer to manual). Fsilure to �
maintain your unit may lead to a variety of problems, including but not Ilmitod to
smoke spillage into the home. England's will not be liable for consequentlal or
in� direct damages to property or persons resulting from the use of this product.
� FLUE SYSTEM � µ� � �
Caution: Follow the pipe manufacturer's installation instructions and directions for pessing
through combustible walls and ceilings. Be sure to check loca/codes in your aree.
NOTE: See the installation drawing later in this manual (Illustration 1).
This unit is equipped with a negative draft system that pulls combustion air through the burn pot
and pushes the exhaust air out of the dwelling. If this unit is connected to the flue system other than
the way explained in this manual, it will not function properly.
For any of these installations, keep in mind that each elbow used reduces draft by 15%;it is good
practice to add 3' (three feet) of vertical rise for each elbow used. Example: Atter the 2"d elbow
used, have 6'(srx feet) of vertical rise before terminating your vent pipe.
Pellet Vent Pipe
The UL approved pellet vent pipe that we recommend is a twist lock system; however, it is still
recommended that high temperature silicone (AC-RTV3) be used at each joint. England's Stove
Works recommends the use of Dura-VentO twist-lock pipe (AC-3000 kit) (if you use other pipe,
consult your local building codes and/or building inspectors, and secure each joint with at least three
screws—see Important Information, above). Do not use "B" vent gas pipe or galvanized pipe with
this unit. The pellet pipe is designed to disassemble for cleaning and should be checked several
times during the burning season — pellet vent pipe is not furnished with the unit and must be
purchased separately. For installations over 4000 ft. above sea level the exhaust should be vented
with 4"pellet vent pipe (AC-3100 kit). Do not install a flue damper of any kind in this system,
and do not connect this unit to a flue system serving another heating appliance.
Through the Wall
To vent the unit through the wall, connect the pipe adapter to the exhaust motor adapter. If the
exhaust adapter is at least eighteen inches (18") above ground level, a straight section of pellet pipe
can be used to initially pass through the wall (see Illustration 1). Your dealer or our factory should
be able to provide you with a kit that will handle most of this installation, which will include a wall
thimble that will allow the proper clearances through a combustible wall. Once outside the structure,
a three-inch (3") clearance should be maintained to the outside wall and a clean out tee should be
placed on the pipe that extends through the wall. We recommend a minimum of three feet (3') of
vertical pipe with a 90-degree turn away from the house. At this point, a one-foot (1') section and
horizontal cap will complete the installation (see Illustration 1).
A wall strap should be placed just below the last 90-degree section to make the system more
stable. If you live in an area that has heavy snowfall, it is recommended the installation be taller than
three feet (3') to get above the snowdrift line.
The same type installation can be used if your stove is below ground level by adding the clean-out
section and vertical pipe inside until ground level is reached. However, we recommend basement
installation be performed only by a professional installer. For basement installations, a 3" (three
inch) pipe and coupler must be used for Outside Combustion Air, and a minimum clearance of 3'
three feet must be maintained outside the dwellin from the round to the Pellet Vent Exhaust Pi e.
Call(800)516-3636 to inquire about the AC-3000 Through-the-Wall Kit or the AC-3100 High Altitude Kit.
6
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE WSTRUCTIONS,INCLUDING
CLEANING THE UNIT AS SPECIFIED,AND REPLACING GASKETS ANNUALLY,AND PARTS AS NEEDED.
ENGLAND'S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY IIVCURRED DUF'_TO NEGLECT,OR
DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT.CALL TECHNICAL SUPPORT W(T(1 ANY QUESTIONS.