Loading...
20130369 Permit Pkg 12242013 ',,��oF rH�P,� City of Yelm Permit No.: 20130369 � a � Community Development Department Issue Date: 12/24/2013 (Work must be completed within 180 days) Building Division Phone: (360)458-8407 LM `"`""'"4�4" Fax: (360)458-3144 Applicant: Name: JAMES PHILLIPS Phone: 360-458-0503 Address: 15621 92ND WAY SE YELM WA 98597 Property Information: site Address: 15621 92ND WAY SE Owner: JAMES PHILLIPS Assessor Parcel No.: 55360001300 Subdivision: Lot: Contractor Information: Name: WESCO Phone: 206-378-2033 Address: 2800 THORNDYKE AVENUE WEST SEATTLE WA 98199 Contractor License No.: WASHIES97106000 Expires: 9/28/2011 Project Information: Project: MECHANICAL Description of Work: REPLACE 60K GAS FURNACE Sq. Ft. per floor: First Heat Type(Electric, Gas, Other): Second Third Garage Basement Fees: Item Contractor Fees MECHANICAL WESCO $ 29.50 TOTAL FEES: $ 29.50 ApplicanYs Affidavit: OFFICIAL USE ONLY I certify that I have read and examined the information contained within the application and know the same to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of #Sets of Prints: Yelm regulations including those governing zoning and land subdivision,and in addition,all covenants, easements and restrictions of record. If applying as a contractor,I further certify that I am currently Final Inspection: registered in the State of Washin�gton. �.��. , ' `�+ ' a � ' ' �,�- Date: � Signature z�/_' `� ,-�;.• a ,� ',� L �/ Date Z� � �i ., � � f Firm By: 'L Cit� of Y�lm (36 ) 458-8402 REC#: 00147505 12/24/2013 11 :01 AM OPER: CO TERM: 001 REF#: 1221 TRAN: 33.00OU BUILGI2g 50CR�TS , Z0130369 � PFIILLIPS, JAMES 15621 92ND WAY SE MECH 29.50CR TENDERED: 29.50 CHECK APPLIED: 29.50- CHANGE: 0.00 Z�3 0-�� CITY OF YELM RESIDENTIAL BUILDING PERMIT APPLICATION FORM Project Address: 15621 92ND WAY SE Parcel#: 55360001300 Subdivision: Lot#: Zoning; New Construction � Re-Model/Re-Roof/Addition Home Occupation Sign Plumbing �Mechanical Mobile/Manufactured Home Placement Other Project�escription/scope otwork: REPLACE 60K GAS FURNACE Project Value: �4057.70 Building Area (sq. ft) 1 S�Floor 2"d Floor Garage Deck Basement Carport Patio #Bedrooms_ #Bathrooms_ Heatin�AS/OTHER or ELECTRIC (Circle One) Are there any environmentally sensitive areas located on the parcel? If yes, a completed environmental checklist must accompany permit application. BUILDING OWNER NAME: �iM PHi�uPs ADDRESS �5621 92ND WAY SE EMAIL CITY vE�M STATE WA ZIP 9859� TELEPHONE 360-481-2962 ARCHITECT/ENGINEER LICENSE# ADDRESS EMAIL CITY STATE ZIP TELEPHONE GENERAL CONTRACTOR wESCO TELEPHONE $00-398-4663 ADDRESS 3ga9,gscr,s�sw EMAIL CITY LYNNWOOD STATE wa ZIP ssoss F,q)( CONTRACTOR'S LICENSE# WASHIES9710B EXP DATEsi�S CITY LICENSE# 30501 PLUMBING CONTRACTOR TELEPHONE ADDRESS EMAIL CITY STATE ZIP FAX CONTRACTOR'S LICENSE# EXP DATE CITY LICENSE# MECHANICAL CONTRACTOR TELEPHONE ADDRESS EMAIL CITY STATE ZIP FAX CONTRACTOR'S LICENSE# EXP DATE CITY LICENSE# Copy of mitigation agreement with Yelm Community Schools, if applicable. I here c i that the above information is correct and that the construction on,and the occupancy and the use of the abov desc i d property will be in accordance with the laws,rules and regulations of the State of Washington and the City o Yel . �QG �� 4 �°�`� ApplicanYs Signature Date Owner/Contractor/Owner's Agent/Contractor's Agent (Please circle one.) All permits ar� non-transferable and will expire if work authorized by such permit is not begun within 180 days of issuance, or if work is suspended or abandoned for a period of 180 days 105 Yelm Auenue West (360)458-3835 PO Box 479 (360)458-3144 FAX Yelm, WA 98599 www.ci.yelm.wa.us ��������� �����4 ���a 'i' � �� a �'=__� � I � � � � � �l � -`�„�=s December 11, 2013 City of Yelm Attn: Gary Carlson 105 Yelm Avenue W PO Box 479 Yelm, WA 98597 Gary: Please process attached mechanical permit. We act as permit expeditors for our clients and as such would ask that you do not mail the permits to the address on the application. Instead, please mail them to the address below: Northwest Permit Inc. 1345 Gulf Road Point Roberts, WA 98281 Please see attached check for payment of the permit fees. Please be informed that we, Northwest Permit Inc. have taken over the permitting services for Washington Energy Services. Please update your contact information with the above contact address. If you hav y questions please contact me at 360.945.2787 or Sheila@nwpermit.com any h nk , S ' onty Northwest Permit Inc. �,.,,� , ., .. �� Washington _� ��� �� �-: a��� ������� � , Ener+gy Services `�.` � � �� �� ��� �� � �� . .�.. � Save Energy.Live Better. Duct Leakage Test Results (Existing Construction) _ Permit#: _����� �-�L`'�3 G��� c/ � House address or lot number: � {�� �� s� , y Ic�ty: ��e �w� z�p: ���� � • Cond. Floor Area (ft2): �Uti° ❑ Duct tightness testing is not required for this residence per exceptions listed at the end of this document Test Result: �_ � CFM@25Pa � Ring (circle one): Open 1 � 3 Duct Tester Location: ' (� (Ylt�(' � � Pressure Tap Location: � G�.l'i�P Company Name: �/J�� ,-� Duct Testing Technician: � ' � "� Technician Signature: Date: � — �3 � Phone Number. � --L _ Washington State Energy Code reference: 101.3:2.6 Mechanical Systems:Those parts of systems which are altered or replaced shall comply with Section 503 of this Code when a space- condi6oning system is altered by the installation or replacement of space-conditioning equipment (including replacement of the air handler,outdoor condensing unit of a split system air conditioner or heat pump, cooling or heaGng coil,or the fumace heat exchanger),the duct system that is connected to the new or replacement space- conditioning equipment shall be sealed,as confiRned through field verification and diagnostic testing in accordance with procedures for duct sealing of existing duct systems as specified in the RS-33,to one of the following requirements. Exceptions: 1. Duct systems that are documented to have been previously sealed as confirmed through field verification and diagnostic testing in accordance with procedures in RS-33. 2. Ducts with less than 40 linear feet in unconditioned spaces. 3. Existing duct systems constructed, insulated or sealed with asbestos.