Loading...
20070135 Permit Pkg 10302013 '�'`�,o� T"�p,�`�' City of Yelm Permit ►vo.: 20070135 .a '� a � Community Development Department Issue Date: 10/30/2013 (Work must be completed within 180 days) Building Division Phone: (360)458-8407 L Fax: (360)458-3144 Applicant: Name: YELM DENTAL CLINIC Phone: Address: 502 YELM AVENUE WEST YELM WA 98597 Property Information: site Address: 502 YELM AVE W Owner: YELM DENTAL CLINIC Assessor Parcel No.: 21724142200 Subdivision: Lot: Contractor Information: Name: YELM DENTAL CLINIC Phone: Address: JUDD SHERMAN 502 YELM AVENUE WEST YELM WA 98597 Contractor License No.: Expires: 0/00/0000 Project Information: Project: TODAY'S DENTAL Description of Work: Demo existing 2 buildings on 2 parcels, new 4530 sf dental office w/parking, site dev, street frontage improvements Sq. Ft. per floor: First Heat Type(Electric, Gas, Other): Second Third Garage Basement Fees: Item Contractor Fees SITE YELM DENTAL CLINIC $ 750.00 NEW COMMERCIAL BUILDING YELM DENTAL CLINIC $17,807.03 TOTAL FEES: $18,557.03 Applicant's Affidavit: I certify that I have read and examined the information contained within the application and know the same OFFICIAL USE ONLY to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of #Sets of Prints: Yelm regulations including those governing zoning and land subdivision,and in addition,all covenants, easements and restrictions of record. If applying as a contractor, I further certify that I am currently Final Inspection: registered in the State of Wa i to �- Signat e Date O� �, I�J Date: � Firm BY� Cit� of Y�lm (36 ) 458-8402 REC#: OQ142518 1U130/20i3 9:53 AM Of'ER: CO TERM: 001 REF#: 12623 TRAN; 33.00i)0 BUILDING PERMTTS 2Q070135 15,583.85CR YELM QENTAL CLINIC 502 YELM AVE W �Lq-CQM1 15,583.85CR T�NpEREG: 15,583.65 CHECK APPLIEQ: 15,583.85- CHANGE: � � O.OQ 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential . . • • r 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised February 2011 Project Address —�Z E E Date 5" 3'2�� The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability Code Location Building DepaRment ( ea,no,na) Section Com onent Information Re uired on Plans Notes HVAC REQUIREMENTS Sections 1401-1424 1411 Equipment Performance x.s 1411.1 Minimum efficiency Equipment schedule with type,capacity,efficiency �-1 x.s 1411.1 Combustion htg. Indicate intermittent ignition,flue/draft damper 8 jacket foss �-1 x.�►. 1411.1 Air-cooled chilter Provide total air and water chiiler capacity N.A. 1411.2.1 Water-cooled chiller Full-load and NPLV values adjusted for any non-standard conditions rr.�►. 1411.4 Pkg.elec.htg.&clg. List heat pumps on schedule x.A. 1411.5 Unenciosed Heat Indicate radiant heat system and occupancy controls 1412 HVAC Controls yos 1412.1 Temperature zones Indicate locations on plans �-2 xes 1412.2 Deadband control Indicate 5 degree deadband minimum �-1 x.A. 1412.3 Humidity control Indicate humidistat xes 1412.4 Setback and Shutoff Indicate thermostat with 7 day program capability 8 required setback �-1 x.A. 1412.4.1 Dampers Indicate damper location,leakage rate,control type,8 max.leakage x.a. 1412.4.2 Optimum Start Indicate optimum start controls x.�►. 1412.5 Heat pump control Indicate heat pump thermostant&outdoor lockout on schedule xo 1412.6 Combustion heating Indicate modulating or staged control xa• 1412.7 Balancing Indicate balancing features on pians �-2 xas 1412.8 Ventilation Control Indicate demand control ventilation for high-occupancy areas �-1 x.A. 1412.9 Loading Dock& Indicate enclosed loading dock&parking garage ventilation system Garage Ventilation activation and control method. r�.A. 1423 Thermostat interlock Indicate thermostat interlock on plans Yes 1432.2.1 Temperature Reset Indicate temperature reset method �'1 1413 AIr/Water Economizers N.A. 1412.1 Single zone systems Indicate multiple cooling stage control capability. xes 1413.1 Air Econo Operation Indicate 100°�capability on schedule M�1 N.A. 1413.1 Wtr Econo Operation Indicate 100°h capacity at 45 degF db 8 40 deg F wb x.�►. 1413.2 Wtr Econo Document Indicate max.OSA condition for design clg load&equipment performance data. x.A. 1413.3 Integrated operation Indicate capability for partial cooling N.A. 1413.4 Humidification Indicate direct evap or fog atomization w/air economizer 1414 Ducting Systems x.�►. 1414.1 Duct sealing Indicate duct design pressures,sealing,and testing requirements x.A. 1414.1.2 Low press.duct test Indicate applicable low pressure duct systems shall be leak tested rt.s. 1414.1.3 High press.duct test Indicate high pressure duct systems shall be leak tested,and identify the location of this ductwork on plans Yes 1414.2 Duct insulation indicate R-value of insulation on duct �-1 1415 Pfping Systems x.�►. 1415.1 Piping insulation Indicate R-value of insulation on piping omp e on equ remen xas 1416.3.2 System Balancing Indicate air and water system balancing requirements �-Z Ys• 1416.3.3 Functional Testing Provide sequence of operations and test procedures. �-1 x.A. 1416.3.4 Documentation Indicate O&M manuals,record drawings,staff training N.A. 1416.3.5 Comm.Report Indicate requirements for final commissioning report x.A. 1416.4 Compliance Chklist Submit to building official upon substantial completion. xes Mecha�ical Summary Fortn Completed and attached. Equipment schedule with types,inpuUoutput, �' efficien ,cfm,h ,economizer R�C���J� MAY 2 0 2013 �