20140164 Energy Summary 080520142012 Washinaton State Enerav Code Compliance Forms for Commercial Buildings includinq R2 & R3 over 3 stories and all R1
Revised Oct 2013
Commercial Provision Chapters 1 - 5 of the 2012 Washington State Energy Code apply to all commercial
occupancies, R -2 and R -3 occupancies greater than 3 stories above grade, and R -1 occupancy (all building heights).
Intro
This file, ENV12- v3.XLSM, has electronic compliance forms for envelope provisions as defined in Sections C101,
C303, C402 and Appendix A for Climate Zones 4c and 5b. There are two companion files: LTG12- v3.XLSM (Section
C405 lighting, motor, and transformer requirements), and MECH12- v3.XLSM (Section C403 mechanical systems
requirements).
This form is a compliance aid and is not a substitute for the full energy code text or specific jurisdiction compliance
Energy Code
requirements. Users should refer to the code text and contact the local jurisdiction for complete information. The full 2012
WSEC code text is available for download from the NEEC website:
htto: /www. neec. neVeneray -codes
Training
Refer to the NEEC website for instruction on how to complete all of the 2012 WSEC Compliance Forms.
Start -up
Select this file from the NEEC website to download to your computer. When opening the file be sure to Enable Macros.
This file is an Excel workbook that contains multiple compliance forms and resources in Excel worksheets. Each
Overview
worksheet is indicated by a tab at the bottom of the screen. You may visit each worksheet by selecting it's tab.
Most calculations are automated. Cells that display informational text and the results of calculations are write -
protected and cannot be edited.
Save Files
This file is saved in the same manner as any standard Excel file.
Getting
Some forms have two pages. Both pages are available on screen when you select the tab for a form (worksheet). Use
Around
the scroll bars to find the second page located below the first page.
All general project information and the date are entered once on ENV -SUM. This information is automatically
replicated on all other ENV forms. The ENV -SUM form accompanies all other ENV forms.
Only input cells are accessible. If you try to edit a write- protected cell an error message will appear requesting a
password. A password IS NOT required to complete these forms. You may use the TAB key to move to the next input
cell. If the TAB doesn't take you where you want to go, use your mouse to move around the form.
Avoid excessively long text strings when entering information. In some cases, text that extends beyond the available
Input Cells
space will not be visible. In most cases the text will wrap within the cell. This may force part of the form onto a new page.
To enter the date, use this format: mm /dd /yyyy. For example, you would enter 7/1/2013 or 12/21/2014.
Check boxes can be checked or unchecked by clicking in the box with your mouse. Radio buttons (circles) allow only
one in a set to be selected.
Drop -down lists have an arrow at the right side of the cell. Click on the arrow with your mouse and select the
appropriate option. Use the delete button on your computer to clear a drop -down entry.
When a form has a space for notes or explanation, click anywhere in the space to edit.
Personalizing
You can personalize the forms with your company name, address, phone, or any other information. This is done by
editing the header or footer in Excel.
Many tables, such as for listing envelope assembly types, have a certain number of lines available for entering data.
Adding Lines
You may need more lines to enter all your information. Where this feature is available, you can add additional lines to the
and
table by selecting the 'Y' button on the right hand side of the table with your mouse. If you can't see the 'Y' button, scroll
to the right or increase the View Zoom setting for the worksheet.
Removing
To remove lines that you have added, select the "" button with your mouse. You cannot remove lines that were not
added; an error message will appear if you try.
If you add additional lines with this method, the pagination may be affected forcing the forms to carry additional lines
over to other pages. Be sure to submit all pages to the plans examiner.
Compliance
You must select a Compliance Path on ENV -SUM (line 12) to activate the correct input method for Window -to -Wall
Path
and Skylight -to -Roof ratios.
Occupancy
You must select an Occupancy Group on ENV -SUM (line 14) for this workbook to display the correct code
,Group
requirements and automatically calculate component performance target UA values.
2012 Washinaton State Enerav Code Compliance Forms for Commercial Buildinas includina R2 & R3 over 3 stories and all R1
Revised Oct 2013
For projects complying via the Prescriptive Path, enter the vertical fenestration area, gross wall area (includes vertical
fenestration, doors, etc), skylight area and gross roof area (includes skylights, mechanical equipment curbs, etc) directly
Fenestration
into the Vertical Fenestration and Skylight Area Calculation input cells on the ENV -SUM form. The form will calculate
Area
the Window -to -Wall and Skylight -to -Roof ratios.
For projects complying via the Component Performance Path, the Vertical Fenestration and Skylight Area inputs in
the ENV -SUM form are write protected. Enter all applicable envelope information in the ENV -UA form. The resulting
Window -to -Wall and Skylight-to-Roof ratios will auto fill into the ENV -SUM form from the ENV -UA form.
The prescriptive vertical fenestration target area is 30 %. This target increases to 40% if the project complies with the
Vertical
requirements of either C402.3.1.1 50% floor area within the daylight zone, or C402.3.1.3 high performance vertical
Fenestration
fenestration.
Alternates
If the project is eligible for one of these alternates, select the corresponding button on Line 24 of the ENV -SUM form.
This will re- calculate the prescriptive target area in the ENV -SUM and ENV -UA forms based on 40 %.
Target Area Adjustment is required if the project exceeds the prescriptive target area for vertical fenestration or
Target Area
skylights. Adjusted target areas are automatically calculated in the ENV -UA form using envelope assembly areas you
Adjustment
enter for your project. Adjusted target areas will appear in the Target UA column in the ENV -UA form. Refer to Target
Area Ad ustment worksheet for the supporting calculations.
The forms should print on any printer supported by your operating system. You will need to have the following
TrueType fonts installed under Windows: Arial, Times New Roman, Courier New and Wingdings. These are all standard
Windows fonts.
If you are losing form details when printing, you may have a shortage of printer memory. Try printing problem pages
individually.
Printing
By default, only the active worksheet is printed. To print more than one worksheet at a time, open your print set -up
menu and select either the page range you wish to print or Entire Workbook.
Forms (worksheets) in a workbook may not be deleted because the file is locked.
To print blank forms to fill out by hand, delete all of the heading information at the beginning of ENV -SUM and select
Blank Forms
the desired Occupancy Group.
For each radio button group there is a button labeled "Clear." Clicking this button will clear the other buttons so that
they will print as empty circles. The "Clear' button will not print.
End of Instructions for Electronic Forms
2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Oct 2013
Project Info
Project Address Olympia Federal savings Yelm
Date 8/4/2014
Compliance forms
Corner of Yelm Ave. & xanoma Blvd.
For Building Department Use
do not require a
password to use.
Instructional and
Applicant Name: Sunset Air, Inc.
calculating cells are
write - protected.
Applicant Address: 5210 Lacey BLVD SE, Lacey WA 98503
Applicant Phone: 360 -456 -4956
Project Description
21 New Building ❑ Addition ❑ Alteration ❑ Change of Occupancy /Conditioning
Compliance Path
O Prescriptive O Component Performance O Total Building Performance
Selection required to enable forms.
Occupancy Group
OO Commercial O Group R - R2 & R3 over 3 stories and all R1
Selection required to enable forms.
Vertical Fenestration and
Total Vertical Gross Exterior
Skylight Area Calculation
Fenestration Above Grade % Vertical
If complying via the Prescriptive path,
(rough opening) divided by Wall Area times 100 equals Fenestration
1486.0 — 9143.0 X 100 - 16.3 $
enter values for vertical fenestration,
skylights, gross walls and roof on this
ENV -SUM worksheet. Ifcomplying via
the Component Performance path, enter
Gross Exterior
these values in the ENV -UA worksheet.
Total Skylight divided by Roof Area times 100 equals % Skylight
These values auto-fill from ENV -UA and
are write - protected on ENV -SUM.
0.0 _ 6315.0 X 100 = 0.0%
Fenestration Area
Vertical VERTICAL FENESTRATION AREA COMPLIES
Fenestration Area
Compliance
Skylight Area SKYLIGHT AREA COMPLIES
Vertical Fenestration
O 50% or more of the floor area is within a daylight zone per C402.3.1.1
Alternates
O High Performance Fenestration U- factors and SHGC per C402.3.1.3
Compliance Method
❑ Skylight area 3% or greater, VT -0.40 or greater
Single Story Spaces
❑ Skylight effective aperture 1% or greater, provide calculation
Requiring Skylights
❑ Space eligible for exception
Requires a minimum of 50% of floor area to be within a skylight daylight zone for specific
space types. Refer to C402.3.2 for requirements.
❑ Project has semi - heated spaces as defined per C402.1.4
❑ Applying wall exception to semi - heated spaces
1. Semi - heated spaces may comply under Prescriptive or Component Performance compliance
Semi - Heated Spaces
path.
2. Semi - heated spaces shall be documented separately from other conditioned spaces– provide
separate compliance forms for each conditioned space type.
3. Envelope elements separating semi - heated from other conditioned spaces shall comply with
exterior thermal envelope requirements.
[I Walk -in Cooler ❑ Walk -in Freezer
El Refrigerated Warehouse Cooler E] Refrigerated Warehouse Freezer
Refrigerated Spaces
Refrigerated spaces shall comply under the Prescriptive Path only. Compliance documentation for
these areas maybe combined with non - refrigerated areas in the ENV - PRESCRIPTIVE form. Refer
to C402.5 and C402.6 for requirements.
Project includes more than one occupancy type and /or level of space conditioning. Multiple
Mixed Occupancy and/or
compliance forms maybe required. Select all that apply to scope of project:
Space Conditioning
El Commercial ❑ R2 & R3 over 3 stories and all R1 ❑ Refrigerated Space
❑ Fully Conditioned ❑ Semi - Heated ❑ Low Energy*
❑ R2 & R3 - 3 stories or less
*Low energy areas are exempt from all thermal envelope provisions and compliance forms for
these areas are not required. Refer to C101.5.2 for exemption.
2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R Revised Oct 2013
Minimum Req uirements This table summarizes prescriptive compliance requirements for opaque elements and fenestration. Refer
for Prescriptive Compliance to Tables C402.1.2, C402.2 and C402.3 in the 2012 WSEC for important footnotes that apply to
these tables. Refer to Section C402 for all applicable requirements that apply for each envelope element
type and applicable exceptions.
Prescriptive Path
Table C402.2 Notes 1,7
Insulation Minimum R -Value
Table C402.1.2 Notes 1,2
Assembly Maximum U- factor
Occupancy Group
All Other Group R
All Other Group R
Opaque Elements
Roofs
Insulation Entirely above Deck
R -30 c.i.
R -38 6.
U -0.034
U -0.031
Metal Building with R -3.5 thermal blocks) Note 3
R -25 + R -I 1 Ls
R -25 + R -11 Ls
U4031
U -0.031
Attic and Other
R -49
R49
U -0.021
U -0.021
Walls, Above -grade
Mass
R -9.5 c.i.
R -13.3 c.i.
U -0.104 Note 6
U -0.078
Metal Building
R -13 + R -13 c.i.
R -13 + R -13 c.i.
U -0.052
U -0.052
Steel Framed
R -13 + R- 10c.i.
R -19 + R -8.5 c.i.
U -0.055
U -0.055
Wood Framed and Other
R -21 int
R -21 int
U -0.054
U -0.054
Below Grade Wall Note 4
Same as above grade
Same as above grade
Floors
Mass
R -30 c.i.
R -30 c.i.
U -0.031
U -0.031
Steel Joist
R -38 + R -10 c.i.
R -38 + R -10 c. i.
U -0.029
U -0.029
Wood Framed and Other
R -30
R -30
U -0.029
U -0.029
Slab -On -Grade Floors
Unheated
R -10 for 24 in. (from top of slab)
F -0.54
F -0.54
Heated Note 5
R -10 perimeter & under entire slab
F -0.55
F -0.55
Opaque Doors
Swinging
No R -Value for prescriptive compliance.
U -0.37 U -0.37
Roll-up or sliding
R-4.75 I R -4.75
No U -Value for prescriptive compliance.
Table C402.3 - 0-30% of wall area, or
30%-40110 per Section C402.3.1.1 DLZ
Section C402.3. L3 High Performance
Fenestration Option - 040% of wall area
Fenestration
Assembly Maximum U- factor Notes 1,2
Vertical Fenestration
Nonmetal framing
U -0.30
U -0.30
U -0.28
U -0.28
Metal framing (fixed)
U -0.38
U -0.38
U -0.34
U -0.34
Metal framing (operable)
U -0.40
U -0.40
U -036
U -0.36
Entrance doors
U -0.60
U -0.60
U -0.60
U -0.60
Skylights
Skylights
U -0.50 U -0.50 U -0.50 U -0.50
Fenestration
Assembly Maximum SHGC Factor
Vertical Fenestration
PF < 0.2: all orientations - SHGC -0.40
0.2 <_ PF < 0.5: north - SHGC -0.44;
all other - SHGC -0.48
PF ? 0.5: north - SHGC -0.48;
all other - SHGC -0.64
PF < 0.2: all orientations - SHGC -0.35
0.2 <_ PF < 0.5: north - SHGC - 0385;
all other - SHGC -0.42
PF ? 0.5: north - SHGC -0.42;
all other - SHGC -0.56
Skylights
SHGC -0.35
SHGC -0.35
Refrigerated Spaces Insulation
Insulation Minimum R -Value
Table C402.5 and C402.6
Assembly Maximum U- factor
Freezers - Walk -in and Warehouse
Roof/ Ceiling
R -32
No U -Value for prescriptive compliance
Wall
R -32
Door
R -32
Door - transparent reach -in
triple -pane, heat - reflective treated or gas
Floor
R -28
Coolers - Walk -in and Warehouse
Roof/ Ceiling
R -25
No U -Value for prescriptive compliance
Wall
R -25
Door
R -25
Door - transparent reach -in
double -pane, heat - reflective treated & gas
fill, or comply with freezer door req.
Floor
No Requirement
2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R rceviseo
Definitions:
Ls = Liner system -- A continuous membrane installed below the purlins and uninterrupted by framing members. Uncompressed, unlaced
insulation rests on top of the membrane between the purlins. Refer to Section A 1012.5.4.
e.i. = Continuous insulation -- Insulation that is continuous across all structural members without thermal bridges other than service
openings and penetrations by metal fasteners with a x- sectional area of less than 0.04% of the opaque surface area of the assembly.
int = Intermediate framing -- Includes insulated headers, comers and interior partition wall to exterior wall intersections. Refer to Section
A103.2 for framing definitions.
Footnote Summary:
Each table in the 2012 WSEC has footnotes applicable to specific information provided in the table. This footnote summary provides only
abbreviated details from these footnotes. Refer to 2012 WSECfor completefootnote information.
1 - Assembly descriptions can be found in Chapter 2 and Appendix A.
2 - Use of assembly U- factors, C- factors and F- factors from Appendix A and Chapter 3 are required unless otherwise allowed by the
provisions of this Code.
3 - For metal building roofs where using R -value compliance method, a thermal spacer block is required. Otherwise use the U- factor
compliance method.
4 - Where heated slabs are below - grade, below -grade walls shall comply with the exterior insulation requirements for heated slabs.
5 - Heated slab F- factors shall be determined specifically for heated slabs. Unheated slab F- factors shall not be used.
6 - Non - residential CMU walls may be eligible to use Table C402.1.2 U- factor if all provisions stated in applicable footnote are met. Refer to
Footnote D in Table C402.1.2 or Footnote C in Table C402.2 for eligibility requirements.
7 - Roof, wall or Floor assemblies required to have continuous insulation may be eligible for alternate continuous insulation R- values if all
provisions in applicable footnote are met. Refer to Footnote F in Table C402.2 for eligibility requirements.
End of Envelope Requirements Summary
2012 Washinaton State Enerav Code Compliance Forms for Commercial Buildings includinq R2 & R3 over 3 stories and all R1 Revised Oct 2013
Project Address of
J Olympia Federal Savings Yelm
Date 08/04/2014
Occupancy Group OO Commercial O Group R
For Building Department Use
Change in occupancy or space conditioning O
Note - Proposed UA may exceed Target UA by 10% per C101.4.4 and C101.4.5
Fenestration Area as % gross above -grade wall area 16.3% Max. Target: 30.0%
Skylight Area as % gross roof area 0.0% Max. Target: 5.0%
Vertical Fenestration Alternates: None Selected on ENV -SUM
Notes: 1. If vertical fenestration or skylight area exceeds maximum allowed per C402.3.1, then Target Area Adjustment of all applicable envelope
elements will be calculated by the compliance form. Refer to Target Area Adjustments worksheet for this calculation.
2. U- factors shall come from Appendix A, Chapter C303, or calculated per approved method as specified in C402.1.2.
Building Component
Proposed UA
Target UA
Provide source of U- factor, page/plan # of assembly detail & ID
U- factor x Area A = UA (U x A
U- factor x Area (A ) UA U x A)
Y
R= ID:
0.034 2580 87.7
Above Deck Insulation U -0.034
R= 30 ID: A3.40
0.034
2580
87.7
R= ID:
R= ID:
0.031
w
0
07
R= ID:
Metal Building U -0.031
R= ID:
R= ID:
0.021 3735 78.4
r
R= ID: A3.40
0.027 3735
100.8
Single raft, attic, other U -0.021
R= ID:
R= ID:
0.055
R= ID:
Steel /metal frame U -0.055
R= ID:
°
o
a
R= ID:
0.052
0°
R= ID:
Metal Building U -0.052
N
R= ID:
Co
R =21 ID: A3.40
0.054
7657
413.5
0.054
7657
413.5
Wood Frame, other U -0.054
=3
o
R= ID:
C7
n
0
3:
R= ID:
O
R= ID:
0.104
N
R= ID:
Mass Wall U -0.104
R= ID:
w
R= ID:
0.104
m
o
R= ID:
Assumed to be Mass Wall U -0.104
m �
R= ID:
i
(D
R= ID:
W
R= ID:
0.031
Mass Floor U -0.031
m
R= ID:
o
R= ID:
°
R= ID:
0.029
Joist/Framing U -0.029
m F
R= ID:
ti
R= ID:
F- factor ! x Perimeter
= UA(U x A)
F- factor x Perimeter = UA (U x A)
R= ID:
0.540
d
°
m
r
R= ID:
Slab -On -Grade U -0.54
�'
c
R= ID:
n
R=10 ID: A3.40
0.550
402 221.1
0_550 402 221.1
co
a
R= ID:
Heated Slab -On -Grade U -0.55
=
R= ID:
*Proposed non - residential CMU walls meeting Table C402.1.2 Area UA Area UA
Footnote D requirements can use the target U -value of 0.104 rather Page 1
than Appendix A values. Show footnote requirements in plans. Subtotal 14374 823 14374 801 :1
Component Performance Compliance (UA) UA COMPLIES
2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3
Revised Oct 2013
Project Address Olympia Federal savings Yelm
Date 08/04/2014
Fenestration Area as % gross above -grade wall area 16.396 Max. Target: 30.0%
For Building Department Use
Skylight Area as % gross roof area Max. Target: 5.0%
Notes: 1. If vertical fenestration or skylight area exceeds maximum allowed per C402.3.1, then Target
Area Adjustment of all applicable envelope elements will be calculated by the compliance form.
Refer to Target Area Adjustments worksheet for this calculation.
2: Provide NFRC rated U- factor or default U- factor from Appendix A for the fenestration assembly
thermal performance (combination of frame and glazing).
3: Fenestration that separates conditioned space from a non - conditioned or semi - conditioned
Building Component
Proposed UA
Target UA
Provide source of U- factor, page /plan # of assembly detail & ID
U- factor x Area (A) = UA (U x A )
U- factor x Area (A) = UA (U x A)
U= ID:
0.37
3 $
U= ID:
Opaque Swing Doors U -0.37
cn o
U= ID:
C N
U= ID:
0.37
Opaque rollup & sliding U -0.37
0
U= ID:
o
U= ID:
@
U= ID:
0.30
Non -Metal Frame U -0.30
U= ID:
o
U= ID:
Z
U= ID:
y
U= ID: A3.40
0.35 1486 520.1
0.38 1486 564.7
w—x
U= ID:
Metal Frame, Fixed U -0.38
N
Y
U= ID:
c
a�
2
U= ID:
- L
d
U= ID:
0.40
ca
°_
U= ID:
Metal Frame, Operable U -0.40
U= ID:
U= ID:
L
U= ID:
0.60
m
U= ID:
Metal Entrance Door U -0.60
C:
U= ID:
}
U= ID:
U= ID:
0.50
1-12-)
U= ID:
All types U -0.50
~_
U= ID:
Q
U= ID:
Area UA Area UA
Page 2 Subtotal
To comply: Page 1 Subtotal
1) Proposed Total UA shall not exceed Target Total UA.
2) Proposed Total Area shall equal Target Total Area. Total
1486
520
14374
823
15860
1343
1486 565
14374 801
15860 1365
Component Performance Compliance (UA) UA COMPLIES
If vertical fenestration area exceeds maximum allowed per Section C402.3.1, then Target Area Adjustment of all applicable envelope elements is
required. This worksheet automatically calculates these adjustments and updates target areas in the ENV -UA and ENV -SHGC worksheets. Information
shown in this worksheet is for reference only and is write- protected. Submit this Target Area Adjustment form with ENV -UA and ENV -SHGC forms.
VF = Vertical fenestration NW = Net above grade wall (excludes fenestration and doors.)
DR = Opaque doors Gross Exterior Above -Grade Wall Area= VF + NW + DR
AG = Above -grade
Proposed Areas
Vertical Fenestration -
Opaque -
VF= 1486.0
(C402.3. 1)
NW= 7657.0
1 DR=
Gross Exterior Max Vert. Fen. % Maximum Target
AG Wall Area
(C402.3. 1)
Vert. Fen. Area
9143.0
X 30.0 - 100 =
2742.9
Total Vertical
Delta Vertical
0
Excess Vertical
Fenestration
Maximum Target
Fenestration
Fenestration
1486.0 1 - 1 2742.9 1 = - 1256.9 II greater
Vertical Fenestration
Non -metal frame
Metal frame, fixed
Metal frame, operable
Metal frame, entrance door
Above -grade Wall
Steel Frame
Metal Building
Wood I Other frame
Mass
Proposed Area Target VF Mult. Target Area
X -
1486.0 X 1.00 = 1486.0
X -
X Target areas in shaded
Proposed Area Target Net Wall Mult. Target Area boxes are applied to target
_ areas on ENV -UA
X -
7657.0 X 1.00 = 7657.0
X -
Sum of Proposed 1 9143.0 Sum of Target
SHGC x A Adjustments
Non -North Vertical Fenestration
PF < 0.2
0.2 :5 PF <0.5
PF ? 0.5
North Vertical Fenestration
PF < 0.2
0.2 <_ PF < 0.5
PF ? 0.5
Sum of target above -grade
9143 . 0 wall and vertical
fenestration areas are
calculated to equal the sum
of proposed
Proposed Area Target VF Mult. Target Area
1275.0 X 1.00 = 1275.0
X -
X -
211.0 X 1.00 = 211.0
X -
X -
SHGC target areas in
shaded boxes are applied
to target areas on ENV -
SHGC
- 1256.9 I
Multiplier applied to all
Total Vertical
Excess Vertical Target Vertical
Total Vertical
Proposed Vertical
Fenestration Areas to
Fenestration
1486.0
Fenestration Fenestration
- = 1486.0
Fenestration
- 1486.0
Target VF Multiplier
= 1.00
calculate Target Vertical
Fenestration Area
Net AG Wall Area
Excess Fenestration Target Net Wall Area
Net Wall
Target Net Wall Mult.
Multiplier applied to all
7657.0
+ = 7657.0
7657.0
= 1.00
Proposed Opaque Above -
-
Grade Wall Areas to
UA Adjustments
calculate Target Above-
Vertical Fenestration
Non -metal frame
Metal frame, fixed
Metal frame, operable
Metal frame, entrance door
Above -grade Wall
Steel Frame
Metal Building
Wood I Other frame
Mass
Proposed Area Target VF Mult. Target Area
X -
1486.0 X 1.00 = 1486.0
X -
X Target areas in shaded
Proposed Area Target Net Wall Mult. Target Area boxes are applied to target
_ areas on ENV -UA
X -
7657.0 X 1.00 = 7657.0
X -
Sum of Proposed 1 9143.0 Sum of Target
SHGC x A Adjustments
Non -North Vertical Fenestration
PF < 0.2
0.2 :5 PF <0.5
PF ? 0.5
North Vertical Fenestration
PF < 0.2
0.2 <_ PF < 0.5
PF ? 0.5
Sum of target above -grade
9143 . 0 wall and vertical
fenestration areas are
calculated to equal the sum
of proposed
Proposed Area Target VF Mult. Target Area
1275.0 X 1.00 = 1275.0
X -
X -
211.0 X 1.00 = 211.0
X -
X -
SHGC target areas in
shaded boxes are applied
to target areas on ENV -
SHGC
Skylight Target Area Adjustment Calculations
If skylight area exceeds maximum allowed per Section C402.3.1, then Target Area Adjustment of all applicable envelope elements is required. This
worksheet automatically calculates these adjustments and updates target areas in the ENV -UA and ENV -SHGC worksheets. Information shown in this
SKY= Skylight I NR - Net roof excludes skylight) Gross Exterior Roof Area = SKY + NR
Proposed Areas
Skylight (Horizontal Fenestration) -> SKY=
Opaque Roof -I NR= 6315.0
Gross Exterior
Max Skylight %
Maximum Skylight
Roof Area
(C402.3.1)
Excess Skylight Target Skylight Area
Fenestration Area
6315.0 1
X 5.0%
— 100 =
315.8
Total Skylight Area
— Maximum Tar et
315.8
— Delta Skylight Area
-315.8 J
0
B greater
— Excess Sk li ht
_
F
alculatel'Target
-315.8
-J
UA and SHGC x A Adjustments
Skylight Proposed Area
All
Roof Proposed Area
Insulation Above Deck 2580.0
Metal Building
Attic/ All Others 3735.0
Sum of Proposed 6315. 0
Target SL Mult. Target Area
X I J —D
Target Net Wall Mult. Target Area Target areas in shaded
boxes are applied to target
X 1.00 = 2580.0 areas on ENV -UA
X
X 1.00 = 3735.0
Sum of target roof and
skylight areas are
Sum of Target 6315.0
g calculated to equal the sum
ofproposed
Total Skylight Area
Excess Skylight Target Skylight Area
Total Skylight Area
Target SL Multiplier
Proposed Skylight kylig t to all
Pr000 as
J
—
_
F
alculatel'Target
-J
Skylight Area
Net Roof Area
6315.0
Excess Skylight Target Net Roof Area
+ = 6315.0
Net Roof
- 6315. 0
Target Net Roof Mult.
= 1 .00
Proposl ed Opaq etRoof
Areas to calculate Target
UA and SHGC x A Adjustments
Skylight Proposed Area
All
Roof Proposed Area
Insulation Above Deck 2580.0
Metal Building
Attic/ All Others 3735.0
Sum of Proposed 6315. 0
Target SL Mult. Target Area
X I J —D
Target Net Wall Mult. Target Area Target areas in shaded
boxes are applied to target
X 1.00 = 2580.0 areas on ENV -UA
X
X 1.00 = 3735.0
Sum of target roof and
skylight areas are
Sum of Target 6315.0
g calculated to equal the sum
ofproposed
ation Zones •
gn1 g \Araehinntnn Rtata Fnornv rnda rmmnlianra Fnrms fnr rnmmerrial R[ ilrfinnc inrludinn R7 & R3 nver 3 Stnries and all R1 Revised Oct 2013
Project Address Olympia Federal savings Yelm
Date 08/04/2014
0 16.3% Max. Target: 30%
Fenestration Area as /o gross above -grade wall area 9
For Building Department Use
Skylight Area as % gross roof area Max. Target: 5%
Vertical Fenestration Alternates: None Selected on ENV -SUM
Notes: 1 - Proposed vertical fenestration and skylight areas entered in ENV -SHGC must match proposed
fenestration areas in ENV -UA.
x Area (A) = SHGC x
2 - If Target Area Adjustment is required per ENV -UA, then target areas will be automatically
0.40
adjusted in ENV -SHGC. Refer to Target Area Adjustments worksheet for this calculation.
510.0
3 - Provide NFRC rated SHGC or default from Table C303.1.3(3) for fenestration assembly SHGC.
0.48
4 - Fenestration that separates conditioned space from a non - conditioned or semi - conditioned
space shall be included in this worksheet.
0.64
Skylights Proposed SHGC
Target SHGC
Provide source of SHGC, page /plan # of assembly detail & ID SHGC x Area (A) = SHGC x P
SHGC x Area (A) = SHGC x A
ID:
0.35
SHGC 0.35
ID:
ID:
ID:
ID:
Totals
Totals
All Non -North Vertical Fenestration+
Provide source of SHGC, page /plan # of assembly
detail & ID
ID: A3.10
ID: A3.11
ID:
ID:
ID:
ID:
ID:
ID:
ID:
ID
Proposed SHGC
PF SHGC' x Area (A) = SHGC x
0 0.27 408 110
0 0.27 867 1 234
0
0 I
0
0
0
0
0
0
++ If projection factor (PF) credits are
applied to the proposed design, Target
SHGC will sum fenestration area by PF
category.
+ If projection factor credit is applied, then vertical Totals 1275. 0 344.3 Totals 1275.0 510.0
fenestration must be entered in the correct table according to
orientation. If credit is not applied then all vertical
fenestration can be entered in either table.
Note: Fenestration that separates conditioned space from a
non - conditioned or semi - conditioned space shall be listed
here with a proposed SHGC equal to the target value.
North Vertical Fenestration+
Provide source of SHGC, page /plan # of assembly
detail & ID
Proposed SHGC
PF SHGC' x Area (A) = SHGC x
0 0.27 211 57
0
0
0
0
0
0
North Total 211.0 57 .0
Target SHGC ++
PF
SHGC
x Area (A) = SHGC x F
Category
SHGC
x Area (A) = SHGC x
IF < Q,2
0.40
1275
510.0
25PF <0.5
0.48
IF? .5
0.64
++ If projection factor (PF) credits are
applied to the proposed design, Target
SHGC will sum fenestration area by PF
category.
+ If projection factor credit is applied, then vertical Totals 1275. 0 344.3 Totals 1275.0 510.0
fenestration must be entered in the correct table according to
orientation. If credit is not applied then all vertical
fenestration can be entered in either table.
Note: Fenestration that separates conditioned space from a
non - conditioned or semi - conditioned space shall be listed
here with a proposed SHGC equal to the target value.
North Vertical Fenestration+
Provide source of SHGC, page /plan # of assembly
detail & ID
Proposed SHGC
PF SHGC' x Area (A) = SHGC x
0 0.27 211 57
0
0
0
0
0
0
North Total 211.0 57 .0
++ If projection factor (PF) credits are applied
to the proposed design, Target SHGC will sum
fenestration area by PF category.
211.0 1 84.4
Area JSHGCxAJ Area I SHGC x A
To comply, the Proposed total SHGC x A for all fenestration (vertical Total rrannd 1486.0 401.2 Total 1486.0 594.4
& skylights) shall not exceed the Target total SHGC x A.
Target SHGC ++
PF
SHGC
x Area (A) = SHGC x F
Category
PF < 0.2-
0.40
211
84.4
D.25PF <0.5
0.44
PF z 0.5
0.48
++ If projection factor (PF) credits are applied
to the proposed design, Target SHGC will sum
fenestration area by PF category.
211.0 1 84.4
Area JSHGCxAJ Area I SHGC x A
To comply, the Proposed total SHGC x A for all fenestration (vertical Total rrannd 1486.0 401.2 Total 1486.0 594.4
& skylights) shall not exceed the Target total SHGC x A.
Component Performance Compliance (SHGC) SHGC COMPLIES
Building Permit Plans Checklist, ••
2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1
Project Address Olympia Federal savings Yelm Date 8/4/2014
The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State Energy
Code, Commercial Provisions.
Applicability
Code
Location in
Building
(yes,no,na)
Section
Component
Compliance information required in permit documents
Documents
Department Notes
SCOPE
na
C101.5.2
Low energy spaces
Low energy spaces identified on plans
na
na
1
Semi - heated spaces
Semi - heated spaces identified on plans
C102.1.4
na
C402.5
Cooler and freezer
Walk -in and refrigerated warehouse cooler and freezer spaces identified on
na
C402.6
spaces
plans
na
na
C101.4.6
Mixed occupancy
Spaces with different occupancy requirements identified on plans
na
Change of
Existing F, S and U- occupancy building spaces undergoing a change of
r,a
C101A 4
occupancy /space
occupancy or space conditioning that require compliance are identified on
C101.4.5
conditioning
plans
na
ENVELOPE PROVISIONS
na
C303.1
Insulation
Indicate identification mark shall be applied to all insulation materials
identification
na
C303.1.3
Fenestration product
Fenestration products shall be labeled with rated U- factor, SHGC, VT, and
na
C402.4.3
rating
leakage rating
na
Indicate installation methods, thicknesses, densities and clearances to achieve
C303.1.1
General insulation
the intended R -value of all insulation_ materials;
yes
C402.2
installation
Where two or more layers of rigid insulation will be used, indicate that edge
joints between layers are staggered
A3.40
Indicate R- value(s) of cavity /continuous insulation on roof sections;
Indicate framing materials on roof sections,
Indicate method of framing for ceilings below vented attics and vaulted ceilings
yes
C402.2.1
Roof assembly
er A102.2 std, advv);
insulation
— - - —
Provide area - weighted calculations for sloped insulation installed entirely above
deck;
Indicate R- values for thermal spacers and each insulation layer, and liner
system LS method for metal building roofs
A3.40
Skylight curb
Indicate curb insulation R -value on roof section if not included in skylight NFRC
na
C402.2.1
insulation
rating
na
Indicate R- value(s) of cavity /continuous insulation on wall sections;
Indicate framing materials on wall sections;
Indicate method of framing for wood const per A103.2 (std, int, adv),
C402.2.3
yes
C40224
Above /below grade
wall insulation
- --
Indicate mass of masonry walls;
C303.2.1
Indicate loose -fill core insulation material, percentage of cores filled, and
frequency of grouted cores and bond beams for masonry walls;
Indicate method of protection of exposed exterior basement/crawlspace wall
insulation
A3.40
Walk -in /refrigerated
Indicate insulation R- values of ceilings, walls, doors, Floors on sections;
Indicate method of minimizing door infiltration,
na
C402.5
warehouse cooler
C402.6
and freezer insulation
Indicate type(s) of transparent doors and windows
na
Indicate rated U- factor (swinging) or R -value (roll -up /sliding) on wall sections -
na
C402.2.7
Opaque doors
applies to doors with less than 50% lazed area
na
Floor over outdoor or
Indicate R- value(s) of cavity /continuous insulation on floor sections._
Indicate framing material on Floor sections,
na
C402.2.5
unconditioned space
insulation
na
Indicate mass of masonry floors
Indicate R -value of continuous insulation on wall section or foundation detail,
C402.2.6
Slab -on -grade floor
Indicate insulation extends down vertically and /or horizontally the required
yes
C303.2.1
insulation
distance from top of slab;
Indicate method of protection of exposed exterior slab edge insulation
A3.40
Indicate R -value of continuous insulation on wall section or foundation detail,
na
C402.2.6
Radiantly heated slab-
on -grade floor
Indicate insulation extends down vertically from top of slab and then horizontally
C303.2.1
insulation
under the entire slab;
- - - -- — - - - --
Indicate method of protection of exposed exterior slab edge insulation
na
Radiant heating
Indicate insulation R -value behind radiant panels, U- bend /headers and bottom
na
C402.2.8
system insulation
surface of radiantly heated floors other than radiantly heated slab-on-grade)
na
Building Permit Plans Checklist, ••
2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1
Project Address Olympia Federal Savings Yelm
Date 8/4/2014
Applicability
Code
Location in
Building
(yes,no,na)
Section
Component
Compliance information required in permit documents
Documents
Department Notes
Vertical fenestration
Provide calculation for total vertical fenestration area as percentage of gross
na
C402.3.1
maximum area
above grade wall area
na
na
C402.3.1.2
Skylight maximum
area
Provide calculation for total skylight area as percentage of gross roof area
na
Indicate U- factors, SHGC and VT values in fenestration schedules;
C402.3.3
U- factors, SHGC and
An area - weighted U -value may be used for all fenestration elements that qualify
na
C402.3.1.3
VT for all fenestration
within the same fenestration category per Table C402.3;
C303.1.3
assemblies
Indicate if values are NFRC or default. If default then specify frame type,
qlazinq layers, gap width, low -e coatings, as -fill.
na
Provide calculations showing that percentage of overall conditioned floor area
C402.3.1.1
Increased max.
in the daylight zone is equal to or greater than 50 %; --
na
Chap. 2
vertical fenestration
area with daylighting
Indicate method of daylighting control in lighting equipment schedules;
Definition
controls
na
Indicate VT of vertical fenestration is at least 1.1 times the rated SHGC
Increased max.
Indicate high performance U- factors and SHGC values in fenestration
na
C402.3.1.2
vertical fenestration
schedules,
area with high-
An area - weighted U -value may be used for all fenestration elements that qualify
performance glazing
within the same fenestration category r this section
na
C402.3.3
Permanent shading
Provide projection factor calculations (Equation C4 -2) and associated SHGC
na
C402.3.3.1
devices
multipliers for north and non -north orientations
na
Provide calculations for percentage of conditioned floor area located within a
skylight daylight zone; _ _
Provide calculations for percentage of skylight area to daylight zone under
na
C402.3.2
Single story spaces
skylights, OR
YIi 9
Provide calculations for percentage of overall skylight effective aperture
requiring skylights
Equation
Indicate haze factor of skylight glazing material or diffuser
na
AIR LEAKAGE
Air barrier
Indicate location of continuous air barrier on plans and sections;
na
C402.4.1.1
construction and
Provide details for all joints, transitions in materials, penetrations in air barrier
C402.4.2
sealing
and note method of sealing caulked, gasketed, or other approved method
na
Indicate locations of all stairway and shaft vents,
Provide leakage rating of motorized dampers in mechanical equipment
Stairway and shaft
na
C402.4.5.1
vents
schedules, _
Indicate method of emergency operation - activation of fire alarm or interruption
of power
na
Indicate locations of all outside air intakes, exhausts and relief outlets, including
Outdoor air intakes,
those integral to mechanical equipment;
yes
C402.4.5.2
exhausts and relief
Provide in mechanical equipment schedules leakage rating of dampers, identify
openings
whether motorized or gravity, and note any exceptions taken
M2.0
Recessed lighting in
Indicate IC rating of fixtures in lighting equipment schedules;_ _
na
C402.4.8
building envelope
na
Indicate method of sealing between light fixture housing and wall or ceiling
na
C402.4.6
Loading dock seals
Indicate weather seal at cargo and loading dock doors
na
Indicate locations and dimensions of vestibules;
For unconditioned vestibules, indicate which envelope assembly (interior or
yes
C402.4.7
Vestibules
exterior ) complies with the requirements for a conditioned space
x.2.10
Indicate air barrier test method in accordance with ASTM E779 or approved
equivalent;
Include the following requirements in project documents: (1) air barrier test
r.a
C402.4 -
Air barrier building
report shall be submitted to jurisdiction once test is completed; (2) if test results
.1.2.3
test
exceed 0.4 cfm /ft2 at 0.3 in. wg then visually inspect air barrier and seal noted
sources of leakage; (3) submit a follow -up report to jurisdiction noting corrective
measures taken
na
It "no" is selected for any question, provide explanation:
End of Building Permit Plans Checklist