20130142 Permit Pkg 04242013 o�e �' City of Yelm Permit No.: 20130142
� Community Development Department Issue Date: 4/24/2073
� (Work must be completed within 180 days)
Building Division
Phone: (360)458-8407
""' """'°" Fax: (360)458-3144
Applicant:
Name: FREESTONE Phone: 253-896-1300
Address: 6820 20TH ST E STE A
FIFE WA 98424
Property Information:
site Address: 15337 92ND AVE SE 108 Owner: FREESTONE INC
Assessor Parcel No.: 41610010800 Subdivision: CHERRY MEADOWS Lot: 108
Contractor Information:
Name: FREESTONE Phone: 253-896-1300
Address: RICK CARLILE
6820 20TH ST E STE A
FIFE WA 98424
Contractor License No.: FREESI"969NZ Expires: 1/24/2011
Project Information:
Project: NEW RESIDENTIAL BUILDING
Description of Work: LOT 108, PLAN 3115A
Sq. Ft. per floor: First 1318 Heat Type(Electric, Gas, Other): GAS
Second 1796
Third
Garage 555
Basement
Fees:
Item Contractor Fees
NEW RESIDENTIAL BUILDING FREESTONE $17,293.74
MECHANICAL KLIEMANN BROS. $ 78.25
PLUMBING PELTRAM PLUMBING $ 118.00
TOTAL FEES: $17,489.99
ApplicanYs Affidavit: OFFICIAL USE ONLY
I certify that I have read and examined the information contained within the application and know the same
to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of #Sets of Prints:
Yelm regulatjerts cluding those governing zoning and land subdivision,and in addition,all covenants,
easements and r strictions of record. If app ing as a contractor, I further certify tha I am cur ntly Final Inspection:
registered in t tate of n t .
Signatu � G��-%��� � Date - f � ( � Date:
Firm � By�
Cit� of Y�lm
�3� l 458�-84Ci�
�EG#: �012.5930 4/24/2(l13 3:5U F'M
OP�R: CO TkRM: 001
REF#; 2U9ra
�(RAN; �3.(10�J� BIJ17�3�6.h1GR1TS
�U13017B
F��ES�fONE
15352 92ND AVE SE 90
aLG-RE�1 17,190.3bC�
MECH 78.25CR
PL 118.00GR
TRAN: 33.OUOU BU1��489.99CRT�S
2013(�14'1
FREESTONE
1`+337 92NU AVE SE 108
8LD-RES1 17�293.74CR
MECN 78.25CR
P� 118.OQCR
�I�ENDE�r�D� ��,g76.6Q.- CH�GK
APPLIED:
___.._�_____0.0�
CNANGE:
YEL� �PO�ROXT4T��H�OLS
YELM WA 98597
�ler�k: Croy
Terminai : �
Reczi pt; ?.05376
Manaal 2eceipt;
NFREESTONE
NFREE5Tt7NE
FREESTONE, I.LC
682�� 20TN �T E SUITE A
FIFE, WA 98424
4J2�/2013 3:3y NM
�itY_---It�m------.______. _Price
� �^Pr �1ITIuAiTuN �aj�•�a
MITIGATION
u3-J21%i.OT 90/153�2 92N0 AVE SE;YELM
1 �1ITIGATIONTi�N 3015.00
�3-021/L.OT 108/15337 92ND AVE SE;YELM
5ubto�a1 ; 6030.00
Tax:
Totai ; 6030.00
Cner:k 6C30.00
2C�96
Ci��ar�g� Due: 0.00
THAidK Y�7U
CITY OF YELM
RESIDENTIAL BUILDING PERMIT APPLICATION FORM
� Project Address:_IS3�J7 �oZ,hd hQ� Parce�#: �'I�o(OO�D � OO
Subdivision: � �ot#: ��D Plan#: 3��5� Zoning:
�Q New Construction ❑ Re-Model/Re-Roof/Addition � Home Occupation Sign
❑ Piumbing ❑ Mechanical ❑ Mobile/Manufactured Hom lacement ❑ Other
Project Description/Scope of Work: ' t , Q
Project Value: J�V
Building Area(sq. ftj 1"Floor ��J' �g 2"d Floor� �P Garage�5 g� �
Basement "'— Carport ^ �o'��(p
#Bedrooms� #Bathrooms �
���._, Heating:�OTHER or ELECTRIC (Circle One)
Are there any environmentally sensitive areas located on the parcel? �_
!f yes, a completed environmental checklist must accompany permit apptication.
BUtLQINGvE71NWEE�IVAM�:
ADDRE S O EMAIL ' .��
C�N � STATE�_ZIp TELEPHONE (o-
ARe�!!'F�t�T���t1�,,[(�IEEI� LICENSE#
ADDRESS a - EMAIL 1��hq �qnnc_a,,,
C�n' Bal-he.1 STATE ZIP ► TELEPHONE ���
GEN�RA�.CQIy1'RqCI'C�f� TELEPHONE_ �m"
ADDRESS EMAIL -r`�q—�—
CITY�rN� STATE IP FAX �o2F�� $q(o-O(c 6p
CONTRACTOR'S LICENSE# 2 EXP DATE CITY LICENSE#
�0141
Pf:l1MBINC�CCXtVTFCi4E:TC�F�' e LEPHONE l-
ADDR SS EMAIL
CITY STAT Z p FAX �25� 9 l•4�
CONTRACTOR'S LICENSE# EXP DATE CITY LICENSE#
I �p
MEeHANtG�kL CQNI'F�t�TOi� • K � TELEPHONE a6 5 -D
ADDR�,SS 0 '� ' EMAIL
CITY IQ.Qpry�CL STATE ZIP F,q)(
CONTRACTOR'S LICENSE#kl,rENIP�NOZI BT EXP DATE� CITY LICENSE#
� 'a.`7 201+{
Copy of mitigation agreement with Yelm Commurnty Schools, if applicable.
1 hereby certlty that the above Iniormatlon Is correet and that the construction on,and the occupancy and the usa of tho
above deserlbed property wlll ba In accordanea wlth the laws,rules and regulatlons of tha Stats of Washington and th•
Clty Yelm.
Appllcant's Signatur Date !
Owner/Contractor/Owne�'s Agent/ ontractor's Agent(Please clrcle one.)
All permits are non-transferable and wlll explre if work authortzed by such permit is not begun
withln 180 days of tssuance, or If work Is suspended or abandoned for a perlod of 180 days
�,,` _� .:���:;��,r�D
�. APR 1 � 2013
105 Yelm Avenue Weat (360),46�3835
Yelm, WA 98597 (360)458=�144�
www.ci.yelm.wa.ue
6' 18' ....____ ____.._....._�_9�..........._....... ._��
,�_.._� ___..—.52.00
-- -*—_._.�
SCAIE:P=10' � _ � {8 109
�"> � 10 Y � �1-- �
D YWEI.L � I
N _�_.._._.� � " _.� ___ __ — _ � _.. �� N
i 18 x 12 �
N COV PRTIO I'r' ROOF
� �� DRAWS� �
_�,____.._. — — � — —
� � 39' w �
� \ 3115 A STD �
� DIAG 63.41' �
�
� ', (4 BDRM)� '
ol 6 ' ' i 7� o
�n) ( j � u�
I O � ' _� � O
I °o � ' 2 CAR I °o
j `� � GARAGE ; `-
i '
8, c.o. I
� � co�.roaa, 22, \ 1
,_b � � � ._ . �.__,.�..__
� P - - I
� ;, y^ � CONC. �
; r�K DRNE
� �T. ' �
(y l N 5,�, ...;8,7,�' 70,N` ._._.... N
Q 10'UTit,ESMT �� (
/ 7
0
CJ •-
� CONC WALK rj�,OO W
St���� 7��r1k E�xca�at�rorf Ir� V�ic�latic�n C�r i
Th� }�r ����:�� ,' M��;rr�t�rrz SeE Back ��a �___..____
PLANTERfi' � ;�� .s`
i nt3r�t�at�;r� S��al! 8�= #�ack fil`ied �1iSh _.__ _ I i�—
C C?� cuRe i curreR�_� APPROXIMA7E N " SC:.�'`��
LOCA710N OF GG t�a (`D r�
Frt?r�! P<z��r.���� ��u�;x7t�aT!K?;� Ant1 St�� T�rak STREET7REE
�Lir;d+!{7`i Jt!d�? �F' S(d�tE't� �-O� �aFT �cl(.:�5
�i,s,,ecz,�n �,._..__ �2nd A�Y�N�1E S��y
{)N WEST S�IDE�OF TH SN UT A�����.�''�{��' `---I� F I � �.
/ �
L�� ,���-�, .� , � coN�v�c�r�° �vc Roo�
�TEP TANK EXCAVATION IN VIOLATIUN DRAINS TO DRYWELL
_ ,,,.� .«_�._.._....
-; �
�
OF THE REQUIRED 5' MINIMUM SET BACK � ` ' � .` f4"`"�'"`""""�
""`""~ �" �"� '' FRONT P(JRCH FOUNDATION AND STEP
TO FOUNDATION SHALL, 8E SACKED ' TANK LUCATION SHALL BE STAKED OUT
FILLER WITH CDF. FQR SE7 BACK IN,
LUT 108 - CHERRY MEADU'1!V'�; j ,r '
, {'. .$ � L'+�.7 �
PARGEL. #: 4161�0 1 U8 00 ow�,e�: Free�tone �
Gherru Nteadaw�t�:�==_�
Lot Size: Pro�ect Addresa: �iS20 20th 9t. � Suite ?�
5,20� Sq. Ft. 15337 92nd AVENUE SE 2�3-aa��a o0
� wrescriptive Energy Code Compliance for Single Family and Duplex Housing: Zone 1
Project/nformation Contact Information
Plan��3115 �� F�eestorte Inc; Fife�WA 98Q24� � ��
253 89�t30Q�_ �
Yelm�� � Rick Carlile�Gelt 253�-381-6080` A�
This set of forms has been developed to assist permit applicants documenting compliance with the
Washington State Energy Code, (2009 edition). This set is for structures built under the IRC and located
in Climate Zone 1.
The following forms provide much of the required documentation for plan review. The details noted here
must also be shown on the drawings (WSEC 104.2).
This form is not a substitute for the energy code itself. To obtain a copy of the energy code,
go to the following web address. http://www.energy.wsu.edu/code
Glazing
io Glazing U-Factor poor 9 Vaulted Wa1112 Wall• int° Walt• eact4 Slabb
Option Area : Ceilingz 3 Above Below Below Floors on
%of Floor Vertical Overhead'� U-Factor Ceiling Grade Grade Grade Grade
R-49 or R_21 R-21 R-10
OO I 13% 0.34 0.50 0.20 R-38 R-38 Int.' TB R-10 R-30 2,
Adv.
R-49 or R-21 R-21 R-10
O II 25% 032 0.50 0.20 R-38 R-38 Int.' TB R-10 R-30 2,
Adv.
R-49 or R-21 R 21 R-I0
O III Unlimited 0.34 0.50 0.20 R-38 R-38 Int.� TB R-IO R-3D 2,
_ Adv.
See WSEC table 6-1 forfootnotes
Glazing Schedule Attached to Document
� Does not apply. (SEE INSTRUCTIONS) Usin� Prescriptive Option III.All glazing
and doors meet maximum U-factor. Alternate heating size method submitted.
� Option I or II,GJazing to floor area limit (WSEC 602.7.2)
❑ Area weighted window,skyligh#or door U-fattor(WSEC 602.7.2)
� As part of the heating system sizing calculation (IRC M1401.3 &WSEC 503.2.2)
Radiant slab:
❑ R-10 foam insulation, continuous with thermal break (WSEC 502.1.4.9)
Chapter 9 Options Total of 1 Credit Reauired
Opt. Opt. Deseription
1a Hi h Efficienc HVAC Equi ment 1 1.0 O
1 b Hi h Efficienc HVAC Equipment 2
1c Hi h E�cienc HVAC Equi ment 3
2 Hi h E�cienc HVAC Distribution S stem
3a Effrcient Buildin Envelo e 1
3b Efficient Buildin Envelo e 2
3c Super-E�cient Buildin Envelo e 3
4a Air Leaka e Control and E�cient Ventilation
4b Additional Air Leaka e Control and Efficient venti�ation ��cEI�E�
5a Efficient Water Heatin
5b Hi h E�ecienc Water Heatin APR 18 2013
6 Small Dwellin Unit
7 Lar e Dwellin Unit � .
8 Renewable Electric Ener
Total Credits 1.00
WSEC Prescriptive Worksheet(2010 edition)Zone 1 WSUEEPIO-010 Copyright 2010
, Gl�zing Schedule
Project Information Contact Mformation
Plan 3115 Freestone Inc, Fife WA 98424
253 896-1300
Yelm Rick Carlile Cell 253-381-6080
Conditioned Floor Area : 3115 Sum of UA for Heating System Sizing 125.5
Sum of All Glazing Areas From Below 362
Glazing to Floor Area Ratio 11.61% 602.7.2 Exception Ratio(not to exceed 1%)�
Exterior poors
Plan Component Door Percent Width Height Glazing Door poor
ID Descri tion Ref. U-factor Glazed Qt. Feet �"�' Feet �"�' Area Area UA
Frnt Fiber lasg��tnsulat�d � �.IEC�� ;'��16Q � '�- � 'k-� , ; 3 �, t 6 �': � � 20.0 3.2
� .��
�w
,;. � ;�,.,
� ,
. z� :
� .�; , ,.,
;
. ��
_ e . _ F ,- � _ - � � ,
�
GaEW` One Exempt Swinging Door<24 Square Feet ' 1 ' ° 2 . . � ., � ;. 17.8
Sum of Glazing Area, Door Area, and UA (do nof include exempt door} �_ 20.0 3.2
Area Weighted U= UA/Area 0.16
Sum of Area and UA for Heating system size only(include exempt door) 37.8 3.2
Vertical Glazing (Windows, Gfazed doors using Exception 602.6#1)
Plan Component Glazing Width Height Glazing
ID Descri tion Ref. U-factor Qt. Feet '"`�' Feet-'"�' Area UA
L&C3 2:GIzVin`��:4�E;�.: $� � � �` "�x�` �°�_ �►FR� C3;34� 2F ,k� �:„� �_ ��. ;� 50.0 47.00
Kifi<:. 2.Gf�,�,Uin'�°L��V���£` v� ,>�� � � ����,= NFRC (�34t�'., 1 �;.;;"�� ,� �� '�� 30.0 10.20
Gc,R 2 GltVit�` �Lc�w�'Si� e�S aCe�SGEX�a�: �1�RC ff:33�=,;� 1 , , ��' �.4 �� ��A�: 48.0 15.84
G�R 2 GI��in i�av��:� . � �� 3 ... ::. �..=' N�RC C}:°34t� � �� �fiF��. ,: ��� �.°: 40.0 13.60
Gr`ft 2 GI��i1 �Lov��f?�����;` � ' N��� �z32��r 2`� �=,`, ��° �`��� �,�,; 12A 3.84
Br� 2 GI�VIn �:�at��> � °��� ���� 1V�FiG �;'34f�;�. 1 f. �„;� ��� t�°� ��M�; 25.0 8.50
; ' , �
Brs° 2 GI��I►ri ��Lp'V�������, � � _�`;� �� ��> ��� Q:�4.t�w. �� ��`�. ���"�._� �� 80A 27.20
Mbr. 2.G����ri �°���:5��,,�:��,��������`������ ,�tF`t�� C�;°34� ;� 2'� 3:�,' ��. : �,��T ��� 24.0 8.16
Mlit'� �F`af2:��h ��(�V��:`:��.�� �r � ��.,��� ���� NF�i`Cx t�z34f�a,�:' 1; � ��'� v.��'; �`,�� �,�:` 4.0 1.36
Loft. �Gtz�rt �F�:ow�`. : NFR� �:�4Q' 2 4..�'� �:.� ��,: 40.0 13.60
Ent' 2 Gt�Vin F.t:c�w.���;� �.: � �:; , ,.� NFRC 0:34�� . 1 ��°a. H � ,� . 8.8 2.98
,� �� � �� � ; a � <
�x_
,.� �`�i. '�'��n��� '� '� € r, � � �� � .
,� � �
.. . . .; ...r „ �. .'�, .:
��� � ,� �_;`
t t �� �cr�n � .
���'
t t` d�,,���:
x
v *.g ,� ; V �' .�°'. .
F *, �.. �p � . . .
t ' .�,f "� . � . .
.: - . .. c,�. : .'. .
� +
.
.� , � �.. . � .. �r,. r � .�;., �
�� � �x �
'�, 'G�'�����.n � 'r' 4 � ��-'� ,�1„� . � . .
`'� � `,,k "' �5��" '..�.`, # �k�, . .
t � � �T �, � . .
-r ,. .. , „ y , .
g
Sum of Area and UA 361.8 122.28
Area Weighted U= UA/Area 0.34
WSEC Prescriptive Worksheet(2010 Edition)
WSUEEPIO-010 Copyright 2010
, dverhead Glazing
Pian Component Glazing Width Height
ID Descri tion Ref. U Qt. Feet �"`h Feet �"�' Area UA
;.
i
� � �
Sum of Area and UA
Area Weighted U=UA/Area
Doube Glazed Garden Windows Section 602.7.2 Exception
Plan Component Width Height
�� Descri tion Qt. Feet '"`" Feet '"0h Area UA
Sum of Area
Sum of Area X 3(This total is automatically included in the glazing area tofa/.)
Glazing UA for Heating System Size Only=Area X 0.63
WSEC Prescriptive Worksheet(2010 Edition)
WSUEEPIO-010 Copyright 2010
, Srmple Heating System Size: Climate Zone 1
Project lnformation Contact lnformation
Plan 3115 Freestone Inc
253 896-1300
Yelm Rick Carlile Cell 253-381-6080
Indoor Design Temperature 70
Outdoor Design Temperature 17
Design Temperature Difference(oT)
�T=indoor-Outdoor Design Temp 53
Conditioned Floor Area 3115
Conditioned Volume 26230
Glazing
Copy Sum of UA from Glazing Schedule 125
Attic U-Factor X Area = UA
R-49 0.027 < 1798 48.5
R-38 Advanced 0.026
�— -�-�
Single Rafter or Joist Vaulted Ceilings
U-Factor X Area = UA
R-38 Vented OA27 � �
Above Grade Walls U-Factor X Area = UA
R-21 0.056 2576 144.3
�
Floors U-Factor X Area = UA
R-30 0.029 178Q 51.6
Below Grade Walls U-Factor X Area - UA
2' Depth Walls 0.042
3.5' Depth Wails 0.041
7`bepth Walls 0.037
�— �—�
Slab Below Grade F-Factor X Len th = UA
2' Depth 0.59
3.5' Depth 0.64
7' Depth p.57
�
Slab on Grade F-Factor X Len th = UA
R-10 2' perimeter 0.54
R-10 Full- Heated 0:55
Sum of UA 370
Envelope Heat Load 19605 Btu/Hour
Sum of UA X oT
Air Leakage Heat Load 15014 Btu/Hour
((Volume X 0.6)X aT)X.018))
Building Design Heat Load 34619 Btu/Hour
Air Leakage+Envelope Heat Loss
Buiiding and Duct Heat Load � 34619 Btu/Hour
If ducts are located in unconditioned space:Sum of Building Heat Loss X 1.15
If ducts are located in conditioned space:Sum of Buiiding Heat Loss X 1
Maximum Heat Equlpment Output 150% 51928 Btu/Hour
Building and Duct Heat Loss X 1.50
WSEC Prescriptive Worksheet(2010 Edition)
WSUEEPIO-010 Copyright 2010
� � �3 � ��, z ��-�, �C �
�S�A�'I��
� �
��.o �ti� R l� F-I �d1/
��TH��
Insulation Certificat�/�lower poor'Te�t I+'o�°x�n
Batts&Blankets Thermai Performance(Attic Application)
When installed in accordance with the manufacturer's The stated thermal resistance(R-value)is provided by installing in accordance with the manufacturer's
recommendations,Knauf batts&blankets will provide instructions,the required number of bags per 1,000 sq.ft.of net azea,at not less than the labeled minimum
the full R-value. thickness.Failure to install both the required number of bags&at least the minimum thickness will resuIt
in lower insulation R-value.
� . R-Value Minimum Thiclmess R-Value Bags/1,000 s .ft. Ivlaximurri Cove�a�e Minimum Weight Minimum Thiclmess ,�,`
To obtain an Installed insulation To obtain an The number of Contents of this bag The Weight/SF of Installed insulation
insulation resistance should not be]ess insulation bags/1,000 SF of ne should not cover more installed insulation should not be less
R-Value of: than: resistance area should not be than: should not be less than: than:
(R-Value)of:
R-38 HD 10.25" R-60 29.7 33.6 SF .952 Ibs. 19.750"
R-38 12.00" R-49 23.5 42.5 SF .7531bs. 16375"
R-30 HD 825" R-44 20.9 47.8 SF .6701bs. 14.875"
R-30 10.00" R-38 17.8 56.2 SF .5691bs 13.000"
R26 9.00" R-30 . 13.6 733 SF .4371bs 10.375"
R-22 6.50" R-26 11.8 85.0 SF 377 lbs 9.125"
R-21 HD 5.50" R-22 9.8 102.2 SF .313 Ibs 7.750"
R-19 6.25"'�`* R-19 8.4 1193 SF .2681bs 6.750"
R-15 HD 3.50" R-13 5.7 175.3 SF .1831bs 4,750"
R-13 3.50" R-11 4.7 210.8 SF .1521bs 4.000"
R-11 3.50" Bag Weight-Nominal 301bs,Minimum 291bs.This product conforms to the performance requirements of ASTM C 764,
R-8 2.50" Type 1,&cancelled Federal Specification HH-1-1030B,Type 1,Blass B.R-Values aze determined in accordance with
**R-18 in a 5.5"cavity.Conforms fo ASTM C 687&C 518."R"means resistance to heat flow.The higher the R-value,the greafer tha insulation power.To get the
C665&Federal Specification HH-1-521F inarked R-value,it is essential that fhe insulation be installed properiy.If you do it yourself,get instructions&follow them.
To achieve labeled R-value,this product must be applied with a pneumatic blowing machine&a corrugated hose with a rninimum.25"intemal corrugation,a minimum length
�f 150 ft.&a diameter of at least 3".Coils in the hose should not be less than 36"in diameter.Acceptable material feed rate is 5-351bs./minute.Recommended feed rate is
15-251bs./minutes.
Builders Insulation Statement. �
3atts and/or blankets have been installed in conformance with the above 2009 W3EC Residential Enerev Comnliance Certificate-�uildin�Air Leakaee
-ecommendations to rovide a thermal resistance of....
R-Value Standar� Building&Test Condition: Comments:
Attic Area R- � R-49 Date: ((>' - (-
' Sloped Ceiling R- R-38 Time
Walls R- R-21 Indoor Temp: 2
Floors(over unheated crawl s ace) R- �3 R-30 Outdoor Tem : ^
Floor Area(s ft) 'Z�j
:ompleted as of: Buildine Air Leakage Tar�et: SLA Less Than 0.00030
istallers Name Print: Test#1-Depress_�Press Pretest Baseline Pressure (Pa)
istaliers Name Sign:
Bld Press.(Pa) Flo�v ing Fan Press.(Pa) Florv(cfin)
ite Address: � � � � ! � '', /�� �� � c
- �/��� w A ���-�p � Post Test Pressure: Fan ModeUSN: S
7 �,' -� ,�/� z,�
Results:SLA(Specific Leakage Area): l�(/C/
ome Builders Signature: Test#2-Depress Press Pretest Saseline Pressure (Pa)
ome Builders Address:
Bldg Press.(Pa) Flov✓Ring Fan Press.(Pa) Flow(cfin)
sulation Contractor: Insulation Norkhwest LLC
Post Test Pressure: Fan MadeUSN:
P.253-846-0121 P.O.Box 732069
Results:SLA(Specific Leakage Area):
F.253-846-8096 Puyallup.WA.98373
�davit: I certify that this Specific Leakage Area is accurate&determined using Blower poor Test Stan d 502.4. ildi Air Leakage Testing.
Technician Name Print: Technician Name Sien:
.��1� c� �`t 2
����L�,�r��
� � � � � � � �
� � NC) RTHWEST
�°nrx��'y
In�ulation Certificate/Blo�vver poor Test Form
Batts&Blankets Thernlal Performance(Attic Application)
When installed in accordai�ce with the mumfachirei's The stated themial resistance(R-value)is provided Uy installing in accordance�vith the inamifacturer's
reconunendations,Knauf batts&blankets will provide instructions,the required number of Uags per 1,000 sq.ft.of net area,at not less thau the labeled minimum
the full R-value.. . - --- --- -tiiickness.Failure to itlstall both the required number o�bags&at least the minimum tl�icla�ess will result .
in lower insulation R-value.
R-Value 11iu�imuni Thickness R-Va1ue 1vlinirnum Thickness
To obtain an Inslalled insulation To obtain an Installed insulation
insulalion resistance should not be less insulalion ����i i,uvu Jt ot net siiouid noe wy�, r.�._ _-,-�_.-- shouid not be less
R-Value of: Uian: resistance area should not be than: should not be less than: dian:
-Value)of:
R-38 HD 1025" R-60 29.7 _ _ 33.6 SP ___ .9521bs. 19.750"
R-33 12.00" R-49 23.5 �}2.5 SI' .7531bs. 16375"
R-30 HD 8.25" R-44 20.9 47.8 SF .6701bs. 14.375"
R-30 10.00" R-38 17.8 56.2 SF .5691bs 13.000"
R26 9.00" R-30 13.6 73.3 SI' .437 lbs 10375"
R-22 6.50" R-26 11.8 35.0 SF .377 Ibs 9125"
R-21 HD 5.50" R-22 9.8 1022 SF 313 lbs 7.750"
R-19 625"'� R-19 8.4 1193 SP 2681bs 6.750"
R-15 HD 3.50" R-13 5.7 175.3 SF .183 Ibs 4.750"
R-13 3.50" R-11 4.7 210.8 SF .1521bs 4.000"
R-11 3.50" Bag Wei�ht-Nominal 301bs,Miuimum 291bs.This product confomzs to tlze performance requirements of ASTM C 764,
R-8 2.50" Type 1,&cancelled Federal Specification HH-1-1030B,Type 1,Blass B.R-Values are determined iu accordance with
�,,,,f r,,,�r„e " �neans resistance to heat flo4v.The hi her the R-value the�eater the insulation ower.To�et the
C665&Federal Specification T�H-1-521P marlced R-value,it is essentiai fliat the insulation be installed properly.ff you do it yourself,get instnictions&follow them.
To achieve labeled R-value,this product nnist be applied with a pneumatic blowing machiue&a comtgated hose with a mininuun.25"internal corrugation,a minimLUn length
of 150 ft.&a diameter of at least 3".Coils in the hose should not be less than 36"in diameter.Acceptable material feed rate is 5-35 Ibs.hninute.Recommended feed rate is
15-25 lbs.hninutes.
Buildeis Insulation 5fatement.
B atts and/or bluikets have been installed in conformance with the above 2009�'SEC Residential Lnerav Compliance Certificate-Buildin�Air Lealt2ee
recommendations to rovide a thermal resistance of....
R-Value Standard Buildin &Test Condition Comments:
Attic.4rea R- R-49 Date: •�lp
Sloped Ceiling R- R-33 Time �jQ
Walls R- R-21 Indoor Temp:
Floors(over uiilieated crawl space) R- R-30 OuYdoor Temp:
I loor Area(sq ft)
Completed as of. 1D•��c'��7 I3uildine Air Leaka�e Tar�et: SLA Less`Than 0.00030
Installers Name Print: 'I'est#1-Depress �1 Press Pretest Baseline Pressure (Pa)
Installers Name Sign:
Bldg Press.(Pa Flotiv Ring Fan Press. a) Plo�v cfi�)
Site Address: �"�33� �2�� I^y E�Y�- 1�� h- � ' ` O
"�� Q�/�H Post Test Pressure: Fan Model/SN: ��J��'�j
�� �J 1 �(
Results:SLA(Specific Leakage Area): •���Z� I �•�37' Af.�
Home Builders Signature: Test#2-Depress Press Prefest Baseline Pressure (Pa)
Home Builders Address:
Bld�Press.(Pa) Flow Rin Fan Press. a Flow cim
Insulation Contracfor: Insulation Northwest LLC
Post Test Pressure: Fan Model/SN:
P.253-840'-0121 P.O.Box 732069
Results:SLA(Specific Leal<age Area):
F.253-846-8096 Puvallup.WA.98373
Affidavit: I certify that this Specific Leakage Area is accurate&detennined using Blower poor Test Standard 502.4.5 Building Air Leakage Testing.
TPChnician Name Print' �� TeCI1111C1211 Nflllle Slall: � V _
U
M �
O
N �
Q �
� � �
� � lf') .�--�
� i L, C
M � � �
� �
Q �
r� � � L � �
N � o U Q'o
� � Z �•V N
� � � � �
� � � � U O >+
� ,� -� (a C.� �
� � �
o� � Z � � � >
� q � � �
� � ��
a� �
� � � � � � �'
�y � �' cmU
� Q �� � � N
� �
'v •,� � � �
� ^7 "L � p �
C
'�Ja--�
� q � � ��
� �- �
� � � � N
� 'a } Q � � a�
�
� � w � w °ci � cn
� � W = �j � � � a Q
> U W c� � Q-� c�
� � Q W � ~ a�o � o � U
� �{ � Z (n � a' C� � Q- O
� z o � � Q � Q � Z .� � �
� � pQ o � o �n � .c n c�
N T �
M W Q p w � M Q J � �
M w N � �— � � ,�
� � � � � N � � U �
�
J c�
� � Q � N
� � L
� O �
� � �
� Z �' � . .
� }, O � O
N ;= (B
}���*��� F � � N � J U � U
C i � � � � Q O `�
� "�'� Q ca � � N � V O
r a� � Z Q � �c � �
W � � � � c`a cn � c
�� � � � � � � � '� �
�'�'`a��'� m O O m � Q c� m