20140164 MECH-SUM2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 2012 Washinqton State Enerqy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 R2 and R3 Revised June 2013 Project Info Project Address Olympia Federal Savings Yelm Date 6/3/2013 Corner of Yelm Ave. & Tahoma Blvd. For Building Dept. Use Applicant Name: Sunset Air, Inc. Applicant Address: 5210 Lacey BLVD SE, Lacey WA 98503 Applicant Phone: 360 - 456 -4956 Project Description Briefly describe mechanical system type and features. Includes Plans New geothermal heatpump system including 5 indoor heat pumps, 1 ground loop, 1 exhaust and outdoor air heat exchanger, 1 exhaust fan. Drawings must contain notes requiring compliance with commissioning provisions per Section C408 Compliance Option • Simple System Complex System Systems Analysis Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Coolin g Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' Capacity2 Btu /h OSA CFM or Econo? SEER or EER IPLV3 Econmizer Option or Exception 6 Heat Recovery Y/N See M1.0 Heatin g Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' Capacity2 Btu /h OSA cfm or Econo? Input Btuh Output Btuh Efficiency4 Heat Recovery Y/N See M1.0 Fan Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' CFM SP' HP /BHP Flow Controls Location of Service Service Water Heating Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' Input Capacity Sub - Category EF7 Location of Service See M1.0 1 If available. 2 As tested according to Table C403.2.3(1)A thru C403.2.3(8). 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume (VAV), constant volume (CV), or variable speed (VS). 6 Economizer exception number per Project Address Olympia Federal Savings Yelm Date 6/3/2013 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH -CHK pages. Applicability Code Section Code Provision Information Required Location on Building Department (yes,no,na) Plans Notes GENERAL PROVISIONS Equipment Sizing & Performance Yes C403.2.1 Load calculations Load calculations performed per ASHRAE Std 183 or equivalent per M 1.0 Chapter 3 Yes C403.2.2 Equipment and system Output capacity of heating and cooling equipment and systems do not M1.0 sizing exceed calculated loads note exceptions taken Yes C403.2.5 Minimum ventilation Ventilation (natural or mechanical) provided per IMC, indicate mechanical M 1.0 ventilation is capable of being reduced to minimum requirement per IMC C4032.3 & minimum Provide equipment schedules or complete MECH -SUM tables with type, Yes 0403.2.3.2 &Equipment efficiency capacity, efficiency, test standard (or other efficiency source) for all M 1.0 C4032.12.1 mechanical equipment Yes 0403.2.13 Electric motor efficiency Provide equipment schedule with hp, rpm, efficiency for all motors, note M1.0 except- Yes C403.2.10 Fan power limitation Fan system motor hp or bhp does not exceed limits per Table M 1.0 C403.2.10.1 1 Yes 04032. 10.3 Fractional h fan motors p Indicate fan motors 1/12 to 1 hp are ECM type or meet minimum efficiency M 1.0 & C403.2.13 re q. N/A 0403.2.3 Maximum air cooled chiller Indicate air - cooled chiller capacity does not exceed air - cooled chiller limit ca acit N/A 0403.2.1 Non - standard water - cooled Full -load and NPLV values for water - cooled centrifugal chiller adjusted for chillers non - standard operational conditions N/A 0403.2.12.1 _ Centrifugal fan cooling Large capacity cooling towers with centrifugal fan(s) meet efficiency towers requirements for axial fan open circuit cooling towers N/A C403.2.3 Forted air furnace and unit Indicate intermittent ignition or 1113, flue /draft damper & jacket loss Yes C403.2.3.3 Packaged electric List equipment required to be heat pumps on schedule M 1.0 heatin /coolin a ui ment N/A C403.2.3.4 Humidification Indicate method of humidification (note requirements for systems with economizer HVAC System Controls & Criteria Yes C403.2.4.1 Thermostatic controls Indicate locations of thermostatic control zones on plans, including M 1.0 perimeter s stems C4032.4.1.1 Heat pump supplementary Indicate staged heating (compression /supplemental) & outdoor lockout Yes heat temp M 1.0 Yes C403.2.4.2 Setpoint overlap (deadband) Indicate 5 °F deadband minimum for systems controlling both heating & M 1.0 cooling Yes C403.2.4.3 Automatic setback and Indicate zone t -stat controls with required automatic setback & manual M 1.0 shutdown override Yes C4032.4.3.3 Automatic (optimum) start Indicate system controls that adjust equip start time to match load M 1.0 conditions 0402.4.5.2 & Dampers Indicate location of OSA, exhaust, relief and return air dampers, include M 1.0 Yes C403.2.4.4 AMCA rated leakage and control a motorized or ravi note N/A C403.2.11 Heating outside a building Indicate radiant heat system and occupancy controls N/A C403.2.4.5 Snow melt systems Indicate shut -off controls based on outdoor conditions N/A C403.2.4.6 Combustion heating Indicate modulating or staged control equipment N/A C403.2.4.7 Group R1 hotel /motel Indicate method for guest room automatic setback & set -up of 5 °F minimum s stems N/A C403.2.4.8 / E Group R2/R3 dwelling unit Indicate 5 -2 programmable thermostats in primary spaces with minimum of systems two setback periods; note exceptions taken N/A C403.2.5.1 Demand controlled Indicate high- occupancy spaces and systems requiring DCV ventilation N/A C403.2.5.2 Occupancy sensors Indicate spaces requiring occupancy -based system control and method, or alternate means provided to automatically reduce OSA when partially C403.2.5.3 Enclosed loading dock/parking garage Indicate enclosed loading dock and enclosed parking garage ventilation N / A ventilation system activation and control method N/A C4032.5.4.1 Kitchen exhaust hoods Indicate kitchen hoods requiring make -up air; indicate make -up air source and conditioning method Indicate lab exhaust systems requiring heat recovery, method & efficiency, N/A C4032.5.4.2 Laboratory exhaust systems or alternative method taken (VAV, semi - conditioned makeup, or CERM calculation C403.2.6.1 Energy recovery - Indicate ventilation systems requiring ER, method & efficiency, note Yes ventilation systems exceptions M 1.0 N/A C403.2.6.2 Energy recovery - condensates stems Indicate on -site steam heating systems requiring energy recovery N/A C403.2.6.3 Energy recovery - Indicate remote refrig. condensers requiring ER and use of captured energy condensers stems Mechanical Permit Plans Checklist - Page 2 of 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Address Olympia Federal Savings Yelm Date 6/3/2013 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH -CHK pages. Applicability Code Section Code Provision Information Required Location on Building Department (yes,no,na) Plans Notes GENERAL PROVISIONS, CONTINUED HVAC System Controls & Criteria, Continued Yes 0:403.2.12 Variable flow control - Indicate fan & pump motors requiring VF control & method (VSD or equiv M 1.0 fans/ um Ds controls N/A C4032.12.1 Variable flow control - Indicate cooling tower fans requiring variable flow control and method cooling towers N/A 04032.12.2 Large volume fan systems Indicate fan systems requiring airflow reduction based on heating and cooling demand; or exception taken C4032.12.2 Single zone AC systems Indicate method of cooling demand -based fan control for sys. > 110,000 N/A btuh Yes C4032.4.10 DDC system capabilities Identify all DDC system input/output control points and indicate capability M 1.0 for trendina and demand response set point ad ustment Ducting Systems Yes 0403.2.7.1 & Duct construction Indicate all ductwork constructed and sealed per IMC, C402 leakage M 1.0 C403.2.7.3 requirements and IBC vapor retarder requirements Yes 403.2.7.3.1- Duct pressure classifications Identify location of low, medium and high pressure ductwork on plans M 1.0 C4032.7.3.3 High pressure duct leakage Indicate high pressure duct leakage testing requirements on plans; provide Yes test test results to jurisdiction when completed M 1.0 Yes 0:403.2.7.1 / Duct insulation Indicate R -value of insulation on ductwork M 1.0 Piping Systems Yes C403.2.8 Piping insulation Indicate R -value of insulation on piping M 1.0 N/A C403.2.8.1 Piping insulation exposed to Indicate method of protection from damage /degredation weather SIMPLE SYSTEMS Qualifying Systems Yes 0403.3 Qualifying single zone Verify unitary or packaged equipment does not exceed capacity limits, does M1.0 systems not have active humidifcation or simultaneous heating/cooling N/A 0403.3 Qualifying 2 -pipe heating Verify 2 -pipe heating -only system does not exceed capacity limits s stems Yes C403.3.2 Hydronic system controls Refer to Complex Systems Section C403.4.3 M 1.0 Simple System Economizers N/A C403.3.1 Air economizer required Indicate cooling systems requiring economizer controls, note in equip sched. N/A C403.3.1.1.1 Air economizer capacity Indicate modulating OSA control capability up to 100% OSA, or exception N/A C403.3.1.1.3 Air economizer high limit Indicate high limit shut -off control method per Table C403.3.1.1.3(2) controls N/A C403.1.12 Integrated air economizer Indicate capability for partial air economizer operation for systems with o eration Icapacity > 65,000 btuh N/A C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with exce tion s COMPLEX SYSTEMS Complex System Economizers C403.4.1 Air economizer required Indicate cooling systems requiring economizer controls, note in equip N/A sched. C403.4.1.4 Economizer heating system Verify control method of HVAC systems with economizers does not N/A impact increase building heating energy usage during normal operation N/A C403.4.1.3 Integrated economizer Indicate capability for partial economizer operation for air or water econo operation systems Moved Water economizer capacity Indicate water econo capable of 100% cooling capacity at 50 °F db /45 °F wb N/A OSA C403.4.1.2 Water economizer Indicate precooling coils and heat exchangers do not exceed pressure drop N/A maximum pressure drop limit N/A C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with exce tion s Mechanical Permit Plans Checklist - Page 3 of 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Address Olympia Federal Savings Yelm Date 6/3/2013 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH -CHK pages. Applicability Code Section Code Provision Information Required Location on Building Department (yes,no,na) Plans Notes COMPLEX SYSTEMS, CONTINUED Specific System Requirements N/AC403.4.2 / & C403.2.12 Variable flow control - fans Indicate fans requiring variable flow control and method N/A C403.4.2.1 VAV fan static pressure Indicate sensor locations on plans, include at least one sensor per major sensors duct branch C403.4.22 VAV fan static pressure Indicate fan system static pressure setpoint based on zone requiring most N/A setpoint pressure VAV systems serving multi- Indicate supply air systems serving multiple zones that are required to be C403.4.5 VAV, method of primary air control, and zones served, note exceptions N/A zones taken N/A C403.4.5.4 VAV system supply air reset Indicate controls that automatically reset supply air temp in response to loads N/A C403.4 Large capacity cooling Indicate method of multi -stage or variable control for building cooling s stems system capacity > 300 tons N/A C403.4.7 Hot gas bypass limitation Indicate cooling equipment unloading or capacity modulation method N/A C403.4.3 Large capacity boiler Indicate multi -stage or modulating burner for single boilers > 500,000 btuh systems N/A C403.4.3 Boiler sequencing Indicate automatic controls that sequence operation of multiple boilers N/A C403.4.3.5 Chiller / boiler plant pump Indicate capability to automatically reduce overall plant flow and shut -off isolation flow through chillers & boilers when not in use N/A C403.4.2 & Variable flow control - Indicate pumps requiring variable flow control & method C403.4.3.6 pumps N/A C4032.12.1 Variable flow control - Indicate cooling tower fans requiring variable flow control and method & C403.4.4 cooling towers N/A C403.4.34 . Hydronic system part load automatically reset supply water temp AND reduce flow by ? 50% for controls N/A C403.4.32 Two -pipe changeover Indicate deadband, heating /cooling mode scheduling and changeover systems temperature range N/A C403.4.3.3.1 Water loop heat pump - Indicate capability of central equipment to provide min. 20 °F water supply deadband temp, deadband between heat re ection and heat addition modes N /A C403.4.3.3 Water loop heat pump - Provide heat exchanger that separates cooling tower and heat pump loop in heat re ection Climate Zone 5 N/A C403.4.3.3.3 Water loop heat pump - Indicate 2 -way isolation valve on each heat pump and variable flow control isolation fors stems with total pump power > 10 h N/A C403.4.6 Condenser water heat Indicate system provided to pre -heat service water and efficiency recovery N /A C403.5 Cooler / freezer - anti -sweat Indicate w /sf & control method for walk -in cooler /freezer door anti -sweat heaters heaters N/A C403.5 / 6 Cooler / freezer - evaporator land Indicate motor type for evaporator and condenser fans < 1 hp SERVICE WATER HEATING Service Water Systems YES C404.2 Water- heating equip min. Provide equipment schedule or complete MECH -SUM table with type, P -1 efficiency capacity, efficiency, test standard or other efficiency source YES C404.3 Temperature controls Indicate temperature controls have required setpoint capability P -1 N/A C404.4 Heat traps Indicate piping connected to equipment have heat traps on supply & discharge YES C404.5 Insulation underwater Indicate R -10 insulation under tank P -1 heater YES C404.6 Service water piping Indicate R -value of insulation on piping, note exceptions taken P -1 insulation C404.7 / g Circulation systems and Indicate shut -off capability based on occupancy and periods of limited YES heat trace shut -off demand P -1 N/A C404.9 Group R -2 service hot water Indicate method of usage metering for dwell. units served by central HW meters System Pools & In- Ground Permanently Installed Spas Pool heating equip min. Provide equipment schedule or complete MECH -SUM table with type, N/A C404.10.1 efficiency capacity, efficiency, test standard (or other eff. source), heat pump heaters 4 COP N/A C404.10.1 / 2 Pool heater on / off controls Indicate automatic on /off control based on scheduling & accessible on /off switch on heater that operates independent of thermostat setting, or N/A C404.10.3 Pool covers Indicate vapor retardant cover and insulation rating as required N/A C404.10.3 Pool assembly insulation Indicate rating of insulation on sides and bottom of pools heated to > 90 °F I N/A C404.10.4 Heat recovery Indicate method, exhaust air temperature reduction and recovered energy use