Loading...
20140164 Energy Summary 080520142012 Washinaton State Enerav Code Compliance Forms for Commercial Buildings includinq R2 & R3 over 3 stories and all R1 Revised Oct 2013 Commercial Provision Chapters 1 - 5 of the 2012 Washington State Energy Code apply to all commercial occupancies, R -2 and R -3 occupancies greater than 3 stories above grade, and R -1 occupancy (all building heights). Intro This file, ENV12- v3.XLSM, has electronic compliance forms for envelope provisions as defined in Sections C101, C303, C402 and Appendix A for Climate Zones 4c and 5b. There are two companion files: LTG12- v3.XLSM (Section C405 lighting, motor, and transformer requirements), and MECH12- v3.XLSM (Section C403 mechanical systems requirements). This form is a compliance aid and is not a substitute for the full energy code text or specific jurisdiction compliance Energy Code requirements. Users should refer to the code text and contact the local jurisdiction for complete information. The full 2012 WSEC code text is available for download from the NEEC website: htto: /www. neec. neVeneray -codes Training Refer to the NEEC website for instruction on how to complete all of the 2012 WSEC Compliance Forms. Start -up Select this file from the NEEC website to download to your computer. When opening the file be sure to Enable Macros. This file is an Excel workbook that contains multiple compliance forms and resources in Excel worksheets. Each Overview worksheet is indicated by a tab at the bottom of the screen. You may visit each worksheet by selecting it's tab. Most calculations are automated. Cells that display informational text and the results of calculations are write - protected and cannot be edited. Save Files This file is saved in the same manner as any standard Excel file. Getting Some forms have two pages. Both pages are available on screen when you select the tab for a form (worksheet). Use Around the scroll bars to find the second page located below the first page. All general project information and the date are entered once on ENV -SUM. This information is automatically replicated on all other ENV forms. The ENV -SUM form accompanies all other ENV forms. Only input cells are accessible. If you try to edit a write- protected cell an error message will appear requesting a password. A password IS NOT required to complete these forms. You may use the TAB key to move to the next input cell. If the TAB doesn't take you where you want to go, use your mouse to move around the form. Avoid excessively long text strings when entering information. In some cases, text that extends beyond the available Input Cells space will not be visible. In most cases the text will wrap within the cell. This may force part of the form onto a new page. To enter the date, use this format: mm /dd /yyyy. For example, you would enter 7/1/2013 or 12/21/2014. Check boxes can be checked or unchecked by clicking in the box with your mouse. Radio buttons (circles) allow only one in a set to be selected. Drop -down lists have an arrow at the right side of the cell. Click on the arrow with your mouse and select the appropriate option. Use the delete button on your computer to clear a drop -down entry. When a form has a space for notes or explanation, click anywhere in the space to edit. Personalizing You can personalize the forms with your company name, address, phone, or any other information. This is done by editing the header or footer in Excel. Many tables, such as for listing envelope assembly types, have a certain number of lines available for entering data. Adding Lines You may need more lines to enter all your information. Where this feature is available, you can add additional lines to the and table by selecting the 'Y' button on the right hand side of the table with your mouse. If you can't see the 'Y' button, scroll to the right or increase the View Zoom setting for the worksheet. Removing To remove lines that you have added, select the "" button with your mouse. You cannot remove lines that were not added; an error message will appear if you try. If you add additional lines with this method, the pagination may be affected forcing the forms to carry additional lines over to other pages. Be sure to submit all pages to the plans examiner. Compliance You must select a Compliance Path on ENV -SUM (line 12) to activate the correct input method for Window -to -Wall Path and Skylight -to -Roof ratios. Occupancy You must select an Occupancy Group on ENV -SUM (line 14) for this workbook to display the correct code ,Group requirements and automatically calculate component performance target UA values. 2012 Washinaton State Enerav Code Compliance Forms for Commercial Buildinas includina R2 & R3 over 3 stories and all R1 Revised Oct 2013 For projects complying via the Prescriptive Path, enter the vertical fenestration area, gross wall area (includes vertical fenestration, doors, etc), skylight area and gross roof area (includes skylights, mechanical equipment curbs, etc) directly Fenestration into the Vertical Fenestration and Skylight Area Calculation input cells on the ENV -SUM form. The form will calculate Area the Window -to -Wall and Skylight -to -Roof ratios. For projects complying via the Component Performance Path, the Vertical Fenestration and Skylight Area inputs in the ENV -SUM form are write protected. Enter all applicable envelope information in the ENV -UA form. The resulting Window -to -Wall and Skylight-to-Roof ratios will auto fill into the ENV -SUM form from the ENV -UA form. The prescriptive vertical fenestration target area is 30 %. This target increases to 40% if the project complies with the Vertical requirements of either C402.3.1.1 50% floor area within the daylight zone, or C402.3.1.3 high performance vertical Fenestration fenestration. Alternates If the project is eligible for one of these alternates, select the corresponding button on Line 24 of the ENV -SUM form. This will re- calculate the prescriptive target area in the ENV -SUM and ENV -UA forms based on 40 %. Target Area Adjustment is required if the project exceeds the prescriptive target area for vertical fenestration or Target Area skylights. Adjusted target areas are automatically calculated in the ENV -UA form using envelope assembly areas you Adjustment enter for your project. Adjusted target areas will appear in the Target UA column in the ENV -UA form. Refer to Target Area Ad ustment worksheet for the supporting calculations. The forms should print on any printer supported by your operating system. You will need to have the following TrueType fonts installed under Windows: Arial, Times New Roman, Courier New and Wingdings. These are all standard Windows fonts. If you are losing form details when printing, you may have a shortage of printer memory. Try printing problem pages individually. Printing By default, only the active worksheet is printed. To print more than one worksheet at a time, open your print set -up menu and select either the page range you wish to print or Entire Workbook. Forms (worksheets) in a workbook may not be deleted because the file is locked. To print blank forms to fill out by hand, delete all of the heading information at the beginning of ENV -SUM and select Blank Forms the desired Occupancy Group. For each radio button group there is a button labeled "Clear." Clicking this button will clear the other buttons so that they will print as empty circles. The "Clear' button will not print. End of Instructions for Electronic Forms 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Oct 2013 Project Info Project Address Olympia Federal savings Yelm Date 8/4/2014 Compliance forms Corner of Yelm Ave. & xanoma Blvd. For Building Department Use do not require a password to use. Instructional and Applicant Name: Sunset Air, Inc. calculating cells are write - protected. Applicant Address: 5210 Lacey BLVD SE, Lacey WA 98503 Applicant Phone: 360 -456 -4956 Project Description 21 New Building ❑ Addition ❑ Alteration ❑ Change of Occupancy /Conditioning Compliance Path O Prescriptive O Component Performance O Total Building Performance Selection required to enable forms. Occupancy Group OO Commercial O Group R - R2 & R3 over 3 stories and all R1 Selection required to enable forms. Vertical Fenestration and Total Vertical Gross Exterior Skylight Area Calculation Fenestration Above Grade % Vertical If complying via the Prescriptive path, (rough opening) divided by Wall Area times 100 equals Fenestration 1486.0 — 9143.0 X 100 - 16.3 $ enter values for vertical fenestration, skylights, gross walls and roof on this ENV -SUM worksheet. Ifcomplying via the Component Performance path, enter Gross Exterior these values in the ENV -UA worksheet. Total Skylight divided by Roof Area times 100 equals % Skylight These values auto-fill from ENV -UA and are write - protected on ENV -SUM. 0.0 _ 6315.0 X 100 = 0.0% Fenestration Area Vertical VERTICAL FENESTRATION AREA COMPLIES Fenestration Area Compliance Skylight Area SKYLIGHT AREA COMPLIES Vertical Fenestration O 50% or more of the floor area is within a daylight zone per C402.3.1.1 Alternates O High Performance Fenestration U- factors and SHGC per C402.3.1.3 Compliance Method ❑ Skylight area 3% or greater, VT -0.40 or greater Single Story Spaces ❑ Skylight effective aperture 1% or greater, provide calculation Requiring Skylights ❑ Space eligible for exception Requires a minimum of 50% of floor area to be within a skylight daylight zone for specific space types. Refer to C402.3.2 for requirements. ❑ Project has semi - heated spaces as defined per C402.1.4 ❑ Applying wall exception to semi - heated spaces 1. Semi - heated spaces may comply under Prescriptive or Component Performance compliance Semi - Heated Spaces path. 2. Semi - heated spaces shall be documented separately from other conditioned spaces– provide separate compliance forms for each conditioned space type. 3. Envelope elements separating semi - heated from other conditioned spaces shall comply with exterior thermal envelope requirements. [I Walk -in Cooler ❑ Walk -in Freezer El Refrigerated Warehouse Cooler E] Refrigerated Warehouse Freezer Refrigerated Spaces Refrigerated spaces shall comply under the Prescriptive Path only. Compliance documentation for these areas maybe combined with non - refrigerated areas in the ENV - PRESCRIPTIVE form. Refer to C402.5 and C402.6 for requirements. Project includes more than one occupancy type and /or level of space conditioning. Multiple Mixed Occupancy and/or compliance forms maybe required. Select all that apply to scope of project: Space Conditioning El Commercial ❑ R2 & R3 over 3 stories and all R1 ❑ Refrigerated Space ❑ Fully Conditioned ❑ Semi - Heated ❑ Low Energy* ❑ R2 & R3 - 3 stories or less *Low energy areas are exempt from all thermal envelope provisions and compliance forms for these areas are not required. Refer to C101.5.2 for exemption. 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R Revised Oct 2013 Minimum Req uirements This table summarizes prescriptive compliance requirements for opaque elements and fenestration. Refer for Prescriptive Compliance to Tables C402.1.2, C402.2 and C402.3 in the 2012 WSEC for important footnotes that apply to these tables. Refer to Section C402 for all applicable requirements that apply for each envelope element type and applicable exceptions. Prescriptive Path Table C402.2 Notes 1,7 Insulation Minimum R -Value Table C402.1.2 Notes 1,2 Assembly Maximum U- factor Occupancy Group All Other Group R All Other Group R Opaque Elements Roofs Insulation Entirely above Deck R -30 c.i. R -38 6. U -0.034 U -0.031 Metal Building with R -3.5 thermal blocks) Note 3 R -25 + R -I 1 Ls R -25 + R -11 Ls U4031 U -0.031 Attic and Other R -49 R49 U -0.021 U -0.021 Walls, Above -grade Mass R -9.5 c.i. R -13.3 c.i. U -0.104 Note 6 U -0.078 Metal Building R -13 + R -13 c.i. R -13 + R -13 c.i. U -0.052 U -0.052 Steel Framed R -13 + R- 10c.i. R -19 + R -8.5 c.i. U -0.055 U -0.055 Wood Framed and Other R -21 int R -21 int U -0.054 U -0.054 Below Grade Wall Note 4 Same as above grade Same as above grade Floors Mass R -30 c.i. R -30 c.i. U -0.031 U -0.031 Steel Joist R -38 + R -10 c.i. R -38 + R -10 c. i. U -0.029 U -0.029 Wood Framed and Other R -30 R -30 U -0.029 U -0.029 Slab -On -Grade Floors Unheated R -10 for 24 in. (from top of slab) F -0.54 F -0.54 Heated Note 5 R -10 perimeter & under entire slab F -0.55 F -0.55 Opaque Doors Swinging No R -Value for prescriptive compliance. U -0.37 U -0.37 Roll-up or sliding R-4.75 I R -4.75 No U -Value for prescriptive compliance. Table C402.3 - 0-30% of wall area, or 30%-40110 per Section C402.3.1.1 DLZ Section C402.3. L3 High Performance Fenestration Option - 040% of wall area Fenestration Assembly Maximum U- factor Notes 1,2 Vertical Fenestration Nonmetal framing U -0.30 U -0.30 U -0.28 U -0.28 Metal framing (fixed) U -0.38 U -0.38 U -0.34 U -0.34 Metal framing (operable) U -0.40 U -0.40 U -036 U -0.36 Entrance doors U -0.60 U -0.60 U -0.60 U -0.60 Skylights Skylights U -0.50 U -0.50 U -0.50 U -0.50 Fenestration Assembly Maximum SHGC Factor Vertical Fenestration PF < 0.2: all orientations - SHGC -0.40 0.2 <_ PF < 0.5: north - SHGC -0.44; all other - SHGC -0.48 PF ? 0.5: north - SHGC -0.48; all other - SHGC -0.64 PF < 0.2: all orientations - SHGC -0.35 0.2 <_ PF < 0.5: north - SHGC - 0385; all other - SHGC -0.42 PF ? 0.5: north - SHGC -0.42; all other - SHGC -0.56 Skylights SHGC -0.35 SHGC -0.35 Refrigerated Spaces Insulation Insulation Minimum R -Value Table C402.5 and C402.6 Assembly Maximum U- factor Freezers - Walk -in and Warehouse Roof/ Ceiling R -32 No U -Value for prescriptive compliance Wall R -32 Door R -32 Door - transparent reach -in triple -pane, heat - reflective treated or gas Floor R -28 Coolers - Walk -in and Warehouse Roof/ Ceiling R -25 No U -Value for prescriptive compliance Wall R -25 Door R -25 Door - transparent reach -in double -pane, heat - reflective treated & gas fill, or comply with freezer door req. Floor No Requirement 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R rceviseo Definitions: Ls = Liner system -- A continuous membrane installed below the purlins and uninterrupted by framing members. Uncompressed, unlaced insulation rests on top of the membrane between the purlins. Refer to Section A 1012.5.4. e.i. = Continuous insulation -- Insulation that is continuous across all structural members without thermal bridges other than service openings and penetrations by metal fasteners with a x- sectional area of less than 0.04% of the opaque surface area of the assembly. int = Intermediate framing -- Includes insulated headers, comers and interior partition wall to exterior wall intersections. Refer to Section A103.2 for framing definitions. Footnote Summary: Each table in the 2012 WSEC has footnotes applicable to specific information provided in the table. This footnote summary provides only abbreviated details from these footnotes. Refer to 2012 WSECfor completefootnote information. 1 - Assembly descriptions can be found in Chapter 2 and Appendix A. 2 - Use of assembly U- factors, C- factors and F- factors from Appendix A and Chapter 3 are required unless otherwise allowed by the provisions of this Code. 3 - For metal building roofs where using R -value compliance method, a thermal spacer block is required. Otherwise use the U- factor compliance method. 4 - Where heated slabs are below - grade, below -grade walls shall comply with the exterior insulation requirements for heated slabs. 5 - Heated slab F- factors shall be determined specifically for heated slabs. Unheated slab F- factors shall not be used. 6 - Non - residential CMU walls may be eligible to use Table C402.1.2 U- factor if all provisions stated in applicable footnote are met. Refer to Footnote D in Table C402.1.2 or Footnote C in Table C402.2 for eligibility requirements. 7 - Roof, wall or Floor assemblies required to have continuous insulation may be eligible for alternate continuous insulation R- values if all provisions in applicable footnote are met. Refer to Footnote F in Table C402.2 for eligibility requirements. End of Envelope Requirements Summary 2012 Washinaton State Enerav Code Compliance Forms for Commercial Buildings includinq R2 & R3 over 3 stories and all R1 Revised Oct 2013 Project Address of J Olympia Federal Savings Yelm Date 08/04/2014 Occupancy Group OO Commercial O Group R For Building Department Use Change in occupancy or space conditioning O Note - Proposed UA may exceed Target UA by 10% per C101.4.4 and C101.4.5 Fenestration Area as % gross above -grade wall area 16.3% Max. Target: 30.0% Skylight Area as % gross roof area 0.0% Max. Target: 5.0% Vertical Fenestration Alternates: None Selected on ENV -SUM Notes: 1. If vertical fenestration or skylight area exceeds maximum allowed per C402.3.1, then Target Area Adjustment of all applicable envelope elements will be calculated by the compliance form. Refer to Target Area Adjustments worksheet for this calculation. 2. U- factors shall come from Appendix A, Chapter C303, or calculated per approved method as specified in C402.1.2. Building Component Proposed UA Target UA Provide source of U- factor, page/plan # of assembly detail & ID U- factor x Area A = UA (U x A U- factor x Area (A ) UA U x A) Y R= ID: 0.034 2580 87.7 Above Deck Insulation U -0.034 R= 30 ID: A3.40 0.034 2580 87.7 R= ID: R= ID: 0.031 w 0 07 R= ID: Metal Building U -0.031 R= ID: R= ID: 0.021 3735 78.4 r R= ID: A3.40 0.027 3735 100.8 Single raft, attic, other U -0.021 R= ID: R= ID: 0.055 R= ID: Steel /metal frame U -0.055 R= ID: ° o a R= ID: 0.052 0° R= ID: Metal Building U -0.052 N R= ID: Co R =21 ID: A3.40 0.054 7657 413.5 0.054 7657 413.5 Wood Frame, other U -0.054 =3 o R= ID: C7 n 0 3: R= ID: O R= ID: 0.104 N R= ID: Mass Wall U -0.104 R= ID: w R= ID: 0.104 m o R= ID: Assumed to be Mass Wall U -0.104 m � R= ID: i (D R= ID: W R= ID: 0.031 Mass Floor U -0.031 m R= ID: o R= ID: ° R= ID: 0.029 Joist/Framing U -0.029 m F R= ID: ti R= ID: F- factor ! x Perimeter = UA(U x A) F- factor x Perimeter = UA (U x A) R= ID: 0.540 d ° m r R= ID: Slab -On -Grade U -0.54 �' c R= ID: n R=10 ID: A3.40 0.550 402 221.1 0_550 402 221.1 co a R= ID: Heated Slab -On -Grade U -0.55 = R= ID: *Proposed non - residential CMU walls meeting Table C402.1.2 Area UA Area UA Footnote D requirements can use the target U -value of 0.104 rather Page 1 than Appendix A values. Show footnote requirements in plans. Subtotal 14374 823 14374 801 :1 Component Performance Compliance (UA) UA COMPLIES 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 Revised Oct 2013 Project Address Olympia Federal savings Yelm Date 08/04/2014 Fenestration Area as % gross above -grade wall area 16.396 Max. Target: 30.0% For Building Department Use Skylight Area as % gross roof area Max. Target: 5.0% Notes: 1. If vertical fenestration or skylight area exceeds maximum allowed per C402.3.1, then Target Area Adjustment of all applicable envelope elements will be calculated by the compliance form. Refer to Target Area Adjustments worksheet for this calculation. 2: Provide NFRC rated U- factor or default U- factor from Appendix A for the fenestration assembly thermal performance (combination of frame and glazing). 3: Fenestration that separates conditioned space from a non - conditioned or semi - conditioned Building Component Proposed UA Target UA Provide source of U- factor, page /plan # of assembly detail & ID U- factor x Area (A) = UA (U x A ) U- factor x Area (A) = UA (U x A) U= ID: 0.37 3 $ U= ID: Opaque Swing Doors U -0.37 cn o U= ID: C N U= ID: 0.37 Opaque rollup & sliding U -0.37 0 U= ID: o U= ID: @ U= ID: 0.30 Non -Metal Frame U -0.30 U= ID: o U= ID: Z U= ID: y U= ID: A3.40 0.35 1486 520.1 0.38 1486 564.7 w—x U= ID: Metal Frame, Fixed U -0.38 N Y U= ID: c a� 2 U= ID: - L d U= ID: 0.40 ca °_ U= ID: Metal Frame, Operable U -0.40 U= ID: U= ID: L U= ID: 0.60 m U= ID: Metal Entrance Door U -0.60 C: U= ID: } U= ID: U= ID: 0.50 1-12-) U= ID: All types U -0.50 ~_ U= ID: Q U= ID: Area UA Area UA Page 2 Subtotal To comply: Page 1 Subtotal 1) Proposed Total UA shall not exceed Target Total UA. 2) Proposed Total Area shall equal Target Total Area. Total 1486 520 14374 823 15860 1343 1486 565 14374 801 15860 1365 Component Performance Compliance (UA) UA COMPLIES If vertical fenestration area exceeds maximum allowed per Section C402.3.1, then Target Area Adjustment of all applicable envelope elements is required. This worksheet automatically calculates these adjustments and updates target areas in the ENV -UA and ENV -SHGC worksheets. Information shown in this worksheet is for reference only and is write- protected. Submit this Target Area Adjustment form with ENV -UA and ENV -SHGC forms. VF = Vertical fenestration NW = Net above grade wall (excludes fenestration and doors.) DR = Opaque doors Gross Exterior Above -Grade Wall Area= VF + NW + DR AG = Above -grade Proposed Areas Vertical Fenestration - Opaque - VF= 1486.0 (C402.3. 1) NW= 7657.0 1 DR= Gross Exterior Max Vert. Fen. % Maximum Target AG Wall Area (C402.3. 1) Vert. Fen. Area 9143.0 X 30.0 - 100 = 2742.9 Total Vertical Delta Vertical 0 Excess Vertical Fenestration Maximum Target Fenestration Fenestration 1486.0 1 - 1 2742.9 1 = - 1256.9 II greater Vertical Fenestration Non -metal frame Metal frame, fixed Metal frame, operable Metal frame, entrance door Above -grade Wall Steel Frame Metal Building Wood I Other frame Mass Proposed Area Target VF Mult. Target Area X - 1486.0 X 1.00 = 1486.0 X - X Target areas in shaded Proposed Area Target Net Wall Mult. Target Area boxes are applied to target _ areas on ENV -UA X - 7657.0 X 1.00 = 7657.0 X - Sum of Proposed 1 9143.0 Sum of Target SHGC x A Adjustments Non -North Vertical Fenestration PF < 0.2 0.2 :5 PF <0.5 PF ? 0.5 North Vertical Fenestration PF < 0.2 0.2 <_ PF < 0.5 PF ? 0.5 Sum of target above -grade 9143 . 0 wall and vertical fenestration areas are calculated to equal the sum of proposed Proposed Area Target VF Mult. Target Area 1275.0 X 1.00 = 1275.0 X - X - 211.0 X 1.00 = 211.0 X - X - SHGC target areas in shaded boxes are applied to target areas on ENV - SHGC - 1256.9 I Multiplier applied to all Total Vertical Excess Vertical Target Vertical Total Vertical Proposed Vertical Fenestration Areas to Fenestration 1486.0 Fenestration Fenestration - = 1486.0 Fenestration - 1486.0 Target VF Multiplier = 1.00 calculate Target Vertical Fenestration Area Net AG Wall Area Excess Fenestration Target Net Wall Area Net Wall Target Net Wall Mult. Multiplier applied to all 7657.0 + = 7657.0 7657.0 = 1.00 Proposed Opaque Above - - Grade Wall Areas to UA Adjustments calculate Target Above- Vertical Fenestration Non -metal frame Metal frame, fixed Metal frame, operable Metal frame, entrance door Above -grade Wall Steel Frame Metal Building Wood I Other frame Mass Proposed Area Target VF Mult. Target Area X - 1486.0 X 1.00 = 1486.0 X - X Target areas in shaded Proposed Area Target Net Wall Mult. Target Area boxes are applied to target _ areas on ENV -UA X - 7657.0 X 1.00 = 7657.0 X - Sum of Proposed 1 9143.0 Sum of Target SHGC x A Adjustments Non -North Vertical Fenestration PF < 0.2 0.2 :5 PF <0.5 PF ? 0.5 North Vertical Fenestration PF < 0.2 0.2 <_ PF < 0.5 PF ? 0.5 Sum of target above -grade 9143 . 0 wall and vertical fenestration areas are calculated to equal the sum of proposed Proposed Area Target VF Mult. Target Area 1275.0 X 1.00 = 1275.0 X - X - 211.0 X 1.00 = 211.0 X - X - SHGC target areas in shaded boxes are applied to target areas on ENV - SHGC Skylight Target Area Adjustment Calculations If skylight area exceeds maximum allowed per Section C402.3.1, then Target Area Adjustment of all applicable envelope elements is required. This worksheet automatically calculates these adjustments and updates target areas in the ENV -UA and ENV -SHGC worksheets. Information shown in this SKY= Skylight I NR - Net roof excludes skylight) Gross Exterior Roof Area = SKY + NR Proposed Areas Skylight (Horizontal Fenestration) -> SKY= Opaque Roof -I NR= 6315.0 Gross Exterior Max Skylight % Maximum Skylight Roof Area (C402.3.1) Excess Skylight Target Skylight Area Fenestration Area 6315.0 1 X 5.0% — 100 = 315.8 Total Skylight Area — Maximum Tar et 315.8 — Delta Skylight Area -315.8 J 0 B greater — Excess Sk li ht _ F alculatel'Target -315.8 -J UA and SHGC x A Adjustments Skylight Proposed Area All Roof Proposed Area Insulation Above Deck 2580.0 Metal Building Attic/ All Others 3735.0 Sum of Proposed 6315. 0 Target SL Mult. Target Area X I J —D Target Net Wall Mult. Target Area Target areas in shaded boxes are applied to target X 1.00 = 2580.0 areas on ENV -UA X X 1.00 = 3735.0 Sum of target roof and skylight areas are Sum of Target 6315.0 g calculated to equal the sum ofproposed Total Skylight Area Excess Skylight Target Skylight Area Total Skylight Area Target SL Multiplier Proposed Skylight kylig t to all Pr000 as J — _ F alculatel'Target -J Skylight Area Net Roof Area 6315.0 Excess Skylight Target Net Roof Area + = 6315.0 Net Roof - 6315. 0 Target Net Roof Mult. = 1 .00 Proposl ed Opaq etRoof Areas to calculate Target UA and SHGC x A Adjustments Skylight Proposed Area All Roof Proposed Area Insulation Above Deck 2580.0 Metal Building Attic/ All Others 3735.0 Sum of Proposed 6315. 0 Target SL Mult. Target Area X I J —D Target Net Wall Mult. Target Area Target areas in shaded boxes are applied to target X 1.00 = 2580.0 areas on ENV -UA X X 1.00 = 3735.0 Sum of target roof and skylight areas are Sum of Target 6315.0 g calculated to equal the sum ofproposed ation Zones • gn1 g \Araehinntnn Rtata Fnornv rnda rmmnlianra Fnrms fnr rnmmerrial R[ ilrfinnc inrludinn R7 & R3 nver 3 Stnries and all R1 Revised Oct 2013 Project Address Olympia Federal savings Yelm Date 08/04/2014 0 16.3% Max. Target: 30% Fenestration Area as /o gross above -grade wall area 9 For Building Department Use Skylight Area as % gross roof area Max. Target: 5% Vertical Fenestration Alternates: None Selected on ENV -SUM Notes: 1 - Proposed vertical fenestration and skylight areas entered in ENV -SHGC must match proposed fenestration areas in ENV -UA. x Area (A) = SHGC x 2 - If Target Area Adjustment is required per ENV -UA, then target areas will be automatically 0.40 adjusted in ENV -SHGC. Refer to Target Area Adjustments worksheet for this calculation. 510.0 3 - Provide NFRC rated SHGC or default from Table C303.1.3(3) for fenestration assembly SHGC. 0.48 4 - Fenestration that separates conditioned space from a non - conditioned or semi - conditioned space shall be included in this worksheet. 0.64 Skylights Proposed SHGC Target SHGC Provide source of SHGC, page /plan # of assembly detail & ID SHGC x Area (A) = SHGC x P SHGC x Area (A) = SHGC x A ID: 0.35 SHGC 0.35 ID: ID: ID: ID: Totals Totals All Non -North Vertical Fenestration+ Provide source of SHGC, page /plan # of assembly detail & ID ID: A3.10 ID: A3.11 ID: ID: ID: ID: ID: ID: ID: ID Proposed SHGC PF SHGC' x Area (A) = SHGC x 0 0.27 408 110 0 0.27 867 1 234 0 0 I 0 0 0 0 0 0 ++ If projection factor (PF) credits are applied to the proposed design, Target SHGC will sum fenestration area by PF category. + If projection factor credit is applied, then vertical Totals 1275. 0 344.3 Totals 1275.0 510.0 fenestration must be entered in the correct table according to orientation. If credit is not applied then all vertical fenestration can be entered in either table. Note: Fenestration that separates conditioned space from a non - conditioned or semi - conditioned space shall be listed here with a proposed SHGC equal to the target value. North Vertical Fenestration+ Provide source of SHGC, page /plan # of assembly detail & ID Proposed SHGC PF SHGC' x Area (A) = SHGC x 0 0.27 211 57 0 0 0 0 0 0 North Total 211.0 57 .0 Target SHGC ++ PF SHGC x Area (A) = SHGC x F Category SHGC x Area (A) = SHGC x IF < Q,2 0.40 1275 510.0 25PF <0.5 0.48 IF? .5 0.64 ++ If projection factor (PF) credits are applied to the proposed design, Target SHGC will sum fenestration area by PF category. + If projection factor credit is applied, then vertical Totals 1275. 0 344.3 Totals 1275.0 510.0 fenestration must be entered in the correct table according to orientation. If credit is not applied then all vertical fenestration can be entered in either table. Note: Fenestration that separates conditioned space from a non - conditioned or semi - conditioned space shall be listed here with a proposed SHGC equal to the target value. North Vertical Fenestration+ Provide source of SHGC, page /plan # of assembly detail & ID Proposed SHGC PF SHGC' x Area (A) = SHGC x 0 0.27 211 57 0 0 0 0 0 0 North Total 211.0 57 .0 ++ If projection factor (PF) credits are applied to the proposed design, Target SHGC will sum fenestration area by PF category. 211.0 1 84.4 Area JSHGCxAJ Area I SHGC x A To comply, the Proposed total SHGC x A for all fenestration (vertical Total rrannd 1486.0 401.2 Total 1486.0 594.4 & skylights) shall not exceed the Target total SHGC x A. Target SHGC ++ PF SHGC x Area (A) = SHGC x F Category PF < 0.2- 0.40 211 84.4 D.25PF <0.5 0.44 PF z 0.5 0.48 ++ If projection factor (PF) credits are applied to the proposed design, Target SHGC will sum fenestration area by PF category. 211.0 1 84.4 Area JSHGCxAJ Area I SHGC x A To comply, the Proposed total SHGC x A for all fenestration (vertical Total rrannd 1486.0 401.2 Total 1486.0 594.4 & skylights) shall not exceed the Target total SHGC x A. Component Performance Compliance (SHGC) SHGC COMPLIES Building Permit Plans Checklist, •• 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Project Address Olympia Federal savings Yelm Date 8/4/2014 The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State Energy Code, Commercial Provisions. Applicability Code Location in Building (yes,no,na) Section Component Compliance information required in permit documents Documents Department Notes SCOPE na C101.5.2 Low energy spaces Low energy spaces identified on plans na na 1 Semi - heated spaces Semi - heated spaces identified on plans C102.1.4 na C402.5 Cooler and freezer Walk -in and refrigerated warehouse cooler and freezer spaces identified on na C402.6 spaces plans na na C101.4.6 Mixed occupancy Spaces with different occupancy requirements identified on plans na Change of Existing F, S and U- occupancy building spaces undergoing a change of r,a C101A 4 occupancy /space occupancy or space conditioning that require compliance are identified on C101.4.5 conditioning plans na ENVELOPE PROVISIONS na C303.1 Insulation Indicate identification mark shall be applied to all insulation materials identification na C303.1.3 Fenestration product Fenestration products shall be labeled with rated U- factor, SHGC, VT, and na C402.4.3 rating leakage rating na Indicate installation methods, thicknesses, densities and clearances to achieve C303.1.1 General insulation the intended R -value of all insulation_ materials; yes C402.2 installation Where two or more layers of rigid insulation will be used, indicate that edge joints between layers are staggered A3.40 Indicate R- value(s) of cavity /continuous insulation on roof sections; Indicate framing materials on roof sections, Indicate method of framing for ceilings below vented attics and vaulted ceilings yes C402.2.1 Roof assembly er A102.2 std, advv); insulation — - - — Provide area - weighted calculations for sloped insulation installed entirely above deck; Indicate R- values for thermal spacers and each insulation layer, and liner system LS method for metal building roofs A3.40 Skylight curb Indicate curb insulation R -value on roof section if not included in skylight NFRC na C402.2.1 insulation rating na Indicate R- value(s) of cavity /continuous insulation on wall sections; Indicate framing materials on wall sections; Indicate method of framing for wood const per A103.2 (std, int, adv), C402.2.3 yes C40224 Above /below grade wall insulation - -- Indicate mass of masonry walls; C303.2.1 Indicate loose -fill core insulation material, percentage of cores filled, and frequency of grouted cores and bond beams for masonry walls; Indicate method of protection of exposed exterior basement/crawlspace wall insulation A3.40 Walk -in /refrigerated Indicate insulation R- values of ceilings, walls, doors, Floors on sections; Indicate method of minimizing door infiltration, na C402.5 warehouse cooler C402.6 and freezer insulation Indicate type(s) of transparent doors and windows na Indicate rated U- factor (swinging) or R -value (roll -up /sliding) on wall sections - na C402.2.7 Opaque doors applies to doors with less than 50% lazed area na Floor over outdoor or Indicate R- value(s) of cavity /continuous insulation on floor sections._ Indicate framing material on Floor sections, na C402.2.5 unconditioned space insulation na Indicate mass of masonry floors Indicate R -value of continuous insulation on wall section or foundation detail, C402.2.6 Slab -on -grade floor Indicate insulation extends down vertically and /or horizontally the required yes C303.2.1 insulation distance from top of slab; Indicate method of protection of exposed exterior slab edge insulation A3.40 Indicate R -value of continuous insulation on wall section or foundation detail, na C402.2.6 Radiantly heated slab- on -grade floor Indicate insulation extends down vertically from top of slab and then horizontally C303.2.1 insulation under the entire slab; - - - -- — - - - -- Indicate method of protection of exposed exterior slab edge insulation na Radiant heating Indicate insulation R -value behind radiant panels, U- bend /headers and bottom na C402.2.8 system insulation surface of radiantly heated floors other than radiantly heated slab-on-grade) na Building Permit Plans Checklist, •• 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Project Address Olympia Federal Savings Yelm Date 8/4/2014 Applicability Code Location in Building (yes,no,na) Section Component Compliance information required in permit documents Documents Department Notes Vertical fenestration Provide calculation for total vertical fenestration area as percentage of gross na C402.3.1 maximum area above grade wall area na na C402.3.1.2 Skylight maximum area Provide calculation for total skylight area as percentage of gross roof area na Indicate U- factors, SHGC and VT values in fenestration schedules; C402.3.3 U- factors, SHGC and An area - weighted U -value may be used for all fenestration elements that qualify na C402.3.1.3 VT for all fenestration within the same fenestration category per Table C402.3; C303.1.3 assemblies Indicate if values are NFRC or default. If default then specify frame type, qlazinq layers, gap width, low -e coatings, as -fill. na Provide calculations showing that percentage of overall conditioned floor area C402.3.1.1 Increased max. in the daylight zone is equal to or greater than 50 %; -- na Chap. 2 vertical fenestration area with daylighting Indicate method of daylighting control in lighting equipment schedules; Definition controls na Indicate VT of vertical fenestration is at least 1.1 times the rated SHGC Increased max. Indicate high performance U- factors and SHGC values in fenestration na C402.3.1.2 vertical fenestration schedules, area with high- An area - weighted U -value may be used for all fenestration elements that qualify performance glazing within the same fenestration category r this section na C402.3.3 Permanent shading Provide projection factor calculations (Equation C4 -2) and associated SHGC na C402.3.3.1 devices multipliers for north and non -north orientations na Provide calculations for percentage of conditioned floor area located within a skylight daylight zone; _ _ Provide calculations for percentage of skylight area to daylight zone under na C402.3.2 Single story spaces skylights, OR YIi 9 Provide calculations for percentage of overall skylight effective aperture requiring skylights Equation Indicate haze factor of skylight glazing material or diffuser na AIR LEAKAGE Air barrier Indicate location of continuous air barrier on plans and sections; na C402.4.1.1 construction and Provide details for all joints, transitions in materials, penetrations in air barrier C402.4.2 sealing and note method of sealing caulked, gasketed, or other approved method na Indicate locations of all stairway and shaft vents, Provide leakage rating of motorized dampers in mechanical equipment Stairway and shaft na C402.4.5.1 vents schedules, _ Indicate method of emergency operation - activation of fire alarm or interruption of power na Indicate locations of all outside air intakes, exhausts and relief outlets, including Outdoor air intakes, those integral to mechanical equipment; yes C402.4.5.2 exhausts and relief Provide in mechanical equipment schedules leakage rating of dampers, identify openings whether motorized or gravity, and note any exceptions taken M2.0 Recessed lighting in Indicate IC rating of fixtures in lighting equipment schedules;_ _ na C402.4.8 building envelope na Indicate method of sealing between light fixture housing and wall or ceiling na C402.4.6 Loading dock seals Indicate weather seal at cargo and loading dock doors na Indicate locations and dimensions of vestibules; For unconditioned vestibules, indicate which envelope assembly (interior or yes C402.4.7 Vestibules exterior ) complies with the requirements for a conditioned space x.2.10 Indicate air barrier test method in accordance with ASTM E779 or approved equivalent; Include the following requirements in project documents: (1) air barrier test r.a C402.4 - Air barrier building report shall be submitted to jurisdiction once test is completed; (2) if test results .1.2.3 test exceed 0.4 cfm /ft2 at 0.3 in. wg then visually inspect air barrier and seal noted sources of leakage; (3) submit a follow -up report to jurisdiction noting corrective measures taken na It "no" is selected for any question, provide explanation: End of Building Permit Plans Checklist