20130172 Permit Pkg 11042013 .
"f''�o� TH�p,�''`�" City of Yelm Permit No.: 20130172
�
� � Community Development Department Issue Date: 11/04/2013
(Work must be completed within 180 days)
Building Division
Phone: (360)458-8407
L
"'•°"'"°T°" Fax: (360)458-3144
Applicant:
Name: PUGET SOUND BUILDERS ASSOC Phone: 253-202-5025
Address: 11012 CANYON ROAD E, STE. 8
PUYALLUP WA 98373
Property Information:
site Address: 14464 99TH WAY SE Owner: PUGER SOUND BUILDERS
ASSOC
Assessor Parcel No.: 78640116900 Subdivision: TAHOMA TERRA Lot: 169
Contractor Information:
Name: PUGET SOUND BUILDERS ASSOC Phone:
Address:
11012 CANYON RD E, STE 8
PUYALLUP WA 98373
Contractor License No.: PUGETS6903MH Expires: 7/31/2013
Project Information:
Project: NEW RESIDENTIAL BUILDING
Description of Work: LOT 169, PLAN 2198
Sq. Ft. per floor: First ggg Heat Type(Electric, Gas, Other): GAS
Second 1210
Third
Garage 440
Basement
Fees:
Item Contractor Fees
NEW RESIDENTIAL BUILDING PUGET SOUND BUILDERS ASSOC $17,055.13
MECHANICAL KLIEMANN BROS. $ 84.75
PLUMBING RAINIER VIEW ROOTER $ 118.00
TOTAL FEES: $17,257.88
ApplicanYs Affidavit: OFFICIAL USE ONLY
I certify that I have read and examined the information contained within the application and know the same
to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of #Sets of Prints:
Yelm regulations including those governing zoning and land subdivision,and in addition, all covenants,
easements and restrictiqn,9 of record. If applying as a contractor,I further certify that I am currently Final Inspection:
registered in the State of Washingtqn.
6 �
Signature � "� :�,_� l ��°�� Date i/ y���_ Date:
Firm BY�
YELM �POMBOXT476CHOOLS
YELM WA 98597
Cit� of Yelm Clerk: Croy
(36 } 458-84Q2 Terminal: ZZ8089(Reprint)
Recei pt:
RCC#; 00142913 11J04/2013 1z,p7 pM Manual Receipt:
OPER: CO TERM: U01 NPS BLD ASSOC
REF#; 7266 NPS BLQ ASSOC
PUGET 50UND, BUILDERS ASSOC
TRAN: �3,OOflO BUILDING PERMITS
2U13U172 1%,257.88CR �
PUGET SOUND BUILDERS ASSOC 11/412�13 11:31 AM
14464 99TH WAY SE `Price
BLD�-RES1 17,055.13CR q��Item �_�____.��_ -----
MECH 84.15CR 3015,00
P� 118.00CR 1 CPF MITIGATION
MITIGATION
TENqERED: 17,257.88 CHECK 05-Q24/LOT 169/14464 99TH WAY SF; YELM
APpLIED; 17,257,88-
CHANGE: � 0.00 Subtotal: 3010.00
Tax: 3015.00
Total:
Check 3015.00
7267
Change Due: 0.00
REPRINT RECEIpT
THANK YOU
�������.
CITY OF YELM
RESIDENTIAL BUILDING PERMIT APPLICATION FORM
ProjectAddress: C�_�p�_ ���u'1 WC�,� 5�= Parcel#:_]���}��� p��
i 'T`
Subdivision:�G�Il;��1ca T�tY4 Lot#._ L���_ Plan#:_,�� �p __ Zoning:
�IVew Construction � ! Re-Model/Re-Roof/Addition i ; Home Occupa6on Sign
! Plumbing � � Mechanical �� Mobile/Manufactured Home Placement � ! Other
Project Description/Scope of Work:_ ����5(1���t.�' `7t'
Project Value:_�� �b�
—T
Building Area(sq.ft) 151 Floor �d� 2"d Floor�� Garage yy U Deck
Basement Carport Patio � c�•O
#Bedrooms� #Bathrooms�li? Heating: AS/OTHE or ELECTRIC(Circle One)
Are there any environmentally sensitive areas located on the . �
If yes,a completed environFrrental checklist must accompany permit applicaticn.
BUILDING OWNE NAME: • Lt� ' ��
ADD SS �11;i � ' � AIL C� z. � �
. .• �c�V t9n�---''-�►-�l�'1
CITY STATE�(�_ZIP � TELEPHO�. t^ '-
ARCHITECT/ENGINEER LICENSE#
ADDRESS EMAIL
CITY STATE ZIP TELEPHONE
GENERALCONTRACTOR TELEPHONE , -
ADDRESS EMAIL t� ',Q �j�ay�1,���(h
CITY STAT ZIP FAX
CONTRACTOR'S LICENSE# ' �� 1�EXP DATEI ' CITY LICENSE#
PLUMBING CONTRACTOR TELEPHONE " - �
ADD SS EMAIL
C�T1'R��STATE 1N ZIP "1 FAX
CONTRACTO 'S LICENSE# '�i' EXP DAT CITY LICENSE# - �,�
MECHANICAL CONTRACTOR I n ' "i TELEPHONE_ S3�-�i�7—Q 5
ADDRESS �-i?u'j�1� EMAIL
CITY '�t;�i01M v STATE 1�i�,_ZI P FAX
CONTRACTOR'S LICENSE# t?C� EXP DATE� "CITY LICENSE# � ^ �
Copy of mitigation agreement with Yelm Community Schools, if applicable.
I hereby certify that the above information is correct and that the construcGon on,and the occupancy and the use of the
above escribed pro will be in accordance w(th the laws,rules and regulations of the State of Washington and the
City elm.
. � / �
Applica 's Signa ure Dat
Owner/Contractor/Owner's Agent/Contractor's Agent(Please circle one.)
All permits are non-transferable and will expire if work authorized by such permit is not be�gu�
within 180 days of issuance, or if work is suspended or abandoned for a period of 180 days
' `
� �.���� �
IO Yelm Auenue Wesi (360)45&3835
Yelm,WA 98597 MAR 2 7 2013
(360)458-3144 F
www.ci.yelm.wa.us
BY:
�r .. . .,. .
� � /J � � ��
��� 1�9
PUGET SOUND BUILDERS ASSICII�.TIC�N, LLC
TAHOMA TERRA
14464 99th WAY SOUTH EAST YII,M,WA 9859?
PARCEL NUMBER: 7864011690
56.01 '
_ _ _ _ ___--
-� s' ,�-__._._�a>_..___. ___�.
a'x i o' __- _--- __
��-�' � � �
DRY WELL��_.� � , � , ` �`;.
� � �, � � s
1! �/� PA7t0 (
__ GSL �
o � ._�._._, . _
� � � � � .�......�.,_. .
� �J.� /A � � � �
� �f �� � o � � �I�� � l � �
� � p o0 � CV �' � � � W
� � `� � Z � � � � �
n I � � C3..' r� � I � .� � �
�-- r � � `d' d" � � � �
� � �� � � i � � � �
� 6'-10" m °: Z
° �� a� I � �� � � o
a � I- o� ( i ( I I F--
l
, �
� � I �, � ` � � � °
� � � � � ! � I ;
i a � � � j ;
' _; .
E � � � � �r __ ____"�. - � �:��„g;,1 ' �� � t�
! �,_-_ � �- � ;
71"W x 103"L x 65"D � o '� 20�BSB ! ! � r;, ..�_...-��Z- /�
_ _.__ _._
Y£LM STEP TANK�_. _• > ! � �,j �
-I ,;� "
S' � i
- — r-�.�:x... ,. ._
I� --� __ 3'�„ 1 / "�'
' U71 !TY EASEM NT � ��.5=e�i ar�k Excavation In Violation�f
SiDEWALK i 37 j_>- --- — rhe �equired s' Minimum Set Back To
PLANTING �? ; i �`ll�`�,.� �aundation ShaiE Be Back �ilied With
CARSON WATER ����
BOX METER
7' ikE l.
99th �IVAY SE '�„� Fror�t Porch Foundation And Step Tank
! Location Shail Be Staked For Se# Back
inspection.
�r�. � �-� '� 1'�-= _-1'' l..�.�" L. „�;�` — ,
.�__G C� �.! '�� d�� t � ����
5 I T� �'1���l �o�tN
QZ�?I� ShzrGes�a,n 15?�5>���?I 10���`�IZisi��r�;et P��<1�-�1.4rA � ' .... ., .,,,.. . ...� SCALE I' - 20�
},9 oRbur+�oa� wir, r�cr�
�"�l.;L�� � �� L iJ�,3 4.03.tP�3 JL9 PE6A-TN�IGt7A TEl2eA
�k`3Y: �
.
L�� 1�9
PUGET S�UND BUILDERS ASSICI.A.TION, LLC
T.AHOMA TERRA
14464 99th WAY SOUTH EAST Y�ELM,Wi�i gggg7
PARCEL NUMBER: 7864011690
56.01 '
a'x�o'
1 `' _ _ 3a'--- _ _-...�....__.._ _
DRY WE�.L �._ .� I N
I °-
� �
�' r�� PpT:O I �
� __ G3L � . �___ _ 1
o � � N i �
(�w i1 � � � �
� l � z '�- � � ( i
I �� � � � I j
� �
� � tiJ/
� I Q �� �� �f I I � � � /�
�'^" � (
� �}' Q. .�1 I ( I V I
Q LI� �C,L� �� { VI (Ti
� _,,,��i —��" � I W p� �
°� �;� �� � � �� � o
� � � �a 1 ^ � I �
i � � ~
! ( � I i I I I � �
i
I 1 ( I .�' �
� � , � !
�
�
; i . _ ___._ �_ _ �_______ _I
—����}- o -� �
!) 11 �1 � �_�± ""l � N !
79 W x 103 L x 65 D � 0 20�BS8 I � ., N
Y�L.M STEP ?ANK L__ ._ _� > � j � Q -p
15 ;.- �- ,I/ / • �
j � __ 3'_5>' 1 / �
J / �
' UTI !TY EASEM N7 � _� str�� 1�riK Exiavatic�r3 3n Vioia#ior{t3#
SIDEWALK i 3 7 �"- -- --� The Requ�rec!5° iUiinimum Set Bacic Tm
PLANTING _� (-� ����+�c�atic��ai Si�a�! 8e Se�ck Fiiled With
CARSON WATER ���
s�X METER TULlP
9�th WAY SE ���� E-
ru���t F'�r{:�t'� Fr�i�tr���arior�� �r��� 5te � T�r�k
� � — i r�, at;r>r 4�3a91 Be Staked �t�r Set Back
r�—� � ���� ����f � ���� �r,s�ectfon
`-� I L � � r� ��
i:�,
.,,: _
._�____�n�.._._ ��
�I�� I ��� NOR1'N
Q201� SnerGeS�, 2>�5�!I5?i IG��512lst��reet I',�tla,-d.WA, •.. . ..... SCALE (' = 20'
�� caaur�oa�• �ir, rx.%�cr ti
� �+��.<
M� 4.93.YCi3 11,5 PbBA-TIJJCfiA}��y+,p
BY:
Prescriptive Energy Code Compliance for Single Family and Duplex Housing:Zone 1
Project lnformafion Contact Information
Plan 2196/2 Puget Sound Builders Association
2198 sf 2 story
Yelm WA
This set of forms has been developed to assist permit applicants documenting compliance with the
Washington State Energy Code, (2009 edition). This set is for structures built under the IRC and located
in Climate Zone 1.
The following forms provide much of the required documentation for plan review. The details noted here
must also be shown on the drawings (WSEC 104.2).
This form is not a substitute for the energy code itself. To obtain a copy of the energy code,
go to the following web address. http://www.energy.wsu.edu/code
Glazing Glazing U-Factor poor 9 z Vaulted Wall12 Wall� int4 Wall• ext4 s
Option Area10: Ceiling 3 Above Below Below Floor
%of Floor Vertical Overhead�l U-Factor Ceiling Grade Grade Grade
R-49 or R-21 R-21
OI 13% 0.34 0.50 0.20 R-38 R'38 Int.' TB R-10 R-30
R-49 or R-21 R-21
OOII 25% 0.32 0.50 0.20 R-38 R-38 Int, ,I,B R-10 R-30
R-49 or R-21 R-21
OIII Unlimited 0.30 0.50 0.20 R-38 R-38 Int.� TB R-10 R-30
Adv.
See WSEC table 6-1 for footnotes
Glazing Schedule Attached to Document
� Does not apply. (S�E fNSTRUCtIONS) Usin�Prescriptive Option III.All glazing
and doors meet maximum U-factor.Alternate heating size method submitted.
0 Option I or II,Glazing to floor area limit(WSEC 602.7.2)
❑ Area weighted window,skylight or door U-factor(WSEC 602J.2)
0 As part of the heating system sizing calculation (IRC M1401.3 &WSEC 503.2.2)
Radiant slab:
❑ R-10 foam insu:lation, continu:ous with thermal break(WSEC 502.4.4.9)
Chapter 9 Options Total of 1 Credit Required
Opt. Opt. Description
1a High Efficiency HVAC Equipment 1 1.0 �
1 b High Efficiency HVAC Equipment 2 ❑
1c High Efficiency HVAC Equipment 3 ❑
2 High Efficiency HVAC Distribution System ❑
3a Efficient Building Envelope 1 ❑
3b Efficient Building Envelope 2 �
3c Super-Efficient Building Envelope 3 ❑
4a Air Leakage Control and Efficient Ventilation ❑
4b Additional Air Leakage Control and Efficient Ventilation ❑
5a Efficient Water Heating ❑
5b High Effieciency Water Heating ❑
6 Small Dwelling Unit ❑
7 Large Dwelling Unit ❑
8 Renewable Electric Energy *1200 kwh ❑
Total Credits 1.00
WSEC Prescriptive Worksheet(2010 edition)Zone 1 WSUEEP10-010 Copyright 2010
Glazing Schedule
Project lnformation Contact Information
Plan 2196/2 Puget Sound Builders Association
2198 sf 2 story
Yelm WA
Conditioned Floor Area 2198 Sum of UA for Heating System Sizing 119.5
Sum of All Gfazing Areas From Below 310
Glazing to Floor Area Ratio 14.08% 602.7.2 Exception Ratio (not to exceed 1%)�
Exterior poors
Pian Component Door Percent Width Height Glazing Door poor
ID Description Ref. U-factor Glazed Qt. Feet �"°n Feet �"0n Area Area UA
BLIDER 0.32 1 8 8 64.0 20.5
One Exempt Swinging Door<24 Square Feet
Sum of G/azing Area, Door Area, and UA (do not include exempt door) 64.0 20.5
Area Weighted U= UA/Area 0.32.
Sum of Area and UA for Heating system size only(include exempt door) 64.0 20.5
Vertical Glazing (Windows, Glazed doors using Exception 602.6#1)
Plan Gomponent Glazing 1Nidth Height Glazing
ID Description Ref. U-factor Qt. Feet �"`n Feet ��°n Area UA
EXTERIOR WINDOW 0.32 1 4 6 3 13.5 4.32
EXTERIOR WINDOW 0.32 2 2 6 5 25.0 8.00
EXTERIOR WINDOW 0.32 4 2 6 2 6 25.0 8.00
EXTERIOR WINDOW 0.32 1 8 5 40.0 12.80
EXTERIOR WINDOW 0.32 3 4 4 48.0 15.36:
EXTERIOR WINDOW 0.32 1 2 3 6.0 1.92
EXTERIOR WINDOW 0.32 2 3 3 6 21.0 6.72.
EXTERIOR WINDOW 0.32 2 5 3 6 35.0 11.20
EXTERIOR WINDOW 0.32 1 8 6 48.0 15.36
EXTERIOR WINDOW 0.32 1 6 2 12.0 3.84
EXTERIOR WINDOW 0.32 2 1 1 2.0 0.64
EXTERIOR WINDOW 0.32 1 5 4 20.0 6.40
EXTERIOR WINDOW 0.32 1 1 6 6.0 1.92
Sum of Area and UA 301.5 96.48
Area Weighted U= UA/Area 0.32
WSEC Prescriptive Worksheet(2010 Edition)
WSUEEP10-010 Copyright 2010
Overhead Glazing
Plan Component Glazing Width Height
ID Description Ref. U Qt. Feet �"°n Feet �"°n Area UA
SKYLIGHT 0.32 1 2 4 8.0 2.6
Sum of Area and UA 8.0 2.6
Area Weighted U= UA/Area 0.32
Doube Glazed Garden Windows Section 602.72 Exception
Plan Component Width Height
ID Description Qt. Feet �"°n Feet ��°" Area UA
Sum of Area
Sum of Area X 3(This total is automatically included in the glazing area totaL)
Glazing UA for Heating System Size Only=Area X 0.63
WSEC Prescriptive Worksheet(2010 Edition)
WSUEEP10-010 Copyright 2010
Simple Heating System Size: Climate Zone 1
Project Information Contact Information
Plan 2196/2 Puget Sound Builders Associatior
2198 sf 2 story „
Yelm WA
Indoor Design Temperature 70
Outdoor Design Temperature 21
Design Temperature Difference (�T)
4T=Indoor-Outdoor Design Temp 49
Conditioned Floor Area 2198
Conditioned Volume 15273
Glazing
Copy Sum of UA from Glazing Schedule 120
Attic U-Factor X Area = UA
R-49 0.027 1210 32.7
R-38 Advanced 0.026
Single Rafter or Joist Vaulted Ceilings
U-Factor X Area = UA
R-38 Vented 0.027 � �
Above Grade Walis U-Factor X Area = UA
R-21 0.056 2464 138.0
Floors U-Factor X Area = UA
R-30 0.029 988 28.7
Below Grade Walls U-Factor X Area = UA
2' Depth Walls 0.042
3.5' Depth Walls 0.041
7' Depth Walls 0.037
Slab Below Grade F-Factor X Length = UA
2' Depth 0.59
3.5' Depth 0.64
7' Depth 0.57
Slab on Grade F-Factor X Length = UA
R-10 2' perimeter 0.54
R-10 Full- Heated 0.55
Sum of UA 319
Envelope Heat Load 15622 Btu / Hour
Sum of UA X OT
Air Leakage Heat Load 8082 Btu /Hour
((Volume X 0.6)X 4T)X.018))
Building Design Heat Load 23705 Btu/ Hout
Air Leakage+Envelope Heat Loss
Building and Duct Heat Load 1.15 27261 Btu /Hour
If ducts are located in unconditioned space:Sum of Building Heat Loss X 1.15
If ducts are located in conditioned space:Sum of Building Heat Loss X 1
Maximum Heat Equipment Output 150% 40891 Btu / Hour
Building and Quct Heat Loss X 1.50
WSEC Prescriptive Worksheet(2010 Edition)
WSUEEP10-010 Copyright 2010
ALPHA ENG/NEER/NG
12701 111 TH Ave E
Puyallup WA 98374
253 241.3334
March 25, 2013
Attention: City of Yelm, Building Official
Puget Sound Builders (PSBA Homes) is authorized to submit our Plan # 2198/2 for a basic
plan process on Lot 169 In Tahoma Terra.
Any revisions or alterations must be authorized by Level Design LLC prior to commencing
work.
Sincerely,
George Gergis P.E.
Civil Structural GEO Technical
�E�EI'V��
MA� 2 7 2013
�3Y: