3102-3 Heating Simple Heating System Size: Washington State This heating system sizing calculator is based on the Prescriptive Requirements of the 2012 Washington State Enerqv Code(WSEC)and ACCA Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling loads. The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC. Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section,some values will be calculated for you.If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension Program at (360)956-2042 for assistance. Project Information Contact Information PLAN#3102-3 LOT29 RiPPEL EVE;GFEEN STATE BU I LDERS JIHVSSV DR cE J57 KELLY YELM,WA 98439 253-255-1616 Heating System Type: O All other systems O Heat Pump To see detailed instructions for each section,place your cursor on the word'Instructions". Design Temperature Instructions Design Temperature Difference(4T) 53 Tumwater AT=Indoor(70 degrees)-Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area(sq ft) 3,090 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height(ft) 8.5 26,265 Glazing and Doors U-Factor X Area = UA Instructions 0.30 450 135.00 Skylights U-Factor X Area = UA Instructions 0.50 Insulation Attic U-Factor X Area = UA Instructic,_ j R-49 0.026 1,314 34.16 L � Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions j l No Vaulted Ceilings in this project. � Above Grade Walls(see Figure 1) U-Factor X Area UA Instructions 0.056 3,373 188.89 R-21 Intermediate � Floors U-Factor X Area UA Instructions j R-30 0.029 3,090 89.61 L � Below Grade Walls(see Figure 1) U-Factor X Area UA Instructions No --- --- l Below Grade Walls in this project. � Slab Below Grade(see Figure 1) F-Factor X Length UA Instructions No Slab Below Grade in this project. � --- Slab on Grade(see Figure 1) F-Factor X Length UA Instructions No Slab on Grade in this project. � Location of Ducts Instructions Duct Leakage Coefficient Conditioned Space 1.00 Sum of UA 447.66 Envelope Heat Load 23,726 Btu/Hour Figure 1. Sum ofuAxAT Air Leakage Heat Load 15,034 Btu/Hour VolumeX 0.6XATX.018 Above Qade Building Design Heat Load 38,760 Btu/Hour Air Leakage+Envelope Heat Loss Building and Duct Heat Load 38,760 Btu/Hour Ducts in unconditioned space:Sum of Building Heat Loss X 1.10 Ducts in conditioned space:Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 54,264 Btu/Hour Building and Duct Heat Loss X 1.40 for Forced Air Furnace Building and Duct Heat Loss X 1.25 for Heat Pump (07/01/13)