20130114 Layer Res Plan Country Vista 06132013BUILDING CODE: 2009 INTERNA710NAL BLDG. CODE (IBC), AND BY REFERENCE WHERE APPLICABLE
THE 2009 INTERNATIONAL RESIDENTIAL CODE (IRC) AS AMENDED BY LOCAL JURI6DIC710N.
ROOF LIVE LOAD = 25 P5F (SNOW)
ROOF DEAD LOAD • 15 PSF
FLOOR LIVE LOAD = 40 PSF (REDUCIBLE)
FLOOR DEAD LOAD = 15 PEW
WIND LOAD = 65 MPH WIND SPEED, EXPOSURE 'B'
SOIL SITE CLASS 'D'
CONSTRUCTION TYPE: V
OCCUPANCY GROUP: R -3
DESIGN CRITERIA: TABLE R30110 U
GROUND
SNOW
WIND
SPEED
SEISMIC
DESIGN
SUBJECT 70 DAMAGE FROIM
WINTER
DESIGN
ICE SHIELD
UNDER-
LAYMEN?
FLOOD
HAZARDS
AIR
FREEZING
MEAN
ANNUAL
APPLICATION
FROST LI
2,500 psi
FLOOR SLAB.
LOAD
BASEMENT WALLS, FOUNDATION WALLS, EXTERIOR WALL5 d OTHER
CATEGORY
WEATHER(
DEPTH
?EPoMII
DECAY
TEMP.
REQUIRED
HAVE A MIN. NET
INDEX
TEMP
u ✓o adhaeive
15E PROTECTED BY THE INSTALLATION OF APPROVED METAL COLLARS OR METAL
19/64' NEADpID9B'
SCREEN SECURELY FASTENED TO THE ADJOINING STRUCTURE WITH NO OPENING
S
MINIMUM
SLIGHT-
SLIGHT
11
NO
PER
AL
50
50
30
(mph)
DI/D2
MOD
IB
MOD
EITHER DIRECTION
16
T
JURISDIG110N
5d COOLER NAIL 0.086'
R -10
ADDITIONAL REQUIRED SUBMITTAL ITEMS
ITEMS TO BE ME MITTED BY THE OWNER OR CONTRACTOR AT TM OF PERMIT SUBMITTAL:
- MFG JST. DESIGN AND LAYOUT IF APPLICABLE (FROM MMUFACIURBR)
- MFG. TRlrvr DESIGN AND LAYOUTS (FROM MAIIFACTUiER)
SITE WORK
GENERAL
UNLESS A SOILS INVESTIGATION BY A QUALIFIED SOILS ENGINEER IS PROVIDED,
FOUNDATION DESIGN IS BASED ON AN ASSUMED AVERAGE SOIL BEARING OF 1500 PSF.
EXTERIOR FOOTINGS SHALL BEAR 18' (MINIMUM) BELOW FINISHED GRADE. ALL FOOTINGS
TO BEAR ON FIRM UNDISTURBED EARTH BELOW ORGANIC SURFACE SOILS. BACKFILL TO
BE THOROUGHLY COMPACTED.
• rJh�
CONCRETE 'BATCH TICKET' SHALL BE AVAILABLE ON SITE FOR REVIEW BT BUILDING OFFICIAL
REINFORCEING STEEL TO COMPLY WITH 45TM A615 GRADE 40. UN.O.
WALL CONSTRUCTIONA RAMMG
GENERAL
ALL NAILING TO COMPLY WITH REQUIREMENTS OF IRC TABLE 860230)
GYPSUM WALL BOARD AT INTERIOR WALLS TO BE FASTENED AGCOWNG TO TABLE R'10235
MINIMUM THICKNESS AND APPLICATION OF GYPSUM BOARD
MINIMUM COMPRESSIVE STRENGTH Wc) AT 28 DAYS
TYPE OR LOCATIONS OF CONCRETE CONSTRUCTION
HF 02 - Fb•915 psi, Fv-150 psi, Fc =1300 psl, E- 1300000pal
ORIENTATION
MODERATE WEATHERING POTENTIAL
BASEMENT WALL$, FOUNDATION d OTHER CONCRETE NOT EXPOSED
2,500 pal
TO THE WEATHER
APPLICATION
BASEMENT SLABS 1 INTERIOR SLAB ON GRADE, EXCEPT GARAGE
2,500 psi
FLOOR SLAB.
TO WOO ING
BASEMENT WALLS, FOUNDATION WALLS, EXTERIOR WALL5 d OTHER
300 pal (41/2% air arilralned N- 11/2%)
VERTICAL CONCRETE WORK EXPOSED 70 THE WEATHER
MEMBERS
(INCHES O.O.)
PORCHES, CARPORT SLABS d STEPS EXPOSED
3p00 psi (41/2% air antralnad N- 1112%)
70 THE WEATHER d GARAGE FLOOR SLAB.
DF -L 01 - Fb =1200 pal, Fv-110 pal, Fc.1000 pal, E =1600000psi
CONCRETE 'BATCH TICKET' SHALL BE AVAILABLE ON SITE FOR REVIEW BT BUILDING OFFICIAL
REINFORCEING STEEL TO COMPLY WITH 45TM A615 GRADE 40. UN.O.
WALL CONSTRUCTIONA RAMMG
GENERAL
ALL NAILING TO COMPLY WITH REQUIREMENTS OF IRC TABLE 860230)
GYPSUM WALL BOARD AT INTERIOR WALLS TO BE FASTENED AGCOWNG TO TABLE R'10235
MINIMUM THICKNESS AND APPLICATION OF GYPSUM BOARD
TABLE RT0235
THICIQJESS OF
HF 02 - Fb•915 psi, Fv-150 psi, Fc =1300 psl, E- 1300000pal
ORIENTATION
MAXIMUM SPACING
MAXIMUM SPACING
OF NAIL FOR
LIC
APPA710N
GYPSUM BOARD
APPLICATION
OF GYPSUM
OF FRAMING
OF FASTENERS (INCHES)
TO WOO ING
(INCHES)
THI5 SECTION SHALL BE OBTAINED BY THE NORMAL
BOARD TO
FRAMING
MEMBERS
(INCHES O.O.)
NAILS
SOREUIS
13 GAGE I -3/S' LONG
DF -L 01 - Fb =1200 pal, Fv-110 pal, Fc.1000 pal, E =1600000psi
HAVE A MIN. NET
(FRAMED CONSTRUCTION TO CRAWL SPACE AT OR BELOW THE FIRST FLOOR SHALL
CLEAR OPENING OF 5.1 5Q. FT.
u ✓o adhaeive
15E PROTECTED BY THE INSTALLATION OF APPROVED METAL COLLARS OR METAL
19/64' NEADpID9B'
SCREEN SECURELY FASTENED TO THE ADJOINING STRUCTURE WITH NO OPENING
S
MINIMUM
P NING HEIGHT:
THE MIN
NET
CLEAR
DIA 1 -I/4' LONG
ANNULAR- RINGED
OP�NINCa51-
, f- ETGFIt3`F7AL
B 2 4
NC Tlt_-S_
032
�A
DRAF
TSTOPF!MG
CEILING
EITHER DIRECTION
16
T
12
5d COOLER NAIL 0.086'
R -10
DIA 1-5/8' LOW 5/64'
HEAD OR GTPA BOARD
N
GEILG
P'ERP'ENDICULAR
24
1
12
WALL
EITHER DIRECTION
24
8
12
lrz•
1-
N41L�dID86' DIA I -5/8' LUNG
t'2
OPERABLE WINDOW IS LOCATED MORE THAN l2'
1'�
WALL
EITHER DIRECTION
16
8
16
I. CEILING 15 SUSPENDED UNDER THE FLOOR FRAMING.
GEILmYa
EITHER DIRECTION
16
T
12
13 GAGE I -5/e' LONG
19/64' HEADfdD9B'
DIA LONG
GEILNG
PERPENDICULAR
24
1
12
WALL
EITHER DIRECTION
1 24
8
12
9/e'
ANNULAR-RIMED LAR- LAR- RINGED
6.1 COOLER NAIL 00W
DIA 1 -1/8' LOW 1/4'
HEAD OR GYPSUM BOARD
WALL
I EITHER DIRECTION
1 16
8
16
NAILOID W DIA 1 -1a' LONG
15/64' HEAD
FASTENERS
ALL NAILS SPECIFIED ON THIS PLAN SHALL BE COMM OR GALVANIZED BOX (UNLESS NOTED OTHERUSE) OF THE DIAIMETER AND
LENGTH LISTED BELOW OR AS PER APPENDIX L OF THE NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRJGTION (NDS)
8d COMMON (0.131' DIA, 2 -1/2' LENGTH), 8d BOX (0.113' DIA, 2 -IRE' LONG), Imd COMMON (0.148' DIA., 3' LONG)
10d BOX (0.128' DIA, 3' LENGTH), 16d COMMON (0.162' DIA, 3 -1/2' LONG), 16d SINKER (0.148 DIA, 3 -1/4' LONG)
5d COOLER (0 .086' DIA, I -5/8' LONG ), bd COOLER (0.092' DIA, 1 -1/8' LONG)
LUMBER GRADES
FRAMING LUMBER SHALL COMPLY WITH THE LATEST EDITION OF THE GRADING
RULES OF THE WESTERN PRODUCTS ASSOCIATION OR THE WEST COA5T LUMBER
INSPECTION BUREAU. ALL SAWN LUMBER SHALL BE STAMPED WITH THE GRADE
MARK OF AN APPROVED LUMBER GRADING AGENCY AND SHALL HAVE THE
FOLLOWING UNADJUSTED DESIGN MINIMUM PROPERTIES:
JOISTS:
WOOD TYPE:
2X4
HF 02 - Fb•915 psi, Fv-150 psi, Fc =1300 psl, E- 1300000pal
2X6 OR LARGER
HF 2 - Fb.915 pal, FV =150 psi, Fc =1300 pal, E•1300000ps1
4X
DF -L 02 - Fb =900 pai, Fv =180 psi, Fc =1350 psi, E•1600000psl
6X OR LARGER
DF-L'2 - Fb.815 psi, Fv =110 pal, F0=600 pal, E•1300000ps1
STUDS
2X4
HF 2 - Fb•915 pal, Fv.150 psi, Fc =1300 pal, E- 1300000p51
2X6 OR LARGER
HF 2 - Fb•915 pal, Fv-150 pal, Fo -1300 pal, E=130000 -PST
F OS79
THI5 SECTION SHALL BE OBTAINED BY THE NORMAL
4X4
HF 2 - Fb•9l5 pal, Fv =150 pal, Fc =1300 pal, E•1300000pa1
4X6 OR LARGER
HF 2 - Fb =915 pal, Fv-150 pal, FC -1300 pal, E =1300000pei
6X6 OR LARGER
DF -L 01 - Fb =1200 pal, Fv-110 pal, Fc.1000 pal, E =1600000psi
(I UPn_I AMINATED BEAM (GLB)
SHALL BE 24F -V4 FOR SINGLE SPANS d 24F -V8 FOR CONTINUOUS OR CANTILEVER SPANS
WITH THE FOLLOWING MINIMUM PROPERTIES:
Fb - 2,400 PSI, Fv . 165 PSI, Fc . 650 PSI (PERPENDICULAR), E • 1,800,000 PSI,
FNIr INFFRFI) WOOD BEAMS AND [-JOIST
CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AND SPECIFICATIONS FOR APPROVAL BY
BUILDING OFFICIAL. DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST
ICI EVALUATION REPORT.
BEAMS DESIGNATED AS 'f-SL' SHALL HAVE THE MINIMUM PROPERTIES:
Fb • 2,900 PSI, Fv . 290 PSI, Fc . '150 PSI (PERPENDICULAR), E - 2,000,000 P51.
BEAMS DESIGNATED AS 'LVL' SHALL HAVE THE MINIMUM PROPERTIES:
Fb . 2 )&00 PSI, Fv . 285 PSI, Fc = ISO PSI (PERPENDICULAR), E = 1,900,000 PSI.
BEAMS DESIGNATED AS 'LSL' SHALL HAVE THE MINIMUM PROPERTIES:
Fb . 1,100 PSI, Fv = 400 PSI, Fc = 680 PSI (PERPENDICULAR), E = 1,300,000 PSI.
CALCULATION5 SHALL INCLUDE DEFLECTION AND CAMBER REQUIREMENTS.
DEFLECTION SHALL BE LIMTED AS FOLLOWS:
FLOOR LIVE LOAD MAXIMUM = L/480, FLOOR TOTAL LOAD MAXIMUM = L/240.
WALL CONSTRUGTIONA RAMMG (CONTINUED)
PREFABRICATED WOOD TRUSSES:
PREFABRICATED WOOD TRUSSES SHALL BE DESIGNED TO SUPPORT SELF WEIGHT PLUS LIVE
LOAD AND SUPERIMPOSED DEAD LOADS AS STATED IN THE GENERAL NOTES. TRUSSES SHALL BE DESIGNED
d STAMPED BY A LICENSED PROFESSIONAL ENGINEER AND FABRICATED ONLY FROM THOSE DESIGNS.
NONBEARING WALLS SHALL BE HELD AWAY FROM THE TRUSS BOTTOM CHORD WITH AN APPROVED
FASTENER (SIKH AS SIMPSON STC) 70 ENSURE THAT THE TRUSS BOTTOM CHORD WILL NOT BEAR ON THE WALL.
ALL PERMANENT TRUSS MEMBER BRACING SHALL BE INSTALLED PER THE TRUSS DESIGN DRAWINGS.
ROOFNIALL/FLOOR SHEATHING
TYPICAL WALL d ROOF SHEATHING SHALL BE 1116' RATED SHEATHING MINIMUM UNLESS OTHERWISE SPECIFIED.
MINIMUM NAILING SHALL BE 8d COMMON a 6' O.G. ® PANEL EDGES AND 12' O.C. IN FIELD UN.O. ON SHEARWALL
SCHEDULE. SPAN INDEX SHALL BE 24/0 FOR WALLS AND 24/16 FOR ROOF. FLOOR SHEATHING SHALL BE
3/4' TKG RATED (40/20) SHEATHING, UNLESS OTHERWISE SPECIFIED. MINIMUM NAILING SHALL BE 6d COMMOM AT W O.C.
a PANEL EDGES AND 12' O.C. IN FIELD. SPAN INDEX SHALL BE 40/20 UNLESS NOTED OTI-EWISE. STAGGER END LAPS AT ROOF
AND FLOOR SHEATHING.
WALL FLASHING
APPROVED CORROSION- RESISTANT FLASHING SHALL BE PROVIDED IN THE EXTERIOR
WALL ENVELOPE IN SUCH A MANNER AS TO PREVENT ENTRY OF WATER INTO THE WALL
CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING COMPONENTS.
THE FLASHING SHALL EXTEND 70 THE SURFACE OF THE EXTERIOR WALL FINISH AND SHALL BE I1,15TALLED
TO PREVENT WATER FROM REENTERING THE EXTERIOR WALL ENVELOPE. APPROVED CORROSION-RESISTANT
FLA51LING5 SHALL BE INSTALLED AT ALL OF THE FOLLOWING LOCATIONS:
I. AT TOP OF ALL EXTERIOR WINDOW AND DOOR OPENINGS IN SUCH A MANNER AS 70 BE LEAKPROOF,
EXCEPT THAT SELF - FLASHING WINDOWS HAVING A CONTINUOUS LAP OF NOT LESS THAN I -1 18'
(28 mm) OVER THE SHEATHING MATERIAL AROUND THE PERIMETER OF THE OPENING, INCLUDING
CORNERS, DO NOT REQUIRE ADDITIONAL FLASHINGt JAMB FLASHING MAY AL50 BE
OMITTED WHEN SPECIFICALLY APPROVED BY THE BUILDING OFFICIAL.
2. AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY CONSTRUCTION WITH FRAME
OR STUCCO WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER STUCCO OPENINGS.
3. UNDER AND AT THE ENDS OF MASONRY, WOOD, OR METAL COPINGS AND SILLS.
4. CONTINUOUSLY ABOVE ALLPROJECTING WOOD TRIM.
5. WHERE EXTERIOR PORCHES, DECKS, OR STAIRS ATTACH 70 A WALL OR FLOOR ASSEMBLY
OF WOOD CONSTRUCTION.
6. AT WALL AND ROOF INTERSECTIONS.
1. AT BUILT -N GUTTERS.
FOUNDATION (CONTINUED)
I. BITUMNOU5 COATING
2.3 POUNDS PER SQ. YD. OF ACRYLIC MODIFIED CEMENT
3. g' COAT OF SURFACE BONDING CEMENT COMPLYING WITH ASTN C 881
4. ANY MATERIAL APPROVED FOR WATERPROOFING IN SEC. R4061
5. OTHER APPROVED METHODS OR MATERIALS.
EXCEPTION: PARGING OF UNIT MASONRY WALLS 15 NOT REQUIRED WERE A MATERIAL IS
APPROVED FOR DIRECT APPLICATION TO THE MASONRY.
WATERPROOFING
N AREAS WHERE HIGH WATER TABLE OR OTHER SEVERE SOIL-WATER CONDITIONS ARE
KNOWN TO EXIST, EXTERIOR FOUNDATION WALLS THAT RETAIN EARTH OR ENCLOSE INTERIOR
SPACES AND FLOORS BELOW GRADE SHALL BE WATERPROOFED FROM THE TOP OF FOOTINCa
TO FINISHED GRADE. WALL5 SHALL BE WATERPROOFED IN ACCORDANCE WITH ONE OF THE
FOLLOWING.
I. 2 -PLY HOT MOPPED FELT
2. 55 POUND ROOF ROLLING
3. 6 -MIL POLYVINYL CHLORIDE
4.6 -MIL POLYETHYLENE
5. 40 -MIL POLTMER - MODIFIED ASPHALT
6, 60 -MIL FLEXIBLE POLYMER CEMENT
T I /8' CEMENT- BASED, FIBER - REINFORCED, WATERPROOF COATING
6. 60 -MIL 5OLVANT -FREE, LIQUID- APPLIED SYNTHETIC RUBBER
EXCEPT ION: ORGANIC- SOLVANT -BASED PRODUCTS SUCH AS HYDROCARBONS,
CHLORINATED HYDROCARBONS,
KETONS AND ESTERS SHALL NOT BE USED FOR ICF WALLS WITH EXPANDED
POLYSTYRENE FOAM MATERIAL. USE
OF PLASTIC ROOFING CEMENTS, ACRYLIC COATINGS, LATEX COATINGS, MORTARS AND
PARSING5 TO
SEAL ICF WALLS 15 PERMITTED. COLD - SETTING ASPHALT OR HOT ASPHALT SHALL
CONFORM TO TYPE G OF ASTM
D 449. HOT ASPHALT SHALL BE APPLIED AT A TEMPERATURE OF LESS THAN 200 DEG?. F.
ALL JOINTS IN MEMBRANE WATERPROOFING SHALL BE LAPPED AND SEALED WITH AN
ADHESIVE COMPATIBLE WITH 714E MEMBRANE.
EXTERIOR DOORS WINDOWS AND SKYLIGHTS
WINDOWS SHALL BE INSTALLED AND FINISHED N ACCORDANCE WITH THE MANUFACTURER'S
WRITTEN INSTALLATION INSTRUCTIONS WRITTEN INSTALLATION INSTRUCTIONS SHALL ISE
PROVIDED BY THE MANUFACTURER FOR EACH WINDOW.,
FRATPROOFING NOTE$:
ALL SKYLIGHTS AND SKY WALLS TO BE LAMINATED GLASS UNL556 NOTED OTHERWISE.
ALL GLAZING TO BE IN COMPLIANCE WITH THE LATEST
SECTION R310-EMERGENCY ESCAPE d RESCUE OPNGS
ALL REQUIIRERMENTS OF 2009 UNIFORN PLUMMBING CODE WITH WASH STATE AMENDMENTS
SLEEPING ROOMS SHALL HAVE AT LEAST ONE
SHALL
((UPC) SECT. 313.12 RAT PROOFING STRAINER PLATES ON DRAIN INLETS SHALL BE DESIGNED AND INSTALLED
AREA
SO THAT NO OPENING IS GREATER THAN 1/2' IN THE LEAST DIMENSION. 313.122
SUCH OPENINECs SHALL OPEN DIRECTLY INTO AG
(METER BOXES SHALL BE CONSTRUCTED IN SUCH A MANNER THAT RATS CANNOT
PUBLIC STREET, PUBLIC ALLEY, YARD OR COURT.
(ENTER A BUILDING BY FOLLOWING THE SERVICE PIPES FROM THE BOX INTO THE
THE NET CLEAR OPENING DIMENSIONS REQUIRED BY
BUILDING. 313.123 IN OR ON BUILDINGS WHERE OPENINGS HAVE BEEN MADE IN WALLS,
THI5 SECTION SHALL BE OBTAINED BY THE NORMAL
IFLOORS, OR CEILINGS FOR THE PASSAGE OF PIPES, SUCH OPENINGS SHALL BE
OPERATION OF THE EMERGENCY ESCAPE AND
RESCUE OPENING FROM THE INSIDE.
(CLOSED AND PROTECTED BY THE INSTALLATION OF APPROVED METAL COLLARS
MINIMUM OPENING AREA: ALL EMERGENCY ESCAPE
SECURELY FASTENED TO THE ADJOINING STRUCTURE. 313.12.4 TUB WASTE OPENINGS IN
AND RESCUE OPENINGS SHALL
HAVE A MIN. NET
(FRAMED CONSTRUCTION TO CRAWL SPACE AT OR BELOW THE FIRST FLOOR SHALL
CLEAR OPENING OF 5.1 5Q. FT.
13%
15E PROTECTED BY THE INSTALLATION OF APPROVED METAL COLLARS OR METAL
EXCEPTION: GRADE FLOOR OPENINGS SHALL HAVE
A MIN. 5.0 SQ. FT.
SCREEN SECURELY FASTENED TO THE ADJOINING STRUCTURE WITH NO OPENING
S
MINIMUM
P NING HEIGHT:
THE MIN
NET
CLEAR
(3SEATER THAN 1/2' IN THE LEAST DIMENSION.
OP�NINCa51-
, f- ETGFIt3`F7AL
B 2 4
NC Tlt_-S_
032
�A
DRAF
TSTOPF!MG
-
4 FIRE
OLOCKMG
R -21
MINIMUM OPENING WIDTH: THE MIN
NET CLEAR
R -10
III
UNLIMITED
030
050
010
9
a 8,38
OPENING WIDTH SHALL BE 20 INCHES.
8`21
DRAFTSTOPPING
MAXIMUM SILL HEIGHT: MAX. 44'
WHEN THERE IS USABLE SPACE BOTH ABOVE d BELOW THE CONGEALED SPACE OF A FLOOR/CEILINCs
IN DWELLING UNITS, WHERE THE OPENING OF AN
ASSEMBLEY, DR',AFi5TOF5 WALL BE INSTALLED SO THAT THE AREA OF THE CONCEALED SPACE DOES NOT EXCEED
OPERABLE WINDOW IS LOCATED MORE THAN l2'
I/DPJO SQUARE FEET. DRAFTS70PPING SHALL DIVIDE THE CONCEALED SPACE INTO APPROXIMATELY
ABOVE THE FINISHED GRADE OR SURFACE BELOW,
EQUAL AREAS. WHERE THE ASSEMBLY IS ENCLOSED BY A FLOOR MEMBRANE ABOVE 4 A CEILMG MIEMBRAENE BELOW, DRARSTOPPNG
THE LOWEST PART OF THE CLEAR OPENING OF THE
SHALL BE PROVIDED IN FLOOR/CEILING ASSEMBLIES UNDER THE FOLLOWING CIRCUMSTANCES:
WINDOW SHALL BE A MINIMUM OF 24' ABOVE THE
I. CEILING 15 SUSPENDED UNDER THE FLOOR FRAMING.
FINISHED FLOOR OF THE ROOM IN WHICH THE WINDOW
2. FLOOR FRAMING IS CONSTRUCTED OF TRUSS -TYPE OPEN -WEB OR PERFORATED MEMBERS.
15 LOCATED.
DRAFi5TOPPING SHALL CONSIST OF MATERIALS LISTED IN IRC SECTION 8302.12
SAFETY GLAZING SHALL BE INSTALLED N THE FOLLOWING LOCATIONS OR AS OTHERWISE REWIRED PER IRC SECTION 83084
FIREBLOCKING SHALL BE PROVIDED TO CUT OFF ALL CONCEALED DRAFT OPENINGS (BOTH VERTICAL
AND HORIZONTAL) AND 70 FORM AN EFFECTIVE 5ARR2IER BETWEEN STORIES, AND BETWEEN A TOP STORY AND THE
ROOF SPACE. FIREBLOCKING SHALL BE PROVIDED IN WOOD -FRAME CONSTRUCTION IN THE FOLLOWING LOCA710NS:
1. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES AND
PARALLEL ROWS OF STUDS OR STAGGERED STUDS AS FOLLOWS:
I.I. VERTICALLY AT THE CEILING AND FLOOR LEVELS.
12. HORIZONTALLY AT INTERVALS NOT EXCEEDING 10ft
2. AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH
AS OCCUR AT SOFFITS, DROP CEILINGS, AND COVE CEILINGS.
3. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RJN.
ENCLOSED SPACES UNDER STAIRS SHALL COMPLY WITH IRG SECTION 83025
4. AT OPENINGS AROUND VENTS, PIPES, AND DUCTS AT CEILING AND FLOOR LEVEL, WITH AN
APPROVED MATERIAL TO RESIST THE FREE PASSAGE OF FLAME AND PRODUCTS OF COMBUSTION.
5. FOR THE FIREBLOCKING OF CHIMNEYS AND FIREPLACES, SEE IRC SECTION R1003A
6. FIREBLOCKING OF CORNICES OF A TWO- FAMILY DWELLING IS REQUIRED AT THE LINE OF
DWELLING UNIT SEFERATION.
FIREBLOGKING SHALL CONSIST OF MATERIALS LISTED IN IRG SECTION 8302.11.1. LOOSE -FILL INSULATION
MATERIAL SHALL NOT BE USED AS A FIREBLOCK UNLESS SPECIFICALLY TESTED IN THE FOR'(
AND MANNER INTENDED. THE INTEGRITY OF ALL FIREBLOCK5 SHALL BE MAINTAINED.
INSULATION AND MOISTURE PROTECTION
MAINTAIN V CLEARANCE ABOVE INSULATION FOR FREE AIR FLOW.
INSULATION BAFFLES TO EXTEND W ABOVE BATT INSULATION
INSULATION BAFFLES TO EXTEND 12' ABOVE L005E FILL INSULATION
INSULATE BEHIND TUBS /SHOWERS, PARTITIONS AND CORNERS
FACE- STAPLE FACED BATTS
FRICTION -FIT UNFACED BATTS
USE 4 MIL POLY VAPOR RETARDER AT EXTERIOR WALLS
R -10 INSULATION UNDER ELECTRIC WATER HEATERS.
INSULATION MATERIALS
INSULATION MATERIAL, INCLUDING FACINGS, SUCH AS VAPOR RETARDERS OR VAPOR PERMEABLE
MEMBRANES INSTALLED WITHIN FLOOR - CEILING ASSEMBLIES, ROOF- CEILING ASSEMBLIES, WALL
ASSEMBLIES, CRAWL SPACES, AND ATTICS SHALL HAVE A FLAME- SPREAD INDEX NOT TO
EXCEED 25 WITH AN ACCOMPANYING SMOKE- DEVELOPED INDEX NOT TO EXCEED 450 WHEN
TESTED IN ACCORDANCE WITH ASTM E 84
EXCEPTIONS:
L WHEN SUCH MATERIAL ARE INSTALLED IN CONCEALED SPACES, THE FLAME - SPREAD AND SMIOKE- DEVELOFEtMENT
LIMITATIONS DO NOT APPLY TO THE FACINGS, PROVIDED THAT THE FACING IS INSTALLED
IN SUBSTANTIAL CONTACT WITH THE UNEXPOSED SURFACE OF THE CEILING, FLOOR OR WALL FINISH.
2. CELLULOSE LOOSE -FILL INSULATION, WHICH IS NOT SPRAY APPLIED, COMPLYING
WITH THE REQUIREMENTS OF IRC 83163, SHALL ONLY BE REQUIRED 70 MEET THE SMOKE- DEVELOPED
INDEX OF NOT MORE THAN 450.
INFILTRATION CONTROL
EXTERIOR JOINT$ AROUND WINDOWS AND DOOR FRAMES, PENETRATIONS IN FLOORS, ROOFS AND WALLS
AND ALL SIMILAR OPENINGS SHALL BE SEALED, CAULKED, GASKETED OR WEAT14EIRSTRIF MD TO LIMIT AIR LEAKAGE.
VAPOR BARRIERS / GROUND COVERS
AN APPROVED VAPOR BARRIER SHALL BE PROPERLY INSTALLED IN ROOF DECKS, IN
ENCLOSED CEILING SPACES AND AT EXTERIOR WALLS.
A GROUND COVER OF 6 MIL (0006') BLACK POLYETHYLENE OR EQUIVALENT SHALL BE
LAID OVER THE GROUND IN ALL CRAWL SPACES. THE GROUND COVER SHALL BE
OVERLAPPED 12' AT EACH JOINT AND SHALL EXTEND TO THE FOUNDATION WALL.
FOUNDATION
BOLT HEADS AND NUTS BEARING AGAINST WOOD TO BE PROVIDED WITH 1/4'x3'x3' PLATE WASHERS.
WOOD BEARING ON OR INSTALLED WITHIN V OF MASONRY OR CONCRETE TO BE PRESSURE
TREATED WITH AN APPROVED PRESERVATIVE.
FOUNDATION SILL 5OLT5 TO BE 5/8' DIAMETER AT V -0' O.C. UN.O. WITH MIN. l' EMBEDMENT
METAL FRAMING CONNEC70R5 TO BE MANUFACTURED BY SIMPSON STRONG -TIE OR USP STRJCTURAL CONNECTORS
ALL WOOD IN CONTACT WITH CONCRETE TO BE PRESSURE TREATED. FIELD CUT ENDS, NOTCHES, AND DRILLED HOLES OF
(ENE) CURE T TREATED LUMBER LMA ININ ZLEBBEROTREATED IN THE FIELD IN ACCORDANCE WITH AWPA M4.
PER IRC 3113, FASTENERS FOR PRESSURE PRESERVATIVE AND FIRE RETARDANT TREATED WOOD SHALL
BE OF NOT - DIPPED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE, OR COPPER
6' MIN. CLEARANCE BETWEEN WOOD AND GRADE.
12' MIN. CLEARANCE BETWEEN FLOOR BEAMS AND GRADE.
18' MIN. CLEARANCE BETWEEN FLOOR JOIST AND GRADE.
DAMPROOFING
EXCEPT WHERE REQUIRED BY SEC. R4062 TO BE WATERPROOFED, FOUNDATION WALLS THAT
RETAIN EARTH OR ENCLOSE INTERIOR SPACES AND FLOOR' 5 BELOW GRADE SHALL BE
DA-IPROOFED FROM THE TOP OF THE FOOTING TO THE FINISHED GRADE. MASONRY WALL5
C/I
SIDE.(- ZINGED DOORS
2. SLIDING GLASS DOORS AND PANELS IN SLIDING 4 BI -FOLD CLOSET DOOR ASSEMBLIES
3. STORM DOORS
4. SHOWER AND BATH TUB, HOT TUB, WHIRLPOOL, SAUNA, STEAM ENCLOSURES
5. GLAZING W/ THE EXPOSED EDGE WITHIN A 24' ARC OF EITTHER VERTICAL EDGE
OF A DOOR IN THE CLOSED POSITION 4 BOTTOM EDGE IS LESS THAN 60' ABOVE
THE WALKING SURFACE
6. GLAZING GREATER THAN 9 S.F. AND LESS THAN IS' AIBOVE FINISHED FLOOR
1. GLAZING IN GUARDRAILS
8. GLAZING LESS THAN 16' ABOVE FINISHED FLOOR
9. STAIRWAYS, LANDINGS d RAMPS WITHIN 36' HORIZONT -AL OF WALKING
SURFACE AND SO' ABOVE ADJACENT WALKING 5URFACE
MEG-IANICAL
HEATING EQUIPMENT
ALL WARM -AIR FURNACES SHALL BE LISTED AND LABELED BY AN APPROVED AGENCY AND
INSTALLED TO LISTED SPECIFICATIONS.
NO WARM -AIR FURNACES SHALL BE INSTALLED IN A ROOM USED OR DESIGNED TO BE USED
AS A BEDROOM, BATHROOM, CLOSET OR IN ANY ENCLOSED SPACE WITH ACCESS ONLY
THROUGH SUCH ROOM OR SPACE, EXCEPT DIRECT VENT FURNACE, ENCLOSED FURNACES
AN ELECTRIC HEATING FURNACES.
LIQUEFIED PETROLEUM GAS - BURNING APPLIANCES SHALL NOT BE INSTALLED IN A PIT.
BASEMENT OR SIMILAR LOCATION WHERE HEAVIER THAN AIR GAS MIGHT COLLECT.
APPLIANCES 50 FUELED SHALL NOT BE INSTALLED IN AN ABOVE GRANDE UNDER FLOOR
SPACE OR BASEMENT UNLESS SUCH LOCATION 15 PROVIDED WITH AN APPROVED MEANS
FOR REMOVAL OF UNBURNED GAS.
HEATING AND COOLING EQUIPMENT LOCATED IN A GARAGE AND WHICH GIFNERATES A GLOW,
SPARK OR FLAME CAPABLE OF IGNITING FLAMMABLE VAPORS SHALL BE INSTALLED WITH
THE PILOTS AND BURNERS OR HEATING ELEMENTS AND SWITCHES AT LEAST IS'
ABOVE THE FLOOR LEVEL.
TEMPERATURE CONTROL
THE PRIMARY SPACE OONDITIONNG SYSTEM WITHIN
EACH DWELLING UNIT SHALL BE PROVIDED WITH AT
LEAST ONE PROGRAMMABLE THERMOSTAT FOR
THE REGULATION OF TEMIFERTURE W5EG SEC. 503,5.1
VENTILATION
GROUP R OCCUPANCIES SHALL BE PROVIDED WITH VENTILATION
SYSTEMS WHICH COMPLY WITH THE SECTION 1115055 OF THE 2009
IRC AND WASHINGTON STATE AMENDMENTS.
MINIMUM SOURCE- SPECIFIC VENTILATION 15 REQUIRED IN THE FOLLOWING LOCATIONS
AND AS OTHERWISE SPECIFIED:
A. BATHROOMS: 50 cfm
B. LAUNDRIES: SO cfm
C. WATER CLOSETS: 50 cfm
D. KITCHENS: 100 cfm
EVERY FACTORY BUILT CHIMNEY, TYPE L VENT, TYPE B GAS VENT OR TYPE BW GAS
VENT SHALL BE INSTALLED IN ACCORDANCE WITH THE TERMS OF ITS LISTING,
MFR'S INSTALLATION INSTRUCTIONS AND APPLICABLE CODE REQUIREMENTS.
A TYPE L VENTING SYSTEM SHALL TERMINATE NOT LE55 THAN 2 FEET ABOVE THE HIGHEST
POINT WHERE THE VENT PASSES THROUGH THE ROOF OF THE BUILDING AND AT LEAST
2' HIGHER THAN ANY PORTION OF THE BUILDING WITHIN 10' OF THE VENT.
INTEGRATED 24 HR WHOLE HOUSE VENTILATION SYSTEM SEC MI508.1
• INTEGRATED WHOLE HOUSE VENTILATION 5Y5YEM5 SHALL PROVIDE OUITSIDE AIR AT THE RATE USING
SECTION M15083. INTEGRATED FORCED -AIR VENTILATION SYSTEMS SHAILL DISTRIBUTE OUTDOOR AIR
TO EACH HABITABLE ROOM THROUGH THE FORCED AIR SYSTEM DUCTS.
• USING A SUPPLY FAN W/ MANUAL d MOTORIZED DAMPER
• FAN TIMER EXTERNALLY LOCATED ON THE SIDE OF FURNACE.
220 CFM REQUIRED W/ A RUN TIME OF 8 HRS. MIN.
FAN MUST OPERATE AT LEAST ONCE EVERY THREE
HOURS SO VENTILATION EFFECTIVENESS CAN BE 1.0
• 8' SMOOTH WALL PIPE
(OPERATION DESCRIPTION TO BE PROVIDED PER M1508)
SYSTEM TO BE TESTED AT FINAL INSPECTION d LABELED
UTILTY ROOM NOTE5/MAKE UP AIR:
DRILLING AND NOTGHINCs STUDS.
DRILLING AND NOTCHING STUDS. PER SEC R602b
DRILLING AND NOTCHING OF STUDS SHALL BE IN ACCORDANCE WITH
THE FOLLOWING:
NOTCHING. ANY STUD IN AN EXTERIOR WALL OR BEARING PARTITION
MAY BE OUT OR NOT14CED TO A DEPTH NOT EXCEEDING 25 PERCENT
OF ITS WIDTH. STUDS IN NONBEARING PARTITIONS MAY BE NOTCHED
TO A DEPTH NOT TO EXCEED 40 PERCENT OF A SINGLE STUD WIDTH.
Z DRILLING. ANY STUD MAY BE BORED OR DRILL VI
ED, PROVIDED TWAT
THE DIAMETER OF THE RESULTING HOLE IS NO MORE THAN 60 PERCENT
THE HOLE IS NO MORE THAN 5'e INCH (16mm)
OF THE STUD WIDTH, THE EDGE OF
TO THE EDGE OF THE STUD, AND THE HOLE IS NOT LOCATED IN THE SAME
SECTION AS A CUT OR NOTCH. STUDS LOCATED IN EXTERIOR WALLS OR
BEARING PARTITIONS DRILLED OVER 40 PERCENT AND UP TO 60
PERCENT SHALL AL50 BE DOUBLED WITH NO MORE THAN TWO SUCCESSIVE
DOUBLED STUDS BORED. SEE FIGURES 02b(U AND R602b(2).
- EXCEPTION: USE OF APPROVED STUD SHOES IS PERMITTED WHEN THEY
ARE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S
RECOMMENDATIONS.
DRILLING AND NOTCHING OF TOP PLATE. PER SEC R602,51
WHEN PIPING OR DUCTWORK IS PLACED IN OR PARTLY IN AN EXTERIOR
WALL OR INTERIOR LOAD BEARING WALL, NECESSITATING CUTTING, DRILLING
OR NOTCHING OF THE TOP PLATE BY MORE THAN 50 PERCENT OF ITS WIDTH,
A GALVANIZED METAL TIE OF NOT LESS THAN 0.054 INCH THICK (131mm) 06 2a)
AND 1112 INCHES (38mm) WIDE SHALL BE FASTENED ACROSS AND TO THE PLATE
AT EACH SIDE OF THE OPENING WITH NOT LESS THAN EIGHT 16d NAILS AT
EACH SIDE OF EQUIVALENT. SEE FIGURE bR 02b.11.
- EXCEPTION: WHEN THE ENTIRE SIDE OF THE WALL WITH THE NOTCH OR CUT IS
COVERED BY WOOD STRUCTURAL PANEL SHEATHING
INSPECTIONS AND ENFORCEMENT
POSTING OF CERTIFICATE WSEC 1054
A PERMANENT CERTIFICATE SHALL BE POSTED WITHIN THREE FEET OF
THE ELECTRICAL DISTRIBUTION PANEL. THE CERTIFICATE SHALL BE
COMPLETED BY THE BUILDER OR REGISTERED DESIGN PROFESSIONAL.
THE CERTIFICATE SHALL LIST THE PREDOMINANT R- VALUES OF
INSULATION INSTALLED IN OR ON CEILING/ROOF, WALLS, FOUNDATION
(SLAB, BASEMENT WALL, CRAIId_SPACE WALL AND /OR FLOOR), AND
DUCTS OUTSIDE THE CONDITIONED SPACES, U- FACTORS FOR
FENESTRATION, AND THE SOLAR HEAT GAIN COEFFICIENT (SHGC) OF
FENESTRATION. WHERE THERE IS MORE THAN ONE VALUE FOR EACH
COMPONENT, THE CERTIFICATE SHALL LIST THE VALUE COVERING THE
LAIYiEST AREA. THE CERTIFICATE SHALL LIST THE TYPE AND
EFFICIENCY OF HEATING, COOLING, AND SERVICE WATER HEATING
EQUIPMENT, DUCT LEAKAGE RATES INCLUDING TEST CONDITIONS AS
SPECIFIED IN SECTION 503.101, AND AIR LEAKAGE RESULTS IF A
BLOWER DOOR TEST WAS CONDUCTED.
DUCT LEAKAGE TESTING: DUCTS SHALL BE LEAK TESTED IN
ACCORDANCE WITH R5 -33, USING THE MAXIMUM DUCT LEAKAGE
RATES SPECIFIED IN 2009 Wl9EC SEC. 503.103
HVAC DUCTS MAY NOT DISPLACE REQUIRED INSULATION
AND BUILDING CAVITIES MAY NOT BE USED AS DUCTS
PER 503.10.1 WSEC
BUILDING AIR LEAKAGE TESTING 2009 W5EC SEC. 502.45
TESTING SHALL OCCUR AT ANY TIME AFTER ROUGH IN AND AFTER
INSTALLATION OF PENETRATIONS OF THE BUILDINCs ENVELOPE.
WHEN IREDE ENE IOFAIESF TE CONDUCTED IN PRESENCE DEPARTMENT H BLOWIER
DOOR TEST RESULTS SHALL BE RECORDED ON THE CERTIFICATE
REQUIRED IN SEC. 105.4.
LIGHTING
W5EC SECTION 505
505.1 INTERIOR LIGHTING: A MINIMUM OF 50 PERCENT OF ALL
LUMINAIRES SHALL BE HIGH EFFICACY LUMINAIRES.
- EXCEPTION. LIGHTING THAT COMPLIES WITH THE PRESCRIPTIVE
LIGHTING OPTION IN SECTION 1520 OR THE LIGHTING POWER ALLOWANCE
OPTION IN SECTION 1530.
5052 /*5053 EXTERIOR LIGHTING: LUMINAIRES PROVIDING OUTDOOR
LIGHTING AND PERMANENTLY MOUNTED TO A RESIDENTIAL BUILDING OR
TO OTHER BUILDINGS ON THE SAME LOT SHALL BE HIGH EFFICACY
LUMINAIRES.
- EXCEPTIONS, U PERMANENTLY INSTALLED OUTDOOR LUMINAIRES THAT
ARE NOT HIGH EFFICACY SHALL BE ALLOWED PROVIDED THEY ARE
CONTROLLED BY A MOTION SENSOR(5) WITH INTERRALt
PHOTOCONTROL PHOTOSENSOR, 2) PERMANENTLY INSTALLED
LUMINAIRES IN OR AROUND SWIMMING POOLS, WATER FEATURES.
5053 LINEAR FLUORESCENT FIXTURES: LINEAR FLUORESCENT FIXTURES
MUST BE FITTED WITH T -8 OR SMALLER LAMPS (BUT NOT T -10 OR T -12
LAMPS).
STAIRWAY ILLUMINATION PER SEC 303b IRC
ALL INTERIOR AND EXTERIOR STAIRWAYS SHALL BE
PROVIDED WITH MEANS TO ILLUMINATE THE STAIRS,
INCLUDING THE LANDINGS AND TREADS. INTERIOR
STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT
SOURCE LOCATED IN THE IMMEDIATE VICINITY OF EACH
LANDING OF THE SYAIRWAY.
EXTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL
LIGHT SOURCE LOCATED IN THE IMMEDIATE VICINITY OF THE
TOP LANDING OF THE STAIRWAY.
I__ -.. I . &...
I. WHERE THE EXHAUST DUCT IS CONCEALED WITHIN
THE BUILDING CONSTRUCTION, THE EQUIVALENT
� REFER O PLAN FOR OP I ON J E L E CT I OV
ALL GLAZING TO BE IN COMPLIANCE WITH THE LATEST
LENGHT OF THE EXHAUST DUCT SHALL BE IDENTIFIED
ON A PERMANENT LABEL OR TAG. THE LABEL OR TAG
SHALL BE LOCATED WITHIN 6 FEET OF THE EXHAUST
DUCT CONNECTION.
WASHINGTON STATE ENERGY CODE. TOTAL GLAZING
AREA AS 0 % OF GROSS FLOOR AREA = WINDOW AREA/FLOOR AREA= %
OPTION
AREA
GLAZING U -FACTO
D
U -F i
�
CEILING
V�
C E LNG
WALL
GRADE
-INi.WALL-EXT.
�♦� 1:4
FL
S A
C ON
2. INSTALLATIONS EXHAUSTING MORE THAN 200 CFM
SHALL BE PROVIDED WITH MAKE UP AIR WHERE A
CLOSET 15 DESIGNED FOR THE INSTALLATION OF A
BEL
GSA E
OF FLOOR AREA
VERTICAL
OVERHEAD
a
1
13%
034
050
010
ur 8-39
R -38
R -21
INT
R -21
R -30
R -10
y
CLOTHES DRYER AN OPENING HAVING AN AREA OF
NOT LESS THAN 100 SQ. INCHES FOR MAKE UP AIR
SHALL BE PROVIDED IN 714E CLOSET ENCLOSURE, OR
MAKE UP AIR SHALL BE PROVIDED BY OTHER APPR
MEANS.
®= 100 5Q INCH TRANSFER GRILL PER IMG 5045
II
25%
032
050
020
-
R -38
R-21
R -21
R -I0
R -30
R -10
III
UNLIMITED
030
050
010
9
a 8,38
R-�
8`21
R -21
R -10
-30
R-10
O tu
M
W 0
[ iMt
N�-
Z
4
tu
a
1. Contractor or builder
mwt verify ell dimensions
before proceeding with
construction.
2. This plan sae designed
to be marketed throughout
many muticipahties. The
purcbaser must verify
compliance with an local
applicable building codes
where the home is to be
constructed.
a. purchaser should have
pbum reviewed by a He-
eased builder sad strwt-
oral engineer for compli-
... to specific site a.,
ditions.
4. These plans should not
be altered by other then a
qualified designer, arcbi-
teef, or structural engineer.
Plan No:
Date:
2011
N -1
Z
E�
V!
W
C ptr
.•. z
us
�♦� 1:4
E
V
N
a
l
O tu
M
W 0
[ iMt
N�-
Z
4
tu
a
1. Contractor or builder
mwt verify ell dimensions
before proceeding with
construction.
2. This plan sae designed
to be marketed throughout
many muticipahties. The
purcbaser must verify
compliance with an local
applicable building codes
where the home is to be
constructed.
a. purchaser should have
pbum reviewed by a He-
eased builder sad strwt-
oral engineer for compli-
... to specific site a.,
ditions.
4. These plans should not
be altered by other then a
qualified designer, arcbi-
teef, or structural engineer.
Plan No:
Date:
2011
N -1
WEATHER RESISTANT
BARRIER OVER
SHEATHING OR SUBSTRATE
FINISH SIDING
05M TRIM FLASHING WITH
5" MIN. VERTICAL LEO
IORIZONTAL WOOD TRIM
HORIZ. TRIM vtUDep
N.TS.
12
51
12
�8
REAR ELEVA71 0N
1/4" =1' -O"
12
1e
2x6 EXTERIOR WAL
1/16' PLY OR 095
SHEATHING, TYP.
SIDING PER ELEVA
OVER VAPOR BARB
PRE- FINISHED CON
5HEETMETAL FLASF
COMP. ROOFING 0%
BARRIER ATOP 1 /1,
065 SHEATHING, T1
TRUSS OR RAFTER PER PLAN
ROOF t0 L4LL FLl4&HINCx DEt411e.
N.T.S.
[I]
[0-1 ' �� m N
R16H7 EL EVA7I ®N
1/4" =1' -O"
12
5/4x8 BAND 517.
W/ FLASHING
�o
AQ
Vf4x10 BAND BD.
Yl/ FLASHING
5/4x4 WINDOW , DOOR
6 CORNER TRIM ® SIDES
AND REAR ELEV'S
6A5LE END VENTS
COMP ROOF
B66 SIDIN6
5/4x8 BARGE W/
IX3 RAKE TRIM
5/4x6 WINDOW, DOOR
6 CORNER TRIM ® FRG
5/4x4 CORNER 517'5
6" EXP. HORIZ. SIDIN6-
5 /4x10 BAND
A/ FLASHIN6
CONT. &UTTER
MASONRY VENEER- GENERAL, NOTE
- MAXIMUM THICKNESS 5 INCHES 6 30 FEET HEIGHT.
- SDC DI 6 D2 MAXIMUM 4 INCHES THICK 6 MUST
HAVE WALL BRACING.
- NOT OK TO SUPPORT ADDITIONAL LOADS ON
MASONRY VENEER.
- MINIMUM 3/4 GAP BETWEEN TOP OF VENEER 6
STRUCTURAL FRAME INCLUDING ROOF RAFTERS.
- METAL TIES MAXIMUM 24 INCHES HORIZONTAL 6
VERTICAL SPACING.
- TIES IN 50C DI d 02 MUST SUPPORT NO MORE THAN
2 SQ FT OF WALL AREA (HOOK INTO VENEER
REINFORCEMENT WIRE.
- FLASHING TO EXTERIOR REQUIRED AT ALL
OPENINGS 6 HORIZONTAL TRANSITIONS.
- MINIMUM 3116 INCH WEEPHOLES REQUIRED ABOVE
FLASHING MAXIMUM 33 INCHES ON CENTER
- AIR SPACE MINIMUM I INCH - MAXIMUM 4 12 INCHES
BETWEEN SHEATHING t VENEER OR MORTAR OR
GROUT FILL OVER WEATHER - RESISTANCE MEMBRANE.
- WATER RESISTANT BARRIER REQUIRED
BEHIND THE EXTERIOR VENEER PER R1032
LEFT ELEVA710N
e 12
PJ
12
15
6
GRADE TO SLOPE AAAY —
FROM POUNDATION A MIN.
OP 6" WITHIN THE FIRST 10'
FR®N7 ELEVA71CN
1/4 "= I' -O"
OL
0=
J Uj
W�Q
�N
W
m2
m!
F=
I
m
Ow=
O =�
IL
?NQ
IW
sm_
v0
0 j
„r
HOUSE NUMBERS TO BE VISIBLE 6
LEGIBLE WITH CONTRASTING
BACKGROUND FROM THE STREET
FRONTING THE HOUSE.
ADDRESS NUMBER SHALL B£ MIN,
4' HIGH t A MIN. STROKE WIDTH OF
12' PER SEC. 8319.1
r—, a
A ap m
A
z
V
w
ti
O
a
w
N
z
w
A
w
w
1. Contractor or builder
must verity all dimaneiom
before proceeding with
comlructic .
2. Thie plan wee designed
to be marketed throughout
many n u d.ipalitiee. The
purchaser must verity
compliance with all local
applicable building cede.
where the home 6 W be
conetrueted.
3. Purchaser .hould have
elaue reviewed by a lic-
mad builder and struct-
ural eugiueer for compli-
ance to specific site con-
dition..
4. These plaus should not
be altered by other then a
qualified designer, archi-
tect, or structural engineer.
Plan No:
L2B -1809
12 -26 -12
11
4' MM
2' MN
MUM
2 -1/4' m X 5' LAG SCREWS
• STUD WALL
2 -3/8' m X 5' BOLTS
W/ 51 VC6 ADHESIVE
• CONC WALL
16 GA STEEL STRAPPING
ARpUNp WATER HEATER
W THI IN 1HE UPPER LAM
ONE -THIRD OF THE APPL.
r A MIN OF 4' FROM CONTROLS
HOLD WATER HEATER
TIGHT TO GM • BACK
FLEXIBLE WATER CONNECTIONS
2X4 LEDGER
PREWWRE TREATED
e GONG WALL
16 GA STEEL STRAPPING
A WATER HEATER
W THM THE UPPER r LOVER
ONE -THIRD OF THE APPL.
1 A MIN OF 4' FROM CONTROLS
'LEXIBLE GAS CONNECTION
ANCHOR WA TO BASE -
EASE TO FLOOR
NO SCALE
rrslplildk
6' -0'
4'-31' I' -8} 5' -6' S' -6' 6' -0 }' 6' -II }•
'101 /0 XO
X GO ERED
p 9 PORCH p
cc NC.
x 0 d
3/0x4/ XO A\ 6 /0x8 /0 SGD S.G. r.
DINING ROOM
9 CG.
S
Z �
QR MANUF. GAS 2'-0'
METAL FIREPLACE
SINK O m INSTALL PER MFR
100 CFM (K SPECS.
a VEOF. — GREAT ROOM
'n Q DW j Lu LL 9' GLG. 0
KITCHEN
S.
NO CT OPENI 5 ®�
IN GADU
RAGE. REFE ��
DUCTS THROUGH CL OR
WALL COMMON TO HOUSE,
MIN. 26 GAGE STEEL. _ PNTR.
R R3 N ,
v 13V MIN. SOLID CO 4' G TYPIL v
0 WOOD,STEEL DOOR G
m 20 MOR
10' -0' ? II'_6 • WHo 4'_3' _ 4, -9• 5'_2 }• _
R \\ B.r L)
USE 1/2' T 'X _L AND T % E IZ / ENTRY H I =
6F ENTO
S U WAI L5. lU \FIR ......�. TYPE 4 31 URN. to -\� ~
ON E PA�� x, • ABOVE O E IL Q
AND B AM _� B VEHICLE IMPACT ��y
BARRIER k1d UP 16 R
NOTES PWDR. �`JJJ ® r�
- PROVIDE EXPANSION TANK 9' GLG.\ /���J r 2/0x /0 FX
- PROVIDE SEISMIC STRAPPING E,F ' L O
- TPRV TO TERT11NATE TO OUTSIDE 50 CFM _
N
-PILOT 1 CONTROLS 2/0x 0 FX
TO BE 18' MIN.
OFF FLOOR PLR LN ABOVE
- PER ASH RAE COVERED
90 -A -50 PORCH B
GONG. N
16/0 8/0 O.H. DOOR 16' -3' R.O.
LANDING AT 'EXIT' DOOR
I' -10 }' 2' -10 NOT TO BE LOWER THAN
3' -0' 16' -0' 3' -0' 2'-g }� 3' -3' } �'_3. 15 INCHES FROM TOP OF
22' -0' 6' -0' 12' -0' THRESHOLD. (83113.1)
40' -0'
BLUE 18 AWG TRACER
WIRE REQUIRED D NON-
METAL O
PIPING PER UPC 604.8.
MAIN FLOOR PLAN
/4 "= I ' -O"
WASHINGTON STATE ENERGY CODE. TOTAL GLAZING
AREA AS A96 OF GRO58 FLOOR AREA = 261/1809 =14.43 %
TI
MAIN FLOOR:
-765
50.
F:T.
UPPER FLOOR:
1041
5O.
PT.
TOTAL:
ISOli
SO.
FT.
GARA63 =:
553
50.
PT.
COPYRIGHT 2009
Landmark Design Inc.
ALL RIGHTS RESERVED
STAIRWAY ILLUMINATION PER SEC 303.6 IRC
ALL INTERIOR AND EXTERIOR STAIRWAYS SHALL BE
PROVIDED WITH MEANS TO ILLUMINATE THE STAIRS,
INCLUDING THE LANDINGS AND TREADS. INTERIOR
STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT
SOURCE LOCATED IN THE IMMEDIATE VICINITY OF EACH
LANDING OF THE SYAIRWAY,
EXTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL
LIGHT SOURCE LOCATED IN THE IMMEDIATE VICINITY OF TN5
TOP LANDING OF THE STAIRWAY.
ALL GLAZING TO BE IN COMPLIANCE WITH THE LATEST
WASHINGTON STATE ENERGY CODE. TOTAL GLAZING
AREA AS A96 OF GRO58 FLOOR AREA = 261/1809 =14.43 %
TI
GAZM AREA %
G A INS U -F T
C I
VAULTED
WALL
M
XT
FL
S
ON
I
OF FLOR AREA
VRICAL
OvER1D
N
C I
m�
992E
I
13%
034
050
020
aR.�
R -38
R -21
R -21
R -10
R -30
R -10
ADY
INT
2'
II
25%
037
050
070
R-
X21
R -21
R -10
R -30
Rj10
III
UNLIMITED
030
050
020
aR4
R -38
R -21
R -7I
R -10
OID�e
R 10
2
GENERAL NOTES:
... F. -1. ...
I. ALL WORK TO BE IN CONFOFa IANCE WITH 2009 IRC.
2. VENT ALL EXHAUST FANS, DRYER VENTS AND
RANGES TO OUTSIDES.
3. VENT WATER HEATER PRESSURE RELIEF VALVES
TO OUTSIDE.
4. PROVIDE FIRE BLOCKING AT ALL PLUMBING AND
MECHANICAL PENETRATIONS.
S. ALL SHOWER WALLS TO BE WATERPROOF TO
MINIMUM 12' ABOVE DRAIN.
6. SHOWER TO BE LIMITED TO MAXIMUM 2.5 G.P.M. FLOW.
T. ALL GLAZING WITHIN 60' ABOVE DRAIN INLET TO
BE SAFETY GLASS.
8. ALL GLAZING WITHIN 24' OF DOOR OR WITHIN IS'
OF: FLOOR TO BE SAFETY GLA55
9. SMOKE DETECTORS TO BE INSTALLED PER SEC 83143
IN THE FOLLOWING LOCATONS: IN EACH SLEEPING ROOMS,
OUTSIDE EACH 5EPERATE SLEEPING AREA IN THE
IMMEDIATE VICINITY OF THE BEDROOMS.
ON EACH ADDITIONAL STORY OF THE DWELLING,
INCLUDING BASEMENTS AND HABITAL ATTICS.
ALAp'TS TO BE INTERCONNECTED IN SUCH A MANNER
THAT ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF
THEE ,,ALARMS IN THE INDIVIDUAL UNIT.
ED =SMOKE ALAW- CARBON MONOXIDE COMBO.
CM-
10. PROVIDE CARBON MONOXIDE ALARMS PER SEC. 315.1
AN APPROVED CARBON MONOXIDE ALARM SHALL BE
INSTALLED OUTSIDE OF EACH SLEEPING AREA IN THE
IMMEDIATE VICINITY OF THE BEDROOMS.
PER 2009 IRC / WA. STATE AMENDMENTS SEC 83151
INSULATE ALL WATER PIPES PER UPC SEC 313.6
MINIMUM R -3 INSULATION
12. FLEX GAS PIPING IS TO BE PROTECTED PER G2415.5,
PIPING SHALL BE PROTECTED W/ No 16 GAGE STL. SHIELD PLATES
PLATES SHALL COVER THE AREA OF THE PIPE WHERE THE MEMBER
IS NOTCHED OR BORED AND SHALL EXTEND A MIN. OF 4' ABOVE
SOLE PLATES, BELOW TOP PLATES AND TO EACH SIDE OF A STUD,
JOIST OR RAFTER
13. ATTIC 4 CRAWL ACCESS HATCHES OR DOORS SHALL
BE WEATHERSTRIPPED AND INSULATED TO A LEVEL
EQUIVALENT TO THE INSULATION ON THE SURROUNDING SURFACES
14. WHOLE HOUSE VENTILATION 24 NR
TIMER, READILY ACCESSIBLE t
WITH LABEL AFFIXED TO CONTROL
THAT READS 'WHOLE HOUSE VENTILATION'
(SEE OPERATING INSTRUCTIONS)
zH
0
.�
�
�
5
k
zf
♦♦♦
no
�
<831
v zd
N
1. Contractor or builder
moat verify ea dbnenione
befaN proceeding with
construction.
2. This plan wee designed
to be nurketed throughout
meny muWcipeaties. The
purchaser moat aerlfy
compaence with all local
wpplfceble buildivg codes
here the home m
to be
constructed.
3. Purcheaer should bave
plena reviewed by a lic-
emed builder end e1,ruct-
.1 engineer for compli-
ance W apecmc Bite con-
dition.
4. These plan should not
be altered by other then e
quelined designer, archi-
tect or structural engineer.
Plan No:
L2B -1809
Date:
12 -26 -12
0!
(6)
Sr:GONr; ®
t -10 RI&ID INSULATION
I EXTERIOR SIDE OP WALL
5HADED AREA)
FRAMING NOTES:
L ALL MULTIPLE JOISTS OR BEAMS MUST BE BOTH
KsLUED AND NAILED W1 8d NAILS a 24' O.C.
NAILED TOP 4 BOTTOM STAGGERED EA SIDE.
2. ALL HEADERS TO ISE 48 OF n UNLESS NOTED
OTHERWISE. T
RO ID INSULATION TO
B&TAED U RRGI
3. )SOLID BLOCK BENEATH ALL POINT LOADS FROM
ABOVE.
I
FOUNDATION NOTES:
I. ALL FOOTINGS TO BEAR ON FIRM) UNDISTURBED
SOIL.
2. ALL WOOD IN CONTACT WITH CONCRETE TO BE
PRESSURE TREATED.
3. ALL BEAMS TO BE 4x10 DFL"2 ON 4x4
POSTS (4x6 AT SPLICES) ON 24' DIA.
x 8' GONG. PADS UNLESS NOTED
OTHERWISE.
4. ALL POSTS TO BE ANCHORED AGAINST
LATERAL MOVEMENT.
�®UNr;�A�I ®N FLAN
1/4.1=11-0"
STHD EDGE DISTANCE 1 -V2' MIN
BUILDER TO DETERMINE IF STHD OR STHD)RJ IS AF'PROF'RIATE.
12' MINIMUM AWAY FROM HOLDOWNS
COPYRIGHT 2007
Landmark Design Inc.
ALL RICSMTS RESERVED
4' 0 SCHED. 40 $%. BOLFARD
4x4 P.T. POST
W) PB BASE
ON 24'x24'xl2'
CONCRETE FTG.
(2 PLACES)
zy
A aZ
U *j
vz
1. Contractor or builder
must verity an dimensions
R -10 R1610 INSULATION
0 EXTERIOR SIDE OF MALL
(SHADED AREA)
HF.Ar; iER INSULA710N r;�F_�AI
NTS
ST W/
PB BAOE
ROOF FRAM I NIS FLAN
PT P054 W/
CAP 1 P°B BASE ROOF FRAMING NOTES:
OF 2)
I. ALL HEADERS TO BE 48 DF •2 UNLESS
NOTED OTHERWISE.
HEADERS AT EXTERIOR WALLS t WART WALLS TO
BE INSULATED W/ R -10 RIGID INSULATION
2. ALL OTHER TRUSSES:
• SHALL CARRY MANUFACTURERS STAMP.
SHALL HAVE DESIGN DETAILS AND SPEC-
IFICATIONS ON SITE FOR FRAME INSPECTION.
• SHALL BE INSTALLED AND BRACED PER
MANUFACTURERS SPECIFICATIONS,
3. NO TRUSS SHALL BE FIELD - MODIFIED WITHOUT
PRIOR CONSENT OF THE TRUSS ENGINEER AND
THE BUILDING DEPARTMENT.
4. PROVIDE ATTIC ACCESS MINIMUM 22'x30' PER
IRC SEC 801.1
• ACCESS HATCHES OR DOORS SHALL
BE WEATHERSTRIP'PED AND INSULATED TO A LEVEL
EQUIVALENT TO THE INSULATION ON THE SURROUNDING SURFACES
5. PROVIDE ATTIC VENTILATION PER IRC SECTION
Ra06. ALL FRAMING TO COMPLY WITH IRC SECTION 8602.
NAIL SIZE AND SPACING TO CONFORM TO IRC SECTION
8602, TABLE 86023.
6. aA REFER TO SHEAR WALL SC14ED.
• 0
A H"
d' ! z6
1. Contractor or builder
moat verify ell dimewlc®
before proceeding with
constructtnv.
2. This pbm was deaigmd
to be marketed throughout
many muoicipabties. The
purchaser must verity
compliance with ell local
applicable building codes
where the home Is to be
constructed.
3. purchaser abould have
plam reviewed by a ho-
emed bolder and struct-
ure] engineer for compli-
ance to specific site con -
diticm.
a. These plane shoWd not
be altered by other tbrn e
quoUfted designer, archi-
tect. or structural engineer
Plan No:
L2B -1809
Daft
12 -26 -12
v
3) 2x6
END TRUSS
8
12
ANF. TRUSSES
8
a 24' O.G. 12 1
12 W
W
X O
U
MANE. TRUSSES
END S
S
n
n y
y o
o 24' O.C.
12 1
12 y
. 1
S2ID X
1.
- ;
_ 1
X 1
12
ROOF FRAM I NIS FLAN
PT P054 W/
CAP 1 P°B BASE ROOF FRAMING NOTES:
OF 2)
I. ALL HEADERS TO BE 48 DF •2 UNLESS
NOTED OTHERWISE.
HEADERS AT EXTERIOR WALLS t WART WALLS TO
BE INSULATED W/ R -10 RIGID INSULATION
2. ALL OTHER TRUSSES:
• SHALL CARRY MANUFACTURERS STAMP.
SHALL HAVE DESIGN DETAILS AND SPEC-
IFICATIONS ON SITE FOR FRAME INSPECTION.
• SHALL BE INSTALLED AND BRACED PER
MANUFACTURERS SPECIFICATIONS,
3. NO TRUSS SHALL BE FIELD - MODIFIED WITHOUT
PRIOR CONSENT OF THE TRUSS ENGINEER AND
THE BUILDING DEPARTMENT.
4. PROVIDE ATTIC ACCESS MINIMUM 22'x30' PER
IRC SEC 801.1
• ACCESS HATCHES OR DOORS SHALL
BE WEATHERSTRIP'PED AND INSULATED TO A LEVEL
EQUIVALENT TO THE INSULATION ON THE SURROUNDING SURFACES
5. PROVIDE ATTIC VENTILATION PER IRC SECTION
Ra06. ALL FRAMING TO COMPLY WITH IRC SECTION 8602.
NAIL SIZE AND SPACING TO CONFORM TO IRC SECTION
8602, TABLE 86023.
6. aA REFER TO SHEAR WALL SC14ED.
• 0
A H"
d' ! z6
1. Contractor or builder
moat verify ell dimewlc®
before proceeding with
constructtnv.
2. This pbm was deaigmd
to be marketed throughout
many muoicipabties. The
purchaser must verity
compliance with ell local
applicable building codes
where the home Is to be
constructed.
3. purchaser abould have
plam reviewed by a ho-
emed bolder and struct-
ure] engineer for compli-
ance to specific site con -
diticm.
a. These plane shoWd not
be altered by other tbrn e
quoUfted designer, archi-
tect. or structural engineer
Plan No:
L2B -1809
Daft
12 -26 -12
v
STAIR NOTES:
STRINGERS TO BE NRE BLOCKED AT BOTH TOP AND
BOTTOM.
ALL USABLE SPACE UNDER STAIRS TO BE 1 HOUR
CONSTRUCTION.
• MAXIMUM RISE TO BE 7 -3/4.
• MINIMUM RUN TO BE 10'.
• MINIMUM HEAD HEIGHT TO BE 6' -B'.
' MINIIMUM STAIR WIDTH TO BE 36'.
P PROMDE CONTINUOUS HAND RAIL 34' TO 38' OFF
TREAD NOSING AND MUST EXTEND BEYOND BOTTOM
TREAD.
• PROMDE GUARD RAILS AT LANDINGS MINIIMUM 36'
HIGH W/ CLEAR SPACE
s HANDGRIP PORTION OF HANDRAIL SHALL BE
NOT LESS 1 1/4' NOR MORE THAN 2' IN
CROSS SECTIONAL DIM.
WINDING STAIRS
PER CURRENT I.B.C.
SPIRAL STAIRS
PROMDE MIN 7 1/2' RUN 0 A POINT 12'
FROM WHERE TREAD IS NARROWEST
PER CURRENT I.B.C.
W MERE SMALL -
M PAM TIR:TY,JI
I T. HANDRAIL 34• -38'
ABOVE TREAD NOSMG.
PICKETS, PER IRC 312J
ON OPEN SIDE
r PT RISERS
P.T. 2X12
F1
HL 35 ANGL1
_I TYPICAL STAIR DETAIL AN]
m Ba-
(mlm) to PAM TMCTIGM.
t0 PAM TNRLUiH GTBIBI'a
5BLae erase MTAH. k•
GM a COLBCA O nAile
TO WLLLB AdLONG AfID NLNi
YIIH S, RYf%F Af£A IlDS,2
wpNeT NOGG S1AIF8 M MiMBiED
INTERIOR
DECK
JOISTS FER PLAN
DBL JST
3 -2X12 P.T. STRINGERS
AF50 ROOF VENTS (50 5O. IK NET FREE AREA)
EVERY 3RD TRUSS BAY
SOLID TIGHT FITTMG
TRJSS 51 -00<1 G
FASCIA BOARD
2. STUDS PER PLAN
1 - SHEATHING
SIDMG PER PLAN
im
AF50 ROOF VENTS l50 SO. N. NET FREE AREA)
EVERY SRO TRU&S BAY
SOLID TIGHT FITTING
MISS BLOCKING
SFIA BOAR�STIVE TREATED
GYPSUM WALLBOARD GYPSUM SHEATHING WOOD STUDS "-
EXTERIOR % g VI :
I' III 0
'IORSDEO y JB J µ
J2J ql 1 '.I1 II
-1 er UI IU —Jq, G 1 J 14W 9 L.'l11
YfzsJ E I JJ g I _ 1 9 J
INTERIOR S1DE a I r I I" 'y 11161c ."I p I e� _
bmrJ gyp 10-101 t—,, pled P-111 urn. 1,1 9lis on. eca-11, 61=2
_1l Pli 1009.00915. 11a"k'. "Hea(JS.7 0c (LOADGEARINGI
2x STUDS, PER PLMJ
SIDING PER PLAN
5/8' SHEETROCK
ss
Alp Wep41
1,1
FJa real
ri"Te
ILL R35 ' 4l
ILL R350 9.O 65.
U1.I
UL Dasi19139
ULR1319 -119. 7 'P290.
UL D_', U ?1Q
5U 1 Lr;) 1 NCB 5EC71 ®N A
S /811 =11 -011
EVELS
EDING
ALEC)
i9
VE
5 AT THE TOP
:5 UNDER
CABLES
ITH AN
°ASSAGE
1-4
VI
• � V *N
e
�� FC m
e , X
e..
�a
1. Contractor or builder
must verly aM dimemiom
before prsceeding with
construction.
2. This plan was designed
to be marketed throughout
many municipalities. The
purchaser moat verify
compliance with aM local
BURPS= buildhAg codes
where the home is to be
comtructed.
& Purchaser should have
plain reviewed by a Us-
emed builder and struct-
ure. engineer for compli-
ance to specific site con-
ditions.
4. These plem should not
be shared by other then s
qualified desigmr, archi-
tsci, or etructursl engineer.
Plan No:
L2B -1809
Date:
12-29,-12
6i
MAIN �21rs® ®R L C7F-% 1 CAS
114" =1' -O"
COPYRIGHT 2009
Landmark Design Inc.
ALL RIGHTS IMaERVED
ELECTRICAL KEY
OVERHEAD
CAN
f�l
OUTLET
DUPLEX OUTLET
$
220V OUTLET
COMBO. EXT. FAN
(VTOS) 4
LIGHT
COMBO SMOKE ALARM -
CARBON MONO. DET.
110 V !U/ BATTERY
C
BACKUP
GABLE T.V. JACK
PHONE
UNDER COUNTER
LIGHTS
V"C
GAS OUTLET
t
HOSE BIBS
4
EXT. FAN VTOS
0
rfH N
V W* e
Fi
1. Contractor or builder
mwl verity ell dimensions
be }ore proceeding with
construction.
2. Title plan wee designed
to be marketed threug ut
many muNClpehties. The
purchaser mwt verify
compliance with all local
applicable building codes
where the home is b be
constructed.
3. Purebaser should have
plans reviewed by a lic-
ewed builder end atruot-
urel engineer for compll-
snce to .pacific site con -
ditians.
d. These plane should not
be altered by other the. n
qualified designer, archi-
teot, or structural avgi.esr.
Plan No:
L2B -1809
Data
12 -26 -12
6
ENE FRAL &TFUCTUFRAL NOTES
ALL CONSTRUCTION SHALL BE IN CONFORMANCE WITH THE INTERNATIONAL BUILDING
CODE (IBC), 2009 EDITION, WITH WASHINGTON STATE AMENDMENTS.
DESIGN LOADS:
ROOF
LIVE LOAD
DEAD LOAD
FLOOR
LIVE LOAD
DEAD LOAD
25 P5F (SNOW)
15 PSF
40 P5F (RESIDENTIAL)
10 P5F
WIND
BASIC WIND SPEED 85 MPH (3 SECOND GUST)
EXPOSURE B, Iw = 10, K=, = 1.0
SEISMIC
EQUIVALENT LATERAL FORCE PROCEDURE
BEARING WALL SYSTEM (LIGHT- FRAMED WALLS)
51TE CLASS: D
SEISMIC DESIGN CATAGORY: D
55 = 1.5 - IBC FIGURE 1613.5(1)
Sips = 1.0, le = 1.0, R =65
Cs = 0.154
INSPECTIONS:
NO SPECIAL INSPECTIONS ARE REQUIRED. NOTIFY THE BUILDING DEPARTMENT FOR INSPECTIONS
REQUIRED BY LOCAL ORDINANCE. ALL PREPARED SOIL BEARING SURFACES SHALL BE
INSPECTED BY A SOILS ENGINEER PRIOR TO PLACEMENT OF REINFORCING STEEL.
FOUNDATIONS:
PLACE FOOTINGS ON NATIVE OR COMPACTED SOIL WITH 1,500 P5F BEARING CAPACITY (ASSUMED).
BOTTOM OF EXTERIOR FOOTINGS SHALL BE MINIMUM I' -6" BELOW OUTSIDE FINISHED GRADE.
BAGKFILL WALLS WITH A WELL DRAINING MATERIAL FREE OF ORGANIC OBJECTS OR DEBRIS.
CONCRETE:
THE SELECTION OF MATERIALS FOR AND THE MIXING AND PLACING OF ALL CONCRETE SHALL
CONFORM TO THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE, 2009 EDITION,
MATERIALS SHALL BE PROPORTIONED TO PRODUCE A DENSE, WORKABLE MIX HAVING A
MAXIMUM SLUMP OF 4 INCHES WHICH CAN BE PLACED WITHOUT SEGREGATION OR EXCESS FREE
SURFACE WATER. USE MINIMUM F'c = 3,000 P51 WITH 5.5 SACKS OF CEMENT PER CUBIC YARD OF
CONCRETE AND A MAXIMUM OF 5.2 GALLONS OF WATER PER 94 LB SACK OF CEMENT. ALL
CONCRETE SHALL CONTAIN AN AIR ENTRAINING AGENT. THE AMOUNT OF ENTRAINED AIR SHALL
BE 41/2% t1.I5 % BY VOLUME. MAXIMUM 51ZE OF AGGREGATE 15 11/2". ALL CONCRETE SHALL BE
POURED MONOLITHICALLY BETWEEN CONSTRUCTION OR EXPANSION JOINTS UNLESS SHOWN
OTHERWISE. CONCRETE PURVEYORS /SUPPLIERS DELIVERY OR BATCH TICKET TO BE ON JOB
SITE FOR BUILDING INSPECTOR VERIFICATION.
REINFORCING STEEL:
ALL ALL REINFORCING STEEL SHALL BE GRADE 40 (GRADE 60 IF NOTED) DEFORMED BARS IN
ACCORDANCE WITH 45TM SPECIFICATION A -615. LAP ALL SPLICES 32 BAR DIAMETERS OR I' -6"
MINIMUM UNLE55 OTHERWISE SHOWN. PROVIDE ELBOW BARS (32 DIA) TO LAP HORIZONTAL STEEL
AT CORNERS AND INTERSECTIONS IN FOOTINGS AND WALLS. REINFORCEMENT SHALL BE
ACCURATELY PLACED AND ADEQUATELY SUPPORTED BY APPROVED CHAIRS, SPACERS, OR
TIES AND SECURED IN PLACE DURING GROUT OR CONCRETE PLACEMENT.
MINIMUM CONCRETE COVER FOR REINFORCING STEEL:
USE PROTECTION
SLAB AND WALL BAR5:
INTERIOR FACES 112"
EXPOSED TO WEATHER OR EARTH 1112" (05 AND SMALLER)
2" (% AND LARGER)
FOOTING BARS 3"
TIMBER:
ALL LUMBER SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE:
BEAMS DFx2 OR BETTER
POSTS HF"2 OR BETTER
2x FRAMING HF12 OR BETTER
ALL 2x TIMBER SHALL BE KILN DRIED. ALL GRADES SHALL CONFORM TO "WWPA GRADING
RULES FOR WESTERN LUMBER ", LATEST EDITION. ALL WOOD IN CONTACT WITH CONCRETE SHALL
BE PRESSURE TREATED. RE -TREAT ALL CUT ENDS, NOTCHES, AND DRILLED HOLES IN
ACCORDANCE WITH AWPA M4. MAINTAIN MINIMUM 6" CLEAR BETWEEN WOOD AND EXPOSED
EARTH. MAINTAIN 8" CLEAR BETWEEN EXPOSED EARTH AND NON - TREATED WOOD AT EXTERIOR
FOUNDATION WALLS. ALL NAILS SHALL BE GALVANIZED BOX OR COMMON NAILS. FASTENERS IN
CONTACT WITH PRESERVATIVE - TREATED WOOD SHALL BE OF HOT- DIPPED ZING - COATED
GALVANIZED STEEL OR 5TAINLE56 STEEL IN ACCORDANCE WITH SECTION IBC 2304.9.5. ALL
MINIMUM NAILING SHALL BE PER IBC TABLE 2304.9.1 U.N.O. MACHINE BOLTS TO BE A -301. BOLT
HEADS AND NUTS BEARING AGAINST WOOD SHALL BE PROVIDED WITH STANDARD GUT WASHERS.
MISCELLANEOUS HANGERS TO BE 'SIMPSON' OR ICC APPROVED EQUAL. ALL HANGERS TO BE
FASTENED TO WOOD WITH PROPER NAILS AND ALL HOLES SHALL BE NAILED,
GLUED LAMINATED WOOD MEMBERS:
GLUED LAMINATED WOOD BEAMS (GLB) TO BE IN ACCORDANCE WITH ANSI /AITC STANDARD
AI90.1, AMERICAN NATIONAL STANDARD FOR STRUCTURAL GLUED LAMINATED TIMBER. USE
STRESS GRADE COMBINATION 24F -V4 (Fb = 2,400 PSI) FOR SIMPLE SPANS AND 24F -VS FOR
CANTILEVER AND CONTINUOUS SPANS. SIMPLE SPANS SHALL BE CAMBERED ON A 3500 RADIUS
U.N.O. GLUE SHALL BE CASEIN WITH MOLD INHIBITOR. UNLE55 OTHERWISE SPECIFIED, SEALER
SHALL BE APPLIED TO ENDS OF ALL MEMBERS. BOTTOM LAMINATION TO BE FREE OF UNSOUND
KNOTS LARGER THAN lie" DIAMETER. AITC STAMP AND CERTIFICATION REQUIRED,
PREFABRICATED JOI5T5:
JOISTS SHALL BE AS NOTED ON THE PLANS AND AS MANUFACTURED BY TRU55 J015T
WEYERHAEUSER OR APPROVED EQUIVALENT. JOISTS TO BE ERECTED IN ACCORDANCE WITH THE
PLANS AND THE MANUFACTURER'S DRAWINGS AND INSTALLATION INSTRUCTIONS. CONSTRUCTION
LOADS BEYOND THE DESIGN LOADS ARE NOT PERMITTED. PROVIDE ERECTION BRACING UNTIL
SHEATHING MATERIAL HAS BEEN INSTALLED. PROVIDE SOLID BLOCKING AT CONCENTRATED
LOADS FROM ABOVE AND WEB STIFFENERS PER MANUFACTURER'S DIRECTIONS. JOIST HANGERS
TO BE 51ZED AND PROVIDED BY THE MANUFACTURER OR SUPPLIER
LAMIN TEE) VENEER LUMBER (LVL):
LAMINATED VENEER LUMBER (LVL) TO BE BY TRUSS JOIST WEYERHAEUSER (MIGROLAM) OR
APPROVED EQUIVALENT (Fb = 2,600 PSI, E = 1,900,000 PSI). MATERIAL SHALL BE DESIGNED 8
MANUFACTURED TO THE STANDARDS SET FORTH IN E5R -1381. BEARING LENGTH SHALL NOT BE LESS
THAN 1314" DO NOT CUT OR NOTCH BEAMS WITHOUT PRIOR APPROVAL OR ENGINEER. HEEL CUTS SHALL
NOT OVERHANG INSIDE FACE OF SUPPORTING MEMBER.
BEARING WALL FRAMING:
ALL DOOR AND WINDOW HEADERS NOT CALLED OUT OR OTHERWISE NOTED ON THE PLANS SHALL BE
4x8 DF2 WITH ONE CRIPPLE AND ONE STUD EACH END FOR OPENINGS 5' -0" OR LE55 AND TWO
CRIPPLE25 AND ONE STUD FOR OPENINGS MORE THAN 5' -0" WIDE. ALL COLUMNS NOT CALLED OUT ON
THE PLANS SHALL BE TWO (2) STUDS. SPIKE LAMINATED COLUMNS TOGETHER WITH 16d a 12" O.C.
5TAGGEfRED, STAGGER SPLICES AT TOP PLATES MINIMUM 48" AND NAILS WITH 16d a 8" O.C.
SHEAR WALLS:
ALL SHEAR WALL SHEATHING NAILING AND ANCHORS SHALL BE AS DETAILED ON THE DRAWINGS AND
NOTED IM THE 5HE4R WALL SCHEDULE. USE APA RATED SHEATHING (24/16) WITH A MINIMUM PANEL
EDGE N/41LING OF Sd a 6" O.G. UNLESS NOTED OTHERWISE. ALL SHEAR WALL NAILING SHALL BE
COMMON WIRE OR GALVANIZED BOX NAILS. FASTENERS IN PRESERVATIVE- TREATED WOOD SHALL BE
OF HOT- DIPPED ZINC - COATED GALVANIZED STEEL OR STAINLESS STEEL. BLOCK ALL UNSUPPORTED
PANEL rDGE5. ALL HEADERS SHALL HAVE STRAP CONNECTORS TO THE TOP PLATE AT EACH END
WHEN THE HEADER INTERRUPTS THE TOP PLATE. USE 'SIMPSON' MSTA24 CONNECTOR U.N.O.
FLOOR AND ROOF FRAMING:
DIMENSIONAL FRAMING MEMBERS SHALL BE FREE OF SPLITS, CHECKS, AND SHAKES. PROVIDE DOUBLE
JOISTS UINDER ALL PARALLEL PARTITIONS THAT EXTEND OVER MORE THAN HALF THE LENGTH AND
ALL AROUND ALL OPENINGS IN FLOORS AND ROOFS U.N.O. APPLY 8/4" RATED SHEATHING (40/20)
GLUED 44ND NAILED TO FLOOR FRAMING MEMBERS WITH Sd COMMON OR GALVANIZED BOX NAILS AT
6" O.C. /4T ALL SUPPORTED EDGES AND Sd COMMON OR GALVANIZED BOX NAILS AT 12" O.C. AT
NTERIOiR SUPPORTS, APPLY lie" RATED SHEATHING (24/16) ON ROOF NAILED TO STIFFENERS OR
RAFTER) WITH Sd COMMON OR GALVANIZED BOX NAILS AT 6" O.G. AT SUPPORTED EDGES AND Sd
COMMON OR GALVANIZED BOX NAILS AT 12" O.C. AT INTERIOR SUPPORTS. LAY SHEATHING
PERPENDICULAR TO FRAMING AND STAGGER PANEL EDGES.
ROOF TRUSSES:
TRU55EU TO BE DESIGNED AND SUPPLIED IN ACCORDANCE WITH ANSI /TPI 1 -2002, THE TRU55
CALCULATION PACKAGE SHALL BE PREPARED UNDER THE DIRECT SUPERVISION OF A PROFESSIONAL
ENGINEER LICENSED IN THE STATE OF WASHINGTON. THE TRU55 ENGINEER SHALL ASSUME ALL
RESPONSIBILITY FOR THE WORK OF ALL SUBORDINATES INVOLVED IN THE PREPARATION OF THE
TRU55 FLACEMENT PLAN AND TRU55 DESIGN DRAWINGS. EACH TRUSS SHALL BE PLANT FABRICATED
AND SHALL BEAR THE QUALITY CONTROL STAMP, MANUFACTURER'S NAME, DESIGN LOAD, AND
MAXIMUM SPACING. ALL MECHANICAL CONNECTORS SHALL BE ICC APPROVED AND LOADS SHALL BE
IN ACCORDANCE WITH THE RECOMMENDED ALLOWABLE LOADS. MANUFACTURER SHALL PROVIDE ALL
FRAMING -TO -TRUSS AND TRU55-TO -TRU55 CONNECTION DETAILS AND REQUIRED CONNECTION
MATERI41-5. FABRICATOR SHALL SUBMIT SHOP DRAWINGS TO THE BUILDING DEPARTMENT FOR
APPROVAL PRIOR TO INSTALLATION AND VERIFY ALL TRU55 LENGTHS PRIOR TO FABRICATION.
GENERAL CONSTRUCTION NOTES:
ALL CONSTRUCTION SHALL CONFORM TO THE INTERNATIONAL BUILDING CODE (IBC), 2009 EDITION. THE
CONTRA,GTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND METHODS, TECHNIQUES,
AND SECOUENCES OR PROCEDURES REQUIRED TO PERFORM THE SPECIFIED WORK. THE CONTRACTOR
SHALL VERIFY ALL DIMENSIONS AND ALL CONDITIONS AT THE JOB SITE INCLUDING BUILDING AND SITE
CONDITIONS BEFORE COMMENCING WORK AND BE RESPONSIBLE FOR SAME. THE CONTRACTOR SHALL
PROVIDE TEMPORARY BRACING AS REQUIRED UNTIL ALL PERMANENT CONNECTIONS AND STIFFENERS
HAVE BEEN INSTALLED. THE CONTRACTOR SHALL COORDINATE WITH THE BUILDING DEPARTMENT FOR
ALL BUIILDING DEPARTMENT REQUIRED INSPECTIONS. DO NOT SCALE DRAWINGS. USE ONLY WRITTEN
DIMENSIIONS. THE DETAILS SHOWN ARE TYPICAL AND SHALL BE USED FOR LIKE OR 51MILAR
CONDITIONS NOT SHOWN. VARIATIONS AND MODIFICATIONS TO WORK SHOWN ON THE DRAWINGS SHALL
NOT BE CARRIED OUT WITHOUT THE WRITTEN PERMISSION FROM THE ARCHITECT OR ENGINEER.
3kEAF,
UJALL
SISPEDULE
MARK
MINIMUM
SHEATHING
ANCHOR
REMARKS (4)
SHEATHING (1)
NAILING (1)
BOLTS (3)
2" CDX
Sd a 6" O.C.
1/811 a 60" O.G
Call = 230 PLF
D
OR OSB
/2" CDX
Sd a 4" O.C.
1/811 a 32" O.C.
Call = 350 PLF
OR 05B
h" CDX
ad a 3" O.C.
1/8" a 16" O.G.
Call - 450 PLF
D
OR 05B
USE 3x STUDS AT
ABUTTING PANEL EDGES a
STAGGER NAILS
NOTES
U ALL WALLS DESIGNATED" D" ARE SHEAR WALLS. EXTERIOR WALLS SHALL BE SHEATHED WITH
RATED SHEATHING (24/0, 055 OR CDX) AND NAILED AT ALL PANEL EDGES (BLOCKED) PER
SCHEDULE, NAILING AT INTERMEDIATE FRAMING TO BE AT 12" O.G. NAILING NOT CALLED OUT
SHALL BE PER IBC TABLE 2304.9.1.
2.) HOLDOWN5 AND OTHER FRAMING HARDWARE BY SIMPSON STRONG TIE OR EQUIVALENT TO BE
USED PER PLAN. ENDS OF SHEAR WALLS SHALL USE DOUBLE STUDS MINIMUM.
3) USE MINIMUM OF TWO (2) BOLTS PER SILL PIECE WITH ONE BOLT LOCATED NOT MORE THAN 12"
NOR LE55 THAN 5" FROM EACH END OF EACH PIECE. EMBED BOLTS MINIMUM OF 7 INTO
CONCRETE. WASHERS TO BE 3" x 3" x 14" PER IBC SECTION 2308.12.8 AND OF NOT - DIPPED
ZING - COATED GALVANIZED STEEL,
4) ALLOWABLE LOADS ARE PERMITTED TO BE INCREASED 40% FOR WIND DESIGN IN
ACCORDANCE WITH IBC SECTION 23063.
DEL 2x TOP PLATE
HDR PER PLAN,
II II
II
�I
- - - - -HI
II
II
TRIMMER STUD(5) I I
II II
II II
II II
KING STUD /2" RATED SHEATHING d
NAILING PER SCHEDULE,
I
I
II
LSTA STRAP PER PLAN.
CENTER ON TRIMMER I I
OR KING STUD.
(TYP) I I
2x SILL PLATE I I I I 3x BLOCKING
(TYP)
I
I_F - -
II 1111 II
I LI_ --
I -- ---
SHEAR WALL FORCE TRANSFER DETAIL
51.0 5CALE: NONE
I I
74
UPPER FLOOR'. I,
A = 1,041 SQ FT I J
I
I U
I
S
L
G�6 LSTA30 - HDR e SILL
TO 3x BLOCKING.
(TYR 2 PLACES)
L6TA30 - HDR a SILL
CO =YRIGkT 2012, SEGA ENG NEER5
Z LILI
r
O O
111 — LL
Auiw
U Q
<n p_
V
Z
u,
s,
a
a
m
J
a
0
m
�
pig
Ill
11
i
Ill �I
�I
0
m
m
c
Y
i.
m
� m
� o
L I
C m
ip m
8
ca �
U
m y
w
v
V pJ
ao
m
N
N
LLI
z
I�V
11
I�V
LLI
z
w
Q)
r
CO =YRIGkT 2012, SEGA ENG NEER5
Z LILI
r
O O
111 — LL
Auiw
U Q
<n p_
V
Z
u,
s,
a
a
m
J
a
0
m
�
pig
Ill
11
i
Ill �I
�I
0
m
m
c
Y
i.
m
� m
� o
L I
C m
ip m
8
ca �
U
m y
w
v
V pJ
ao
m
N
N
LLI
z
I�V
11
I�V
LLI
z
w
Q)
2" RATED SHEATHING
ad a 6" O.C. - EXTERIOR SHEATHING PER h" RATED SHEATHING w/ NOTE:
\ \\ PLAN OR SCHEDULE ad a 4" O.C. TO FRAMING TRUSS TO DEVELOP
I
CAPACITY OF CONNECTOR. @ w
ad a 4" O.C.
/a" RATED SHEATHING TRUSS PER PLAN
'SIMPSON' HI FRAMING GABLE END TRU55. SEE r
ANCHOR EACH TRUSS. MANUFACTURER'S DRAWINGS 2x BLOCKING w/ (2) Sd N IY
O
2x BLOCKING w/ 16d a 8' O.C. �
FOR OUTRIGGER LOCATIONS. w w w
TO STUD EACH END
ad a 6" O.C. E USE NI0 -2 AT DB TR U Q N
/2" RATED SHEATHING N Q N
RAFTER OR TRU55 PER PLAN
5IMP50M A35 a 48" O.C. w/ (2) ad TO 2x BLOCKING
2x VENTED BLOCKING. TRUSS PER PLAN DBL 2x TOP PLATE, LAP /-UNLE55 NOTED OTHERWISE. 'SIMPSON' CONNECTOR
END NAIL TO TRUSS a lad a 6" O.C. STAGGERED. BRACING PER TRUSS 2x STUD PER PLAN PER PLAN.
DBL 2x 70P PLATE. LAP SPLICE 4'� O,, MIN. a NAIL w/
. n %
EACH END w/ (2) Sd. SPLICE 4' -0" MIN. a NAIL SUPPLIER NOTE:
SHEATHING AND NAILING PER w/ 16d a 6" O.C. STAGGERED i, SEE ARCH FOR FLASHING 2x STUD (NOT a SIM)
PLAN OR SCHEDULE. SPLICE 2x FRAMING PER PLAN. S�IEATHING a NAILING REQUIREMENTS.
c.
TO OCCUR ON COMMON PEER PLAN OR SHEAR = DEL 2x TOP PLATE.
(BEAM AT SIM)
MEMBER OR BLOCKING WALL SCHEDULE.E (BEAM AT SIM.)
44
c
TYPICAL ROOF FRAMING CONNECTION z ROOF FRAMING GABLE END LOWER ROOF FRAMING a SHEAR WALL (4 DRAG STRUT CONNECTION
S2.m SCALE: I" = I' -m" 52.m SCALE: I" = I' -m" 52.m SCALE: I" = I' -m" S2.m SCALE: I" = I' -m"
FF' m m o
akJ U a
c �
�✓ � E m
50LE PLATE NAILING. v o w
USE 16d a I6" O.G. MIN. 16d a S" O.C. SOLE .
SIMP5ON' HOLDOWN PLATE NAILING. =°
STRAP PER PLAN SOLID RIM JOIST ad a 4 OC SHEATHING a NAILING
6d a S" O.C. SOLE m o
PLATE NAILING, y
t2x " SUBFLOOR 3 /4" 5U5FLOOR SCHEDULE O.C. UNO SHEATHING a NAILING
3) ad J015T -TO -TOP TJI BLOCKING 4 PER PLAN OR 8d a 6" O.G. UNO
m
PER OR Sda6
SHEATHING a NAILING PER PLAN. LATE U.N.O. MAINTAIN f JOIST PER PLAN SUBFLOOR SCHEDULE
IN. II /2" END DISTANCE. and a 4" O.C. STAGGER SIDES. M5TC HOLDOWN �3ja" SUBFLOOR
SPLICE TO OCCUR ON COMMMON NAIL THROUGH TOP SURFACE PER PLAN
m
MEMBER OR BLOCKING LU626 HANGER \ ,
DO NOT TOE -NAIL)
� I
SHEATHING a NAILING PER
TRUSS OR RAFTER
2x STUDS PER PLAN. PLAN OR SCHEDULE. n
J015T PER PLAN
(BEAM AT 51M.) JOIST PER PLAN (NOT Al SIMJ
y,
L TOP PLATE . LAP �J015T PER PLAN 2x FRAMING PER PLAN. BEAM PER PLAN CE 4' -0" MIN. a NAIL ti US HANGER
w/ 16d a 6" O.C. STAGGERED. (BEAM AT 51MJ
BEAM PER PLAN
s TYPICAL FLOOR FRAMING CONNECTION FRAMING AT INTERIOR SHEAR WALL SHEAR WALL FRAMING AT FLUSH BEAM SHEAR WALL FRAMING AT FLUSH BEAM
52.0 SCALE: I" = I' -m" S2.m SCALE: I" : 1' -0" S2.m SCALE: I"= I' -m" 52.m SCALE: I": I' -m"
3/4" 5UEFLOOR 16d a 16" O.C. SOLE
2x STUD PER PLAN. USE MINIMUM PLATE NAILING. 16d a 16" O.C. SOLE
2x BLOCKING (2) 2x STUD a ENDS OF SHEAR
WALLS a HOLDOWN5. SEE SHEAR 3j4" SHEATHING PLATE NAILING.
JOIST PER PLAN 3/
6d a S" O.C. SOLE WALL SCHEDULE FOR 3x STUDS. 4' SUBFLOOR
SHEATHING a NAILING s ALIGN SIM SO ?NMEMBEDDED SOTHD (�/4L�m PLATE2
PER PLAN OR PLATE NAILING. SIMIPSON' SHEATHING a NAILING M_ JOIST -TO -TOP
ANCHOR BO w/ 3 x3' x 4 ER.
2x BLOCKING w/ AC CAP USE eGm ArTU60 FOR
CC. SPACING. UN.O. MAINTAIN
SGNEDULEE Sd a 6' O.C. UNO \ PER PLAN. IN. 1'/2" END DISTANCE.
ALT. Ix4 GUSSET EA 2x PT SILL TYPE HOLDOWN BELOW.
I6d a 8 O.C. 4' SUBFLOOR SIDE w/ (6) ad )
I/2" RATED SHEATHING
MIN. " BAR - HORIZ.
4x6 A7 SPLICE) �' i SHEATHING a NAILING PER PLAN.
4 'SIMPSON' NOLDOWN PER PLAN.
SIMFb5ON' MAB ANCHOR "41 SPLICE TOEMBER OR BLOCKING STUD a 16
(ALT. A34 ANCHOR MIN BAR a 24" O.G. -VERT. STUD a ENDS OF
USE
MSTG HOEDOWN JOIST PER PLAN TWO SIDES) 12" ' -6" MIN R WALLS a HOLD OUNS.
PER PLAN 8" F ?G PER PLAN MIN. 2' -6" MAX. 14 BAR CONTINUOUS 101-011
IU5 HANGER
LU524 HANGER BY D o 8° L MAX. z
TRUSS SUPPLIER BEAM PER PLAN
FIN15L4 GRADE o 0 2x NAILER AND PT SILL wl Si "D
SHEATHING a NAILING e fu
E1,a 1, PER PLAN. MATCH WALL ANCHOR BOLT a 3" x 3" x 1/4"
ABOVE U.N.O. 1- WASHER AT 5' -0" O.C. U.N.O. n 9 ll
z.m SCALE: 1" , FRAMING AT CRAWL SPACE FOUNDATION AT GRAWL SPACE U J —A
g SHEAR WALL FRAMING AT FLUSH BEAM EIS FLOOR
sz.m SCALE: I" : ' -m" ' -m^ 52.m SCALE: w = ' -0" 5THD TYPE HOLDOWN y
PER PLAN.
04 BAR a 10" O.C. - HORIZ.
SHEATHING a NAILING PER 2x STUD PER PLAN. USE DEL STEM WALL " a 16" O.C. MUM
VERT. MA 01
FIN15H GRADE
4LBAR ) < ~
L - XI
PLAN OR SCHEDULE STUD AT END OF SHEAR WALLS
a HOEDOWNS. SEE SHEAR WALL FINISH GRADE Z
2x PT SILL w/ ANCHOR BOLT SCHEDULE FOR 3x STUDS. �___________—
a 3" x 3" x 1/4 WASHER PER ° a
PLAN OR SCHEDULE. USE 4" SLAB ON GRADE OVER ( IS" MIN
5g° " O.C. MIN. _ MIN. 6 MIL VAPOR BARRIER 2'_0" a a a
14 BAR CONTINUOUS MINIMUM IS"
/ roa60 O
6" MIN. I� a� n (TYPJ
FINISH GRADE OR TN8s8�
2" MAX. all ""
SLAB ON GRADE
SIMP50N' HOLDOILN 4 BAR a 2�RO.C. - VERTICAL -- — ? — At UI 2
PER PLAN _
F-6" MIN _ 8 MAX. MAx z CRIPPLE WALL WITIH BACKFILL FOUNDATION
SCALE: NONE �'
8' I
�. t
il
CONTINUOUS FTG. -0
MINIMUM '
'�8 04 BAR CONT. REINFORCEMENT l � 2, �y
Qa3 FOUNDATION AT SLAB ON GRADE
STEPPED FOOTING DETAIL
62.m SCALE: I" = F -O" 1S2.m SCALE: NONE COPYRIGH— 2012, 5EGA ENGINEERS