20130215 Permit Pkg 05312013 � City of Yelm Permit No.: 20130215
� Community Development Department Issue Date: 5/31/2013
R (Work must be completed within 180 days)
Building Division
Phone: (360)458-8407
w � " FBX: (360)458-3144
Applicant:
Name: SOUNDBUILT NW LLC Phone: 253-848-0820
Address: PO BOX 73790
PUYALLUP WA 98373
Property Information:
site Address: 9871 DOTSON ST SE 73 Owner: SOUNDBUILT NW LLC
Assessor Parcel No.: 78640107300 Subdivision: TAHOMA TERRA Lot: 73
Contractor Information:
Name: SOUNDBUILT NW LLC Phone:
Address:
PO BOX 73790
PUYALLUP WA 98373
Contractor License No.: Expires: 0/00/0000
Project Information:
Project: NEW RESIDENTIAL BUILDING
Description of Work: LOT 73, PLAN 2385A-9-2
Sq. Ft. per floor: First 1063 Heat Type(Electric, Gas, Other): GAS
Second 1322
Third
Garage 391
Basement
Fees:
Item Contractor Fees
NEW RESIDENTIAL BUILDING SOUNDBUILT NW LLC $16,784.68
MECHANICAL SOUND HEATING&AC $ 84.75
PLUMBING RAINIER VIEW ROOTER $ 125.00
TOTAL FEES: $16,994.43
ApplicanYs Affidavit: OFFICIAL USE ONLY
I certify that I have read and examined the information contained within the application and know the same
to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of #Sets of Prints:
Yelm regulations including those governing zoning and land subdivision,and in addition,all covenants,
easements and restrictions of record. If applying as a contractor, I further certify that I am currently Final Inspection:
registered in the State of Wash� gton.
�
.. �F .31 , �� Date:
Signature Date J' �
By:
Firm
REC#: 00128825 5/31/�2013 9:30 AM
OPER: L'0 TERM: 001
REF#: 16129
TRAN: 33.0000 BUILDING PERMITS
2013U215 16,994.43CR
SOUNqBUILT NW LLC
9871 DOTSON ST SE 73
BI.D-RES1 16,784.68CR
MECH 84.75CR
PL 125.00CR
TRAN: 33.00U0 BUILDING PERMITS
2Q130216 17,409.03CR
SOUNDBUILT NW LI.0
9877 DOTSON ST SE 74
BLD-RFS1 17,182.28CR
MECH 87.75CR
PL 139.00CR
TRAN: 33.0000 BUILDING PERMI�fS
20130217 17,488.91CR
SOUNDBUILT NW LLC
9919 DOTSON ST SE EO
BLD-RES1 17,285.66CR
MECH 78,25CR
PL 125,OOCR
TRAN: 33.0000 BUII.DING PERMITS
20130218 16,575.51CR
SOUNDBUILT NW LLC
992� DOTSON 5T SE 81
BLD-RES1 16,379.26CR
MECH 78.25CR
PL 118.00CR
TI�AN: 33.Oq0U BUILDING PERMTTS
20130219 17,488.91CR
SOUNDBUILT NW LLC
9931 DOT50N ST SE 82
BLD-RES1 17,285.66CR
MECN 78.25CR
PL 125.00CR
TRAN: 33.00(l0 BUILDING PERMITS
20130220 17,139.02CR
SOUNDBUILT NW LLC
10033 DOTSON ST SE 98
BLD-RES1 16,935.77CR
MECH 78,25CR
PL 125,40CR
TRAN: 33.00nq BUILDTNG PEf�MI�fS
20130222 1fi,972,98CR
SOUNDBUTLT NW LLC
9913 DOTSON ST SE 7�
BI�D-RES1 16,776.73CR
MECH 78,25CR
PL 118.00CR
TENDERED: 120,068.79 CHECK
APPLIED: 120,068.79-
CHANGE: � O,OQ
YELM COMMUNITY SCHOOLS
PO BOX 476
YELM WA 98597
Clerk; Croy
Termina1: 1
Receipt: 210121
Manual Receipt;
NSOUNDBUILT
NSOUNDBUILT
SOUND BUILT NW LLC, HOMES
PO BOX 73790
PUYALLUP, WA 98373-0790
5/29/2013 11 :44 AM
qty_�. Item ._.____._�.____�____.__._.�.Price
1 CPF MITIGATION 3015.00
MITIGATION
05-027/LOT 73/9871 DOTSON ST SE;YELM
1 CPF MITIGATION 3015.00
MITIGATION
05/027//LO�� 74/9877 DOTSqN ST SE; YELM
1 CPF MiTIGATIGN 3015.00
MTTIGATION
05/Q27/LOT 79/9y13 DOTSON ST SE;YELM
1 CPF MITTGATIqN 3015,00
MITIGATION
05-027/LOT 80/9919 QOTSON ST SE;YELM
1 CPF MTTIGATION 3015.00
MITIGATION
05-027/LOT 81/9925 DOTSON ST SE;YELM
1 CPF MITIaATION 3015.OU
MITIGATTON
02-027/LOT 8�/9931 DQT50N ST SE;YELM
1 CI'F MITIGATION 3015.�0
MITIGATION
Q5-027/LOT 39/10041 JENSEN DR SE;YELM
1 CPF MTTIGATION 3015.00
MTTIGATIQN
05-02�1/LQT 97/10027 DOTSON ST SE;YELM
Subtotal : 2�120.00
Tax; 0.00
Total: 2412.0.00
Check 24120.00
16097
�01�0� l 5
CITY OF YELM
RESIDENTUIL BUILDINC PERINtT APPIICATION fORM
Project Address: �l�f 7/ �c��s�.� �'Sf. S L Parcel#: �7�G `fC>i O 7.3 GC�
Subdivision: 1 c��.o�er rc, Lot#:� Plan#: ,,�e� �'S� 9-Z Zornng:
�'�LVew Construction ; Re-Model/Re-Roof!Addition Home Occupation Sign
,: Piumbing �� Mechanical -:' Mobile/Manufactured Home Placement _: Other
Project DescriptionfScope of Work: �ur�S 1--rccc �- �.s�{-a��� c�c yc� -S�G�
Project value: .7 S,b Z�. �
Bui4ding Area(sq. ft) 1p Floor/G 2"� Floar�3Z Z Garage 3�� [3eck
Basement Carport Patio„�„�_
#Bedroams y #Bathrooms�� 5 Heating�THER or ELECTRIC (Circie One)
Are there any environmentaily sensitive areas located on the parcei? �G�
If y�s, a completed envi�merttai checiciist must accompany permit applica�on.
; ,� _ , �l. � t.,`, ..
ADDR SS r � EMAIL l�ck.,��;�c,�.,4.��.�.tha�j,c5 �s ,Y,
CITY a w STATE ' ZIP :'� TELEPHi�NE :' 3 ~ �s'a�`-C •'�2
_ _ , ; �}c ,► � - LICENSE#_ �
ADDRESS ' ' EMAIL '�r'_ �.���c ;.��rcr ^ '.(,2.r�c'�
CITY��'tkct ` �1 STATE ° Z! TELEPH}i��; , " " ��7
. , .,:, k��:, t N �,� TElEPH4NE „r�S i' �'-9 � �,� c
ADDRESS = :x 7_�S`�yt? EMAIL I��cLy �' `-c� .�ubc1lt `r�c;�r7��, cc.r�,
CITY �:��,..�►al�y�� STATE � r-1 ZIP `'"1�":iL"� FAX `> ` , � :; ._ � ��
CONTRACT�R'S LICENSE# � r 1 �' EXP DATE r CITY LICENSE#
`se+� ��- �;c w' �i��- TELEPHC�NE 15 3 - 9.�L`�`f C:�,
ADDRESS t �� ` ���r�: EMAIL
CITY �. � � � �_STATE L�.� ZIP 1 s �� � FAX ,�„� � _ �� ,� : �r��
3. _Y
CONTRACTOR'. LICENSE�k "' �►1 i� ' ` Z�'' EXP DATE CITY LICENSE�
_ 'Sc.�:,��._ �, ,,, 4f�c: TELEPNONE �'�.. , , ,5 �
ADORESS ��.�c; 1�' �sr r.` �-.,�,t� �MAIL ,�� ?, 4�..7�- � ���_
CITY � w�yy,�,�,_STATE t.� ZIP t a j s FAX .
CONTRACT R'S LICENSE# •�.: { ` � . T, EXP DATE CITY LICENSE#
�r
Copy of mitiga�an agreement with Yelm Communiry Schools, if applicabie.
�►wsby c�etly t!►�t tM abow IMonnation Fs com�ct and that tM co�structio�on,and tM xcupancy�nd th��of th�
�tbow dMerib�d prop�rty wllf b�in sccordar►��with tM tsws,ruNs a�d rrpuiatfa»of tM Stns M WashlnQto�and th�
City ot YNm.
4,,.�,� �? ��.�
Appllo��M's S�nsturo Date
Ownsr/Cor�rsctor �r's� ontracmr's Agfnt(Pl�asa�circls one.►
A!1 permib sr+�non-transfenbl�and witl expin N w�ork autharizu! by such p�rtnit is not bpun
wilhin 180 days of i�suanc�,ot ft wark is suspsnd�d o�aba�dan�d fo�a p�riod of 1 C�����
�� MAY 15 2013
�
lOS Yttm Avenue Weat (S60)4S
Yelm, WA 98597 (SBO)d38-�1�4 FAX
www.ci.yelm.wa.eia
THOMA TER RA - PH. 2- DI V. �
LOT- 73
, �
���,r �) � r
,
����v �6` � �
���
�10'�16.48' 13' 39.5' 19.51'
urnrnES �
EASEMENT N 89•���45+�w �
I W - ---- -—�.- -- 98.49'
5■., 5 �
� � "�,���. O � DRAINS �
� \ ^ S7EP 10.5 ' PORCH
�] ANK N M �„
� �, �;� �� ra _ �
R� ", C.O. I � N tO
� Z �t: �" � �' 2385A9-2 �l Mi� o"'
� _ { �,
� o�� ^�'DRI VEWAY�`` ELEV.-A rr� I�' z
I � p (ca+smuciror+
� �" ;r� r�j �;+�-�" GARA GE �
`o�t ET..� . , �� �° N01'40'07"E
O NCE ,,I� 57� 8.44
� � , z-<< � „Pr., �
, = 15'Lx5'Wx4b
I G'A3"�--- -- � _ .r- � � __ _ � � ,__ DRYWELL
W �F� BSBL in
N 89'1 4
101.86'
12.5'
10' S7'
22.2'
�o y�o,s `�,J
5 ��c-: S�t�t F� k.��. � ,,{ � �
�� �.ti �-tt
IMPERVIOUS AREA � -7
ROOF= 1913 S.F. �---c-'�-�2-_���j___ __.._�
DR►VEWAY & �'
�_r__.�� ...�..�
SIDEWALK= 450 S.F. �- w,
TOTAL= 2363 S.F. � � �� �� F
LOT S.F.= 4021 � ��„�
NOTES: SCALE: 1"=20'
1. FRONT PORCH FOUNDATION AND STEP
TANK LOCATION SHALL BE STAKED OUT
FOR SET BACK INSPECTION. O �O 2O 4O
2. STEP TANK IN VIOLATION OF THE REQUIRED I� CITY OF YELM
5' MINIMUM SETBACK TO FOUNDATION � THURSTON COUNTY
SHALL BE BACK FILLED WITH CDF.
SOUNDBUILT 9871 Dotson St SE
3. CONNECT PVC ROOF DRAINS TO DRYWELL. HOMES, INC. Yelm, WA 98597
CONTACT INFO P.O. BOX 73790 PARCEL# 78640107300
ANGELA: (253) 848-0820 PUYALLUP, WA 98373
PH: (253) 848-0820
FAX: (253) 539-0514 LOT S.F.=4021 PZ 5/21/13 2.0
_ Pr�.criptive Energy Code Compliance for Singie Family and D apre�H'o��s�n9�Zone 1
Prrsject lnfamafion
Plan 2385
This set of fiorms has been developed to assist permit applicants documenting compliance with the
Washin�ton State Energy Code, (2009 edition). This set is for structures built under the IRC and Iocated
in Climate Zone 1.
The following forms pcovide much of the required documentation for plan review.The detaits noted here
must also be shown on the drawings(WSEC 104.2).
This form is not a substitute for the energy code itself.To obtain a copy of the energy code,
go to the following web address. http://wwH+•energy.wsu.edu/code
Glazing Wall12 Wall•int4 Wall•ext4 Slabb
Glazing U-Factor 9 Vaulted
Area10: Door Ceiling2 3 Above Below Below F1oor5 on
Option U-Factor Ceiling Grade
%of Floor Vertical Overhead" Grade Grade Grade
R-49 or R-21 R-21 R-10
�I 13% 0.34 0.50 0.20 R-38 R'38 Int.'
TB R-10 R-30 2,
Adv.
R-49 or R-2] R-21 R-10
�II 25% 0.32 0.50 0.20 R-38 R-38 Int� ,I,� R-10 R-30 2,
Adv.
R-49 or R_21 R•21 R-10
OIII Unlimited 0.30 0.50 0.20 R-38 R-38 lnt.' Tg R-10 R-30 2,
Adv.
See WSEC table 6-1 for fioMates
Gtazing Schedule Attad�ed to Document
Does not apply. (SEE INSTRUCTIONSj Usina Prescriptive Option III.All glazing and
� doors meet maximum U-factor.Alternate heating size method submitted.
� Option I or II,Glazing to floor area limit(WSEC 602.7.2)
� Area weighted window,skylight or door U-factor(WSEC 602.7.2)
� As part of the heating system sizing calculation (IRC M1401.3&WSEC 503.2.2)
Radiant slab:
[� R-10 foam insulation, continuous with thennal break(WSEC 502.1.4.9)
Chapter 9 Options Tatal of 1 Credit Reauired
O t. O t. Descri tion � p []
1 a Hi h Efficien HVAC E ui ment 1 �
1 b Hi h E�cienc HVAC E ui ment 2 �
1c Hi h Efficienc HVAC E ui ment 3 �
2 Hi h Efficienc HVAC Distribution S stem �
3a Efficient Buildin Envela e 1 �
3b Efflcient Buildin Envelo 2 �
3c Su er-Efficient Buildin Envelo 3 �
4a Air Leaka e Control and Efficient Ventilation �
4b Additional Air Leaka e Control and E�cient Ventilation �
5a EtficientwaterHeatin REC��VF� ❑
5b Hi h Effiecienc Water Heatin �
6 Small Dwellin Unit MAY 1 � 2013 �
7 Lar e Dwellin Unit *1 0 kwh ❑
8 Renewable Electric Ener B� --_� 00
Total Credits
WSEC Prescriptive Worksheet(2010 edition)Zone 1
WSUEEPIO-010 Copyright 2010
,. Glazi�n+�Schedule
Contact lnformation
Project informafion
�'�ian 2385
Conditioned Floor Area 2385 Sum of UA fior Heating System Sizing 116.2
Sum of Ail Glazing Areas From Below 321
Glazing to Fioor Area Ratio 13.45% 602.7.2 Exception Ratio(not to exceed 1%)�
Exteriar poors
Plan Component Door Percent Width Height Glazing Door poor
ID Descri tion Ref. U-factor Giazed Qt. Feet �"�' Feet�"8 Area Area UA
0.200 1 3 6 20.0 4.0
En Door 8 17.8 9.6
Fire Door exem t door 0.�0 1 2 6
One Exempt Swin in Door<24 Square Feet .
Sum of Giazing Area, Door Area, and UA (do nof include exempt door) 37.8 13.6
qrea Weighted U= UA/Area 0.36
Sum of Area ar�d UA for Heating system size only(inclUde exempt door) 37.8 13.6
Vertical Glazing(Windows, Glazed doors using Exception 602.6#1) W�dth Hei ht Glazing
Plan Gomponent Glazing g
Descri tion Ref. U-factor Qt. Feet �"�' Feet'"0h Area UA
�� 10.0 3.20
Powder Rovm 0.320 1 2 5
Gneat Raom 0.320 2 2 6 fi 30.0 9.60
0.320 1 5 6 3Q.0 9.60
Great Room +0 34.2 10.93
Dinin Room 0.320 1 5 6
0.320 1 5 1 5.0 1.60
Dinin Room 37.5 12.00
Dinin Room 0.320 1 7 g 5
�� 0.320 1 5 5 25.0 8.00
Pla room 4.320 1 6 4 s 27.0 8.64
Bedroom 4 0.320 1 4 4 e 18.0 5.76
U r En 0.320 1 4 2 8.0 2.56
U r En 0.320 3 2 2 12.0 3.84
Bedroom 3 Q.320 1 4 4 16.0 5.12
Master Bedroam 0.320 1 6 4 24.0 7.68
���r�� 0.320 1 4 4 16.0 5.12
Bedroom 2 0.320 1 4 4 16.Q 5.12
Utili Raom 0.320 1 2 3 6.0 1.92
�� 0.320 1 2 3 6.0 1.92
Sum of Area and UA 320.7 102.61
Area Weighted U= UA/Area 0.32
WSEC Prescriptive Worksheet(2010 Ed'Rion)
WSUEEP70-010 Copyright 2010
S�m�le Heating Systerr� Size: Ciimate Zone 1
� �Projecf lnformation Contact Information
Pian 2385
indoo�Design Temperature ��
Outdoor Design Temperature 20
Design Temperature Difference(aT)
�T=Indoor-Outdoor Design Temp 50
Conditioned Floor Area 2385
Conditioned Volume 2fl,�4�
Glazing
Copy Sum of UA from Glazing Schedule 116
Attic U-Factor X Area = UA
R-49 0.027 1465 39.6
�R-38 Advanced ,.,� 0.026�
Single Ratter or Joist Vauited Ceilings
U-Factor X Area = UA
R-38 Vented 0.027 � �
Above Grade Walis U-Factor X Area = UA
R-21 0.056 2386 133.6
Floars U-Factor X Area = UA
R-30 0.029 1394 40.4
Below Grade Watis U-Factor X Area = UA
2' Depth Walis 0.042
3.5' Depth Walis 0.041
7' De th Walis 0.037
Slab Below Grade � F-Fa_� X Len th = UA
2' Depth 0.59
3.5' Depth 0.64
7' De th 0.57
�—�^�
Slab on Grade F-Factor X Len th = UA
R-10 2' perimeter 0.54
R-10 Full-Heated 0.55
Sum of UA 330
Envelope Heat Load 16491 Btu/Hour
Sum of UA X OT
Air Leakage Heat Load 11203 Btu/ Hour
((Volume X 0.6)X a�X.018))
Building Design Heat Load 27694 Btu/Hour
Air Leakage+Envelope Heat Loss
Building and Duct Heat Load 1.15 31848 Btu/Hour
If duds are located in unconditioned space:Sum af Buifding Heat Loss X 1.15
If ducts are located in conditioned space:Sum of Building Heat Loss X 1
Maximum Heat Equipment Output 154% 47772 Btu 1 Hour
Building and Dud Heat Loss X 1.50
WSEC Prescriptive Worksheet(2010 Edition)
WSUEEPIO-010 Copyright 2010
D��t tes�i�� Calcutr��c�� (1V�e�► Cor�s�rr�r�io�J
_ House address or lot#: �� � °��..}� ���
Conditioned Floor Area: 2��
Duct tester location: �� j�j�jj'L __
_ Pressure tap location:
Rin�'(if applicable): open 1 2 3
• " �- A# Rough-in (Total Leakage)
Test Method & Test2 Calculated
Stand"aFdl• CFM�• Target
Air Handler Present
<_6 CFMZS per 100 sf of CFA .06 X CFA<_ CFMzS
Air Handler not Present -
.04 X CFA<_ CFM
<_4 CFMu per 100 sf of CFa zs
Post Construction
Test Method & Test2 Calculated
Standardl CFM25 Target
Air Handler Present(Total Leakage) ,pg X CFA<_ � .CFMZS
<_8 CFM�per 100 sf of CFA
= Air Handler Present(Leakage to Exterior} .06 X CFA<_ CFM�
<_6 CFM25 per 100 sf of CFA
1. Test results must comply with one of the Standards options.
2. Test CFM,�must be equal to or less than the calculated targ�t.
� Ai� Lea�a�� tes�i�r� Cmlcul��o� (�l�a,�r��D��� Te���
Standard ��M d Catculated Test Resuft �
50 ,
. • (c�a�CFM50 X 0.055)=( � FA X 144)) =S(.A3
. �
0.0003o s�a 31� . '
�ZZ,.d ;
divided by 3����= Si.A
SLA���`��9!
GIOSSQt�I �
Rough-In: After installation of the compiete air distribution system but before instaUation of insulation and she�t rocfc. AI1���s for
access to all duct seams and connections for re-evaluation of seal integrity ff standard is not met in intitia!test_
Past Constrvction: At or near final inspection. The home must be complete enough to pressurize the home to 25 pa.
To#al Leakag�:�Aggregation of the entire systems duct leakage in a duct test. �
leakage ta Exterior: Aggregation of all duct system lealcs to tt�e exterior of the CFA in a duct test.
CFA: Conditioned floor area
CFi1A,5: Cubic feet per minute of air leakage at 25 pascals of pressure �
�FM�: Cubic feet per minute of air leakage at 50 pascals of pressure �
Pasca!(pa): Unit of pressure �
- SIA: Specific lealcage area � �
t �j,� � � l�i.� � � i � - �i 3/ 7
- � ,'A� i � h' �-� �3.-� �
� .f � '�� �� 7 i '�
il
Duct Leakaae Affidavit
Permit#:
House address or lot number: � [ )� �T�t�c'�f�64 � '��
' City: ��`-� Zip:
Co�rd. Floor Area(ft�): �� o � Source (circle one): Pians Estimated Measured
{:. �
❑ Duct tightness testing is not required for this resi enc� per exceptions listed at the end of this document
Air Handler in canditioned space?� �res no Air Handler present during test? yes � no
Circle Test Method: Leakage to Outside otal Leakage
Maximum duct/eakage:
Post Construcfion,total duct leakage: (floor area x.OS)= CFM@25 Pa
Post Canstruction, leakage to outdoors: (fioor area x.06)= CFM@25 Pa
. , �
Rough-�n,total duct teakage with air handler instailed: (floor area x .06) _�CFM@25 Pa _ �
Rough-in,total duct leakage with air handler not instailed: (flovr area x .04) = CFM@25 Pa
Test Result: / CFM@25Pa .. �
, Ring (circle one if appficabie): Open 1 2 � 3`
Duct Tester Locativn: � Pressure Tap Location: � •
1 car�ifiy that thes� duct lea6cage rates are ac�urate and de#ermined using standard duct testing protocal.
Company Name:�,. ° E' � '�°' ���s Technician: ���.�
Technician Signature�, ,� ' , � Date: 1 Phone Number:���.,���
Washington State Energy Cade rsference:
503.�0.3 Sealing.All ducts,air handiers,fiiter boxes,and building cavities used as ducts shall be sealed.Joints and seam�shali comply ,•,,�
with Section N11601.3 of the Intemational Resrdential Code or 603.9 of the Intemational Mechanical Code. Duct tightness testing shall be
conducted to verify that the ducts are sealed.A signed affidavit documenting the test results shall be provided to ih ,�ri�diction having
authority by the testing agent.When required by the buiiding official,the test shail be conducted in the presence of�partment stafr.
Exc�ptions: 1. Duct tightness test is not required if the air handler and all ducts are located within conditioned spac .
2. Duct testing is not required if the furnace is a nondirect vent bjpe combustion appliance instailed in an uncondiiioned space.
A maximum of six fe�t of connected ductworf<in the unconditioned space is allowed.Ail additional supply and r�tum ducts
. . �..o,-r��:;c�,-:-;ar.•. "_�. _ _— ' . .,.. 71 f� -il.�:l�e�i±l�-� c+� hfno r+coalani on�
7i iai�u�,vJ�u�i��`l"�c�.v�i�ltf(;i�l�``i,C:ACc, �U('.:�OU�SI °L.2 Cvf'.��.ICi:oG�S�:c'�.0 ��18��� °S'9�=:..�. ..� ..,�,..�_C: .,�::.
insulated on the e:derior with R-S insulation for above grade ducts and P.-5 vvater resistant insulation when within a slab or
earth.
U
� �N O
� N �
Q � �
�
� � �
N � � �
� � � �
� � � � � o
� � a�i V�o
� � � � U N
� � � �
� L � U O �
� � � � U �
� � � � � p >
q � � � � �
� °'
�
� � ��
� � � �- � � �
� � � sm �
� � � � � N
O �j .� L /�/1 �
� �� � � �
� �
`IV � � � �
t•�l q v -� � (0
V � � � � N
a •� U �.,� � � o�
� � �
W J ~ � N
r� � � �--� 00 � L i
� � � > d� 0 (� ��
.^� (1� Z Q W p-� �
�
� p�j Z I— rn � � o � U
� � O m � � ,r� � wC� _ -°�� o
O X J � � Z cn co
� � Q J N � LLJ � � t�
� � m } � � � J � �
~ � N � � a--'
� O � � N Q J U L
J
�
N d Q � tn
�
� � t� ~
� Z � �
N � � � � 0 . .
� � (6
����tE c � � � � J � � U
'� w � � � N '�
ka �� Q t0 � � �" O 0
:
� a� � zQ � Y s � �
� L L � � U� (B C
�� � � � � � � � � �
���f�� � m � � m � Q � m