20140113 Full Size Site Plan 01282014■ ■
0
obile
WILKENSON ROAD /RAILWAY
16220 RAILWAY ROAD SE
YELM, WA 98597
SITE NUMBER: SE05198D
LATITUDE 46.945964
LONGITUDE - 122.596944
GENERAL LOCATION MAP
DRIVIING DIRECTIONS
PROJECT TEAM
PROJECT DESCRIPTION
DRAWING INDEX
f ¢w
Y 4
—
sm s
vserwae a q4 _ aum &s
�^ ?
Luigmtra
��Iy
PaTC
yenta
ggg
Ohl g"
A. x�
®
IfthA. SE "a.
l.aaeme Se
yi
Na
s�
FROM T- MOBILE BOTHE -LL 40FFICE
1: START OUT GOING SOUTH ON NORTH CREEK PKWY TOWARD NE
195TH ST. 0.1 MILES
2: TURN RIGHT ONTO NE 195TH ST. 0.2 MILES
3: MERGE ONTO 1 -405 S, VIA THE RAMP ON THE LEFT TOWARD
RENTON. 24.4 MILES
4: 105 S BECOMES WA -518 W. <0.1 MILES
5: MERGE ONTO 1 -5 S T(DWARD PORTLAND, 37,5 MILES
6: TAKE EXIT 116 TOWARD MOUNTS ROAD /OLD NISQUALLY. 0.5
MILES
7. TURN LEFT ONTO NI£;QUALLY RD / OLD PACIFIC HWY. CONTINUE TO
FOLLOW OLD PACIFIC yW SE 5.5 MILES
8: TURN LEFT ONTO ST -CLAIR CUT -OFF RD SE / WA -510, CONTINUE TO
FOLLOW WA -510. 9.3 MILES
9'. TURN LEFT ONTO 1 S'T ST N, 0,3 MILES
10: TURN RIGHT ONTO 4RAILWAY RD NE. 0.2 MILES
DISTANCE. MILES
APPROXIMATE TE T TRAVEL_ TIME 1 HOUR 33 MINUTES
CONTACT TITLE
CONTACT INFORMATION
T- MOBILE PROPOSES TO ADD (2) COVP (1 @ TOP, 1 @ BOTTOM), (2)
FXFB, (3) FRIG, (6) DIPLEXERS. AND (1) HYBRID CABLE. T- MOBILE
PROPOSES TO REPLACE EXISTING (3) DUAL ANTENNAS WITH NEW (3)
TMBXX6516-R2M ANTENNAS.
EXISTING (10) COAX FEEDERS, EXISTING (3) QUAD ANTENNAS, AND
EXISTING (6) TMA TO REMAIN.
(12) TOTAL CABLES ROUTE UP TOWER.
DWG', DRAWING DESCRIPTION:
T -1 TITLE SHEET & PROTECT DATA
G -1 GENERAL NOTES
A -1 OVERA LL PLAN
A -1 1 ENLARGED SITE PLAN
A-2 EXISTING SITE ELEVATION
A -2.1 PROPOSED SITE ELEEVATION
A3 GENERAL DETAILS
Ad GENERAL DETAILS
E -1 ELECTRICAL GROUMDING PLAN
E -2 ELECTRICAL GROUPVDING DETAILS
RF -1 RE DETAILS
RF -2 RE DETAILS
DWG'. DRAWING DESCRIPTION',
PROPERTY RAILWAY ROAD PROJECTS LLC
OWNER: 11710 VAIL RD BE
YELM. WA 98597
TOWER RAILWAY ROAD PROJECTS LLC
OWNER: 11710 VAIL RD SE
YELM, WA 98597
PROGRAM TELCOPACIFIC
MANAGER ', AARON IMPER
14636 NE 95TH STREET
REDMOND WASHINGTON 98052
PHONE # (425) 622 -7874
PROJECT INFORMATION
THIS IS UNSTAFFED AND RESTRICTED EQUIPMENT AND WILL BE
USED FOR THE TRANSMISSION OF RADIO SIGNALS FOR THE
PURPOSE OF PROVIDING PUBLIC CELLULAR SERVICE.
T-MOBILE CERTIFIES THAT THIS TELEPHONE EQUIPMENT FACILI
WILL BE SERVICED ONLY BY T- MOBILE EMPLOYEES AND THE WORK
ASSOCIATED WITH ANY EQUIPMENT CANNOT BE PERFORMED BY
HANDICAPPED PERSONS, THIS FACILITY WILL BE FREQUENTED
ONLY BY SERVICE PERSONNEL FOR REPAIR PURPOSES, PURSUANT
SE THE AMERICANS WITH DISABILITIES ACT PT FROM APPENDIX B
SECTION 4.11. (5)(b), THIS FACILITY IS EXEMPT FROM THAT ACT,
NO POTABLE WATER SUPPLY IS TO BE PROVIDED AT THIS LOCATION.
NO WASTE WATER OR SOLID WASTE WILL BE GENERATED AT THIS
LOCATION .
T- MOBILE MAINTENANCE CREW (ONE PERSON) WILL MAKE AN
AVERAGE OF ONE TRIPPER MONTH ATONE HOUR PER TRIP.
CONSTRUCTION TELCOPACIFIC
MANAGER'. ADAM GLENN
14636 NE 95TH ST
REDMOND, WA 98052
PHONE #'. 509- 741 -0568
ZONING INFORMATION
SITE NUMBER: SE05198D
CONSULTING B.J. THOMAS, P.E.
ENGINEER', 760780TH AVE NE
MARYSVILLE, WA 98270
MOBILE #' 206 -851 -1106
SITE NAME: WILKENSON RD /RAILWAY
SITE ADDRESS'. 15220 RAILWAY ROAD BE
YELM, WA 98597
VICINITY MAP
'� Ydm We1K
fteciamaROn r
{a`II'7
3g
2 A9ue7a .
aye_.
��4 ° _
1110
4
9 - r'
p
ro yb
a°
¢�
yw �,an,mirc
µa luorp@ RY A,n�
P"
P"
PARCEL #: 64300700600
CURRENT ZONING: LIGHT INDUSTRIAL
SITE
ACQUISITION'.
TELCOPACIFIC
BARBARA CHANEY
14636 NE 95TH STREET
PHONE# REDMOND, 6 310 0477
APPROVAL/SIGN OFF OF CONSTRUCTION DRAWINGS
JURISDICTIO, TBD
N'
REV. PER REDLINES
REVIEWERS SHALL CLEARLY PLACE INITIALS ADJACENT TO EACH REDLINE NOTE AS
DRAWINGS ARE BEING REVIEWED.
GOVERNING CODE 2012 IBC
CODE COMPLIANCE
4/25/2013
BUI LDING TYPE'. - -.
CONSULTANT GROUP SI GN OFF
ALL WORKAND MATERIALS SHALL BE PERFORMED AND INSTALLED IN
ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING
CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES.
NOTHING ON THESE PLANS IS TO BE CONSTRUCTED TO PERMIT
WORK NOT CONFORMING TO THESE CODES:
2012 INTERNATIONAL BUILDING CODE
2012 INTERNATIONAL MECHANICAL CODE
SITE TYPE . UINSTAFFED TELECOMM FACILITY
LANDLORD'S REPRESENTATIVE'S DATE'.
ZONING', TELCOPACIFIC
BARBARA CHANEY
14636 NE 95TH STREET
REDMOND, WA 98052
PHONE #:206- 310 -0477
CONSTRUCTION COORDINATOR DATE'.
UTILITY PURVEYOR
POWERCOMPANY'.
ESE
PROJECT MANAGER. DATE',
SITE ACQUISITION: DATE.
ZONING. DATE:
RE ENGINEER:
T- MOBILE
DARRYL SALK
19807 NORTH CREEK PKWY N
BOTHELL, WA 98011
MOBILE #425- 770 -0006
wl«ay Re 5E N
2
J 0 Jew�a Name W �^
4. Pcotecnntai
a} G1°"A
°O aeayeaesw
�e �'�
�y r
9
h.� R6` ria
'P
} $ b
Yelm p�
�C' CmemAe �
SF'
3 �'e
A'. 'aD`
a A°
�'c
� e
el Ave SE f aye
9
1wlrt Way SE
TELCO COMPANY:
QWEST
2012 INTERNATIONAL FUEL GAS CODE
2012 NFPA 54 - NATIONAL FUEL GAS CODE
(PROPANE INSTALLATIONS ONLY)
2011 NFPA58- LIQUEFIED PETROLEUM GAS CODE
(PROPANE INSTALLATIONS ONLY)
2012 INTERNATIONAL FIRE CODE
2012 UNIFORM PLUMBING CODE
2011 NATIONAL ELECTRICAL CODE
2007 NATIONAL ELECTRIC SAFETY CODE
LOCAL BUILDING CODE ORDINANCES
ANSI- 101- UIESAF G
222
NFPA- 101 -LIFE SAFETY CODE
RE ENGINEER'. DATE:
,� CALL 3 WORKING DAYS BEFORE YOU DIG
_ 811
UTILITIES UNDERGROUND LOCATION CENTER
L (ID,MT,ND.OR.WA)
�
ELECTRIC RED TEUCATV- ORANGE
snTRACTRIC )ATAUTRFNHINCrIACFCURuer SEWER GREEN PROPOSED WHITE
otiTnncTOS�L R EN rONIASTeiuu.cdkunrvce GASIOIL YELLOW WATER BLUE
wmicuaarHT OSnn sTarvonos SURVEY -PINK
LEGAL DESCRIPTION
SECTION 19 TOWNSHIP 17 RANGE 2E QUARTER SW NE PLAT
MCKENNA IRRIGATED TRACTS BLK 7 LT 5 SWLY 10F & LT 6
DOCUMENT 099 /044
ETM in •Mobile•
WILKENSON
ROAD /RAILWAY
SE05198D
16220 RAILWAY ROAD SE
YELM, WA 98597
BUILDING PERMIT
= REVISION HISTORY:
NO. DATE: DESCRIPTION: CHK. APPV.
BY: BY:
=PLANS PREPARED BY:
B. J. THOMAS, P.E.
7607 80TH AVE HE
MARYSVILLE, WA 98270
206- 851.1106
=DRAWN BY: CHK. BY: =APPV. BY:-
AAL BJ KC
.AV
?M
a
is
NEW RADIO EQUIPMENT & NEW ANTENNAS.
= DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF
DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR
DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED
CLIENT IS STRICTLY PROHIBITED.
NO TITLE:
TITLE SHEET
= DRAWING NUMBER:
T -1
JAN 2 N!,.
3
1/15/2014
UPDATE CODE COMPLIANCE&
PROJECTTEAM
BHT
Al
Q5
/1 512 01 3
REV. PER REDLINES
BJT
KC
4/25/2013
ISSUED DESIGN REVIEW
BJT
KC
=PLANS PREPARED BY:
B. J. THOMAS, P.E.
7607 80TH AVE HE
MARYSVILLE, WA 98270
206- 851.1106
=DRAWN BY: CHK. BY: =APPV. BY:-
AAL BJ KC
.AV
?M
a
is
NEW RADIO EQUIPMENT & NEW ANTENNAS.
= DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF
DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR
DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED
CLIENT IS STRICTLY PROHIBITED.
NO TITLE:
TITLE SHEET
= DRAWING NUMBER:
T -1
JAN 2 N!,.
GENERAL NOTES:
1. DRAWINGS ARE NOT TO BE SCALED, WRITTEN DIMENSIONS TAKE PRECEDENCE, THIS SET OF DOCUMENTS IS
INTENDED TO BE USED FOR DIAGRAMMATIC PURPOSED ONLY UNLESS NOTED OTHERWISE. THE GENERAL
CONTRACTOR'S SCOPE OF WORK SHALL INCLUDE FURNISHING ALL MATERIALS, EQUIPMENT, LABOR AND ANY
REQUIREMENTS DEEMED NECESSARY TO COMPLETE INSTALLATION AS DESCRIBED IN THE DRAWINGS AND
OWNER'S PROJECT MANUAL.
2. THE CONTRACTOR IS RESPONSIBLE FOR ALL DIMENSIONS AND STANDARDIZED DETAILS THAT REQUIRE
MODIFICATIONS DUETOACTUAL FIELD CONDITIONS AND REQUIREMENTS MUST BE SUBMITTED TO AND APPROVED
BY, T- MOBILE WIRELESS REPRESENTATIVE PRIOR TO START OF WORK.
3. PRIOR TO THE SUBMISSION OF BIDS, CONTRACTORS INVOLVED SHALL VISIT THE JOB SITE TO FAMILIARIZE
THEMSELVES WITH ALL CONDITIONS AFFECTING THE PROPOSED PROJECT. CONTRACTORS SHALL VISIT THE
CONSTRUCTION SITE WITH THE CONSTRUCTION /CONTRACT DOCUMENTS TO VERIFY FIELD CONDITIONS AND
CONFIRM THAT THE PROJECT WILL BE ACCOMPLISHED AS SHOWN. PRIOR TO PROCEEDING WITH CONSTRUCTION,
ANY ERRORS, OMISSIONS, OR DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE
ARCHITECT /ENGINEER VERBALLY AND IN WRITING.
4, THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH CONSTRUCTION PRIOR
TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE CONSTRUCTION DRAWINGS /CONTRACT
DOCUMENTS.
5. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED IN THE CONTRACT DOCUMENTS. THE
CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES,
SEQUENCES. SAFETY, AND PROCEDURES FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT.
6. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENTAND MATERIALS ACCORDING TO MANUFACTURER'SNENDOR'S
SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE LOCAL CODES OR ORDINANCES TAKE PRECEDENCE.
7. ALL WORK PERFORMED ON THE PROJECT AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL
APPLICABLE CODES, REGULATIONS, AND ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH
ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY, MUNICI PAL AND
UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND STATE JURISDICTIONAL CODES BEARING ON THE
PERFORMANCE OF THE WORK.
8. GENERAL CONTRACTOR SHALL PROVIDE, AT THE PROJECT SITE, A FULL SET OF CONSTRUCTION DOCUMENTS
UPDATED WITH THE LATEST REVISIONS INVOLVED WITH THE PROJECT. THIS SET IS A VALID CONTRACT DOCUMENT
ONLY IF THE TITLE SHEET IS STAMPED IN RED INK "FOR CONSTRUCTION" AND EACH SUCCESSIVE SHEET BEARS THE
ARCHITECT'S /ENGINEER'S SIGNED WET STAMP.
9. THE CONTRACTOR IS RESPONSIBLE FOR ADEQUATELY BRACING AND PROTECTING ALL WORK DURING
CONSTRUCTION AGAINST DAMAGE, BREAKAGE, COLLAPSE, ETC. ACCORDING TO APPLICABLE CODES, STANDARDS,
AND GOOD CONSTRUCTION PRACTICES.
10. THE CONTRACTOR SHALL MEET ALL OSHA REQUIREMENTS FOR ALL INSTALLATIONS.
11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGES TO THE EXISTING CONSTRUCTION AND REPAIR
ALL DAMAGES TO BETTER THAN NEW CONSTRUCTION. THE CONTRACTOR SHALL NOTIFY THE CONSULTANT OF ANY
DAMAGE TO THE BUILDING SITE OR ANY ADJACENT STRUCTURES AROUND THE PROJECT. THE T- MOBILE
REPRESENTATIVE SHALL BE SOLE AND FINAL JUDGE AS TO THE QUALITY OF THE REPAIRED CONSTRUCTION. ANY
ADDITIONAL MODIFICATIONS WHICH MUST BE MADE SHALL BE MADE AT THE CONTRACTOR'S EXPENSE.
12. WHERE NEW PAVING, CONCRETE SIDEWALKS OR PATHS MEET EXISTING CONSTRUCTION. THE CONTRACTOR
SHALL MATCH THE EXISTING PITCH, GRADE, AND ELEVATION SO THE ENTIRE STRUCTURE SHALL HAVE A SMOOTH
TRANSITION.
13, THE CONTRACTOR SHALL MODIFY THE EXISTING FLOORS, WALL, CEILING. OR OTHER CONSTRUCTION AS
REQUIRED TO GAIN ACCESS TO AREAS FOR ALL MECHANICAL, PLUMBING, ELECTRICAL, OR STRUCTURAL
MODIFICATIONS. WHERE THE EXISTING CONSTRUCTION DOORS, PARTITIONS, CEILING, ETC.. ARE TO BE REMOVED,
MODIFIED, OR REARRANGED OR WHERE THE EXPOSED OR HIDDEN MECHANICAL, ELECTRICAL. SYSTEMS ARE ADDED
OR MODIFIED. THE GENERAL CONTRACTOR SHALL REPAIR, PATCH AND MATCH ALL EXISTING CONSTRUCTION AND
FINISHES OF ALL FLOORS WALLS AND CEILINGS. WHERE CONCRETE MASONRY CONSTRUCTION IS MODIFIED, THE
CONTRACTOR SHALL TOOTH IN ALL NEW CONSTRUCTION TO MATCH THE EXISTING BOND. WHERE CONCRETE
CONSTRUCTION IS MODIFIED, THE CONTRACTOR SHALL VERIFY THE EXACT DETAILS TO BE USED FOR
CONSTRUCTION. ALL WORK SHALL BE COVERED UNDER THE GENERAL CONTRACT,
14. IF CONTRACTOR OR SUBCONTRACTOR FIND IT NECESSARY TO DEVIATE FROM ORIGINAL APPROVED PLANS, THEN
IT IS THE CONTRACTOR'S AND THE SUBCONTRACTOR'S RESPONSIBILITY TO PROVIDE THE CONSULTANT WITH 4
COPIES OF THE PROPOSED CHANGES FOR HIS APPROVAL BEFORE PROCEEDING WITH THE WORK, IN ADDITION THE
CONTRACTOR AND SUBCONTRACTORS SHALL BE RESPONSIBLE FOR PROCURING ALL NECESSARY APPROVALS FROM
THE BUILDING AUTHORITIES FOR THE PROPOSED CHANGES BEFORE PROCEEDING WITH THE WORK. THE
CONTRACTOR AND SUBCONTRACTORS SHALL BE RESPONSIBLE FOR PROCURING ALL NECESSARY INSPECTIONS AND
APPROVALS FROM BUILDING AUTHORITIES DURING THE EXECUTION OF THE WORK.
15. CONTRACTOR TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2 -A OR 2 A OBC
WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF PROJECT AREA DURING CONSTRUCTION,
16. THE CONTRACTOR SHALL PERFORM WORK DURING OWNER'S PREFERRED HOURS TO AVOID DISTURBING NORMAL
BUSINESS.
17. SEAL ALL PENETRATIONS THROUGH FIRE -RATED AREAS WITH U.L. LISTED OR FIRE MARSHAL APPROVED
MATERIALS AS APPLICABLE TO THIS FACILITY AND OR PROJECT SITE
18. CONTRACTOR SHALL BE RESPONSIBLE FOR UTILITY LOCATES, SCHEDULING COORDINATING SPECIAL AND
BUILDING DEPARTMENT INSPECTIONS.
19. CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING AND UTILIZING ORIGINAL ROOFING CONTRACTOR AS
REQUIRED TO MAINTAIN ANY EXISTING ROOFING WARRANTY,
20. ROUTING OF ALL CONDUITS, CABLES, CABLE TRAYS ETC ARE INDICATED AS PROPOSED LOCATION ONLY
CONFIRM THE EXACT LOCATION AND ROUTING WITH THE ON SITE T- MOBILE CONSTRUCTION MANAGER PRIOR TO
STARTING WORK.
CONCRETE NOTES:
1, ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE ACI 301, ACI 318 AND THE SPECIFICATION
CAST -IN -PLACE CONCRETE.
2. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS UNO.
3. REINFORCING STEEL SHALL CONFORM TO ASTM A 615. GRADE 60, DEFORMED UNLESS NOTED OTHERWISE.
WELDED WIRE FABRIC SHALL CONFORM TO ASTM A 185 WELDED STEEL WIRE FABRIC UNLESS NOTED OTHERWISE.
SPLICES CLASS "B" AND ALL HOOKS SHALL BE STANDARD UNO.
4. THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCING STEEL UNLESS SHOWN
OTHERWISE ON DRAWINGS: CONCRETE CAST AGAINST EARTH -3IN. CONCRETE EXPOSED TO EARTH OR WEATHER:
#6 AND LARGER ......................2 IN.
#5 AND SMALLER & WWF.._.....11 /2IN.
5. A 1/2" TROWELED RADIUS SHALL BE PROVIDED AT ALL EXPOSED EDGES OF CONCRETE UNO. HOLES TO RECEIVE
EXPANSION/WEDGE ANCHORS SHALL BE 1/8" LARGER IN DIAMETER THAN THE ANCHOR BOLT, DOWEL OR ROD AND
SHALL CONFORM TO MFR RECOMMENDATION FOR EMBEDMENT DEPTH OR AS SHOWN ON THE DRAWINGS. AVOID
CUTTINGEXISTING REBAR WHEN DRILLING HOLES IN THE ELEVATEDSLAB,
6. INSTALLATION OF CONCRETE EXPANSION/NIEDGE ANCHOR SHALL BE PER MANUFACTURERS WRITTEN
RECOMMENDED PROCEDURES,
7. FLOAT SURFACE SHALL BE A SMOOTH FINISH, SURFACE SHALL BE FREE OF ALL OBVIOUS DEPRESSIONS, SURFACE
SHALL BE SLOPED AT 2 TO PROMOTE DRAINAGE AWAY FROM EQUIPMENT,
SITE WORK NOTES:
1. RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND
DISPOSED OF LEGALLY.
2. THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE PCS EQUIPMENT, TOWER
AREAS. ANDADJACENT BUILDINGS.
3. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUND. FROZEN MATERIALS, SNOW OR ICE
SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT,
4. THE SUBGRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRADE PRIOR TO THE CRUSHED
STONE APPLICATION.
5, ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES WHERE ENCOUNTERED IN THE WORK.
SHALL BE PROTECTED AT ALL TIMES, AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE
RELOCATEDAS DIRECTED BY ENGINEERS. EXTREME CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN
EXCAVATING OR PIER DRILLING AROUND OR NEAR UTILITIES. CONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR
THE WORKING CREW.
6. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHICH INTERFERE WITH THE
EXECUTION OF THE WORK, SHALL BE REMOVED AND SHALL BE CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT
POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL OF
ENGINEERING,
7. THE AREAS OF THE CUSTOMER'S PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THE BUILDING,
DRIVEWAY OR CRUSHED STONE, SHALL BE GRADED TO A UNIFORM SLOPE, FERTILIZED, SEEDED, AND COVERED WITH
MULCH AS SPECIFIED IN THE SPECIFICATION LANDSCAPE WORK.
8, BEDDING MATERIAL FOR UTILITY LINES, CULVERTS AND PIPING: CLEAN SAND, MEDIUM TP COARSE, SUB ROUNDED
NATURAL RIVER OR BANK SAND, WASHED, FREE OF SILT OR CLAY, LOAM, FRIABLE OR SOLUBLE MATERIALS, AND
ORGANIC MATER: GRADED IN ACCORDANCE WITH THE FOLLOWING GRAIN SIZE DISTRIBUTION:
SIEVE SIZE
PERCENT PASSING
3/8"
100
NO 4 MESH
60 -90
NO. 8 MESH
045
NO. 16 MESH
0 -25
NO. 100 MESH
0 -2
NO. 200 MESH
0 -2
9. DIMES FOR TEMPORARY EROSION /SEDIMENTATION CONTROL SHALL BE IMPLEMENTED PER LOCAL, CITY OR
COUNTY GUIDELINES AND PER PLAN IF APPLICABLE.
ABBREVIATIONS
AC
AIR CONDITIONER
JT
JOINT
AFF
ABOVE FINISHED FLOOR
LAM
LAMINATED
ADO
ABOVE FINISHED GRADE
LF
LINEAL FOOT
AFS
ABOVE FINISHED SLAB
MANUF
MANUFACTURER
ALUM
ALUMINUM
MAX
MAXIMUM
AS
ANCHOR DOLT
MECH
MECHANICAL
L
ANGLE
MH
MANHOLE
ARCH
ARCHITECTURAL
MM
MILLIMETER
BTS
BASE TRANSMISSION SYSTEM
MIN
MINIMUM
BLDG
BUILDING
MISC
MISCELLANEOUS
BM
BEAM
MPH
MILES PER HOUR
ROT
BOTTOM
MTL
METAL
B.O.
BOTTOM OF
NO
NOT IN CONTRACT
BOC
BOTTOM OF CONCRETE
NOM
NOMINAL
BOB
BOTTOM OF STEEL
NTS
NOT TO SCALE
CJ
CONTROL JOINT
OC
ON CENTER
CENTERLINE
OR
OUTSIDE DIAMETER
CLG
CEILING
OH
OVERHEAD
CLR
CLEAR
OPNG
OPENING
CMU
CONCRETE MASONRY UNIT
OPP
OPPOSITE
COL
COLUMN
(P)
PROPOSED
ONC
CONCRETE
PCS
PERSONAL COMMUNICATION CATION SYSTEM
CONST
CONSTRUCTION
R
PLATE
C
CONTINUOUS
PR
PAIR
TR
CENTER
PSI
POUNDS PER SQUARE INCH
DIA
DIA /0
DIAMETER
PSF
POUNDS PER SQUARE FOOT
DTL
DETAIL
PT
PRESSURE TREATED
(E)
EXISTING
PAD
RADIUS
EA
EACH
RD
ROOF DRAIN
EJ
EXPANSION JOINT
REINF
REINFORCED /REINFORCING
ELEC
ELECTRIC /ELECTRICAL
REQ'D
REQUIRED
EL
ELEVATION
RM
ROOM
ED
EQUAL
R/W
RIGHT OF WAY
EW
EACH WAY
SCHED
SCHEDULE
EXP
EXPANSION
SECT
SECTION
EXT
EXTERIOR
SF
SQUAREFOOT
FD
FLOOR DRAIN
SIM
SIMILAR
FIN
FINISH
SO FT
SQUARE FOOT
FIN FLR
FINISH FLOOR
SS
STAINLESS STEEL
FUR
FLOOR
STD
STANDARD
PTO
FOOTING
STL
STEEL
GA
GAUGE
STRUC
STRUCTURAL
GALV
GALVANIZED
TEMP
TEMPORARY
GYP
GYPSUM
THK
THICK
GB
GYPSUM BOARD
T.O.
TOP OF
HM
HOLLOW METAL
TOS
TOP OF STEEL
TOR
HORIZONTAL
TOO
TOP OF CONCRETE
HR
HOUR
TYR
TYPICAL
HT
HEIGHT
UNO
UNLESS NOTED OTHERWISE
HVAC
HEATING VENTILATION AIR CONDITIONING
VCT
VINYL COMPOSITION TILE
INSUL
INSULATION
VERT
VERTICAL
INT
INTERIOR
W/
WITH
WWM
WELDED WIRE MESH
LEGENDS & SYMBOL$
CHAINLINK FENCE X X= X X X X
CEDAR FENCE
POWER P P P P P P
TELCO
T-
T -- T- T- T-
T
POWER/TELCO
T= P T P
T
P-
COAX
COAX
(COAX COAX -
COAX
OVERHEAD POWER
O/H
O /IH - O/H - O/H
O/H
CENTERLINE
511512013
REV. PER
REVISION BUG
DETAIL NUMBER
ELEVATION VIEW BUG
SHEET NUMBER
TOP ELEVATION O F
EL 0' -0"
DETAIL NUMBER
DETAIL BUG - SHEET NUMBER
SECTION BUG
DETAIL NUMBER
SHEET NUMBER
T • •Mobile•
= PROJECT INFORMATION:
WILKENSON
ROAD /RAILWAY
SE05198D
16220 RAILWAY ROAD SE
YELM, WA 98597
BUILDING PERMIT
C
REVISION HISTORY:
NO. DATE: DESC
=PLANS PREPARED B',:
B. J. THOMAS, P.E.
7607 80TH AVE HE
MARYSVILLE, WA 98270
206 - 851.1106
=DRAWN BY: CHK. BY: =APPV. BY::
AAL BJ KC
NEW RADIO EQUIPMENT & NEW ANTENNAS.
= DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF
DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR
DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED
CLIENT IS STRICTLY PROHIBITED.
TITLE:
GENERAL NOTES
NUMBER:
G -1
3
1/1512014
UPDATE CC
PROJECTTE
511512013
REV. PER
4/25/2013
ISSUED DE
=PLANS PREPARED B',:
B. J. THOMAS, P.E.
7607 80TH AVE HE
MARYSVILLE, WA 98270
206 - 851.1106
=DRAWN BY: CHK. BY: =APPV. BY::
AAL BJ KC
NEW RADIO EQUIPMENT & NEW ANTENNAS.
= DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF
DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR
DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED
CLIENT IS STRICTLY PROHIBITED.
TITLE:
GENERAL NOTES
NUMBER:
G -1
\
64300800100
i PGj / \
/ \
i Pe
I e�
\ 64300700501
(E) RAIL ROAD TRACKS // \
/ \22719311100
64300700500 \
Z \ \
(E) CHAIN LINK FENCE COMPOUND
/
I /
/
# \
W /(E)STEEL MONOPOLE AND T-MOBI ENLARG DSIT PLAN) ## \ \
I / / (SEE SHT. A -1.1 FOR ENLARGED SITE PLAN) \
I c
V /
I \ \
, o
64300700600
#
o /
o # ,
PROPERTY LINE \ /
—� — — 6430'0600407
#
RAILWAY RD SE - —
I \
I ,
I \
� I
�I I
/ V A
\ I \
OVERALL SITE PLAN /
22.34 SCALE: 1" = 100'
N Ilxl7SCALE 1" = 200'
ioo o so' ioo 20a
\
T • •Mobile•
= PROJECT INFORMATION:
WILKENSON
ROAD /RAILWAY
SEOS198D
16220 RAILWAY ROAD SE
YELM, WA 98597
= ISSUED FOR:
BUILDING PERMIT
= REVISION HISTORY:
NO. DATE: DESCRIPTION: CHK. APPV.
BY: BY:
=PLANS PREPARED BY:
B. J. THOMAS, P.E.
7607 80TH AVE NE
MARYSVILLE, WA 98270
206.851.1106
=DRAWN BY: CHK. BY: =APPV. BY:-
AAL BJ KC
0
11 0
=EQUIPMENT:
NEW RADIO EQUIPMENT & NEW ANTENNAS.
= DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF
DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR
DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED
CLIENT IS STRICTLY PROHIBITED.
SITE PLAN
N
a -1 J
3
1/15/2014
UPDATE CODE COMPLIANCE &
PROJECTTEAM
BUT
Al
5/15/2013
REV. PER REDLINES
BJT
]KC
4/25/2013
ISSUED DESIGN REVIEW
BJT
=PLANS PREPARED BY:
B. J. THOMAS, P.E.
7607 80TH AVE NE
MARYSVILLE, WA 98270
206.851.1106
=DRAWN BY: CHK. BY: =APPV. BY:-
AAL BJ KC
0
11 0
=EQUIPMENT:
NEW RADIO EQUIPMENT & NEW ANTENNAS.
= DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF
DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR
DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED
CLIENT IS STRICTLY PROHIBITED.
SITE PLAN
N
a -1 J
(P) (2) DIPLEXERS & (E) (2) DUAL BAND TMA
MOUNT TO (E) PIPE BEHIND (E) ANTENNA
(CAP OFF PCS SIDE & REUSE AWS SIDE OF (E) TMA)
(P) (1) FRIG MOUNT TO (E) PIPE BEHIND (P)
\t
(E) T- MOBILE DUAL ANTENNA TO BE REPLACED
W/ (P) (1) TMBXX- 6516 -R2M ANTENNA
GAMMASECTOR', 240'AZIMUTH
N
(E) (1) TMBXX -6516 -R2M TO REMAIN MOUNT TO (E) PIPE?
GAMMA SECTOR: 240' AZIMUTFF
(P) (2) DIPLEXERS & (E) (:2) DUAL BAND TMA
MOUNT TO (E) PIPE BE (E) ANTENNA
(CAP OFF LOS SIDE & REUSE AWS SIDE OF (E) TMA)
(P) (1) FRIG MOUNT TO (E�) PIPE BEHIND (P)
(E) T- MOBILE DUAL ANTENNATO BE REPLACED
VW (P (1) TMBXX - 6516 -R2M ANTENNA
BETA SECTOR: 120 - AZIMUTH
+
+
ENLARGED SITE PLAN
22x34 SCALE: 3 /116^ =1
11x17 SCALE'. 3/3:2^ = 1'
(E) (1) TMBXX- 6516 -R2M TO REMAIN MOUNT TO (E) PIPE
ALPHASECTOR. 35`AZIMUTH
(P) (2) FXFB & (P) (1) COVE
ON 2 -3/8" 0 PIPES MOUNT TO (E) POLE
W /8" STANDOFF (VALMONT #MM01)
& UNIVERSAL RING MOUNT (VALMONT #801068)
BELOW (E) T- MOBILE ANTENNA PAR CENTER
(E) T- MOBILE DUAL ANTENNA TO BE REPLACED
W/ (P) (1) TMBXX- 6516 -R2M ANTENNA
ALPHA SECTOR. 35" AZIMUTH
(1) FRIG MOUNT TO (E) PIPE BEHIND (P) ANTENNA
(P) (2) DIPLEXERS & (E) (2) DUAL BAND TMA
MOUNT TO (E) PIPE BEHIND (E) ANTENNA
(CAP OFF PCS SIDE & REUSE AWS SIDE OF (E) TMA)
(E) (1) TMBXX- 6516 -R2M TO REMAIN MOUNTTO (E) PIPE
BETA SECTOR: 120 AZIMUTH
(P) (1) HYBRID CABLE (175 LF.)
ROUTE Wl (E) (I Z) 718" COAX FEEDERS
COVE MOUNT TO (E) BTS CABINET
(E) PROPANE TANK
CHAIN LINK FENCE COMPOUND
DC POWER CABLE ROUTED IN EMT dR LT
EX FROM (E) PURCELLTO (P) COVP
EQUIPMENT ON (E) H -FRAME
EQUIPMENT ON (E) H -FRAME
T • •Mobile•
= PROJECT INFORMATION:
WILKENSON
ROAD /RAILWAY
SE05198D
16220 RAILWAY ROAD SE
YELM, WA 98597
BUILDING PERMIT
= REVISION HISTORY:
NO. DATE: DESCRIPTION: CHK. APPV.
BY: BY:
=PLANS PREPARED BY:
B. J. THOMAS, P.E.
7607 80TH AVE NE
MARYSVILLE, WA 98270
206- 851 -1106
=DRAWN BY: CHK. BY: =APPV. BY::
AAL BJ KC
RE:
NEW RADIO EQUIPMENT & NEW ANTENNAS.
= DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF
DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR
DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED
CLIENT IS STRICTLY PROHIBITED.
TITLE:
ENLARGED
SITE PLAN
NUMBER:
Aml A
3
1/15/2014
UPDATE CODE COMPLIANCE&
PROJECT TEAM
BJT
Al
A5/15/2013
REV. PER REDLINES
BUT
KC
4/2572013
ISSUED DESIGN REVIEW
BJT
KC
=PLANS PREPARED BY:
B. J. THOMAS, P.E.
7607 80TH AVE NE
MARYSVILLE, WA 98270
206- 851 -1106
=DRAWN BY: CHK. BY: =APPV. BY::
AAL BJ KC
RE:
NEW RADIO EQUIPMENT & NEW ANTENNAS.
= DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF
DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR
DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED
CLIENT IS STRICTLY PROHIBITED.
TITLE:
ENLARGED
SITE PLAN
NUMBER:
Aml A
(E) (3) T- MOBILE QUAD ANTENNAS
TOP OF STEEL MONOPOLE
150' 0" AGL
T- MOBILE RAD CENTER
147' 9" ACT
(E) (3) T- MOBILE DUAL ANTENNAS +�
III III;
III.
l
VIII
(E) (6) DUAL BAND TMA (2 PER SECTOR) j
I
MOUNT TO (E) PIPE BEHIND ANTENNAS III II
I fill
Ii;ll
�lll
I',11
�IiI1'
I
(E) 1 W' AGLSTEEL MONOPOLE
I !.III
ICI II'.
Ilj�'I
IIIi11
�l ,lil
�IIII
I
I�IIIII 4-
I�1
Hi1ll l �
� r
"(rI
ry wv MIDI_/ j 1I �I
I
_rn
� �_�_L' AAA � • -'\V�'�iv'r�
,y r rEI +SY
(\ P1 W4 '` � 1 �L C� i (✓<�` t ELI /� � (�\ i , �
y.�i AIA �I " <�(�rl� +�:v I' •, I`�= ter'
11,( C �f L `'�` �� (E) (1z) 7!a" coAx FEEDERS - 1 , ' ..
�� �� Ii��')�� -n`•4 VA d� 'L r <(\ ROUTE WITHIN (E) STEEL MONOPOLE +fl 2 \`
y
»�
g
_� � V� }• �� I�u �i {u`>. i��
/ O ( 1
�f�iTJ .v F�`ld
✓ /\ A IGIi %ICI v r�s �1�= r_!I i
iY II�R 1
/ it
r <&d4�
lU
io
ytl� 1 " (1 11
G III . A v 1
tt,3Py 14 V �C�A� IY.
.Ib,.�, :�y r ��%!i y '< *1 ,y �Jr1 ! \ III / 1 •d / �\
9�iLt' ' t�4itt. . %� /
11 rllq
��{Yp/,��!i '7L
' �..L`CN�,I ri•�.P; / /,, �` I4.� ;c.
/,A
C ` g at1 8r
<
/
T
tx �i{ � � r r rL'%lE CHAIN LINK FENCE COMPOUND� ` T % < •��- \ T'1 ) yn �� ri nQ I�I > > -"?r/ � yy �--•� "_�}.. �h �. -.. WIT - MOBILE EQUIPMENT WITHIN I[, PII, , / v y�Ir.Tn ,11\ib<
r�A>S SRj4-r c; -+ r \11 / /i� F r III ,1` =\ n \I\ \\ Q,?f.,'r }�.., }r.�YvA x��r111\4LJ \�1 Flri�� 'i rlr !I,- �\ 1�i <.%rl i; t� %k ti ✓,.
7ydn' +Hfv . . 1v y /.% .. 1 ` 1 �I �� ��. n II u c a,
k`i✓ ����yw' / A/ / ill ��
p <y ✓ / A './ 7 a 1.
.'
�.Ta `Yy4
%.p�r,�xrnt`�j
1�
C
PAS
1 EXISTING SOUTH ELEVATION
A -21 22x34 SCALE: 1/8" = 1'
11x17 SCALE: 111, = 1'
Tom • •Mobile•
= PROJECT INFORMATION:
WILKENSON
ROAD /RAILWAY
SE05198D
16220 RAILWAY ROAD SE
YELM, WA 98597
= ISSUED FOR:
BUILDING PERMIT
= REVISION HISTORY:
NO. DATE: DESC
=PLANS PREPARED BT:
B. J. THOMAS, P.E.
7607 80TH AVE NE
MARYSVILLE, WA 98270
206 - 851.1106
=DRAWN BY: CHK. BY: =APPV. BY:=
AAL BJ :KC]
= LICENSURE:
=EQUIPMENT:
NEW RADIO EQUIPMENT & NEW ANTENNAS.
= DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF
DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR
DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED
CLIENT IS STRICTLY PROHIBITED.
EXISTING
SITE ELEVATION
NUMBER:
A -2
3
1/152014
UPDATE CO
PROJECTT[
A2
REV. PER
4125/2013
ISSUED DI
=PLANS PREPARED BT:
B. J. THOMAS, P.E.
7607 80TH AVE NE
MARYSVILLE, WA 98270
206 - 851.1106
=DRAWN BY: CHK. BY: =APPV. BY:=
AAL BJ :KC]
= LICENSURE:
=EQUIPMENT:
NEW RADIO EQUIPMENT & NEW ANTENNAS.
= DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF
DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR
DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED
CLIENT IS STRICTLY PROHIBITED.
EXISTING
SITE ELEVATION
NUMBER:
A -2
1 ENLARGED DETAILS
A -2.1 22x34 SCALE: 1/2" = 1'
11x17 SCALE: V4'- V
DUAL BAND TMA (2 PER SECTOR)
DEF PCS SIDE & REUSE AWS SIDE OF (E) TMA)
(E) (3) TMBXX5516 -R2M (1 PER SECTOR)
TO REMAIN MOUNT TO (E) PIPES
(E) (3) T- MOBILE DUAL ANTENNAS TO BE REPLACED
W/ (P) (3) TMBXX- 6516-R2M ANTENNA (1 PER SECTOR)
(P) (5) DIPLEXERS (2 PER SECTOR),
(E) (6) DUAL BAND TMA (2 PER SECTOR),
& (P) (3) FRIG (1 PER SECTOR)
MOUNT TO (E) PIPE BEHIND ANTENNAS
(CAP OFF PCS SIDE & REUSE AWS SIDE OF (E) TMA)
1
ii
T( 0
'
i /
u,�G� X�/
���
-1
J
S t_
To �-
TOP OF STEEL MONOPOLE
u0' -0" AGL
T- MOBILE HAD CENTER
147' -9" AGL
NOTE.
ALL NEW ANTENNAS, RADIO UNITS, AND EQUIPMENT PAINT TO
MATCH EXISTING ANTENNAS AND EQUIPMENT.
150' AGL STEEL MONOPOLE
(P) (1) HYBRID CABLE (175 LF.)
& (E) (12) 718" COAX FEEDERS
ROUTE WITHIN (E) STEEL MONOPOLE
(E) CHAIN LINK FENCE COMPOUND
WIT-MOBILE EQUIPMENT WITHIN
2 PROPOSED SOUTH ELEVATION
A -2.1 22x34 SCALE: 1/8" = 1'
11x17 SCALE: 1/15' = 1'
T • •Mobile•
= PROJECT INFORMATION:
WILKENSON
ROAD /RAILWAY
SE05198D
16220 RAILWAY ROAD SE
YELM, WA 98597
= ISSUED FOR:
BUILDING PERMIT
= REVISION HISTORY:
NO. DATE: DESCRIPTION: CHK. APPV.
BY:
3 BY-
�.i4a r
1
ii
T( 0
'
i /
u,�G� X�/
���
-1
J
S t_
To �-
TOP OF STEEL MONOPOLE
u0' -0" AGL
T- MOBILE HAD CENTER
147' -9" AGL
NOTE.
ALL NEW ANTENNAS, RADIO UNITS, AND EQUIPMENT PAINT TO
MATCH EXISTING ANTENNAS AND EQUIPMENT.
150' AGL STEEL MONOPOLE
(P) (1) HYBRID CABLE (175 LF.)
& (E) (12) 718" COAX FEEDERS
ROUTE WITHIN (E) STEEL MONOPOLE
(E) CHAIN LINK FENCE COMPOUND
WIT-MOBILE EQUIPMENT WITHIN
2 PROPOSED SOUTH ELEVATION
A -2.1 22x34 SCALE: 1/8" = 1'
11x17 SCALE: 1/15' = 1'
T • •Mobile•
= PROJECT INFORMATION:
WILKENSON
ROAD /RAILWAY
SE05198D
16220 RAILWAY ROAD SE
YELM, WA 98597
= ISSUED FOR:
BUILDING PERMIT
= REVISION HISTORY:
NO. DATE: DESCRIPTION: CHK. APPV.
BY:
3 BY-
=PLANS PREPARED BY:
B. J. THOMAS, P.E.
7607 80TH AVE NE
MARYSVILLE, WA 98270
206. 851.1106
=DRAWN BY: CHK. BY: —APPV. BY:-
AAL BJ KC
= EQUIPMENT:
NEW RADIO EQUIPMENT &NEW ANTENNAS.
= DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF
DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR
DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED
CLIENT IS STRICTLY PROHIBITED.
NG TITLE:
PROPOSED
SITE ELEVATION
NUMBER:
Am2m I �
1/152014 4
UPDATE CODE COMPLIANCE&
PROJECTTEAM
gJT
Al
A5/15/2013
REV. PER REDLINES
BUT
KC
4/25/2013
ISSUED DESIGN REVIEW
BJT
KC
=PLANS PREPARED BY:
B. J. THOMAS, P.E.
7607 80TH AVE NE
MARYSVILLE, WA 98270
206. 851.1106
=DRAWN BY: CHK. BY: —APPV. BY:-
AAL BJ KC
= EQUIPMENT:
NEW RADIO EQUIPMENT &NEW ANTENNAS.
= DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF
DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR
DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED
CLIENT IS STRICTLY PROHIBITED.
NG TITLE:
PROPOSED
SITE ELEVATION
NUMBER:
Am2m I �
1.
MAIN GROUND 21014 F
RETURN 15 CONNE
2/0-
GROUND BAR 4 -14
7.6° NOKIA FXFB MODEL #472166A
RET
ANT 6 ANT 4 ANT 2 (FXFB ONLY) PROPERTY VALUE
RX ANT 5 RX ANT 3 RX ANT 1 HEIGHT 133mm13U
WR IN Rx06 TX/RX RxO4 TX/RX RxO2 TX/RX (5.2 in)
RxO 5 RxC 3 RxO 1 WIDTH 447 mm
o WIDTH (WITH (17,6in) m
COVERS) 490 m
o o�o o�o (19.3in)
O O o o O o 0 o O o 0 0• a O DEPTH (FOR RACK 395 mm
ASSEMBLIES) (15.6 in)
CD 0 5.2" DEPTH (WITH 560 mm
VKIN O O ° ° Q O O O COVERS) (22 in)
ao
0
R & FIBER JUMPER OUT WEIGHT
(INCLUDING THE MAX, 25 kg
p CORE. FANS AND (55.1IR
LED FAN/TX GROUNDING CASING)
OFF STATUS POINTS OPT
LEDMODULE
STATUS EAC OPT 1 OPT 3
2 FXFB DETAIL
A -3 SCALE: NTS
FRONT RIGHT SIDE BOTTOM
1 RAYCAP COVP DETAIL
A -3 SCALE: NTS
3 COVP INTERIOR DETAIL
A -3 SCALE: NTS
PANEL 18 SM ADAPERS
�;ONN ECTIONS ZO - 14 AWG
HYBRID CABLE
STRUCTURE
LENGTH
DEPTH
COOF
MONOPOLE
1 175'
RIGHT SIDE
6 HYBRID CABLE DETAIL
A -3 SCALE: NTS
COVP MOUNT'"'^ -i "'
114 "0 GALV
(TYP OF 8 PE
MOUNTING BI
� PIPE
3/8 "0 GALV U -I
1/4 "0 GALV BC
(TYP OF 4 PER C
C ..
�4:) COW MOUNTING DETAIL
A -3 SCALE: NTS
RIGHT SIDE
NOKIA FRIA
5.2"
MODULE
WIDTH
HEIGHT
DEPTH
WEIGHT
24.0 kg 125.9 Ibs
SOLAR SHIELD WEIGHT
1.2 kg 12.6lbs
22.1" (WITH COVER)
0.7 kg / 1.5 lbs
SYSTEM TOM
17.6"
5.2"
16.6 "(WITHOUT COVER)
463 LBS
3
1/15/2014
UPDATE CO
PROJECT TE
22,1" (WITH COVER)
RADIO FRxx
17.6"
8.2"
16.6" (WITHOUT COVER)
46.3 LBS
22.1" (WITH COVER)
AC POWER FPMA
*HERA
1,8"
5.2"
16.6 "(WITHOUT COVER)
24.3"
2.8"
3.9"
15,.
7.0"
*FPBA
2.8"
3.9"
15„
8.4"
SITE SUPPORT FCSA
26.3"
14.4"
20.6"
44.1 LBS
*LTE
17,6"
7"
171"
*MIBBU (WPU)
17.6"
5.2"
-
44.1 LBS
*WMP
43"
1.3"
-
6.2 LBS
5 FRIA DETAIL
A-3 SCALE NTS
DIMENSIONS (WxHxD) W/
SOLAR COVER & MOUNTING
17 2" x 23.8" x 7.5"
FRIG UNIT WEIGHT
24.0 kg 125.9 Ibs
SOLAR SHIELD WEIGHT
1.2 kg 12.6lbs
MOUNTING
0.7 kg / 1.5 lbs
BRACKET WEIGHT
TOTAL WEIGHT
25.9 kg 157 Ins
23.8"
17.2"
GPnNT
8 FRIG DETAIL
A-3 SCALE: NTS
NOTE:
FRIG TO BE MOUNTED
VERTICALLY ONLY
7.5
RIGHT SIDE
T • •Mobile•
= PROJECT INFORMATION:
WILKENSON
ROAD /RAILWAY
SEOS198D
16220 RAILWAY ROAD SE
YELM, WA 98597
ISSUED FOR:
fBUILDING PERMIT
= REVISION HISTORY:
NO. DATE: DESC
=PLANS PREPARED B'r:
B. J. THOMAS, P.E.
7607 80TH AVE NE
MARYSVILLE, WA 98270
206 - 851.1106
=DRAWN BY: CHK. BY: =APPV. BY:-
AAL BJ KC
RE:
NEW RADIO EQUIPMENT &NEW ANTENNAS.
= DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF
DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR
DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED
CLIENT IS STRICTLY PROHIBITED.
GENERAL DETAILS
NG N
A -3
3
1/15/2014
UPDATE CO
PROJECT TE
A5/15/2013
REV. PER
412512013
ISSUED DE
=PLANS PREPARED B'r:
B. J. THOMAS, P.E.
7607 80TH AVE NE
MARYSVILLE, WA 98270
206 - 851.1106
=DRAWN BY: CHK. BY: =APPV. BY:-
AAL BJ KC
RE:
NEW RADIO EQUIPMENT &NEW ANTENNAS.
= DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF
DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR
DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED
CLIENT IS STRICTLY PROHIBITED.
GENERAL DETAILS
NG N
A -3
PARTS LIST
ITEM #
QuANnTV
PART NUMBER
DESCRIPTION
1
2
601257
ANGLEARM
2
2
601256
110I11471NG CLAMP
3
2
601235.1
BRACKET
4
2
601235 -2
BRAC4E0=T
5
1
801256
IABI
8
4
800679:1
SPADERTUBE
7
14
10052524
ME FLAT WASMR(SfA09LES3 STEEL)
8
2
SOM792
M&d.25x2&w LARGE CARRROE BOLT(STA99M SfEEL)
9
8
SM17385
258 LOCK WASHER (sTmLE33 STEEL)
10
4
600419 -10
M6x1.25010m LARGE HEI MAD SCREW(S7NNUMS WEI
11
8
204001 -15
M80.25HEXNU7(S7NNLESSSIEEL)
12
2
225244
CLAMP PLATE
13
6
800419.24
LARGE LOCK WASHER (STAINLESS STEEL
14
8
204001 -21
11112,1.75 HE)( NV7(STAINLESS STEEL)
15
4
800419.12
1112x1.79xl50mm LARGE CARRAGE BOLT(STAINlESS STEEL)
17
1
601564
MOLYBDENUM D=LFIOE GREASE
BOTTOM
BRACKET
11 9 7
TOP
BRACKET
NNA BRACKET ATTACHMENT DETAIL
SCALE:NTS
SIDE TOP
4 FMFA DETAIL
q-q SCALE: NTS
CATION FOR OF 2)
MOUNT LOCATION (fYR OF 2)
MOUNT LOCATION (TYP OF 5)
3" STD
�<Z>
ANTENNA
2 ANTENNA ATTACHMENT WTA1L
Ad SCALE:NTS
MOUNTING BRACKET
/ M8xl 20 BOLT
<
ZOO
72"
BOLT
FMFA FIXING POINTS
&F7K� DETAIL
S
ia
UNIVERSAL RING (MOUNT & 8" STANDOFF DETAIL
SCALE: NTS
6 RRU MOUNTING DETAIL
q -q SCALE: NTS
4TH
RF MODULE
T • •Mobile•
WILKENSON
ROAD /RAILWAY
SE05198 D
16220 RAILWAY ROAD SE
YELM, WA 98597
= ISSUED FOR:
BUILDING PERMIT
= REVISION HISTORY:
NO. DATE: DESCRIPTION: CHK. APPV.
BY: BY:
=PLANS PREPARED BY:
B. J. THOMAS, P.E.
7607 80TH AVE NE
MARYSVILLE, WA 98270
206.851.1106
=DRAWN BY: CHK. BY: =APPV. BY::
AAL BJ KC
=LICENSURE:
=EQUIPMENT.
NEW RADIO EQUIPMENT & NEW ANTENNAS.
= DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF
DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR
DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED
CLIENT IS STRICTLY PROHIBITED.
NG TITLE:
GENERAL DETAILS
NUMBER:
A -4
3
1115/2014
UPDATE CODE COMPLIANCE&
PROJECTTEAM
BJT
Al
A5/1512013
REV. PER REDLINES
BJT
KC
ZL
4/25/2013
ISSUED DESIGN REVIEW
BJT
KC
=PLANS PREPARED BY:
B. J. THOMAS, P.E.
7607 80TH AVE NE
MARYSVILLE, WA 98270
206.851.1106
=DRAWN BY: CHK. BY: =APPV. BY::
AAL BJ KC
=LICENSURE:
=EQUIPMENT.
NEW RADIO EQUIPMENT & NEW ANTENNAS.
= DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF
DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR
DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED
CLIENT IS STRICTLY PROHIBITED.
NG TITLE:
GENERAL DETAILS
NUMBER:
A -4
(P) MECHANICAL CONNECTION (T
(SEE GROUNDING NOTES 94 8
BOND (P) ANTENNAS & (P) RRU EQUIPMENT TO
(E) AGB NEAR (E) T -MOBI
SYMBOL LEGEND:
MGB
7r MASTER GROUND BAR 1/4 "x4 "x24" COPPER
AGB
ACCESSORY GROUND BAR 114 "x4 "x12" OR
114 "xTN20" COPPER
EXPOSED WIRING
UNDERGROUND WIRING
CADWELD
• MECHANICAL CONNECTION
• 5/8 "x8' COPPER CLAD STEEL GROUND ROD
OINSPECTION PORT
--E-- EXOTHERMIC (CADWELD) BELOW GROUND
L GROUND
GROUNDING NOTES:
1. GROUNDING SHALL COMPLN' WITH LATEST EDITION OF THE NATIONAL ELECTRICAL CODE.
2. MINIMUM BENDING RADIUS IFOR GROUND CONDUCTOR IS 811
.
3. NO SPLICES PERMITTED IN (GROUND CONDUCTORS.
4. ALL GROUNDING CONNECTORS TO BE CLEAN AND FREE OF PAINT AT THEIR MATING
SURFACES AND INSTALLED PER MANUFACTURER'S RECOMMENDATIONS_ USE PENETROX
OR EQUIVALENT ANTIOXIDANT GREASE.
5. ALL GROUND BAR CONNECT IONS ARE TO BE 2 HOLE LUG COMPRESSION TYPE. STACKED
CONNECTIONS ARE NOT ACCEPTABLE. BACK TO BACK CONNECTIONS ON OPPOSITE SIDES
OF THE GROUND BAR WILL BE PERMITTED.
6. ENSURE ALL MECHANICAL CONNECTORS ARE TORQUED TO THE MANUFACTURER'S
SPECIFIED VALUES.
7. MULTIPLE BONDS ON GROUND RODS TO BE SEPARATED BY ATLEAST 6"
8. MAXIMUM RESISTANCE OF THE COMPLETED GROUND SYSTEM SHALL NOT EXCEED A
RESISTANCE OF 5 OHMS TO EARTH.
9. GROUND WIRES SHALL NOT BE INSTALLED THROUGH HOLES IN ANY METAL OBJECTS OR
SUPPORTS, TO PRECLUDE CSTABLISHING A "CHOKE" POINT.
10. GROUND BARS SHALL NOT BE FIELD MODIFIED.
11, GROUND RING BURIAL DEPTH SHALL BE 30
12. A CERTI Fl ED CONTRACTOR\RILL MAKE ALL MEASUREMENTS REQUI RED TO TEST THE
GROUNDING SYSTEM USING A MEGGER OR EQUIVALENT. THE ACCEPTABLE RESISTANCE
MEASURED FOR THE GROUNDING SYSTEM WILL NOT EXCEED 5 OHMS RESISTANCE. THREE
DISTANCES SHALL BE USED 1 AT 100 FEET, 1 AT 70 FEET, AND 1 AT 35 FEET. THESE
DISTANCES ARE SUBJECT TOASITE BY SITE BASIS. T- MOBILE -WTS SHALL BE GIVEN 24
HOURS NOTICE. ALL COSTS ASSOCIATED WITH GROUND TESTING WILL BEAT THE
EXPENSE OF THE CONTRACTOR.
1 ELECTRICAL GROUNDING PLAN
E-1 22x34 SCALE: 1/2" = 1'
1 1x17 SCALE: 1/4" = 1'
GF$OUNDI NG NOTE,
GF?OUND HYBRID CABLE TOP & BOTTOM USING
UKJI VERSAL 15/8" GROUNDING STRAP. PART #252172
T • •Mobile•
= PROJECT INFORMATION:
WILKENSON
ROAD /RAILWAY
SE05198D
16220 RAILWAY ROAD SE
YELM, WA 98597
BUILDING PER
= REVISION HISTORY:
NO. DATE: DESCRIPTION: CHK.APPV.
BY: BY:
=PLANS PREPARED BY:
B. J. THOMAS, P.E.
7607 80TH AVE NE
MARYSVILLE, WA 98270
206- 851 -1106
=DRAWN BY: CHK. BY: =APPV. BY::
AAL ::B:J KC
NEW RADIO EQUIPMENT & NEW ANTENNAS.
= DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF
DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR
DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED
CLIENT IS STRICTLY PROHIBITED.
NG TITLE:
ELECTRICAL
GROUNDING PLAN
NUMBER:
Emi
3
1/15/2014
UPDATE CODE COMPLIANCE&
PROJECTTEAM
BJT
Al
A2
REV. PER REDLINES
BUT
KC
4/25/2013
ISSUED DESIGN REVIEW
BJT
KC
=PLANS PREPARED BY:
B. J. THOMAS, P.E.
7607 80TH AVE NE
MARYSVILLE, WA 98270
206- 851 -1106
=DRAWN BY: CHK. BY: =APPV. BY::
AAL ::B:J KC
NEW RADIO EQUIPMENT & NEW ANTENNAS.
= DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF
DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR
DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED
CLIENT IS STRICTLY PROHIBITED.
NG TITLE:
ELECTRICAL
GROUNDING PLAN
NUMBER:
Emi
HARGER GROUNDING BAR #GB14824 (OR EQUAL)
WITH HOLE PATTERN, STANDOFF INSULATORS
AND MOUNTING BRACKETS AS SHOWN
#2 GREEN INSULATED COPPER
WIRE TO AGE AT TOP OF POLE
COAX CABLE GROUNDING KITS WITH
LONG BARREL COMPRESSION LUGS, HARGER GROUNDING BAR
INSTALLED BY CONTRACTOR.
#G8114412G OR EQUAL
0 ANTENNA MOUNT GROUND
® COAX CABLE
® GROUNDING KITS
® ® ® ® ® ® Q
® G
® #2 SOLID BARE TINNED ®®
COPPER WIRE TO
GROUND ) PER MOPING - PROVIDE ® ®
(2) PER MOB
#2 GREEN INSULATED COPPER WIRE TO
® -
MOB AT BOTTOM OF POLE
® - = CADWELD
m
1 TYPICAL CADWELD CONNECTIONS
E-2 N.T.S. (D
TYPICAL MGB TYPICAL AGB
r-2 GROUND BAR DETAILS
E -2 N.T.S.
TYPE TA TYPE VN TYPE NO TYPE SS
TYPE W TYPE VS TYPE VB TYPE PT
TYPE GT TYPE GY TYPE OR
T • •Mobile•
= PROJECT INFORMATION:
WILKENSON
ROAD /RAILWAY
SE05198D
16220 RAILWAY ROAD SE
YELM, WA 98597
= ISSUED FOR:
BUILDING PERMIT
= REVISION HISTORY:
NO. DATE:
DESCRIPTION: CHK. APPY.
BY: BY:
111512014 uaogTE CODE COMPUgNCEa BUT Al
3 PROJECT TEAM
5115/2013 REV_ PER REDLINES PUT KC
0
TYPE GL
T • •Mobile•
= PROJECT INFORMATION:
WILKENSON
ROAD /RAILWAY
SE05198D
16220 RAILWAY ROAD SE
YELM, WA 98597
= ISSUED FOR:
BUILDING PERMIT
= REVISION HISTORY:
NO. DATE:
DESCRIPTION: CHK. APPY.
BY: BY:
111512014 uaogTE CODE COMPUgNCEa BUT Al
3 PROJECT TEAM
5115/2013 REV_ PER REDLINES PUT KC
0
=PLANS PREPARED BY:
B. J. THOMAS, P.E.
7607 80TH AVE NE
MARYSVILLE, WA 98270
206. 851 -1106
=DRAWN BY: CHK. BY: =APPY. BY:=
AAL BJ KC
RE
= EQUIPMENT:
NEW RADIO EQUIPMENT &NEW ANTENNAS.
= DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF
DOCUMENTS IS PROPRIETARY BY NATURE. ANY
USE OR
DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED
CLIENT IS STRICTLY PROHIBITED.
TITLE:
ELECTRICAL
GROUNDING
DETAILS
NUMBER:
E -2
25/2013
ISSUED DESIGN REVIEW
BJT
KC
=PLANS PREPARED BY:
B. J. THOMAS, P.E.
7607 80TH AVE NE
MARYSVILLE, WA 98270
206. 851 -1106
=DRAWN BY: CHK. BY: =APPY. BY:=
AAL BJ KC
RE
= EQUIPMENT:
NEW RADIO EQUIPMENT &NEW ANTENNAS.
= DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF
DOCUMENTS IS PROPRIETARY BY NATURE. ANY
USE OR
DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED
CLIENT IS STRICTLY PROHIBITED.
TITLE:
ELECTRICAL
GROUNDING
DETAILS
NUMBER:
E -2
JUL & DL FREQUENCIES FOR SEATTLE MARKET:
PCS',
UL', 1885 -1895 MHZ, 1900 -1905 MHZ
BE 1965 - 1975 Mhz, 1980 - 1985 Mhz
AWS',
UL: 1745 -1755 Mhz
DL: 2145 - 2155 Mhz
12
51"
'3
ANDREW ANTENNA
DATA
PART#
SITE
LOADING CHART
MECHANICAL
MECHANICAL
ELECTRICAL
RADIATION CENTER
HYBRID CABLE
COAX AMOUNT
SECTOR
34.616.
ANTENNA MODEL #
VENDOR
AZIMUTH (TN)
(4) 7 -16 DIN INCLUDED
7 -16 DIN FEMALE
AWS FULL BAND TWIN AISG TVA WITH VSWF ALARM
ELECTRICAL SPECIFICATIONS
FREQUENCY
FREQUENCY
DOWNTILT
ELEVATIONEW
LENGTH
& SIZE
1.2
VSWR MAX INPUT POWER
TMBXX- 6516 -R2M
ANDREW
13511165 1 250 WATTS
ALPHA
350
TBD
TED
147 -9" AGL
(4)7/8"
TMBXX- 6516 -R2M
ANDREW
TMBXX- 6516 -R2M
ANDREW
BETA
120`
TBD
TBD
147' -9" AGL
175
A) 7/8"
TMBXX- 6516 -REM
ANDREW
TMBXX- 6516 -R2M
ANDREW
GAMMA
240°
TBD
TBD
147' -9 "AGL
(4) 7/8"
TMBXX- 6516 -R2M
ANDREW
JUL & DL FREQUENCIES FOR SEATTLE MARKET:
PCS',
UL', 1885 -1895 MHZ, 1900 -1905 MHZ
BE 1965 - 1975 Mhz, 1980 - 1985 Mhz
AWS',
UL: 1745 -1755 Mhz
DL: 2145 - 2155 Mhz
12
51"
'3
ANDREW ANTENNA
DATA
PART#
MECHANICAL SPECIFICATIONS
WIDTH
DEPTH
PART NUMBER HEIGHT WIDTH
DEPTH
WEIGHT
TMBXX -6516 -R2M 59 in (with actuator) 11,9 in
'6.3 in
34.616.
CONNECTORS STANDARD MOUNTING HARDWARE
MOUNTING CONNECTOR
I PART NAME
(4) 7 -16 DIN INCLUDED
7 -16 DIN FEMALE
AWS FULL BAND TWIN AISG TVA WITH VSWF ALARM
ELECTRICAL SPECIFICATIONS
FREQUENCY
FREQUENCY
FREQUENCY POLARIZATION GAIN AZIMUTH �,W.
ELEVATIONEW
1710 -2155 MHz ±45` 17.5 °3 0.8
64.5,
1.2
VSWR MAX INPUT POWER
7 -30 Vdc
13511165 1 250 WATTS
NOTE:
1. ALL COAXIAL CABLE CONNECTIONS TO BE WEATHER PROOFED.
2. CONTRACTOR TO DIP CABLES AND JUMPERS WHERE NECESSARY,
3. TAGGING:
• ALL COAXIAL CABLES TO BE MARKED WITH COLOR CODED TAPE TO INDICATE THE ANTENNA SECTOR.
• COLORED ELECTRICAL TAPE SHALL MARK EACH END OF CABLE AND EACH END OFJUMPERS AS CLOSE TO
EACH END AS POSSIBLE. (NOT TO INTERFERE WITH WEATHERPROOFING.)
4. COAXIAL CABLE SPECIFICATIONS REQUIRE CABLE SUPPORT EVERY 3' -0" ON CENTER. CONTRACTOR SHALL
SUPPLY SUPPORTS AS REQUIRED TO MEET THIS REQUIREMENT,
5. VERTICAL CONNECTIONS SHALL BE TAPED FROM THE BOTTOM UP SO OVERLAP MOVES WATER AWAY FROM
CONNECTION. (SEE STEP 4.)
6. PROVIDE HEAT SHRINK IN PLACE OF TAPE FOR QUAD POLES AND TMA'S. HEAT SHRINK SHALL BE "CANUSA" WITH
ADHESIVE.
con
2ICAL
BUTYLTAPE
A MASTIC TAFFY TLPM
CROSSBAND COUPLER- PCS /AWS "DIPLEXER"
MECHANICAL SPECIFICATIONS:
PART#
LENGTH
WIDTH
DEPTH
WEIGHT
ECC1920 -VPUB
7.56" T 92mm)
7.32" (186mm)
2.8" (72mm)
3.6 kg (7.9 lb)
CONNECTORS
MOUNTING CONNECTOR
I PART NAME
TYPE "RF"
7 -16 DIN FEMALE
AWS FULL BAND TWIN AISG TVA WITH VSWF ALARM
ELECTRICAL SPECIFICATIONS:
FREQUENCY
FREQUENCY
GAIN
4125/2013
POWER HANDLING
AWS (1850 -1910 MHz)
1710 -1755 MHz /2110-2155 MHz
12 dB 2.6
7 -30 Vdc
ELECTRICAL TAPE'. 3 LAYERS WITH 2' TAPE AND 3
LAYERS IN 3/4" TAPE (ALL WITH MINIMUM 50% OVERLAP).
ALL TAPE ENDS SHALL
"A.... 1— 3M SC
STEP 1 STEP 2 STEP 3
t COAXIAL CABLE WEATHERPROOFING
RF -1 SCALE: NTS
ANTENNA AND COAX GENERAL NOTES:
1, ALL ANTENNA AND (COAXIAL ANTENNA CABLE TO BE FURNISHED BY T-MOBILE AND
INSTALLED BY CON "TRACTOR.
2. COAX COLOR CODIING ANTENNAS TO BE NUMBERED IN A CLOCKWISE MANNER FROM
TRUE NORTH AND CIOLOR CODED AS FOLLOWS:
3. THE ABOVE COAX DOLOR CODING APPLIES TO SECTORIZED SITES. FOR OMNI SITES,
USE THE ATO, BTO. ffi GTO COLOR CODES ONLY
4. COAX SHALL BE TArGED WITH COLOR CODING AT (2) PLACES USING 1" WIDE WEATHER
PROOF COLORED VIINYL TAPE AT THE FOLLOWING LOCATIONS:
#1 -AT ANTENNA CONNECTION
#2 -AT ENTRY TO EQUIPMENT CABINET
5. RUN COAXIAL CABLE WITH MINIMUM 12" SLACK & 12" FROM EDGE OF EQUIPMENT
CABINETS, ACROSS WAVE GUIDE BRIDGE (IF APPLICABLE), UP TO TOWER LEG (IF
APPLICABLE). & DISTRIBUTE TO EACH ANTENNA DEVICE. FURNISH AND INSTALL
MINIMUM OF (3) GROUND KITS PER COAXIAL CABLE ACCORDING TO ELECTRICAL
DRAWINGS. VERIFY NUMBER OF ANTENNAS, CABLE, & CABLE DIAMETER WITH PROJECT
MANAGER.
o 7 0
o O
5.5' 7.7" ❑O
O
6.3,
11.85'
AWS WITH AISG TMA DATA
MECHANICAL SPECIFICATIONS:
PART#
LENGTH
WIDTH
DEPTH
WEIGHT
ETW20OVS12UB
6.3" (160mm)
7.7" (196mm)
3" (78mm)
5 kg (,11 lb)
CONNECTORS
MOUNTING CONNECTOR
I PART NAME
TYPE "LONG NECK"
7 -16 DIN FEMALE
AWS FULL BAND TWIN AISG TVA WITH VSWF ALARM
ELECTRICAL SPECIFICATIONS:
FREQUENCY
REV. PER
GAIN
4125/2013
POWER HANDLING
AWS (1850 -1910 MHz)
12 dB 2.6
7 -30 VdC
T • •Mobile•
= PROJECT INFORMATION:
WILKENSON
ROAD /RAILWAY
SE05198D
16220 RAILWAY ROAD SE
YELM, WA 98597
BUILDING PERMIT
= REVISION HISTORY:
NO. DATE: DESC
=PLANS PREPARED B'.:
B. J. THOMAS, P.E.
7607 80TH AVE NE
MARYSVILLE, WA 98270
206.851.1106
=DRAWN BY: CHK. BY: =APPV. BY::
AAL BJ KC
NEW RADIO EQUIPMENT & NEW ANTENNAS.
= DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OFANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF
DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR
DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED
CLIENT IS STRICTLY PROHIBITED.
NG TITLE:
RF DETAILS
NUMBER:
RFm I
3
1/15/2014
UPDATE DO
PROJECTTE
A5/15/2013
REV. PER
4125/2013
ISSUED DE
=PLANS PREPARED B'.:
B. J. THOMAS, P.E.
7607 80TH AVE NE
MARYSVILLE, WA 98270
206.851.1106
=DRAWN BY: CHK. BY: =APPV. BY::
AAL BJ KC
NEW RADIO EQUIPMENT & NEW ANTENNAS.
= DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OFANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF
DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR
DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED
CLIENT IS STRICTLY PROHIBITED.
NG TITLE:
RF DETAILS
NUMBER:
RFm I
T • •Mobile•
= PROJECT INFORMATION:
WILKENSON
ROAD /RAILWAY
SE05198D
16220 RAILWAY ROAD SE
YELM, WA 98597
= ISSUED FOR:
BUILDING PERMIT
= REVISION HISTORY:
NO. DATE: DESCRIPTION: CNK. APPV. I
BY: BY:
=PLANS PREPARED BY:
B. J. THOMAS, P.E.
7607 80TH AVE NE
MARYSVILLE, WA 98270
206. 851.1106
=DRAWN BY: CHK. BY: =APPV. BY:-
AAL BJ KC
EQUIPMENT:
NEW RADIO EQUIPMENT & NEW ANTENNAS.
rDRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF
DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR
DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED
CLIENT IS STRICTLY PROHIBITED.
TITLE:
RF DETAILS
NG N
RFm2
3
1/15/2014
UPDATE CODE COMPLIANCE&
PROJECT TEAM
BJT
Al
A511
512 01 3
REV. PER REDLINES
BJT
NO
Q4125/2013
ISSUED DESIGN REVIEW
BJT
KC
=PLANS PREPARED BY:
B. J. THOMAS, P.E.
7607 80TH AVE NE
MARYSVILLE, WA 98270
206. 851.1106
=DRAWN BY: CHK. BY: =APPV. BY:-
AAL BJ KC
EQUIPMENT:
NEW RADIO EQUIPMENT & NEW ANTENNAS.
rDRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF
DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR
DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED
CLIENT IS STRICTLY PROHIBITED.
TITLE:
RF DETAILS
NG N
RFm2