Loading...
20130275 Permit Pkg 07242013 �pF rtH�A� City of Yelm Permit No.: 20130275 � y � � Community Development Department Issue Date: 7/24/2013 (Work must be completed within 180 days) Building Division Phone: (360)458-8407 LM FN�MyT9I� Fax: (360)458-3144 Applicant: Name: SOUNDBUILT NW LLC Phone: 253-848-0820 Address: PO BOX 73790 PUYALLUP WA 98373 Property Information: site Address: 9883 DOTSON ST SE Owner: SOUNBUILT NW LLC Assessor Parcel No.: 78640107500 Subdivision: TAHOMA TERRA Lot: 75 Contractor Information: Name: SOUNDBUILT NW LLC Phone: Address: PO BOX 73790 PUYALLUP WA 98373 Contractor License No.: Expires: 0/00/0000 Project Information: Project: NEW RESIDENTIAL BUILDING Description of Work: LOT 75, PLAN 1732 Sq. Ft. per floor: First 1732 Heat Type(Electric,Gas, Other): GAS Second Third Garage 421 Basement Fees: Item Contractor Fees NEW RESIDENTIAL BUILDING SOUNDBUILT NW LLC $16,235.99 MECHANICAL SOUND HEATING&AC $ 71.75 PLUMBING RAINIER VIEW ROOTER $ 104.00 TOTAL FEES: a 16,411.74 Applicant's Affidavit: OFFICIAL USE ONLY I certify that I have read and examined the information contained within the application and know the same to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of #Sets of Prints: Yelm regulations including those governing zoning and land subdivision,and in addition,all covenants, easements and restrictions of record. If applying as a contractor,I further certify that I am currently Final Inspection: registered in the State of Was � gton. Si nature � i Date 7 '� � r- � Date: Firtn By� Cit af���m�L YELM COMMUNITY SCHOOLS ('36�) 1�;��-� pM PO BOX 476 ��2q�2013 YELM WA 9$597 R�C#: Ot�1341 T ERM: 001 �pE�� 16563 Clerk; Gerber REF#: Terminal; �3.0000 HUIt�[��['NG p��M�T� Rece i pt; 212989 "fRAN: 16,917.3��R Manual Receipt: 201302�i4 S���pgU1LT Nw �-�� NSOUNDBUILT 10�1a9 a�T50N�i���U�G� NSOUNDBUILT g�,p-R�S1 �g,25CR SOUND BUILT NW LLC, HOMES MECH 118.00CR P� BOX 73790 PUYALLUP, WA 98373-0790 pL BUII_aING PERM��' 7/24/2013 11:50 AM TRAN: 33.0000 16,411.74CR 20130275 Q�1.�' ____ Item Price SOUND6UILT NW LLC _- _ �_._.__.--___._— gg83 D0150N1�235 ggC� 1 CPF MITIGATION 12060.00 g�p-RES1 71,75CR MITIGATION MELN 10A.00CR 05-027 Tah Terra - Lots 75, 77, 78 & 94 PL 33.UOOQ ��16�g94.43CR �5 "fRAN: Subtotal: 12060.00 'L0130'l�� Tax; 0.00 SOUNDB�Z�-T N� �LC Total: 12060.00 gg01 qOTSON1�,7g4 68CR Check 6LD-�E51 8A.75CR 16562 12060.00 MECH 125.OQCR pl 33,000� gu�����g 43C��J Change Due: TRAN: 0.00 20130218 SOUNLI��I�� NW �-LC 990� DnTSON16,�64.68CR g�q-�ES1 gq,75CR TNANK YOU MEGH 13g,00CR PL 67 331.92 CHECK TENDEREQ� 67 331 .92- APPLI�D: , _.�-- p�p CHANGE: _ . _ _.. CI7Y OF YELM �/� � ��� RESIDENTWL BUILDING PER�AIT APPLICATION FORM Project Address: ( �b�j ��jY� �, � Par�l#: I d�vf I-DI C���L� Subdivision: �G�Y1_.�C(_;��1'L(.-�ot#:� Plan#: �1�� Zonirtg: �New Construction ❑ Re-Model!Re-Roof/Addition ❑ Home Oocupatior►Sign � Piumbing o Mechanical G Mabile/Manufactured Hame Placement ❑ Other Project DescriptioNScope of Work: ��l'�S-}"Y�.L_L�}� Y�.�i.� 5�1=-- v1.1��-e ✓ Project V81ue: ��v�(� Z�j�. — Building Area(sq. ft) 1� Floor 1�� 2nd Floor Garage � �` Deck Basement Carport Patio (�i�k.�-'j�,cF,c,IL� #Bedrooms� #Bathrooms� Heating: Sl THER or ELECTRlC(Circie One} A�e there any environmentally sensitive areas located on the parcei? Ky+vs, a compieted en�ronrr�ental checictist must actaompany permit application. ,.. . � . ADDR SS �C• � O EMAI 4ft��SUc� u�(.f MryrcS Cty►�► (. ClTY a w STATE ZIP TELEPH NE ��S3-- 848-C g�G n i c LICENSE# ADDRESS " EMAIL�0.e�� � �cr _C�,�NC� CITY r3C�ct STATE 21 TELEPH�IVE - / �� �i 1n.1 TELEPHONE .,2 53- 9 -�b'a a ADDRESS � � x EMAlL � � �o+=+�� ��� �+ncSaCa»-� CITY� A � STATE,�,II ZIP FAX -���- 0 3� CONTRAC OR'S LICENSE�k � EXP DATE � CITY LICENSE# �h�er �cw' ✓ TELEPHONE S - = 9(a ADDRESS � K ?3�70 EMAIL CITY k a c.� STATE L�� ZIP 37 3 FAX �.53- 435- l S CONTRACTOR' LICENSE# i n � D EXP DATE CITY LICENSE� _ ,. , �, N t�c. TELEPHONE �� -- - S ADDRESS �� St � ��c EMAIL :���-S?S-��SS CITY a.� • STATE W ZIP FAX CONTRACT R'S LICENSE# EXP DATE CITY LICENSE# Copy of mitigatian agreement with Yeim Community Schools, if appl+cable. �h�nby c��tN�r thwt t!w sbow InfoRnatbn is eornct and that th�conshuction on,and th�occ�ancy and t!w uq ot tl+a sbow d�sceib�d p►op�rty vritf b�in sc�r�with tM tsrvs�ruNs and npulations o!tta 5tab d Vltashirqton and the City ot YNm. ��?��/ � �le l� Appl nt's nature Date Ovmer t Contracto� s Ap�nt! trsctflr's Agent(Pl�ase cir�le otw.) Alt pent�tbs sro non�ransierabl�and Mriil�xpire if wcrk authortr.sd by such pKmit is not bpun withln 180 days ot issuance,or[!work is suspsnd�d or abandoned �.�����.�� � . � �� ��� � � ���� lOb Yelm Auenue West ' l68�8885__ Yelin,WA 98597 ����j�38=81�/� www.ci.yelm.waas � a : � �.'����8��S�.k�^:..�y i� 5 ����A�,�a� . £`a�' . � � '��' �Y� q � A�� �J°pt� �i_5� ees�b.� , ,A..�an:4 �S nfi�u,� �� _ i}i l ��r�.,l�� � ai� �,�; �,���� � AAn-�¢'!u� �.. �I ' t%ba �r` +�w < s.v+�.= g�, <:+,rqa..wv.a,aur . Y.,.�rth, .. ,<r�'.as u�',z:4«J,:r3 b}�,.y..,.€caaA.� ._., .s .z. .q.s. , n r.%r. .t, .., <.�. t ,r.rr.�r�-, . , _a✓°,zr=s .� -r�� a ,. _e P.. .�� K,..o-a*.�Y@t,�� . ( t O � � � I ''''^^��..�� � � ' j � � .x�, 6 .� 4. 4 � � 1 � f—W- � Q � ` �a;�� �c � p N N i � � � � � Q N � N Cy; �� � '• x Q F-- �, ('`, ,,., � L�, ~ � �'� , t-'° "' N �� � � tl'� Q �dy"� ? °� o �a � w i'�t:�, ...� w �y—� �-- �s^.�i,. � U i � lal � � � J � � � w � �LL.o �w t C� � �" Q �' Y..1 ',.. Q � — O O O� d.' G�� i � � � � -�-� i±� t v a � � � � . cD � � q �Q �� �;i 4 ' � � � � � j ° � t----._..�I o I [] �` O � , s' � � ,,.r� �, � _ i ""'� � � � � Q,4 M.S 75t __________._._.----- ,....__. _._....1 � -°-�_ ...._,_,_._--- -t , i � �,_.,.,. � � � _�-- � } i � , m� o� ', � O � ,� � �' °� N I 1 wo + � ; ' w j �p O � � I ~ X ! C,) `'� WWW� � � i � � a Q��Q ! G��� Z�� i ` I � o � x �� o� ' �S� � � �, °� � �� I `���d .— N �- �.1=� --�Z � Q U�� CD �-tv th r'n.t 0 ! i N N u ln o I � t0 U1 0 0 i � �o j __._.. � i � �W 1.�.1 !-- -� ( � � T J � Q� � Y u- tG- i � i Z �U a �U � I � I Q�m z �,m 4 I _....._ .. � � �L h p (n � p ; � I , � , o o� � � �w o � i ,9'8 l,�-»- i M ,� r J O � "� � , Q d Cr � � � p I � .=ani --. _._ :: "` -i��f;� iv co � � V O 5 Z Q tr °d `° �'.`c�":..,,; xv. ( � � � �t a U� Z �� U � �' ��`C��' ' v1� I } � � .�.��` ' '.'' � i j a z o O � "'p °� o � t S�CC'VE � ' Q f= O� Li � -� Z N I � � JNH�11N3 ,.. � 1N.3W3St�3 r}-o� r� w� a ��-� � � NO1�na15n�oa'�'. � S3tttlllf! ,01 a , � z W w � c� W� r- i____.._ . i � vi° '�-'r N °� �� z � a Q :,. , , ;,. .. , . . .. ",°a . � � , . . � , : . 4,1 ti. ��Z � �n� �p F- W - .�VM 3a15.;._.,::• ':.`" . , j Q � CrtL � U OZ - - - jZ .- N �'`') U Q � - --,_.......r..--*-'--` 821ft� ; f '-t' 1 � i , _ _ � � � NIYY 'lV� .,Z � �y� �J �� NOJl.Ol1 _ ___ 332�1 1332{!5 ; -- — 3r ��-o�-� i 3r �i-�z-g � F�rescriptive Energy Code Compliance for Sirtgle Family and Duplex Housing:Zone 1 � Pro'ect lnfnm�afion Contact In1bm►atlon � L1-1732 This set of forms has been developed to assist permit applicants documenting compliance with the Washington State Energy Code, (2009 edition).This set is for structures built under the IRC and located in Climate Zone 1. The following forms provide much of the required dacumentation for pla� review. The details noted here must also be shown on the drawings(WSEC 104.2). This form is not a substitute for the energy code itself. To obtain a copy of the energy code, go to the following web address. http:J/www.energy.wsu.edu/code Glazing WalllZ Wall•int4 Wall•ext4 Slabb lo, Glazing U-Factor �r 9 2 Vaulted s Oprion �'eS • U-Factor Ceiling Ceilin 3 Above Below Below Floor on %of Floor Vertical Overhead'1 � Grade Grade Grade Grade R-49 or R-21 R-21 R-10 �I 13% 0.34 0.50 0.20 R-38 R-38 �t� ,I,B R-10 R-30 2, Adv. R-49 or R-21 R-21 R-10 0 II 25% 032 0.50 0.20 R-38 R-38 �t� TB R-10 R 30 2, Adv. R-49 or R-21 R•21 R-10 �III Unlimited 0.30 0.50 0.20 R-38 R-38 R-10 R-30 2, Adv. Int.l TB See WSEC table 6-1 for fnoMotes Glazing Schedule Attached to Document ❑ Does not apply. (SEE INSTRUCTIONS)UsinQ Prescriptive Option 111.All glazing and doors meet maximum U-factor.Alternate heating size method submitted. � Option I or II, Glazing to floor area limit(WSEC 602.7.2} � Area weighted window,skylight or door U-factor(WSEC 602.7.2) � As part of the heating system sizing calculation (IRC M1401.3 &WSEC 503.2.2) Radlant alab: ❑ R-10 foam insulation, continuous with thermal break(WSEC 502.1.4.9) Chapter 9 Optiona Total of 1 Credit Rec�uired O t. O t. Descri fion 1a Hi h Efficien HVAC E ui ment 1 1.0 � 1b Hi h Efficienc HVAC E ui ment 2 � 1c Hi h Efficien HVAC E ui ment 3 � 2 Hi h Efficienc HVAC Disfibution S stem � 3a Efficient Buildin Envelo 1 3b Efficient Buildin Envelo 2 � 3c Su r-Eificient Buildin Envefo 3 � 4a Air Leaka e Control and Efficient Ventilat�on ❑ 4b Additional Air Leaka e Control and Efficient Ventilation ❑ 5a Efficient Water Heatin RE C EI V ED p 5b Hi h Effiecien Water Heatin 6 Sma11 DweHin Unit JUN 2 � 2013 � 7 Lar e Dwellin Unit � 8 Renewable Electric Ener �,200 kwh ❑ Total Credits - 1.00 WSEC PrescripNve Worksheet(2010 edition)2one 1 WSUEEP10-010 Copyright 2010 . Glazing Schedule IM�rmation Contact Inibrmatlon L1-1732 Conditioned Fioor Area 1732 Sum of UA for Heating System Sizing 111.5 Sum of Ail Glazing Areas From Below 306 Giazing to Fioor Area Ratio 17.67°/a 602.7.2 Exception Ratio (not to exceed 1%)C� Erterior poors Plan Component Door Percent Width Height Giazing Door poor ID Descri tion Ref. U-factor Glazed Qt. Feet �`�' Feet �"�' Area Area UA En Door 0.200 1 3 6 8 20.0 4.0 Fire Door exem t door 0.540 1 2 8 6 ° 17.8 9.6 One Exem Swin In Door<24 Square Feet Sum of G/azing Area, Door Area, and UA (do not include exempt door) 37.8 13.6 Area Weighted U=UA/Area 0•� Sum of Arisa and UA for Heating system siza only(include exempf door) 37.8 13.6 Verticai Glazing(Windows,Glazed doora using Euception 602.6#1) Plan Component Glazing Width Height Glazing ID Descri tion Ref. U-factor Qt. Feet �"`�' Feet �"�' Area UA ENTRY 0.320 1 1 8 6 9.0 2.88 ENTRY 0.320 1 2 6 12.0 3.84 BEDROOM 3 0.320 1 6 6 36.0 11.52 BEDROOAA 2 0.320 1 5 4 8 22.5 7.20 KITCHEN 0.320 1 4 4 16.0 5.12 DINING 0.320 1 6 8 48.0 15.36 GREAT ROOM 0.320 2 5 6 60.0 19.20 MASTER BEDROOM 0.320 2 6 5 60.0 19.20 MASTER BEDROOM 0.320 2 2 5 20.0 6.40 MASTER BATH 0.320 1 5 4 8 22.5 7.20 Sum of Area and UA 306.0 97.92 Area Weighted U= UA/Area 0.32 WSEC Prescriptive Worksheet(2010 Edition) WSUEEPIO-010 Copyright 2010 Overhead Glazing Pian Component Giazing Width Height ID Descri tion Ref. U Qt. Feet �"`r' Feet �"`�' Area UA Sum of Area and UA Area Weighted t!=UA/Area Doube Giazed Garden VIlindows Section 602.T.2 Exception Plan Component Width Height ID Descri tion Qt. Feet �"d' Feet �"a' Area UA Sum of Area Sum of Area X 3(This total is automatically included in the glazing area total.) Gtazing UA for Heating System Size Only=Ar�sa X 0.63 WSEC Presaiptive Woricaheet(2010 Edition) WSIJEEPIO-010 Copyright 2010 Simple Heating System Size: Climate Zone 1 P ' Infom►ation Contact lnformatfon L�1-1732 Indoor Design Temperature 70 Dutdoor Design Temperature 19 Design Temperature Difference(oT) GT=indoor-Outdoor Design Temp 51 Conditioned Floor Area 1732 Conditioned Volume 17,267 Glazing Copy Sum of UA from Giazing Schedule 112 Attic U-Factor X Area = UA R-49 0.027 1732 46.8 R-38 Advanced 0.026 Single Rafter or Joist Vauited Ceilings U-Factor X Area � UA R-38 Vented 0.027 � � Above Grade Walis U-Factor X Area m UA R-21 0.056 1532 85.8 Floors U-Factor X Area = UA R-30 0.029 1732 50.2 Below Grade Walls U-Factor X Area = UA 2' Depth Wails 0.042 3.5'Depth Walls 0.041 7� tp h Wall�_� Slab Below Grade F-Factor X Len th = UA 2' Depth 0.59 3.5' Depth 0.64 7�—� o� Slab on Grade F-Factor X Len th - UA R-10 2' perimeter 0.54 R-10 Fuil-Heated 0.55 Sum of UA 2� Envelope Heat Load 15010 Btu/Hour Sum of UA X OT Air Leakage Heat Load 9511 Btu/Hour ((Volume x o.$)x aT)x.01 s)) Building Design Heat Load 24520 Btu/Hour Air Leakage+Envelope Heat Loss Buiidfng and Duct Heat Load 1.15 28198 Btu/Hour If ducts are located in uncondidoned space:Sum of Building Heat Loas X 1.15 If ducts are tocated in conditioned space:Sum of Building Heat Loss X 1 Maxlmum Heat Equipment Output 150% 42297 Btu/Hour Building and Duct Heat Loss X 1.50 WSEC Prescriptive Worksheet(2010 Edition) WSUEEPIO-010 Copyright 2010 �=�,rrR siC.y'�r�7 -*;@s' v�.�'r.g�'.7E+ � �<.T .—�`,a.;.w A � , m, . ° ""'=�-� ..:��a� �'^�� 4 s €. -r �.ez�,��" L o `� r�,m�e�� -''�r;7 �`" ,i� `4'^x,'�° o't °�it� � E�. � � � b. . _ ., s._ � � _;� r _ . ....,w,.. • �,..x. �.-- .+,. r+,� , w .�. . ..,.�.� .� ,.,;.,�, e....,�.�... ,=d a .: . .,.,�.-,-, ...<�, � _.,. ..w. , ; . . . ... ....... . . .... . . . ... ..... ... . ... � � � � �' ( � l�/1 E .� � � � t�i7 � . � � rJ � � t � ( �1 �t c� �v � : � � � � �J � � �` � �� �I . (^�- --, N �'' ?, ' C3 � � C � � � � i �-- j � �-- �, t�- .` �. �, ._ N i � � � � `:i �� `� � � � �� -.�,.i � � •�' � � c� j "' � � �,-� � p., � � c� i — (� � C3'� ,�.' - • ,� �° ,yj ff, � ` v�i ' � � i ,� � ' � -�� � � �n�.. ��, �p - � � � � � � .� �� � � i � �---- � :,� _ Y�r � � � ± � � �' � � � ' � W °� a�*X'�#� _._m._�____-- ; � �., � � � � ��_ , ._ �_�u.�. ( � � �"� i � � 3 � � � � ; i � , � E � � � t ; � � r � � , � ` t �� � �� � ` � � �� F-- � r � � � ,� � �� f �� ; j L�„) ��41W� � � � ��� � � ��j� ' ; >` � � £' ; � � � °s °,�p Q�� � �,'1 F- v� c�� zw {?d v� Q � ,x �r;� � , ��`� ' .- r+1 ,Q �p� � ° . � ��` i � N 1 I �.C3 � { � ( � P � � � i LJ � �� , , f Q {Sl � Y � '��" � � �� � ��, � � � ! I �� d � F- '4 � � f � ,� (li� � W II] � I � , � � � C1� � h �W � Q _�C� �� I ' : ��V) � � � l� � ; .. : � p` � � �� � � Q ( I � ; i �- �e^� r� � �,. � ` ,i r ,' � �„ CS7 ��.! F � Q ,�r ��� � � � � � � � � �� � � r � �� C�.�� Xin� L�L � I � � � � o` Q � � ��t,.: �` --� � c�w i � �tlN3 11�3YV3S1�`� -f °; 4-a"' C�1 CJ F- t�.J.�E� �� ""°° "..' ( "`_ Ii�ffi�lSt�XJ� � �u�u.1?�Lfl ,(}1 � ;Z a � 4J LY_ G3 4J � i- _..___._ �i {?2! } .,G7 ,,C tl CWl � � � }. s'Q ,�.�. �� Uf tf1� �` W�j� G?� � �j YM 3t]� � � CL' lt. "�` � � � �� N M'1 Q � • •....�.___„_._._.� 8?�tt3 � � -,��;,��( ,S'j� �,�l��c`� q _ya�t����;�," N�►� -,�� .� �.r.w�. ��� ���s �r ��—e—� '�S` �1 S l�l C�.�1 C�Q �r ��-z-a 3 ,.� �f` c 1~t}t-1 I 3t' �t-5�-� i # � , - � . , � , ,�: ' �' Duct Leakage Affidavit (New Construction) Permit#: v^'`C� �� G '� 7�5 House address or lot number: �. � `��t-��/1n� 1...� � , City: �I�C�I� Zip: Cond. Fioor Area(ft2): � 7 �J 2— Source(circle one): Plans Estimated Measured ❑ Duct tightness testing is not required.The total leakage test is not required for ducts and air handlers located entirely within the building thermal envelope. Ducts located in crawl spaces do not qualify for this exception. Air Handler in conditioned space? ❑ yes�no Air Handler present during test?�yes❑ no Circle Test Method: Leakage to Outside Total Leakage Maximum ductJeakage: Post Construction,total duct leakage: (floor area x.04)= CFM@25 Pa Post Construction, leakage to outdoors: (floor area x.04)= CFM@25 Pa Rough-In,total duct leakage with air handler installed: (floor area x .04)_ !I�! CFM@25 Pa Rough-In,total duct leakage with air handler not installed: (floor area x.03) = CFM@25 Pa Test Result: �� CFM@25Pa Ring (circle one if applicable): Open 1 2 3 Duct Tester Location: � Pressure Tap Location: I certify that these duct leakage rates are accurate and determined using standard duct testing protocol. Company Name:�,�� �--�T�,.�°�"' f-t�1� Technician: ��1� � Technician Signature• � Date: � �2�" ( ' � � Phone Number: � I����� ``r. D��t t�sti�� Ca1�t�1�#�� (1��� Cv�s�ru�i��� . House address or lot#: o,� -�,�,,,` �.,_ -7 Conditioned FioorArea: 1-Z � � : Duct tester Iocation: � _ Pressure tap location: �� Ring (if applicable): open 1 ' 2 3 � � ,�.� •� - At Rough-i� (Tc�al Leakage) Test Method & Test� � Calcutate� Sta nd"aFCI? CFM�° �l'arget Air Handler Present � ' .06 X CFA<_ CFM � <_6 CFM�per 100 sF of CFA 75 Air Handler not Present � � <_4 C�M�per 100 sf of CFA . .04 X CFA�<_ CFM,S � Pas�Co�s��uc#�on � � Te� Metfiod & �Test2 Ca1culat�d � Sta ndardl CFMu Ta rgeL Air Handter Present(Total�Leakage} ,pg X CFA<_ ' CFUl� <_8 CFiUI�per 100 sf af CFA � . . Air Nandler Pres2ttt(l:eakaga ta Exterior} ,p6 X CFA< CFM� � <_6 CFM�per 100 sf of CFA - - 1. Test results must c�mply wrth one af the Standards options. 2. Test CFM�must be e�uai to or less than the calcufaLe�targa�. • � � � ���L������ t�s���� C�������� �������[���� �e3�� Tested S�andard � � Ca}cula�ed Tes� R�=�1� � � � C�Msa , . � (t_____��►�5o n�.�s��= 73���>ej ,�, a�y, � , � � �.n:n�� ��� i��_ ! �. _ .� i ' , �- � ��� ' i j ❑;�/lC'.r' 'v��- _ �_ 1 ��..! . � , � y 1 ,� W�-�.��i ���355L7,� � +�1C�7E°,'7-�P1: Aii.2t ITiSi.'c����:on of the complat�217 G�l�7i'�l.TLIOR S/�6Ti'}�glt'S)2=pf2 li]S'e��csIGPI Oi IS15's:�2:70i1 'aiiGi Sii2°:rCC�.;. r�i='r15 i'u' 2CC°SS t0 c�� C�iIS�Sc�i'i15 2�G� C�f1�lE�3Gi15 fOf��-2`l���.IcUa�71 Oi 52�1 l71T��i 7T`/Ci S2;l�ct'u f5 PCti t'ilE?1P iliLi�lc3 2��;_ F��'s�.".3';3i.T',]L'iL'�i: �+�cr na=_r fin�� 1�15r2�10T1. 3 i�2�'1�T�1°ITIi!S i��CCt"i1��°?2 c1�i1�i'?6D��c5:1:PiZ°I:lc 7''1^J?7!v�'D�� yv. !CI3j 7.s??(��; ,4C�i 2��tlOt1 Oi the entir_syr�rns duct le=_;�ag�lp��L'�t°S. � L�3�Ca59�I7�X:'Y10�; A��?��2i.1GP1 01 aJ�GiISCL��2i�1 �2c�5�0��7��xtericr o��i12�y.;S I�l a C�iL1C�t��t. ��f1: Conditioned fioor a�ea , �-i�it�: Cubic ftie�p�r ninute a3 ai�Iea�a��a=?5�a�cals o"p���-:.;r� _ ��i�l;�: Cubic feet pa��inui_�i air isa�zg=_at 5o F�s�ais o�p�e�=ure ��=tia� ��a): Uri�ef prsssuTe _ — Si�: SQecific 18alcage area