Loading...
20130311 Permit Pkg 09042013 woF''HEp� City of Yelm Permit No.: 20130311 o � q � Community Development Department Issue Date: 9/04l2013 (Work must be compieted within 180 days) Building Division Phone: (360)458-8407 L ""`"'"`_°" Fax: (360)458-3144 Applicant: Name: FREESTONE CHERRY MEADOWS LLC Phone: 253-896-1300 Address: 6820 20TH ST E STE A FIFE WA 98424 Property Information: Site Address: 15461 CHAD DR SE Owner: FREESTONE CHERRY MEADOWS LLC Assessor Parcel No.: 41610018000 Subdivision: CHERRY MEADOWS Lot: 180 Contractor Information: Name: FREESTONE CHERRY MEADOWS LLC Phone: 253-896-1300 Address: RICK CARLILE 6820 20TH ST E STE A FIFE WA 98424 Contractor License No.: FREESI'969NZ Expires: 1/24/2011 Project Information: Project: NEW RESIDENTIAL BUILDING Description of Work: LOT 180, PLAN 2758B Sq. Ft per floor: First 1248 Heat Type (Electric, Gas, Other): GAS Second 1516 Third Garage 400 Basement Fees: Item Contractor Fees NEW RESIDENTIAL BUILDING FREESTONE CHERRY MEADOWS LLC $16,848.43 MECHANICAL KLIEMANN BROS. $ 78.25 PLUMBING PELTRAM PLUMBING $ 118.00 TOTAL FEES: S 17,044.68 ApplicanYs Affidavit: OFFICIAL USE ONLY I certify that I have read and examined the information contained within the application and know the same to be true and . I also certify that the proposed structure is in conformity with all applicable City of #Sets of Prints: Yelm regula' ns in uding those governing zoning an land s division,and in addition,all covenants, easement nd re ridions of record_If app ing as a ontra or, I further certify that I am currently Final lnspection: regis re in ate of Wash' n. � Signatur , Date Date: Firm By� i Cit� of Y�lm (36 } 458-84U2 kEC#: OU137523 9/04/2013 2:5U F�M OPER: CO TERM: 001 REF#; 2601 TRAN; 33,0000 BUILDING PE�MITS 2.0130301 17,051 .18CR FREESTONE CHERRY h1EADOWS L.LC 15467 CHAQ DR SE 6LD-RCS1 16,848.43CR MECH 84.75CR PL 118.00CR TRAN: 33.0000 BUILDING PERMfTS 10130311 17,044,68CR FREESTONE CHERRY MEADOWS LI�G 15461 CHAD DR SE BLD-RES1 16,848,43CR MECH 78.25CR PL 118.00CR TRAN; 33.0000 BUILDTNG PERMI�fS 2C1130312 17,328.OJCR FREESTONE CNEkRY MEAD04VS LLC 15455 CHAD DR SE BI.D-RES1 17,110,84CR MECH 78,25CR PL 139.00CR TENDERED, 51 ,423.95 GNECK APPLIEO: 51,423.9�- CHANGE: 0.00 YELM COMMUNITY SCHOOLS YELM WA 98597 Clerk: �roy Terminal� Receipt: � 215726 Manual Receipt; NFREESTONE 6820S20TH�StLE SUITE A FIFE, WA 98424 9/4/Z013 2:46 PM �Qt Item `------------- �-v._______.._..______ Price � CPF MItIGATION MITIGATION 3015,00 03-021/LpT �7g��5467 CHAD DR SE;YELM r CPF MITIGATION MITIGATION 3015.00 03-021/LQT 180/15461 CHAD DR SE;YELM 1 CPF MTTIGATION MItIGATION 3015.00 03-021/LOT 181/15455 CHAD QR SE;YELM Subtotal; 9045.Op tax: 0.00 tatal; 9045.00 Check 9045.00 2602 Change Due; a Q� THANK YOU 6.5' �2� 20' 17' �� �.�..-�--•--- ( � s2.oa� SCALE:1"-20' � ,eo �a, � � — 3 a cY� � � DRYWELL� fn N ZO X 92 ! FRONT PORGN � COV PATIQ � ;� FOUN�ATiON AND � � � r I � STEP TANK L�CATION — — — — SHALL BE STAKED I 39 ! OUT �QR SET BACK � � arvs��c�r�orv. ° � 275$ B R�V � � 51"EP TANK � � ! DlAG 64.31' t ° EXCAVATION IN " VIOLATION OF THE � � � w 4 � REQU(RED 5'MINIMUM s.5�I ss� s. � SET BACK TO FOUNQATlON S�1ALL BE s•.,o.I �, 2 eAR f I BACK�D F'iLLED WIl"H �.o. t8.5' GARAGE � I CDF. � � ;� COV.PORCtt { � e � a 2a.5' q § ...... — _ — � NO 5`EAVE ~ S..a- � CONC. ENCROACNMENT ��r=^N�- DRlVE �' THIS L(�T s-,o- e•.7•-' „.,� � � / E � CC}NNECT 4" PVC N / � N ROOF DRAINS TQ �r�' � � � �o'UTILI3Y EStvIT DRYWELL s �UvQ f u C�. ��L�Jl.(z 52.40 w 0 APf'RdXIMATE-- � 2a' �� �URB 1 GUTT�R N �OCATIOFV OF STREET 7REE � GHAD DRI V� 5E� � ����6�C:��,J�L� ----:-�-____.�..__. l . . , � -______�� .��...,. � _! _ .�:__�.._,.3. � � ... �..;��?,,v,�.�'�,�� d � _._ .. � _ . _. ,...._._�.. ���.� � .�l.�N � � �I?�3 c���,��. ... �. - - LCJT 180 - GHERRY MEADC� �y S PARCEL #: 416100 180 00 � pat�: oW�,er: �reestone 06 / 25 /13 Gherr� Meadows LLG Lo� 5fze� Pro�Ject Addre�5: 6820 20th 5t. E Svite A �Ife, WA a8424 5,240 S�. Ft. 1546'f CHAD DRIVE SE 2s�-ea6-i�oo ��30 31I CITY OF YELM RESIDENTIAL BUILDING PERMIT APPLICATION FORM � Project Address: � ��". c�� Parcel#: ''G'��(vCl �,�0 Q O Subdivision: �ot#:�_ plan#: 17 Zoning: �Q New Construction ❑ Re-Model/Re-Roof/Addition ❑ Home Occupation Sign � Plumbing ❑ Mechanical ❑ Mobile/Manufactured Hom lacement ❑ Other Project DescriptionlScope of Work: � ` Q Pro)ect va�ue: 3 ` Building Area (sq. ft) 1"Floor�o�`�'0 2nd Floor��v_ Garage � Basement � Carport — �o� #Bedrooms� #Bathroom�., Heating:�OTHER or ELECTRIC (Circle One) Are there any environmentally sensitive areas located on the parcel? �v /fyes, a compieted environmental checklist must accompany permit application. BUtLDING'OWNER NAM�: � C, �� ADDRE S O EMAIL , .C� C��' � STATE„J�_ZIP TELEPHONE (o- �p ARCHfTECT/ENGINEEI� LICENSE# ADDRESS a5 - EMAIL�_qr �q�q� n CITY Rp�.h¢.� STATE ZIP ► TELEPHONE GENERA�CONTRACTOf� e� TELEPHONE__ � = ADDRESS EMAIL � CITY�c' STATE IP FAX �o2+,-ri� gq�-O�e� — CONTRACTOR'S LICENSE# E 2 EXP DATE � CITY LICENSE# PLUMBING CONTRACTOF� e ��H ADDR SS LEPHONE \- ( CiTY EMAIL STAT Z 0 l FAX (aS�, 9 l -9� CONTRACTOR'S LICENSE# O EXP DATE CiTY LICENSE# � �O MECHANICAL CONTRAGTOR • Ic TELEPHONE a6 5 -O ADDRESS 0 `� EMAIL CITY_i�ry�q.. STATE ZIP FqX ( CONTRACTOR'S LICENSE#kI,TEI�lF�4�0 1 Rr EXP DATE� CITY LICENSE# Co � a'7 201�{ py of mitigation agreement with Yelm Community Schools, if applicable. �hereby certity that the above informatlon Is correct and that the construction on,and the occupancy and the use of the above ed property wf11 be In accordance witN the laws,rules and regulatlons of the State ot Waahington and tha ty Ye m. a ,�, Appl(cant's Signatur Date ; �' � A Owner/Contractor/Owner's Agent/ ontractor's Agent(Please circie one.) � � �-� All permits are non-transferable and will expire if work authorized by such permit Is not begun within 180 days of issuance, or if work is suspended or abandoned for a per�od nf, ���, ��'�""�.��T�� � � �l�N 2 7 2013 � 105 Yelm Auenue Weat ' Yelm, WA 98597 (,�8�45R.RA_44 www.ct.yelm.ma.ua (360)458-3144FAX Prescriptive Energy Code Compliance for Single Family and Duplex Housing: Zone 1 Project mformation Contact Infomration Plan 2758 Freestone Companies 6820 20th st E Yefm Fife WA 98424 253-896-1300 Rick Carlile 253-381-6080 This set of forms has been developed to assist permit applicants documenting compliance with the Washington State Ene�gy Code, (2009 edition�. This set is for structures built under the IRC and located in Climate Zone 1. The foi�owing forms provide much of the required documentation for plan review. The details noted here must aiso be shown on the drawings (WSEC 104.2). This form is not a substitute for the energy code itself. To obtain a copy of the energy code, go to the following web address. http://www.energy.wsu.edu/code Glazing �o Glazing U-Factor poor 9 Vaulted Wall�Z Wall• int4 Wall• eat'� Slabb Option Area : CeilingZ 3 Above Below Below Floors on %ofFloor Vertical Overhead11 U-Factor Ceiling Grade Grade Grade Grade R-49 or R-21 OO I 13% 0.34 0.50 0.20 R-38 R-38 Int.� R gl R-10 R-30 R2�0 Adv. R-49 or R_21 R-21 R-10 O II 25% 0.32 O.SQ 0.20 R-38 R-38 Int.� TB R-10 R-30 2� Adv. R-49 or R-21 R-21 R-IO O III Unlimited 0.30 0.50 0.20 R-38 R-38 Int.� TB R-10 R-30 2, Adv. See WSEC fab/e 6-1 forfootnotes Glazing Schedule Attached to Document � Does not apply. (SEE INSTRUCTIONS) Usin� Prescriptive Oqtion III.All glazing and doors meet maximum U-factor.Alternate heating size method submitted. 0 Option I or II,Glazing to floor area limit (WSEC 60ZJ.2) � Area weighted window,skylight or door U-factor(WSEC 602.7,2) � As part of the heating system sizing calculation (IRC M14013 & WSEC 503.2.2) Radiant sfab: ❑ R-10 foam insulation, continuous with thermal break (WSEC 502.1.4.9) Chapter 9 Options Total of 1 Credit Required Opt. Opt. Deseription 1a Hi h Efficienc HVAC Equipment 1 1.0 � 1b High Efficiency HVAC Equipment 2 1c High Efficiency HVAC Equipment 3 2 High Efficienc HVAC Distribution S stem 3a Efficient Buildin Envelope 1 3b Efficient Buildin Envelope 2 3c Super-Efficient Buildin Envelope 3 4a Air Leaka e Control and Efficient Ventilation 4b Additional Air Leaka e Control and Efficient Ventilation 5a Efficient Water Heatin , ��, d��j�,� 5b Hi h Effiecienc Water Heatin E 6 Small Dwellin Unit � ��N � �' �Q�� 7 Lar e Dwelling Unit 8 Renewable Electric Ener ��j�* Total Credits 1.00 WSEC Prescriptive Worksheet(2010 edition)Zone 1 WSUEEPIO-010 Copyright 2010 Glazing Schedule Project Mformation Contact/nformation Plan 2758 Freestone Companies 6820 20th st E Yefm Fife WA 98424 253-896-1300 Rick Carlile 253-381-6080 Conditioned Floor Area � 2758 Sum of UA for Heating System Sizing 118.8 Sum of All Glazing Areas From Below 340 Glazing to Floor Area Ratio 12.33% 602.7.2 Exception Ratio(not to exceed 1%)�� Exterior poors Plan Component Door Percent Width Height Glazing Door poor ID Descri tion Ref. U-factor Glazed Qt. Feet Inch Feet �"`n Area Area UA Interior to ara e fiber lass fire-rated 0.160 1 3 6 20.0 3.2 One Exempt Swinging Door<24 Square Feet 1 3 6 20.0 Sum of Glazing Area, Door Area, and UA (do not include exempt door) 20.0 3.2 Area Weighted U= UA/,4rea 0.16 Sum of Area and UA for Heating system size only(include exempt door) 40.0 3.2 Vertical Glazing �Windows, Glazed doors using Exception 602.6#1) Plan Component Glazing Width Height Glazing �� Description Ref. U-factor Qt. Feet �"°n Feet �"�' Area UA 2 I, Low-e1 1/2" + ar on 0.340 1 6 5 30.0 10.20 2 I, Low-e1 1/2" +ar on 0.340 1 6 7 47.0 15.98 2 I, Low-e1 1/2" + ar on 0.340 2 4 4 32.0 10.88 2 I, Low-e1 1/2" + ar on 0.340 3 5 5 75.0 25.50 2 I, Low-e1 1/2" + ar on 0.340 4 2 2 20.0 6.80 2 I, Low-e1 1/2"+ar on 0.340 2 6 4 48A 16.32 2 I, Low-e1 1/2" +ar on 0.340 4 5 4 80.0 27.20 2 I, Low-e1 1/2"+ ar on 0.340 2 2 2 g,p 2 72 2 I, Low-e1 1/2" +ar on 0.340 2 I, Low-e1 1/2"+ ar on 0.340 2 I, Low-e1 1/2" + ar on 0.340 2 I, Low-e1 1/2" + ar on 0.340 , � : I Sum of Area and UA 340.0 115.60 Area Weighted U= UA/Area 0.34 � i � WSEC Prescriptive Worksheet(2010 Edition) i I � WSUEEPIO-010 Copyright 2010 i I ._-. "_.._.. �W�YFYI(IIWYYI Overhead Glazing ; Plan � Component Glazing Width Height ID Description Ref. ! U Qt. Feet �ncn Feet �nch Area UA I Sum of Area and UA Area Weighted U= UA/Area Doube Glazed Garden Windows Section 602.7.2 Exception Plan Component Width Height ID Description Qt. Feet Inch Feet �"`n Area UA Sum of Area Sum of Area X 3(This fotal is automatically included in the glazing area total.) Glazing UA for Heatinq System Size Only=Area X 0:63 i � � i � I i � i I I � i I I WSEC Prescriptive Worksheet(2010 Edition) ' I � , WSUEEPIO-010 Copyright 2010 I Simple Heating System Size: Climate Zone 1 AroJect In�ormation Contact Mformation Plan 2758 Freestone Com anies 6820 20th st E Yelm Fife WA 98424 253-896-1300 Rick Carlile 253-381-6080 Indoor Design Temperature 70 Outdoor Design Temperature 17 Design Temperature Difference (oT) DT=Indoor-Outdoor Design Temp 53 Conditioned Floor Area 275g Conditioned Volume 23306 Glazing Copy Sum of UA from Glazing Schedule 119 Attic U-Factor X Area = UA R-49 0.027 1516 40.9 R-38 Advanced 0.026 Single Rafter or Joist Vaulted Ceilings U-Factor X Area = UA R-38 Vented 0.027 � � Above Grade Walls U-Factor X Area = UA _ _ _ . R-21 0.056 2432 136.2 Floors U-Factor X Area = UA R-30 0.029 1242 36.0 � Below Grade Walls U-Factor X Area = UA 2' Depth Walls 0.042 _ _ 3.5' Depth Walls 0.041 7' Depth Walls 0.037 Slab Below Grade F-Factor X Len th = UA 2' Depth 0.59 3.5' Depth 0.64 T Depth 0.57 Slab on Grade F-Factor X Len th = UA R-10 2' perimeter 0.54 R-10 Full - Heated 0.55 Sum of UA 332 Envelope Heat Load � 17593 Btu/ Hour Sum of UA X�T Air Leakage Heat Load 13340 Btu/ Hour ((Volume X 0.6)X oT)X.018)) Building Design Heat Load 30933 Btu/ Hour Air Leakage+Envelope Heat Loss Building and Duct Heat Load 1.15 35573 Btu/Hour If ducts are located in unconditioned space:Sum of Building Heat Loss X 1.15 If ducts are located in conditioned space:Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 150% ; 53360 Btu/Hour Building and Duct Heat Loss X 1.50 ; WSEC Prescriptive Worksheet(2010 Edition) � WSUEEPIO-010 Copyright 2010 � U � � o � m N i � � � � � N i C N �, � � (Q � c� � � L � � o N � � U �"o � � � �•VN � � � � � Q� � aj V p >, � � � c� U � � � � 4� O � � � � > q Z o � � � V � c� � �� ti � � � � � � �y � �' cmU � � ° � � � � O � .`;� � � � � a � � � � � o � � � q � � �� � _ � � � � � � � -� �3 � � c�! �'� �� } Q �3 � rn � � � w � � �n �' p� w � � � � L. � � (A W � � � �� •'� � = UW � W Q-� � N � � � � UJ � � � � � O � w � cnoo � o � U � U Q � _ � � I— Q � pp � Z � '�p O V � � o � M � � � .cn c� � p N o � W v� Cp w Q p W M N � J � (a � LIJ N LL � � � ,� � � � � � � � J U � � N � Q C� cn � o � � � � �n ~ cn Z f— � � � �, O � O . . � N � (� y��'�iiE 2 � � � � J j � U �� 2 � � -� N Q � `� :N� �� Q � � � � � V � a� � Z Q � Y � � � L L � L � � 0�, � -� C C � � (�E � � ��r8d Cp � � m � Q f!) m ������,�o � ��3 0 �// 4 � � [i� � �B � e+� `� 9 � . � . �.o�xH�y� N4RTHWEST � In�ulation Ce�rtif�cate/Blo�er poor Te�t Fo�rm Batts&Blaulcets Thermal Perforxnance(Aftic Application) �. � - When installed in accozdance wiih the niauufacturer's The sfated thennal resistance(R-value)is provided by installing in accorda�ice with the rnauufacYurer's recoimnendations;ICuauf Uatts&blai�ets will provide instnicfions,tlie iequired inunber of bags per 1,000 sq.ft.of net area,at not less than the labeled nzinimun� tl�e full IZ-value. thiclmess.Failure to install both tl�e rec�uired number o£bags&at least tlte minimum thiclmess will result ' in lower insulation R-value. I:•Valoe �1i�iin�uut Thickncss R-Value [3a�s/I.ODU s . f.. �1a�innnn Co�cra�e \9inimiun 1\'eiehl Ivlininwn�Thicl.i;- css � To oblain an Installed insulaliou To obtain�n Tfte num6er of Conteuls of this bag The WeigIiU3F oC Installed insulation , insulation resis(ance shoufd nol be less ir�����';^^ �,�rt�i� nnn er.„�.,..� �i,,.,.ia..,,� ,.,,,,o,.,,,,,.., .,,���u.,.�;,,.-„��tia�� sltould not�e less � R-Value of: tlian: less dlan: lha�r �I ( .Lir / i . �'r R-3&HD 10.25"� - R 60 29.7 33.6 SF .9521bs. 19.750" R-38 12.00" R-49 23.5 42.5 SF .7531bs. T.6375" R-30 HD 8.25" R-44 20.9 47.8 SF .6701bs. 14.875" IL-30 10.00" R-38 17.8 56.2 SF .5691bs. 13.000" R26 9.00" R-30 13.6 733 SF .4371Us 10.375" P.-22 6.50" R-2G 11.8 85.0 SF 3771Us 9,125" R-21 HD 5.50" R-22 9.8 102.2 SF 313 Ibs 7.750" R-19 6.25"�'�° R-19 8.4 1193 SP' .2681bs 6.750" R-15 HD 3.50" R-13 5.7 1753 SP .1831bs 4.750" R-13 3.50" R-11 4.7 210.8 SF .1521Us 4.000" R-11 3.50" Bag Weigl�t-Nomina1301Us,Mininnun 29 Ibs.This product conforms to the perfonnauce requirements ofAST1VI C 764, T2-8 2.50" Type 1,&cancelled Pederal Speci�cation HH-1-1030B,Type 1,Blass B.R-Values are determined in accordance tivith '"�`R-18 in a 5.5"cavity.Confomis to ASTM C 687&C 518."R"means resistuice to heat flow.The higher the R-value,tlie greater the insulation power.To get the C665&Federal Specification HH-1-521F n7arked R-value,it is essential that the ansulation be installed properly.Tf you do It yourself,get insfructions&follow then To achieve labeled I2-value,this prodnct must be applied with a pneumatic blotiving macliine&a cornigaYed hose witli a minimum.25"internal corrugation,a minimum length of 150 ft.&a diamefer of at least 3".Coils in the hose should not be less than 36"in dia�neter.Acceptable material feed rate is 5-351bs./minute.Reconunended feed rate is 15-251bs./mimrtes. • ]6nilders Insu]ation Sfa4ement. - atts an or an:efs Iiave been insfalled in conformance witli tiie above 2009�SJCC Residentiat�ner�v Comnliance Certificafe-T3uildin��1ir Lealcnee reconmieudations to rovide a thennal resistauce of.... R-Value Standard Building&Test C dition: Comments: . Attic Area R- R-49 Date: Sloped Ceiling R- R-38 Time Walls R- R-21 Iudoor Temp: Floors(over uiilieated crawl space) R- R-30 Outdoor Temp: Floor Area(sq ft) Completedasof; �/ ��� �3uildin�AirLealcaee'Y'a➢�eef: SJL�I.essThan0.000�0 Tnstallers Nante Print: __,______. 'be_5_t#1-Depress_ I�_Press Prefecr$aselii:e Pressu:e (P1 List111ers Name Sagn: - Sid Press. a) Flow Rin Fan Aress. a Flow cfin Site Address: 1 ��' V W�i'��2 ��, S , 4 � U�� �Q`n� PosT Test Pressure: Fan Mode]/SN: �(„�J� F7 J`7 Results:SLA(Specific Lealcage Area):_� � 2�/'¢• �'�/�C.-�( I�ome Builders Signat�ire: 'I'est#2-Depress Press Pretest Baseline Pressure (Pa) Home Bnilders Address:_ Sld�Press, a Flow Rin Fan Rress, a I'loiv cfni Insulation Contractor: Tiisulation Northwest LLC � Post Test Pressure: Fan Model/SN: ' P.253-846-�12I P.O.Box 732069 Results:SLA(Specific Lealcage Area): • F.253-846-8096 Puvallup.WA.98373 �davit: I certify thal this Specific Leakage�1rea is accurate&detennined nsing Blower poor Test Standard 502.4.5 Building Air Lealcage Testing. Technician Name Prinf: /�,t �P7� Technician Name Si u: