20130185 Permit Pkg 05102013 o� �' City of Yelm Permit ►vo.: 20130185
,� Community Development Department Issue Date: 5/10/2013
� (Work must be completed within 180 days)
Building Division
Phone: (360)458-8407
"""»""""" Fax: (360)458-3144
Applicant:
Name: FREESTONE Phone: 253-896-1300
Address: 6820 20TH ST E STE A
FIFE WA 98424
Property Information:
site Address: 15329 KAYLA ST SE 55 Owner: FREESTONE INC
Assessor Parcel No.: 41610005500 Subdivision: CHERRY MEADOWS Lot: 55
Contractor Information:
Name: FREESTONE Phone: 253-896-1300
Address: RICK CARLILE
6820 20TH ST E STE A
FIFE WA 98424
Contractor License No.: FREESI"969NZ Expires: 1/24/2011
Project Information:
Project: NEW RESIDENTIAL BUILDING
Description of Work: LOT 55, PLAN 2758A
Sq. Ft. per floor: First 1248 Heat Type(Electric, Gas, Other): GAS
Second 1516
Third
Garage 400
Basement
Fees:
Item Contractor Fees
NEW RESIDENTIAL BUILDING FREESTONE $16,601.91
MECHANICAL KLIEMANN BROS. $ 78.25
PLUMBING PELTRAM PLUMBING $ 118.00
TOTAL FEES: $16,798.16
Applicant's Affidavit: OFFICIAL USE ONLY
I certify that I have read and examined the information contained within the application and know the same
to be true and cor t. I also certify that the proposed structure is in conformity with all applicable City of #Sets of Prints:
Yelm regulatipns i cluding those governing zoning and land subdivision,and in addition,all covenants,
easements and strictions of r d. If�pplyin as a contractor, I further certify tha I am urrently
, Final Inspection:
registe ed in e State of W ingt .
Signatur Date� `� �3 Date:
Firm BY'
Cit� of y�lm
(3� ) 458-B4U2
REC#: U0127351 5/lU/2013 1U:26 Ahi
OPER: CO TERM: 001
REF#: i117
TRAN: 33.�000 BUTLGING PERMTTS
20130183 17,709.79CR
FREESTQNE
15432 CNAD DR SE �3
BL.�-RE51 17,452,54CR
MECH 78�25C1�
P� 139.00CR
TRAN, 3;3.t10UU BUILi7ING �El�MITS
2�130184 17,471.23CR
FREESTONE
154�8 CHAD DR SE Z4
�LD-RES1 17,253.98CR
M�CH 78.25CR
pL 139.00CR
TRAN: 33.G000 9UILaING PERMIiS
?013t1185 16,798.16L'R
FRFESTONE
15329 KAYLA ST SE 55
BI_D-RE51 16,601.91CR
MECH 78.25CR
PL 118.GOCR
TENDEf�ED: 51,979.1E3 GNECK
APPLIED; 51,97�.1�-
CHkNGE: _._.__�__ �,OD
YEiM COMM�hZTy $�HOOLS
YELM Wq gg597
Clerk: �roy
Terminal;
Receipt: 207398
Manua( �eceipt:
NFREESTutJE
FREESTQNE� �.LC
6$20 �OTH ST E SUTf� k
FIFE, WA 98424
�I10/2013 1�:0� AM
��.��I t�m
------.__.__.__--_ Pr i ce
� CFF MITIGpTION
MITIGATIUN 3015.00
G3-021/LOT 23/15432 CNAD DR SE;YELM
� ��PF MITIGAiIDN
MITIGATION 3015,00
U3-021/�OT 24/15438 CNAD DR SE;YELM
� ��F MITIGATION
MITIGATION �415.00
03-021/LOT 55/1532.9 KAYLA ST SE;YELM
$ubtotal; 9045.00
Tax:
Total: �.00
9045,00
Check 9045.00
2118
Change Due: 0.00
THANK YOU
����` �
CITY OF YELM
RESIDENTIAL BUILDING PERMIT APPLICATION FORM
Project Address:��J' �a� �� � �'�iarcel#: ���(On�.�Q O
Subdivision: �ot#:_� Plan#: `s a
Zoning:
�Q New Construction ❑ Re-Model/Re-Roof/Addition ❑ Home Occupation Sign
❑ Plumbing 0 Mechanical ❑ Mobile/Manufactured Hom lacement ❑ Other
Project Description/Scope of Work: � ' Q
Project Value: av�� � ,`''
Building Area(sq. ft) 1"Floor �c�. 2"d Floor��i Garage � ��_
Basement ` Carport �p '
atio�
#Bedrooms� #Bathrooms��
_�� Heating:�OTHER or ELECTRIC (Circle One)
Are there any environmentaily sensitive areas located on the parcel? �_
If yes, a completed environmental checklist must accompany permit application.
BCJtL01NCx�.OWNE�NaAA�:
ADDRE S O EMAIL ' .��
C�N � STATE �
-J�.__Z�P TELEPHONE (o- �
AR��I��`�i�'yC'/�N�t(V��l� UCENSE#
ADDRESS EMAIL��q , C Lq,�,
C�N�h2-� STATE ZIP ► TELEPHONE � ���
GENERA�CC1N7�CTOF� TELEPHONE � =
ADDRESS EMAIL �q d
CITY�rmE STATE IP FAX C $q!o-d(o 60
CONTRACTOR'S LICENSE# 2 EXP DATE CITY LICENSE#
PLUMBIIV�Ct�N'1'RRCa't`t� e ��
ADDR SS LEPHONE �-
C�T.�, EMAIL
STAT Z 0 FAX (2��, 9 1 ..4�.
CONTRACTOR'S LICENSE# EXP DATE CITY LICENSE#
� ao
MECNANtCA�EE3NTFtFt�TOt� • Ic TELEPHONE a6 5 -D
ADDR_„SE,SS �}703 l�(�'� S1- � EMAIL
CITY Ia.Qjpry�q„ STATE ZIP - _ _ -/= F,qX (
CONTRACTOR'S LICENSE#kt,rENl�N01 RT EXP DATE� CITY LICENSE#
Copy of mitigation agreement with Yelm Commurnty c�is if applicable.
I hereby certlfy that the above Informatlon Is correet and that the construcUon on,and the oceupancy and the uso of tha
above cribed p�operty will be in accordanca wlth the Iaws,rules and regulatlons of the State of Washington and th•
CI f Ye .
' � /
A li nt's Signatur � a�°
Owner/Contractor/Owne�'s Agent/ ontractor's Agent(Please circ�le one.)
All permits are non-transferable and will expire if work authorized by such �
withtn 180 days of issuance,or if work 1s suspended or abandoned for a p r�od.�:��0: e' s �
I�� ;
� �pR � 9 2013
�
'r�`�.
1 5 Yelm Avenue Weat ` '
Yelm, WA 98597 (360)45&3835
www.ct.yelm.wa.ua (360)458-3144FAX
6.5' 17' 20' ' 6.5'
52.00
OT OT �p
54 55
� r10 CY �
DRVWELL
L —
_ �
SCALE:1"=20' I �, � COV PATIO � N
N � I I N
I 39 �
� �
� 2758 A STD �
� DIAG 60.31' �
�
I �'
� � I �
I -
� 6.5' 3 W 6.5' o
� I GARAGE B� (5, �� o
I18.5' c.o.
I COV.PORCH
� II �
20.5'
— — — Q —
5'•0' � y
CONC. STEP{(�
DRIVE 11'-11" • �8A7" "� 5'-10I SEPAR4TION
OR SLEEVE
/ - WATEft LINE
�
N �/ N
�
10'UTILITY ESMT 5��%���� �
,//
/
s
52.�� W
0
caOV APPROXIMATE CURB/GUTTER
LOCATION OF 9 �°y <<<
STREET TREE ����j � ` �'- -�`°'�
a
,�,�.�..���;`-�j�f .
—————————————— —
K�YL� 5T. 5� ._ ;.j� _._
, (� '
NO 5 EAVE 1 �._i �� � ���
ENCROACHMENT THIS LOT
CONNECT 4" PVC ROOF
STEP TANK EXCAVATION IN VIOLATION DRAINS TO DRYWELL
OF THE REQUIRED 5' MINIMUM SET BACK FRONT PORCH FOUNDATION AND STEP
TO FOUNDATION SHALL BE BACKED TANK LOCA � � UT
FILLED WITH CDF. FOR SET B CK INSP�CT'1 . � '
LOT 55 - CHERRY MEADOW Ap� � � ����
PARCEL #: 416100 055 00 owner: '
Gh� Meadows LLG
Lot Size: Pro�ect Address: 6820 20th St. E Suite A
�ife, WA a8424
5,200 Sq. Ft. 15329 KAYLA ST. SE 253-8q6-1300
,. �,:
a
` Prescriptive Energy Code Compliance for Single Family and Dupiex Housing: Zone 1
Project lnformation Contact lnformation
Plan 2758 Freestone Com anies 6820:20th st E
Yelm Fife WA 98424 253-896�1`30Q
Rick Cariife 253=381-6080`
This set of forms has been developed to assist permit applicants documenting compliance with the
Washington State Energy Code, (2009 edition). This set is for structures built under the IRC and located
in Climate Zone 1.
The following forms provide much of the required documentation for plan review. The details noted here
must also be shown on the drawings (WSEC 104.2).
This form is not a substitute for the energy code itself. To obtain a copy of the energy code,
go to the following web address. http://www.energy.wsu.edu/code
Glazing iz a a
to Glazing U-Factor poor 9 Vaulted Wall Wall• int Wall• ext Slabb
Option Area : z
Ceiling 3 Above Below Below FloorS on
%of Floor Vertical Overhead�l U-Factor Ceiling Grade Grade Grade Grade
R-49 or
OO I 13% 0.34 0.50 0.20 R-38 R-38 R-21 R�21 R-10
Int.� TB R-10 R-30
Adv.
2'
R-49 or R_21 R-21
O II 2$% 0.32 0.50 0.20 R-38 R-38 R-10 R-30 R-10
Adv. Int.' TB 2�
R-49 or R-21
O III pnlimited 0.30 0.50 0.20 R-38 R-38 R"21 R-IO
Adv.
Int.� TB R-10 R-30 2�
See WSEC table 6-1 for footnotes
Glazing Schedule Attached to Document
� Does not apply. (SEE INSTRUCTIONS) Usin� Prescriptive Option III All glazing
and doors meet maximum U-factor. Alternate heating size method submitted.
0 Option I or II,Glazing to flvor area limit (WSEC 602.7.2)
❑ Area weighted window,skylight or door U-factor(WSEC 602J.2)
O As part of the heating system sizing calculation (IRC M1401.3 &WSEC 503.2.2)
Radiant slab:
❑ R-10 foam insulation, continuous with thermal break (WSEC 502.1.4.9)
Chapter 9 Options Total of 1 Credit Reauired
Opt. Opt. Descri tion
1a Hi h Efficienc HVAC Equi ment 1 1.0 Cl
1b High Efficienc HVAC Equipment 2
1 c Hi h Efficienc HVAC Equipment 3
2 Hi h Efficienc HVAC Distribution S stem
3a Efficient Buildin fnvelo e 1
3b E�cient Buildin Envelo e 2
3c Su er-E�cient Buildin Envelo e 3
4a Air Leaka e Control and Efficient Ventilation
4b Additional Air Leaka e Control and Efficient Ventilation
5a Efficient Water Heatin �.�,���E�
5b High Effiecienc Water Heatin
6 Smal1 Dwellin Unit APR 2 9 2013
7 Lar e Dwellin Unit
8 Renewable Electric Ener �� 1200 kwh
Total Credits 1.00
WSEC Prescriptive Worksheet(2010 edition)Zone 1 WSUEEPIO-010 Copyright 2010
� Glazing Schedule
Project/nformation Contact Information
Pian 2758 Freestone Com anies 6820 20th st E
Yelm Fife WA 98424 253-896-1300
Rick Carlile 253-381-6080
Conditioned Floor Area < 2758 Sum of UA for Heating System Sizing 118.8
Sum of All Glazing Areas From Below 340
Giazing to Floor Area Ratio 12.33% 602.7.2 Exception Ratio(not to exceed 1%}�
Exterior poors
Plan Component Door Percent Width Height Glazing Door poor
ID Descri tion Ref. U-factor Glazed Qt. Feet '"°n Feet �"�' Area Area UA
� Interior to ara e fiber tass fire-rated 0.160 �� � �1ti. ;; 3 °�,�� � ��- . < 20.0 3.2
��,, ;:��� �::
�:
`, .5� One Exempt Swinging Door<24 Square Feet 1�-� '��. �.� `' � ��;��.: � 2�.0
Sum of Glazing Area, Door Area, and UA (do not include exempt door) 20.0 3.2
Area Weighted U= UA/Area 0.16
Sum of Area and UA for Heating system size only(include exempt door) 40.0 3.2
Vertical Glazing (Windows, Glazed doors using Exception 602.6#1)
Plan Component Glazing Width Height Glazing
1D Descri tion Ref. U-factor Qt Feet �"°n Feet �"�' Area UA
2 I, Low-e1 1/2"+ ar on 0.340 1.�" � � `� 5 ,, � ,'� � � 30.�0 1D.20
2 I, Low-e1 1/2"+ar on 0.340 � 1�� 6,. �._ : � ��> �� � � � � 47.0 � 15.98
2 I, Low-e1 1/2"+ ar on 0.340 � � 2 -�: �� �" °�_ � • �;�� �� 32.0 � 10.88
2 I, Low-e1 1/2" + ar on 0.340 � 3.�:.:� 5� , ��b'�� 5 ° � 75.0 � 25.50
2 I, Low-e1 1/2" � ar on 0.340 � 4�.-,°�� � � � -���� �,� : ���� � � �0.0 � 6.80
2 I, Low-e1 1/2" + ar on 0.340 � 2�..:� � �.� ��_ `��;e 48A � 16.32
2 I, Low-e1 1/2"+ ar on 0.340 � 4 :�" ��z� ;�, F' ��, :�,;-� � � 80.�E} � 27.20
2 I, Low-e1 1/2" + ar on 0.340 � 2 ;`°� ��. . :�.`��� �`� .� ���:;� 8��A � 2.72
2 I, Low-e1 1/2"+ ar on 0.340
2 I, Low-e1 1/2" + ar on 0.340 � �
2 I, Low-e1 1/2" + ar on 0.340 .��� ��, �s �, ;=.o
2 I, Low-e1 1/2" + ar on 0.340
�-> �� �� � � �
��.
:
_� �,
��, ;:4
#.
= ���. �,.;, ,� , :., .. . �. .
Sum of Area and UA 340.0 115.60
Area Weighted U= UA/Area 0.34
WSEC Prescriptive Worksheet(2010 Edition)
WSUEEPIO-010 Copyright 2010
` Overhead Glazing
Plan Component Glazing Width Height
�� Descri tion Ref. U Qt. Feet �"`" Feet �"`n Area UA
4:��,,
Sum of Area and UA
Area Weighted U= UA/Area
Doube Glazed Garden Windows Section 602.7.2 Exception
Plan Component Width Height
�� Descri tion Qt. Feet �"`n Feet '"`n Area UA
Sum of Area
Sum ofArea X 3(This total is automarically included in the glazing area total.)
Glazing UA for Heating System Size Only=Area X 0.63
WSEC Prescriptive Worksheet(2010 Edition)
WSUEEPIO-010 Copyright 2010
.
' � Simple Heating System Size: Climate Zone 1
Project Inforrnation Contact/nformation
Pian 2758 Freestone Com anies 6820 20th st E
Yelm Fife WA 98424 253-896-1300
Rick Cariile 253-381-6080
Indoor Design Temperature 70
Outdoor Design Temperature 17
Design Temperature Difference(�T)
OT=Indoor-Outdoor Design Temp 53
Conditioned Floor Area 2758
Conditioned Volume 23306
Glazing
Copy Sum of UA from Glazing Schedule 119
Attic U-Factor X Area - UA
R-49 0.027 1516 40.9
R-38 Advanced 0.026
Single Rafter or Joist Vaulted Ceilings
U-Factor X Area = UA
R-38 Vented 0.027 � �
Above Grade Walls U-Factor X Area = UA
R-21 0.056 2432 136.2
Floors U-Factor X Area = UA
R-30 0.029 1242 36.0
Below Grade Walis U-Factor X Area = UA
2' Depth Walls 0.042
3.5' Depth Walls 0.041
7'bepth Walls 0.037
� �_�
Slab Below Grade F-Factor X Len th = UA
2' Depth 0.59
3.5' Depth 0.64
7' Depth 0.57
� �--�
Slab on Grade F-Factor X Len th = UA
R-10 2' perimeter 0.54
R-10 Full- Heated 0.55
Sum of UA 332
Envelope Heat Load 17593 Btu/ Hour
Sum of UA X aT
Air Leakage Heat Load 13340 Btu/ Hour
((Volume X 0.6)X OT)X.018))
Building Design Heat Load 30933 Btu/Hour
Air Leakage+Envelope Heat Loss
Building and Duct Heat Load 1.15 35573 Btu/Hour
If ducts are located in unconditioned space:Sum of Building Heat Loss X 1.15
If ducts are located in conditioned space:Sum of Buiiding Heat Loss X 1
Maximum Heat Equipment Output 150% 53360 Btu/Hour
Building and Duct Heat Loss X 1.50
WSEC Prescriptive Worksheet(2010 Edition)
WSUEEPIO-010 Copyright 2010
�
�1 ��1� I�S
.����i
,� � � � s � � �
��, ��� NORTHW � ST
�°�xxw�'
Insulation Certificate/Blower poor Test Form
Batts&Blankets Thermal Performance(Attic Application)
When installed in accordance with tUe manufacturer's The stated thermal resistance(R-value)is provided by installing in accordance with the manufacturer's
recorrmiendations,Knauf Batts&blankets will provide instiuctions,the required number of bags per 1,000 sq.ft.of net area,at not less thui the labeled minimum
the full R-value. thickness.Failure to install both the required number of bags&at least the minimum thickness will result
in lower insulation R-value. �
, _ _ _
- _ _ _ _ _ _
R-Value Minimum Thickness R-Value Bags/1,000 sq.ft. Maximum Coverage Minimum Weight Minimum Thickness
To obtain a�� Instal]ed insulation To obtain an The mimber of Contents ofthis bag The WeighUSF of Installed insulation
insulation resistance should not be less insulation bags/1,000 SF of ne should not cover more installed insulation should not be less
R-Value of: than: resistance area should not be than: should not be less than: than:
(1t-Vaiuej of:
R-38 HD 1025" I2-60 29.7 33.6 SF .952 lbs. 19.750" _
R-3S 12.00" R-49 23.5 42.5 SF .7531bs. 16375"
R-30 HD 8.25" R-44 20.9 47.8 SF .6701bs. 14.875"
R-30 10.00" R-38 17.8 56.2 SF .5691bs 13.000"
R26 9.00" R-30 13.6 73.3 SF .4371bs 10.375"
R-22 6.50" R-26 11.8 85.0 SF .377 Ibs 9.125"
R-21 HD 5.50" R-22 9.8 1022 SF 313 lbs 7.750"
R-19 6.25""" R-19 8.4 1193 SF .268 lbs 6.750"
R-15�ID 3.50" R-13 5.7 1753 SF .1831bs 4.750"
R-13 3.50" R-11 4.7 210.8 SF .1521bs 4.000"
R-11 3.50" Bag Weight-Nomina130 Ibs,Minimum 291bs.This product conforms to the performance requirements of ASTM C 764,
R-8 2.50" Type 1,&cancelled Federal Specification HH-1-1030B,Type 1,Blass B.R-Values are determined in accordance with
��`R-18 in a 5.5"cavity.Conforms to ASTM C 687&C 518."R"means resistance to heat flow.The higher the R-value,the greater the insulation power.To get the
� C665&Federal Specification HH-1-521F inarked R-vahie,it is essential that the insulation be installed properly.If you do it yourself,get instructions&follow them.
To achieve labeled R-value,this product must be applied�vith a pneumatic blowing machine&a corrugated hose with a minimum.ZS"internal corrugation,a minimum lenb h
of 150 ft.&a diameter of at least 3".Coils in the hose should not be less than 36"in dianieter.Acceptable material feed rate is 5-351bs./minute.Recommended feed rate is
15-25 Ibs./minutes.
Buildeis Insulation 5tatement.
Batts a�id/or Ulankets have been installed in conformance with the above 2009 WSEC Residential Enersy Comnliance Certificafe-Building Air Leakage
recommendations to rovide a thermal resistance of....
R-Value Standard Building&Test Conditio : Comments:
AtticArea R- R-49 Date: '�(` __
Ext.Walls R- Z R-21 Time pD0
Inter.Walls R- R-ll Indoor'I'emp: b
Sprinkler Tenting R- R-8 Outdoor Temp:
Knee Walls R- R-21KF Floor Area(sq ft)
Under floor R- R-30
Completed as of: "!'L�!��✓ 1Buildina Air Lealta�e Tar�et: SLA Less 7Chan 0.00030
Installers Name Print: _ TesE#1-Depres, _�_Press Pretest Baseline Pressure _(Pa)
Installers Name Sign:
Bldg Press.(Pa Florv Ring Fan Press.(Pa Flow(cfm)
J532� �uE �.� j<-vT #55 �3 i ' ' ` �- [�zo
Site Address: �-3
���/�( �C�S 97 Post Test Pressure: Fan ModellSN:
Results:SLA(Specific Leakage Area): . ����Q l� 3'2��
Home Builders Signature: Test#2-Depress _Press Pretest Baseline Pressure (Pa)
Home Builders Address:
Bld Press.(Pa Flow Ring Fan Press. a) Flow(cfm
Insulation Contractor: Insulation Northwest LLC
Post Test Pressure: Fan Model/SN:
P.253-846-0121 P.O.Box 732069
Results:SLA(Specific Leakage Area):
F.253-846-8096 Puvallup WA 98373
Affidavit I certify that this Specific Leakage Area is accurate&determined using Blower poor Test Standard 502.4.5 Building Air Leakage Testing.
Technician Name Print: �� ',c_J�l�s Technician Name Sign:
� Sep, t9. 2013 2:38PM Kl i emann Bros NVAC �j�o, 2�j��� p �
. � � 5
� t, � � ,�,
�-e� ��.dc�s C�
� . .
Auck Lt�a1CA�e Af11d&w'iE -
Perm(t#: �G��� r��„
House�ddress or Iot numbet:. ���� �1 t� �
C1�y: 7�P�E/YI zip;
Cond, Floor Area(Yf�:��,�„� Seurco(clrcle one): "�ar �sttmefed Memsured
�bu�ti8htness testing ts not required for this resTdence per exceptlons listed st the end o1'this docum e�t
Air Nendler in cartditioned space?[�yes 0 no Atr Handler preaent during tesE7 Q'yes�no
Clrcle Test Method: Leak�ge�o Outside Tota!�.eak�gg-
M�x/tnum du�!/oAk�ge;
Pvst Constructlon,tota�ctuct foakage:(floar area x.08)��C�M(�25 Pa
Post Construaticn,leak89e to outdoors: (t�oor area x.Ofi)= CFM�25 Pa
Rough-�n,total ducti leakage with �Ir ha�dlor Installod:(iCoor g,rea x.06)-��CFM�25 Pa
Raugh•In,total dact teakaga wlth a!r�andler not[natialled:(ttoor aree x.04)� CFM(�2S P�
Teat Rosuit:���CFM(�226Pa
Ring(oircle one If spplicable): Open 9 2 3
Duct Tester Location: � � �ressure Tap Locatlon:� �' /���S� � �
�
I certtfy that these duct leakaee rates are acaurate and determined usin standard duct teatln9 protocol.
Company Name:,����1�%�' 78chntclatt: �''�
Technlclan Slgnature:_ Date: � �hone Number:�7=L��,�
Wa�ftthpton 9tete 8naryy Cvtle referenCO: '
so3.�10.3 sozltna,Aft�cts,�ir hondlars,lpter boxes,anQ bc�AAin9 c�vt(fes usod as ducts aRa11 be semtod.Jdnts ar�eeamr sh011 comply
with Ssd)pf1 Nil60f,3 of tNo/n�amaflpnpl R�sldcrrBaJ LbdO or 803.9 0�U1e lnlernstloAr/Merlienl0�!Coda puat Uphtnoao tea�l�na shab pe
oonduoted Eo ver)ty thai the duot�aro eealod�A afgned offld�vlt documsn�Mg Thr�st roculta sh�ft be proVtded to Ihe JU►isdidion heNng
�tUtorfly by Me ea�t}n�eQenG 1Uhen requlrpd by the b�lldl�g oRlclsl,fhs teat eheN be oonduvlvd ln Ihe prosonoo W depa�ttnent claK •
ExCepllons: 9,Duct tiflhtAeee testi6 rtol roquirod KtAe air handlet ahd all dyots sre laoetea wilhin aonQ(lioned spaoo.
2-�uCt testlny Is qot roqulrod!t 1�n furnace le e nondlrepl venC type oomDusHon aDDaenoe fnstallotl ir1 an unopnaitfoned apeCe,
A mmd�urn o�s6c foo4 of Oo�neclod duetwnrk h11110 u�condltlonad space La eROwed.A11�Qdtllonal se�pp)y Qnd rolurr�dutta
�hall be wtlhlh Ih•conGlUoh�d spnta.Duc[s oukalQe!he conmtlor�ea spar�a sh�ll Da sonteGµqih q mavtto�.dust gsafene and
InsUlated on the extetlor Wtth 1�8 insulatlon tor aboVe g�ade duola ertd I�'�vrpler reatslent inoutation wh�w{thfn a alnb or
oortr�.
�
Z000/i000 �j SMOQ���t 1�2I2i�H� �NOZS��2i3 bL0T8�i�09� X@3 Nid i�0�� ETOZ/6i/60
U
M �O
N �
Q � �
� � �
� i � �
N � � �
� � � i
� � � � � �
� � � U��N
� � � �
� s�, a� � Cj o >.
� � U �
� �
N � Z � c � >
q � � � � �
� � � ��
ti � � �- � � �
�+ � � � m �
� o � �
� Q �'J (lT (a N
0 '� .� c � a�
N � a? � o
'� paj � � � -�
�
•1�l � � N � C
V � � �
�v "� L
� � � � N
�� �� � Q � � �
� � W � w c � L
H
� Q
� � � _ � d- � c6 ��
W ca
�p .4� � W � cj � � o � U
� � g �
z cA �' C� �- o
� � � o � � Q � � .cn � �
n1 � � w cn
N w Q p W � � � J � (a
� W N L.L � N O �' +�-'
� � � � � � Z J U �
N g Q C� cn
�
� � � ~
cn Z F— �
N � +� � "� O . .
� �. c6
�!�'tE s L E J U '� �U
4�� .:�? � � � N Q � `�
� '�� � Q � � � � O
� a� � z Q � .� � U rn
W � � � � c`a cn � c
o�; � � � � � � c� '� �
�`�'�'�`' m O O m � Q c� m