20130311 Permit Pkg 09042013 woF''HEp� City of Yelm Permit No.: 20130311
o �
q � Community Development Department Issue Date: 9/04l2013
(Work must be compieted within 180 days)
Building Division
Phone: (360)458-8407
L
""`"'"`_°" Fax: (360)458-3144
Applicant:
Name: FREESTONE CHERRY MEADOWS LLC Phone: 253-896-1300
Address: 6820 20TH ST E STE A
FIFE WA 98424
Property Information:
Site Address: 15461 CHAD DR SE Owner: FREESTONE CHERRY
MEADOWS LLC
Assessor Parcel No.: 41610018000 Subdivision: CHERRY MEADOWS Lot: 180
Contractor Information:
Name: FREESTONE CHERRY MEADOWS LLC Phone: 253-896-1300
Address: RICK CARLILE
6820 20TH ST E STE A
FIFE WA 98424
Contractor License No.: FREESI'969NZ Expires: 1/24/2011
Project Information:
Project: NEW RESIDENTIAL BUILDING
Description of Work: LOT 180, PLAN 2758B
Sq. Ft per floor: First 1248 Heat Type (Electric, Gas, Other): GAS
Second 1516
Third
Garage 400
Basement
Fees:
Item Contractor Fees
NEW RESIDENTIAL BUILDING FREESTONE CHERRY MEADOWS LLC $16,848.43
MECHANICAL KLIEMANN BROS. $ 78.25
PLUMBING PELTRAM PLUMBING $ 118.00
TOTAL FEES: S 17,044.68
ApplicanYs Affidavit: OFFICIAL USE ONLY
I certify that I have read and examined the information contained within the application and know the same
to be true and . I also certify that the proposed structure is in conformity with all applicable City of #Sets of Prints:
Yelm regula' ns in uding those governing zoning an land s division,and in addition,all covenants,
easement nd re ridions of record_If app ing as a ontra or, I further certify that I am currently Final lnspection:
regis re in ate of Wash' n. �
Signatur , Date
Date:
Firm By�
i
Cit� of Y�lm
(36 } 458-84U2
kEC#: OU137523 9/04/2013 2:5U F�M
OPER: CO TERM: 001
REF#; 2601
TRAN; 33,0000 BUILDING PE�MITS
2.0130301 17,051 .18CR
FREESTONE CHERRY h1EADOWS L.LC
15467 CHAQ DR SE
6LD-RCS1 16,848.43CR
MECH 84.75CR
PL 118.00CR
TRAN: 33.0000 BUILDING PERMfTS
10130311 17,044,68CR
FREESTONE CHERRY MEADOWS LI�G
15461 CHAD DR SE
BLD-RES1 16,848,43CR
MECH 78.25CR
PL 118.00CR
TRAN; 33.0000 BUILDTNG PERMI�fS
2C1130312 17,328.OJCR
FREESTONE CNEkRY MEAD04VS LLC
15455 CHAD DR SE
BI.D-RES1 17,110,84CR
MECH 78,25CR
PL 139.00CR
TENDERED, 51 ,423.95 GNECK
APPLIEO: 51,423.9�-
CHANGE: 0.00
YELM COMMUNITY SCHOOLS
YELM WA 98597
Clerk: �roy
Terminal�
Receipt: � 215726
Manual Receipt;
NFREESTONE
6820S20TH�StLE SUITE A
FIFE, WA 98424
9/4/Z013 2:46 PM
�Qt Item
`------------- �-v._______.._..______ Price
� CPF MItIGATION
MITIGATION 3015,00
03-021/LpT �7g��5467 CHAD DR SE;YELM
r CPF MITIGATION
MITIGATION 3015.00
03-021/LQT 180/15461 CHAD DR SE;YELM
1 CPF MTTIGATION
MItIGATION 3015.00
03-021/LOT 181/15455 CHAD QR SE;YELM
Subtotal; 9045.Op
tax: 0.00
tatal; 9045.00
Check 9045.00
2602
Change Due; a Q�
THANK YOU
6.5' �2� 20' 17' ��
�.�..-�--•--- ( � s2.oa�
SCALE:1"-20' � ,eo �a,
� � — 3 a cY� �
� DRYWELL�
fn
N ZO X 92 !
FRONT PORGN � COV PATIQ � ;�
FOUN�ATiON AND � � � r I �
STEP TANK L�CATION — — — —
SHALL BE STAKED I 39 !
OUT �QR SET BACK � �
arvs��c�r�orv. ° � 275$ B R�V � �
51"EP TANK �
� ! DlAG 64.31' t °
EXCAVATION IN "
VIOLATION OF THE � � � w 4 �
REQU(RED 5'MINIMUM s.5�I ss� s. �
SET BACK TO
FOUNQATlON S�1ALL BE s•.,o.I �, 2 eAR f I
BACK�D F'iLLED WIl"H �.o. t8.5' GARAGE � I
CDF. � � ;� COV.PORCtt { �
e � a
2a.5'
q § ...... — _ — �
NO 5`EAVE ~ S..a- � CONC.
ENCROACNMENT ��r=^N�- DRlVE �'
THIS L(�T s-,o- e•.7•-' „.,� �
� / E �
CC}NNECT 4" PVC N / � N
ROOF DRAINS TQ �r�' � � � �o'UTILI3Y EStvIT
DRYWELL
s
�UvQ f u C�. ��L�Jl.(z 52.40 w
0
APf'RdXIMATE-- � 2a' �� �URB 1 GUTT�R N
�OCATIOFV OF
STREET 7REE
� GHAD DRI V� 5E� �
����6�C:��,J�L�
----:-�-____.�..__. l
. .
, � -______�� .��...,. � _! _ .�:__�.._,.3.
� � ...
�..;��?,,v,�.�'�,�� d � _._ .. � _ . _. ,...._._�..
���.�
� .�l.�N � � �I?�3
c���,��.
...
�.
- -
LCJT 180 - GHERRY MEADC� �y S
PARCEL #: 416100 180 00 � pat�: oW�,er: �reestone
06 / 25 /13 Gherr� Meadows LLG
Lo� 5fze� Pro�Ject Addre�5: 6820 20th 5t. E Svite A
�Ife, WA a8424
5,240 S�. Ft. 1546'f CHAD DRIVE SE 2s�-ea6-i�oo
��30
31I
CITY OF YELM
RESIDENTIAL BUILDING PERMIT APPLICATION FORM
� Project Address: � ��". c�� Parcel#: ''G'��(vCl �,�0 Q O
Subdivision: �ot#:�_ plan#: 17 Zoning:
�Q New Construction ❑ Re-Model/Re-Roof/Addition ❑ Home Occupation Sign
� Plumbing ❑ Mechanical ❑ Mobile/Manufactured Hom lacement ❑ Other
Project DescriptionlScope of Work: � ` Q
Pro)ect va�ue: 3 `
Building Area (sq. ft) 1"Floor�o�`�'0 2nd Floor��v_ Garage �
Basement � Carport — �o�
#Bedrooms� #Bathroom�., Heating:�OTHER or ELECTRIC (Circle One)
Are there any environmentally sensitive areas located on the parcel? �v
/fyes, a compieted environmental checklist must accompany permit application.
BUtLDING'OWNER NAM�: � C, ��
ADDRE S O EMAIL , .C�
C��' � STATE„J�_ZIP TELEPHONE (o- �p
ARCHfTECT/ENGINEEI� LICENSE#
ADDRESS a5 - EMAIL�_qr �q�q� n
CITY Rp�.h¢.� STATE ZIP ► TELEPHONE
GENERA�CONTRACTOf� e� TELEPHONE__ � =
ADDRESS EMAIL �
CITY�c' STATE IP FAX �o2+,-ri� gq�-O�e� —
CONTRACTOR'S LICENSE# E 2 EXP DATE � CITY LICENSE#
PLUMBING CONTRACTOF� e ��H
ADDR SS LEPHONE \- (
CiTY EMAIL
STAT Z 0 l FAX (aS�, 9 l -9�
CONTRACTOR'S LICENSE# O EXP DATE CiTY LICENSE#
� �O
MECHANICAL CONTRAGTOR • Ic TELEPHONE a6 5 -O
ADDRESS 0 `� EMAIL
CITY_i�ry�q.. STATE ZIP FqX (
CONTRACTOR'S LICENSE#kI,TEI�lF�4�0 1 Rr EXP DATE� CITY LICENSE#
Co � a'7 201�{
py of mitigation agreement with Yelm Community Schools, if applicable.
�hereby certity that the above informatlon Is correct and that the construction on,and the occupancy and the use of the
above ed property wf11 be In accordance witN the laws,rules and regulatlons of the State ot Waahington and tha
ty Ye m.
a ,�,
Appl(cant's Signatur Date ; �' � A
Owner/Contractor/Owner's Agent/ ontractor's Agent(Please circie one.) � � �-�
All permits are non-transferable and will expire if work authorized by such permit Is not begun
within 180 days of issuance, or if work is suspended or abandoned for a per�od nf,
���, ��'�""�.��T��
� � �l�N 2 7 2013
�
105 Yelm Auenue Weat '
Yelm, WA 98597 (,�8�45R.RA_44
www.ct.yelm.ma.ua (360)458-3144FAX
Prescriptive Energy Code Compliance for Single Family and Duplex Housing: Zone 1
Project mformation Contact Infomration
Plan 2758 Freestone Companies 6820 20th st E
Yefm Fife WA 98424 253-896-1300
Rick Carlile 253-381-6080
This set of forms has been developed to assist permit applicants documenting compliance with the
Washington State Ene�gy Code, (2009 edition�. This set is for structures built under the IRC and located
in Climate Zone 1.
The foi�owing forms provide much of the required documentation for plan review. The details noted here
must aiso be shown on the drawings (WSEC 104.2).
This form is not a substitute for the energy code itself. To obtain a copy of the energy code,
go to the following web address. http://www.energy.wsu.edu/code
Glazing
�o Glazing U-Factor poor 9 Vaulted Wall�Z Wall• int4 Wall• eat'� Slabb
Option Area : CeilingZ 3 Above Below Below Floors on
%ofFloor Vertical Overhead11 U-Factor Ceiling Grade Grade Grade Grade
R-49 or R-21
OO I 13% 0.34 0.50 0.20 R-38 R-38 Int.� R gl R-10 R-30 R2�0
Adv.
R-49 or R_21 R-21 R-10
O II 25% 0.32 O.SQ 0.20 R-38 R-38 Int.� TB R-10 R-30 2�
Adv.
R-49 or R-21 R-21 R-IO
O III Unlimited 0.30 0.50 0.20 R-38 R-38 Int.� TB R-10 R-30 2,
Adv.
See WSEC fab/e 6-1 forfootnotes
Glazing Schedule Attached to Document
� Does not apply. (SEE INSTRUCTIONS) Usin� Prescriptive Oqtion III.All glazing
and doors meet maximum U-factor.Alternate heating size method submitted.
0 Option I or II,Glazing to floor area limit (WSEC 60ZJ.2)
� Area weighted window,skylight or door U-factor(WSEC 602.7,2)
� As part of the heating system sizing calculation (IRC M14013 & WSEC 503.2.2)
Radiant sfab:
❑ R-10 foam insulation, continuous with thermal break (WSEC 502.1.4.9)
Chapter 9 Options Total of 1 Credit Required
Opt. Opt. Deseription
1a Hi h Efficienc HVAC Equipment 1 1.0 �
1b High Efficiency HVAC Equipment 2
1c High Efficiency HVAC Equipment 3
2 High Efficienc HVAC Distribution S stem
3a Efficient Buildin Envelope 1
3b Efficient Buildin Envelope 2
3c Super-Efficient Buildin Envelope 3
4a Air Leaka e Control and Efficient Ventilation
4b Additional Air Leaka e Control and Efficient Ventilation
5a Efficient Water Heatin , ��, d��j�,�
5b Hi h Effiecienc Water Heatin E
6 Small Dwellin Unit � ��N � �' �Q��
7 Lar e Dwelling Unit
8 Renewable Electric Ener ��j�*
Total Credits 1.00
WSEC Prescriptive Worksheet(2010 edition)Zone 1 WSUEEPIO-010 Copyright 2010
Glazing Schedule
Project Mformation Contact/nformation
Plan 2758 Freestone Companies 6820 20th st E
Yefm Fife WA 98424 253-896-1300
Rick Carlile 253-381-6080
Conditioned Floor Area � 2758 Sum of UA for Heating System Sizing 118.8
Sum of All Glazing Areas From Below 340
Glazing to Floor Area Ratio 12.33% 602.7.2 Exception Ratio(not to exceed 1%)��
Exterior poors
Plan Component Door Percent Width Height Glazing Door poor
ID Descri tion Ref. U-factor Glazed Qt. Feet Inch Feet �"`n Area Area UA
Interior to ara e fiber lass fire-rated 0.160 1 3 6 20.0 3.2
One Exempt Swinging Door<24 Square Feet 1 3 6 20.0
Sum of Glazing Area, Door Area, and UA (do not include exempt door) 20.0 3.2
Area Weighted U= UA/,4rea 0.16
Sum of Area and UA for Heating system size only(include exempt door) 40.0 3.2
Vertical Glazing �Windows, Glazed doors using Exception 602.6#1)
Plan Component Glazing Width Height Glazing
�� Description Ref. U-factor Qt. Feet �"°n Feet �"�' Area UA
2 I, Low-e1 1/2" + ar on 0.340 1 6 5 30.0 10.20
2 I, Low-e1 1/2" +ar on 0.340 1 6 7 47.0 15.98
2 I, Low-e1 1/2" + ar on 0.340 2 4 4 32.0 10.88
2 I, Low-e1 1/2" + ar on 0.340 3 5 5 75.0 25.50
2 I, Low-e1 1/2" + ar on 0.340 4 2 2 20.0 6.80
2 I, Low-e1 1/2"+ar on 0.340 2 6 4 48A 16.32
2 I, Low-e1 1/2" +ar on 0.340 4 5 4 80.0 27.20
2 I, Low-e1 1/2"+ ar on 0.340 2 2 2 g,p 2 72
2 I, Low-e1 1/2" +ar on 0.340
2 I, Low-e1 1/2"+ ar on 0.340
2 I, Low-e1 1/2" + ar on 0.340
2 I, Low-e1 1/2" + ar on 0.340
,
�
:
I
Sum of Area and UA 340.0 115.60
Area Weighted U= UA/Area 0.34
�
i
�
WSEC Prescriptive Worksheet(2010 Edition)
i
I
� WSUEEPIO-010 Copyright 2010
i
I
._-. "_.._.. �W�YFYI(IIWYYI
Overhead Glazing ;
Plan � Component Glazing Width Height
ID Description Ref. ! U Qt. Feet �ncn Feet �nch Area UA
I
Sum of Area and UA
Area Weighted U= UA/Area
Doube Glazed Garden Windows Section 602.7.2 Exception
Plan Component Width Height
ID Description Qt. Feet Inch Feet �"`n Area UA
Sum of Area
Sum of Area X 3(This fotal is automatically included in the glazing area total.)
Glazing UA for Heatinq System Size Only=Area X 0:63
i
�
�
i
�
I
i
�
i
I
I
� i
I
I
WSEC Prescriptive Worksheet(2010 Edition) '
I
�
, WSUEEPIO-010 Copyright 2010
I
Simple Heating System Size: Climate Zone 1
AroJect In�ormation Contact Mformation
Plan 2758 Freestone Com anies 6820 20th st E
Yelm Fife WA 98424 253-896-1300
Rick Carlile 253-381-6080
Indoor Design Temperature 70
Outdoor Design Temperature 17
Design Temperature Difference (oT)
DT=Indoor-Outdoor Design Temp 53
Conditioned Floor Area 275g
Conditioned Volume 23306
Glazing
Copy Sum of UA from Glazing Schedule 119
Attic U-Factor X Area = UA
R-49 0.027 1516 40.9
R-38 Advanced 0.026
Single Rafter or Joist Vaulted Ceilings
U-Factor X Area = UA
R-38 Vented 0.027 � �
Above Grade Walls U-Factor X Area = UA
_ _ _ .
R-21 0.056 2432 136.2
Floors U-Factor X Area = UA
R-30 0.029 1242 36.0
�
Below Grade Walls U-Factor X Area = UA
2' Depth Walls 0.042
_ _
3.5' Depth Walls 0.041
7' Depth Walls 0.037
Slab Below Grade F-Factor X Len th = UA
2' Depth 0.59
3.5' Depth 0.64
T Depth 0.57
Slab on Grade F-Factor X Len th = UA
R-10 2' perimeter 0.54
R-10 Full - Heated 0.55
Sum of UA 332
Envelope Heat Load � 17593 Btu/ Hour
Sum of UA X�T
Air Leakage Heat Load 13340 Btu/ Hour
((Volume X 0.6)X oT)X.018))
Building Design Heat Load 30933 Btu/ Hour
Air Leakage+Envelope Heat Loss
Building and Duct Heat Load 1.15 35573 Btu/Hour
If ducts are located in unconditioned space:Sum of Building Heat Loss X 1.15
If ducts are located in conditioned space:Sum of Building Heat Loss X 1
Maximum Heat Equipment Output 150% ; 53360 Btu/Hour
Building and Duct Heat Loss X 1.50 ;
WSEC Prescriptive Worksheet(2010 Edition)
� WSUEEPIO-010 Copyright 2010
�
U
� �
o �
m N i
� � � �
� N i C
N �, � �
(Q � c�
� � L � � o
N � � U �"o
� � � �•VN
� � � �
� Q� � aj V p >,
� � � c� U �
� � �
4� O � � � � >
q Z o
� � � V �
c� � ��
ti � � � � � �
�y � �' cmU
� � ° � �
� �
O � .`;� � � �
� a � � � �
� o
�
�
� q � � ��
� _ �
� � �
� � �
-� �3 � � c�!
�'� �� } Q �3 � rn
� � � w � � �n
�' p� w � � � � L.
� � (A W � � � ��
•'� � = UW � W Q-� �
N �
� � � UJ � � � � �
O � w � cnoo � o � U
� U Q
� _ � � I— Q � pp � Z � '�p O
V � � o � M � � � .cn c�
�
p N o � W v�
Cp w Q p W M N � J � (a
� LIJ N LL � � � ,�
� � � � � � � J U �
�
N � Q C� cn
� o �
�
� � �n ~
cn Z f— �
� � �, O � O . .
� N � (�
y��'�iiE 2 � � � � J j � U
�� 2 � � -� N Q � `�
:N� �� Q � � � � � V �
a� � Z Q � Y � �
� L L � L � �
0�, � -� C C � � (�E � �
��r8d Cp � � m � Q f!) m
������,�o � ��3 0 �//
4 � � [i� � �B � e+� `� 9 �
. � .
�.o�xH�y� N4RTHWEST �
In�ulation Ce�rtif�cate/Blo�er poor Te�t Fo�rm
Batts&Blaulcets Thermal Perforxnance(Aftic Application) �. � -
When installed in accozdance wiih the niauufacturer's The sfated thennal resistance(R-value)is provided by installing in accorda�ice with the rnauufacYurer's
recoimnendations;ICuauf Uatts&blai�ets will provide instnicfions,tlie iequired inunber of bags per 1,000 sq.ft.of net area,at not less than the labeled nzinimun�
tl�e full IZ-value. thiclmess.Failure to install both tl�e rec�uired number o£bags&at least tlte minimum thiclmess will result
' in lower insulation R-value.
I:•Valoe �1i�iin�uut Thickncss R-Value [3a�s/I.ODU s . f.. �1a�innnn Co�cra�e \9inimiun 1\'eiehl Ivlininwn�Thicl.i;- css �
To oblain an Installed insulaliou To obtain�n Tfte num6er of Conteuls of this bag The WeigIiU3F oC Installed insulation
, insulation resis(ance shoufd nol be less ir�����';^^ �,�rt�i� nnn er.„�.,..� �i,,.,.ia..,,� ,.,,,,o,.,,,,,.., .,,���u.,.�;,,.-„��tia�� sltould not�e less �
R-Value of: tlian: less dlan: lha�r �I
( .Lir / i . �'r
R-3&HD 10.25"� - R 60 29.7 33.6 SF .9521bs. 19.750"
R-38 12.00" R-49 23.5 42.5 SF .7531bs. T.6375"
R-30 HD 8.25" R-44 20.9 47.8 SF .6701bs. 14.875"
IL-30 10.00" R-38 17.8 56.2 SF .5691bs. 13.000"
R26 9.00" R-30 13.6 733 SF .4371Us 10.375"
P.-22 6.50" R-2G 11.8 85.0 SF 3771Us 9,125"
R-21 HD 5.50" R-22 9.8 102.2 SF 313 Ibs 7.750"
R-19 6.25"�'�° R-19 8.4 1193 SP' .2681bs 6.750"
R-15 HD 3.50" R-13 5.7 1753 SP .1831bs 4.750"
R-13 3.50" R-11 4.7 210.8 SF .1521Us 4.000"
R-11 3.50" Bag Weigl�t-Nomina1301Us,Mininnun 29 Ibs.This product conforms to the perfonnauce requirements ofAST1VI C 764,
T2-8 2.50" Type 1,&cancelled Pederal Speci�cation HH-1-1030B,Type 1,Blass B.R-Values are determined in accordance tivith
'"�`R-18 in a 5.5"cavity.Confomis to ASTM C 687&C 518."R"means resistuice to heat flow.The higher the R-value,tlie greater the insulation power.To get the
C665&Federal Specification HH-1-521F n7arked R-value,it is essential that the ansulation be installed properly.Tf you do It yourself,get insfructions&follow then
To achieve labeled I2-value,this prodnct must be applied with a pneumatic blotiving macliine&a cornigaYed hose witli a minimum.25"internal corrugation,a minimum length
of 150 ft.&a diamefer of at least 3".Coils in the hose should not be less than 36"in dia�neter.Acceptable material feed rate is 5-351bs./minute.Reconunended feed rate is
15-251bs./mimrtes. •
]6nilders Insu]ation Sfa4ement.
- atts an or an:efs Iiave been insfalled in conformance witli tiie above 2009�SJCC Residentiat�ner�v Comnliance Certificafe-T3uildin��1ir Lealcnee
reconmieudations to rovide a thennal resistauce of....
R-Value Standard Building&Test C dition: Comments: .
Attic Area R- R-49 Date:
Sloped Ceiling R- R-38 Time
Walls R- R-21 Iudoor Temp:
Floors(over uiilieated crawl space) R- R-30 Outdoor Temp:
Floor Area(sq ft)
Completedasof; �/ ��� �3uildin�AirLealcaee'Y'a➢�eef: SJL�I.essThan0.000�0
Tnstallers Nante Print: __,______. 'be_5_t#1-Depress_ I�_Press Prefecr$aselii:e Pressu:e (P1
List111ers Name Sagn:
- Sid Press. a) Flow Rin Fan Aress. a Flow cfin
Site Address: 1 ��' V W�i'��2 ��, S , 4 �
U�� �Q`n� PosT Test Pressure: Fan Mode]/SN: �(„�J�
F7 J`7
Results:SLA(Specific Lealcage Area):_� � 2�/'¢• �'�/�C.-�(
I�ome Builders Signat�ire: 'I'est#2-Depress Press Pretest Baseline Pressure (Pa)
Home Bnilders Address:_
Sld�Press, a Flow Rin Fan Rress, a I'loiv cfni
Insulation Contractor: Tiisulation Northwest LLC
� Post Test Pressure: Fan Model/SN: '
P.253-846-�12I P.O.Box 732069
Results:SLA(Specific Lealcage Area): •
F.253-846-8096 Puvallup.WA.98373
�davit: I certify thal this Specific Leakage�1rea is accurate&detennined nsing Blower poor Test Standard 502.4.5 Building Air Lealcage Testing.
Technician Name Prinf: /�,t �P7� Technician Name Si u: