2385 Energy Calcs Prescriptive Energy Code Compliance for Climate Zones 6, 5 and Marine 4 ProjF ct Information Contact Information L2M-2385 This project will use the requirements of the Prescriptive Path below and incorporate the the minimum values listed. In addition, based on the size of the structure, the appropriate number of additional credits are checked as chosen by the permit applicant. Authorized Representative Date Climate Zone ;�� ar ine 4 6 R-Valu U-Factor' R-Value' U-Factory Fenestration U Factorb n/a 0.30 n/a 0.30 Skylight U-Factor n/a 0.50 n/a 0.50 Glazed Fenestration SHGCbe n/a n/a n/a . Ceiling 49' 0.026 49 0.02 6 02 Wood Frame Wall9 k.1 21 int 0.056 21+5ci 0.044 Mass Wall R-Value' 21/21h 0.056 21+5h 0.044 Floor 309 0.029 301 0.029 Below Grade Wall,k 10/15/21 int+TB 0.042 10/15/21 int+TB 0.042 Slab`' R-Value & Depth 10,2 ft n/a 10, O ft n/a *Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2. Each dwelling unit in one and two-family dwellings and townhouses, as defined in Section 101.2 of the International Residential Code shall comply with sufficient options from Table R406.2 so as to achieve the following minimum number of credits: ❑1. Small Dwelling Unit: 0.5 points Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration area. Additions to existing building that are less than 750 square feet of heated floor area. [�]2. Medium Dwelling Unit: 1.5 points All dwelling units that are not included in#1 or#3, including additions over 750 square feet. ❑3. Large Dwelling Unit: 2.5 points Dwelling units exceeding 5000 square feet of conditioned floor area. Table R406.2 Summary Option Description Credit(s) la Efficient Building Envelope 1a 0.5 ❑ 11b Efficient Building Envelope 1b 1.0 ❑ 1c Efficient Building Envelope 1c 2.0 ❑ 2a Air Leakage Control and Efficient Ventilation 2a 0.5 ❑ 2b Air Leakage Control and Efficient Ventilation 21b 1.0 ❑ 2c Air Leakage Control and Efficient Ventilation 2c 1.5 ❑ 3a High Efficiency HVAC 3a 0.5 ❑ 3b High Efficiency HVAC 3b 1.0 ❑ 3c High Efficiency HVAC 3c 2.0 ❑ 3d High Efficiency HVAC 3d 1.0 ❑ 4 High Efficiency HVAC Distribution System 1.0 ❑ 5a Efficient Water Heating 0.5 ❑ 5b Efficient Water Heating 1.5 ❑, 1.5 6 Renewable Electric Energy 0.5 +77771-120OTwh 0.0 1.50 Total Credits *Please refer to Table R406.2 for complete option descriptions htt www.ener .wsu.edu Documents 2012%2ORes%2OEner df Glazing Schedule Project Information Contact Information L2M-2385 R402.3.3 Exception (15 sq ft. max.) 15 Vertical Glazing (Windows and glazed doors) Plan Component Glazing Width Height Glazing ID Description Ref. U-factor Qt. Feet in Feet n Area UA Powder Room 0.30 1 2 5 10.0 3.00 Great Room 0.30 2 2 a 6 30.0 9.00 Great Room 0.30 1 5 6 30.0 9.00 0.30 1 6 6 s 40.0 12.00 Dining Room Dining Room 0.30 1 6 1 6.0 1.80 Dining Room 0.30 1 8 5 40.0 12.00 Kitchen 0.30 1 3 3 s 10.5 3.15 Den 0.30 1 5 5 25.0 7.50 Playroom 0.30 1 6 4 ° 24.0 7.20 Bedroom 4 0.30 1 4 4 ° 16.0 4.80 Upper Ent 0.30 1 4 2 8.0 2.40 Upper Entry 0.30 3 2 2 12.0 3.60 Bedroom 3 0.30 1 4 4 16.0 4.80 Master Bedroom 0.30 1 6 4 24.0 7.20 Master Bath 0.30 1 4 4 16.0 4.80 Bedroom 2 0.30 1 4 4 16.0 4.80 Utility Room 0.30 1 2 3 6.0 1.80 Bath 0.30 1 2 3 6.0 1.80 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 o.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.01 0.00 o. 0 00 o 0 0.0 &00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 Sum of Area and UA 335.5 100.65 Area Weighted U = UA/Area 0.30 Simple Heating System Size: Washington State This heating system sizing calculator is based on the Prescriptive Requirements of the 2012 Washington State Energy Code(WSEC)and ACCA Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling loads. The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC. Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop-down options, please call the WSU Energy Extension Program at(360)956-2042 for assistance. Project Information Contact Information L2M-2385 Heating System Type: O Forced Air Furnace 0 Heat Pump To see detailed instructions for each section, place your cursor on the word'Instructions". Design Temperature Instructions ..__ _ - ---- Design Temperature Difference(DT) 41 i acoma CO _ AT=Indoor(70 degrees)-Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area(sq ft) F 2,385 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height(ft) 8.5 20,273 Glazing and Doors U-Factor X Area = UA Instructions 0.30 336 100.65 Insulation Attic U-Factor X Area = UA _._ — -- �� 0.026 1,4&5 38.09 Instructions R-49 ......,..J Single Rafter or Joist Vaulted Ceilings U-Factor Area UA InstructionsSelect-R-Vaiii e-- No selection Above Grade Walls(sec Figure 1) U-Factor Area UA Instructions ''° 0.056 2,386 133.02 R•21 Floors U-Factor Area UA Instructions 0,029 1,394 40.43 R-30 Below Grade Walls(see Figure 1) U-Factor Area UA Instructions No selection --- Select R value Slab Below Grade(see Figure 1) F-Factor Length UA Instruc?ions -.—_— _ ....--- No selection Jl --- Select conditioning l ---mss--c m-- Slab on Grade(see Figure 1) F-Factor Len th UA Instruc tions -ec ___ NO selection Select R-Value � Location of Ducts Instructions ----��_. Duct Leakage Coefficient Unto fined Space _ �� I 1 10 Sum of UA 312.78 Envelope Heat Load 12,824 Btu/Hour Figure 1. Sum ofUAXAT Air Leakage Heat Load 8,977 Btu/Hour Volume X 0 6 X AT X.018 Abo„Q rr,de Building Design Heat Load 21,801 Btu/Hour •:. Air Leakage*Envelope Heat Loss BU ilding and Duct Heat Load 23,981 Btu/Hour Ducts in unconditioned space.Sum of Building Heat Loss X 1.10 Ducts in conditioned space Sum of Building Heat Loss X f Maximum Heat Equipment Output 33,573 Btu/Hour Building and Duct Heat Loss X 1.40 for Forced Air Furnace Building and Duct Heat Loss X 1.25 for Heat Pump (07/01/13)