Loading...
20130144 Permit Pkg 03202013 o� � City of Yelm Permit ►vo.: 20130144 � Community Development Department Issue Date: 3/20/2073 � (Work must be completed within 180 days) Building Division Phone: (360)458-8407 w� h«�c=o� FBx: (360)458-3144 Applicant: Name: FREESTONE Phone: 253-896-1300 Address: 6820 20TH ST E STE A FIFE WA 98424 Property Information: Site Address: 15345 CALLIE AVE SE 140 Owner: FREESTONE INC Assessor Parcel No.: 41610014000 Subdivision: CHERRY MEADOWS Lot: 140 Contractor Information: Name: FREESTONE Phone: 253-896-1300 Address: RICK CARLILE 6820 20TH ST E STE A FIFE WA 98424 Contractor License No.: FREESI*969NZ Expires: Project Information: Project: NEW RESIDENTIAL BUILDING Description of Work: LOT 140, PLAN 3115B Sq. Ft. per floor: First 1318 Heat Type(E►ectric, Gas, Other): GAS Second 1796 Third Garage 555 Basement Fees: Item Contractor Fees NEW RESIDENTIAL BUILDING FREESTONE $17,190.36 MECHANICAL KLIEMANN BROS. $ 78.25 PLUMBING PELTRAM PLUMBING $ 118.00 TOTAL FEES: $17,386.61 Applicant's Affidavit: OFFICIAL USE ONLY I certify that I have read and examined the information contained within the application and know the same to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of #Sets of Prints: Yelm regulations including those governing zoning and land subdivision,and in addition,all covenants, easements restrictions of record. If applying as a contractor, I further certify that I am currently Final Inspection: registered n t State of hi ton. '� �111 � Date: Signature Date <7� Firm By' Git� of Y�lm (36 } 458-8402 REC#: 00122984 3/20/2U13 8:57 AM OPER: CO TERM: 001 REF#: 1972 TRAN: 33.0000 BUILUING PERMITS 20130143 17,386.61CR FREESTONE 15331 92N0 AVE SE i09 BLU-RES1 17,190.36CR MECH 78,25CR PL 118.00CR TRAN: 33.0000 BUILDING PERMITS 2Q130144 17,386.61CR FREESTQNE 15345 CALLIE AVE Sk 140 BLD-RES1 17,190.36CR MEGH 78,25CR PL 118,OOCR TRAN: 33.U000 BUILDING PERMITS 20130145 16,766.36CR FRE�STONE 15417 91ST AVE SE 168 BLD-RES1 16,570.11�R MECH 78,25CR PL 118.00CR TRkN: 33.0000 BUILDING PERMITS 20130140 17,38f,.61CR FREESTONE 15323 KAYLA ST SE 56 BLD-RES1 17,190.36CR MECH 7�.25CR PL 118.00CR TRAN: 33.00U0 BUILDING PERMITS 20130141 17,328.09CR FREESTQNE 15317 KAYLA ST 5E 57 BLq-RES1 17,110.84CR MECH 78.25CR PL 139.OQCR TRAN: 33.UU0� BUILDING PERMITS 20130138 16,�102.74CR FREESTONE 15431 KAYLA ST SE 46 BLD-RES1 1b,506.49CR MECH 78.25CR PL 118,OOCR TENDERED: 1U2,957.02 CHECK APPLIED: 102,957.02- CHANGE: ^� 0,00 YELM COMMUNITY SCHiIOLS PO BOX 476 YELM WA 98597 C;lerk; Croy Terminal : ? Recei pt: 203102 Manual R�ceipt: NFRtESTONE NFREESTONE FREESTONE, LLC 6820 20TH ST E SUITE A FIFE, WA 98424 3J2u/2013 8;45 AM Q� Item _____� Price 1 CPF MITIGATION 3015.00 MITIGATION 03-021/LOT 46/15431 KAYLA ST SE;YELM 1 CPF MITIGATION 3015.00 MITIGATION 03-021/LOT 56/15323 KAYLA ST SE;YELM 1 CPF MITIGATICN 3015.00 MITIGATION 03-021/LOT 57/15371 KAYLA ST SE;YELM 1 CPF MITIGATION 3015.00 MITIGATION 03-021/LOT 109/15331 92N� AVE SE;YELM 1 CPF MITIGATIQN 3015.00 MITIGATION 03-021/LOT 140/15:�45 CALLIE AUE SE;YELM 1 CPF MITIGATION 3015.00 MITIGATION 03-021/LOT 168/15417 91ST AVE SE;YELM Subtotal : 18090.00 Tax: 0.00 Total : 18090.00 Check 18090.00 1973 Change Due: 0.00 THANK YOU ���0 � � �1 CITY OF YELM RESIDENTIAL BUILDING PERMIT APPLICATION FORM � Project Address:�� �7'"'Oc`7 G �S c.J�Parcel#: `C���On(�D O O i Subdivision: �ot#: � Plan#: �� Zoning: �Q New Construction ❑ Re-Model/Re-Roof/Addition ❑ Home Occupation Sign ❑ Plumbing ❑ Mechanical ❑ Mobile/Manufactured Hom lacement ❑ Other Project Description/Scope of Work: t ` Q Project Value: � 5 ,°� Buiiding Area(sq. ft) 1 g`Floor ���� 2"d Floor ��W Garage �� p�p� Basement Carport � �o�� #Bedrooms #Bathrooms�� _'d�-- Heating G�, /OTHER or ELECTRIC (Circle One) Are there any environmentally sensitive areas located on the parcel? �_ /fyes, a completed environmental checklist must accompany permit application. au��Q�NC�.oww���NaM�: ADDRE S O EMAII ' ���yy� C�N � STATE ZIP TELEPHONE �q(o-�3fjp ARC�1�T��"�`l��I�tIVE�F� LICENSE# ADDRESS �S _ EMAIL��hq C '�q,.,, � CITY gp�.h2� STATE ZIP 1 TELEPHONE � GEN�RAC,CQIV'FR;qC'F'pf� TELEPHONE 5 � ADDRESS EMAIL � � CITY STATE IP FAX C��� gq�-d(o 6p CONTRACTOR'S LICENSE# E 2 EXP DATE CITY LICENSE# �vt4 PLUMBIN(�C��ITRA�TQ e LEPHONE 1- ADDR SS EMAIL CITY STAT ZP 0 t FAX (aS�, 91-9� CONTRACTOR'S LICENSE# t7C�Qs0'TS EXP DATE�ICENSE# � ao MECNANtCa�CONTRa�TOt� � ►c TELEPHONE a6 5 -O ADDRESS �}'103 III�'� 51- ' EMAIL CITY IQ.Q.pry�q„ STATE ZIP L F,q)( ( CONTRACTOR'S LICENSE#kITEII�IP�{�OZI BT EXP DATE� CITY UCENSE# � 'a.'1 201� Copy of mitigation agreement with Yelm Commurnty Schools, if appiicable. 1 hereby certlfy that the above Information Is correct and that the constructlon on,and the occupa�cy and the use of the abov cribed property wlil ba In accordanca with the laws,rules and regulatlons of the Stab ot Waahington and tha CI of Y m. o� � App ica s Signatur Date Owner/Contractor/Owner's Agent/ ontractor's Agent(Please circle one.j All permits are non-transferable and wili expire If work authorized by such permlt is not begun withtn 180 days of issuance, o�if work is suspended or abandoned for a perio REC �VED � MAR O 1 2013 � 105 Yelm Auenue Weat (36 - 383s l� Yelm, WA 98597 (360 458-3144 FAX � wraw.ct.yelm.wa.ua � �,� �� .���_ � ���-�� r-���- -- y �y--s�-�-s- 52.00 l0 l0 in 939 1�� �"ja GY � �DF2YWEL `� N ! � .Y. .___ ___. � N t 18 x 12 I ROOF' � � GQV PATIO � i� I DRAfNS � � �` SCALE.���-2at _ , 39' i � ��.. � �� �� BREV ! �� F ' �,,, �,,, � � D1AG 63.41' I � Q N 1 � °° � � 6.� 39' �.S' ° o v� � zn ���~'� -���� � � i �/ /'3 � _., � � 2 CAR j� �, �t__ �_ .._...�.._..,._..,..�. � GARAGE 1 ° �.. � ;� �}_ ,��)� �.l ..V_::.,. . _ ___ .v�.. j o r w G �t ' 22' COV.PoRCH � �_ 1 - - - - — _ �, ° � _ CoNG, �K U� � � o � � SLCE UE �p INDICAT�S 1'x 10'ADDI7tOtVAL =° 15' r'? M UTiLITY�ASEMENT LYtNG 5'ON � � HAMMER � E17HER S1DE OF TH�CQMMON l.QT � / HEAR ��� � S � �0 vr,�r �c>,1 ! �0, \�}-fis f�,s, 39.50 � CaNc �T � f— ,. --- ' __ ._. ._. �4 A<9NTF�<� 2� `�iS� �'r Step Tank Excavation In Violation Of ,. � � � c�R6 s ! b,`O' j The Required 5' Minimum Set Back To \\\��F S �'•�,� �f ( ° Foundation Shall Be Back Filled With �' Q4�p l I CDF. �'�,� w � � Front Porch Foundation And Step Tank � Location Shall Be Staked For Set Back , ; C��� �� � Inspection. � _ _ /�.• - - - ' _. '�-� _ _ , �4�ti - - ._ � � _ _, , �_ _- L�, , C{7NNECT 4" PVC R�OF `�'�� �� ' .� DRAiNS T4 ORYWELL �s �.��.��T�.� NO 5' EAVE '� _ �, ENCROACNM�NT THIS LOT �oT � 40 - �� _. . ����A ows -__....._. �'ARGEL #: 4`!��40 144 00 ��"�'��� �reeston� Gherr�a Meadows �.LG l.ot 51ze: pro�eGt f�ddrey5: 6820 2Pth �t. � 5ulte A Flfe, WA q8424 6,463 Sq. Ft, 15345 CALLIE AVENUE SE ����8q6-i�oo � Prescriptive Energy Code Compiiance for Single Family and Duplex Housing: Zone 1 • Project Information Contact/nformation Pian 3115 Freestone Inc, Fife WA:98424 253'896-1300 Yelm �������� Rick Carlile�Gell 253�381��Q80�����. ��� � This set of forms has been developed to assist permit applicants documenting compliance with the Washington State Energy Code, (2009 edition). This set is for structures built under the IRC and located in Climate Zone 1. The following forms provide much of the required documentation for plan review. The details noted here must also be sMown on the drawings (WSEC 104.2). This form is not a substitute for the energy code itself. To obtain a copy of the energy code, go to the following web address. http://www.energy.wsu.edu/code Glazing �z a a 6 �o Glazing U-Factor poor 9 2 Vaulted Wall Wall• int Wall• ext 5 Slab Option Area : Ceiling 3 Above Be(ow Below Floor on %ofFloor Vertical Overhead�� U-Factor Ceiling Grade Grade Grade Grade R-49 or R-21 R-21 R-10 OO I 13% 0.34 0.50 0.20 R-38 R-38 jnt.� TB R-10 R-30 2, Adv. R-49 or R-21 R-21 R-10 O II 25% 032 0.50 0.20 R-38 R-38 Int.' Tg R-1D R-30 2, Adv. R-49 or R-21 R-21 R-IO O III Unlimited 0.30 0.50 0.20 R-38 R-38 Int.� TB R-10 R-30 2, Adv. See WSEC tab/e 6-f forfootnotes Glazing Schedule Attached to Document � Does not apply. �SEE INSTRUCTIONS) Using Prescriptive Option III.All glazing and doors meet maximum U-factor.Alternate heating size method submitted. O Option 1 or II,Glazing to floor area limit (WSEC 602.7.2) ❑ Area weighted window,skylight or door U-factor(WSEC 602.7.2) ❑ As part of the heating system sizing cakulation (IRC M1401.3&WSEC 503.2.2) Radiant slab: ❑ R-10 foam insulation, continuous with thermal break (WSEC 502.1.4.9) Chapter 9 Options Total of 1 Credit Reauired Opt. Opt. Description 1a Hi h Efficienc HVAC Equi ment 1 1.0 � 1b Hi h Efficienc HVAC Equipment 2 1c Hi h Efficienc HVAC Equi ment 3 2 Hi h Efficienc HVAC Distribution S stem 3a Efficient Buildin Envelo e 1 3b Efficient Buildin Envelope 2 3c Super-Efficient Buildin Envelo e 3 4a Air Leaka e Control and E�cient Ventilation 4b Additional Air Leaka e Control and Efficient Ventilation 5a Efficient Water Heatin 5b Hi h Effiecienc Water Heatin R����v�� 6 small Dwellin unit MAR 01 2013 7 Lar e Dwellin Unit 8 Renewable Electrie Ener *1200 kwh Total Credits � 1.00 WSEC Prescriptive Worksheet(2010 edition)Zone 1 WSUEEPIO-010 Copyright 2010 Glazing Schedule Project/nformation Contact/nformation Plan 3115 Freestone Inc, Fife WA 98424 253 896-1300 Yelm Rick Carlile Cell 253-381-6080 Conditioned Floor Area ' 3115 Sum of UA for Heating System Sizing 125.5 Sum of All Glazing Areas From Below 362 Glazing to Floor Area Ratio 11.61% 602.7.2 Exception Ratio(not to exceed 1%)� Exterior poors Plan Component Door Percent Width Neight Glazing Door poor ID Descri tion Ref. U-factor Glazed Qt. Feet �"�' Feet �"0n Area Area UA Frnt Fibe� lass�insutat�d, � ��;�� IECC� Q�;160�, ��: ��' 1 �'� 3 �:` �. , 6. .;,� 20�.0 3.2 GBF.':��One Exempf Swinging Door<24 Square Feet _ �� 1 ; 2 �- F �� � 17.8 Sum of Glazing Area, Door Area, and UA (do not include exempt door) 20.0 3.2 Area Weighted U= UA/Area 0.16 Sum of Area and UA for Heafing system size onty(include exempt door) 37.8 3.2 Vertical Glazing (Windows,Glazed doors using Exception 602.6#1) Pfan Component Glazing Width Height Glazing ID Descri tion Ref. U-factor Qt. Feet '"�'' Feet '"`h Area UA L&Q 2 Gfz Vin ��-l�a�vt�E� >= NFRG 0.34f1 ` 2' 5� . °F, a ' : 50.0 17.00 Kit° : 2 GIz Vin (Lov���;, °..; NE'RC Q;3'4f� 1 �°" . ; 5. : 30.0 10.20 Gr R 2.Glz Vin k�ouu E Su er S acer SGQ <;.! NFRC t?,33Q 1 6 ; _� 8 48.0 15.84 Gr Ft 2 Gta Vin t�l:ovu�:;:: ,� �� � � � ����� IVFRC� ��,34D' ��� 2 � 4°� �' S.� �� � � � 40.0 � 13.60 GrR 2 G{��/in [.Low�RW -��:F . ���� � :"° NFR� �.32t��� .� 2 .�. 2:��;� ���. �s.�,�� �.'��� ���� � 12.0 � �3.84 Br3« 2 GI�Vir� �L��t�.����; -�, �� �: � =� � �IVFI�G Q:34tk",-:� 1� �:`:,'� _ �,..�� , � � 25A � 8.50 Br� 2 GIz�Vin�t�':ou��,.��x � t � '� ; = N�R� �t�.�4�� ' 4 ��.�z �rf` 4 �� � 80A � 27.20 Mbr` �GI�Vi��C��:c�w,�'�t�! .� .., ����� . , .,.= N�f�G f�:34t3r�`.����� � � .. ���'�; ,:w. � . ,��;� � � � 24.a�� 8.16 Mbr 2 GI�'Vin I���v��.° �,���,�. ,, =� t r N�R� t�3qQ�. � 4°����. 2 ;;, ��� � � � � 4A �� 1.36 Loft 2 GIz Viii I Law�;=; �. � � 4 � NFRC (�.34�` ` 2, 4�;' �, � 40.0 13.60 Ent�� 2.Glz���/(n ,FLovV E�;�.�� '�`, . ��.� v . �'.'� NFRC �:34q. ,�� � 1; � ,� 2�•.� ," � H�� �'�: 8.8� 2.98 ,��� � , �. .�. � ��.,; , . , � . , ;. - :,�. �� � ����� . t`� ,�< .:" �; ;. � ;,. ° Sum ofArea and UA 361.8 122.28 Area Weighted U=UA/Area 0.34 WSEC Prescriptive Worksheet(2010 Edition) WSUEEPIO-010 Copyright 2010 Overhead Glazing Pian Component Glazing Width Height I D Descri tion Ref. U Qt. Feet �"`�' Feet �"�' Area UA Sum of Area and UA Area Weighted U= UA/Area Doube Glazed Garden Windows Section 602.7.2 Exception Plan Component Width Height ID Descri tion Qt. Feet Inch Feet �"�' Area UA Sum of Area Sum of Area X 3(This total is automafically included in the glazing area total.) Glazing UA for Heating System Size Only=Area X 0.63 WSEC Prescriptive Worksheet(2010 Edition) WSUEEPIO-010 Copyright 2010 Simple Heating System Size: Climate Zone 1 Project lnformation Contact Information Plan 3115 Freestone Inc 253 896-1300 Yeim Rick Cariile Cell 253-381-6080 Indoor Design Temperature 70 Outdoor Design Temperature 17 Design Temperature Difference (aT) �T=Indoor-Outdoor Design Temp 53 Conditioned Fioor Area 3115 Conditioned Volume 26230 Glazing Copy Sum of UA from Glazing Schedule 125 Attic U-Factor X Area = UA R-49 0.027 1798 48.5 R-38 Advanced 0.026 Single Rafter or Joist Vaulted Ceilings U-Factor X Area = UA R-38 Vented 0.027 � � Above Grade Walls U-Factor X Area = UA R-21 0.056 2576 144.3 � Floors U-Factor X Area = UA R-30 0.029 1780 51.6 Below Grade Walls U-Factor X Area = UA 2' Depth Walls D.04Z 3.5' Depth Walls 0.041 7r' De tp h Wails � 0.0371 Slab Below Grade F-Factor X Len th = UA 2' Depth 0.59 3.5' Depth 0.64 7' De th 0.57 �--� Slab on Grade F-Factor X Len th = UA R-10 2' perimeter 0.54 R-10 Full- Heated 0.55 Sum of UA 370 Envelope Heat Load 19605 Btu/Hour Sum of UA X OT Air Leakage Heat Load 15014 Btu/Hour ((Volume X 0.6j X On X.018)) Building Design HeatLoad 34619 Btu/Hour Air Leakage+Envelope Heat Loss Building and Duct Heat Load �� 34619 Btu/Hour If ducts are located in unconditioned space:Sum of Building Heat Loss X 1.15 If ducts are located in conditioned space:Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 150% 51928 Btu/Hour Building and Duct Heat Loss X 1.5o WSEC Prescriptive Worksheet(2010 Edition) WSUEEPIO-010 Copyright 2010 U � � � � . , � � � � c �1 Q. y � (� � �' � � �V �O � � � V N � � � � S� � N +�+ V 0 >+ � � � � � � � � +.' -� � q0 Z � � � � � � o a � �� 0� � � � '� "� cm � � � �3 0 U a� � � 0 � � � � Oti � •,� cn p) �, a� o � a S� c p f� .� �1.� 0� � .N � � a� � c � � ca q �. - � � � o � � � +� N � � f0 � •� � � Q � � � � .� w � � � c� � � � � w � � � '� �u w � ca �,� > � .,� Q = w � .Q-� ca U U N .� � E � � W JI— � N 0� � o U w ao � O (�,� =J � � � rn Z � o ^�1 J +r � _ � o o � �- � V � � o � � m .�� ca "' w � N ° � „ �' � � O M W Q M r � � w � � O Z U � L.L � CO LL N ` g/� .� L Ly, N � � � � � � tn Z � � . . � � � O � O N t� � ;«� (C e � J U � �U � N � � L � � � � � ii 4 = � � � � �. O � .: �� Q c� v a N N V O N a' Z Q rn �c 5 — rn ' � c � � c� c o� � � � � � � �� � °��ra '� � 3 'S a� � a '� m � cn m I�� m O O Q � ;s-�- �c �_., .� � � � �������� , �:'�;a :i C'� J�1 �-I � � a� � � �. � � � � � � 1�T4RTH �ITEST ��.������ In�ulatYOn Ce�t7ficat�/Blo�ver T)oor Test FForm . Batts&Blankets ThermaI Performance(Attic AppIication) _When installed in accordaace tivith the manufacturer's The sfated th,ermal resistance�-value)is�rovided bY installin�in accordance wifh the manufacturer's recommendafions,Knauf Batts&blankets wiI1 provide instructions,fhe required number of bags per 1,00�sq.ft.of net area,af not Iess than the Iabeled minimum the full R-vahie. thicicness.Failure to insfall.both the required number of bags&a�least the minimum thicicness will resulf in lowe��insulation R-va1_ue. P�•Valir2 I�linimom Thicknzs� R-Valu� Baes/I,000 sq.fi. bia�im�nn Covera�z t�4inimum lVei�ht I�ti�iim<<m Thiclaizss To obtain an Instatted insulation To obtain zn The number of Contents of tlus bag The VJeigfit/5F of Iastalled insulation "� insulaHon resistance shou[d not be less insulation bags11,000 SF of ne should not cover more instal(ed insu[ation should not be less ?; R-Value of: than; resistance area should not he flian; s[�ould not 6e less than: titan: i'� -Value}of _r:-3�7iD 10.25" R-o0 29.'I �3.GSI' .9521bs. 79.'/50" -- -- -- - -- -- _ _ _ - -- F-:�8 � 12.OD" R-49 � 23.5 a2 s��F� I .7531bs. ���__�,5' - R-30 HD 8.25" R-44 � 20.9 47.8 SF .6701bs. 14.875" R-30 lO.OD" R-38 17.8 56.2 SF .569Ibs 13.000" R26 9.00" R-30 13.6 73.3 SF .4371bs 10.375" R-22 6.50" R-26 11.8 85.0 SF 3771bs � 9.125„ R-21 FID 5,50" R-22 9.8 102.2 SF .313 lbs 7.750" R-19 6.25"'�'r R-19 8.4 1193 SR .268 Ibs 6.750" R-15�ID � 3.50" R-13 5.7 175.3 SF .183 lbs 4.750" R-13 3.50" R-11 4.7 210.8 SF .1521bs 4.000" R-11 3.50" Bag Weight-Nomina1301bs,Minimum 291bs.This prodtict conforms fo the performauce requirements of ASTM C 764, R-8 2,50" Type 1,&cancelled Federal Specification HH-1-1030B,Type 1,Blass B.R-Values are determined in accordance wiih '"R-18 in a 5.5"cavity.Conforms to ASTM C 687&C 518."R"means resisiance to heat flow.The higher fhe R-value,fhe greafer the insulation power.To get the C665&Federal Specification HH-1-521F inarked R value,it is essential that the insulafion be installed properly.If you do it yourself,get insfructions&follow them. To achieve 1abeled R-value,this product musf be applied with a pneumatic blowing machine&a corrugated hose tivith a minimum.25"intemal corrugation,a minimum length oi 150$.&a diameter of at least 3".Coils in fhe hose should not be less than 36"in diameter.Acceptable material feed rate is 5-35 Ibs./minute.Recommended feed rate is � 15-25 Ibs./minutes. : Bnilders Insulation 5fatemen�, Batts and/or blanlceis liave been mstailed m conformance�vith the above 2009�a'��C 3be,sidenfial Ener�v Compliance Cerfiricafe-33Lile�in�!�ir Lealra�a recommendationsfo rovideathermalresistanceof.,.. . ,'��.e:.�s�c'��� � �12'V2lue' 3tau'd�d� E"dut�&Test CoFtd'[tion: :CoIDioeilts: Attic Area R __- R-49 Dafe: '�• (• � Ext.Walls R- R-2I Time �(p Inter.Walls R- R-11 Indoor Temp: Sprinkler Tenting R- 12-8 Outdoor Temp: Knee Walls R- R-21KF Floor Area(sq ft) 3 ( Completed as oi: �` ��'�3 Buildin�Air Lea4ra��Tar�et: ��,A I,ess'I'han O.00D30 Installers Name Print: 'T'est#1-Depress � Press Pxetest Baseline Pressure (Pa) Insfallers Name Sign: ",$ •1'FC°s's.; a F�o�i -s�"�'{:'s�+`".Piess;' a K` °F1oiV ��; Site Address: �534s CauaE Av�. S�. , f _ - �Fr� a8597 PosiTestPressure: FanModel/SN: i��(.f�D �3 Resulfs:SLA(SpecificLeakageArea):.���z� ��+1� ' 4. �-[ � Home Builders Signahire: 7['esf r 2-Depress Press Pretesf Baseline Pressure (Pa) �iome Buiiders Address: �zB 'Pios. � tQ�v `�:�2 t 2�izPtess�� � &t�t� Insulation Contractor: Insulafion Northwest LLC Post Test Presstue: Fan ModeUSN: P.253-846-0121 P.O.Box 732069 Resulfs:SLA(Specific Leakage Area): ' F.253-846-8096 PuvalIun,WA.98373 �davit: I certify tliat this Specific Leakage Area zs accurate&defennined using Blower poor Test Sfandard 502.4.5 Building Air Leakage Testing. Ter.hnir,ian Name Prinf: ���_ Teclmician Name Sien: /� ,/ '��y`O�i�--- Jul. 24. 2013 10: 22AM Kl iemann Bros HVAC No. 1971��-P, 2 � r � `"� � � �"�.�.Qc���-�--5�yo� �� , s , . , � ..� ', `�, � i" �+, �,� ;�, i �� . �. 0 �� Duct Leakage Afflda�it (New Construction) . permit#; � �..� �% � 4 House address or fot number; �� � �/ �/�'� �� CiIY: �C/rr� � zlp: ��G17 Cond.�Ioor Area{ft2):���� Source(clr�le one): atl �stimated Measured ❑ Duct tlghtness testlhg(s not regulred.7he tota11e2kage test is not requlred for ducts and sir handlers located entirely wifhln the building thermal envelopa.�uats locatsd In crawl spaces do not qualify for thls exception. Alr Handler In conditioned space?[_]yes�fio Alr Handler pressnt during test?�ies❑ no Circle Test Method: Leakage to Oufslde Total l,eakage Maximum ducf leakage: Post Construction,total duct leakage: (floor area x.04)� C�MQ25 Pa Posf Construction,leakage to oufdoors: (floor area x.04)= C�M@25 P� ' Rough-!n,total duct leakage wlth air handler Installed: (floor area x.Q4)_ ���7 CFM@2�Pa Rougfi-!n,total duct leakags wlth air handler not insgallad: (floor area x.03)� CFM@251�a Tast Result:� ( `� CFM@25Pa Ring(circle one ff applicabfe}: Open 1 � 3 Duct Tester Location:_ �� Pressure Tap Location:, �'^���� 5,���� 1 cerEif�r that these duct leakage rates are accuratv attd determined using standard duct testing protocol. Company Nama: �f C.✓��� ��4'� —Technlclan�_�1 �-�''�.:�/�-✓��`� 7echnfclan Slgnature:, - Date: � • Phone Numher:_ ��j7 - � �