Loading...
3153-3 Heating Simple Heating System Size: Washington State This heating system sizing calculator is based on the Prescriptive Requirements of the 2012 Washington State Enerqv Code(WSEC)and ACCA Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling loads. The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC. Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section,some values will be calculated for you.If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension Program at (360)956-2042 for assistance. Project Information Contact Information PUV\1#31533 EVE;GFEEN SPATE BUILDERS ,64SEV DR EE iggaLy YBM,WA 98439 253255-1616 Heating System Type: O All other systems O Heat Pump To see detailed instructions for each section,place your cursor on the word'Instructions". Design Temperature Instructions Design Temperature Difference(4T) 53 Tumwater AT=Indoor(70 degrees)-Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area(sq ft) 3,153 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height(ft) 8.5 26,801 Glazing and Doors U-Factor X Area = UA Instructions 0.30 398 119.40 Skylights U-Factor X Area = UA Instructions 0.50 Insulation Attic U-Factor X Area = UA Instructic,_ j R-49 0.026 1,344 34.94 L � Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions j l No Vaulted Ceilings in this project. � Above Grade Walls(see Figure 1) U-Factor X Area UA Instructions 0.056 3,295 184.52 R-21 Intermediate � Floors U-Factor X Area UA Instructions j R-30 0.029 3,153 91.44 L � Below Grade Walls(see Figure 1) U-Factor X Area UA Instructions No --- --- l Below Grade Walls in this project. � Slab Below Grade(see Figure 1) F-Factor X Length UA Instructions No Slab Below Grade in this project. � --- Slab on Grade(see Figure 1) F-Factor X Length UA Instructions No Slab on Grade in this project. � Location of Ducts Instructions Duct Leakage Coefficient Conditioned Space 1.00 Sum of UA 430.30 Envelope Heat Load 22,806 Btu/Hour Figure 1. Sum ofuAxAT Air Leakage Heat Load 15,341 Btu/Hour VolumeX 0.6XATX.018 Above Qade Building Design Heat Load 38,147 Btu/Hour Air Leakage+Envelope Heat Loss Building and Duct Heat Load 38,147 Btu/Hour Ducts in unconditioned space:Sum of Building Heat Loss X 1.10 Ducts in conditioned space:Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 53,405 Btu/Hour Building and Duct Heat Loss X 1.40 for Forced Air Furnace Building and Duct Heat Loss X 1.25 for Heat Pump (07/01/13)