20130127 Approved Full Plan Set 02262013
a (7 w u, b m LL n W a 0 F 0 a PROVIDENCE CT SUITE YELM MEDICAL OFFICE BUILDING CONSTRUCTION DOCUMENTS ABBREVIATIONS ACT ACOUSTICAL CEILING TILE FF FINISH FLOOR P PAINT ADDM ADDENDUM FIN FINISH PEN PENETRATION AFF ABOVE FINISHED FLOOR FL, FUR FLOOR PERP PERPENDICULAR E6A 1 TOSHIBA AMERICA MEDICAL SYSTEMS FRGWB FIBERGLASS REINFORCED GWB PJ PANELJOINT SD, ORD BOARD FT FEET It PROPERTY LINE BLDG BUILDING FTG FOOTING PL, P4.AM PLASTIC LAMINATE BLKG BLOCKING FUR FURRING, FURRED PLWD, PW PLYWOOD BM BEAM FX FIRE EXTINGUISHER PR PAIR B/0 BOTTOM OF PT PAINT, PAINTED, BRG BEARING GA GAUGE PRESSURE TREATED GALV GALVANIZED PtN PARTITION CAB CABINET GC GENERAL CONTRACTOR CCT CUBICLE CURTAIN TRACK GL GLASS, GLAZING RB RUBBER BASE CL, CL CENTER LINE GWB GYPSUM WALL BOARD R.O. ROUGH OPENING CJ CONTROL JOINT RUB RUBBER CLG CEILING HC HOLLOW CORE, HANDICAPPED CLR CLEAR HDWD HARDWOOD S SOUTH CMU CONCRETE MASONRY UNIT HDR HEADER Sc SOLID CORE CNTR COUNTER, COUNTER SUNK HM HOLLOW METAL SCWD SOLID CORE WOOD COL COLUMN HT HEIGHT SF SQUARE FEET CONC CONCRETE HR HOUR SHTG SHEATHING CONT CONTINUOUS SIM SIMILAR CORR CORRIDOR IBC INTERNATIONAL BUILDING CODE SO SQUARE CPT CARPET SS STEELSTUD CT CERAMIC TILE JAN JANITOR ST STAIN CTR CENTER STD STANDARD,STUD LTG LIGHTING STL STEEL DEL DOUBLE LL LEAD LINED DEG DEGREE T TEMPERED SAFETY GLASS DEPT DEPARTMENT MAX MAXIMUM T &B TOP AND BOTTOM OF DRINKING FOUNTAIN MDO MEDIUM DENSITY OVERLAY T&G TONGUEANDGROOVE DIA, 0 DIAMETER MDF MEDIUM DENSITY FIBER BOARD T.O. TOP OF DICA DRILLED IN CONCRETE ANCHOR MECH MECHANICAL TOM TOP OF MASONRY DIM DIMENSION MFR MANUFACTURER TOO TOPOFSTRUCTUREISTEEL DISP DISPENSER MIN MINIMUM TOW TOP OF WALL DN DOWN M.O. MASONRY OPENING TYP TYPICAL DS DOWN SPOUT MR METAL ROOFING DWG DRAWING M.S. METAL STUD LINO UNLESS NOTED OTHERWISE MTL METAL EA EACH VCT VINYL COMPOSITION TILE EQ EQUAL, EQUIPMENT N NORTH VTO VENTTOOUTSIDE EXST,(E) EXISTING NIC NOTINCONTRACT EXP EXPANSION, EXPOSED NTS NOT TO SCALE W WEST EXT EXTERIOR WI WITH of OVER W/O WITHOUT FAB FABRICATE OC ON CENTER WD WOOD FDN,PND FOUNDATION OPP OPPOSITE WGWB WATER RESISTANT GW6 FEC, FXC FIRE EXTINGUISHER CABINET WWF WELDED WIRE FABRIC DRAWING SET SYMBOL LEGEND GRIDLINE AND BUBBLE DETAIL NUMBER SHEIFTNUMBER �— DETAIL NUMBER SHEB:T NUMBER ROOM F0_00 I �Y PARTITION TYPE PARTITION CONFIG- URATION 1@ CEILING W A ` & STRUCTURE = INSULATION REO'D - =NO INSULATION REQ'D CPT -1 jE SV -1 4bro 00' AO CR O 01 DETAIL INTERIOR ELEVATION PROJECT TEAM OWNER \ REPRESENTATIVE: PROVIDENCE ST. PETER HOSPITAL 413 LILLY ROAD NE OLYMPIA WA 98508 OWNER 1 USER: PROVIDENCE HEALTH SYSTEM 914 SOUTH SCHEUBER ROAD CENTRAILIA, WA 98531 ARCHITECT: FINISH TRANSITIONS ELEVATION DOOR NUMBER AUTOMATIC OPEN SWITCH CARD READER (OR ELECTRONIC KEYPAD, COORD WITH OWNER VENDOR) RELITE TYPE EQUIPMENTTAG P.O. BOX 1797 GENTRALMV WA 98531 DRAWING INDEX A0.00 TGB ARCHITECTS A0.10 2191176TH AVE W, SUITE 210 ROOM NAMES EDMONDS, WA 98026 FLOOR PLAN, CEILING PLAN, FINISH PLAN - FIRST FLOOR CONTRACTOR: KEY NOTE ALDRLCH AND ASSOCIATES M1.0 810240TH STREET BE M2.0 BOTHELL, WA 98021 -9397 REVISION NUMBER FLOOR PLAN - HVAC E4.11 CT VENDOR: E6A 1 TOSHIBA AMERICA MEDICAL SYSTEMS E8.11 13005 NW33RD AVENUE VENDOR VANCOUVER, WA 98685 PARTITION TYPES COVER SHEET GN1 SHIELDING PHYSICIST: FINISH TRANSITIONS ELEVATION DOOR NUMBER AUTOMATIC OPEN SWITCH CARD READER (OR ELECTRONIC KEYPAD, COORD WITH OWNER VENDOR) RELITE TYPE EQUIPMENTTAG P.O. BOX 1797 GENTRALMV WA 98531 DRAWING INDEX A0.00 COVER SHEET A0.10 KEY PLAN AND CODE ANALYSIS FIRST FLOM ARCHITECTURAL A2.11 FLOOR PLAN, CEILING PLAN, FINISH PLAN - FIRST FLOOR A2.21 ELEVATIONS AND DETAILS MECHANICAL M1.0 COVER SHEET M2.0 FLOOR PLAN - PLUMBING M3.0 FLOOR PLAN - HVAC ELECTRICAL E0.01 COVER SHEET AND GENERAL NOTE E0.02 GENERAL NOTES E0.03 SPECIFICATIONS LUMINAIRE SCHEDULE E2.11 LIGHTING PLAN -1ST FLOOR E3.11 POWER PLAN -1ST FLOOR E3.12 ENLARGED PLANS & DETAILS E3.13 ENLARGED PLANS &DETAILS E3.14 ENLARGED PLANS & DETAILS E4.11 SYSTEMS PLAN -1ST FLOOR E6A 1 ONE -LINE DIAGRAM E8.11 PANEL SCHEDULES VENDOR C1 COVER SHEET GN1 GENERAL NOTES GN2 GENERAL NOTES Al EQUIPMENT LAYOUT A2 EQUIPMENT LAYOUT S1 STRUCTURALLAYOUT E7 ELECTRICAL LAYOUT E2 ELECTRICAL LAYOUT E3 ELECTRCIAL DETAILS E4 CABLE LENGTH DIAGRAM DEFERRED SUBMITTALS 1 SMOKE DETECTION, FIRE ALARM SYSTEM, AND FIRE SUPPRESSION SYSTEM TO BE DESIGNED TO MEET IBC CONTACT: GEOFFREY GLASS 903.3.1.1NFPA 13 STANDARD, IFC SECTION 904 AND 907, AND CURRENT MUNICIPAL REQUIREMENTS. PHONE: (360) 330493.7722 900ftY91ass@p-ldeace.org CONTACT: BOB HAKE PHONE: (360) 330 -8868 FAX: (360) M1219 mbed.heke @proNde .org CONTACT: GINA DAIS PHONE: (425) 778 -1530 FAX: (425)774 -7803 gdaisftberch tecW CONTACT: JONATHAN FAST PHONE: (425) 483 -1313 FAX: (425) 4WI016 jfasl @alddch -ess wm CONTACT: JOHNNIE WHITE JR. PHONE: (925)321 -1300 jwh6e @tems.cam CONTACT: JEREMY CORWIN, CHP PHONE: (360) 736£606 FAX: (360) 736.66 jemmy @cmanhpmm VICINITY MAP t 425.778.1530 21911 76th Ave W. Suite 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com 3626 REGISTERED EC STA F WASHINGTON 911 E YELM AVE YELM, WA 98597 COVER SHEET CONSTRUCTION DOCUMENTS 02/08/2013 KEY PLAN - FIRST FLOOR 1116" T-T .2 .8 - e 4 — — .4 PROJECT INFORMATION s 12050 -- 6 — .4 LEGEND "T" D I I kul ROOM NAME AND NUMBER REQUIRED EXITING 8 OCCUPANCY LOAD F-11 ii 3 r _ I I e�. -- �9Z ■ I 4■ Bnii ■il i,._ � I J I I � , i I I lil I - - r I CODE ANAL 1116 " =1-0' CODE INFORMATION PROJECT DESCRIPTION: INTERIOR BUILD OUT OF CT SCAN ROOM THAT WAS PREVIOUSLY SHELL SPACE. CONSTRUCTION TYPE FIRE EXTINGUISHER II -B, NON -RATED CONSTRUCTION FULLY SPRINKLED (AUTOMATIC SYSTEM COMPLIANT WITH IBC 903.3.11 AND NFPA 13 STANDARDS) EXIT PATH OCCUPANCY: "B " - BUSINESS OCCUPANT LOAD FOR YELM FAMILY MEDICINE: (B =iPERMSF) 11,065 SF =111 EXIT SIGN OCCUPANT LOAD FOR PROVIDENCE S PAC LAB: IB= I PER 1N BO 3,580 SF= 36 OCCUPANT LOAD POSTING TO BE POSTED IN A CONSPICUOUS PLACE ON AN APPROVED SIGN NEAR THE MAIN EXIT RELATED APPLICATIONS: CML SITE PLAN = BSP419-0347-YL BUILDING (SHELL AND CORE) = BLD- OW24 -YL CRS #60090724 BUILDING (TI) It BLD- 20100106 IS - FIRST FLOOR LEGAL DESCRIPTION: PARCELA PARCEL A OF BOUNDARY LINE ADJUSTMENT No. BLA -BBA1, AS RECORDED DECEMBER 2,1986 UNDER FILE No. 8612010084. EXCEPTING THEREFROM THAT PORTION CONVEYED TO THE CITY OF YELM, A MUNICIPAL CORPORATION FOR RIGHT- OF-WAY PURPOSES APRIL 27, 2007 UNDER AUDITORS FILE NO. 3922330. PARCELS: PARCEL B OF BOUNDARY LINE ADJUSTMENT NO. GLAAB-01, AS RECORDED DECEMBER 2, 19M UNDER FILE No. 5812020094. EXCEPTING THEREFROM THAT PORTION CONVEYED TO THE CITY OF YELM, A MUNICIPAL CORPORATION FOR RIGHT -OF -WAY PURPOSES APRIL 27, 2007 UNDER AUDITOR'S FILE NO.3922331. PARCEL C. A PORTION OF THE SOUTHWEST QUARTER OF THE NORTHEAST QUARTER OF SECTION 24, TOWNSHIP 17 NORTH, RANGE 1 EAST, W.M. DESCRIBED AS FOLLOWS: COMMENCING AT THE INTERSECTION OF THE NORTH LINE OF THE SOUTHWEST QUARTER OF THE NORTHEAST QUARTER OF SECTION 24, TOWNSHIP 17 NORTH, RANGE 1 EAST, W.M., WITH THE SOUTHWESTERLY RIGH -OF -WAY LINE OF THE OPYMPIA -YELM COUNTY ROAD; THENCE SOUTHEASTERLY ALONG SAID SOUTHWESTERLY RIGHT -OF -WAY LINE 220 FEET TO THE POINT OF THE BEGINNING OF THIS DESCRIPTION; THENCE SOUTHWESTERLY AND AT RIGHT ANGLES TO SAID COUNTY ROAD 570.18 FEET; THENCE SOUTHEASTERLY PARALLEL WITH SAID COUNTY ROAD 220 FEE; THENCE NORTHEASTERLY AT RIGHT ANGLE TO SAID COUNTY ROAD 570.18 FEET TO THE SOUTHWESTERLY RIGHT -OF -WAY LINE OF SAID ROAD; THENCE NORTHWESTERLY ALONG SAID RIGHT -OF -WAY LINE 220 FEET MORE OR LESS TO THE POINT OF BEGINNING. EXCEPTING THEREFROM THAT PORTION CONVEYED TO THE CITY OF YELM, A MUNICIPAL CORPORATION FOR RIGHT -OF -WAY PURPOSES APRIL 27, 2007 UNDER AUDITOR'S FILE 140.3922329. IN THURSTON COUNTY, WASHINGTON PARCEL: 21724130600 ,21724130500,21724130602 FIRE PROTECTION SYSTEMS: FIRE PROTECTION SYSTEMS ARE BY BIDDER DESIGN UNDER SEPARATE PERMIT. SUBMITTAL DEFERRED. SMOKE DETECTION, FIRE ALARM SYSTEM, AND FIRE SUPPRESSION SYSTEM TO BE DESIGNED TO MEET IBC 903.3.1.11NFPA QUICK RESPONSE STANDARDS, AND AUTHORITIES HAVING JURISDICTION. APPLICABLE CODES: UILDING CODE PERSLDGDEPT ""''' IRE CODE _ PER13LDODEPT NTL FI ECHANICAL CODE PER BLDG DEPT NTL M PE '. UMBING CODE R BLDG DEPT J NIF01 LECTRICAL CODE PER BLDG DEPT ATL E -2009 1BLDGDEPT WA STATE ENERGYCO6E- 2009__ i BLDG DEPT_ WMANSI 117.1(ACCESSIBILIT ) DOH CRS 10 FGI t 425.778.1530 2191176thAve W. Suite 210 If 425.774.7803 EdmondsWA98026 info@tgbarchitects.com www.tgbarchitects.com 911 E YELM AVE YELM, WA 98597 KEY PLAN CODE ANALYSIS FIRST FLOOR BID SET TBD PROJECT INFORMATION PROJECT NO: _ _ 12050 PROJECT MANAGER: GMO DRAWN BY - -.. KK SHEET NO 114" = 1' -F m 0 t7 w E E 8 4 0 a J LL M LL ti Q 0 0 J a G1 nnR PI AN - FIRST FLOOR - NEW CONSTRUCTION AREA OF WORK 22 -2" ow • 1 4-4` r - DEMO CABINET ✓ /'INTWV EW sR OM j � J J . `40 .,,.ow.•r«.mn�..+, STOR • r r• AND COUNTERTOP 1 - - - - - • ' oa•.c 1410 ,�. . a L 1405 • xe,orccwva..m,ur L ) ( )p , L7RA i �2 2 T v :XRAY 142 1418 - 1az & -, 1 C4 , -- CONTROL 1403] -s I CTS — — mx ' � d I Liaos FEC ■• ■ aw\\w p wpw ■a••aw \wt \p \pwpwaww ■•www•awr HALL iLEO ,C - - -_ -, 1414 1415 " I SERVER -� U 14177] ED PR EDU [R M PARTIAL FI OOR PLAN - FIRST FLOOR - DEMO RECEPTION TOIL i id0 141 WARI 1400 — ;AL 11 IRESSING 14131 1.t M AREA OF WORK TB. STOR � D D 1410 • +AC ULTRA 1a -0'AFF TSC C Ai SO_ UND I •N 4 _ o La1- 8 XY L - TWLET DO C R L RA CONTROL A Y�J \\\wasp\ 1az�_— L -1420 } _ _ —��� TOIL+ )—�-- 2 PARTIAL CEILING PLAN - FIRST FLOOR AREA OF WORK --\ B 0)--AT— i • (D- L1- : L -T I TOILET 4 PARTIAL FINISH PLAN - FIRST FLOOR CEILING PLAN LEGEND A +10' -0" CEILING HEIGHT, AFF 2X4 FIXTURE (EXISTING TO BE RE- NSTALLED IN NEW GRID) _ t7 RECESSED CAN FIXTURE, DIMMABLE 20 ACOUSTIC CEILING TILES, ARMSTRONG, SECOND LOOK, CIRRUS 513 KEYNOTES OPROVIDE 1 58M LEAD LINED, 518" GWB IN WALIIDOORIWINDOW FROM FLOOR TO r -W. PROVIDE 0.79MM LEAD SHIELDING IN WALL TO LEAD SHIELDED CEILING. O2 PROVIDE 0.79MM LEAD LINED 518 "GWB FROM FLOOR TO LEAD SHIELDED CEILING, O PROVIDE 0.79MM LEAD LINED 51B" GWB IN CEILING, ATTACHED TO 2ND FLOOR SLAB STRUCTURE ABOVE. SEE TYPICAL LEAD PARTITION DETAIL 4/A221. 5 VEMIFY EXISTING DOOR 8 FRAME MEET LEAD REQUIREMENT RATING, PER 51A2.21. GENERAL NOTES 1 DETAILS INDICATED AS "TYPICAL SHOW TYPICAL CONFIGURATIONS WHERE INDICATED CONDITIONS OCCUR. SUCH DETAILS MAY OR MAY NOT BE REFERENCED ELSEWHERE IN THESE DOCUMENTS BUT ALWAYS OCCUR AT GIVEN CONDITIONS UNLESS NOTED OTHERWISE. 2 DO A4OT SCALE DRAWINGS, NOTIFY ARCHITECT OF ANY DISCREPANCIES, 3 THERE SHALL BE NO EXPOSED PIPE, CONDUIT, DUCTS, VENTS, ETC. ALL SUCH LINES SHALL BE CONCEALED OR FURRED d FINISHED, UNLESS NOTED OTHERWISE. 4 ADD SINGLE LAYER OF 518" GW'B TO PERIMETER WALLS TO 6" ABOVE FINISHED CEILING. 5 1 SEE TYPICAL LEAD PARTITION DETAIL 41A2.2,. 6 r 7 FLOORING TO EXTEND UNDERCOUNTER, WHERE APPLICABLE. 8 SEE DETAIL 21A2.21 FOR TYPICAL CEILING TILE DETAIL. 9 ALL CEILING MOUNTED ITEMS (I E. LIGHT FIXTURES, GRILLES, DIFFUSERS, SPEAKERS, EXIT LIGHTS, ETC.) SHALL BE LOCATED IN THE CENTER OR QUARTER CENTER OF ACT (AS INDICATED ON THE CEILING PLAN) OR GWB SOFFITS, UNLEBB NOTED OTHERWISE. COORDINATE WITH MECHANICAL AND ELECTRICAL. r PROVIDE FIRE DAMPERS AT ALL SUPPLY AND RETURN AIR OUTLETS, INLETS, OR DUCTS PENETRATING FIRE RATEC ASSEMBLIES, ENCLOSURES, WALLS, FLOORS, OR SURFACES, AND AS REQUIRED BY FIRE DEPARTMENT, IF ApPLICABLE. MECHANICAL DESIGN IS UNDER SEPARATE PERMIT. 11 COORDINATE ALL CEILING MOUNTED EQUIPMENT SUPPORT REQUIREMENTS, LOCATIONS, DIMENSIONS, ECT. WITH EQUIPMENT SUPPLIER AND OWNER7TENANT, PRIOR TO INSTALLATION. FLOOR PATTERN LEGEND t -' !� SAWCUT SLAB ON GRADE WALKED DUCT TRENCH CONTROA DIRAY 408 MCT- 2 -FORDO .767 RUST s. P -10 ITO MATCH SW8385 CACHET CREAM ROOM L 1,408- - t�t 1.n TECH WORK L -T I TOILET 4 PARTIAL FINISH PLAN - FIRST FLOOR CEILING PLAN LEGEND A +10' -0" CEILING HEIGHT, AFF 2X4 FIXTURE (EXISTING TO BE RE- NSTALLED IN NEW GRID) _ t7 RECESSED CAN FIXTURE, DIMMABLE 20 ACOUSTIC CEILING TILES, ARMSTRONG, SECOND LOOK, CIRRUS 513 KEYNOTES OPROVIDE 1 58M LEAD LINED, 518" GWB IN WALIIDOORIWINDOW FROM FLOOR TO r -W. PROVIDE 0.79MM LEAD SHIELDING IN WALL TO LEAD SHIELDED CEILING. O2 PROVIDE 0.79MM LEAD LINED 518 "GWB FROM FLOOR TO LEAD SHIELDED CEILING, O PROVIDE 0.79MM LEAD LINED 51B" GWB IN CEILING, ATTACHED TO 2ND FLOOR SLAB STRUCTURE ABOVE. SEE TYPICAL LEAD PARTITION DETAIL 4/A221. 5 VEMIFY EXISTING DOOR 8 FRAME MEET LEAD REQUIREMENT RATING, PER 51A2.21. GENERAL NOTES 1 DETAILS INDICATED AS "TYPICAL SHOW TYPICAL CONFIGURATIONS WHERE INDICATED CONDITIONS OCCUR. SUCH DETAILS MAY OR MAY NOT BE REFERENCED ELSEWHERE IN THESE DOCUMENTS BUT ALWAYS OCCUR AT GIVEN CONDITIONS UNLESS NOTED OTHERWISE. 2 DO A4OT SCALE DRAWINGS, NOTIFY ARCHITECT OF ANY DISCREPANCIES, 3 THERE SHALL BE NO EXPOSED PIPE, CONDUIT, DUCTS, VENTS, ETC. ALL SUCH LINES SHALL BE CONCEALED OR FURRED d FINISHED, UNLESS NOTED OTHERWISE. 4 ADD SINGLE LAYER OF 518" GW'B TO PERIMETER WALLS TO 6" ABOVE FINISHED CEILING. 5 1 SEE TYPICAL LEAD PARTITION DETAIL 41A2.2,. MCT-5- FORGO- 614C1WRCOAL CL28M It 425.778.1530 21911 76th Ave W. Suite 210 f 425.774.7803 Edmonds WA 98026 i nfo@tgbarchitects,com www.tgbarchitects.com 911 E YELM AVE YELM, WA 98597 PARTIAL FIRST FLOOR PLANS ISSUANCE CONSTRUCTION DOCUMENTS 6 ALL WALLS TO RECEIVE 4 ". RUBBER BASE - ARMSTRONG IX Uuvme. 7 FLOORING TO EXTEND UNDERCOUNTER, WHERE APPLICABLE. 8 SEE DETAIL 21A2.21 FOR TYPICAL CEILING TILE DETAIL. 9 ALL CEILING MOUNTED ITEMS (I E. LIGHT FIXTURES, GRILLES, DIFFUSERS, SPEAKERS, EXIT LIGHTS, ETC.) SHALL BE LOCATED IN THE CENTER OR QUARTER CENTER OF ACT (AS INDICATED ON THE CEILING PLAN) OR GWB SOFFITS, UNLEBB NOTED OTHERWISE. COORDINATE WITH MECHANICAL AND ELECTRICAL. 10 PROVIDE FIRE DAMPERS AT ALL SUPPLY AND RETURN AIR OUTLETS, INLETS, OR DUCTS PENETRATING FIRE RATEC ASSEMBLIES, ENCLOSURES, WALLS, FLOORS, OR SURFACES, AND AS REQUIRED BY FIRE DEPARTMENT, IF ApPLICABLE. MECHANICAL DESIGN IS UNDER SEPARATE PERMIT. 11 COORDINATE ALL CEILING MOUNTED EQUIPMENT SUPPORT REQUIREMENTS, LOCATIONS, DIMENSIONS, ECT. WITH EQUIPMENT SUPPLIER AND OWNER7TENANT, PRIOR TO INSTALLATION. FLOOR PATTERN LEGEND FLOOR PLAN LEGEND !� SAWCUT SLAB ON GRADE WALKED DUCT TRENCH t Y' !. I .. MCT -I- FORGO.707 BARLEY 4 L.L1a, PAINT SCHEDULE MCT- 2 -FORDO .767 RUST s. P -10 ITO MATCH SW8385 CACHET CREAM MCT-5- FORGO- 614C1WRCOAL CL28M It 425.778.1530 21911 76th Ave W. Suite 210 f 425.774.7803 Edmonds WA 98026 i nfo@tgbarchitects,com www.tgbarchitects.com 911 E YELM AVE YELM, WA 98597 PARTIAL FIRST FLOOR PLANS ISSUANCE CONSTRUCTION DOCUMENTS 02/08/2013 PROJECT INFORMATION _.. -. PROJECT NO: -. 1205D. PROJECT MANAGER GMD DRAWN BY: __.. -. _. KK SHEET NO All 1 N m c K W rn EXISTING COLUMN 18' DEEP P4.AM STORAGE CABINET w/112' FIXED P -LAM DIVIDERS, EQUALLY SPACED RELOCATED BASE CABINET PATCH AND REPAIR COUNTERTOP CONTROL ROOM INTERIOR ELEVATION FY 114"= 1'-0' sHIELDED ROOM S LEAD - BACKED GWB FRAME ANCHOR 12' FROM TOP AND BOTTOM T -0' O.C. MAX CT SCAN 114"= V -0" HMFRAME -- , PARTITION AS SCHEDULED J IUNPHIELDED ROOM SIDE LEAD SHIELDED RELITE, HEAD JAMB AND SILL 3' =1'4Y 2' -0' LNG ----------------- WASTE RECEPTACLE, FIO I I �I i II I I II I i I i , I II i I I I � - -- P-LAM BACKSPLASH, AS NOTED ON INTERIOR ELEVATION REMOVABLE 16GA SENT ALUMINUM TRASH DEFLECTOR WIRE PULL P -LAM DOOR TOE KICK, AS SCHEDULED CTYPICAL WASTE RECEPTACLE BASE CABINET 3 I li2' =;; -0" PARTITION AS SCHEDULED UNSHIELDED 80MRO�DEE DOOR JAMB AT LEAD LI 3 " -1 -0' RECON I UNIT ELEVATION 4781 I* MIN LEAD OVERLAP pw F CUBICLE CURTAIN DETAIL 12 GA. HANGER WIRES 24' O.C. IN ADDITION TO TYP. SUSPENSION WIRES FIRE TREATED WOOD BLCCKING CONT. FOR LENGTH OF TRACK AND OVER ONE TEE BEYOND ENDS (2) 810 WD SCREWS MIN. 1-1/V EMBEDMENT INTO BLOCKING @ 24' O.C. STD (SCHED 40) SPACES CUBICLE CURTAIN TRACK CEILING SYSTEM EXISTING COLUMN PROVIDE FINISHED BACKSPLASH AT EXTERIOR WINDOW 20' DEEP P- AM WORK SURFACE IN WALL SUPPORT BRACKET CT SCAN INTERIOR ELEVATION 1478 114" =1' -0' METAL STUD LEAD BATTEN T WIDE X 7'A' HIGH LEAD - BACKED GWB EXISTINGCOLUMN PROVIDE FINISHED BACKSPLASH AT EXTERIOR WINDOW 20' DEEP P4AM WORK SURFACE IN WALL SUPPORT BRACKET CASEWORK P LAM LEGEND UPPERSfLOWERS FORMICA, MOFS0LIDZ7812 -58 COUNTER/BACKSPLASH: FORMICA, WHEAT STRAND 6212 -58 �, 9• J30 H18 D15 G15 T36 CT SCAN INTERIOR ELEVATION ,4'e l TYPICAL METAL STUD TYPICAL INSIDE CORNER TYPICAL LEAD-BACKED GWB METAL STUD DETAILS awB 0 $H ATTACH (HEAVY-DUTY) CEILING GRID MEMBERS TO TWO ADJACENT WALLS, AND ALLOW 3/4" CLEARANCE TO CEILING GRID MEMBERS ON THEIR OPPOSITE WALLS. ACCOMPLISH BY MEANS OF 7/8" WALL MOLDINGS ALL AROUND WITH MFR'S SEISMIC CLIPS ALL AROUND. PROVIDE HANGERS WITHIN 8" OF PERIMETER WALLS, ALL SIDES; PROVIDE CISCA- COMPLIANT SEISMIC BRACING WITH COMPRESSION STRUTS, FOR CEILINGS GREATER THAN SF TYPICAL SUSPENDEND CEILING DETAIL 3' =1'-0' ACOUSTICAL CEILING PANELS TYPICAL OUTSIDE CORNER P -LAM SOFFIT DIGITAL LOCKS, TYP 18" DEEP P-AM FULL HEIGHT CABINET REMOVABLE ACCESS PANEL LEAD BATTEN 2" WIDE X TA" HIGH LEAD - BACKED GWB NOTE THE FOLLOWING: FURNISH CEILING GRID (SUSPENSION SYSTEM) IN ACCORDANCE WITH ASTM C-635 INSTALL CEILING GRID IN ACCORDANCE WITH ASTM C -636, INCLUDING PROVISIONS ON WIRE HANGERS, ATTACHMENT OF WIRE HANGERS, SPACING OF WIRE HANGERS, CARRYING CHANNELS, SPLICES, ASSEMBLY DEVICES, AND CEILING FIXTURES. INSTALL CEILING GRID IN ACCORDANCE WITH THE ADDITIONAL INFORMATION ON THIS DE FAIL, WHICH IS A SUMMARY OF THE CISCA (ARCHITECTURAL) STANDARDS FOR SEISMIC DESIGN CATEGORY D. INSTALL CEILING- MOUNTED ITEMS AND FIXTURES, INCLUDING LIGHT FIXTURES, MECHANICAL SERVICES, CABLE TRAYS, CONDUIT AND SIMILAR IN ACCORDANCE WITH CISCA STANDARDS FOR DESIGN CATEGORY D. THIS MAY INCLUDE INDEPENDENT SUPPORT FOR SOME CEILING - MOUNTED ITEMS. IN CEILINGS WITHOUT LATERAL BRACING (CEILINGS LESS THAN 1006 SF) PROVIDE FLEXIBLE CONNECTIO FROM SPRINKLER BRANCH LINES TO SPRINKLER HEADS, IN LIEU OF OVERSIZED SPRINKLER OPENINGS IN CEILING IN CEILINGS GREATER THAN 2500 SF, PROVIDE 2" WIDE MINIMUM CEILING JOINT AS INDICATED AND DETAILED ON CEILING PLANS, t 425.778.1530 21911 76th Ave W. Suite 210 If 425.774.7803 Edmonds WA 98026 Info @tgbarchltects.com www.tgbarchitects.com 911 E YELM AVE YELM, WA 96597 DETAILS CONSTRUCTION DOCUMENTS 02/08/2013 PROJECT INFORMATION PH _ROOM SIDE PROJECT NO: LEAD- BACKED GWB PROJECT MANAGER: LEAD -LINED HM FRAME SEE ---- FRAME TYPES FOR TYP DIMENSIONS AND NOTES-- a 4X4 STL TUBE FROM FLOOR TO STRUCTURE ABOVE- - - - - -' HMFRAME -- , PARTITION AS SCHEDULED J IUNPHIELDED ROOM SIDE LEAD SHIELDED RELITE, HEAD JAMB AND SILL 3' =1'4Y 2' -0' LNG ----------------- WASTE RECEPTACLE, FIO I I �I i II I I II I i I i , I II i I I I � - -- P-LAM BACKSPLASH, AS NOTED ON INTERIOR ELEVATION REMOVABLE 16GA SENT ALUMINUM TRASH DEFLECTOR WIRE PULL P -LAM DOOR TOE KICK, AS SCHEDULED CTYPICAL WASTE RECEPTACLE BASE CABINET 3 I li2' =;; -0" PARTITION AS SCHEDULED UNSHIELDED 80MRO�DEE DOOR JAMB AT LEAD LI 3 " -1 -0' RECON I UNIT ELEVATION 4781 I* MIN LEAD OVERLAP pw F CUBICLE CURTAIN DETAIL 12 GA. HANGER WIRES 24' O.C. IN ADDITION TO TYP. SUSPENSION WIRES FIRE TREATED WOOD BLCCKING CONT. FOR LENGTH OF TRACK AND OVER ONE TEE BEYOND ENDS (2) 810 WD SCREWS MIN. 1-1/V EMBEDMENT INTO BLOCKING @ 24' O.C. STD (SCHED 40) SPACES CUBICLE CURTAIN TRACK CEILING SYSTEM EXISTING COLUMN PROVIDE FINISHED BACKSPLASH AT EXTERIOR WINDOW 20' DEEP P- AM WORK SURFACE IN WALL SUPPORT BRACKET CT SCAN INTERIOR ELEVATION 1478 114" =1' -0' METAL STUD LEAD BATTEN T WIDE X 7'A' HIGH LEAD - BACKED GWB EXISTINGCOLUMN PROVIDE FINISHED BACKSPLASH AT EXTERIOR WINDOW 20' DEEP P4AM WORK SURFACE IN WALL SUPPORT BRACKET CASEWORK P LAM LEGEND UPPERSfLOWERS FORMICA, MOFS0LIDZ7812 -58 COUNTER/BACKSPLASH: FORMICA, WHEAT STRAND 6212 -58 �, 9• J30 H18 D15 G15 T36 CT SCAN INTERIOR ELEVATION ,4'e l TYPICAL METAL STUD TYPICAL INSIDE CORNER TYPICAL LEAD-BACKED GWB METAL STUD DETAILS awB 0 $H ATTACH (HEAVY-DUTY) CEILING GRID MEMBERS TO TWO ADJACENT WALLS, AND ALLOW 3/4" CLEARANCE TO CEILING GRID MEMBERS ON THEIR OPPOSITE WALLS. ACCOMPLISH BY MEANS OF 7/8" WALL MOLDINGS ALL AROUND WITH MFR'S SEISMIC CLIPS ALL AROUND. PROVIDE HANGERS WITHIN 8" OF PERIMETER WALLS, ALL SIDES; PROVIDE CISCA- COMPLIANT SEISMIC BRACING WITH COMPRESSION STRUTS, FOR CEILINGS GREATER THAN SF TYPICAL SUSPENDEND CEILING DETAIL 3' =1'-0' ACOUSTICAL CEILING PANELS TYPICAL OUTSIDE CORNER P -LAM SOFFIT DIGITAL LOCKS, TYP 18" DEEP P-AM FULL HEIGHT CABINET REMOVABLE ACCESS PANEL LEAD BATTEN 2" WIDE X TA" HIGH LEAD - BACKED GWB NOTE THE FOLLOWING: FURNISH CEILING GRID (SUSPENSION SYSTEM) IN ACCORDANCE WITH ASTM C-635 INSTALL CEILING GRID IN ACCORDANCE WITH ASTM C -636, INCLUDING PROVISIONS ON WIRE HANGERS, ATTACHMENT OF WIRE HANGERS, SPACING OF WIRE HANGERS, CARRYING CHANNELS, SPLICES, ASSEMBLY DEVICES, AND CEILING FIXTURES. INSTALL CEILING GRID IN ACCORDANCE WITH THE ADDITIONAL INFORMATION ON THIS DE FAIL, WHICH IS A SUMMARY OF THE CISCA (ARCHITECTURAL) STANDARDS FOR SEISMIC DESIGN CATEGORY D. INSTALL CEILING- MOUNTED ITEMS AND FIXTURES, INCLUDING LIGHT FIXTURES, MECHANICAL SERVICES, CABLE TRAYS, CONDUIT AND SIMILAR IN ACCORDANCE WITH CISCA STANDARDS FOR DESIGN CATEGORY D. THIS MAY INCLUDE INDEPENDENT SUPPORT FOR SOME CEILING - MOUNTED ITEMS. IN CEILINGS WITHOUT LATERAL BRACING (CEILINGS LESS THAN 1006 SF) PROVIDE FLEXIBLE CONNECTIO FROM SPRINKLER BRANCH LINES TO SPRINKLER HEADS, IN LIEU OF OVERSIZED SPRINKLER OPENINGS IN CEILING IN CEILINGS GREATER THAN 2500 SF, PROVIDE 2" WIDE MINIMUM CEILING JOINT AS INDICATED AND DETAILED ON CEILING PLANS, t 425.778.1530 21911 76th Ave W. Suite 210 If 425.774.7803 Edmonds WA 98026 Info @tgbarchltects.com www.tgbarchitects.com 911 E YELM AVE YELM, WA 96597 DETAILS CONSTRUCTION DOCUMENTS 02/08/2013 PROJECT INFORMATION PROJECT NO: 12050 PROJECT MANAGER: GMD _.KK. DRAWN BY:.. SHEET NO I SYM SYMBOL ABBY. DESCRIPTION DESCRIPTION DESCRIPTION BALL VALVE 1412.E EACH SYSTEM SHALL BE PROVIDED WITH AT LEAST ONE TEMPERATURE CONTROL D4 T'STAT GATE VALVE O S SWITCH Nr COS CHECK VALVE W AFF GLOBE VALVE w ARCH. GAS COCK A MINIMUM. CBS SOLENOID / MODULATING VALVE RCQUIREMENTS OF CHAPTER 13, DAMPERS SHALL COMPLY WITH SECTION 1412.4.1 BE CDL THREE -WAY VALVE ACCOMPLISHING A REDUCTION IN OF ENERGY USE THROUGH CONTROL SETBACK OR CGS RELIEF VALVE BALANCING VALVE -r 17V CGL CEILING GRILLE -LAY IN FLOW CONTROL VALVE (SEr FOR 1 GPM) COP COEFFICIENT OF PERFORMANCE -- * AUTO -FLOW CONTROL VALVE DEMOLISH * * PRV PRESSURE REDUCING VALVE DRAWING 20 UNION -�� 40 ELECT. THERMOMETER PRESSURE GAUGE VIBRATION ISOLATOR VAV 1.24 w Q 4010 WATER HAMMER ARRESTOR ENERGY EFFICIENCY RATING 18 EFF STRAINER 35 FR ANCHOR 3E 3E th_l�.D(d GENERAL CONTRACTOR BACKFLOW PREVENTION DEVICE HSPF HEATING SEASONAL PERFORMANCE FACTOR HOSE BIBB • VTR VENT THROUGH ROOF QO CO CLEANOUT I.E. S or W SOIL or WASTE IPLV ------ - - - - -- V VENT - - - - - - CW COLD WATER - - - - - - - - - - HW HOT WATER ------- - - - - -- HWC HOT WATER RECIRCULATION MECHANICAL HWC HOT WATER RECIRCULATION WITH HEAT TRACE TAPE RL RL RAIN LEADER ---- - - - - -- ORE - ORL OVERFLOW RAIN LEADER D D DRAIN G G GAS C C CONDENSATE TPL TPL TRAP PRIMER LINE B O DUCT SECTION - SUPPLY O 10 "0 CDL DUCT SECTION - RErURN RECTANGULAR DUCT (INSIDE DIMENSION) ROUND DUCT SOUND LINED DUCT (INSIDE DIMENSION) FLEXIBLE DUCT ADJUSTABLE AIR EXTRACTOR TURNING VANE TYPE (CEILING DIFF. LAY -IN) 20x12 300 CFM 12 "0 20x12 f� 3" (125) FIXTURE UNITS or BTUH PIPE SIZE VD VOLUME DAMPER MD MOTORIZED DAMPER __O BDO BACKDRAFT DAMPER SD DUCT SMOKE DEFECTOR BOL LIST 1411.1: EQUIPMENT SHALL HAVE A MINIMUM PERFORMANCE AT THE SPECIFIED RATING SYMBOL ABBV. DESCRIPTION DESCRIPTION SEALED. 1412.E EACH SYSTEM SHALL BE PROVIDED WITH AT LEAST ONE TEMPERATURE CONTROL O T'STAT THERMOSTAT O S SWITCH © COS CARBON MONOXIDE SENSOR 1412.2: WHEN USED TO CONTROL BOTH HEATING AND COOLING EQUIPMENT ZONE AFF ABOVE FINISHED FLOOR A(,CORDANCE WITH SMACNA DUCT LEAKAGE TEST PROCEDURES - 1985. ARCH. ARCHITECT /ARCHITECTURAL A MINIMUM. CBS CEILING DIFFUSER- SURFACE MOUNTED RCQUIREMENTS OF CHAPTER 13, DAMPERS SHALL COMPLY WITH SECTION 1412.4.1 BE CDL CEILING DIFFUSER -LAY IN ACCOMPLISHING A REDUCTION IN OF ENERGY USE THROUGH CONTROL SETBACK OR CGS CEILING GRILLE - SURFACE MOUNTED 1432.2.1: AIR SYSTEMS SERVING MULTIPLE ZONES SHALL HAVE CONTROLS TO CGL CEILING GRILLE -LAY IN 0 COP COEFFICIENT OF PERFORMANCE -- * X DEMOLISH * * SIMULTANEOUSLY ARE PROHIBITED EXCEPT AS NOTED IN SECTION 1435. DWG DRAWING 20 E. EXIST. EXISTING ITEMS 40 ELECT. ELECTRICAL VAV 1.24 EC ELECTRICAL CONTRACTOR 4010 EER ENERGY EFFICIENCY RATING 18 EFF EFFICIENCY /EFFICIENT 35 FR FLOOR REGISTER GC GENERAL CONTRACTOR HSPF HEATING SEASONAL PERFORMANCE FACTOR HWR HIGH WALL REGISTER HWG HIGH WALL GRILLE I.E. INVERT ELEVATION IPLV INTEGRATED PART LOAD VALUE LWR LOW WALL REGISTER LWG LOW WALL GRILLE MC MECHANICAL CONTRACTOR MECH. MECHANICAL OFCI OWNER FURNISHED, CONTRACTOR INSTALLED e POD POINT OF CONNECTION TYR TYPICAL J.O.N. UNLESS OTHERWISE NOTED WC1 PLUMBING FIXTURE TAG EF 2 EQUIPMENT TAG 1� FLAG NOTE CONNECTION (NECK) SIZE 10 "0 CDL TYPE (CEILING DIFF. LAY -IN) 300 CFM FLOW RATE (CUBIC FEET PER MINUTE) f� 3" (125) FIXTURE UNITS or BTUH PIPE SIZE DETAIL NUMBER 1 SHEET ON WHICH DETAIL IS DRAWN SECTION INDICATOR SHEET ON WHICH SECTION IS DRAWN Q REVISION TAG GENERAL NOTES INSTALL ALL PIPING ON ROOM SIDE OF BUILDING INSULATION. MECHANICAL DRAWINGS ARE DIAGRAMMATIC IN NATURE, AND DO NOT NECESSARILY REFLECT EVERY REQUIRED OFF -SET, FITTING OR ACCESSORY. COORDINATE INSTALLATION OF MECHANICAL SYSTEMS WITH BUILDING STRUCTURE AND ALL OTHER TRADES. THE MECHANICAL CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO BEGINNING WORK IN ORDER TO OBSERVE EXISTING CONDITIONS. VERIFY EXACT SIZE, LOCATION AND CONDITION OF ALL EXISTING SYSTEMS, DUCTS, PIPES, UTILITIES AND BUILDING STRUCTURE. VERIFY VOLTAGES AT THE SITE PRIOR TO ORDERING ANY EQUIPMENT ALL MECHANICAL EQUIPMENT LOCATED IN CEILING CAVITIES THAT REQUIRE ELECTRICAL CONNECTION SHALL HAVE AN 8 -1/2 "01" LAMINATED SIGN PERMANENTLY MOUNTED ON THE ELECTRICAL ENCLOSURES THAT INDICATES: "THIS EQUIPMENT MUST HAVE A MINIMUM ACCESS OF 36" (LESS THAN 46OV) AND 42" (460V AND ABOVE) ". NO TRADE SHALL BLOCK THIS SPACE EVEN IF SHOWN ON THE DRAWINGS. INSTALL SIGN PRIOR TO INSTALLATION OF EQUIPMENT. ALL MECHANICAL EQUIPMENT THAT REQUIRES ACCESS FOR COIL PULL, FILTER CHANGE, MOTOR CHANGE, COMPRESSOR CHANGE, LUBRICATION, SHEAVE AND BELT CHANGE, FAN CHANGE OUT, ETC. SHALL HAVE AN 8 -1/2 "01" LAMINATED SIGN PERMANENTLY MOUNTED ON THE EQUIPMENT ACCESS PANELS THAT INDICATES "THIS EQUIPMENT MUST HAVE A MINIMUM ACCESS OF 36 ". NO TRADE SHALL BLOCK THIS SPACE. 2009 WASHINGTON STATE ENERGY CODE NOTES 1411.1: EQUIPMENT SHALL HAVE A MINIMUM PERFORMANCE AT THE SPECIFIED RATING 1414.1: DUCTWORK (OTHER THAN ROUND OR FLAT OVAL) WHICH IS DESIGNED TO CONDITIONS NOT LESS THAN THE VALUES SHOWN IN TABLES 14 -1A THROUGH 14 -1G. OPERATE AT PRESSURES ABOVE 1/2" WATER COLUMN STATIC PRESSURE SHALL BE DESCRIPTION SEALED. 1412.E EACH SYSTEM SHALL BE PROVIDED WITH AT LEAST ONE TEMPERATURE CONTROL FLOOR PLAN - HVAC DEVICE. EACH ZONE SHALL BE CONTROLLED BY INDIVIDUAL THERMOSTATIC CONTROL RET. VOL CFM RESPONDING TO TEMPERATURE WITHIN THE ZONE AT A MINIMUM, EACH FLOOR OF A 1414.1.2: ALL LOW PRESSURE DUCT SYSTEMS SHALL BE SEALED TO A LEAKAGE RATE BUILDING SHALL BE CONSIDERED AS A SEPARATE ZONE. NOT TO EXCEED 6% OF THE FAN FLOW IF THE DUCT SYSTEM HAS MORE THAN 25% HW DUCT SURFACE AREA LOCATED IN ANY UNCONDITIONED SPACE. THE LEAKAGE RATE 1412.2: WHEN USED TO CONTROL BOTH HEATING AND COOLING EQUIPMENT ZONE SIiALL BE CONFIRMED THROUGH FIELD VERIFICATION AND DIAGNOSTIC TESTING, IN THERMOSTAT CONTROLS SHALL BE CAPABLE OF A DEADBAND OF AT LEAST 57. WITHIN A(,CORDANCE WITH SMACNA DUCT LEAKAGE TEST PROCEDURES - 1985. WHICH THE SUPPLY OF HEATING AND COOLING ENERGY IS SHUT OFF OR REDUCED TO 0 A MINIMUM. 1414.2: INSULATION OF SUPPLY, RETURN AND OUTSIDE AIR DUCTWORK SHALL MEET THE CONTROL 1409 /XRAY 1408 RCQUIREMENTS OF CHAPTER 13, DAMPERS SHALL COMPLY WITH SECTION 1412.4.1 BE 1412.4: HVAC SYSTEMS SHALL BE EQUIPPED WITH AUTOMATIC CONTROLS CAPABLE OF INSULATED IN ACCORDANCE WITH TABLE 14 -5. ACCOMPLISHING A REDUCTION IN OF ENERGY USE THROUGH CONTROL SETBACK OR WRISTBLADE HANDLES, 2.2 GPM MAX LAMINAR FLOW SPOUT, GRID DRAIN, SCREWDRIVER STOPS & SUPPLIES, 17 GA EQUIPMENT SHUTDOWN DURING PERIODS OF NON -USE OR ALTERNATE USE OF THE 1432.2.1: AIR SYSTEMS SERVING MULTIPLE ZONES SHALL HAVE CONTROLS TO SPACES SERVED BY THE SYSTEM. AIUTOMATICALLY RESET SUPPLY AIR TEMPERATURE BY REPRESENTATIVE BUILDING LOADS OR 0 OUTSIDE AIR TEMPERATURE. 1412.2 EACH AIR SUPPLY OUTLET OR AIR OR WATER TERMINAL DEVICE SHALL HAVE Lbs 147 132 MEANS FOR BALANCING, INCLUDING BUT NOT LIMITED TO, DAMPERS, TEMPERATURE AND 1435: SYSTEMS WHICH PROVIDE HEATING AND COOLING TO THE SAME ZONE PRESSURE TEST CONNECTIONS AND BALANCING VALVES. SIMULTANEOUSLY ARE PROHIBITED EXCEPT AS NOTED IN SECTION 1435. PLUMBING FIXTURE SCHEDULE SHEET DESCRIPTION LOCAL CONNECTIONS TAG DESCRIPTION FLOOR PLAN - PLUMBING M3.0 FLOOR PLAN - HVAC EX VOL. ACH RET. VOL CFM RET. VOLI ACH PRESS. I +,-ORE W V HW CW 31 CT SCAN SINK -ONE COMPARTMENT (STAINLESS STEEL COUNTER MOUNT) JUST SL- 2125 -A -GR 21 "X25 ", 8" DEPTH, JUST 2.5 0 0 0 0 J -35 CP SINK STRAINER, CHICAGO 786, 10" GOOSENECK SPOUT W /CERAMIC DISC CARTRIDGES, 8" CENTERS, 4" CONTROL 1409 /XRAY 1408 340 3400 1200 S1 WRISTBLADE HANDLES, 2.2 GPM MAX LAMINAR FLOW SPOUT, GRID DRAIN, SCREWDRIVER STOPS & SUPPLIES, 17 GA 2" 1-1/2" 1/2" 1/2" 0 CHROME PLATED OFFSET P -TRAP. PLUMBEREX PRO -2000 SERIES P- TRAP /HI &C WATER COVERS. Volts 480-3 480-3 Lbs 147 132 VAV 7.23 PRICE DRAWING INDEX SHEET DESCRIPTION MIO COVER SHEET M2.0 FLOOR PLAN - PLUMBING M3.0 FLOOR PLAN - HVAC EX VOL. ACH RET. VOL CFM ROOM PRESSURIZATION SCHEDULE ROOM AREA SQ.FT VOL I CU. FT. SUP. VOL. I CFM SUP.VOL. ACH OSA VC)L CFM OSA ACH EX VOL. CFM EX VOL. ACH RET. VOL CFM RET. VOLI ACH PRESS. I +,-ORE CT SCAN 1418 365 1 3650 1 1900 31 150 2.5 0 0 0 0 + CONTROL 1409 /XRAY 1408 340 3400 1200 21 120 2.1 0 0 0 0 + Volts 480-3 480-3 Lbs 147 132 VAV 7.23 PRICE FDCS 5014 14 77.50 20 20 46 40 55 1 VAV 1.24 PRICE FDC5 4010 10 75 18 17.50 32 35 SERIES FAN POWERED TERMINAL UNIT SCHEDULE Tag ID Mfr Model Unit Sz. Inlet Sz. Dis. H (in) Dis. W (in) Case H (in) Case L (in) Case W (in) S Air pY Tmp °F Ste Steps Cap kW 15 10.50 Current Amps 18.04 12.63 Di1F. SP (in w g) 1 1 Discharge Alt. DASS None Downstream SP Gn w9) 0.40 0.40 EAT °F 70 68 Fan Flow 1900 1200 Fan Motor Voltage 277 277 Heater Type ELECTRIC ELECTRIC Inlet Attenuator LA'S None ktlet SP (in w9) 1 1 LAT °F 94.95 95.65 Liner Std Std Max Pd. CFM 1900 1100 Max Discharge NC 24 25 Max Radiated NC 40 38 Min Pd. CFM 500 400 Mitt Oper PD (in.wg) 0.06 0.08 MOP 25 20 Motor FLA 5 4 Motor HP 3/4 1/2 Return Height 18 15.50 Return Width (in) 21 16 Volts 480-3 480-3 Lbs 147 132 VAV 7.23 PRICE FDCS 5014 14 77.50 20 20 46 40 55 1 VAV 1.24 PRICE FDC5 4010 10 75 18 17.50 32 35 55 1 w. o.oa .. ..ora..,una umcu uym, r nuc m mm�umuwmr. B -Sound power levels and NC's are based on tests conducted in accordance with ARI Standard 88058. C -Room NC levels shown include attenuation factors obtained from ARI Standard 885 -98. D -Check submittal drawings for exact dimensions. E - Airflow units are cubic feet per minute, water flow units are US galons per minute, all temperatures in degrees Fahrenheit, heat loss in feet of water, air pressure drop in inches ofwater gauge. F -Airl units are liters per second, water flow units are liters persecond, all temperatures in degrees Centigrade, hegt loss in kilopascals, air pressure drop in Pascals. G - Blanks ( -) indicate a sound power level of INC under 20. H - Water coil performance has been rated and certified in accordance wth the edition ofARl Standard 410. t 425.778.1530 21911 76th Ave W. Suite 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tg ba rc h i tects.co m RICE GROUP, Inc. Consulting Engineer 20201 Cedar Valley Road Suite 120 Lynnwood, WA 98036 (425) 774 -3829 (425) 672 -2084 FAX 201 TAHOMA BLVD SE YELM, WA 98597 COVER SHEET ISSUANCE CONSTRUCTION DOCUMENTS 02/08/2013 r PROJECT INFORMATION W__PROJECT NO: 12050 PROJECT MANAGER:_ RH N DRAWN BY _ KLY sees Cl) J \.. / (B) AREA OF WORK- ........................... '.. v..................... ............... .L:j i� X 1 : .........................r. .............................................. r' CONNECT WASTE PIPE TO EXISTING WASTE. FIELD VERIFY i i SAWCUT SLAB AS REQUIRED EXISTING PIPE LOCATION. l � , Y- - -- TECH�-1 MAMMO WORK; 1419 } 1415 _'I1 SERVER PLAN NORTH 1 BELOW SLAB PLAN — PLUMBING Scale: 1/4" = 1' -0" , r � 1 r 11 x of LTRA OUND 1422 IN -- - - - - -- AREA OF WORK- ...................... ....................... I TOILET .............. STOR. 1410 Ili I 1423 �.. s,` .I" CONTROL ii 1 5, ROOM ; 1409 o i , I r .. ,. a�a FEC-............................ $ ....--------- • - - - -- --------------------- - - - - -� I, CLEA I CONNECT NEW SINK HW /CW AND VENT 1420 I,VERIFY LOCATION OF EXIS FIELD I L i PIPING TO EXISTING PIPINV� I INO PIPING TOILET 01 TECH { 141-2 PLAN NORTH FLOOR PLAN — PLUMBING Scale: 1/4" = 1' -0" `— rLU I' a 0 t 425.778.1530 21911 76th Ave W. Suite 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com WWW.tg ba rc h i tects.co m RICE GROUP, Inc. Consulting Engineers 20201 Cedar Valley Road Suite 120 Lynnwood, WA 98036 (425) 774 -3829 (425) 672 -2084 FAX 201 TAHOMA BLVD SE YELM, WA 98597 PARTIAL FIRST FLOOR PLAN - PLUMBING ISSUANCE CONSTRUCTION DOCUMENTS 02108/2013 PROJECT INFORMATION PROJECT NO: _ 12_050_ PROJECT MANAGER: _ RH _ DRAWN BY: KLY SHEET NO M2.0 r I 10 "0 CDL 300 GEM I LTRA OUND T0q 142 III10"0 CDL T -300 CFM �AV 1.22 )4x1 2 150 CF L.,..I i 8..0 50 12"0 CDL 2"0 CDL / 3. \ TYPICAL I 500 CFM 500 CFM ` M3.0) 8 "0 COL 2424 CGL - j 1 JPP;Y OUTLET i 1 1111 ®tiNgl ®It. CDL 18 "0 12"0 CDL .... 450 CFM.....:.. 12x12 3 M3.0 1417 DUCTLESS SPLIT UNIT 0 r`.:,:, CEILING (a :)RETURN GRILLE WITH BOOT DETAIL M3.0 SCALE: NTS PERFORATED PLATE ACROSS PLENUM. TOP OF PLATE AT CENTERLINE OF INLET MAX 12 "-� SCREW PLENUM TO DIFFUSER NECK- LAY -IN CEILING CEILING MIN 6" IgEy1t111 "11i 691tl:19 MAX 6" ROUND OR FLAT OVAL CONNECTION SIZE I NOTE. SET DIFFUSER FOR FOUR -WAY HORIZONTAL FLOW UNLESS AIR FLOW INDICATED ON DRAWINGS. TO PLENUM FLEX DUCT, SAME SIZE AS DIFFUSER INLET (ROUND EQUIVALENT) -CLAMP TYP. 1111"1 - SPIN -IN FITTING WITH VOLUME DAMPER HARD ROUND DUCT AS REQUIRED TO LIMIT FLEX DUCT LENGTH TO MAX 8' -0" (2 )DIFFUSER CONNECTION DETAIL M3.0 SCALE: NTS PLENUM TO BE FLEX CONNECTION (TYPICAL) SOUND LINED ELECTRIC HEATER PROVIDE TRANSITION TERMINAL BOX AS NECESSARY -- -- - -- .. VAV BOX II MIN 24" STRAIGHT DUCT) MIN 36" STRAIGHT DUCT PRIOR TO TAKF -OFFS OR FITTINGS 42" MIN. HORIZONTAL CLEARANCE FROM FACE % �� OF ELECTRICAL CONTROL PANEL. 30" MIN. J /// HATCHED HORIZONTAL ACCESS AND AREA HORIZONTAL SHOULDER CLEARANCE IN FRONT UNDER BOX TO BE MAINTAINED CLEAR FOR ACCESS. T -BAR CEILING TO BE REMOVABLE AND LABELED FOR REMOVAL. 3 VAV BOX INSTALLATION DETAIL M3.0 SCALE: NIS t 425.778.1530 21911 76th Ave W. Suite 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tg barch itects.com RICE GROUP, Inc. Consulting Engineers 20201 Cedar Valley Road Suite 120 Lynnwood, WA 98036 (425) 774 -3829 (425) 672 -2084 FAX 201 TAHOMA BLVD SE YELM, WA 98597 PARTIAL FIRST FLOOR PLAN - HVAC ISSUANCE CONSTRUCTION DOCUMENTS 02/08/2013 ILI r PROJECT INFORMATION (B) NOTE: RELOCATE DIFFUSERS AS REQUIRED TO AVOID A/C ;UPPLY EXCLUSION ZONE FOR CT SCANNER. REA WORK- ..................... I�� 50 12"0 CDL 2"0 CDL / 3. \ TYPICAL I 500 CFM 500 CFM ` M3.0) 8 "0 COL 2424 CGL - j 1 JPP;Y OUTLET i 1 1111 ®tiNgl ®It. CDL 18 "0 12"0 CDL .... 450 CFM.....:.. 12x12 3 M3.0 1417 DUCTLESS SPLIT UNIT 0 r`.:,:, CEILING (a :)RETURN GRILLE WITH BOOT DETAIL M3.0 SCALE: NTS PERFORATED PLATE ACROSS PLENUM. TOP OF PLATE AT CENTERLINE OF INLET MAX 12 "-� SCREW PLENUM TO DIFFUSER NECK- LAY -IN CEILING CEILING MIN 6" IgEy1t111 "11i 691tl:19 MAX 6" ROUND OR FLAT OVAL CONNECTION SIZE I NOTE. SET DIFFUSER FOR FOUR -WAY HORIZONTAL FLOW UNLESS AIR FLOW INDICATED ON DRAWINGS. TO PLENUM FLEX DUCT, SAME SIZE AS DIFFUSER INLET (ROUND EQUIVALENT) -CLAMP TYP. 1111"1 - SPIN -IN FITTING WITH VOLUME DAMPER HARD ROUND DUCT AS REQUIRED TO LIMIT FLEX DUCT LENGTH TO MAX 8' -0" (2 )DIFFUSER CONNECTION DETAIL M3.0 SCALE: NTS PLENUM TO BE FLEX CONNECTION (TYPICAL) SOUND LINED ELECTRIC HEATER PROVIDE TRANSITION TERMINAL BOX AS NECESSARY -- -- - -- .. VAV BOX II MIN 24" STRAIGHT DUCT) MIN 36" STRAIGHT DUCT PRIOR TO TAKF -OFFS OR FITTINGS 42" MIN. HORIZONTAL CLEARANCE FROM FACE % �� OF ELECTRICAL CONTROL PANEL. 30" MIN. J /// HATCHED HORIZONTAL ACCESS AND AREA HORIZONTAL SHOULDER CLEARANCE IN FRONT UNDER BOX TO BE MAINTAINED CLEAR FOR ACCESS. T -BAR CEILING TO BE REMOVABLE AND LABELED FOR REMOVAL. 3 VAV BOX INSTALLATION DETAIL M3.0 SCALE: NIS t 425.778.1530 21911 76th Ave W. Suite 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tg barch itects.com RICE GROUP, Inc. Consulting Engineers 20201 Cedar Valley Road Suite 120 Lynnwood, WA 98036 (425) 774 -3829 (425) 672 -2084 FAX 201 TAHOMA BLVD SE YELM, WA 98597 PARTIAL FIRST FLOOR PLAN - HVAC ISSUANCE CONSTRUCTION DOCUMENTS 02/08/2013 ILI r PROJECT INFORMATION —LV- m PB ELr-CTRICAL RISER GROUND CIRCUIT BREAKER NUMBER INDICATED TRIP SETTING AND NUMBER OF POLES PANELBOARD CURRENT TRANSFORMER (CT) CABLE TO BUS CONNECTION AUTOMATIC TRANSFER SWITCH (ATS) FEEDER TYPE - REFER TO FEEDER SCHEDULE ON ONE -LINE UTILITY METER POWER MONITOR WATTHOUR METER TVSS RACEWAYS RACEWAY CONCEALED IN WALL OR CEILING, EXPOSED IN UNFINISHED AREAS RACEWAY CONCEALED BELOW FLOOR FLEXIBLE CONDUIT FIXTURE WHIP WITH CONDUCTORS BRANCH CIRCUIT WIRING SHOWING CIRCUIT HOME RUN TO PANELBOARD. HASHMARKS SHOW QUANTITY OF CONDUCTORS WHEN MORE THAN THREE REQUIRED DOT INDICATES GROUND CONDUCTOR NEUTRAL CONDUCTOR SHOWN LARGER. PROVIDE DEDICATED NEUTRAL FOR EACH CIRCUIT. RACEWAY TURNING UP RACEWAY TURNING DOWN CIRCUIT CONTINUATION LOW VOLTAGE WIRING JUNCTION BOX PULL BOX RECEPTACLES Irm ELECTRICAL SYMBOLS RECEPTACLE - NEMA 5 -15R (NEMA 5 -20R FOR DEDICATED CIRCUIT) LIGHTING DUPLEX RECEPTACLE - ABOVE COUNTER. COORDINATE W/ ARCH. ELEVATIONS ELA1 FIXTURE TYPE - SEE SCHEDULE RECEPTACLE - GROUND FAULT INTERRUPTING D DUPLEX RECEPTACLE - DEDICATED (NEMA 5 -20R) y� 1 RECEPTACLE - COMPUTERS LIGHTING FIXTURE. DOUBLE — ${, ADJACENT NUMERAL INDICATES CIRCUIT GROUPING 30A/3P 6a LOWER -CASE LETTER DENOTES SWITCHING RECEPTACLE - CEILING MOUNTED FVNR DOUBLE DUPLEX RECEPTACLE - CEILING MOUNTED, PROJECTORS EQUIPMENT CONNECTION � o— MECHANICAL EQUIPMENT CALLOUT. REFER TO MECHANICAL COILING MOUNTED DOT SIGN (SINGLE FACE) - PROVIDE RECEPTACLE - CEILING MOUNTED, PROJECTORS 4v WITH ARROWS AS SHOWN AIR SOLENOID VALVE PNL DOUBLE CEILING MOUNTED EXIT SIGN (DOUBLE FACE) - PROVIDE SPECIAL RECEPTACLE - TYPE AS INDICATED WITH ARROWS AS SHOWN CORD REEL RECPT Y WALL MOUNTED EXIT SIGN AUTOMATIC TRANSFER SWITCH GO GARBAGE DISPOSAL REF REFRIGERATOR AWG $abc SINGLE POLE SWITCH - SUBSCRIPT INDICATES GROUNDING ELECTRODE CONDUCTOR READ REQUIRED SWITCHING DUTY. PROVIDE ONE SWITCH FOR EACH GEN GENERATOR SWITCHING DUTY SHOWN. RANGE HOOD BBO $2 DOUBLE POLE SWITCH GROUND FAULT CIRCUIT INTERRUPTER RMC $3 THREE -WAY SWITCH BLEACHERS Fv-,] $D DIMMER SWITCH RANGE XXX $K KEY OPERATED SWITCH GAS SOLENOID VALVE RSD ROLLING STEEL DOOR C CONDUIT HH $OS SWITCH WITH OCCUPANCY SENSOR SMOKE DAMPER CAB CABINET HID HIGH INTENSITY DISCHARGE SF $P SWITCH WITH PILOT LIGHT CIRCUIT BREAKER HP HORSEPOWER SOLV SOLENOID VALVE CCTV CLOSED CIRCUIT TELEVISION SWITCH WITH TIMER HIGH POWER FACTOR SPEC SPECIFICATION CKT CIRCUIT 0 4 ILLUMINATION CONTROL STATION (ICS) - SEE SCHEDULE SINGLE POLE, SINGLE THROW OS OCCUPANCY SENSOR, IR, CEILING MOUNT HT HEAT TRACE ® OCCUPANCY SENSOR, DUAL TECHNOLOGY, 360' CEILING COFFEE MAKER IF! MOUNT STD STANDARD H0� OCCUPANCY SENSOR, DUAL TECHNOLOGY, WALL MOUNT ICE MACHINE © CONTACTOR CO CONDUIT ONLY ® RELAY SW SWITCH © DAYLIGHT SENSOR J -BOX JUNCTION BOX —LV- m PB ELr-CTRICAL RISER GROUND CIRCUIT BREAKER NUMBER INDICATED TRIP SETTING AND NUMBER OF POLES PANELBOARD CURRENT TRANSFORMER (CT) CABLE TO BUS CONNECTION AUTOMATIC TRANSFER SWITCH (ATS) FEEDER TYPE - REFER TO FEEDER SCHEDULE ON ONE -LINE UTILITY METER POWER MONITOR WATTHOUR METER TVSS RACEWAYS RACEWAY CONCEALED IN WALL OR CEILING, EXPOSED IN UNFINISHED AREAS RACEWAY CONCEALED BELOW FLOOR FLEXIBLE CONDUIT FIXTURE WHIP WITH CONDUCTORS BRANCH CIRCUIT WIRING SHOWING CIRCUIT HOME RUN TO PANELBOARD. HASHMARKS SHOW QUANTITY OF CONDUCTORS WHEN MORE THAN THREE REQUIRED DOT INDICATES GROUND CONDUCTOR NEUTRAL CONDUCTOR SHOWN LARGER. PROVIDE DEDICATED NEUTRAL FOR EACH CIRCUIT. RACEWAY TURNING UP RACEWAY TURNING DOWN CIRCUIT CONTINUATION LOW VOLTAGE WIRING JUNCTION BOX PULL BOX RECEPTACLES Irm DUPLEX RECEPTACLE - NEMA 5 -15R (NEMA 5 -20R FOR DEDICATED CIRCUIT) PANELBOARD 120/208V OR 120/240V DUPLEX RECEPTACLE - ABOVE COUNTER. COORDINATE W/ ARCH. ELEVATIONS if GA DUPLEX RECEPTACLE - GROUND FAULT INTERRUPTING D DUPLEX RECEPTACLE - DEDICATED (NEMA 5 -20R) y� DUPLEX RECEPTACLE - COMPUTERS At DOUBLE DUPLEX RECEPTACLE ${, DOUBLE DUPLEX RECEPTACLE - COMPUTERS y{' DUPLEX RECEPTACLE - CEILING MOUNTED FVNR DOUBLE DUPLEX RECEPTACLE - CEILING MOUNTED, PROJECTORS EQUIPMENT CONNECTION EF_ -1-1 MECHANICAL EQUIPMENT CALLOUT. REFER TO MECHANICAL G DUPLEX RECEPTACLE - CEILING MOUNTED, PROJECTORS 4v ASV AIR SOLENOID VALVE GALV DOUBLE DUPLEX RECEPTACLE - MOUNT IN AV CABINET RETURN AIR FAN SPECIAL RECEPTACLE - TYPE AS INDICATED © CORD REEL —LV- m PB ELr-CTRICAL RISER GROUND CIRCUIT BREAKER NUMBER INDICATED TRIP SETTING AND NUMBER OF POLES PANELBOARD CURRENT TRANSFORMER (CT) CABLE TO BUS CONNECTION AUTOMATIC TRANSFER SWITCH (ATS) FEEDER TYPE - REFER TO FEEDER SCHEDULE ON ONE -LINE UTILITY METER POWER MONITOR WATTHOUR METER TVSS RACEWAYS RACEWAY CONCEALED IN WALL OR CEILING, EXPOSED IN UNFINISHED AREAS RACEWAY CONCEALED BELOW FLOOR FLEXIBLE CONDUIT FIXTURE WHIP WITH CONDUCTORS BRANCH CIRCUIT WIRING SHOWING CIRCUIT HOME RUN TO PANELBOARD. HASHMARKS SHOW QUANTITY OF CONDUCTORS WHEN MORE THAN THREE REQUIRED DOT INDICATES GROUND CONDUCTOR NEUTRAL CONDUCTOR SHOWN LARGER. PROVIDE DEDICATED NEUTRAL FOR EACH CIRCUIT. RACEWAY TURNING UP RACEWAY TURNING DOWN CIRCUIT CONTINUATION LOW VOLTAGE WIRING JUNCTION BOX PULL BOX EQUIPMENT Irm PANELBOARD 277/480V G PANELBOARD 120/208V OR 120/240V I-IP))�l CABINET - TYPE AS INDICATED ON PLAN ® SWITCHBOARD El STROBE ® TRANSFORMER - SIZE AND VOLTAGE AS INDICATED ON PLAN 0 HORSEPOWER RATED TOGGLE SWITCH WITH OVERLOAD PROTECTION Igt COMBINATION STARTER AIC HP RATED, 3 -POLE, NEMA 1 MINIMUM UNLESS NOTED FU or F OTHERWISE - OVERCURRENT PROTECTION AS REQUIRED E, NON -FUSED DISCONNECT SWITCH - SIZE PER CONNECTED LOAD IFh FUSED DISCONNECT SWITCH - SIZE PER CONNECTED LOAD. FVNR PROVIDE FUSES PER EQUIPMENT NAMEPLATE. ® EQUIPMENT CONNECTION EF_ -1-1 MECHANICAL EQUIPMENT CALLOUT. REFER TO MECHANICAL G EQUIPMENT SCHEDULE. —LV- m PB ELr-CTRICAL RISER GROUND CIRCUIT BREAKER NUMBER INDICATED TRIP SETTING AND NUMBER OF POLES PANELBOARD CURRENT TRANSFORMER (CT) CABLE TO BUS CONNECTION AUTOMATIC TRANSFER SWITCH (ATS) FEEDER TYPE - REFER TO FEEDER SCHEDULE ON ONE -LINE UTILITY METER POWER MONITOR WATTHOUR METER TVSS RACEWAYS RACEWAY CONCEALED IN WALL OR CEILING, EXPOSED IN UNFINISHED AREAS RACEWAY CONCEALED BELOW FLOOR FLEXIBLE CONDUIT FIXTURE WHIP WITH CONDUCTORS BRANCH CIRCUIT WIRING SHOWING CIRCUIT HOME RUN TO PANELBOARD. HASHMARKS SHOW QUANTITY OF CONDUCTORS WHEN MORE THAN THREE REQUIRED DOT INDICATES GROUND CONDUCTOR NEUTRAL CONDUCTOR SHOWN LARGER. PROVIDE DEDICATED NEUTRAL FOR EACH CIRCUIT. RACEWAY TURNING UP RACEWAY TURNING DOWN CIRCUIT CONTINUATION LOW VOLTAGE WIRING JUNCTION BOX PULL BOX ELECTRICAL ABBREVIATIONS AF SPECIAL SYSTEMS FACP DffLeau F[O MANUAL. PULL STATION WITH GUARD I-IP))�l HORN /STROBE ILSI< HORN /STROBE - CEILING MOUNT FM STROBE ® STROBE - CEILING MOUNT OSMOKE DETECTOR Q X MLE0NH0ICAIl u TELECOMMUNICATIONS OUTLET AIC X = QTY. OF CAT 6 JACKS ELECTRICAL ABBREVIATIONS AF AMPERE FRAME FACP FIRE ALARM CONTROL PANEL PROJ PROJECTOR AFF ABOVE FINISHED FLOOR FDMPR FIRE DAMPER PS PROJECTION SCREEN AHU AIR HANDLING UNIT FH FUME HOOD PTR PRINTER AIC AMPERE INTERRUPTING CURRENT FU or F FUSE PVC POLYVINYL CHLORIDE (PLASTIC) AMP AMPERE FVNR FULL VOLTAGE NON- REVERSING PWR POWER AS AMPERE SWITCH G GROUND QTY QUANTITY ASV AIR SOLENOID VALVE GALV GALVANIZED RA FAN RETURN AIR FAN AT AMPERE TRIP GC GOGGLE CABINET RECPT RECEPTACLE ATS AUTOMATIC TRANSFER SWITCH GO GARBAGE DISPOSAL REF REFRIGERATOR AWG AMERICAN WIRE GAUGE GEC GROUNDING ELECTRODE CONDUCTOR READ REQUIRED BAS BUILDING AUTOMATION SYSTEM GEN GENERATOR RH RANGE HOOD BBO BACKBOARD OPERATOR GFCI GROUND FAULT CIRCUIT INTERRUPTER RMC RIGID METALLIC CONDUIT BL BLEACHERS GRS GALVANIZED RIGID STEEL RING RANGE BLDG BUILDING GSV GAS SOLENOID VALVE RSD ROLLING STEEL DOOR C CONDUIT HH HAND HOLE SDMPR SMOKE DAMPER CAB CABINET HID HIGH INTENSITY DISCHARGE SF SUPPLY FAN CB CIRCUIT BREAKER HP HORSEPOWER SOLV SOLENOID VALVE CCTV CLOSED CIRCUIT TELEVISION HPF HIGH POWER FACTOR SPEC SPECIFICATION CKT CIRCUIT HIPS HIGH PRESSURE SODIUM SPST SINGLE POLE, SINGLE THROW CLG CEILING HT HEAT TRACE ST SHUNT TRIP CM COFFEE MAKER IF! INSTAHOT STD STANDARD CMU CONCRETE MASONRY UNIT IM ICE MACHINE STL STEEL CO CONDUIT ONLY IWO INTERCOM WALL DISPLAY SW SWITCH COMA COMMUNICATION J -BOX JUNCTION BOX SWBD SWITCHBOARD CT COOK TOP kcmil THOUSAND CIRCULAR MILS SWGR SWITCHGEAR CT CURRENT TRANSFORMER kV KILOVOLT TEL TELEPHONE CU COPPER kVA KILOVOLT AMPERE TEMP TEMPORARY DCVA DOUBLE CHECK VALVE ASSEMBLY kW KILOWATT TIP TRAP PRIMER DET DETAIL kWh KILOWATT HOUR TTB TELEPHONE TERMINAL BOARD DIA DIAMETER MAX MAXIMUM TVSS TRANSIENT VOLTAGE SURGE SUPPRESSION DISC DISCONNECT MCC MOTOR CONTROL CENTER TYP TYPICAL DSPL DISPOSAL MFR MANUFACTURER UC UNDER COUNTER DIN DOWN MECH MECHANICAL UGND UNDERGROUND DO DOOR OPERATOR MH MANHOLE; METAL HALIDE UH UNIT HEATER DPST DOUBLE POLE, SINGLE THROW MIN MINIMUM UL UNDERWRITERS LABORATORIES DRY DRYER ML MAGNETIC LOCK UON UNLESS OTHERWISE NOTED DIN DISHWASHER MLO MAIN LUGS ONLY UPS UNINTERRUPTIBLE POWER SUPPLY DWG DRAWING MTD MOUNTED V VOLT EA EACH MTG MOUNTING VA VOLT AMPERE EF EXHAUST FAN MW MICROWAVE VFD VARIABLE FREQUENCY DRIVE EH ELECTRIC HEATER NEC NATIONAL ELECTRICAL CODE VIA VENDING MACHINE EHD ELECTRIC HAND DRYER NEUT NEUTRAL W WATT ELEC ELECTRIC INC NORMALLY CLOSED W/ WITH ELEV ELEVATOR NIC NOT IN CONTRACT WAC WASHINGTON ADMINISTRATIVE CODE EMT ELECTRICAL METALLIC TUBING NO NUMBER; NORMALLY OPEN WAS WASHER EPO EMERGENCY POWER OFF NTS NOT TO SCALE W/D STACKED WASHER / DRYER EQUIP EQUIPMENT OD OVERHEAD (COILING) DOOR WF WASH FOUNTAIN EWC ELECTRIC WATER COOLER OF /CI OWNER FURNISHED / CONTRACTOR IMSTALLED WM WASHING MACHINE EWH ELECTRIC WATER HEATER OF /01 OWNER FURNISHED / OWNER INSTALLED W/0 WITHOUT EWS ELECTRIC WINDOW SHADE PF POWER FACTOR WON WON DOOR EXIST EXISTING PH or 0 PHASE MP WEATHERPROOF; WATERPROOFING FA FIRE ALARM PN POST INDICATOR VALVE XFMR TRANSFORMER FAAP FIRE ALARM ANNUNCIATOR PANEL PNL PANEL Z IMPEDANCE DEVICE MOUNTING HEIGHTS SPECIAL OUTLET HEIGHTS ARE SHOWN ON THE ELECTRICAL DRAWINGS OR ON THE ARCHITECTURAL DRAWINGS. IF SPECIAL OUTLET HEIGHTS ARE NOT SHOWN OR REQUIRED, THEN LOCATE OUTLETS AS NOTED BELOW. OUTLET HEIGHTS ARE MEASURED FROM THE FINISHED FLOOR TO THE CENTERLINE OF THE OUTLET UNLESS OTHERWISE NOTED. RECEPTACLES 18 INCHES VERITCALLY MOUNTED EO.02 LIGHT SWITCHES 48 INCHES VERTICALLY MOUNTED PANELBOARDS '72 INCHES TO TOP OF PANELBOARD E2.11 UGHTING PLAN - FIRST FLOOR TELEPHONE OUTLET - DESK 18 INCHES VERTICALLY MOUNTED TELEPHONE OUTLET - WALL 54 INCHES VERTICALLY MOUNTED COMPUTER OUTLET - DESK 18 INCHES VERTICALLY MOUNTED FIRE ALARM PULL STATION 48 INCHES INTERCOM CALL BUTTON 48 INCHES DIGITAL CLOCK /SPEAKER PER ARCHITECTURAL INTERIOR ELEVATIONS ANALOG CLOCK PER ARCHITECTURAL INTERIOR ELEVATIONS CAN OUTLET 18 INCHES VERTICALLY MOUNTED KEYPAD /CARD READER 48 INCHES FIRE ALARM HORN, STROBE OR I HORN /STROBE NOT LESS THAN 80" OR GREATER THAN 96" TO THE BOTTOM FIRE ALARM CONTROL PANEL 72 INCHES DOOR OPERATOR PUSH BUTTON 48 INCHES OR AS SHOWN ON ARCHITECTURAL ELEVATIONS E4.11 SYSTEMS PLAN - FIRST FLOOR E5.11 ONE -LINE DIAGRAM E6.11 PANEL SCHEDULES colm t 425.778.1530 21911 76th Ave W. Suite 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com ACOFFMAN N G I N E E R S 1601 Fifth Avenue, Suite 900 Seattle, WA 98101 -1625 ph 206.623.0717 fax 206.624.3775 coffman.com LASTING aeativity 1 results I relationships YELM MOB TENANT IMPROVEMENTS 201 TAHOMA BLVD SE YELM, WA 98597 COVER SHEET AND GENERAL INFORMATION ISSUANCE CONSTRUCTION DOCUMENTS 02/0812013 PROJECT INFORMATION _ CEI. PROJECT NO: _ _ 13107 PROJECT MANAGER' JGJ DRAWN BY LEN SHEET NO E0.01 DRAW_ ING INDEX T NUMBER - DESCRIPTION EO.01 COVER SHEET AND GENERAL INFORMATION EO.02 GENERAL NOTES EO.03 SPECIFICATIONS & LUMINAIRE SCHEDULE E2.11 UGHTING PLAN - FIRST FLOOR E3.11 POWER PLAN - FIRST FLOOR E3.12 ENLARGED PLANS & DETAILS E3.13 ENLARGED PLANS & DETAILS E3.14 ENLARGED PLANS & DETAILS E4.11 SYSTEMS PLAN - FIRST FLOOR E5.11 ONE -LINE DIAGRAM E6.11 PANEL SCHEDULES colm t 425.778.1530 21911 76th Ave W. Suite 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com ACOFFMAN N G I N E E R S 1601 Fifth Avenue, Suite 900 Seattle, WA 98101 -1625 ph 206.623.0717 fax 206.624.3775 coffman.com LASTING aeativity 1 results I relationships YELM MOB TENANT IMPROVEMENTS 201 TAHOMA BLVD SE YELM, WA 98597 COVER SHEET AND GENERAL INFORMATION ISSUANCE CONSTRUCTION DOCUMENTS 02/0812013 PROJECT INFORMATION _ CEI. PROJECT NO: _ _ 13107 PROJECT MANAGER' JGJ DRAWN BY LEN SHEET NO E0.01 GENERALNOTES THE FOLLOWING GENERAL NOTES APPLY TO ALL DRAWINGS 1. ITEMS NOTED AS "TYPICAL" ON ANY DRAWING REFERS TO ALL DRAWINGS. 2. PROVIDE NYLON PULL STRING IN ALL EMPTY RACEWAYS. 3. NO STRUCTURAL MEMBERS SHALL BE CUT OR ALTERED WITHOUT PRIOR APPROVAL OF THE ARCHITECT AND STRUCTURAL ENGINEER. 4. ALL RACEWAYS WITHIN THE BUILDING SHALL BE RUN OVERHEAD U.O.N. RACEWAYS SHALL NOT BE RUN UNDER THE FLOOR SLAB UNLESS SPECIFICALLY SHOWN ON THE DRAWINGS. 5. LOCATIONS OF ALL WALL MOUNTED DEVICES ARE SHOWN SCHEMATICALLY. COORDINATE WITH THE ARCHITECTURAL DRAWINGS, ELEVATIONS AND CASEWORK SUPPLIERS SHOP DRAWINGS FOR EXACT LOCATION OF DEVICES PRIOR TO ROUGH -IN. 6. ALL RACEWAYS IN FINISHED SPACES SHALL BE CONCEALED. 7. SEAL ALL PENETRATIONS IN RATED FLOORS AND CEILINGS WITH A UL APPROVED FIRE STOP SYSTEM. B. PROVIDE A COMPLETE DESIGN -BUILD PATHWAY SYSTEM FOR ALL SPECIAL SYSTEMS WIRING, SEE SPECIFICATIONS. QUANTITY AND SIZE OF RACEWAYS SHOWN ON SPECIAL SYSTEMS PLANS ARE THE MINIMUM TO BE PROVIDED. CONTRACTOR SHALL PROVIDE ALL RACEWAYS AS REQUIRED. 9. ALL LOW VOLTAGE WIRING NOT RUN IN A METALLIC RACEWAY SHALL BE PLENUM RATED. 10. ALL EQUIPMENT, LUMINAIRES, RACEWAYS, DEVICES, ETC. SHALL BE UL USTED. 11. MOUNT ALL DEVICES ABOVE COUNTERS 6" ABOVE BACKSPIASH UNLESS NOTED OTHERWISE. 12. WHERE A CONFLICT EXISTS THE MOST EXPENSIVE OPTION SHALL GOVERN. DOOR HARDWARE 1. PROVIDE ALL RACEWAYS AND WIRING REQUIRED TO INSTALL ELECTRONIC DOOR HARDWARE. REFER TO DOOR HARDWARE SPECIFICATIONS, SCHEDULES AND DIAGRAMS. LIGHTING PLANS THE FOLLOWING GENERAL NOTES APPLY TO ALL LIGHTING PLAN DRAWINGS 1. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF LUMINAIRES. 2. REFER TO ARCHITECTURAL ELEVATIONS FOR EXACT LOCATIONS OF EXTERIOR LUMINAIRES. 3. COORDINATE THE FINAL LOCATION OF LUMINAIRES IN MECHANICAL ROOMS AND ATTIC SPACES TO AVOID CONFLICTS WITH DUCT WORK, PIPING, AND MECHANICAL EQUIPMENT. 4. ROUTE ALL EXTERIOR UGHTING CIRCUITS VIA UGHTING CONTROL PANEL. 5. INSTALL AND WIRE REMOTE BALLASTS AND DRIVERS. REFER TO LUMINAIRE SCHEDULE. MOUNT IN ACCESSIBLE LOCATIONS. SHOW LOCATIONS ON THE AS -BUILT DRAWINGS. POWER PLANS THE FOLLOWING GENERAL NOTES APPLY TO ALL POWER PLAN DRAWINGS 1. CIRCUIT ALL FIRE /SMOKE DAMPERS AND SMOKE DAMPERS FROM NEAREST 120V EMERGENCY PANEL WITH %'- 3.812. UTILIZE SPARE 20A -1P BREAKER PROVIDED. RECORD CIRCUh1NG ON AS -BUILT DRAWINGS. REFER TO MECHANICAL DRAWINGS FOR DAMPER LOCATIONS. 2. COORDINATE LOCATIONS OF BAS CONTROL POWER WITH THE CONTROLS CONTRACTOR PRIOR TO ROUGH -IN. 3. PRIOR TO ORDERING EQUIPMENT OR ROUGH -IN, COORDINATE WITH THE MECHANICAL CONTRACTOR TO ESTABLISH THE ACTUAL LOAD AND OVERCURRENT PROTECTION REQUIREMENTS FOR EACH PIECE OF EQUIPMENT. 4. REFER TO MECHANICAL EQUIPMENT CONNECTION SCHEDULE FOR EQUIPMENT RATINGS AND FEEDER SIZES. 5. PROVIDE DISCONNECT SWITCH OR COMBINATION STARTER FOR EACH PIECE OF EQUIPMENT AS SHOWN ON MECHANICAL EQUIPMENT CONNECTION SCHEDULE. 6. PRIOR TO ROUGH -IN OF ALL EQUIPMENT SPECIFIED BY OTHER DIVISIONS, COORDINATE WITH THE EQUIPMENT MANUFACTURER TO ESTABLISH ALL REQUIREMENTS FOR EACH PIECE OF EQUIPMENT. 7. FEEDER ROUTING SHOWN IS APPROXIMATE. COORDINATE WITH MECHANICAL SYSTEMS AND BUILDING STRUCTURE. PROVIDE OFFSETS AS REQUIRED. 8. ALL RECEPTACLES WITHIN 6 FEET OF A SINK SHALL BE GFI TYPE. UIPMENT CONNECTIONS 1. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER SHOP DRAWINGS PRIOR TO ROUGH -IN. 2. INSTALL AND WIRE EQUIPMENT PER MANUFACTURER SHOP DRAWINGS. 3. PROVIDE ALL RACEWAYS, WIRING AND ANCILLARY EQUIPMENT AS SHOWN ON MANUFACTURER SHOP DRAWINGS. 4. PROVIDE HARDWIRED CONNECTION, RECEPTACLE OR FUSED DISCONNECT SWITCH AS SHOWN ON MANUFACTURER SHOP DRAWINGS. SYSTEMS PLANS 10. FAT/ 714LIJI1IeIH021q :IInIb113'L1JywaU1_1IRMW( LIW]671AS6V�w:L0r1. ;iIlNliY 1. MINIMUM RACEWAY SIZE SHALL BE 1" FOR TELECOMMUNICATIONS CABLING AND Y4" FOR ALL OTHER SYSTEMS. 2. ALL SPECIAL SYSTEMS WIRING EXCEPT FIRE ALARM SHALL BE RUN UTILIZING OPEN WIRING METHOD ABOVE ACCESSIBLE CEILINGS. PROVIDE METALLIC RACEWAYS FOR WIRING INSTALLED IN WALLS, ABOVE INACCESSIBLE CEILING, WHERE EXPOSED OR WHERE SUBJECT TO PHYSICAL DAMAGE. RACEWAY FILL SHALL NOT EXCEED 40%. _BRANCH CIRCUIT WIRING THE FOLLOWING GENERAL NOTES APPLY TO ALL DRAWINGS 1. IN GENERAL ONLY CIRCUIT NUMBERS HAVE BEEN SHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL PROVIDE ALL REQUIRED RACEWAYS AND WIRING. 2. SHOW ALL RACEWAYS AND WIRING ON AS -BUILT DRAWINGS. 3. GENERAL, 3,1. MINIMUM RACEWAY SIZE SHALL BE 314". 3.2. NO MORE THAN 7 #12 AWG CONDUCTORS SHALL BE INSTALLED IN A RACEWAY. 3.3. HOMERUNS GREATER THAN 75 FEET TO THE FIRST DEVICE SHALL BE NO. 10 AWG. 3.4. UGHTING, POWER, AND MECHANICAL EQUIPMENT CONDUCTORS SHALL NOT BE COMBINED IN THE SAME RACEWAY. 3.5. PROVIDE A GROUND CONDUCTOR IN ALL RACEWAYS. 3.6. PROWDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT. 4. LIGHTING: 4.1. PROVIDE CONDUCTORS AS REQUIRED TO PROVIDE CIRCUMNG AND SWITCHING DUTY AS SHOWN ON THE DRAWINGS. 4.2. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT. 5. POWER: 5.1. PROVIDE CONDUCTORS AS REQUIRED TO PROVIDE CIRCUITING SHOWN. 5.2. FOR OTHER THAN 15 OR 20 AMP SINGLE PHASE RECEPTACLE BRANCH CIRCUITS PROVIDE A DEDICATED HOMERUN TO THE PANEL. 5.3. FOR 30 AMP BRANCH CIRCUITS PROVIDE #10 AWG CONDUCTORS. 5.4. FOR 40 AMP AND LARGER BRANCH CIRCUITS PROVIDE RACEWAYS AND WIRING AS SHOWN ON THE DRAWINGS. 5.5. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT. 6. MECHANICAL EQUIPMENT: PROVIDE RACEWAYS AND WIRING AS SHOWN ON THE MECHANICAL EQUIPMENT CONNECTION SCHEDULE. IWASHINGTON STATE NONRESIDENTIAL ENERGY CODE COMPLIANCE 1. LIGHTING: THE CONTRACTOR SHALL PROVIDE A WRITTEN CERTIFICATION VERIFYING THAT ALL LAMPS AND BALLASTS HAVE BEEN PROVIDED PER THE SPECIFICATIONS. PROVIDE A LIST WHICH INDICATES THE EXACT PART NUMBER OF THE LAMP AND BALLAST PROVIDED FOR EACH FIXTURE TYPE. INCLUDE THE CERTIFICATION AND THE LAMP /BALLAST LIST IN THE 0 &M MANUAL. 2. COMMISSIONING REQUIREMENTS: ALL UGHTING CONTROLS INCLUDING DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS, AUTOMATIC SHUT OFF CONTROLS, OCCUPANCY SENSORS OR AUTOMATIC TIME SWITCHES, THE LIGHTING CONTROLS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. SEQUENCE OF OPERATIONS SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. THE CONTRACTOR SHALL PROVIDE A WRITTEN STATEMENT CERTIFYING ALL LIGHTING CONTROLS HAVE BEEN COMMISSIONED. INCLUDE CERTIFICATION IN 0 &M MANUAL. ME t 425.778.1530 21911 76th Ave W. Suite 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com ,&COFFMAN N G I N E E R S 1601 Fifth Avenue, Suite 900 Seattle, WA 98101 -1625 ph 206.623.0717 fax 206.624.3775 coffman.com LASTING creativity I results I relationships YELM MOB TENANT IMPROVEMENTS 201 TAHOMA BLVD SE YELM, WA 98597 GENERAL NOTES ISSUANCE CONSTRUCTION DOCUMENTS 02/08/2013 PROJECT INFORMATION CEI PROJECT NO: PROJECT MANAGER: DRAWN BY: SHEET NO E0.02 13107 JGJ LEN ELECTRICAL SPECIFICATIONS ELECTRICAL, GENERAL PROVISIONS A SCOPE OF WORK 1. Provide all labor and material necessary to accomplish the work specified herein and as shown on the drawings. 2. Coordinate work with all other trades. 3. Visit the site and verify existing conditions prior to submitting bid. 4. Remove all waste and rubbish from the site on a daily basis. 5. The existing fire alarm system must remain in operation at all times. Provide a "fire watch" anytime the existing fire alarm is taken out of service. B. WARRANTY: Workmanship and materials shall be guaranteed for a period of one year from the date of final acceptance by the Owner. C. REGULATIONS 1. Electrical work shall comply with the following codes as presently applicable: a. National Electrical Code (NEC) b. Washington State Non - Residential Energy Code (NREC) c. Washington Administrative Code (WAC) d. Local and State codes and regulations 2. Permits: Obtain and pay for all required permits. 3. Safety Measures: Provide a safe environment to protect employees and oil others from injury. Comply with "Safety and Health Regulations for Construction; Volume 36, No. 75, Part II, of the Federal Register by the U.S. Department of Labor. D. SUBMITTAL AND SHOP DRAWINGS: Prior to installation, submit catalog data for all equipment and materials for review. Submit shop drawings showing complete terminal -to- terminal wiring for each special system. Three copies required. E. OPERATIONS AND MAINTENANCE MANUALS: Provide maintenance and operations data for all electrical equipment and special systems. Three copies are required. F. RECORD DRAWINGS: Corrections and changes made during the progress of the work shall be neatly recorded as actually installed for as -built records. Submit to the Owner upon project completion. G. CERTIFICATES OF INSPECTION: Submit signed -off permits from the Code Enforcing Agencies to the Owner upon project completion. H. PRODUCT LISTING OR LABELING: All electrical equipment shall be listed and labeled by Underwriters' Laboratories, Inc. I. MATERIAL AND EQUIPMENT: All materials and equipment shall be new unless noted otherwise. Protect all materials and equipment from damage or corrosion. J. CUTTING AND PATCHING: Provide all required cutting and patching for the electrical work. K. REMOVAL AND REPLACEMENT OF EXISTING ACCESSIBLE CEILING PANELS, LIGHTING FIXTURES AND SPEAKERS: Remove and reinstall all necessary ceiling panels, lighting fixtures, speakers and other existing equipment in existing accessible ceilings as required to install the electrical work. L ANCHORAGE AND BRACING: Provide complete seismic anchorage and bracing for the lateral and vertical support of conduit and electrical equipment as required by the Uniform Building Code. M. FlRESTOPPING: Provide firestopping for all penetration in rated walls, ceilings and floors. N. PAINTING: Paint all exposed raceways, except SMR, in finished areas to match adjacent surfaces. 0. INSTRUCTION: Contractor shall instruct the Owner in the use and operation of all systems installed under the scope of this contract. BASIC MATERIALS AND METHODS A. RACEWAYS AND FITTINGS 1. Raceways: a. Rigid Metallic Conduit: Zinc - coated steel with full threaded connections. b. Electrical Metallic Tubing (EMT): Zinc - coated steel. c. Rigid Nonmetallic Conduit: Rigid PVC, Schedule 40, UL listed for direct burial or concrete encasement. d. Flexible Metallic Conduit: Galvanized steel, securely interlocked. 2. Fittings: a. Rigid Metallic Conduit: 1) Couplings: Threaded metallic type of the some material as the conduit. 2) Locknuts: Steel up to 2 inches, malleable iron for 2 -1/2 inches and larger. 3) Bushings: Bakelite or plastic up to 2 inches, malleable iron with insulating collar for 2 -1/2 inches and larger. 4) Unions: Zinc plated malleable iron, 3 piece conduit coupling. a. Electrical Metallic Tubing (EMT): 1 -1/2" and smaller shall be mintight type steel employing a split corrugated ring and tightening nut. Fittings 2" and larger shall be steel and may be setscrew type containing dual setscrews on each side of coupling. b. Rigid Nonmetallic Conduit: Slip -on, nonthreaded type of some material as conduit. c. Flexible Metallic Conduit: Steel, one- or two -screw clamp type. 3. Conduit Straps: Heavy duty, two -hole pressed steel. B. 600 -VOLT WIRE AND CABLE 1. Feeders: Type THHN/THWN 600 -volt insulation, copper conductor, stranded. 2. Branch Circuits: Type THHN/THWN, 600 -volt insulation, copper conductor, stranded. Minimum size shall be No. 12 AWG for phase and ground conductors and No. 10 AWG for neutral conductors. C. OUTLET, JUNCTION AND PULL BOXES 1. Outlet and Device Boxes: a. Interior Surface- Mounted ih Unfinished Areas: One -piece pressed steel, electro- galvanized, size and depth required by Code, except 4 -inch square or 4 -inch octagonal minimum. b. Interior Flush - Mounted: Some as above except provide plaster ring extension to finished surface. c. Interior Surface - Mounted, Finished Areas: Wiremold No. 5700 Series sized to fit standard wiring device and for fire alarm devices provide boxes with a factory applied red finish (special order product). Verify device box requirements with the fire alarm supplier. 2. Junction and Pull Boxes: a. Interior Areas: Steel, screw cover, code gauge and size. Large junction and pull boxes shall be fabricated sheet steel with baked enamel finish and return flange with screw retained cover. b. Exterior. Cast, non- ferro4s metal with cast, gasketted covers; or sheet steel, hot -dip galvanized after fabrication, no KO's, with gasketted screw cover. D. WIRING DEVICES 1. Approved Manufacturers: F3ryont, Cooper Wiring Devices (Arrow hart), Hubbell, P & S or Leviton. All part numbers refer to Hubbell 2. Color of Switch Handles aNd Receptacle Faces: Ivory. 3. Receptacles: a. Duplex Receptacles: Specification- grade, except hospital grade in all patient care areas, 15 ampere, 125 volt grounded type, 5262 series. b. Dedicated Duplex Receptacles: Specification- grade, except hospital grade in all patient care areas, 20- ampere, 125 -volt grounded, 5362 series. c. Ground Fault Interruption Receptacle: Specification - grade, 20 ampere, 120 volts, Class A, 5- milliampere sensitivity, GF521 2 series. 4. Switches: a. Single -Pole Switches: Specification- grade, 20 ampere, 1221 series. b. Three -Way Switches: Specification- grade, 20 ampere, 1223 series. E. DEVICE PLATES: Satin fini4h stainless steel. Pass and Seymour /Sierra 302 "S" line or equal. F. VAULTS: Precast 30" long x 30" wide x 24" deep with an H -20 traffic -rated lid (full 18T open) and locking latch. Utility Vault Company 3030LA series with 3030 -B base and 3030 -P cover. Set on 36" deep grovel base. G. EXECUTION 1. General: a. Coordination: The Contractor shall review all drawings, details and elevations prior to rough -in. Where equipment is furnished by others, the Contractor shall ascertain the proper voltage, load and connection requirements prior to rough -in, b. Materials: All materials of a specific type shall be provided by the same manufacturer throughout the project. 2. Raceways: a. Raceway Types: Install roc;eway types and sizes as listed below: 1) Electrical Metallic Tubing (EMT): All areas other than above. May be used for feeders with integral green ground conductor. 2) Rigid Nonmetallic Conduit: Exterior underground installations; direct buried for lighting raceways. 90 degree elbows to be galvanized rigid steel. 3) Flexible Metallic Conduit: (Recessed fixture connections, interior concealed equipment connections, expansion joints and sound corltrol. Not to be used exposed installations within the building. a. Installation: 1) Concealment: All raceways; shall be concealed in finished areas. Where existing wall surfaces are inaccessible, surface metal raceways for these exceptions may be provided when approved. 2) Routing: All raceways shall be installed parallel or at right angles to the building construction unless prohibited by a physical obstruction. 3) Raceway Supports: Raceways shall be supported with heavy -duty, one -hole, pressed steel straps on interior surfaces. Support pendant- mounted raceways on 3/8 -inch rod with pear- shaped hanger or tropeze -type hanger with 3/8- -inch rod (minimum) and 1 -5/8 -inch square preformed channel and pipe clamps. Parallel, surface - mounted raceways shall be supported from 1 -5/8 -inch square preformed channel and pipe clamps. All fittings and supports shall be hot -dip galvanized in exterior areas. 4) Independent Support: Conduits shall not be supported from the ceiling suspension system, ducts, pipes or other systems foreign to the electrical installation. The entire electrical installation shall be kept independent from any other trade. 5) Puliboxes with Covers: Shall be provided as shown on the drawings or as required by Code. Al pullboxes shall be located so as to be accessible. 6) Flexible Conduit: Shall be used only for lighting fixture pigtails in accessible ceilings, flush - mounted speaker pigtails in accessible ceilings, sound control, motor connections and at building expansion joints as specified. Any other proposed use of flexible conduit must be approved prior to installation. 7) Penetrations: Raceways which pass through building roof, exterior walls of building above or below grade and floor slabs on grade, shall be sealed on the interior side of the building using non - hardening sealing compound after all conductors have been installed in the raceway. Sealing material shall be specifically designed for electrical wiring systems. 8) Conduit Passing Through Building Roof: Provide a 4 lb. lead plumbing vent flashing with a counterflashing attached above using a galvanized steel clamp. 8) Conduit Penetrating Membirones: All conduits penetrating walls or slabs with membranes shall be installed with approved membrane clamping devices in order to provide necessary seal. 10) Empty Raceways: Provide a nylon pull string in all empty raceways. 3. Wire and Cable: a. Branch Circuits: Branch circuits shall be No. 12 AWG minimum, color -coded as listed below. Homeruns greater than 75 feet to first outlet shall be No. 10 minimum. b. Feeders: Feeders shall be sized as shown on the drawings and color -coded in accordance with list below. Make no splices unless shown on the plans. c. Color Coding Requirements: 1) 120/208 Volt, 3- Phase, 4 -Wire Systems: Phase A: Black Phase B: Red Phase C: Blue Neutral: White Ground: Green Travelers: Yellow (for 3- and 4 -way switching) Controls: Black with wire numbers on each conductor 2) 277/480 Volt, 3- Phase, 3 and 4 -Wire Systems: Phase A. Brown Phase B: Orange Phase C: Yellow Neutral: Gray Ground: Green Travelers: Lavender d. Splices and Terminations: Lighting and receptacle branch circuit conductors up to No. 10 AWG shall be spliced with Wing Nut type connectors. e. Home Runs: Branch circuit conductors shall be home run to panelboards or motor control centers in groupings as shown on the drawings. Combining branch circuit home run conductors in single conduits other than that shown, will not be permitted. 4. Boxes and Fittings: a. General: Boxes shall be supported securely and independently. Mount boxes on building surfaces or support with trapeze hanger as described in Raceway Installation. Junction boxes shall not be used unless the number of bends, pulling length, or circuit requirements necessitates their installation. Junction or pullbox openings must be accessible. b. Sound Control: Where boxes are mounted in a common wall, they shall wherever possible, be offset horizontally so that they are not mounted back -to -back. Connect offset boxes with flexible conduit not to exceed 18 inches in length. 5. Wiring Devices: a. General: Install devices level, plumb and square with building lines. b. Switch Locations: Locate switches 6 inches from door casing. c. Mounting Heights: Height of devices to the center line of the box sholl be as follows unless otherwise noted. Switch: +48" Receptacle: +18" Above Counter Receptacles: Bottom of box to be 1" above backsplash or counter. 6. Grounding: a. General: Provide through the entire electrical system. A separate green equipment grounding conductor shall be provided in all lighting and power raceways. b. Bonding: Insulated grounding bushings shall be installed to bond all feeder conduits to the switchboard ground bus or panel ground bus at both ends of feeder raceways. Insulated grounding bushings shall be installed to bond all feeder conduits to the ground bus or panel enclosures at both ends of the runs. c. Receptacle Grounding: Connect the ground terminal of all receptacles by utilizing a separate grounding conductor between the receptacle grounding screw and the ground conductor provided in the branch circuit. Integral mounting straps within the receptacle connected to the device mounting straps are not approved as a grounding method. d. Flexible Conduit Grounding: Provide a separate grounding conductor in all flexible conduit runs including watertight flexible conduit with integral grounding straps. Install ground conductor inside conduit with ungrounded conductors. 8. Owner- Furnished Equipment: Provide complete electrical service and connection to all Owner - furnished equipment. 9. Identification: In general, label all junction boxes, terminal cabinets, etc., with the circuit number or low- voltage system contained within. The fire alarm junction boxes shall be painted red. DISTRIBUTION EQUIPMENT A. DISCONNECT SWITCHES 1. Approved Manufactures: General Electric, Siemens or Square D. 2. Single -Phase Motor. Motors 1/3 HP or less provide with toggle -type, 20 -amp, 120 -volt rating, specification -grade disconnect switches. 3. Three -Phase Motor: Motors 1/2 HP and larger provide with horsepower- rated, heavy -duty, 30 ampere minimum, 3 -pole disconnect switches. 4. Equipment Disconnects: Shall be fused or nonfused as required by the equipment manufacturer, rated at 125% of full load nameplate amperage or rated horsepower, heavy -duty type. B. FUSES 1. Approved Manufactures: Bussman, Ferrez Shawmut or Uttlefuse. 2. Provide 200,0 -00 AIC, current limiting, UL time delay fuses as follows: a. For feeders 601 -6000 amps: Class 4 KRP -C Time Delay. b. For feeders 600 amps and less: Class RK -1, LPN -RK for 250 -volt, dual element; Class RK -1, LPS -RK for 600 -volt, dual element; 12. ALL METAL HALIDE LAMPS /BALLASTS SHALL BE PULSE START. 13. PROVIDE GLARE SHIELDS FOR ALL POLE MOUNTED LUMINAIRE. 14. THE CONTRACTOR SHALL REVIEW THE ARCHITECTURAL INTERIOR ELEVATIONS AND THE CASEWORK MANUFACTURER SHOP DRAWINGS TO DETERMINE THE LENGTH OF UNDER COUNTER LIGHT LUMINAIRE. 15. REFER TO ARCHITECTURAL ELEVATIONS TO DETERMINE PENDANT LENGTH. 16. REFER TO THE SPECIFICATIONS AND DRAWINGS FOR ADDITIONAL REQUIREMENTS. 17. AIM ADJUSTABLE LUMINAIRES AS DIRECTED BY THE ENGINEER. SUBSTITUTIONS 1, NO POST BID SUBSTITUTIONS WILL BE CONSIDERED. 2. WHERE ONLY ONE MANUFACTURER IS LISTED, PRE -BID SUBSTITUTIONS WILL ONLY BE CONSIDERED IF A SAMPLE OF THE FIXTURE IS PROVIDED. c. For motor circuit 600 volts and below: Class RK -1 or Class J sized at 125% FLC of motor. C. EXECUTION 1. Existing Ponelboards: Provide new branch circuit breakers, including associated mounting hardware, to serve new loads. 2. Disconnects: a. General: Provide disconnects at all motors and other equipment items unless the equipment has a self- contained, Corte approved disconnecting method. Equipment disconnects shall be fused or non -fused as required by the Equipment manufacturer. b. Mounting: Coordinate mounting location with Equipment Installation Contractor and Architect. In general, mounting height to be 6'0" maximum above floor. Mount on equipment framing or provide independent support system consisting of 1 -5/8 -inch square preformed channels minimum. SPECIAL SYSTEMS A GENERAL 1. All special cabling, except fire alarm, shall be plenum -rated and run exposed in cable trays. 2. Provide metallic raceways for cables installed in walls, above inaccessible ceilings, exposed or where subject to physical damage. Raceway fill shall not exceed 40 %. 3. Equipment and wiring shown on the drawings and specified herein is to assist the Contractor in preparing his bid. Additional equipment and wiring may be required. Contractor shall provide all equipment and wiring as determined by the equipment manufacturer. Submittal shall include raceway and wiring layout. 4. Mounting Heights of devices to the centerline of the box shall be as follows unless noted otherwise: a. Fire Alarm Pull Station : +48" b. Fire alarm Hom /Strobe: Not less than 80" or greater than 96" to the bottom. c. Communicatione Outlet: +18" d. Wall- Mounted Communications Outlet: +48" B. FIRE ALARM SYSTEM 1. Scope: Provide and install all equipment and wiring necessary to expand the existing fire alarm system. 2. Manufacturer. 3. Equipment: a. Hom /Strobe: To match site standard. b. Pull Station: lfo match site standard. c. Remote Annunciator: Replace existing graphic to show new portables. 4. Wiring: Any underground wiring must be direct - burial rated and UL listed for fire alarm service. 5. Provide complete wiring from the existing fire alarm panel to all portable classrooms. END OF ELECTRICAL SPECIFICATION t 425.778.1530 2191176th Ave W. Suite 210 f 425.774.7803 Edmonds WA98026 info@tgbarchitects.com www.tgbarchitects.com ACOFFMAN N G I N E E R S 1601 Fifth Avenue, Suite 900 Seattle, WA 98101 -1625 ph 206.623.0717 fax 206.624.3775 coffman.com LASTING creativity l results l relationships YELM MOB TENANT IMPROVEMENTS 201 TAHOMA BLVD SE YELM, WA 98597 SPECIFICATIONS & LUMINAIRE SCHEDULE ISSUANCE CONSTRUCTION DOCUMENTS 02/08/2013 _PROJECT INFORMATION CEI PROJECT NO _ PROJECT MANAGER: DRAWN BY: SHEET NO E0.03 13107 JGJ LEN GENERALNOTES LUMINAIRE SCSCHEDULE 1. THE UNDERLINED LUMINAIRE IN THE SCHEDULE Type Description Lamp Type WATTS/VA Manufacturer Information Schedule REPRESENTS THE "BASIS OF DESIGN ". ALL OTHER Notes MANUFACTURERS USTED MUST MEET OR EXCEED RFA7 EXISTING RECESSED 2'X4' FLUORESCENT LUMINAIRE ALL REQUIREMENTS OF THE BASIS OF DESIGN. (3) F32W 48T8 82/80 2. VERIFY THE VOLTAGE OF ALL LUMINAIRES. REFER TO PLANS FOR SPECIFIC VOLTAGE REQUIREMENTS. RF.B1 RECESSED COMPACT FLUORESCENT 6" DOWNUGHT 3. ALL LUMINAIRES TO BE PROVIDED WITH ALL 20 GAUGE GALVANIZED STEEL HOUSING, .050" ALUMINUM ONE PIECE SELF FLANGED CLEAR SEMI SPECULAR REFLECTOR, (1) 32W CFTR 35/60 OMEGA "SPEX S6" SERIES 1 ROUGH -IN AND TRIM ASSEMBLES FOR A COMPLETE DIMMING BALLAST INSTALLATION. 4. ALL LUMINAIRES TO BE PROVIDED WITH A CUSTOM GENERAL NOTES: COLOR /FINISH AS SELECTED BY THE ARCHITECT, UNLESS OTHERWISE NOTED. A REFER TO SHEET E003 FOR LUMINAIRE GENERAL NOTES. 5. ALL LUMINAIRES TO BE UL LISTED AND LABELED. B. T8 LAMPS BASED ON SYLVANIA ECOLOGIC XPS SERIES WITH 3100 INITIAL LUMEN OUTPUT EXTERIOR LUMINAIRES TO BE UL "WET" (LABELED. C. T8 BALLAST BASED ON SYLVANIA PROSTART PSN SERIES WITH 0.88 BALLAST FACTOR 6. LUMINIARES SHALL BE PROVIDED WITH AN INTERNAL SCHEDULE NOTES: DISCONNECTING MEANS WHICH COMPLIES WITH NEC ARTICLE 410. 1. PROVIDE 1 LAMP DIMMING BALLAST. 7. ALL FLUORESCENT AND HID BALLASTS TO BE PROVIDED WITH AN IN -LINE FUSE. B. ALL LUMINAIRES TO HAVE AN INTEGRAL BALLAST UNLESS A REMOTE BALLAST IS SPECIFIED. 9. TANDEM OR THROUGH -WIRED BALLASTS ARE NOT ALLOWED. PROVIDE A SEPARATE BALLACT FOR EVERY 4' LUMINAIRE 'SECTION'. 10. PROVIDE WIRE GUARDS AND PLASTIC LAMP SLEEVES FOR ALL FLUORESCENT LINEAR STRIP LUMINAIRES. 11. FOR HID LUMINAIRES FED FROM THE GENERATOR PROVIDE QUARTZ RESTRIKE WITH STANDBY TIME DELAY PER UL 1598. QUARTZ LAMP IS KEPT ON UNTIL THE HID LAMP REACHES 80% OF FULL LIGHT OUTPUT. ELECTRICAL SPECIFICATIONS ELECTRICAL, GENERAL PROVISIONS A SCOPE OF WORK 1. Provide all labor and material necessary to accomplish the work specified herein and as shown on the drawings. 2. Coordinate work with all other trades. 3. Visit the site and verify existing conditions prior to submitting bid. 4. Remove all waste and rubbish from the site on a daily basis. 5. The existing fire alarm system must remain in operation at all times. Provide a "fire watch" anytime the existing fire alarm is taken out of service. B. WARRANTY: Workmanship and materials shall be guaranteed for a period of one year from the date of final acceptance by the Owner. C. REGULATIONS 1. Electrical work shall comply with the following codes as presently applicable: a. National Electrical Code (NEC) b. Washington State Non - Residential Energy Code (NREC) c. Washington Administrative Code (WAC) d. Local and State codes and regulations 2. Permits: Obtain and pay for all required permits. 3. Safety Measures: Provide a safe environment to protect employees and oil others from injury. Comply with "Safety and Health Regulations for Construction; Volume 36, No. 75, Part II, of the Federal Register by the U.S. Department of Labor. D. SUBMITTAL AND SHOP DRAWINGS: Prior to installation, submit catalog data for all equipment and materials for review. Submit shop drawings showing complete terminal -to- terminal wiring for each special system. Three copies required. E. OPERATIONS AND MAINTENANCE MANUALS: Provide maintenance and operations data for all electrical equipment and special systems. Three copies are required. F. RECORD DRAWINGS: Corrections and changes made during the progress of the work shall be neatly recorded as actually installed for as -built records. Submit to the Owner upon project completion. G. CERTIFICATES OF INSPECTION: Submit signed -off permits from the Code Enforcing Agencies to the Owner upon project completion. H. PRODUCT LISTING OR LABELING: All electrical equipment shall be listed and labeled by Underwriters' Laboratories, Inc. I. MATERIAL AND EQUIPMENT: All materials and equipment shall be new unless noted otherwise. Protect all materials and equipment from damage or corrosion. J. CUTTING AND PATCHING: Provide all required cutting and patching for the electrical work. K. REMOVAL AND REPLACEMENT OF EXISTING ACCESSIBLE CEILING PANELS, LIGHTING FIXTURES AND SPEAKERS: Remove and reinstall all necessary ceiling panels, lighting fixtures, speakers and other existing equipment in existing accessible ceilings as required to install the electrical work. L ANCHORAGE AND BRACING: Provide complete seismic anchorage and bracing for the lateral and vertical support of conduit and electrical equipment as required by the Uniform Building Code. M. FlRESTOPPING: Provide firestopping for all penetration in rated walls, ceilings and floors. N. PAINTING: Paint all exposed raceways, except SMR, in finished areas to match adjacent surfaces. 0. INSTRUCTION: Contractor shall instruct the Owner in the use and operation of all systems installed under the scope of this contract. BASIC MATERIALS AND METHODS A. RACEWAYS AND FITTINGS 1. Raceways: a. Rigid Metallic Conduit: Zinc - coated steel with full threaded connections. b. Electrical Metallic Tubing (EMT): Zinc - coated steel. c. Rigid Nonmetallic Conduit: Rigid PVC, Schedule 40, UL listed for direct burial or concrete encasement. d. Flexible Metallic Conduit: Galvanized steel, securely interlocked. 2. Fittings: a. Rigid Metallic Conduit: 1) Couplings: Threaded metallic type of the some material as the conduit. 2) Locknuts: Steel up to 2 inches, malleable iron for 2 -1/2 inches and larger. 3) Bushings: Bakelite or plastic up to 2 inches, malleable iron with insulating collar for 2 -1/2 inches and larger. 4) Unions: Zinc plated malleable iron, 3 piece conduit coupling. a. Electrical Metallic Tubing (EMT): 1 -1/2" and smaller shall be mintight type steel employing a split corrugated ring and tightening nut. Fittings 2" and larger shall be steel and may be setscrew type containing dual setscrews on each side of coupling. b. Rigid Nonmetallic Conduit: Slip -on, nonthreaded type of some material as conduit. c. Flexible Metallic Conduit: Steel, one- or two -screw clamp type. 3. Conduit Straps: Heavy duty, two -hole pressed steel. B. 600 -VOLT WIRE AND CABLE 1. Feeders: Type THHN/THWN 600 -volt insulation, copper conductor, stranded. 2. Branch Circuits: Type THHN/THWN, 600 -volt insulation, copper conductor, stranded. Minimum size shall be No. 12 AWG for phase and ground conductors and No. 10 AWG for neutral conductors. C. OUTLET, JUNCTION AND PULL BOXES 1. Outlet and Device Boxes: a. Interior Surface- Mounted ih Unfinished Areas: One -piece pressed steel, electro- galvanized, size and depth required by Code, except 4 -inch square or 4 -inch octagonal minimum. b. Interior Flush - Mounted: Some as above except provide plaster ring extension to finished surface. c. Interior Surface - Mounted, Finished Areas: Wiremold No. 5700 Series sized to fit standard wiring device and for fire alarm devices provide boxes with a factory applied red finish (special order product). Verify device box requirements with the fire alarm supplier. 2. Junction and Pull Boxes: a. Interior Areas: Steel, screw cover, code gauge and size. Large junction and pull boxes shall be fabricated sheet steel with baked enamel finish and return flange with screw retained cover. b. Exterior. Cast, non- ferro4s metal with cast, gasketted covers; or sheet steel, hot -dip galvanized after fabrication, no KO's, with gasketted screw cover. D. WIRING DEVICES 1. Approved Manufacturers: F3ryont, Cooper Wiring Devices (Arrow hart), Hubbell, P & S or Leviton. All part numbers refer to Hubbell 2. Color of Switch Handles aNd Receptacle Faces: Ivory. 3. Receptacles: a. Duplex Receptacles: Specification- grade, except hospital grade in all patient care areas, 15 ampere, 125 volt grounded type, 5262 series. b. Dedicated Duplex Receptacles: Specification- grade, except hospital grade in all patient care areas, 20- ampere, 125 -volt grounded, 5362 series. c. Ground Fault Interruption Receptacle: Specification - grade, 20 ampere, 120 volts, Class A, 5- milliampere sensitivity, GF521 2 series. 4. Switches: a. Single -Pole Switches: Specification- grade, 20 ampere, 1221 series. b. Three -Way Switches: Specification- grade, 20 ampere, 1223 series. E. DEVICE PLATES: Satin fini4h stainless steel. Pass and Seymour /Sierra 302 "S" line or equal. F. VAULTS: Precast 30" long x 30" wide x 24" deep with an H -20 traffic -rated lid (full 18T open) and locking latch. Utility Vault Company 3030LA series with 3030 -B base and 3030 -P cover. Set on 36" deep grovel base. G. EXECUTION 1. General: a. Coordination: The Contractor shall review all drawings, details and elevations prior to rough -in. Where equipment is furnished by others, the Contractor shall ascertain the proper voltage, load and connection requirements prior to rough -in, b. Materials: All materials of a specific type shall be provided by the same manufacturer throughout the project. 2. Raceways: a. Raceway Types: Install roc;eway types and sizes as listed below: 1) Electrical Metallic Tubing (EMT): All areas other than above. May be used for feeders with integral green ground conductor. 2) Rigid Nonmetallic Conduit: Exterior underground installations; direct buried for lighting raceways. 90 degree elbows to be galvanized rigid steel. 3) Flexible Metallic Conduit: (Recessed fixture connections, interior concealed equipment connections, expansion joints and sound corltrol. Not to be used exposed installations within the building. a. Installation: 1) Concealment: All raceways; shall be concealed in finished areas. Where existing wall surfaces are inaccessible, surface metal raceways for these exceptions may be provided when approved. 2) Routing: All raceways shall be installed parallel or at right angles to the building construction unless prohibited by a physical obstruction. 3) Raceway Supports: Raceways shall be supported with heavy -duty, one -hole, pressed steel straps on interior surfaces. Support pendant- mounted raceways on 3/8 -inch rod with pear- shaped hanger or tropeze -type hanger with 3/8- -inch rod (minimum) and 1 -5/8 -inch square preformed channel and pipe clamps. Parallel, surface - mounted raceways shall be supported from 1 -5/8 -inch square preformed channel and pipe clamps. All fittings and supports shall be hot -dip galvanized in exterior areas. 4) Independent Support: Conduits shall not be supported from the ceiling suspension system, ducts, pipes or other systems foreign to the electrical installation. The entire electrical installation shall be kept independent from any other trade. 5) Puliboxes with Covers: Shall be provided as shown on the drawings or as required by Code. Al pullboxes shall be located so as to be accessible. 6) Flexible Conduit: Shall be used only for lighting fixture pigtails in accessible ceilings, flush - mounted speaker pigtails in accessible ceilings, sound control, motor connections and at building expansion joints as specified. Any other proposed use of flexible conduit must be approved prior to installation. 7) Penetrations: Raceways which pass through building roof, exterior walls of building above or below grade and floor slabs on grade, shall be sealed on the interior side of the building using non - hardening sealing compound after all conductors have been installed in the raceway. Sealing material shall be specifically designed for electrical wiring systems. 8) Conduit Passing Through Building Roof: Provide a 4 lb. lead plumbing vent flashing with a counterflashing attached above using a galvanized steel clamp. 8) Conduit Penetrating Membirones: All conduits penetrating walls or slabs with membranes shall be installed with approved membrane clamping devices in order to provide necessary seal. 10) Empty Raceways: Provide a nylon pull string in all empty raceways. 3. Wire and Cable: a. Branch Circuits: Branch circuits shall be No. 12 AWG minimum, color -coded as listed below. Homeruns greater than 75 feet to first outlet shall be No. 10 minimum. b. Feeders: Feeders shall be sized as shown on the drawings and color -coded in accordance with list below. Make no splices unless shown on the plans. c. Color Coding Requirements: 1) 120/208 Volt, 3- Phase, 4 -Wire Systems: Phase A: Black Phase B: Red Phase C: Blue Neutral: White Ground: Green Travelers: Yellow (for 3- and 4 -way switching) Controls: Black with wire numbers on each conductor 2) 277/480 Volt, 3- Phase, 3 and 4 -Wire Systems: Phase A. Brown Phase B: Orange Phase C: Yellow Neutral: Gray Ground: Green Travelers: Lavender d. Splices and Terminations: Lighting and receptacle branch circuit conductors up to No. 10 AWG shall be spliced with Wing Nut type connectors. e. Home Runs: Branch circuit conductors shall be home run to panelboards or motor control centers in groupings as shown on the drawings. Combining branch circuit home run conductors in single conduits other than that shown, will not be permitted. 4. Boxes and Fittings: a. General: Boxes shall be supported securely and independently. Mount boxes on building surfaces or support with trapeze hanger as described in Raceway Installation. Junction boxes shall not be used unless the number of bends, pulling length, or circuit requirements necessitates their installation. Junction or pullbox openings must be accessible. b. Sound Control: Where boxes are mounted in a common wall, they shall wherever possible, be offset horizontally so that they are not mounted back -to -back. Connect offset boxes with flexible conduit not to exceed 18 inches in length. 5. Wiring Devices: a. General: Install devices level, plumb and square with building lines. b. Switch Locations: Locate switches 6 inches from door casing. c. Mounting Heights: Height of devices to the center line of the box sholl be as follows unless otherwise noted. Switch: +48" Receptacle: +18" Above Counter Receptacles: Bottom of box to be 1" above backsplash or counter. 6. Grounding: a. General: Provide through the entire electrical system. A separate green equipment grounding conductor shall be provided in all lighting and power raceways. b. Bonding: Insulated grounding bushings shall be installed to bond all feeder conduits to the switchboard ground bus or panel ground bus at both ends of feeder raceways. Insulated grounding bushings shall be installed to bond all feeder conduits to the ground bus or panel enclosures at both ends of the runs. c. Receptacle Grounding: Connect the ground terminal of all receptacles by utilizing a separate grounding conductor between the receptacle grounding screw and the ground conductor provided in the branch circuit. Integral mounting straps within the receptacle connected to the device mounting straps are not approved as a grounding method. d. Flexible Conduit Grounding: Provide a separate grounding conductor in all flexible conduit runs including watertight flexible conduit with integral grounding straps. Install ground conductor inside conduit with ungrounded conductors. 8. Owner- Furnished Equipment: Provide complete electrical service and connection to all Owner - furnished equipment. 9. Identification: In general, label all junction boxes, terminal cabinets, etc., with the circuit number or low- voltage system contained within. The fire alarm junction boxes shall be painted red. DISTRIBUTION EQUIPMENT A. DISCONNECT SWITCHES 1. Approved Manufactures: General Electric, Siemens or Square D. 2. Single -Phase Motor. Motors 1/3 HP or less provide with toggle -type, 20 -amp, 120 -volt rating, specification -grade disconnect switches. 3. Three -Phase Motor: Motors 1/2 HP and larger provide with horsepower- rated, heavy -duty, 30 ampere minimum, 3 -pole disconnect switches. 4. Equipment Disconnects: Shall be fused or nonfused as required by the equipment manufacturer, rated at 125% of full load nameplate amperage or rated horsepower, heavy -duty type. B. FUSES 1. Approved Manufactures: Bussman, Ferrez Shawmut or Uttlefuse. 2. Provide 200,0 -00 AIC, current limiting, UL time delay fuses as follows: a. For feeders 601 -6000 amps: Class 4 KRP -C Time Delay. b. For feeders 600 amps and less: Class RK -1, LPN -RK for 250 -volt, dual element; Class RK -1, LPS -RK for 600 -volt, dual element; 12. ALL METAL HALIDE LAMPS /BALLASTS SHALL BE PULSE START. 13. PROVIDE GLARE SHIELDS FOR ALL POLE MOUNTED LUMINAIRE. 14. THE CONTRACTOR SHALL REVIEW THE ARCHITECTURAL INTERIOR ELEVATIONS AND THE CASEWORK MANUFACTURER SHOP DRAWINGS TO DETERMINE THE LENGTH OF UNDER COUNTER LIGHT LUMINAIRE. 15. REFER TO ARCHITECTURAL ELEVATIONS TO DETERMINE PENDANT LENGTH. 16. REFER TO THE SPECIFICATIONS AND DRAWINGS FOR ADDITIONAL REQUIREMENTS. 17. AIM ADJUSTABLE LUMINAIRES AS DIRECTED BY THE ENGINEER. SUBSTITUTIONS 1, NO POST BID SUBSTITUTIONS WILL BE CONSIDERED. 2. WHERE ONLY ONE MANUFACTURER IS LISTED, PRE -BID SUBSTITUTIONS WILL ONLY BE CONSIDERED IF A SAMPLE OF THE FIXTURE IS PROVIDED. c. For motor circuit 600 volts and below: Class RK -1 or Class J sized at 125% FLC of motor. C. EXECUTION 1. Existing Ponelboards: Provide new branch circuit breakers, including associated mounting hardware, to serve new loads. 2. Disconnects: a. General: Provide disconnects at all motors and other equipment items unless the equipment has a self- contained, Corte approved disconnecting method. Equipment disconnects shall be fused or non -fused as required by the Equipment manufacturer. b. Mounting: Coordinate mounting location with Equipment Installation Contractor and Architect. In general, mounting height to be 6'0" maximum above floor. Mount on equipment framing or provide independent support system consisting of 1 -5/8 -inch square preformed channels minimum. SPECIAL SYSTEMS A GENERAL 1. All special cabling, except fire alarm, shall be plenum -rated and run exposed in cable trays. 2. Provide metallic raceways for cables installed in walls, above inaccessible ceilings, exposed or where subject to physical damage. Raceway fill shall not exceed 40 %. 3. Equipment and wiring shown on the drawings and specified herein is to assist the Contractor in preparing his bid. Additional equipment and wiring may be required. Contractor shall provide all equipment and wiring as determined by the equipment manufacturer. Submittal shall include raceway and wiring layout. 4. Mounting Heights of devices to the centerline of the box shall be as follows unless noted otherwise: a. Fire Alarm Pull Station : +48" b. Fire alarm Hom /Strobe: Not less than 80" or greater than 96" to the bottom. c. Communicatione Outlet: +18" d. Wall- Mounted Communications Outlet: +48" B. FIRE ALARM SYSTEM 1. Scope: Provide and install all equipment and wiring necessary to expand the existing fire alarm system. 2. Manufacturer. 3. Equipment: a. Hom /Strobe: To match site standard. b. Pull Station: lfo match site standard. c. Remote Annunciator: Replace existing graphic to show new portables. 4. Wiring: Any underground wiring must be direct - burial rated and UL listed for fire alarm service. 5. Provide complete wiring from the existing fire alarm panel to all portable classrooms. END OF ELECTRICAL SPECIFICATION t 425.778.1530 2191176th Ave W. Suite 210 f 425.774.7803 Edmonds WA98026 info@tgbarchitects.com www.tgbarchitects.com ACOFFMAN N G I N E E R S 1601 Fifth Avenue, Suite 900 Seattle, WA 98101 -1625 ph 206.623.0717 fax 206.624.3775 coffman.com LASTING creativity l results l relationships YELM MOB TENANT IMPROVEMENTS 201 TAHOMA BLVD SE YELM, WA 98597 SPECIFICATIONS & LUMINAIRE SCHEDULE ISSUANCE CONSTRUCTION DOCUMENTS 02/08/2013 _PROJECT INFORMATION CEI PROJECT NO _ PROJECT MANAGER: DRAWN BY: SHEET NO E0.03 13107 JGJ LEN TOILET 1LH1 -4c 0 1LH1 -4c 0 1 LH1 -4ab r, _. 1 LH1 -4c 0 1 LH1 -4ob Y� i $-141 '1 L H 1 4 LIGHTING PLAN - FIRST FLOOR E2.11 SCALE: 1/4' = 1, —O• FILET 1 412 ENERAL NOTES 1. ALL DEVICES TO BE DEMOLISHED SHOWN BOLD AND DASHED. VERIFY QUANTITY ON SITE BEFORE BID. 2. ALL DEVICES SHOWN LIGHT LINE WEIGHT ARE EXISTING TO REMAIN, U.O.N. SYMBOL TYPE REMARKS 0 RF.A1 F.B E211 Maximum Allowed Lighting Wattage Location (floor phorroom #) Occupancy Description Allowed Watts per ft'— Gross Interior Area in ft Allowed x Area E211 CT Scan Room 1.00 362 362 4 82 328 RR Bt ( Exe m pt pe r 1612.2.7) 4 From Table 15 -1( over )- document all exceptions on form LTGLPA TotalAllow ad Watts 362 rroposea Llgnung vvan:age Location (fbor phn /roam #) Fature Description Number of Fixtures Watts/ Fixture Watts Proposed E2.11 REAII 4 82 328 RR Bt ( Exe m pt pe r 1612.2.7) 4 Total Proposed Watts my not exceed Total Allow etl well tar Interior Total Ropos ea Watts 328 ME t 425.778.1530 21911 76th Ave W. Suite 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com ACOFFMAN N G IN E E KS 1601 Fifth Avenue, Suite 900 Seattle, WA 98101 -1625 ph 206.623.0717 fax 206.624.3775 coffman.com LASTING real I results I relationships YELM MOB TENANT IMPROVEMENTS 201 TAHOMA BLVD SE YELM. WA 98597 LIGHTING PLAN - FIRST FLOOR ISSUANCE CONSTRUCTION DOCUMENTS 02/08/2013 PROJECT INFORMATION _ CEI PROJECT NO: 13107 PROJECT MANAGER: JGJ DRAWN BY: LEN SHEET NO E2.11 I MECHANICAL EQUIPMENT CONNECTION S EQUIP. NO. VAV1.23 DESCRIPTION EXISTING VAV LOCATION HALL 1414 RATING – – DISCONNECT SW. 30AS 1TL1 -15 VAV1.24 1TL1. -3 Q1 HALL 1414 - 30AS 1 \ PNi 1HXR 1TL1 -7 IT-1-155 <2 2 D _. 1TL7 -15 rTL1 -5# fit' •,,,, _. D1 4i;AN CONTR WARNING LIGHT. SEE KAvt23 DETAIL 3:' _ TOSHIBA DRAWINGS. =VAV 1 .2�3, F 60ILF', W01+ . b ''ROCS ixt ROL'r PNL ITI1 PNNI 1TH1 Z� MECHANICAL EQUIPMENT CONNECTION S EQUIP. NO. VAV1.23 DESCRIPTION EXISTING VAV LOCATION HALL 1414 RATING – – DISCONNECT SW. 30AS 7MOTORSTART 1 VAV1.24 EXISTING MAY HALL 1414 – –172A� 30AS 1 A. INFORMATION PRESENTED IN THIS SCHEDULE IS BASED ON EQUIPMENT SELECTED BY THE MECHANICAL ENGINEER DURING THE DESIGN PROCESS (PRE -BID). THE ACTUAL EQUIPMENT SELECTED BY MECHANICAL CONTRACTOR UNDER THIS CONTRACT MAY BE DIFFERENT. COORDINATE WITH MECHANICAL EQUIPMENT SUBMITTALS FOR ACTUAL LOADS AND PROVIDE OVERCURRENT PROTECTIVE DEVICES AND CIRCUIT SIZES AS REQUIRED BY THE EQUIPMENT MANUFACTURER PRIOR TO ORDERING MATERIALS OR ROUGH -IN. B. ALL DISCONNECTS ARE FUSED, U.O.N. CONFIRM FUSE SIZE WITH EQUIPMENT MANUFACTURER. C. LOCATE ALL DISCONNECTING MEANS PER 2011 NEC 430.102(B) AND AHJ REQUIREMENTS. D. ABBREVIATIONS: AS: AMPERE SWITCH HRS: HORSEPOWER RATED MOTOR DISCONNECT WITH OVERLOAD PROTECTION. POWER PLAN - FIRST FLOOR E3.11 SCALE: 1/4" = 1' -0' CIRCUITING GENERAL NOTES 1. REFER TO TOSHIBA SHOP DRAWINGS FOR ADDITIONAL REQUIREMENTS, ELEVATIONS, DETAILS, DIAGRAMS. CONTRACTOR SHALL PROVIDE ALL RACEWAYS AND CABLING FOR COMPLETE AND OPERATIONAL SYSTEM. 2. ALL DEVICES SHOWN LIGHT LINE WEIGHT ARE EXISTING TO REMAIN, U.O.N. FLAG NOTES ALL POWER OUTLETS IN THIS ROOM ARE EXISTING. It 425.778.1530 21911 76th Ave W. Suite 210 If 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com &COFFMAN N G I N E E R S 1601 Fifth Avenue, Suite 900 Seattle, WA 98101 -1625 ph 206.623.0717 fax 206.624.3775 coffman.com LASTING - -ahvity I results I relationships YELM MOB TENANT IMPROVEMENTS 201 TAHOMA BLVD SE YELM, WA 98597 POWER PLAN - FIRST FLOOR ISSUANCE CONSTRUCTION DOCUMENTS 02/08/2013 PROJECT -INFORMATION CEI PROJECT NO 13107 _PROJECT MANAGER — JGJ DRAWN BY LEN SHEET NO E3.11 REQUIRED FOR FULL NOTE. SION OF PATIENT COUCH -- - SHELF /COUNTER PROVIDED BY ATTACHMENTS. N CUSTOMER /CONTRACTOR. ' 15 2 ISO = -- / r � 5 .,. _ 01 kO')'.' NOTE: MINIMUM SERVICE CLEARANCE REQUIRED ON BOTH SIDES OF PATIENT GANTRY' ENTRY NOTE: THE EQUIPMENT SHOWN IN THIS LAYOUT MUST BE VERIFIED WITH THE FINAL PURCHASE ORDER. NOT IN CONTRACT EQUIPMENT LAYOUT 0 1' 2' 4' 8' IV POWER SOLUTION RSAP T BAT UPS 0 IN THIS LAYOUT. NOTE: A. THE POWER SOLUTION SHOWN IS FOR PLA PURPOSES ONLY. THE FINAL ORDER WILL SHOW THE POWER SOLUTION CONFIGURA RE ED TO MEET SITE SPECIFIC CONDITIONS. SEE ELECTRICAL NOTE "X' ON SHEET 1 FOR MO INFORMATION. B. THE GB000 UNINTERRUPTIBLE POW UPPLY (UPS) BATTERY CABINET (BAT) SHOWN HERE ARE TO BE REMOTELY LOCATED. C. SEE RECOMMENDED DELIVERY UIREMENTS DUNLL 5, SH GN2. D. THE REMOTE STATUS ALARM NEL (RSAP) SHOWN HERE, WI E WALL MOUNTED IN THE CONTROL ROOM. E. SEE EQUIPMENT SPECI TI ON SHEET A2. F. THE "UPS" AND "BA CABINETS CAN BE SEPARATED. CABLES BEfW\'UPS'AND "BAT" CAN BE RUN UP TO, NOT TO EXCEED, 70' -0" IN LENGT H. G. THIS EQUIPME IF PURCHASED, WILL BE PROVIDED BY TOStiIBA AY CUSTOMER / TRACTOR. H. 16" AIR F CLEARANCE ABOVE "UPS" IS REQUIRED. I. "RSAP" ONITOR MUST BE LOCATED WITHIN 1,000 FEET OF THE °UINST ED BY CUSTOMERS ELECTRICIAN. CUSTOMER'S ELECTRICIAN TED P 16 AWG CABLE (SIGNAL), AND 18 AWG WIRE (POWER) PROM ". EQUIPMENT LEGEND ITEM ELEC, ITEM DESCRIPTION BTUIHR WEIGHT REF. LEN SYM. SUPPLIED AND INSTALLED BY TOSHIBA O GANT AQUILION GANTRY * 3,859.00 A2 e O PCH AQUILON PATIENT COUCH (EXTENDED) * 1,070.00 A2 e OCPU CENTRAL PROCESSING UNIT 10,246.00 261.00 e O REC RECONSTRUCTION UNIT (BTU /HR INCLUDED WITH 'CPU") - -. -- 298.00 e O MON CONTROL MONITOR 192.00 17.60 A2 e OSPK1 SPEAKER (DESKTOP) 00.00 4.41 e OSPK2 SPEAKER (WALL MOUNT) 00.00 4.41 OSKBD KEYBOARD (SCAN) 00.00 5.95 e O DESK DESK FOR MONITORS & KEYBOARDS 00.00 221.00 A2 e 10 CHR CHAIR 00.00 55.00 e 11 INV INNERVISION WORKSTATION T.B.D 16.70 A2 e ITEM ELEC. OPTIONAL ITEM DESCRIPTION - BTUIHR WEIGHT REF. SYM. SUPPLIED & INSTALLED BY TOSHIBA 12 INJP MEDRAD INJECTOR (PEDESTAL MOUNTED) 00.00 38.00 e 13 INJC MEDRAD INJECTOR BASE UNIT 320.00 13.60 e 14 INJR MEDRAD INJECTOR DISPLAY CONTROL UNIT W /STAND 00.00 8.20 e ITEM ELEC. OPTIONAL ITEM DESCRIPTION - SUPPLIED BY TOSHIBA BTUIHR WEIGHT REF. SYM. & INSTALLED BY CUSTOMER I CONTRACTOR 15 PD POWER DISTRIBUTOR 2,730.00 1,197.00 e ITEM ELEC. OPTIONAL ITEM DESCRIPTION BTUIHR WEIGHT REF. SYM. SUPPLIED AND INSTALLED BY CUSTOMER I CONTRACTOR * AQUILION GANTRY & COUCH BTU / HOUR: EXAM ROOM SCANNING 2 PATIENTS: 20,081.00 BTU /HR EXAM ROOM SCANNING 3 PATIENTS: 21,104.00 BTU /HR EXAM ROOM SCANNING 4 PATIENTS: 22,128.00 BTU /HR EXAM ROOM SCANNING 5 PATIENTS: 23,151.00 BTU /HR EXAM ROOM SCANNING MAXIMUM: 24,175.00 BTU /HR FUTURE GROWTH OF FACILITY MUST BE CONSIDERED WHEN FORECASTING PATIENT NUMBERS FOR A/C REQUIREMENTS. REVISED: 01 -08-13 ELECTRICAL NOTES CUSTOMER 1 CONTRACTOR IS RESPONSIBLE FOR THE FOLLOWING UNLESS OTHERWISE NOTED. A. THESE SITE PLANS ARE INTENDED TO DEPICT ONLY A CONCEPT OF THE ELECTRICAL REQUIREMENTS FOR THE TOSHIBA EQUIPMENT. THE DESIGN OF ALL ELECTRICAL ELEMENTS MUST BE SPECIFIED BY A LICENSED ELECTRICAL ENGINEER IN ACCORDANCE WITH TOSHIBA SPECIFICATION AND ALL APPLICABLE CODES. B. IN ACCORDANCE WITH NEC ARTICLE 517- 72(B), THE EQUIPMENT CIRCUIT BREAKER(S) MUST BE LOCATED SO THAT THEY SHALL BE OPERABLE FROM A LOCATION READILY ACCESSIBLE FROM THE CONTROL AREA IF PHIS IS IMPOSSIBLE OR IMPRACTICAL, THE USE OF A SHUNT TRIP TYPE BREAKER WILL BE NECESSARY TO SATISFY THIS REQUIREMENT. THE EMERGENCY OFF BUTTON FOR THE SHUNT TRIP SHOULD BE LOCATED IN THE CONTROL AREA. C. THE CUSTOMER /CONTRACTOR SHALL SUPPLY AND INSTALL ALL CIRCUIT BREAKERS, CONDUITS, JUNCTION BOXES, DUCTS, ETC. SPECIFIED HEREIN. D. THE TOSHIBA SITE PLANS DO NOT SPECIFY ELECTRICAL REQUIREMENTS FOR EQUIPMENT NOT SOLD BY TOSHIBA. THESE REQUIREMENTS MUST BE OBTAINED BY THE VENDOR. E. TOSHIBA WILL SUPPLY INTERCONNECTING CABLES FOR THE TOSHIBA EQUIPMENT. TOSHIBA WILL INSTALL IF LOCAL TRADE LABOR PERMITS. F. EXCEPT FOR THEIR USE IN POWER LINE CONNECTIONS TO EQUIPMENT CABINETS, FLEXIBLE CONDUIT SHALL NOT BE USED IN THIS INSTALLATION. ONLY FACTORY CONDUIT ELBOWS SHALL BE USED. G. DUCT WORK SHALL 6E PROVIDED WITH SWEEP ELBOWS. H. ALL JUNCTION BOXES AND DUCTS THAT PENETRATE THE FLOOR SHALL BE WATERPROOF TYPE AND PROVIDED WITH GASKETED WATERPROOF COVERS. ALL FLOOR JUNCTION BOXES AND DUCT COVERS SHALL BE CAPABLE OF SUPPORTING A CONCENTRATED LOAD OF 200 LBS. I. GROMMETED OPENINGS ARE SHOWN FOR REFERENCE PURPOSES ONLY. VERIFY SIZE AND LOCATION WITH TOSHIBA REPRESENTATIVE. ALL GROMMETED OPENINGS SHALL HAVE NO SHARP EDGES. J. ALL CHASE & GROMMETED OPENINGS SHALL HAVE PLASTIC /NYLON BUSHINGS. K. ALL WALL DUCT WORK SHALL HAVE A MINIMUM OF THREE COMPARTMENTS. TRANSITIONS SUCH AS HORIZONTAL TO VERTICAL WALL DUCT OR WALL DUCT TO JUNCTION BOXES MUST BE REVIEWED ON AN INDIVIDUAL BASIS WITH THE INSTALLATION PROJECT MANAGER. LOCAL CODES. MAY REQUIRE THE USE OF CROSS -OVER TUNNELS OR OTHER SUCH DEVICES TO MAINTAIN CABLE SEPARATION. L. ALL DUCT AND CONDUITS SHALL BE ELECTRICALLY BONDED AS A GROUNDING PATH IN ACCORDANCE WITH NEC ARTICLE 517- 13(B). M. CUSTOMER /CONTRACTOR SHALL SUPPLY AND INSTALL GREENLEE NYLON MEASURING PULL STRING OR EQUIVALENT IN ALL CONDUITS AND CLOSED DUCT WORK. N. CONDUIT RUNS SHOWN ARE FOR REFERENCE ONLY. ALL CONDUIT RUNS MUST TAKE THE SHORTEST MOST DIRECT ROUTE POSSIBLE, 0. CONDUIT RUNS MAY HAVE A MAXIMUM OF (3) 90' BENDS. P. 110VAC GROUNDED OUTLETS SHALL BE PROVIDED ON WALLS NEAR THE TOSHIBA EQUIPMENT FOR USE DURING EQUIPMENT SERVICE. Q. CUSTOMER /CONTRACTOR MUST SUPPLY AND INSTALL ALL INCOMING POWER CABLES FROM CIRCUIT BREAKER(S) TO TOSHIBA EQUIPMENT CONNECTION POINT. CABLE TYPE MUST BE MTW MULTI - STRAND COPPER - NO ALUMINUM IS PERMITTED. CABLE SIZE MUST BE IN ACCORDANCE WITH TOSHIBA POWER QUALITY REQUIREMENTS. (SEE SHEET E ?). R. CUSTOMER /CONTRACTOR IS TO SUPPLY AND INSTALL ALL NECESSARY HARDWARE TO ENCLOSE INCOMING POWER CABLES IN FLEXIBLE WATER TIGHT CONDUIT FROM CIRCUIT BREAKER(S) TO TOSHIBA EQUIPMENT CABINET(S). S. ANY CHANGES IN THE LOCATION OR TYPE OF CONDUIT, DUCT WORK, JUNCTION BOXES, ETC. MUST BE SUBMITTED IN WRITING TO THE TOSHIBA INSTALLATION PROJECT MANAGER FOR APPROVAL. T. A SEPARATE CIRCUIT, FED FROM THE FACILITY RADIOLOGY PANEL OR A MAIN SERVICE PANEL IS REQUIRED. USE OF A SUB PANEL WITH LOADS SUCH AS ELEVATORS, HVAC, MOTORS, ETC. IS NOT PERMITTED. U. ALL DUCT WORK MAKING A 90' ANGLE MUST BE CHAMFERED FOR CABLE ACCESS. V. JUNCTION BOX SIZE5 MAY BE INCREASED AS NEEDED (WITH THE EXCEPTION OF THE "PD", "PCDU OR "UPS" JUNCTION BOX IF APPLICABLE). W. FIBER OPTIC CABLES REQUIRE A MINIMUM RADIUS OF 4 1/2'. DUCT WORK DESIGN MUST ACCOMMODATE THIS REQUIREMENT. ME t 425.778.1530 21911 76th Ave W. Suite 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com ,&COFFMAN N G I N E E R S 1601 Fifth Avenue, Suite 900 Seattle, WA 98101 -1625 ph 206.623.0717 fax 206.624.3775 coffman.com LASTING c,eativity I results I relationships YELM MOB TENANT IMPROVEMENTS 201 TAHOMA BLVD SE YELM, WA 98597 ENLARGED PLANS & DETAILS ISSUANCE CONSTRUCTION DOCUMENTS 02/08/2013 PROJECT INFORMATION CEI PROJECT NO: 13107 PROJECT MANAGER: JGJ DRAWN-BY: LEN SHEET NO E3.12 MAIN T EPO BS INJP TO BE LOCATED BY CUSTOMER / CONTRACTOR. ADDITIONAL "EPO" SWITCHES TO BE LOCATED IN ADJACENT ROOMS WITH TOSHIBA EQUIPh IF MAIN "EPO" IS NOT ACCESSIBLE (VERIFY WITH LOCAL CODE). ALL "EPO" SWITCHES TO PROVIDED BY CUSTOMER / CONTRACTOR. rl /. ......�.... _.... PD VR2 f J6 O VR1 TD . _ . CAN / INJP PK TOSHIBA SUPPLIED POWER CABLE BETWEEN THE "PD" AND TOSHIBA EQUIPMENT ARE TO BE USED IF THE CABLE LENGTHS PROVIDED ARE SUFFICIENT. SEE DETAIL 2, SHEET E3. IN CASES WHERE EXTENDED CABLE LENGTHS ARE REQUIRED, THE CUSTOMER /CONTRACTOR MUST PROVIDE CABLES PER LOCAL /NATIONAL CODES. /CONTRACTOR IS RESPONSIBLE FOR ALL CABLES ARE IN COMPLIANCE WITH ALL IONAL CODES. NOTE: J -BOX SIZES MAY BE INCREASED AS NEEDED WITH EXCEPTION TO THE "PDU" J -BOX. NOTE., GROMMETED OPENINGS ARE SHOWN FOR REFERENCE ONLY. VERIFY SIZE AND LOCATION WITH TOSHIBA REPRESENTATIVE. NM FIBER OPTICAL CABLES FROM RECONSTRUCTION UNITS REQUIRE A MINIMUM BENDING RADIUS OF 4 1/2 ". DUCT WORK DESIGN MUST ACCOMMODATE THIS REQUIREMENT. CPU r: r I k,•` F_ REC PK INV INJC INJR r r (PROVIDED FOR REFERENCE PURPOSES ONLY) 0 1' 2' 4' 8' 16' CABLE KEY - - °•• M-•- N/UNDER FLOOR ,.. ,....,. .............„.. VER CEILING °•°°•� "• ^ °- -_- ONTRACTOR DETERMINED EPO MAIN BS PD f NOTE: FOR ABOVE CONNECTIONS, SEE DETAIL 2, SHEET E3. ALL CABLES AND CONDUITS REQUIRED ARE TO BE PROVIDED RV rimTnurR rnN ArTnR N a �I EXISTING PANEL IHXR WITH NEW BREAKER "CB" PER ONF LINE AND PANEL SCHEDULE JB PD T- VR2 VR1 "REF. PT.' A. _ISO GAIT INJP N. .INJC PK INJR TCILC x"14 , JKIdT $lf,l,^ CT AH 10OM 4.11t ' WD WL ELECTRICAL LAYOUT 0 1' 2' 4' 8' 16• CEILING CONDUIT SCHEDULE ITEM CONTRACTOR CONDUIT REFERENCE CABLE REFERENCE SUPPLIED AND INSTALLED BY CUSTOMER I CONTRACTOR RUN NO. CONDUIT (POINT TO POINT) CONDUIT (ROUTING) CONDUIT (DIAMETER) CONDUIT (MAX LENGTH) CABLE (POINT TO POINT) CABLE LENGTH (USABLE) CABLES (SUPPLIED BY) LOCATION PER CODE REQUIREMENTS BY ELECTRICAL CONTRACTOR. E3 1 O O PK WL JB O JB OVER CEILING CONTRACTOR DETERMINED 1/2" PER MANUFACTURER 40' -0" PER MANUFACTURER j PK WrL 4 t CPU O GAN I SEE RUN "G" DETAIL (1/E4) PER MANUFACTURER TOSHIBA CONTRACTOR 4" STD. J -BOX FOR "X�- RAY ON" OR WARNING UGHT MOUNTED ABOVE PATIENT ENTRY DOOR. 3 E3 BS BUILDING STEEL. 2 E3 GAN ------ 5 E3 SPK (EXISTING) SHARED GROMMETED OPENING IN WALL DUCT "WD ". NOTE: A. CONDUITS SUPPLIEDIINSTALLED BY CUSTOMERICONTRACTOR. B. ALL CONDUIT RUNS MUST TAKE THE SHORTEST MOST DIRECT ROUTE POSSIBLE. C. " IF RUN IS GREATER THAN LENGTH SHOWN, CUSTOMERICONTRACTOR TO PROVIDE CABLES. REFER TO DETAIL7, SHEET E3. D. CONDUIT IS NOT TO BE RUN IN SUCH A MANNER THAT WILL EXCEED CONDUIT MAXIMUM LENGTH AS SHOWN IN THE SCHEDULES. INV ELECTRICAL LEGEND ITEM ITEM DESCRIPTION REF. SUPPLIED AND INSTALLED BY CUSTOMER I CONTRACTOR MAIN MAIN SERVICE ENTRANCE PANEL 2 E3 THREE PHASE CIRCUIT BREAKER PER TOSHIBA POWER SPECIFICATIONS (SEE DETAIL) CIRCUIT BREAKER CB LOCATION PER CODE REQUIREMENTS BY ELECTRICAL CONTRACTOR. E3 PD FLEX CONDUIT FROM 'WD" TO CABINET. 2 E3 4" STD. J -BOX FOR REMOTE OFF SWITCH. LOCATED BY CUSTOMER /CONTRACTOR. OEPO DPDT, NORMALLY OPEN MUSHROOM HEAD PUSH BUTTON. E3 e WL 4" STD. J -BOX FOR "X�- RAY ON" OR WARNING UGHT MOUNTED ABOVE PATIENT ENTRY DOOR. 3 E3 BS BUILDING STEEL. 2 E3 GAN GROMMETED OPENING IN "TD" COVER OPEN TO GANTRY CABLE TRAY. 5 E3 SPK (EXISTING) SHARED GROMMETED OPENING IN WALL DUCT "WD ". INV REC SHARED GROMMETED OPENING IN WALL DUCT "WD" 5 E3 CPU 4" STD. J -BOX FOR SCAN ROOM SPEAKER, FLUSH MOUNTED 58" A.F.F. TO BOTTOM OF BOX (IN PK PROCEDURE ROOM). e INJP CONNECTS TO "GANT ". e INJC (EXISTING) SHARED GROMMETED OPENING IN WALL DUCT "WD ? ". INJR (EXISTING) 12" W X 120 H X 4" D J -BOX, FLUSH MOUNTED 29" A.F.F. TO BOTTOM OF BOX. 0 JB OPEN TO "VR1 ". Il0V ELECTRICAL OUTLETS FOR SYSTEM EQUIPMENT AND /OR SERVICE EQUIPMENT. OUTLETS TO BE LOCATED IN EACH ROOM WHERE SYSTEM EQUIPMENT IS LOCATED. e RJ45 CONNECTOR, CATS CABLE TO BE USED FOR DATA CONNECTION FOR NETWORKING. e DEDICATED PHONE LINE SUPPLIED /INSTALLED BY CUSTOMER /CONTRACTOR. e ELECTRICAL DUCT LEGEND ITEM ITEM DESCRIPTION REF. SUPPLIED AND INSTALLED BY CUSTOMER I CONTRACTOR 10" W X 3 1/2" D FLUSH /SURFACE MOUNTED WALL DUCT, W /(3) EQUALLY PARTITIONED COMPARTMENTS W,D THROUGHOUT & REMOVABLE ACCESS COVERS. MOUNTED 12" A.F.F. TO BOTTOM OF DUCT. OVR1 10" W X 3 1/2" D SURFACE MOUNTED RISER DUCT, W /(3) EQUALLY PARTITIONED COMPARTMENTS THROUGHOUT & REMOVABLE ACCESS COVERS. FROM "JB" TO "WD ". 10" W X 3 1/2" D SURFACE MOUNTED RISER DUCT, W /(3) EQUALLY PARTITIONED COMPARTMENTS OVR2 THROUGHOUT & REMOVABLE ACCESS COVERS. FROM "TD" TO "WD ". 12" W X 2 1/2" D FLUSH MOUNTED TRENCH DUCT, W /(3) EQUALLY PARTITIONED COMPARTMENTS TD THROUGHOUT & REMOVABLE ACCESS COVERS (THICKNESS SHOULD BE ABLE TO SUPPORT MIN. OF 200 LBS.) ARE REQUIRED. sm t 425.778.1530 21911 76th Ave W. Suite 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchilects.com jCOFFMAN N G I N E E R S 1601 Fifth Avenue, Suite 900 Seattle, WA 98101 -1625 ph 206.623.0717 fax 206.624.3775 coffman.com LASTING creativity results relationships YELM MOB TENANT IMPROVEMENTS 201 TAHOMA BLVD SE YELM, WA 98597 ENLARGED PLANS & DETAILS ISSUANCE CONSTRUCTION DOCUMENTS 0210 812 01 3 PROJECTIN FORMATION _ CEI PROJECT NO 13107_ PROJECT MANAGER:_ JGJ DRAWN BY LEN SHEET NO E3.13 POWER QUALITY REQUIREMENTS AQUILION 5UPVLT UUMNUUM11UN3 PHASE, 3 WIRE POWER, AND GROUND, DELTA OR WYE (SEE NOTr_A7_ NOMINAL UNE VOLTAGE 480 VAC, 60 HZ (SEE NOTE B) LINE VOLTAGE VARIATION 10% STEADY -STATE INCLUDING SAGS AND SURGES LINE VOLTAGE BALANCE ?% MAXIMUM OF NOMINAL VOLTAGE BETWEEN PHASES. FREQUENCY VARIATION 1 HZ MARMUNIL; UIbIUKIIUN5% ------- STEADY—STATE, 5% FOR SHORT PERIODS INUTE OR LESS) URUURU_CORUUMUff79PEDARCE).1 OHMS 9 60 HZ, TO N - OTE D) STANDARD TRANSFORMER CAPACITY 50 KVA MAXIMUM SYSTEM DEMAND 00 KVA (IMAGING) CONTROL AREA W/ A NORMALLY OP CONDUCTOR SIZES (SEE NOTE E) FOR 1.5% IMPEDANCE OF BRANCH CONDUCTORS (2_170 CONTACT (IF REQUIRED). ONDUCTOR SIZE GTH REAKER FRAME SIZE 2 AWG 218 FT. 00 A 1 AWG 303 FT. 00 A /0 AWG 377 FT. 00 A /0 AWG 444 FT. 00 A B = 26" 'IRCUrr BREAKER SIZE: (SEE NOTE I UU A DUCT: MOMENTARY MAXIMUM CURRENT 50 A MAXIMUM VOLTAGE DROP Z4.0 V B % REGULATION 5.0% STANDARD POWER QUALITY NOTES A A GROUNDED NEUTRAL POWER SOURCE IS REQUIRED TO ASSURE RELIABLE EQUIPMENT OPERATION. THE NEUTRAL CONDUCTOR MAY NOT BE USED FOR A PARTICULAR SYSTEM. B. IN CASES WHERE MULTIPLE VOLTAGES ARE PERMITTED, THE PREFERRED SYSTEM VOLTAGE IS SPECIFIED. C. DUE TO THE HIGH INSTANTANEOUS POWER OF MEDICAL IMAGING SYSTEMS, USE THE HIGHEST AVAILABLE VOLTAGE SOURCE. ENSURE THAT LOWER VOLTAGE SOURCES ARE DERIVED DIRECTLY FROM THE SERVICE ENTRANCE OF THE FACILITY. D. GROUND CONDUCTORS ARE REQUIRED TO BE THE SAME SIZE AS THE PHASE CONDUCTORS UNLESS A LARGER SIZE IS REQUIRED BY CODE. E. ALL FEEDER AND BRANCH CIRCUIT CONDUCTORS MUST BE COPPER — ALUMINUM IS NOT PERMITTED. F. IF THE EQUIPMENT CIRCUIT BREAKER IS NOT LOCATED IN THE CONTROL AREA, A SHUNT TRIP BREAKER MUST BE USED IN ORDER TO COMPLY WITH N.E.C. 517- 72(B). A PUSH — BUTTON TO OPERATE THE SHUNT TRIP MUST BE LOCATED IN THE CONTROL AREA. G. A SEPARATE CIRCUIT, FED FROM THE FACILITY RADIOLOGY PANEL OR A MAIN SERVICE PANEL IS REQUIRED. USE OF A SUB PANEL WITH LOADS SUCH AS ELEVATORS, WAG, MOTORS, ETC., IS NOT PERMITTED. H. DEVICES SUCH AS UNINTERRUPTIBLE POWER SUPPLIES, POWER CONDITIONERS, VOLTAGE REGULATORS, AND FILTERS MAY BE INCOMPATIBLE WITH THIS IMAGING EQUIPMENT. CONSULT YOUR TOSHIBA SERVICE REPRESENTATIVE PRIOR TO PURCHASING OR INSTALLING THESE DEVICES. I. THE MAINS POWER GROUND CONDUCTOR IS TO BE RUN WITH THE POWER PHASE CONDUCTORS. THE GROUNDS TO BUILDING STEEL OR EARTH GROUND ARE NOT TO BE RUN WITH THE PHASE CONDUCTORS. �` 175 AMP "GANT" 480V, 3 POLE I I 40 AMP G I ' G I 50 AMP I "CPU" 480V, 100 AMP • REFER TO DETAIL 1, SHEET E3 FOR DUCT: CONDUCTOR SIZE USING COMBINED LENGTHS INSIDE CT ROOM (IF OF RUNS "X" & "Y ". POSSIBLE) 250 -30(A) PER ADDITIONAL "EPO" SWITCHES TO BE STEEL, WATER PIPE, LOCATED BY CUSTOMER /CONTRACTOR IF NEC SECTION 250 NEEDED. EMERGENCY "PD ". GROUND CONDUCTORS MUST BE S&E POWER OFF SHUNT TRIP PUSH BUTTON IN "EPO" CONTROL AREA W/ A NORMALLY OP PUSH BUTTON CONTACT (IF REQUIRED). (DPDT) A = 18" WIRES PER CODE TO SHUNT TRIP PUSH BUTTON. X °• SHUNT TRIP CIRCUIT BREAKER SUPPLIED AND • BY TOSHIBA `l� (SEE NOTE 1) �` 175 AMP "GANT" 480V, 3 POLE I I 40 AMP G I ' G I 50 AMP I "CPU" 480V, 100 AMP 3A SUPPLIED POWER CABLES BETWEEN THE "PD" AND TOSHIBA EQUIPMENT ARE TO BE IF THE CAEILE LENGTHS PROVIDED ARE SUFFICIENT. IN CASES WHERE EXTENDED CABLE IS ARE REQUIRED, THE CUSTOMER /CONTRACTOR MUST PROVIDE CABLES PER /NATIONAL CODES. CUSTOMER SUPPLIED I TOSHIBA SUPPLIED "X —RAY ON" WARNING LIGH MOUNTED ABOVE SCAN ROOM DOOR. NEUTRAL 120V LOCATED NEAR 'X —RAY ON" OR WARNING LIGHT ON PER TOSHIBA X —RAY SIGNAL. NOTE: A. "X —RAY ON" OR WARNING LIGHT TO BE PROVI ED BY CUSTOMER /CONTRACTOR. B. USE INCANDESCENT FIXTURES ONLY. WALL FLEX CONDUIT FROM WALL DUCT /J —BOX TO 10" W X 10" H X 4" D J —BOX, FLUSH MOUNTED IN FINISHED WALL. OPEN TO WALL DUCT. NOTE: SUGGESTED MOUNTING OF J —BOX FOR "PD" OR AS PER LOCAL CODE. Z "CB" I "PD" WIRING DETAIL O WARNING LIGHT DETAIL 4 TYPICAL "PD" J -BOX MOUNTING SCALE: NOT TO SCALE 01 -08 -13 SCALE: NOT TO SCALE 01 -08 -13 SCALE: 1/2" = 1' -0" 01 -08 -13 P1QIE NOTE' GROMMETED OPENING OR CUSTOMER'S CONTRACTOR TO VERIFY LOCATION OF SPLIT ACCESS COVER ON J— BOXES) FOR CABLE PULL TO WALL DUCT. FACE OF WALL DUCT. CUSTOMER'S CONTRACTOR TO VERIFY LOCATION OF GROMMETED OPENINGS IN WALL DUCT WITH TOSHIBA REP. 45' SECTION FOR SURFACE MOUNTED WALL DUCT ALL WALL DUCT W /(3) EQUALLY DMDED CORNERS. PARTITIONS THROUGHOUT W/ PARTITION CUT —OUTS AT �)I DAMAGE MAY OCCUR 200% ABOVE NOMINAL VOLTAGE SYSTEM DISRUPTION MAY OCCUR 100% ABOVE (DISRUPTIVE IMPULSES) SYSTEM DAMAGE MAY OCCUR NOMINAL VOLTAGE (HIGH VOLTAGE, SWELLS, & SURGES) V +10% ABOVE NOMINAL NOMINAL VOLTAGE — — — — — — — — — — — — — — — — —10% BELOW NOMINAL * , SYSTEM DISRUPTION MAY OCCUR N4 ACCEPTABLE VOLTAGE RANGE (LOW VOLTAGE, SAGS, & OUTAGE) °^ 10 1JS 100 NS 1 ms 10 ms 100 ms 1 Sec 1 Min 1 Hr 3H MOUNTED J —BOX WALL DUCT) 10" TRENCH DUCT: A GROUND SOURCE GROUND ELECTRODE PER NEC 250 -30(A) PER BUILDING STEEL, WATER PIPE, OR GROUNDING ELECTRODE AS CLOSE AS NEC SECTION 250 PHYSICALLY POSSIBLE TO THE "PD ". GROUND CONDUCTORS MUST BE S&E SIZE AS PHASE CONDUCTORS. 18" 3A SUPPLIED POWER CABLES BETWEEN THE "PD" AND TOSHIBA EQUIPMENT ARE TO BE IF THE CAEILE LENGTHS PROVIDED ARE SUFFICIENT. IN CASES WHERE EXTENDED CABLE IS ARE REQUIRED, THE CUSTOMER /CONTRACTOR MUST PROVIDE CABLES PER /NATIONAL CODES. CUSTOMER SUPPLIED I TOSHIBA SUPPLIED "X —RAY ON" WARNING LIGH MOUNTED ABOVE SCAN ROOM DOOR. NEUTRAL 120V LOCATED NEAR 'X —RAY ON" OR WARNING LIGHT ON PER TOSHIBA X —RAY SIGNAL. NOTE: A. "X —RAY ON" OR WARNING LIGHT TO BE PROVI ED BY CUSTOMER /CONTRACTOR. B. USE INCANDESCENT FIXTURES ONLY. WALL FLEX CONDUIT FROM WALL DUCT /J —BOX TO 10" W X 10" H X 4" D J —BOX, FLUSH MOUNTED IN FINISHED WALL. OPEN TO WALL DUCT. NOTE: SUGGESTED MOUNTING OF J —BOX FOR "PD" OR AS PER LOCAL CODE. Z "CB" I "PD" WIRING DETAIL O WARNING LIGHT DETAIL 4 TYPICAL "PD" J -BOX MOUNTING SCALE: NOT TO SCALE 01 -08 -13 SCALE: NOT TO SCALE 01 -08 -13 SCALE: 1/2" = 1' -0" 01 -08 -13 P1QIE NOTE' GROMMETED OPENING OR CUSTOMER'S CONTRACTOR TO VERIFY LOCATION OF SPLIT ACCESS COVER ON J— BOXES) FOR CABLE PULL TO WALL DUCT. FACE OF WALL DUCT. CUSTOMER'S CONTRACTOR TO VERIFY LOCATION OF GROMMETED OPENINGS IN WALL DUCT WITH TOSHIBA REP. 45' SECTION FOR SURFACE MOUNTED WALL DUCT ALL WALL DUCT W /(3) EQUALLY DMDED CORNERS. PARTITIONS THROUGHOUT W/ PARTITION CUT —OUTS AT �)I DAMAGE MAY OCCUR 200% ABOVE NOMINAL VOLTAGE SYSTEM DISRUPTION MAY OCCUR 100% ABOVE (DISRUPTIVE IMPULSES) SYSTEM DAMAGE MAY OCCUR NOMINAL VOLTAGE (HIGH VOLTAGE, SWELLS, & SURGES) V +10% ABOVE NOMINAL NOMINAL VOLTAGE — — — — — — — — — — — — — — — — —10% BELOW NOMINAL * , SYSTEM DISRUPTION MAY OCCUR N4 ACCEPTABLE VOLTAGE RANGE (LOW VOLTAGE, SAGS, & OUTAGE) °^ 10 1JS 100 NS 1 ms 10 ms 100 ms 1 Sec 1 Min 1 Hr 3H MOUNTED J —BOX WALL DUCT) 10" TRENCH DUCT: A = 10" B= 12" 16" TRENCH DUCT: A = 16" B= 18" 18" TRENCH DUCT: A = 18" 6 = 20" 24" TRENCH DUCT: A = 24' B = 26" 30" TRENCH DUCT: A = 30" B =32" TYPICAL DUCT DETAIL WITH WALL DUCT POWER REQUIREMENTS WITH PCDU O TRENCH DUCT I J -BOX I VERTICAL RISER SCALE: NOT TO SCALE 01 -08 -13 SCALE: NOT 70 SCALE 01 -08 -13 t 425,778.1530 21911 76th Ave W. Suite 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com ACOFFMAN N G I N E E R S 1601 Fifth Avenue, Suite 900 Seattle, WA 98101 -1625 ph 206.623.0717 fax 206.624.3775 coffman.com LASTING creativity I resulm I relationships YELM MOB TENANT IMPROVEMENTS 201 TAHOMA BLVD SE YELM, WA 98597 ENLARGED PLANS & DETAILS ISSUANCE CONSTRUCTION DOCUMENTS 02/08/2013 PROJECT -INFORMATION CEI PROJECT NO 13107 PROJECT MANAGER: _ _JGJ — -- DRAWN BY LEN SHEET NO E31.14 1. f SYSTEMS PLAN - FIRST FLOOR E3.11 SCALE: 1/4* = 1' -0' GENERAL NOTES 1. ALL DEVICES SHOWN LIGHT LINE WEIGHT ARE EXISTING TO REMAIN, U.O.N. FLAG NOTES D NEW VOICE /DATA OUTLET ROUGH —IN AND RACEWAY PROVISION. t 425.778.1530 21911 76th Ave W. Suite 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com ACOFFMAN N G I N E E R S 1601 Fifth Avenue, Suite 900 Seattle, WA 98101 -1625 ph 206.623.0717 fax 206.624.3775 coffman.com LASTING creativity I results I relationships YELM MOB TENANT IMPROVEMENTS 201 TAHOMA BLVD SE YELM, WA 98597 SYSTEMS PLAN FIRST FLOOR ISSUANCE CONSTRUCTION DOCUMENTS 02/08/2013 PROJECT INFORMATION CEI PROJECT NO: 13107 PROJECT MANAGER: JGJ DRAWN BY: LEN SHEET NO E4.11 PNL IHXR 2® d 2 2 qz TOILET Fi:A) 7 _ PROVIDE NEW STROBE ONLY DEVICE AS AN EXTENSION OF THE IXISTING FIRE ALARM SYSTEM. TOILET __. SOILED DRF"^ j PROCEDURE ROOMo- PNI 1111 PNL =1H1� `3';P SYSTEMS PLAN - FIRST FLOOR E3.11 SCALE: 1/4* = 1' -0' GENERAL NOTES 1. ALL DEVICES SHOWN LIGHT LINE WEIGHT ARE EXISTING TO REMAIN, U.O.N. FLAG NOTES D NEW VOICE /DATA OUTLET ROUGH —IN AND RACEWAY PROVISION. t 425.778.1530 21911 76th Ave W. Suite 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com ACOFFMAN N G I N E E R S 1601 Fifth Avenue, Suite 900 Seattle, WA 98101 -1625 ph 206.623.0717 fax 206.624.3775 coffman.com LASTING creativity I results I relationships YELM MOB TENANT IMPROVEMENTS 201 TAHOMA BLVD SE YELM, WA 98597 SYSTEMS PLAN FIRST FLOOR ISSUANCE CONSTRUCTION DOCUMENTS 02/08/2013 PROJECT INFORMATION CEI PROJECT NO: 13107 PROJECT MANAGER: JGJ DRAWN BY: LEN SHEET NO E4.11 NOTE: Based on THHN insulation, conduit and Appendix C, Table C10m, or Chapter 9, Table 4 and Table 5. of the NEC, 1999 edition. * - Indicates acceptable overcurrent device rating for single feeder. This rating shall not be used for sizing parallel feeders. Load cannot exceed feeder ampacity Suitable as equipment feeder only. Not to be used for panel feeder MAIN SWITCHBOARD 'MSB', 1000A, 65KAIC, 480/277V, 30, 4W F OWNER CHECK METERING -- 2S 200 MAIN PIPE TO UTILITY SERVICE AT EXISTING PRIMARY EXCEPT SWITCHGEAR. NO GROUND ROOFTOP AC -UNIT NTH -1 300A 3P M2 NFW 300A 3P EXISTING SIGNAL WIRING FOR OWNER CHECK METERING 400A 3P TO BUILDING STEEL 40 1 1 225A 100A ) 600A 3P 1 3P- P 3P P SPACE ONE -LINE DIAGRAM SCALE: NONE FLAG NOTES: PSE PAD MOUNTED TRANSFORMER. EXISTING GROUND PER NEC. EXISTING EMON METERS. ® PROVIDE RUSSELLSTOLL #DF2504FRAB OUTLET WITH DSC20 CAP AND LANYARD. "M #" INDICATES METERING NUMBER AND LOCATION OF CTS FOR OWNER CHECK METERS. SEE FLAG NOTE #6. TYPICAL TENANT PANEL ARRANGEMENT (BY OTHERS) PANEL ADD 60A 3P PANEL PANEL PANEL PANEL r2ANEL 2HML BREAKER FOR PANEL 2LP1 2TL1 2TH1 STILE IT 1TL3 - MHHO MLO TRANSFORMER 225KVA 480V- 208/120V i 3014W, K -4 -- TO 1LP1 Y30N 1 t/2' -4/2 & tj2c EXCEPT 1.5 "R & NEUTRAL PANEL 1 TL3 SHALL BE #6 CU EXTEND EXISTING 22" /// IMAGING EQUIPMENT RACI.WAY FROM 30N 10N 30N 15N 15N lON PANEL- - CEILING 51'ACE M4 �` I n nnn PANEL PANEL PANEL PANEL PANELI PANEL WP o) S.T. 'LP1 1'L1 1TL21 1TL77 1THZ 1HXR (- t� C OOA-3P 60N 600A C) 600A 10N -. 200A -3P MLO TVSS MOB ELEVATOR " " -- (30HP) y^ h <1 IN �• MS,M M6� 2"-3#4/0 & 1 #4 /OG X -RAY WOBILE IMAGING - me M49 t 425.778.1530 21911 76th Ave W. Suite 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.t g ba rc h itec ts. co m ACOFFMAN N G I N E E R S 1601 Fifth Avenue, Suite 900 Seattle, WA 98101 -1625 ph 206.623.0717 fax 206.624.3775 coffman.com LASTING creativity 1 results I relationships NOW YELM MOB TENANT IMPROVEMENTS 201 TAHOMA BLVD SE YELM, WA 98597 ONE -LINE DIAGRAM ISSUANCE CONSTRUCTION DOCUMENTS 02/08/2013 FEEDER SCHEDULE COPPER CEI PROJECT NO: _ 1_3107 PROJECT MANAGER: JGJ DRAWN BY: LEN AMPACITY/ ID NO RACEWAY WIRE COUNT & SIZE OCP SIZE NOTES 03N 1/2' 4 - #10, 1 #10 G. 30 / 30 60 -deg rating 03 1/2' 3 - #10, 1 #10 G. 30 / 30 60 -deg rating 04N 3/4' 4 - #8, 1 #10 G. 40 / 40 60 -deg rating 04 3/4- 3 - #8, 1 #10 G. 40 / 40 50 -deg rating 05N i- 4 - #6, 1 #10 G. 55 / 50 60 -deg rating 05 3/4- 3 - #6, 1 #10 G. 55 / 50 60 -deg rating 06N 1 1/4' 4 - #4, 1 #10 G. 70 / 60 60 -deg rating 06 1" 3 - #4, 1 #10 G. 70 / 60 60 -deg rating 07N 1 1/4- 4 - #4, 1 #8 G. 70 / 70 60 -deg rating 07 1" 3 - #4, 1 #8 G. 70 / 70 60 -deg rating 08N 1 1/4' 4 - #2, 1 #8 G. 95 / 80 60 -deg rating 08 1 1/4' 3 - #2, 1 #8 G. 95 / 80 60 -deg rating 09N 1 1/4' 4 - #2, 1 #8 G. 95 / 90 60 -deg rating 09 1 1/4' 3 - #2, 1 #8 G. 95 / 90 60 -deg rating 1ON 1 1/2' 4 - #1, 1 #8 G. 110 / 100 60 -deg rating 10 1 1/2" 3 - #1, 1 #8 G. 110 / 100 60 -deg rating 11N 1 1/2- 4 - #1, 1 #6 G. 130 / 110 75 -deg rating 11 1 1/2" 3 - #1, 1 #6 G. 130 / 110 75 -deg rating 12N 1 1/2' 4 - #1, 1 #6 G. 130 / 125 75 -deg rating 12 1 1/2" 3 - #1, 1 #6 G. 130 / 125 75 -deg rating 15N 2" 4 - #1/0, 1 #6 G. 150 / 150 75 -deg rating 15 1 1/2' 3 - #1/0, 1 #6 G. 150 / 150 75 -deg rating 17N 2' 4 - #2/0, 1 #6 G. 175 / 175 75 -deg rating 17 2" 3 - #2/0, 1 #6 G. 175 /175 75 -deg rating 20N 2" 4 - #3/0, 1 #6 G. 200 / 200 75 -deg rating 20 2' 3 - #3/0, 1 #6 G. 200 / 200 75 -deg rating 22N 2 -1/2" 4 - #4/0, 1 #4 G. 230 / 225 75 -deg rating 22 2" 3 - #4/0, 1 #4 G. 230 / 225 75 -deg rating 25N 3- 4- 250kcmil, 1 #4 G. 255 / 250 75 -deg rating 25 2 1/2- 3- 250kcmil, 1 #4 G. 255 / 250 75 -deg rating 28N 3' 4- 300kcmil, 1 #4 G. 285 / 300 * 75 -deg rating 28 2 1/2" 3- 300kcmil, 1 #4 G. 285 / 300 * 75 -deg rating 3ON 3' 4- 350kcmil, 1 #4 G. 310 / 300 75 -deg rating 30 3' 3- 350kcmil, 1 4 G. 310 / 300 75 -deg rating 33N 3' 4- 400kcmil, 1 2 G. 335/350* 75 -deg rating 33 3" 3- 400kcmil, 1 #2 G. 335/350* 75 -deg rating 35N 3 -1/2- 4- 500kcmil, 1 #2 G. 380 / 350 75 -deg rating 35 3' 3- 500kcmil, 1 #2 G. 380 / 350 75 -deg rating 38N 3 -1/2' 4- 500kcmil, 1 #2 G. 380/400* 75 -deg rating 38 3' 3- 500kcmil, 1 #2 G. 380/400* 75 -deg rating 40N 4- 4- 600kcmil, 1 #2 G. 420 / 400 75 -deg rating 40 3 1/2" 3- 600kcmil, 1 #2 G. 420 / 400 75 -deg rating 42GN 4- 4- 600kcmil, 1 #2 G. 420 / 450* 75 -deg rating 42G 3 1/2" 3- 600kcmil, 1 #2 G. 420 / 450* 75 -deg rating 45N (2) 2 -1/2" 4 - #4/0, 1 #2 G. ea 460 / 450 75 -deg rating 45 (2) 2- 3 - #4/0, 1 #2 G. ea 460 / 450 75 -deg rating 50N (2) 3- 4- 250kemil, 1 #2 G. ea 510 / 500 75 -deg rating 50 (2) 2 1/2" 3- 250kcmil, 1 #2 G. ea 510 / 500 75 -deg rating SON (2) 3" 4- 350kcmil, 1 #1 G. ea 620 / 600 75 -deg rating 60 (2) 3" 3- 350kcmil, 1 #1 G. ea 620 / 600 75 -deg rating BON (2) 4" 4- 600kemil, 1 #1/0 G. ea 840 / 800 75 -deg rating 80 (2) 3 1/2' 3- 600kcmil, 1 #1/0 G. ea 840 / 800 75 -deg rating 100N (3) 3" 4- 400kcmil, 1 #2/0 G. ea 1005 / 1000 75 -deg rating 100 (3) 3- 3- 400kcmil, 1 #2/0 G. ea 1005 / 1000 75 -deg rating 120N (3) 4- 4- 600kcmil, 1 #3/0 G. ea 1260 / 1200 75 -deg rating 120 (3) 3 1/2" 3- 600kcmil, 1 #3/0 G. ea 1260 / 1200 75 -deg rating 16ON (4) 4" 4- 600kcmil, 1 #4/0 G. ea 1680 / 1600 75 -deg rating 160 (4) 3 1/2" 3- 600kcmil, 1 #4/0 G. ea 1680 / 1600 75 -deg rating 20ON (5) 4- 4- 600kcmil, 1 #250kcmil G. ea 2100 / 2000 75 -deg rating 200 (5) 3 1/2" 3- 600kcmil, 1 #250kcmil G. ea 2100 / 2000 75 -deg rating 25ON (6) 4- 4- 600kcmil, 1 #350kcmil G. ea 2520 / 2500 75 -deg rating 250 (6) 3 1/2- 3- 600kcmil, 1 #350kcmil G. ea 2520 / 2500 75 -deg rating 30ON (8) 3 -1/2" 4- 500kcmil, 1 #400kcmil G. ea 3040 / 3000 75 -deg rating 300 (8) 3- 3- 500kcmil, 1 #400kcmil G. ea 3040 / 3000 75 -deg rating 40ON (10)4" 4- 600kcmil, 1 #500kcmil G, ea 4200/4000 75 -deg rating NOTE: Based on THHN insulation, conduit and Appendix C, Table C10m, or Chapter 9, Table 4 and Table 5. of the NEC, 1999 edition. * - Indicates acceptable overcurrent device rating for single feeder. This rating shall not be used for sizing parallel feeders. Load cannot exceed feeder ampacity Suitable as equipment feeder only. Not to be used for panel feeder MAIN SWITCHBOARD 'MSB', 1000A, 65KAIC, 480/277V, 30, 4W F OWNER CHECK METERING -- 2S 200 MAIN PIPE TO UTILITY SERVICE AT EXISTING PRIMARY EXCEPT SWITCHGEAR. NO GROUND ROOFTOP AC -UNIT NTH -1 300A 3P M2 NFW 300A 3P EXISTING SIGNAL WIRING FOR OWNER CHECK METERING 400A 3P TO BUILDING STEEL 40 1 1 225A 100A ) 600A 3P 1 3P- P 3P P SPACE ONE -LINE DIAGRAM SCALE: NONE FLAG NOTES: PSE PAD MOUNTED TRANSFORMER. EXISTING GROUND PER NEC. EXISTING EMON METERS. ® PROVIDE RUSSELLSTOLL #DF2504FRAB OUTLET WITH DSC20 CAP AND LANYARD. "M #" INDICATES METERING NUMBER AND LOCATION OF CTS FOR OWNER CHECK METERS. SEE FLAG NOTE #6. TYPICAL TENANT PANEL ARRANGEMENT (BY OTHERS) PANEL ADD 60A 3P PANEL PANEL PANEL PANEL r2ANEL 2HML BREAKER FOR PANEL 2LP1 2TL1 2TH1 STILE IT 1TL3 - MHHO MLO TRANSFORMER 225KVA 480V- 208/120V i 3014W, K -4 -- TO 1LP1 Y30N 1 t/2' -4/2 & tj2c EXCEPT 1.5 "R & NEUTRAL PANEL 1 TL3 SHALL BE #6 CU EXTEND EXISTING 22" /// IMAGING EQUIPMENT RACI.WAY FROM 30N 10N 30N 15N 15N lON PANEL- - CEILING 51'ACE M4 �` I n nnn PANEL PANEL PANEL PANEL PANELI PANEL WP o) S.T. 'LP1 1'L1 1TL21 1TL77 1THZ 1HXR (- t� C OOA-3P 60N 600A C) 600A 10N -. 200A -3P MLO TVSS MOB ELEVATOR " " -- (30HP) y^ h <1 IN �• MS,M M6� 2"-3#4/0 & 1 #4 /OG X -RAY WOBILE IMAGING - me M49 t 425.778.1530 21911 76th Ave W. Suite 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.t g ba rc h itec ts. co m ACOFFMAN N G I N E E R S 1601 Fifth Avenue, Suite 900 Seattle, WA 98101 -1625 ph 206.623.0717 fax 206.624.3775 coffman.com LASTING creativity 1 results I relationships NOW YELM MOB TENANT IMPROVEMENTS 201 TAHOMA BLVD SE YELM, WA 98597 ONE -LINE DIAGRAM ISSUANCE CONSTRUCTION DOCUMENTS 02/08/2013 SHEET NO E5.11 PROJECT INFORMATION CEI PROJECT NO: _ 1_3107 PROJECT MANAGER: JGJ DRAWN BY: LEN SHEET NO E5.11 PANELSCHEDU4E PANEL'. 1HXR LOCATION: VOLTS 456 Y/ 2]7 P3 W'.4 AMP 400 MI MCBC AID RATING: I4, GOD MOUNT: SURFACE L ^I FLUSH TYPE EXISTING NEW ❑X SME NEUTRAL: 100% FED FROM MAIN SWBD - LOAD LOAD LKT P CIR P CIR P CKi LOAD PANEL SCHEDULE _ - TYPE LOCATION: ass - X IT VOLTS : 480 Y/ 277 BAD_ PANEL:ITH1 3 1 1 A 2 3 100 t 1333 _MISC _X -RAY UNIT _INCH' 3 ) _ _ 31LE IMAGING UNIT MISC 37 -50 MOUNT. F-1 SURFACE ❑X FLUSH MLO� MCB� 3 B _4 OGOESE - AID RATING: _MISC 14,000 _ 31LE IMAGING UNIT -- -- - - -- RE MSC 37ED 2D - -� AMP: 100 C A 5 -8 3 -- 180 -_. 1333 25 nD MISC MISC -_ X RAY UNIT CTSCANNER _ IryOTE 26) -- -- VAPOR ELEV 0.00 KVA FED FROM: DIST PANEL IHML ICI EXISTING NEW EX] BTYLE: '.HEN EQPT - -- 2500 MISC - NEUTRAL:100% .RE _ -- - -- -_ - 10 1. -. - C -- - TYPE __ LOPa LOAD LNi _ P CIR P CIR P CI(i LOPO LOPD <= - - - -. __. - SPACE ------ _. ICCE _ -_ # R # 15 -. BKR M/A ttPE OIRCUIi DEBA CIRLUR DESCRIRION GESTMTR TYPE KVp RKR IS ENTERED HERE AS DIRECT LINK TO LOAD 17 2` 20 1.95_ LTG RECEPTION VW RELAY EXAM MAM - LTG - RELAY, AH -2 / CU -2 _ _ MIR _ 1�] 30 2 1 A 2 LTG -.. IMAGING CONSULT BREAK, LAB,. BLOOD DRAW IMAGING _ -- - - -- - -- - OUR 1,77 - J _ B 4 Y 20 251 _ _ LTG -1.22 dTC 5 17 ao 3 5 C 6 1 z0 - -2G - - -- SPARE _ - -- VAV -1 21 / VAV - _ SPARE -..- -_. -- -517 - -- _ 9 B 10 1 - -20 SPARE - - - - -_ - - - -_- -_ -- HTG 5 66 40 3 11 C _ 12 - - - SPACE - VAV -1 23 V --.- - -- -. HT6 - -- - 566 __ I} q 14 -- SPACE _- __- - HTG 5.66 - 15 B 16 SPACE - _.- - - -- -. -- HTG - - }97 40 3 17 C 18 SPACE - -- _. VAVA 24 _ -- _. - - _. - -- 19 A 20 SPACE - - - - - _ IITG HTG _ 3 9] 3 W _ 21 B 22 - -- SPACE - - VAV-1 25 126 / VAV 127 HTG 40 3 23 _ C 24 SPACE- - - - HUG _583 5 83 25 A 26 SPACE_ _ - - Li 27 _ B 28 _ SPACE_ _ MISC 225 3D 2 29 C 30 _ - - _ SPACE_ HWT -2 MISC L 25 31 A 32 SPACE MTR 0 O9 20 1 33 B 34 SPACE CP _2 2 - -- _ 20 1 35 C 36 SPACE - SP -- 20 1 37 A 38 SPACE SPARE -- SPARE -- - -. 2 0 1 4 B 40 SPACE -- SPACL. 1 IL C 42 SPACE _ -. 0.- - __ -- NEC DEMAND CALCULATIONS - - - LOAD DESCRIPTION LOADNPE CONNECTED CALCULATED [DEMAND ONNECTED PHASE LOADING LIGHTING LTG 446EVA 558 KM (125 %) _C PHASE A. 26 60 OVA HLTG 0.00 KVA 000 KVA (40 %<5OKVA, 20% REST) HOSPITAL LIGHTING 20% HEST) PHASE B: 25 00 HOSPITAL DEPART HREG 0.00 KVA 0.00 KVA ( 40 %<50KVA, PHASED 22 88 KVA LARGEST MOTOR D.00EST 000 KVA (125 %) Ta[el CDnaeoled Land- 7448 <- P,I,d,A tlouble lug loads REMAINING MOTORS MTR 3.63 EVA 3.63 KVA (100 %) . <- Ia.Iad,, double lug loads Call 74 48 Ta GEN PURPOSE RECPT REC 0.00 KVA 0.00 KVA (50% > 10KVA) - COMPUTER RECPT COME O.OD OVA D.00 KVA (100 %) EQUIP / OTHER CONTINUCO%C 450 KVA 450 OVA (100 %) HTG 61.89 KVA 61.89 KVA (100 %) NOTES. HEATING 1 NOTES ELEVATOR ELEV 0.00 SEA 0 -00 KVq ® 100% ?BREAKERS SHOWN WITH AND SHOWN AS A MULTI -POLE KITCHEN EQPT KIT 0.00 KVA 000 KVA ® 65% BREAKER VI WILL BREAKER OR SHALL BE PROVIDED TH EITHTH ER MULTIPLE TILLED HPOLE SINGLE POLE BREAKERS WITH IDENTIFIED HANDLE TIF PEI TOTALS 74 48 KVA 75.60 KVA NEC 210 4(6). 8959 AMPS 9093 AMPS FEEDER I MR BASED CAPACITY: 83 -14 KVA 100, DA <- FEEDER OR OCR CAPOITY' 'Gco -red when UDPIIco6Ie CAPACItt LOAD TVPARGEST: CONNECTED MOTOR LOAD IS ENEERED HERE AS DIRECT LINK TO LOAD usED AVAIL LARGEST MTR LARGEST 'COMB' COMBINATION OF DIFFERENT LOAD TY`>ES ]5"A 83.14 - - HLTGIt HREC HOSPITAL LIGHITNG & RECEPT'S, NON- CONTIITHOUS LOADS ONLY 908A 1r0 PANELSCHEDU4E PANEL'. 1HXR LOCATION: VOLTS 456 Y/ 2]7 P3 W'.4 AMP 400 MI MCBC AID RATING: I4, GOD MOUNT: SURFACE L ^I FLUSH TYPE EXISTING NEW ❑X SME NEUTRAL: 100% FED FROM MAIN SWBD - LOAD LOAD LKT P CIR P CIR P CKi LOAD LOAD KVA C IRLDOO.andTION TYPE KVA ass FRED X IT # BIW MAN TYPE CIRCUIT D EGRPTION 31LE IMAGING UNIT (NOTE 1). BAD_ 3750 150 3 1 1 A 2 3 100 t 1333 _MISC _X -RAY UNIT _INCH' 3 ) _ _ 31LE IMAGING UNIT MISC 37 -50 0.00 - 3 B _4 OGOESE - 1333 _MISC X RAY UNIT _ 31LE IMAGING UNIT -- -- - - -- RE MSC 37ED 2D - -� 5 7 C A 5 -8 3 -- 180 -_. 1333 25 nD MISC MISC -_ X RAY UNIT CTSCANNER _ IryOTE 26) -- -- VAPOR ELEV 0.00 KVA 9 B 10 '.HEN EQPT - -- 2500 MISC - CT SCANNER -._ -__ -. - - - -. .RE _ -- - -- -_ - 10 1. -. 11 C 12 __ 2500 MISC -. CTS _ - - - -. - - - -. - - - -. SCE.- - -_ -_ -_- -. - - -_- - - - -_- - FEEDER / - 13 A _ 14 <= - - - -. __. - SPACE ------ _. ICCE _ -_ v _ LOADTYPENOTES: 15 -. B I6 -..- GESTMTR SPACE - - -_ MOTOR LOAD IS ENTERED HERE AS DIRECT LINK TO LOAD 17 C 18 TYPES n _ SPACE- DEMANDCALCUTATIONS bESCRIPTIOR: HAND TYPE: CONNECTED CALLUTATED OEMWO TING LTG 000PVA LEN 000 KVA (125 %) PITAL LIGHTING HLTG 0.00 KVA 0.00 KVA ( 40 %150KVA, 20% REST) PITAL RECEPT FRED 0 00 KVA 0.00 KVA ( 407.150KVA, 207. REST) ;EST MOTOR 000EPA 0.00 KVA (1257.) AINING MOTORS MTR C 00 KVA 000 KVA (100%) PURPOSE RECPT REC 0 00 KVA 0.00 KVA ( 50% > IOKVA) IPUTER RECPT COMP OGOESE 0.00 KVA (1 OLD) IP / OTHER CONTINUCMB C 227.49 KVA 227.49 KVA (100 %) TING HTG 0.00 KVA O.OD KVA (100%) VAPOR ELEV 0.00 KVA 0.00 KVA 0 100% '.HEN EQPT KIT 000 KVA 040 KVA M CS% TOTALS 227.49 KVA 227 49 KVA 273.63 AMPS 273.63 AMPS FEEDER / OCP BASED CAPACITY: 249.42 KVA 300CA <= FEEDER OR OOP CAPCItt' v rwho, when V111,1able LOADTYPENOTES: GESTMTR LARGEST CBNNECTED MOTOR LOAD IS ENTERED HERE AS DIRECT LINK TO LOAD 'COMB' COMBINATION OF DIFFERENT LOAD TYPES r0 A HRm HoSPITAI IIGHITNG & RECEPT'S. NON CONTINUOUS LOADS ONLY _ CONNECTED PHA' PHASE A'. PHASE B: PHASEC: Total Connected Lend = Lend Checker TMaI = E LOADING ]5 53 OVA 75 83 KVA ]5 83 KVA 227 49 <= dncludes double lug load 22749 <= includes double lug Had NOTES: !LOAD INDICATED IS 50% OF MOMENTARY RATING. 2LOAD INDICATED IS 25% OF MOMENTARY RATING 3LOAD INDICATED 15 10% OF MOMENTARY RATING - 4 PEUVIDE SHUNT TRIP CIRCUIT BREAKER it 425.778.1530 21911 76th Ave W. Suite 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com ACOFFMAN N G I N E E R S 1601 Fifth Avenue, Suite 900 Seattle, WA 98101 -1625 ph 206.623.0717 fax 206.624.3775 coffman.com LASTING creativity I results I relationships YELM MOB TENANT IMPROVEMENTS 201 TAHOMA BLVD SE YELM, WA 98597 PANEL SCHEDULES CONSTRUCTION DOCUMENTS 02108/2013 PROJECT INFORMATION_ CEI PROJECT NO _ _ 13107 PROJECT MANAGER JGJ DRAWN BY: LEN SHEET NO E6.11 opl- ALL INFORMATION ON THIS SHEET IS TO BE CONSIDERED PRELIMINARY AND TENTATIVE AND IS SUBJECT TO CHANGE OR REVISION WITHOUT PRIOR NOTICE. THIS INFORMATION IS FOR PLANNING PURPOSES ONLY. Z [DRAWING CONTENTS MQ W Cl COVER SHEET GN1 GENERAL NOTES O GN2 GENERAL NOTES SECTION A _C Al EQUIPMENT LAYOUT O� A2 EQUIPMENT ELEVATIONS J SECTION S S1 STRUCTURAL LAYOUT SECTION E E1 ELECTRICAL LAYOUT E2 ELECTRICAL SCHEMATIC E3 ELECTRICAL DETAILS E4 CABLE LENGTH DIAGRAM (FOR INTERNAL USE ONLY) Z MQ W .O m O �Z _C O� J Z H H C w Z O o — H w V O F�- Z O v OC w a O o (` > W H W m io o O F LL] H L- r` O W x Z >- 0 LLI 0 IL °� Z W a z m< G v _o W V >W J o >� W Q >- W U. W o GCN U. THESE TOSHIBA PLANS ARE FOR INFORMATIONAL PURPOSES ONLY AND SHALL NOT BE USED FOR ANY PURPOSE OTHER THAN THAT AGREED UPON BETWEEN TOSHIBA AND THE CUSTOMER. THESE SITE PLANS ARE NOT TO BE USED FOR CONSTRUCTION PURPOSES. DATE: 01 -24 -2013 SCALE: NOT TO SCALE PLANNER: G.O. QUOTE: N/A PROJECT NO. 130013266CTF Cl ALL INFORMATION ON THIS SHEET IS TO BE CONSIDERED PRELIMINARY AND TENTATIVE AND IS SUBJECT TO CHANGE OR REVISION WITHOUT PRIOR NOTICE. THIS INFORMATION IS FOR PLANNING PURPOSES ONLY. MINIMUM SITE REQUIREMENTS CHECKLIST NETWORK REQUIREMENTS GENERAL NOTES - CUSTOMER I CONTRACTOR IS RESPONSIBLE FOR THE FOLLOWING UNLESS OTHERWISE NOTED. STRUCTURAL NOTES MONOLITHIC OR LAY -IN CEILING? PLEASE CIRCLE ONE. ELECTRICAL REQUIREMENTS FOR AQUILION REQUIRED FOR THE TOSHIBA EQUIPMENT. THE DESIGN OF ALL STRUCTURAL ELEMENTS PROJECT: SITE INSPECTION DATE: EQUIPMENT DELIVERY DATE: INSPECTED BY: IN ORDER TO ENSURE A TIMELY AND SUCCESSFUL INSTALLATION, IT IS NECESSARY TO COMPLETE THIS FORM PRIOR TO INSTALLATION. PLEASE ASSIST TOSHIBA BY HAVING THE CONTRACTOR OR YOUR REPRESENTATIVE COMPLETE THE FOLLOWING: 01 -08 -13 1 ALL WALLS, FLOORS, AND CEILINGS FINISHED. WALLS PAINTED, FLOORS TILED, NETWORK REQUIREMENTS SEISMIC NOTES AND CEILING GRID WORK AND FIXTURES INSTALLED. - CUSTOMER I CONTRACTOR IS RESPONSIBLE FOR THE FOLLOWING UNLESS OTHERWISE NOTED. 2. MONOLITHIC OR LAY -IN CEILING? PLEASE CIRCLE ONE. A. TOSHIBA RESERVES THE RIGHT TO CHANGE THESE DESIGNS AND SPECIFICATIONS REQUIRED FOR THE TOSHIBA EQUIPMENT. THE DESIGN OF ALL STRUCTURAL ELEMENTS DOORS AND WINDOWS (INCLUDING ALL LEADED DOORS AND GLASS) INSTALLED DUE TO THE LARGE DATA SETS GENERATED BY THE AQUILION'S HIGH SPEED SCANS, AN OPTIMIZED COMPUTER NETWORK ENVIRONMENT IS NECESSARY TO MAINTAIN FAST IMAGE TRANSFER SPEEDS, THE TWO REQUIREMENTS ARE 3 AND LOCKABLE. DOORS TO BE REMOVED PRIOR TO DELIVERY BY CUSTOMER OR MUST BE SPECIFIED BY A LICENSED STRUCTURAL ENGINEER IN ACCORDANCE WITH CONTRACTOR AND REINSTALLED AFTER EQUIPMENT MOVE -IN. RESERVE SECURE 1. HIGH SPEED NETWORK. GIGABIT ETHERNET BETWEEN THE AQUILION AND ITS NETWORK PEERS. 2. UNCLUTTERED NETWORK ENVIRONMENT. THE AQUILION'S IMMEDIATE NETWORK ENVIRONMENT, INCLUDING CONNECTION TO VITAL WORKSTATION AND MCKESSON THIN SLICE IMAGE CACHE, SHOULD BE ON AN ISOLATED NETWORK SEGMENT FREE OF BROADCASTS AND EXTRANEOUS TRAFFIC. THIS CAN BE ACHIEVED BY VLAN, FIR EWALLS, OR SIMILAR TECHNOLOGIES. 'CHNOLOGIES. T.A.M.S. SERVICE NETWORKING SUPPORT TEAM CAN PROVIDE SUGGESTIONS, BUT CUSTOMER WILL NEED TO MAKE ITS OWN INDEPENDENT DETERMINATION ABOUT THE ADEQUACY OF SUCH ITEMS. TOSHIBA WILL NOT BE RESPONSIBLE FOR ANY ISSUES ARISING OUT OF THE NETWORK ENVIRONMENT. B. THE CUSTOMER/CONTRACTOR ROOM FOR STORAGE DURING INSTALLATION. DISTRIBUTION CAPACITY: 150 KVA PLANNER: G. 0. AREA SET ASIDE FOR EQUIPMENT RIGGING AND MOVE -IN. ENVIRONMENTAL IS RESPONSIBLE TO ENSURE THAT ALL APPLICABLE 4. ISSUES ADDRESSED AND RESOLVED PRIOR TO EQUIPMENT DELIVERY (I.E. D. SHOULD THRU - BOLTING METHOD OF ANCHORING BE REQUIRED, IT WILL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE AND INSTALL ALL NECESSARY HARDWARE AND LABOR TO PERFORM THIS TASK. E. THE CUSTOMER /CONTRACTOR IS RESPONSIBLE FOR PULL TESTING OF THE ANCHORS IF SPECIFICATIONS. TOSHIBA WILL PROVIDE GUIDANCE TO DEVELOP SOLUTIONS TO ANY DEFICIENCIES TO THE ENVIRONMENT OR INCOMING POWER. HOWEVER, YOU ARE RESPONSIBLE FOR CORRECTING SUCH DEFICIENCIES, AT NO COST TO TOSHIBA. FAILURE TO CORRECT ANY KNOWN OR DISCOVERED DEFICIENCIES MAY RESULT IN SYSTEM REPAIRS THAT ARE NOT COVERED BY YOUR WARRANTY OR SERVICE CONTRACT. SURGICAL SUITE). B. THE CUSTOMER /CONTRACTOR SHALL FIELD VERIFY ALL EXISTING AND PROPOSED 5_ EQUIPMENT (INGRESS) ROUTES ARE CLEAR AND OBSTACLE FREE. REQUIRED. 01 -08 -13 C. PRIOR ALL CONDUIT, TROUGHING (WITH COVERS), AND BOXES INSTALLED (CLEAN AND 01 -OS -13 6. DUST FREE). GROMMETED OPENINGS, CHASE NIPPLES, RACEWAY DIVIDERS, ETC. TO EQUIPMENT DELIVERY AND INSTALLATION, THE SITE MUST BE 1007 COMPLETE. CIRCUIT BREAKER INSTALLED AND INCOMING POWER (PER POWER QUALITY C. THE TOSHIBA INSTALLATION PROJECT MANAGER SHALL BE NOTIFIED IN WRITING OF ANY 7' REQUIREMENTS) OPERATIONAL AND CONNECTED TO ROOM BREAKER(S). 8, LOCATION OF ALL ELECTRICAL BREAKERS IN POWER CHAIN NOTED. 9 ALL CONTRACTOR- INSTALLED STRUCTURAL SUPPORT DEVICES INSTALLED AND PRIOR TO DELIVERY AND DETERMINE ACCEPTABILITY FOR DELIVERY. TOSHIBA SITE PLANS. LEVELED ACCORDING TO T.A.M.S. SPECIFICATIONS ON SITE PLANS. 10. ROOM LIGHTING INSTALLED AND OPERATIONAL. D. THE DEMOLITION, FABRICATION, AND ERECTION OF SUPPORT STRUCTURES FOR TOSHIBA 11 ENSURE THAT LIGHTING /SPRINKLER HEADS PRESENT NO CONFLICT WITH UNITS KEYBOARDS, OR OTHER ANCILLARY EQUIPMENT SHALL BE SUPPLIED AND INSTALLED MOUNTED TO THE CEILING. 01 -08 -13 12 ENSURE THAT NON- TOSHIBA SUPPLIED EQUIPMENT PRESENT NO CONFLICT WITH BY CUSTOMEFR /CONTRACTOR. WITH THE DESIGN AND SPECIFICATIONS SET FORTH BY THE STRUCTURAL ENGINEER OF UNITS MOUNTED TO THE CEILING. 13, 110V ROOM OUTLETS OPERATIONAL. RECORD. CEILING HEIGHT ALL CONTRACTOR- SUPPLIED CABLES PULLED AND TERMINATED, INCLUDING 14. GROUND WIRE AND GROUND BUS BAR IN TROUGHING AS SPECIFIED IN THE cm TOSHIBA SITE PLANS. TOP, SIDE, ON BACK OF CABINETS, IF REQUIRED. E. DUE TO THE DYNAMIC NATURE OF THE LOAD, BOTH HORIZONTAL AND VERTICAL INTERFACE FOR DIMMING OF ROOM LIGHTS (IF APPLICABLE), WARNING LIGHTS 15. AND DOOR SWITCHES INSTALLED AND INTERFACE AVAILABLE AND CONNECTED ACCELERATION SHOULD BE INCLUDED IN THE DESIGN CALCULATIONS FOR THE SUPPORT RECOMMENDED CEILING HEIGHT: 9' -0" (RELAYS, ETC.). 16. DUST -FREE ENVIRONMENT IN ALL RELATED ROOMS. MINIMUM CEILING HEIGHT: 8' -2 112" 17 HEATING AND AIR - CONDITIONING INSTALLED, OPERATIONAL, AND STABILIZED PER NOT SOLD BY TOSHIBA SUCH AS, PHYSIOLOGICAL MONITORS, LASER CAMERAS, TOSHIBA SITE PLANS. FILTERS TO BE CHANGED 24 HOURS BEFORE DELIVERY. 18. ALL MILLWORK COMPLETE AND INSTALLED. INJECTORS, ETC. SPECIFICATIONS FOR THOSE ITEMS MUST BE OBTAINED FROM THE 19 PLUMBING COMPLETED (INCLUDING GASES, IF APPLICABLE) ACCORDING TO VENDOR AND INCLUDED IN THE DESIGN TOTALS. TOSHIBA SPECIFICATIONS ON SITE PLANS. ELECTRICAL NOTES 20. OPTIONAL COMPUTER FLOORING INSTALLED, IF APPLICABLE. PDESIGN D. THIRD PARTY VENDED ITEMS SUCH AS PROCESSORS, FILM CHANGERS, 21. INJECTORS, GAS PEDESTALS, PHYSIOLOGICAL MONITORING EQUIPMENT, ETC., CUSTOMER I CONTRACTOR IS RESPONSIBLE FOR THE FOLLOWING UNLESS OTHERWISE NOTED. INSTALLED AND OPERATIONAL. WITH TOSHIBA, INSTALLATION PROJECT MANAGER FOR SUITABLE LOCATIONS. TELEPHONE LINES (VOICE AND OPTIONAL MODEM) INSTALLED AND OPERATIONAL. A. THESE SITE PLANS ARE INTENDED TO DEPICT ONLY A CONCEPT OF THE ELECTRICAL 22. A DEDICATED PHONE LINE IS REQUIRED FOR SITES THAT ARE RECEIVING H. CUSTOMER /CVNTRACTOR FLOOR. INNERVISION. 23. ALL UNFINISHED AREAS SEALED OFF TO PREVENT DUST CONTAMINATION. RECEPTACLE FOR TRASH AVAILABLE (LARGE ENOUGH FOR SHIPPING CRATES IF 24 REQUIRED). 25. SUB BASE PLATE(S) INSTALLED (IF REQUIRED). ELEMENTS MUST BE SPECIFIED BY A LICENSED ELECTRICAL ENGINEER IN ACCORDANCE 26. "PD" / "UPS " / "PCDU" INSTALLED AND OPERATIONAL (IF APPLICABLE). CEILING STRUCTURAL SYSTEMS WITH TOSHIBA SPECIFICATION AND ALL APPLICABLE CODES. SEISMIC REQUIREMENTS, AND REQUIRED SEISMIC ANCHORING DEVICES INSTALLED 27 (IF APPLICABLE). 28. NETWORK CONNECTIONS INSTALLED AND OPERATIONAL. 29. ALL APPLICABLE PERMITS OBTAINED. H. IN ORDER TO AVOID COLLISION WITH MOVEABLE TOSHIBA CEILING MOUNTED EQUIPMENT, NOTICE: CUSTOMER MUST COMPLETE ALL ITEMS ON THIS CHECKLIST BEFORE SCHEDULED DELIVERY DATE FOR THE EQUIPMENT. IF CUSTOMER FAILS TO DO SO, DELIVERY MAY BE DELAYED. FURTHERMORE, THE EQUIPMENT WARRANTY MAY BE VOIDED. COMMENTS: SIGNED TOSHIBA: CONTRACTOR: CUSTOMER: CUSTOMER I CONTRACTOR IS RESPONSIBLE FOR THE FOLLOWING UNLESS OTHERWISE NOTED. CUSTOMER I CONTRACTOR IS RESPONSIBLE FOR THE FOLLOWING UNLESS OTHERWISE NOTED. THESE TOSHIBA PLANS ARE FOR GENERAL 01 -08 -13 SUPPLY CONFIGURATION: 3 PHASE DELTA OR WYE / NETWORK REQUIREMENTS SEISMIC NOTES A. THESE SITE PLANS ARE INTENDED TO DEPICT ONLY A CONCEPT OF THE STRUCTURE - CUSTOMER I CONTRACTOR IS RESPONSIBLE FOR THE FOLLOWING UNLESS OTHERWISE NOTED. CUSTOMER I CONTRACTOR IS RESPONSIBLE FOR THE FOLLOWING UNLESS OTHERWISE NOTED. W� FIBER OPTIC CABLES REQUIRE A MINIMUM RADIUS OF 4 1/2". DUCT WORK DESIGN A. TOSHIBA RESERVES THE RIGHT TO CHANGE THESE DESIGNS AND SPECIFICATIONS REQUIRED FOR THE TOSHIBA EQUIPMENT. THE DESIGN OF ALL STRUCTURAL ELEMENTS SUPPLY VOLTAGE: 480V, 100 AMP, 60 Hz DUE TO THE LARGE DATA SETS GENERATED BY THE AQUILION'S HIGH SPEED SCANS, AN OPTIMIZED COMPUTER NETWORK ENVIRONMENT IS NECESSARY TO MAINTAIN FAST IMAGE TRANSFER SPEEDS, THE TWO REQUIREMENTS ARE A. ALL SEISMIC BACKING PLATES, BRACKETS, AND HARDWARE THAT ARE REQUIRED TO ANCHOR ANY TOSHIBA EQUIPMENT WILL BE SUPPLIED AND INSTALLED BY THE CONTRACTOR. CONTRACTOR MUST REFER TO STRUCTURAL ENGINEER DESIGN PRIOR TO WITHOUT NOTICE. MUST BE SPECIFIED BY A LICENSED STRUCTURAL ENGINEER IN ACCORDANCE WITH 1. HIGH SPEED NETWORK. GIGABIT ETHERNET BETWEEN THE AQUILION AND ITS NETWORK PEERS. 2. UNCLUTTERED NETWORK ENVIRONMENT. THE AQUILION'S IMMEDIATE NETWORK ENVIRONMENT, INCLUDING CONNECTION TO VITAL WORKSTATION AND MCKESSON THIN SLICE IMAGE CACHE, SHOULD BE ON AN ISOLATED NETWORK SEGMENT FREE OF BROADCASTS AND EXTRANEOUS TRAFFIC. THIS CAN BE ACHIEVED BY VLAN, FIR EWALLS, OR SIMILAR TECHNOLOGIES. 'CHNOLOGIES. T.A.M.S. SERVICE NETWORKING SUPPORT TEAM CAN PROVIDE SUGGESTIONS, BUT CUSTOMER WILL NEED TO MAKE ITS OWN INDEPENDENT DETERMINATION ABOUT THE ADEQUACY OF SUCH ITEMS. TOSHIBA WILL NOT BE RESPONSIBLE FOR ANY ISSUES ARISING OUT OF THE NETWORK ENVIRONMENT. B. THE CUSTOMER/CONTRACTOR TOSHIBA P IF T S EC ICA IONS AND ALL APPLICABLE CODES. DISTRIBUTION CAPACITY: 150 KVA PLANNER: G. 0. QUOTE: N/A IS RESPONSIBLE TO ENSURE THAT ALL APPLICABLE ADDITIONALLY, REMOTE SERVICE AND SUPPORT IS PROVIDED BY VPN. TOSHIBA REQUIRES FULL-TIME BIDIRECTIONAL CONNECTION. PLEASE SEE TOSHIBA CONNECTIVITY WHITE PAPER FOR SUPPORTED VPN METHODOLOGIES. CONNECTION. ANCILLARY EQUIPMENT VENDORS SUCH AS VITAL AND MCKESSON, MAY RIEQUIRE THEIR OWN REMOTE SERVICE CONNECTION, D. SHOULD THRU - BOLTING METHOD OF ANCHORING BE REQUIRED, IT WILL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE AND INSTALL ALL NECESSARY HARDWARE AND LABOR TO PERFORM THIS TASK. E. THE CUSTOMER /CONTRACTOR IS RESPONSIBLE FOR PULL TESTING OF THE ANCHORS IF SPECIFICATIONS. TOSHIBA WILL PROVIDE GUIDANCE TO DEVELOP SOLUTIONS TO ANY DEFICIENCIES TO THE ENVIRONMENT OR INCOMING POWER. HOWEVER, YOU ARE RESPONSIBLE FOR CORRECTING SUCH DEFICIENCIES, AT NO COST TO TOSHIBA. FAILURE TO CORRECT ANY KNOWN OR DISCOVERED DEFICIENCIES MAY RESULT IN SYSTEM REPAIRS THAT ARE NOT COVERED BY YOUR WARRANTY OR SERVICE CONTRACT. FEDERAL, STATE, AND LOCAL CODES AND ORDINANCES ARE COMPLIED WITH. B. THE CUSTOMER /CONTRACTOR SHALL FIELD VERIFY ALL EXISTING AND PROPOSED 01 -08 -13 0 REQUIRED. 01 -08 -13 C. PRIOR DIMENSIONS AND SITE CONDITIONS PRIOR TO COMMENCING CONSTRUCTION. 01 -OS -13 4.0 TO EQUIPMENT DELIVERY AND INSTALLATION, THE SITE MUST BE 1007 COMPLETE, CLEAN AND FREE OF DUST. CUSTOMER /CONTRACTOR AND TOSHIBA C. THE TOSHIBA INSTALLATION PROJECT MANAGER SHALL BE NOTIFIED IN WRITING OF ANY VIBRATION SPECIFICATION m INSTALLATION PROJECT MANAGER MUST COMPLETE A SITE WALK THROUGH 1 WEEK FIELD CONDITIONS ENCOUNTERED THAT ARE CONTRADICTORY TO THOSE SHOWN IN THE PRIOR TO DELIVERY AND DETERMINE ACCEPTABILITY FOR DELIVERY. TOSHIBA SITE PLANS. GANTRY D. ANY CABINETNY THAT MAY BE REQUIRED TO HOUSE VIDEO RECORDERS, MONITORS D. THE DEMOLITION, FABRICATION, AND ERECTION OF SUPPORT STRUCTURES FOR TOSHIBA 0.98 M S z 0.1 G OR LESS KEYBOARDS, OR OTHER ANCILLARY EQUIPMENT SHALL BE SUPPLIED AND INSTALLED EQUIPMENT SHALL BE PERFORMED BY THE CUSTOMER /CONTRACTOR IN ACCORDANCE 01 -08 -13 BY CUSTOMEFR /CONTRACTOR. WITH THE DESIGN AND SPECIFICATIONS SET FORTH BY THE STRUCTURAL ENGINEER OF RECORD. CEILING HEIGHT E PROVIDE ADE(DUATE VENTILATION WITHIN CABINETRY AND INSTALL AXIAL FANS ON THE cm TOP, SIDE, ON BACK OF CABINETS, IF REQUIRED. E. DUE TO THE DYNAMIC NATURE OF THE LOAD, BOTH HORIZONTAL AND VERTICAL ACCELERATION SHOULD BE INCLUDED IN THE DESIGN CALCULATIONS FOR THE SUPPORT RECOMMENDED CEILING HEIGHT: 9' -0" �� E THESE TOSHIE3A SITE PLANS DO NOT INDICATE EQUIPMENT REQUIREMENTS FOR ITEMS STRUCTURE AS WELL AS ANCHORING AND THRU- BOLTING FOR THE TOSHIBA EQUIPMENT. MINIMUM CEILING HEIGHT: 8' -2 112" O NOT SOLD BY TOSHIBA SUCH AS, PHYSIOLOGICAL MONITORS, LASER CAMERAS, 01 -08 -13 INJECTORS, ETC. SPECIFICATIONS FOR THOSE ITEMS MUST BE OBTAINED FROM THE E IN THE INTEREST OF SAFETY, TOSHIBA RESERVES THE RIGHT TO DELAY INSTALLATION VENDOR AND INCLUDED IN THE DESIGN TOTALS. COMMENCEMENT MMNCEMENT UNTIL STRUCTURAL DRAWINGS STAMPED BY THE STRUCTURAL ELECTRICAL NOTES W �■ ) PDESIGN D. G. DESIGN, FABRICATE, AND INSTALL MEDICAL GAS PEDESTAL, IF REQUIRED. CONSULT CUSTOMER I CONTRACTOR IS RESPONSIBLE FOR THE FOLLOWING UNLESS OTHERWISE NOTED. WITH TOSHIBA, INSTALLATION PROJECT MANAGER FOR SUITABLE LOCATIONS. G. UNDER NO CIRCUMSTANCE SHOULD THE TOSHIBA EQUIPMENT BE INSTALLED ON A WOOD A. THESE SITE PLANS ARE INTENDED TO DEPICT ONLY A CONCEPT OF THE ELECTRICAL H. CUSTOMER /CVNTRACTOR FLOOR. REQUIREMENTS FOR THE TOSHIBA EQUIPMENT, THE DESIGN OF ALL ELECTRICAL SHALL BE RESPONSIBLE FOR PROVIDING AN OPERATING ELEMENTS MUST BE SPECIFIED BY A LICENSED ELECTRICAL ENGINEER IN ACCORDANCE PHONE IN THE CONTROL ROOM AT THE TIME TOSHIBA EQUIPMENT INSTALLATION CEILING STRUCTURAL SYSTEMS WITH TOSHIBA SPECIFICATION AND ALL APPLICABLE CODES. z BEGINS. H. IN ORDER TO AVOID COLLISION WITH MOVEABLE TOSHIBA CEILING MOUNTED EQUIPMENT, - ALL CEILING FIXTURES SUCH AS LAMPS, SMOKE DETECTORS, SPRINKLERS, ETC. MUST BE g, IN ACCORDANCE WITH NEC ARTICLE 517- 72(B), THE EQUIPMENT CIRCUIT BREAKER(S) I. CUSTOMERCING ACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE LIGHTING FLUSH MOUNTED. MUST BE LOCATED SO THAT THEY SHALL BE OPERABLE FROM A LOCATION READILY FOR SERVICING OF EQUIPMENT IN ALL AREAS OF THE INSTALLATION. ACCESSIBLE FROM THE CONTROL AREA. IF THIS IS IMPOSSIBLE OR IMPRACTICAL, THE UNISTRUT NOTES USE OF A SHUNT TRIP TYPE BREAKER WILL BE NECESSARY TO SATISFY THIS J. THE CUSTOMER /CONTRACTOR SHALL BE RESPONSIBLE FOR ANY AND ALL COSTS I. CEILING UNISTRUT SUPPORT STRUCTURES TO BE DESIGNED BY OTHERS BASED ON REQUIREMENT. THE EMERGENCY OFF BUTTON FOR THE SHUNT TRIP SHOULD REQUIRED FOR THE ENGINEERING AND /OR REMOVAL OF ANY HAZARDOUS MATERIALS SPECIFICATIONS SHOWN ON TOSHIBA SITE PLANS (IF APPLICABLE). BE LOCATED IN THE CONTROL AREA. SUCH AS ASBESTOS. J. UNISTRUT OR EQUIVALENT CHANNEL SUPPORT SYSTEM TO BE SUPPLIED AND INSTALLED C. THE CUSTOMER /CONTRACTOR SHALL SUPPLY AND INSTALL ALL CIRCUIT BREAKERS, K. CUSTOMER /CQNTRACTOR SHALL SUPPLY AND INSTALL MATERIALS AND OTHER BY CUSTOMER /CONTRACTOR (IF APPLICABLE). CONDUITS, JUNCTION BOXES, DUCTS, ETC. SPECIFIED HEREIN. FEATURES SPE= CIFIED IN THE TOSHIBA SITE PLANS. CUSTOMER /CONTRACTOR SHALL SUPPLY AND INSTALL ALL COUNTERTOPS, SINKS, CASE WORK AND CABINETS K. UNISTRUT ARE TO BE P1001 OR P5001 OR EQUIVALENT, MOUNTED FLUSH WITH D. THE TOSHIBA SITE PLANS DO NOT SPECIFY ELECTRICAL REQUIREMENTS FOR z SPECIFIED IN THE TOSHIBA SITE PLANS. FINISHED CEILING. ALL UNISTRUT ARE TO BE MOUNTED PARALLEL AND LEVEL WITH A EQUIPMENT NOT SOLD BY TOSHIBA. THESE REQUIREMENTS MUST BE OBTAINED BY O MAXIMUM DEVIATION OF 1/16 ". UNISTRUT IS TO BE CAPABLE OF SUPPORTING LOAD THE VENDOR. a PLUMBING REQUIREMENTS OF TOSHIBA EQUIPMENT. UNISTRUT LOAD REQUIREMENTS AND DESIGN ARE L PLUMBING IS NOT REQUIRED FOR THIS TOSHIBA EQUIPMENT. THE RESPONSIBILITY OF THE STRUCTURAL ENGINEER OF RECORD. E TOSHIBA WILL SUPPLY INTERCONNECTING CABLES FOR THE TOSHIBA EQUIPMENT. w TOSHIBA WILL INSTALL IF LOCAL TRADE LABOR PERMITS. o M. IT IS RECOMMENDED THAT A SINK BE PROVIDED FOR USE BY PERSONNEL. 01 -08 -13 F. EXCEPT FOR THEIR USE IN POWER LINE CONNECTIONS TO EQUIPMENT CABINETS, SITE CONDITIONS SPECIM AL NOTES FLEXIBLE CONDUIT SHALL NOT BE USED IN THIS INSTALLATION. ONLY FACTORY N. DIMENSIONS TO WALLS AND OR OTHER ROOM FEATURES, EXCEPT FOR NOTED COLUMN V CONDUIT ELBOWS SHALL BE USED. AND BEAM CENTER LINES SHALL BE FROM FINISHED SURFACES. SPECIAL SEISMIC CERTIFICATION 0. CT GANTRY SF30ULD A. THE FOLLOWING COMPONENTS HAVE SPECIAL SEISMIC CERTIFICATION: G. DUCT WORK SHALL BE PROVIDED WITH SWEEP ELBOWS. NOT BE INSTALLED WITHIN 0.5 MAGNETIC GAUSS FIELD. A.A. OSP- 0174 -10 H. ALL JUNCTION BOXES AND DUCTS THAT PENETRATE THE FLOOR SHALL BE P. THE WINDOW FOR MONITORING THE SCAN ROOM SHOULD BE IN FRONT OF OR ON WATERPROOF TYPE AND PROVIDED WITH GASKETED WATERPROOF COVERS. ALL FLOOR THE SIDE OF THE CONSOLE DESK. THE LOWEST WINDOW FRAME SHOULD BE 36" GANTRY JUNCTION BOXES AND DUCT COVERS SHALL BE CAPABLE OF SUPPORTING A ABOVE THE FLOOR FOR EASY PATIENT MONITORING. AQUILION ONE SERIES: CGGT 1A CONCENTRATED LOAD OF 200 LBS. AQUILION PREMIUM IUM 320 SERIES: COOT -0 GGT- 024A/1B Q. A DOOR BETWEEN THE SCAN AND CONTROL ROOM IS RECOMMENDED. AQUILION LB: CGGT- 020A /lC I. GROMMETED OPENINGS ARE SHOWN FOR REFERENCE PURPOSES ONLY. VERIFY SIZE O AQUILION OR: CGGT- C24A /1B AND LOCATION WITH TOSHIBA REPRESENTATIVE. ALL GROMMETED OPENINGS SHALL o R. THE INSTALLATION ALTITUDE SHOULD BE NO MORE THAN 3,280 FT. (1,000 M) ABOVE AQUILION 64: CGGT- 021A /1A HAVE NO SHARP EDGES. SEA LEVEL. PRIOR CONSULTATION IS REQUIRED FOR INSTALLATIONS HIGHER THAN AQUILION 32: CGGT- 021A/2A 3,280 FT. (1,000 M). AQUILION 16/8/4: CGGT- 018A /iC J. ALL CHASE & GROMMETED OPENINGS SHALL HAVE PLASTIC /NYLON BUSHINGS. PATIENT COUCH TRANSPORT REQUIREMENTS AQUILION ONE /PREMIUM STANDARD: CBTB- 021A/1A K. ALL WALL DUCT WORK SHALL HAVE A MINIMUM OF THREE COMPARTMENTS. EQUIPMENT INGRE`,35 ROUTE MUST BE CHECKED PRIOR TO EQUIPMENT DELIVERY TO AQUILION CX: CBTB- 023A/1A TRANSITIONS SUCH AS HORIZONTAL TO VERTICAL WALL DUCT OR WALL DUCT TO ENSURE THE LARGEST AND HEAVIEST ITEMS OF EQUIPMENT CAN BE ACCOMMODATED, LATERAL SHIFT KIT: CALU- 001A /iC (OPTIONAL) JUNCTION BOXES MUST BE REVIEWED ON AN INDIVIDUAL BASIS WITH THE PRIOR TO EQUIPMENT DELIVERY. DIMENSIONS OF DOORWAYS SHOULD BE NO LESS THAN " AQUILION LB STANDARD: CBTB- 020A /1A INSTALLATION PROJECT MANAGER. LOCAL CODES. MAY REQUIRE THE USE OF 4 -0" CLEAR IN WIDTH. CONTACT THE TOSHIBA INSTALLATION PROJECT MANAGER FOR CROSS -OVER TUNNELS OR OTHER SUCH DEVICES TO MAINTAIN CABLE SEPARATION. DETAILS PERTAINING TO THE LARGEST AND HEAVIEST COMPONENTS FOR THIS INSTALLATION AQUILION LB COMPACT: CBTB- 020B /lA 0 (SEE DETAIL 4, SUEET GN2). AQUILION 64/32 STANDARD: CBTB -019A L. ALL DUCT AND CONDUITS SHALL BE ELECTRICALLY BONDED AS A GROUNDING PATH IN AQUILION 64/32 COMPACT: CBTB -019B ACCORDANCE WITH NEC ARTICLE 517- 13(B). AQUILION 16/8/4: CBTB- 016A /1A NETWORKING REQUIREMENTS POWER DISTRIBUTOR: CETF- 006A /2A M. CUSTOMER /CONTRACTOR SHALL SUPPLY AND INSTALL GREENLEE NYLON MEASURING LLJ S. NETWORK REQUIREMENTS WILL VARY BY SITE. TOSHIBA REPRESENTATIVE WILL REQUIRE RECONSTRUCTION UNIT(S) PULL STRING OR EQUIVALENT IN ALL CONDUITS AND CLOSED DUCT WORK. I— Y_ DICOM DEVICE INFORMATION. ADDITIONAL I.P. ADDRESSES, AND I.T. DEPARTMENT AQUILION ONE: CKCN- 015A /1A J Q J On CONTACT INFONMATION PRIOR TO INSTALLATION. AQUILION PREMIUM: CKCN 015A /3A N. CONDUIT RUNS SHOWN ARE FOR REFERENCE ONLY. ALL CONDUIT RUNS MUST TAKE X AQUILION LB: CKCN -012C 5A THE SHORTEST MOST DIRECT ROUTE POSSIBLE. 0 AQUILION CX/64/32: CKCN- 012B /5A 0. CONDUIT RUNS MAY HAVE A MAXIMUM OF (3) 90' BENDS. W J : 00 AQUILION 16/8/4: cKCN- 012c /7A � � 0 CPU AQUILION ONE: CKCN- P. 110VAC GROUNDED OUTLETS SHALL BE PROVIDED ON WALLS NEAR THE TOSHIBA V J 015A /1A EQUIPMENT FOR USE DURING EQUIPMENT SERVICE. Z J Q AQUILION PREMIUM: CKCN- 015A/3A W m AQUILION LB: CKCN- 012C/5A Q. CUSTOMER /CONTRACTOR MUST SUPPLY AND INSTALL ALL INCOMING POWER CABLES �♦ y 0 AQUILION CX/64/32: CKCN- 012B /5A FROM CIRCUIT BREAKER(S) TO TOSHIBA EQUIPMENT CONNECTION POINT. CABLE TYPE 0 AQUILION 16/8/4: CKCN- 012C/7A MUST BE MTW MULTI - STRAND COPPER - NO ALUMINUM IS PERMITTED. CABLE SIZE > LCD MONITORS MUST BE IN ACCORDANCE WITH TOSHIBA POWER QUALITY REQUIREMENTS. (SEE SHEET G {ii J KEYBOARDS MOUSE E ?) 0 W A. P. CSP- 0162 -10 R CUSTOMER /CONTRACTOR IS TO SUPPLY AND INSTALL ALL NECESSARY HARDWARE TO 0 >_ PCDU - GROUP 1 ENCLOSURES (AS APPLICABLE) ENCLOSE INCOMING POWER CABLES IN FLEXIBLE WATER TIGHT CONDUIT FROM CIRCUIT A. C. OSP- 0119 -10 BREAKER(S) TO TOSHIBA EQUIPMENT CABINET(S). G8000 UNINTERRUPTIBLE POWER SUPPLY - G8000 (AS APPLICABLE) A.D. OSP- 0088 -10 S. ANY CHANGES IN THE LOCATION OR TYPE OF CONDUIT, DUCT WORK, JUNCTION 0 BAT - DC43 (WHEN PAIRED WITH G8000) (AS APPLICABLE) BOXES, ETC, MUST BE SUBMITTED IN WRITING TO THE TOSHIBA INSTALLATION PROJECT N BAT - BC55 (WHEN PAIRED WITH 9390) (AS APPLICABLE) MANAGER FOR APPROVAL. A. E. OSP- 0013 -10 UPS - 9390 160 KVA (AS APPLICABLE) T. A SEPARATE CIRCUIT, FED FROM THE FACILITY RADIOLOGY PANEL OR A MAIN SERVICE PANEL IS REQUIRED. USE OF A SUB PANEL WITH LOADS SUCH AS ELEVATORS, HVAC, B. WEIGHTS SHOWN ON THE OISE DOCUMENTS ARE GENERALLY A MAXIMUM AND THE WEIGHTS MOTORS, ETC. IS NOT PERMITTED. SHOWN ON THESE SITE PLANS REFLECT THE EQUIPMENT AS ORDERED. THESE TOSHIBA PLANS ARE FOR 01 -08 -13 01 -08 -13 U. ALL DUCT WORK MAKING A 90° ANGLE MUST BE CHAMFERED FOR CABLE ACCESS. V. JUNCTION BOX SIZES MAY BE INCREASED AS NEEDED (WITH THE EXCEPTION OF THE "PD ", "PCDU ", OR "IJPS" JUNCTION BOX IF APPLICABLE). INFORMATIONAL PURPOSES ONLY AND SHALL NOT BE USED FOR ANY PURPOSE OTHER THAN THAT AGREED UPON BETWEEN TOSHIBA AND THE CUSTOMER. THESE SITE PLANS ARE NOT TO BE USED NETWORK REQUIREMENTS SEISMIC NOTES - CUSTOMER I CONTRACTOR IS RESPONSIBLE FOR THE FOLLOWING UNLESS OTHERWISE NOTED. CUSTOMER I CONTRACTOR IS RESPONSIBLE FOR THE FOLLOWING UNLESS OTHERWISE NOTED. W� FIBER OPTIC CABLES REQUIRE A MINIMUM RADIUS OF 4 1/2". DUCT WORK DESIGN FOR CONSTRUCTION PURPOSES. DATE: 01 -24 -2013 DUE TO THE LARGE DATA SETS GENERATED BY THE AQUILION'S HIGH SPEED SCANS, AN OPTIMIZED COMPUTER NETWORK ENVIRONMENT IS NECESSARY TO MAINTAIN FAST IMAGE TRANSFER SPEEDS, THE TWO REQUIREMENTS ARE A. ALL SEISMIC BACKING PLATES, BRACKETS, AND HARDWARE THAT ARE REQUIRED TO ANCHOR ANY TOSHIBA EQUIPMENT WILL BE SUPPLIED AND INSTALLED BY THE CONTRACTOR. CONTRACTOR MUST REFER TO STRUCTURAL ENGINEER DESIGN PRIOR TO MUST ACCOMMODATE THIS REQUIREMENT. 01 -08 -13 1. HIGH SPEED NETWORK. GIGABIT ETHERNET BETWEEN THE AQUILION AND ITS NETWORK PEERS. 2. UNCLUTTERED NETWORK ENVIRONMENT. THE AQUILION'S IMMEDIATE NETWORK ENVIRONMENT, INCLUDING CONNECTION TO VITAL WORKSTATION AND MCKESSON THIN SLICE IMAGE CACHE, SHOULD BE ON AN ISOLATED NETWORK SEGMENT FREE OF BROADCASTS AND EXTRANEOUS TRAFFIC. THIS CAN BE ACHIEVED BY VLAN, FIR EWALLS, OR SIMILAR TECHNOLOGIES. 'CHNOLOGIES. T.A.M.S. SERVICE NETWORKING SUPPORT TEAM CAN PROVIDE SUGGESTIONS, BUT CUSTOMER WILL NEED TO MAKE ITS OWN INDEPENDENT DETERMINATION ABOUT THE ADEQUACY OF SUCH ITEMS. TOSHIBA WILL NOT BE RESPONSIBLE FOR ANY ISSUES ARISING OUT OF THE NETWORK ENVIRONMENT. FABRICATION. B. THE STRUCTURAL ENGINEER OF RECORD SHALL BE RESPONSIBLE FOR DESIGNING SEISMIC ANCHORS PER TITLE -24 AND MUST BE REVIEWED BY TOSHIBA INSTALLATION PROJECT MANAGER PRIOR TO SUBMISSION FOR STATE AND LOCAL APPROVAL. C. THE CONTRACTOR IS RESPONSIBLE FOR INSTALLING ALL "HILTI "' ANCHORS TO ANCHOR TOSHIBA EQUIPMENT TO CONCRETE FLOOR. "HILL HDI "' DROP -IN TYPE ANCHORS ARE REQUIRED TO ANCHOR DOWN EQUIPMENT CABINETS, CONSOLES, AND COMPUTERS. "HILL KWIK BOLT II" ARE USED TO ANCHOR DOWN FLOOR MOUNTED EQUIPMENT, AS APPLICABLE / PER STRUCTURAL ENGINEER OF RECORD. TOSHIBA POWER & ENVIRONMENTAL QUALITY NOTIFICATION I ASSESSMENT X. FOR YOUR SYSTEM TO PERFORM TO THE RELIABILITY AND QUALITY STANDARDS YOU EXPECT FROM TOSHIBA, IT IS CRUCIAL THAT THE ENVIRONMENT IN WHICH THE SYSTEM IS OPERATING MEET THE REQUIREMENTS STATED WITHIN THE TOSHIBA PUBLISHED SPECIFICATIONS AS DOCUMENTED IN YOUR TOSHIBA SITE PLAN. TO ENSURE QUALITY PERFORMANCE, TOSHIBA, WITH NO COST TO YOU, WILL CHECK THE TEMPERATURE, HUMIDITY, AND INCOMING POWER OF YOUR SITE PRIOR TO E AND AFTER THE INSTALLATION OF TOSHIBA EQUIPMENT. TOSHIBA WILL PROVIDE A WRITTEN REPORT DETAILING THE STATUS OF YOUR SITE'S ENVIRONMENT AND INCOMING POWER. SHOULD ANY FAILURE TO MEET TOSHIBA'S SPECIFICATIONS BE IDENTIFIED PRE AND POST INSTALLATION, THE FACILITY WILL BE REQUIRED TO CORRECT THEM TO MEET TOSHIBA PUBLISHED SCALE: NOT TO SCALE PLANNER: G. 0. QUOTE: N/A PROJECT NO. q 1 300 1 3266CTF ADDITIONALLY, REMOTE SERVICE AND SUPPORT IS PROVIDED BY VPN. TOSHIBA REQUIRES FULL-TIME BIDIRECTIONAL CONNECTION. PLEASE SEE TOSHIBA CONNECTIVITY WHITE PAPER FOR SUPPORTED VPN METHODOLOGIES. CONNECTION. ANCILLARY EQUIPMENT VENDORS SUCH AS VITAL AND MCKESSON, MAY RIEQUIRE THEIR OWN REMOTE SERVICE CONNECTION, D. SHOULD THRU - BOLTING METHOD OF ANCHORING BE REQUIRED, IT WILL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE AND INSTALL ALL NECESSARY HARDWARE AND LABOR TO PERFORM THIS TASK. E. THE CUSTOMER /CONTRACTOR IS RESPONSIBLE FOR PULL TESTING OF THE ANCHORS IF SPECIFICATIONS. TOSHIBA WILL PROVIDE GUIDANCE TO DEVELOP SOLUTIONS TO ANY DEFICIENCIES TO THE ENVIRONMENT OR INCOMING POWER. HOWEVER, YOU ARE RESPONSIBLE FOR CORRECTING SUCH DEFICIENCIES, AT NO COST TO TOSHIBA. FAILURE TO CORRECT ANY KNOWN OR DISCOVERED DEFICIENCIES MAY RESULT IN SYSTEM REPAIRS THAT ARE NOT COVERED BY YOUR WARRANTY OR SERVICE CONTRACT. G N 1 01 -08 -13 01 -08 -13 REQUIRED. 01 -08 -13 01 -08 -13 ALL INFORMATION ON THIS SHEET IS TO BE CONSIDERED PRELIMINARY AND TENTATIVE AND IS SUBJECT TO CHANGE OR REVISION WITHOUT PRIOR NOTICE. THIS INFORMATION IS FOR PLANNING PURPOSES ONLY. CUSTOMER TO PROVIDE THE NECESSARY HVAC REQUIREMENTS FOR THE TOSHIBA EQUIPMENT TO OPERATE PROPERLY. AMBIENT TEMPERATURE SHOULD BE 68 ° -74° F WITH EQUIPMENT HEAT LOADS (SEE EQUIPMENT LEGEND SHEET Al) HUMIDITY RANGE OF 40 -709 NON- CONDENSING A. STATED AMBIENT TEMPERATURE IS TO BE PROVIDED AND MAINTAINED AS SPECIFIED, ALL PRIOR TO GANTRY DELIVERY, CHECK THE DELIVERY ENTRANCE, O CALCULATIONS ARE TO UTILIZE TOSHIBA PROVIDED HEAT OUTPUT SPECIFICATIONS OF CORRIDOR WIDTH, ELEVATOR CAPACITY, ETC. TO ENSURE EASE r. EQUIPMENT. A/C SUPPLY OUTLET OF DELIVERY. COMPENSATION FOR ADDITIONAL REQUIREMENTS •1111111111 EXCLUSION ZONE OF RIGGING EQUIPMENT USED (I.E. SIZE AND MANEUVERABILITY) B. A MINIMUM OF 10 AIR CHANGES PER HOUR IS SUGGESTED, CONSULT LOCAL CODE. I MUST BE CONSIDERED WHEN REVIEWING THE FOLLOWING. C. AIR SUPPLY DUCTS SHOULD NOT BE PLACED DIRECTLY OVER EXAMINATION TABLES FOR �� � � PATIENT COMFORT (SEE DETAIL 2, SHEET GN2). — — 0 D. EQUIPMENT IN ENCLOSED SPACES SUCH AS EQUIPMENT ROOMS, TRANSFORMER CLOSETS C AND COMPUTER ROOMS MUST BE PROVIDED WITH ADEQUATE VENTILATION. — �, E. THE AIRFLOW THROUGH TOSHIBA EQUIPMENT CABINETS IS FROM BOTTOM TO TOP. a F. WHERE POSSIBLE, AIR CONDITIONING SUPPLY OUTLETS SHOULD BE LOCATED AT FLOOR LEVEL, NO AIR CONDITIONING OUTLET SHOULD BE WITHIN THE EXCLUSION ZONE SHOWN — - - ----- 42 O BELOW AND AT NO TIME SHOULD THE CT SYSTEM BE EXPOSED TO DIRECT AIRFLOW. (EAR � Qi G. RETURN GRILLES ARE TO BE INSTALLED IN THE CEILING. H. A/C SUPPLY OUTLET TO BE PROVIDED BY CUSTOMER AT FLOOR LEVEL AT CONTROL ROOM j O DESK.4' I. DUE TO HEAT GENERATED BY THE "CPU" UNIT, ADDITIONAL VENTILATION IN THE CONTROL AREA IS REQUIRED. CUSTOMER /CONTRACTOR PROVIDED FAN(S) MAY BE NECESSARY BELOW THE DESKTOP FOR TECHNICIAN COMFORT. THE "CPU" UNIT SHOULD NOT BE ENCLOSED IN O z CASEWORK. SUPPLY OUTLET EXCLUSION ZONE FRONT 51or RECOMMENDED TEMPERATURE CONDITIONS SCALE: 1/4" - 1' -O° 01 -08 -13 IN CT SCAN ROOM n -- ' 4' -1" 5' -10" I o ___ _ ___ _ `b A. CABINET SHOULD BE LIFTED FROM THE FRONT. O X,X 1.5 FRS TOLERANCE: t3 °F CEILING MOUNTED EQUIPMENT EXCLUSION ZONE B. CABINET SHOULD NOT BE LIFTED FROM THE SIDES. a M-7, C. RECOMMENDED DOOR SIZE IS 48" CLEAR IN WIDTH. MINIMUM DOOR SIZE IS 42" CLEAR IN WIDTH cwi TIMER ON A/C ON SCAN START TIME (36° DOOR IS NOT ACCEPTABLE). M J. IN GENERAL, THE SCANNING ROOM MUST BE PROVIDED WITH AN INDEPENDENT AIR CONDITIONING SYSTEM. EVEN IF THE ROOM IS MAINTAINED WITHIN THE PERMISSIBLE TEMPERATURE RANGE, GRADUAL TEMPERATURE SHIFTS (FOR EXAMPLE, A SLOW INCREASE MINIMUM DELIVERY REQUIREMENTS IN ROOM TEMPERATURE FROM MORNING TO EVENING) MAY ADVERSELY AFFECT SYSTEM MINIMUM HEIGHT OF ENTRY WAY DOORS: 6' -0° PERFORMANCE. THEREFORE, THE ROOM TEMPERATURE MUST BE KEPT UNDER CONSTANT CONTROL (WITHIN f3 °F) AS SHOWN IN THE ABOVE FIGURE. A. CEILING MOUNTED EQUIPMENT MUST BE POSITIONED TO AVOID INTERFERENCE WITH GANTRY. MINIMUM WIDTH OF ENTRY WAY DOORS: Y -7 1/2" K. THE AIR CONDITIONING SYSTEM IN THE SCANNING ROOM MUST BE INSTALLED SO THAT THE B. EQUIPMENT IS TO BE A MINIMUM OF 10" ABOVE THE RAISED GANTRY COVER SEE DETAIL MINIMUM WIDTH OF CORRIDOR: 6' -7" CT SYSTEM IS NOT EXPOSED TO DIRECT AIRFLOW. FAILURE TO DO SO MAY CAUSE THE 11 SHEET A2). ( o TEMPERATURE INSIDE THE CT SYSTEM TO FLUCTUATE, POSSIBLY AFFECTING THE DISPLAYED IMAGES ADVERSELY. C. OVERHEAD COUNTERPOISE SYSTEMS CAN BE INSTALLED OVER GANTRY ISOCENTER IF THE PLATE IS MOUNTED AT A HEIGHT SUCH THAT THE BOTTOM OF THE POST DOES NOT INTERFERE WITH THE GANTRY (HEIGHT OF GANTRY + 10" CLEARANCE + POST LENGTH = MOUNTING PLATE HEIGHT ABOVE FINISHED FLOOR). OHVAC REQUIREMENTS O RECOMMENDED GANTRY 1 3 CEILING MOUNTED EQUIPMENT O DELIVERY REQUIREMENTS �5 )UPS DELIVERY REQUIREMENTS o SCALE: NOT TO SCALE 01 -08 -13 SCALE: 1/4" = 1' -0" 01 -08 -13 SCALE: NOT TO SCALE 01 -08 -13 \� SCALE: NOT TO SCALE 01 -08 -13 C W J _D 0) W X cn Ln > 00 WJ z m Q o OW o o� �g Q =w Q 0 c� THESE TOSHIBA PLANS ARE FOR INFORMATIONAL PURPOSES ONLY AND SHALL NOT BE USED FOR ANY PURPOSE OTHER THAN THAT AGREED UPON BETWEEN TOSHIBA AND THE CUSTOMER. THESE SITE PLANS ARE NOT TO BE USED FOR CONSTRUCTION PURPOSES. DATE: 01 -24 -2013 SCALE: NOT TO SCALE PLANNER: G. 0. QUOTE: N/A PROJECT NO. 130013266CTF 2G!N2j ALL INFORMATION ON THIS SHEET IS TO BE CONSIDERED PRELIMINARY AND TENTATIVE AND IS SUBJECT TO CHANGE OR REVISION WITHOUT PRIOR NOTICE. THIS INFORMATION IS FOR PLANNING PURPOSES ONLY. � 6 � CT SCAN ROOM TOILET #1423 1418 CONTROL ROOM j1409 [NOTE. HE EQUIPMENT SHOWN IN THIS YOUT MUST BE VERIFIED WITH HE FINAL PURCHASE ORDER. / 5 2 TOILET #1423 NOTE: MINIMUM SERVICE CLEARANCE REQUIRED ON BOTH SIDES OF GANTRY. PATIENT ENTRY EQUIPMENT LAYOUT U T 2' 4' 0' 16, 5 10 20 2 2 CT SCAN ROOM 418 2 z SCATTER RADIATION FIELD 0 T 2' 4' g' 18' O NOTE: NOT USED IN THIS LAYOUT. STORAGE 410 CONTROL ROOM 409 NOTE: A. THE POWER SOLUTION SHOWN IS FOR PLANNING PURPOSES ONLY. THE FINAL ORDER WILL SHOW THE POWER SOLUTION CONFIGURATION REQUIRED TO MEET SITE SPECIFIC CONDITIONS. SEE ELECTRICAL NOTE "X" ON SHEET GN1 FOR MORE INFORMATION. B. THE 08000 UNINTERRUPTIBLE POWER SUPPLY (UPS) WITH BATTERY CABINET (BAT) SHOWN HERE ARE TO BE REMOTELY LOCATED. C. SEE RECOMMENDED DELIVERY REQUIREMENTS DETAIL 5, SHEET GN2. D. THE REMOTE STATUS ALARM PANEL (RSAP) SHOWN HERE, WILL BE WALL MOUNTED IN THE CONTROL ROOM, E SEE EQUIPMENT SPECIFICATIONS ON SHEET A2. F. THE "UPS" AND "BAY' CABINETS CAN BE SEPARATED. CABLES BETWEEN "UPS" AND "BAT" CAN BE RUN UP TO, BUT NOT TO EXCEED, 70' -0" IN LENGTH. G. THIS EQUIPMENT, IF PURCHASED, WILL BE PROVIDED BY TOSHIBA AND INSTALLED BY CUSTOMER /CONTRACTOR. H. 16" AIR FLOW CLEARANCE ABOVE "UPS" IS REQUIRED. I. "RSAP" MONITOR MUST BE LOCATED WITHIN 1,000 FEET OF THE "UPS ". "RSAP" TO BE INSTALLED BY CUSTOMER'S ELECTRICIAN. CUSTOMER'S ELECTRICIAN MUST PROVIDE 7 TWISTED PAIR 16 AWG CABLE (SIGNAL), AND 18 AWG WIRE (POWER) FROM "UPS" TO "RSAP SCATTER RADIATION UNITS: MICROGRAY (PER 100 THAR) THE AMOUNT OF SCATTERED RADIATION DURING SCANNING IS SHOWN IN THE EQUIPMENT LAYOUT. REFER TO THIS DATA WHEN SCANNING TO MINIMIZE X —RAY EXPOSURE. NOTE THAT THE AMOUNT OF SCATTERED RADIATION DIFFERS DEPENDING ON THE PATIENT; THEREFORE, THE DATA SHOWN SHOULD BE USED ONLY AS A GUIDE. 120kV ) 100mA ( LOs ) M ( 8mm x 4 ( 320mm diameter PMMA phantom. THE ABOVE CALCULATION IS BASED ON A MULTI —SLICE EXPOSURE. THE CUSTOMER /CONTRACTOR IS RESPONSIBLE FOR HAVING SHIELDING CALCULATIONS PREPARED BY A LICENSED RADIATION PHYSICIST. TOSHIBA REPRESENTATIVE WILL PROVIDE THE VERTICAL PLANE SCATTER DIAGRAM UPON REQUEST. REVISED: 01-08-13 04 REC EQUIPMENT LEGEND -10 15/16" 298.00 10' -3 15/16" ^ A' ITEM ELEC. SYM• ITEM DESCRIPTION SUPPLIED AND INSTALLED BY TOSHIBA BTU /HR WEIGHT REF. AREA REQUIRED FOR FULL 8' -0" �1 GANT AQUILION GANTRY * 3,859.00 A2 EXTENSION OF PATIENT PCF1 AQUILION PATIENT COUCH (EXTENDED) * 1,070.00 A�2 SKBG COUCH USING ATTACHMENTS. CPU CENTRAL PROCESSING UNIT 10,246.00 261.00 A2 � 6 � CT SCAN ROOM TOILET #1423 1418 CONTROL ROOM j1409 [NOTE. HE EQUIPMENT SHOWN IN THIS YOUT MUST BE VERIFIED WITH HE FINAL PURCHASE ORDER. / 5 2 TOILET #1423 NOTE: MINIMUM SERVICE CLEARANCE REQUIRED ON BOTH SIDES OF GANTRY. PATIENT ENTRY EQUIPMENT LAYOUT U T 2' 4' 0' 16, 5 10 20 2 2 CT SCAN ROOM 418 2 z SCATTER RADIATION FIELD 0 T 2' 4' g' 18' O NOTE: NOT USED IN THIS LAYOUT. STORAGE 410 CONTROL ROOM 409 NOTE: A. THE POWER SOLUTION SHOWN IS FOR PLANNING PURPOSES ONLY. THE FINAL ORDER WILL SHOW THE POWER SOLUTION CONFIGURATION REQUIRED TO MEET SITE SPECIFIC CONDITIONS. SEE ELECTRICAL NOTE "X" ON SHEET GN1 FOR MORE INFORMATION. B. THE 08000 UNINTERRUPTIBLE POWER SUPPLY (UPS) WITH BATTERY CABINET (BAT) SHOWN HERE ARE TO BE REMOTELY LOCATED. C. SEE RECOMMENDED DELIVERY REQUIREMENTS DETAIL 5, SHEET GN2. D. THE REMOTE STATUS ALARM PANEL (RSAP) SHOWN HERE, WILL BE WALL MOUNTED IN THE CONTROL ROOM, E SEE EQUIPMENT SPECIFICATIONS ON SHEET A2. F. THE "UPS" AND "BAY' CABINETS CAN BE SEPARATED. CABLES BETWEEN "UPS" AND "BAT" CAN BE RUN UP TO, BUT NOT TO EXCEED, 70' -0" IN LENGTH. G. THIS EQUIPMENT, IF PURCHASED, WILL BE PROVIDED BY TOSHIBA AND INSTALLED BY CUSTOMER /CONTRACTOR. H. 16" AIR FLOW CLEARANCE ABOVE "UPS" IS REQUIRED. I. "RSAP" MONITOR MUST BE LOCATED WITHIN 1,000 FEET OF THE "UPS ". "RSAP" TO BE INSTALLED BY CUSTOMER'S ELECTRICIAN. CUSTOMER'S ELECTRICIAN MUST PROVIDE 7 TWISTED PAIR 16 AWG CABLE (SIGNAL), AND 18 AWG WIRE (POWER) FROM "UPS" TO "RSAP SCATTER RADIATION UNITS: MICROGRAY (PER 100 THAR) THE AMOUNT OF SCATTERED RADIATION DURING SCANNING IS SHOWN IN THE EQUIPMENT LAYOUT. REFER TO THIS DATA WHEN SCANNING TO MINIMIZE X —RAY EXPOSURE. NOTE THAT THE AMOUNT OF SCATTERED RADIATION DIFFERS DEPENDING ON THE PATIENT; THEREFORE, THE DATA SHOWN SHOULD BE USED ONLY AS A GUIDE. 120kV ) 100mA ( LOs ) M ( 8mm x 4 ( 320mm diameter PMMA phantom. THE ABOVE CALCULATION IS BASED ON A MULTI —SLICE EXPOSURE. THE CUSTOMER /CONTRACTOR IS RESPONSIBLE FOR HAVING SHIELDING CALCULATIONS PREPARED BY A LICENSED RADIATION PHYSICIST. TOSHIBA REPRESENTATIVE WILL PROVIDE THE VERTICAL PLANE SCATTER DIAGRAM UPON REQUEST. REVISED: 01-08-13 04 REC 21' -10 15/16" 298.00 10' -3 15/16" p c Z NOTE 50 NOTE: CONTROL MONITOR 192.00 AREA REQUIRED FOR FULL 8' -0" c cn 10' SCANNING O7 8' 2 1/16„ SPEAKER (DESKTOP) SPEAKER (WALL MOUNT) EXTENSION OF PATIENT A2 n2 C SHELF /COUNTER PROVIDED �8 SKBG COUCH USING ATTACHMENTS. o G BY CUSTOMER /CONTRACTOR. DESK DESK FOR MONITORS & KEYBOARDS 00.00 221.00 e A2 ANY PURPOSE OTHER THAN THAT AGREED UPON BETWEEN TOSHIBA AND THE CUSTOMER. THESE SITE w 10 CHR CHAIR 00.00 55.00 BTU /HR z H z o DATE: 01 -24 -2013 Z 4 II IN NERVISION WORKSTATION L 16.70 n2 15 i ___ lrl�� C P 00.00 38.00 US o w I I STORAGE W 3 #1410 H 1 I F 7 W 00.00 8.20 ISO m H O � o 0 F LL1 13 14 F- � � 6 � CT SCAN ROOM TOILET #1423 1418 CONTROL ROOM j1409 [NOTE. HE EQUIPMENT SHOWN IN THIS YOUT MUST BE VERIFIED WITH HE FINAL PURCHASE ORDER. / 5 2 TOILET #1423 NOTE: MINIMUM SERVICE CLEARANCE REQUIRED ON BOTH SIDES OF GANTRY. PATIENT ENTRY EQUIPMENT LAYOUT U T 2' 4' 0' 16, 5 10 20 2 2 CT SCAN ROOM 418 2 z SCATTER RADIATION FIELD 0 T 2' 4' g' 18' O NOTE: NOT USED IN THIS LAYOUT. STORAGE 410 CONTROL ROOM 409 NOTE: A. THE POWER SOLUTION SHOWN IS FOR PLANNING PURPOSES ONLY. THE FINAL ORDER WILL SHOW THE POWER SOLUTION CONFIGURATION REQUIRED TO MEET SITE SPECIFIC CONDITIONS. SEE ELECTRICAL NOTE "X" ON SHEET GN1 FOR MORE INFORMATION. B. THE 08000 UNINTERRUPTIBLE POWER SUPPLY (UPS) WITH BATTERY CABINET (BAT) SHOWN HERE ARE TO BE REMOTELY LOCATED. C. SEE RECOMMENDED DELIVERY REQUIREMENTS DETAIL 5, SHEET GN2. D. THE REMOTE STATUS ALARM PANEL (RSAP) SHOWN HERE, WILL BE WALL MOUNTED IN THE CONTROL ROOM, E SEE EQUIPMENT SPECIFICATIONS ON SHEET A2. F. THE "UPS" AND "BAY' CABINETS CAN BE SEPARATED. CABLES BETWEEN "UPS" AND "BAT" CAN BE RUN UP TO, BUT NOT TO EXCEED, 70' -0" IN LENGTH. G. THIS EQUIPMENT, IF PURCHASED, WILL BE PROVIDED BY TOSHIBA AND INSTALLED BY CUSTOMER /CONTRACTOR. H. 16" AIR FLOW CLEARANCE ABOVE "UPS" IS REQUIRED. I. "RSAP" MONITOR MUST BE LOCATED WITHIN 1,000 FEET OF THE "UPS ". "RSAP" TO BE INSTALLED BY CUSTOMER'S ELECTRICIAN. CUSTOMER'S ELECTRICIAN MUST PROVIDE 7 TWISTED PAIR 16 AWG CABLE (SIGNAL), AND 18 AWG WIRE (POWER) FROM "UPS" TO "RSAP SCATTER RADIATION UNITS: MICROGRAY (PER 100 THAR) THE AMOUNT OF SCATTERED RADIATION DURING SCANNING IS SHOWN IN THE EQUIPMENT LAYOUT. REFER TO THIS DATA WHEN SCANNING TO MINIMIZE X —RAY EXPOSURE. NOTE THAT THE AMOUNT OF SCATTERED RADIATION DIFFERS DEPENDING ON THE PATIENT; THEREFORE, THE DATA SHOWN SHOULD BE USED ONLY AS A GUIDE. 120kV ) 100mA ( LOs ) M ( 8mm x 4 ( 320mm diameter PMMA phantom. THE ABOVE CALCULATION IS BASED ON A MULTI —SLICE EXPOSURE. THE CUSTOMER /CONTRACTOR IS RESPONSIBLE FOR HAVING SHIELDING CALCULATIONS PREPARED BY A LICENSED RADIATION PHYSICIST. TOSHIBA REPRESENTATIVE WILL PROVIDE THE VERTICAL PLANE SCATTER DIAGRAM UPON REQUEST. REVISED: 01-08-13 ITEM ELEC. OPTIONAL ITEM DESCRIPTION - SYM. SUPPLIED & INSTALLED BY TOSHIBA 12 INJP MEDRAD INJECTOR (PEDESTAL MOUNTED) 13 INJC MEDRAD INJECTOR BASE UNIT 14 INJR MEDRAD INJECTOR DISPLAY CONTROL UNIT W /STAND a 04 REC RECONSTRUCTION UNIT (BTU /HR INCLUDED WITH "CPU ") - -. -- 298.00 3 A2 p c Z EXAM ROOM 50 MAN CONTROL MONITOR 192.00 17.60 a A2 c cn O SCANNING O7 SEP1 SPK2 SPEAKER (DESKTOP) SPEAKER (WALL MOUNT) 00.00 00.00 4.41 4.41 A2 n2 C 0 �8 SKBG KEYBOARD (SCAN) 00.00 5.95 G DESK DESK FOR MONITORS & KEYBOARDS 00.00 221.00 e A2 ANY PURPOSE OTHER THAN THAT AGREED UPON BETWEEN TOSHIBA AND THE CUSTOMER. THESE SITE w 10 CHR CHAIR 00.00 55.00 BTU /HR z H z o DATE: 01 -24 -2013 Z 11 INV IN NERVISION WORKSTATION L 16.70 n2 C P 00.00 38.00 US ITEM ELEC. OPTIONAL ITEM DESCRIPTION - SYM. SUPPLIED & INSTALLED BY TOSHIBA 12 INJP MEDRAD INJECTOR (PEDESTAL MOUNTED) 13 INJC MEDRAD INJECTOR BASE UNIT 14 INJR MEDRAD INJECTOR DISPLAY CONTROL UNIT W /STAND a ITEM ELEC. OPTIONAL ITEM DESCRIPTION - SUPPLIED BY TOSHIBA BTU /HR WEIGHT REF. SYM. &INSTALLED BY CUSTOMER /CONTRACTOR 15 PD POWER DISTRIBUTOR 2,730.00 1,197.00 a A2 ' ITEM I SYM. I SUPPLIED AND INSTALLEDIBY CUSTOMER I CONTRACTOR I BTU /HR I WEIGHT I REF. I GANTRY $ COUCH BTU / HOUR: IN ORDER TO USE THIS SET OF FINAL SITE PLANS, A CUSTOMER SIGNATURE IS REQUIRED o N C Z EXAM ROOM SCANNING 4 PATIENTS: 22,128.00 BTU /HR DATE: SALES: O SCANNING 5 PATIENTS: 23,151.00 BTU THESE TOSHIBA PLANS ARE FOR 0 INFORMATIONAL PURPOSES ONLY AND SHALL NOT BE USED FOR FUTURE GROWTH OF FACILITY FORECASTING PATIENT MUST NUMBERS FOR BE CONSIDERED WHEN A/C REQUIREMENTS. ANY PURPOSE OTHER THAN THAT AGREED UPON BETWEEN TOSHIBA AND THE CUSTOMER. THESE SITE w REVISED: 01 -08 -13 PLANS ARE NOT TO BE USED FOR CONSTRUCTION PURPOSES. BTU /HR WEIGHT REF. z o DATE: 01 -24 -2013 Z w C P 00.00 38.00 w o W 320.00 13.60 H W F 00.00 8.20 m H O ITEM ELEC. OPTIONAL ITEM DESCRIPTION - SUPPLIED BY TOSHIBA BTU /HR WEIGHT REF. SYM. &INSTALLED BY CUSTOMER /CONTRACTOR 15 PD POWER DISTRIBUTOR 2,730.00 1,197.00 a A2 ' ITEM I SYM. I SUPPLIED AND INSTALLEDIBY CUSTOMER I CONTRACTOR I BTU /HR I WEIGHT I REF. I * AQUILION GANTRY $ COUCH BTU / HOUR: IN ORDER TO USE THIS SET OF FINAL SITE PLANS, A CUSTOMER SIGNATURE IS REQUIRED o N C Z EXAM ROOM SCANNING 4 PATIENTS: 22,128.00 BTU /HR DATE: SALES: O SCANNING 5 PATIENTS: 23,151.00 BTU THESE TOSHIBA PLANS ARE FOR 0 INFORMATIONAL PURPOSES ONLY AND SHALL NOT BE USED FOR FUTURE GROWTH OF FACILITY FORECASTING PATIENT MUST NUMBERS FOR BE CONSIDERED WHEN A/C REQUIREMENTS. ANY PURPOSE OTHER THAN THAT AGREED UPON BETWEEN TOSHIBA AND THE CUSTOMER. THESE SITE w REVISED: 01 -08 -13 PLANS ARE NOT TO BE USED FOR CONSTRUCTION PURPOSES. Ca a DATE: 01 -24 -2013 LL w W H W m � o 0 F LL1 F- � O J Q - ) (D) Z 00 0L °0) Z W a z0 > m < O W Dv V 53 J � Q :>- W < d Q � W W nop * AQUILION GANTRY $ COUCH BTU / HOUR: IN ORDER TO USE THIS SET OF FINAL SITE PLANS, A CUSTOMER SIGNATURE IS REQUIRED o N C EXAM ROOM SCANNING 2 PATIENTS: 20,081.00 BTU /HR EXAM ROOM SCANNING 3 PATIENTS: 21,104.00 BTU /HR EXAM ROOM SCANNING 4 PATIENTS: 22,128.00 BTU /HR DATE: SALES: EXAM ROOM SCANNING 5 PATIENTS: 23,151.00 BTU THESE TOSHIBA PLANS ARE FOR ROOM SCANNING MAXIMUM: 24,175.00 BTU /HR INFORMATIONAL PURPOSES ONLY AND SHALL NOT BE USED FOR FUTURE GROWTH OF FACILITY FORECASTING PATIENT MUST NUMBERS FOR BE CONSIDERED WHEN A/C REQUIREMENTS. ANY PURPOSE OTHER THAN THAT AGREED UPON BETWEEN TOSHIBA AND THE CUSTOMER. THESE SITE REVISED: 01 -08 -13 PLANS ARE NOT TO BE USED FOR CONSTRUCTION PURPOSES. DATE: 01 -24 -2013 SCALE: 1/4" = 1' -0" PLANNER: G.O. QUOTE N/A PROJECT NO. 130013266CTF Al SITE PLAN APPROVAL IN ORDER TO USE THIS SET OF FINAL SITE PLANS, A CUSTOMER SIGNATURE IS REQUIRED BELOW, THE CUSTOMER'S SIGNATURE DEMONSTRATES ACCEPTANCE OF THE LAYOUT SHOWN AND ALIL STATED SPECIFICATIONS. CUSTOMER: DATE: SALES: DATE: I.P.M.: DATE: SCALE: 1/4" = 1' -0" PLANNER: G.O. QUOTE N/A PROJECT NO. 130013266CTF Al ALL INFORMATION ON THIS SHEET IS TO BE CONSIDERED PRELIMINARY AND TENTATIVE AND IS SUBJECT TO CHANGE OR REVISION WITHOUT PRIOR NOTICE. THIS INFORMATION IS FOR PLANNING PURPOSES ONLY. - -- W. 15 11/16" 17 11/16" C c PLAN PLAN _ —_— r\i PLAN 8„ ---- -__ - -- - O •� �I �U 2' -8 1/16" 2' -8 1/16' , W J o � 13 11/16° 14 3/4" rn m 3' -0 1/2" 10' -1 1/4" z iv N 5 -6 1/4" FRONT SIDE FRONT SIDE FRONT SIDE PLAN CENTRAL 16' -4 1/16" O PROCESSING UNIT O RECONSTRUCTION UNIT O CONTROL MONITOR(S) SCALE: 112" = 1' -0" 01 -08 -13 SCALE: 1/2" = 1' -0" 01 -08 -13 SCALE: 1 1/2" = 1' -0" . 01 -08 -10 J _ _-- - - - - - Z 12 -0 1 /8 " GANT ------- ' -, - - -- -- PCN UPS CPU SPK7 - N REC MON 5'-5" 3' -1 13/16° 8' -9 7/8" HEAT OUTPUT (BTU'S) HEAT OUTPUT (BTU'S) HEAT OUTPUT (BTU'S) HEAT OUTPUT (BTU'S) HEAT OUTPUT (BTU'S) SEE SHEET Al SEE SHEET Al 10,246.00 INCLUDED W / "CPU" 192.00 HEAT OUTPUT (BTU'S) 00.00 WEIGHT LIES WEIGHT (LBS) WEIGHT (LBS) WEIGHT (LBS) WEIGHT LBS) 3,859.00 1,070.00 261.00 298.00 1 7.60 - -- W. 15 11/16" 17 11/16" C c PLAN PLAN _ —_— r\i PLAN 8„ ---- -__ - -- - O •� �I �U 2' -8 1/16" 2' -8 1/16' , W J o � 13 11/16° 14 3/4" rn m 3' -0 1/2" 10' -1 1/4" z iv N 5 -6 1/4" FRONT SIDE FRONT SIDE FRONT SIDE PLAN CENTRAL 16' -4 1/16" O PROCESSING UNIT O RECONSTRUCTION UNIT O CONTROL MONITOR(S) SCALE: 112" = 1' -0" 01 -08 -13 SCALE: 1/2" = 1' -0" 01 -08 -13 SCALE: 1 1/2" = 1' -0" . 01 -08 -10 J _ _-- - - - - - Z N \ \111 1 1 11 1 1 I I 1 1 1 1 1 1 1 1 1 -' 3' PD ------- ' -, - - -- -- UPS 1 1/2" _ SPK7 - N 5 1 /2° DESK 5'-5" INV (CPU) Q J LIJ �-- HEAT OUTPUT (BTU'S) HEAT OUTPUT (BTU'S], HEAT OUTPUT (BTU'S) HEAT OUTPUT (BTU'S) 2,730.00 7,816,00 -.- HEAT OUTPUT (BTU'S) 00.00 -__� _•,, ,. 4 WEIGHT tv 1,197.00 2,31 6.00 10.00 3,548.00 .41LBS) PLAN v HEAT OUTPUT (BTU'S) HEAT OUTPUT (BTU'S) HEAT OUTPUT (BTU'S) w ° 00.00 00.00 - - WEIGHT LBS) WEIGHT WEIGHT 41 6.70LBS) N \ \111 1 1 11 1 1 I I 1 1 1 1 1 1 1 1 1 -' 3' PD �� UPS 1 1/2" _ a - N 5 1 /2° BAT 5'-5" W Q J LIJ �-- HEAT OUTPUT (BTU'S) HEAT OUTPUT (BTU'S], HEAT OUTPUT (BTU'S) HEAT OUTPUT (BTU'S) 2,730.00 7,816,00 -.- HEAT OUTPUT (BTU'S) 00.00 -__� _•,, ,. 4 WEIGHT tv 1,197.00 2,31 6.00 10.00 3,548.00 .41LBS) PLAN PLAN ° - - - -._ PLAN /JL L > 3' -11 15/16' 5 5/16" 3 0 14 7/8" a' (MAX. HEADREST EXT.) 22 13/16" 14 15/16" 7'- 73/4" 4' -3 15/16" 11 (MAX ARM -UP EXT.) 3' -1 13/16" 5' -3 15/16" (RECOMMENDED DISTANCE TO WALL) N O 17' -4 1/16" LLI J Q J 0) SIDE Ln FRONT FRONT SIDE FRONT SIDE FRONT SIDE W � a OAQUILION CT SCANNER - GANTRY AND PATIENT COUCH (EXTENDED) O SPEAKER(S) O CONTROL DESK O INNERVISION W Q z0 m � SCALE: 1/2" = 1' -0" 01 -OS -13 SCALE: 1 1/2" = 1' -0" 01 -OS -13 SCALE: 1/2" = 1' -0" 01 -08 -13 SCALE: 1" = 1' -0" 01 -08 -13 J Q 5 :7) 5 3' -0 13/16" 2' -8 1/2" M 3' 0„ 2' THESE TOSHIBA PLANS ARE FOR INFORMATIONAL `� PLAN FORMAT1oNAL PURPOSES ONLY Z' -il 7/16" AND SHALL NOT BE USED FOR PLAN 6 1 0 AGREED RUPON BETWEENHTOSH�IBA PLAN AND THE CUSTOMER. THESE SITE PLANS ARE NOT TO BE USED 2 FOR CONSTRUCTION PURPOSES. _ _ DATE: 01 -24 -2013 ° + + a \ \ SCALE: AS NOTED o 9 ET o PLANNER: G.O. m �° N EE i� ❑ QUOTE: N/A 1 /2 PROJECT NO. FRONT SIDE FRONT SIDE FRONT SIDE FRONT SIDE 130013266CTF G8000 UNINTERRUPTIBLE REMOTE 8 POWER DISTRIBUTOR C9) POWER SUPPLY 7 � STATUS ALARM PANEL BATTERY CABINET A2 SCALE: 1/2" = 1' -0" 01 -08 -13 SCALE: 1/2" = 1' -0" 01 -08 =13 SCALE: 2" = 1' -0" 01 -08 -13 SCALE: 1/2" = 1' -0" 01 -08 -13 . H W 0) O CL d 3' PD UPS 1 1/2" _ - N RSAP BAT W Q J LIJ �-- HEAT OUTPUT (BTU'S) HEAT OUTPUT (BTU'S], HEAT OUTPUT (BTU'S) HEAT OUTPUT (BTU'S) 2,730.00 7,816,00 -.- 1 ,000.00 WEIGHT (LBS) WEIGHT (LBS) WEIGHT (LBS) WEIGHT (LBS) 1,197.00 2,31 6.00 10.00 3,548.00 3' -0 13/16" 2' -8 1/2" M 3' 0„ 2' THESE TOSHIBA PLANS ARE FOR INFORMATIONAL `� PLAN FORMAT1oNAL PURPOSES ONLY Z' -il 7/16" AND SHALL NOT BE USED FOR PLAN 6 1 0 AGREED RUPON BETWEENHTOSH�IBA PLAN AND THE CUSTOMER. THESE SITE PLANS ARE NOT TO BE USED 2 FOR CONSTRUCTION PURPOSES. _ _ DATE: 01 -24 -2013 ° + + a \ \ SCALE: AS NOTED o 9 ET o PLANNER: G.O. m �° N EE i� ❑ QUOTE: N/A 1 /2 PROJECT NO. FRONT SIDE FRONT SIDE FRONT SIDE FRONT SIDE 130013266CTF G8000 UNINTERRUPTIBLE REMOTE 8 POWER DISTRIBUTOR C9) POWER SUPPLY 7 � STATUS ALARM PANEL BATTERY CABINET A2 SCALE: 1/2" = 1' -0" 01 -08 -13 SCALE: 1/2" = 1' -0" 01 -08 =13 SCALE: 2" = 1' -0" 01 -08 -13 SCALE: 1/2" = 1' -0" 01 -08 -13 . H W 0) O CL d ALL INFORMATION ON THIS SHEET IS TO BE CONSIDERED PRELIMINARY AND TENTATIVE AND IS SUBJECT TO CHANGE OR REVISION WITHOUT PRIOR NOTICE. THIS INFORMATION IS FOR PLANNING PURPOSES ONLY. H W H O IL IL Z O r V M H H Z O 0 ce O LL G W N m W m O H H O Z t J O W u Z W 19 W LL W 19 19 O L6 ALL INFORMATION ON THIS SHEET IS TO BE CONSIDERED PRELIMINARY AND TENTATIVE AND IS SUBJECT TO CHANGE OR REVISION WITHOUT PRIOR NOTICE. THIS INFORMATION IS FOR PLANNING PURPOSES ONLY. ALL INFORMATION ON THIS SHEET IS TO BE CONSIDERED PRELIMINARY own TFNTATwIP Awn is ciin ier%T rn #%UALIr -10 .,e DL'..IC-%I.,./ %AII9F JA //T ..NMNN0%., .....-0-00.� NONE .... OWN .......___.__.... vi W H O Z O H V OC H H Z O v lz O LIN G W W m w m 0 H D Z J D L J Z L u L u r 6 ALL INFORMATION ON THIS SHEET IS TO BE CONSIDERED PRELIMINARY AND TENTATIVE AND IS SUBJECT TO CHANGE OR REVISION WITHOUT PRIOR NOTICE. THIS INFORMATION IS FOR PLANNING PURPOSES ONLY. POWER QUALITY REQUIREMENTS AQUILION - SUPPLY CONFIGURATION:' -3 PHASE, 3 WIRE POWER, AND GROUND, DELTA OR WYE (SEE NOTE A) NOMINAL LINE VOLTAGE: 480 VAC, 60 HZ (SEE NOTE B) LINE VOLTAGE VARIATION: ±10% STEADY-STATE INCLUDING SAGS AND SURGES LINE VOLTAGE BALANCE: 2% MAXIMUM OF NOMINAL VOLTAGE BETWEEN PHASES. FREQUENCY VARIATION: -' f1 HZ HARMONIC DISTORTION 3% STEADY -STATE 5% FOR SHORT PERIODS (1 MINUTE OR LESS) GROUND CONDUCTOR IMPEDANCE 0.1 OHMS ® 60 HZ, TO NEUTRAL - GROUND BONDING POINT (SEE NOTE D) S 150 KVA STANDARD TRANSFORMER CAPACITY MAXIMUM SYSTEM DEMAND 100 BOA (IMAGING) CONDUCTOR SIZES (SEE NOTE E) FOR 1.5% IMPEDANCE OF BRANCH CONDUCTORS (20 -C) CONDUCTOR SIZE '- LENGTH BREAKER FRAME SIZE #2 AWG 1218 FT 1200 A #1 AWG 303 FT 377 FT X200 A 200 A 200 A 1/0 AWG 2/0 AWG 444 FT. CIRCUIT BREAKER SIZE: 100 A (SEE NOTE F) MOMENTARY MAXIMUM CURRENT: 150 A MAXIMUM VOLTAGE DROP. __.% 24 O V REGULATION: 5.0% * REFER TO DETAIL 1, SHEET E3 FOR CONDUCTOR SIZE USING COMBINED _ NSIDE CT ROOM LENGTHS OF RUNS 'k" & "Y ". C I F POSSIBLE) CUSTOMER SUPPLIED TOSHIBA SUPPLIED ADDITIONAL "EPO" SWITCHES TO BE m iv LOCATED BY CUSTOMER /CONTRACTOR ' IF NEEDED. O EMERGENCY L- POWER OFF SHUNT TRIP PUSH BUTTON IN "X -RAY ON" WARNING °EPO" CONTROL AREA W/ A NORMALLY LIGHT MOUNTED ABOVE PUSH BUTTON OPEN CONTACT (IF REQUIRED). SCAN ROOM DOOR. WALL (DPDT) WIRES PER CODE TO I SHUNT TRIP PUSH BUTTON. FLEX CONDUIT FROM O •. WALL DUCT /J -BOX ma SUPPLIED AND NEUTRAL "X -RAY ON" OR TO CONNECT TO "PD ". SER INSTALLED BY WARNING LIGHT ON PER MAIN VICE jEX ^+ SHUNT TRIP 'Y "* PD TOSHIBA TOSHIBA X -RAY SIGNAL. ENTRANCE PANEL CIRCUIT BREAKER � (SEE NOTE 1) 120V 2' WALL DUCT J _ 10" W X 10 " H X 4" D J -BOX, _ FLUSH MOUNTED IN FINISHED I"CANT" w_OCATED F SWITCH WITH O WALL. OPEN TO WALL DUCT. z 40 AMP NEAR 48OV, 3 POLE �-� I G I G 50 AMP - - - � l , 48OV, 100 AMP w a > Z GROUND SOURCE GROUND ELECTRODE PER NEC 250 -30(A) d PER BUILDING STEEL, WATER PIPE, OR GROUNDING ELECTRODE AS w U V) N 50 CLOSE AS PHYSICALLY POSSIBLE TO THE "PD ". GROUND o CONDUCTORS MUST BE SAME SIZE AS PHASE CONDUCTORS, NOTE 1 NOTE: TOSHIBA SUPPLIED POWER CABLES BETWEEN THE "PD" AND TOSHIBA EQUIPMENT A. "X -RAY ON" OR WARNING LIGHT TO BE ARE TO BE USEE3 IF THE CABLE LENGTHS PROVIDED ARE SUFFICIENT. IN CASES PROVIDED BY CUSTOMER /CONTRACTOR. WHERE EXTENDE[7 CABLE LENGTHS ARE REQUIRED, THE CUSTOMER /CONTRACTOR B. USE INCANDESCENT FIXTURES ONLY. _ MUST PROVIDE CABLES PER LOCAL /NATIONAL CODES. NOTE* SUGGESTED MOUNTING OF J -BOX FOR "PD" OR AS PER LOCAL CODE. w 2 "CB" / N %PD" WIRING DETAIL O WARNING LIGHT DETAIL I(DSCALE: TYPICAL "PD" J -BOX MOUNTING STANDARD POWER QUALITY NOTES SCALE: NOT T(C SCALE 01 -OS -13 SCALE: NOT TO SCALE 01 -08 -13 1/2" = 1' -O" 01 -08 -13 A. A GROUNDED NEUTRAL POWER SOURCE IS REQUIRED TO ASSURE RELIABLE EQUIPMENT OPERATION. THE NEUTRAL CONDUCTOR MAY NOT BE USED FOR A PARTICULAR SYSTEM. B. IN CASES WHERE MULTIPLE VOLTAGES ARE PERMITTED, THE PREFERRED SYSTEM VOLTAGE IS SPECIFIED. C. DUE TO THE HIGH INSTANTANEOUS POWER OF MEDICAL IMAGING SYSTEMS, USE THE HIGHEST AVAILABLE VOLTAGE SOURCE. ENSURE THAT LOWER VOLTAGE SOURCES ARE DERIVED DIRECTLY FROM THE SERVICE ENTRANCE OF THE FACILITY. D. GROUND CONDUCTORS ARE REQUIRED TO BE THE SAME SIZE AS THE PHASE CONDUCTORS C \ W UNLESS A LARGER SIZE IS REQUIRED BY CODE. G J Q E. ALL FEEDER AND BRANCH CIRCUIT CONDUCTORS MUST BE COPPER - ALUMINUM IS NOT NOTE: W x (/) T) NOTE CUSTOMER'S CONTRACTOR TO VERIFY LOCATION PERMITTED. � � � SPLIT ACCESS OPENING OR OF J- BOX(ES) FOR CABLE PULL TO WALL DUCT. F. IF THE EQUIPMENT CIRCUIT BREAKER IS NOT LOCATED IN THE CONTROL AREA, A SHUNT SPLIT ACCESS COVER ON CUSTOMER'S CONTRACTOR TO VERIFY LOCATION W J OF TRIP BREAKER MUST BE USED IN ORDER TO COMPLY WITH N.E.C. 517- 72(B). A FACE OF WALL DUCT. OF GROMMETED OPENINGS IN WALL DUCT WITH V d PUSH - BUTTON TO OPERATE THE SHUNT TRIP MUST BE LOCATED IN THE CONTROL AREA. TOSHIBA REP. -Z J J NOTE: z Q G. A SEPARATE CIRCUIT, FED FROM THE FACILITY RADIOLOGY PANEL OR A MAIN SERVICE PANEL 45 SECTION SURFACE MOUNTED WALL iii Q O m IS REQUIRED. USE OF A SUB PANEL WITH LOADS SUCH AS ELEVATORS, HVAC, MOTORS, FOR ALL WALL DUCT W /(3) EQUALLY ETC., IS NOT PERMITTED. DUCT CORNERS. DIVIDED PARTITIONS Q THROUGHOUT W/ PARTITION H. DEVICES SUCH AS UNINTERRUPTIBLE POWER SUPPLIES, POWER CONDITIONERS, VOLTAGE CUT -OUTS AT OPENINGS. O W 5 O J REGULATORS, AND FILTERS MAY BE INCOMPATIBLE WITH THIS IMAGING EQUIPMENT. CONSULT YOUR TOSHIBA SERVICE REPRESENTATIVE PRIOR TO PURCHASING OR INSTALLING THESE Q Z W DEVICES. � Q I. THE MAINS POWER GROUND CONDUCTOR IS TO BE RUN WITH THE POWER PHASE NOTE: CONDUCTORS. THE GROUNDS TO BUILDING STEEL OR EARTH GROUND ARE NOT TO BE RUN FLUSH MOUNTED J -BOX WITH THE PHASE CONDUCTORS. (OPEN TO WALL DUCT) CD N SYSTEM DAMAGE MAY OCCUR 200% ABOVE (DISRUPTIVE IMPULSES) NOMINAL VOLTAGE FINISHED FLOOD THESE TOSHIBA PLANS ARE FOR REMOVABLE COVER. INFORMATIONAL PURPOSES ONLY SYSTEM DISRUPTION AND SHALL NOT BE USED FOR MAY OCCUR ANY PURPOSE OTHER THAN THAT 100% ABOVE (DISRUPTIVE IMPULSES) SYSTEM DAMAGE MAY OCCUR AGREED UPON BETWEEN TOSHIBA AND THE CUSTOMER. THESE SITE NOMINAL VOLTAGE (HIGH VOLTAGE, SWELLS, & SURGES) PLANS ARE NOT To BE USED FOR CONSTRUCTION PURPOSES. DATE: 01 -24 -2013 +10% ABOVE NOMINAL SCALE: NOT TO SCALE NOMINAL VOLTAGE - - - - -- - - - - -- -- - - - - -- - - - -- -- - - - - -- - - - - -- FQ EQ 10" TRENCH DUCT: A = 10" -10% BELOW NOMINAL EQ. B = 12" PLANNER: G.O. h = 16" TRENCH DUCT A = 16" ACCEPTABLE VOLTAGE RANGE SYSTEM DISRUPTION MAY OCCUR A B = 18 (LOW VOLTAGE, SAGS, & OUTAGE) 18" TRENCH DUCT. A = 18" QUOTE: N/A 6 B - 20„ R 24" TRENCH DUCT: A = 24" PROJECT NO. B = 26" 30" TRENCH DUCT: A = 30" 130013266CTF 10 MS 100 pS 1 ms 10 mS 100 ms 1 Sec 1 Min i Hr B = 32" L TYPICAL DUCT DETAIL WITH WALL DUCT E3 POWER REQUIREMENTS WITH PCDU O TRENCH DUCT / J -BOX / VERTICAL RISER SCALE: NOT TO SCALE 01 -08-13 SCALE: NOT TQ SCALE 01 -08 -13 ALL INFORMATION ON THIS SHEET IS TO BE CONSIDERED PRELIMINARY AND TENTATIVE AND IS SUBJECT TO CHANGE OR REVISION WITHOUT PRIOR NOTICE. THIS INFORMATION IS FOR PLANNING PURPOSES ONLY.