20140179 Rev Cmts from BCRA 10172014 � ; , � � 2706 Paciflc Avenue,Suttn. 3qo iac�m�t.WA 98402 � T(7531 627 4367 � / October 17,2014 Karen Bennett City of Yelm Community Development Department 105 Yelm Avenue West Yelm, WA 98597 Dear Karen, Attached are our revised plans and responses to review comments provided on October 6t", 2014 by Jim Gibson of SCJ Alliance. Please feel free to contact me if you have any questions or would like to discuss the project further. Water Svstem Comments 1. Fire flow calculations have not been supplied with the review material. Please provide the calculations per the SUP approval BCRA Response: Acknowledged,fire flow testing was provided to us by Kevin Ray on October 13, 2014 and confirmed the following; Flowrate=1,095 GPM Static Pressure=51 psi Residual Pressure=45 psi Converting this to the standard 20 psi pressure an equivalent flowrate is found X �H \os4 R QR — QF H�� QR = Rated Capacity at 20 psi (gpm) QF = Total Test Flow (gpm) NR = Static Pressure minus 20 psi (psi) HF = Static Pressure mtinus Residual Pressure (psi) C51 psi — 20 psi\o.s4 QR = 1,095 gpm x I = 2,658 gpm 51 psi — 45 psi/ This flow rate exceeds the flowrate required in the 1012 International Fire Code Table 8105.1 (a type V-8 structure between 4,801 and 6,200 square feet)of�,000 gpm. 2. Under "Utility Notes" page C1.01 it states"Fire protection lines to be designed and completed by fire protection engineer." BCRADESIGN.COM ��^ �x . � �.�. #� � ;� � � f , � � �,�i -�..�-.:�...,..,� - � �. ;� � �,,,,. .. . o-���.,.. ; �; �� , ,,� �, �� �� .. �� ,. � , � � . ; � �� ���. � .,, � � � *.� � .,. � � ,�» �_..., `v� � x . . � "*�--��.,..�.. , , � . �. r , "...� »� �. . �, . . � �, _,>. � . ...... `��..,_,. .._,. � . � � 2106 Pacitic Rvenue,.Suii�� �300 � (,.xpma,WA 96962 i 12`i3i 677 436f � D BCRA Response: Acknowledged, note has been removed. 3. If fire flow cannot be provided by only fire hydrants, a fire sprinkler may be required. If this is necessary the plans must show the fire sprinkler supply line, post indicator valve, (PIV),fire department connection (FDC), FDC supply and a fire hydrant location for use with the FDC connection. BCRA Response: Adequate fire flow has been confirmed per response above. 4. The current Fire hydrant does not meet the requirements for building coverage to all parts of the building with a maximum 150' hose pull. BCRA Response: We will work with Gary Carlson to petition for waiver of regulation. Fire hydrant is currently positioned such that a hose pull of 167'would be required to reach all parts of the building. 5. Is the water main large enough to support the required fire flow requirements?Support the 6" size with fire flow calculations. BCRA Response: Adequate fire flow has been confirmed per response above. Sewer Svstem Comments 1. The construction plans are vague at the connection point. It may be in conflict with existing water supply lines, meter and back flow prevention. BCRA Response: Acknowledged, plans have been modified to provide connection to existing system in an area free of obstructions. 2. The service line needs to be checked for the added flows of the new service line connection. BCRA Response: The existing service line is a 2"line, it is our opinion that this line is adequate for connection. 3. The tank depth from rim to invert should not be more than 5 feet.This is a City policy. Page 2 of 6 � . �i � � 2206 PaCiflc Avenuf>.Su+te ;�iSi � iac��rrra,WA 9HaU2 T{2531 627 4367 � D BCRA Response: Acknowledged,plans have been modified to provide adequate cover over service line and STEP tank. 4. Typically STEP tank sizing does not allow for the reduction of tank size because of"flow duration". By using a 3/8 flow duration reduction it appears to undersize the tank. BCRA Response: The project is classified as a religious education facility, used on Sundays for the duration of the religious service(approximated to be 3 hours). Under the DOE's Criteria for Sewage Works Design (Orange BookJ the nearest facility designation would be "Schools with no showers and with a cafeteria". This was determined to be highly conservative given the lack of a cafeteria within the proposed structure as well as its hours of use. Given this information, we determined that a reduction factor could be applied to negate a portion of the oversizing due to the conservative nature of the calculations. Similarly,STEP tank performance for another STEP tank on the project site,serving a larger demand was considered. Based on these factors we believe, using our engineering judgment, the proposed STEP tank is appropriately sized for the application. 5. Typical sizing should be Q=(GPD/person)(persons)(2.0 non res) Using this the flow would be 2,400 detention volume. BCRA Response: Acknowledged, see above response. 6. If the owner has plans for future expansion or more intensive uses (more people)for this location you may want to add additional storage to the tank. BCRA Response: Acknowledged,see above response. 7. The City requires 24 hours of storage above the working volume. BCRA Response: BCRA Response: Acknowledged,see above response. 8. A generator switch and receptacle is required to be installed on the control panel. See City sewer addendum notes. Page 3 of 6 � � � 2106 Paciti�Avenue Su�te 300 (acoma.WA �8402 � T(253)627�43�i1 � � BCRA Response: Callout has been amended to include, "Furnish and install transfer switch model DT 323 URK as manufactured by Cutler Hammer and male plug mode170530 MBWP manufactured by eryant." 9. A hose bib is required to be within 50 feet of the STEP tank for maintenance. BCRA Response: A hose bib is provided near the entrance to the building, refer to MEP plans for details. 10. City requires the standard float levels to be utilized in the STEP Tank designs. Please do not customize the float levels for your design. BCRA Response: STEP system report as well as details on plans have been updated to exclude modified float elevations. General Comments on Plans 1. Please add the survey bench mark, basis of bearings, and vertical datum to all plan sheets the reference elevations. BCRA Response: Acknowledged, survey information has been added to the plan sheet. Stormwater Pollution Prevention Plan 1. City of Yelm uses 2012 DOE Stormwater Manual.All references should be changed to 2012 manual. We have reviewed the design under the 2012 manual and have no comments for drainage system. BCRA Response: Reference to the 2005 DDE Stormwater Manual has been updated to the 2012 DOE Stormwater Manual. Review of the Conditions of Approval dated Au�ust 12.2014 1. Please provide an estimate of water usage. Page 4 of 6 � !!1 iui� W 2'106 pacific AvFrrue S�,�t:, , . , T<3eorn<� WA 984U2 � T 1753t 62z-43�i7 � / BCRA Response: Work to obtain this is currently in process, will be provided prior to final approval of plans 2. A waiver of protest is required for frontage improvements. BCRA Response: Work to obtain this is currently in process, will be provided prior to final approval of plans 3. A detailed landscape plan needs to be reviewed by the City staff. BCRA Response: Work to obtain this is currently in process, will be provided prior to final approval of plans 4. Submit a fire hydrant plan consistent with Yelm Development Guide for hydrant spacing. BCRA Response: Work to obtain this is currently being done, will be provided prior to final approval of plans 5. Submit fire flow calculations for review. BCRA Response: Refer to response to Water System Comment#1 for fire flow calculations. Plan Comments 1. 2" gate valve shown but not recorded (noted). BCRA Response: Callout has been updated to include reference to gate valve. 2. Water meter needs to be accessible 24/7 and not behind gate. BCRA Response: Water meter has been relocated outside the gated areo, near the parking area. Page 5 of 6 � � � 2 i06 P3c.ifit RvErnuw� Suitar �ii�;� � 1,��oma,WA 9NAG2 T(�5 31 627-4 36�1 � / 3. STEP tank needs to be moved closure to bldg. so it's not so deep. It looks over 5'from inlet I.E. to finished grade. 3' of cover on a non-traffic rated tank is the max. per manufacturer's warranty BCRA Response: See response to Sewer System Comment#3 above. 4. Need to verify line size at hook-up point to determine method of connection. BCRA Response: Line size and material has been added to the plan callout. 5. Need submittals for tank and appurtenances, also include all details pertinent to this project. BCRA Response: Details have been updated to include all pertinent details. 6. Need water spigot within 50' of farthest tank lid for maintenance. BCRA Response: See response to Sewer System Comment#9 above. 7. Show location of pump control panel. BCRA Response: Detail has been added to clarify location of pump control panel. Thank you for providing us the review comments. Please feel free to contact me if there are any questians or if there is a need to further discuss the project. Sincerely, ��� Oct 17 2074 11:14 AM lustin Goroch, PE Page 6 of 6