20150136 Permit Pkg 03112015City of Yelm
Community Development Department
Building Division
Phone: (360) 458-8407
Fax: (360) 458 -3144
Applicant:
Name: CENEX HARVEST STATES
Address: PO BOX 518
AUBURN WA 98071
Property Information:
Site Address: x(19 RH0T0N RIB 4F
Assessor Parcel No.: 22719240500
Contractor Information:
Name: G.O. CONSTRUCTION, LLC
Address: KELLY GRANGER
PO BOX 1536
YELM WA 98597
Contractor License No.:
Project Information:
Project: NEW COMMERCIAL BUILDING
Description of Work:
Sq. Ft. per floor: First 192
Second
Third
Garage
Basement
Permit No.: 20150136
Issue Date: 3/11/2015
(Work must be completed within 180 days)
Phone: 253 - 833 -7220
Owner: CHS, INC
Subdivision: Lot:
Phone:
Expires: 0 /00 /0000
Heat Type (Electric, Gas, Other):
Fees:
Item Contractor
NEW COMMERCIAL BUILDING G.O. CONSTRUCTION, LLC
TOTAL FEES:
Applicant's Affidavit:
I certify that I have read and examined the information contained within the application and know the same
to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of
Yelm regulations including those governing zoning and land subdivision, and in addition, all covenants,
easements and restrictions of record. If applying as a contractor, I further certify that I am currently
registered in the State of Washington.
Signature - Y-c - Date
Firm
Fees
$ 211.16
$ 211.16
OFFICIAL USE ONLY
# Sets of Prints:
Final Inspection:
Date:
By:
Cit -3244
REC #: 00189227 3/11/2015 2:26 PM
OPER: CO TERM: 001
REF #: 675100
PAID BY:
TRAN: 33.0000 BUILDING PERMITS
20150136
CENEX HARVEST STATES
509 RHOTON RD 211.16CR
BLD -COM1
TENDERED: 211-16 .16- CHECK
APPLIED:
CHANGE: 0.00
CITY OF YELM
COMMERCIAL BUILDING PERMIT APPLICATION FORM
Project Address: 5bet GE *12tNbTj=.,J * 220 12, 05
1 11M
1 %%: Parcel
Zoning,- j oue__,� Current Use: 1\1 Proposed Use: 5Tf1ZA&gAF;r/,-E__-
New Construction ri Re-Model / Re-Roof / Tenant Improvement
I7 PrUmbing D Mechanical 0 Fire Prevent/Suppress/Alarm 0 Other
Project Description/Scope of Work: L2,Y
Project Value:_.
BuildingArea (sq. ft) Parking Garage 15' Floor 2nd Floor 3rd Floor
Building feight KL-j2_,.1AL*, Hflu_i-t-,
Are there any environmentally sensitive areas located on the parcel? � If yes, a
completed environmental checklist must accompany permit application.
BUILDING OWNER/TENANT NAME: C.-Jarl-,
ADDRESS 25t CM ST. 9.0- EMAIL r it f-i-is-
CITY AA_u R_�.a _STATE_ZIP -
J%C%7_TELEPHONE 513'l, - -7ZZx,:;,
ARCHITECT/ENGINEER LICENSE #_
ADDRESS —EMAIL
CITY STATE ZIP TELEPHONE
GENERAL CONTRACTOR
_ TELEPHONE
ADDRESS JZ
EMAIL
CITY STATE -OX ZIP ag�,.F
CONTRACTOR'S LICENSE %CtZ.- In- Jsj(,o EXP LICENSE#
PLUMBING CONTRACTOR t,5t& TELEPHONE
ADDRESS EMAIL
CITY STATE ZIP FAX
CONTRACTOR'S LICENSE # EXP DATE CITY LICENSE #
MECHANICAL CONTRACTOR A TELEPHONE
ADDRESS —EMAIL
CITY STATE ZIP FAX
CONTRACTOR'S LICENSE # EXP DATE CITY LICENSE #
Copy of City Mitigation documentation (TFC).
I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the
above described property will be in accordance with the laws, rules and regulations of the State of Washington and the
City of Yelm.
Applicant's Signature Date
Owner I Contractor/ Owner's Agent, Contractor's 0%.LVI's Agent/ Tenant (Please circle one.)
All permits are non-transferable and will expire if work authorized by such permit is not begun
within 180 days of issuance, or if work is suspended or abandoned for a period of 180 days
(360) 458-3835
105 Yelin Aue W
Yelin, WA 98597 (360) 458-3144 FAX
MAR 04 2015 'xi.yelm.wa.us
, r"Kj-
, If
MAR 04 2015
k
r
EZTT2 SEo: 00000
EXTERIOR SGL DOOR PREHUNG
310x6/8 6P TS210 RIGHT HAND INSWING
(B), DB BORE 2-'3/8" B/S 2- 118", 6 9/16"
PNT GRD EXT JAMB, MILL COMP FXD SILL,
11111111111111111111111 lililillil 111111 lill lill
U6227098
�e
Y °
N
1
qzr
q:T
0
W
Z
Cl-!
O
O
00
O
N
LO
O
r
• • • • • • • •
r, A r c c.,— fr,r cr,rr,r„Prr ni Riiildinns includina R2 & R3 over 3 stories and all R1 Revised Oct 2013
"Proposed non - residential CMU walls meeting Table C402.1.2 Area UA Area UM
Footnote D requirements can use the target U -value of 0.104 rather Page 1
than Appendix A values. Show footnote requirements in plans. Subtotal 832 51 832 34
Component Performance Compliance (UA) UA DOES NOT COMPLY
Date 05/21/2013
Project Address 509 Rhoton Road
Occupancy Group * Commercial O Group R
For Building Department Use
Change in occupancy or space conditioning O
Note - Proposed UA may exceed Target UA by 10% per C101.4.4 and C101.4.5
Fenestration Area as % gross above -grade wall area Max. Target: 40.0%
Skylight Area as % gross roof area Max. Target: 5.0%
Vertical Fenestration Alternates: High Performance Vertical Fenestration
Notes. 1: If vertical fenestration or skylight area exceeds maximum allowed per C402.3.1, then Target Area Adjustment of all applicable envelope
elements will be calculated by the compliance form. Refer to Target Area Adjustments worksheet for this calculation.
2: U- factors shall come from Appendix A, Chapter C303, or calculated per approved method as specified in C402.1.2.
Building Component
Proposed UA
Target UA
Provide source of U- factor, page /plan # of assembly detail & ID
U- factor x Area (A) = UA (U x A )
U- factor x Area (A) = UA (U x A)
R= ID:
0.034
Above Deck Insulation U-0,034
Y
a)
R= ID:
0
R= ID:
a
R= ID:
0.031
Metal Building U -0.031
o
m
R= ID:
2
R= ID:
= 49 ID: Truss at 24 "o.c.
0 . 020 192 3 . 8
0 . 021 192 4 . 0
Single raft, attic, other U -0.021
ff
= ID:
= ID:
R= ID:
0.055
Steel /metal frame U -0.055
R= ID:
R= ID:
'o
a
R= ID:
0.052
Metal Building U -0.052
Q
m
R_ ID:
N
R= ID:
`°
r
R= 21 ID: 2X6 wall 16" o.c.
0.047 448 21.1
0.054 448 24.2
Wood Frame, other U -0.054
o
R_ ID:
Q
o
R= ID:
0
R= ID:
0.104
Mass Wall U -0.104
Cn Cn
R= ID:
R= ID:
w
R= ID:
0.104
Assumed to be Mass Wall U -0.104
o 3:
R= ID:
m m
R= ID:
0
R= ID:
Cn
R= ID:
0.031
Mass Floor U -0.031
V)
R= ID:
o
R= ID:
-o
R= ID:
0.134 192 25.7
0.029 192 5.
Joist/Framing U -0.029
E
�
R= ID:
I LL
R= ID:
F- factor x Perimeter = UA(U x A)
F- factor x Perimeter = UA (U x A)
R= ID:
0.540
Slab -On -Grade U -0.54
C'
R= ID:
Co
R= ID:
Q
R= ID:
0.550
Heated Slab -On -Grade U -0.55
R= ID:
=
R= ID:
"Proposed non - residential CMU walls meeting Table C402.1.2 Area UA Area UM
Footnote D requirements can use the target U -value of 0.104 rather Page 1
than Appendix A values. Show footnote requirements in plans. Subtotal 832 51 832 34
Component Performance Compliance (UA) UA DOES NOT COMPLY
2012 Washington State Energy Code Compliance Forms for Cnmmarrfal RIriILiinnc ;— iI,.ji— oo Q n�
-- - - "' - -• -• •-- �••...y.s .viuu,y 1\L u 1 \J VVCI
Project Address 509 Rhoton Road
RtlV- V.1Zu IJ
Date
05/21/2013
Fenestration Area as % gross above -grade wall area Max. Target: 40.0
For Building Department Use
Skylight Area as % gross roof area Max. Target: 5.0$
Notes: 1. If vertical fenestration or skylight area exceeds maximum allowed per C402.3.1, then Target
Area Adjustment of all applicable envelope elements will be calculated by the compliance form.
Refer to Target Area Adjustments worksheet for this calculation.
2. Provide NFRC rated U- factor or default U- factor from Appendix A for the fenestration assembly
thermal performance (combination of frame and glazing).
3: Fenestration that separates conditioned space from a non - conditioned or semi - conditioned
Building Component
Proposed UA
Target UA
Provide source of U- factor, page /plan # of assembly detail & ID
U- factor x Area (A) = UA (U x A
U- factor x Area (A) = UA (U x A)
rn L U= ID:30x68
°
0.160 17 2.7
0.37 17 6.3
'S U= ID:
3: 0
(0 o
Opaque Swing Doors U -0.37
U= ID:
CL In
U= ID:
0.37
�
U= ID:
Opaque rollup & sliding U -0.37
U= ID:
U= ID:3030
0.31 9 2.8
0.28 9 2.5
U= ID:
Non -Metal Frame U -0.28
o
U= ID:
Z
U= ID:
U= ID:
0.34
o
m
U= ID:
Metal Frame, Fixed U -0.34
m
U= ID:
N
Q
a)
U= ID:
a)
LL
Q
U= ID:
m
U
U= ID:
0.36
Metal Frame, Operable U -0.36
m
Z
U= ID-
2
U= ID:
U= ID:
0.60
m
U= ID:
Metal Entrance Door U -0.60
a
U= ID:
:E
U= ID:
In
In
U= ID:
0.50
L
a,
U= ID:
All types U -0.50
Y
=
U= ID:
U= ID:
Area UA Area UA
Page 2 Subtotal 26 6 26 9
To comply: Page 1 Subtotal 832 51 832 34
1) Proposed Total UA shall not exceed Target Total UA.
2) Proposed Total Area shall equal Target Total Area. Total 858 56 858 43
Component Performance Compliance (UA) UA DOES NOT COMPLY]
O
(N
M
O
`m
ai
0
U)
W
J
Q
U-
O
W
J
W
2
U
U)
N
c c
z z �
� U ~
c
0
U
0
0
0
0
0
0
0
0
0
C.
0
C.
0
0
0
C.
N
L
�
0
0
W
J
W
LLJ
o
0
0
0
X
o
ci
Un
o
or),
o
U)i
O
r�
(5)
e
..
O
Y
U
L
J
d'
CO
N
Ln
(D
N
LO
(o
V
M
N
N
c
�
(fl I--
"It
0
0
0
0
0
0
0
0
0
C.
0
C.
0
0
0
C.
0
0
0
C.
0
D.
0
0
LLJ
o
0
0
0
0
o
ci
Un
o
(n
o
�n
J
d'
CO
N
Ln
(D
N
LO
(o
V
M
N
N
V
N
(n
N
(fl I--
"It
>
U
cfl
cfl
Ga
Ga
U")
Efl
(f3
cA
cA
c13
U
cr�
01)
6q
(A
U),
bq
cA
C�)
G
Y)
Y)
(fl
6
?L
,R3
O'
tu
»J
C�
CL
L
Y
c
VI
1H
LiE
00
r
Y
O
O
cn
C
'M
O_
L
_
o6
E
V
Y
4�
N
.�
•�
Q
cu
Q
Q
,
Y
cz
L
L
L
E
m
3
�
U
i2
f
Y
t4
N
O
O
O
O
O
O
O
M
W
O
N
O
O
U
O
N
Y
Y
O
O
WEW
Y
Y
K
r
O
X
0
O
I.S
I.S
I M
M
.s
O
U
.s
U
d
�I
C:
U �
A �
>
m G a a m.
.�
C4
:
. � .
0
.��
6
? �
\ »�
�
¥�
� 2
. �
\ �
0
■
1
c
/
E
City of Yelm
Community Development Department
Building Division
Phone: (360) 458 -8407
Fax: (360) 458 -3144
Applicant:
Name: CENEX HARVEST STATES
Address: PO BOX 518
AUBURN WA 98071
Property Information:
Site Address: r%nq PWnTnM Pn SF
Assessor Parcel No.: 22719240500 Subdivision:
Contractor Information:
Name: G.O. CONSTRUCTION, LLC
Address: KELLY GRANGER
PO BOX 1536
YELM WA 98597
Contractor License No.: Expires:
Project Information:
Project: NEW COMMERCIAL BUILDING
Description of Work:
Permit No.: 20150136
Issue Date: 3/11/2015
(Work must be completed within 180 days)
Phone: 253 - 833 -7220
Owner: CHS, INC
Lot:
Phone:
0 /00 /0000
Sq. Ft. per floor: First 192 Heat Type (Electric, Gas, Other):
Fees:
Item
MECHANICAL
NEW COMMERCIAL BUILDING
Contractor Fees
SUNSET AIR INC i`r $ 29.50
G.O. CONSTRUCTION, LLC $ 211.16
TOTAL FEES: $ 240.66
Applicant's Affidavit:
I certify that I have read and examined the information contained within the application and know the same
to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of
Yelm regulations including those governing zoning and land subdivision, and in addition, all covenants,
easements and restrictions of record. If applying as a contractor, I further certify that I am currently
registered in the State of Washington.
Signature � Date /0 S
Firm 1.�; �Akl P -) H `r'
OFFICIAL USE ONLY
# Sets of Prints:
Final Inspection:
Date:
By:
6 of y,/,
4Sg,3244
RFC #;
210 �3
RE,c, TE 10/19
PAID By 5108 RM: 001 /2o1s
TRAM:
33 00
201� 6 00 81i"o, Vo
EX PERMIT,
MECH 509 RHOTa�VRD7 sr, 29
R8 cR J
sE
A p �ERE�E; : 29,SpcR D
29.50
CHANGE. 29 sp CHECK
0.00
2:4,5 PM
CITY OF YELM
COMMERCIAL BUILDING PERMIT APPLICATION FORM
Project Address: 699 L AW Parcel #:
Zoning; Current Use: Proposed Use:
New Construction Re -Model / Re -Roof / Tenant Improvement
I I Plumbing I'NVlechanical I Fire Prevent/Suppress /Alarm Other
Project Description /Scope of Work: Q4i ca t A M
Project Value:
C)
Building Area (sq. ft) Parking Garage 1" Floor, `f�`' 2 "d Floor 3 d Floor
Building Height
Are there any environmentally sensitive areas located on the parcel? If yes, a
completed environmental checklist must accompany permit application
BUILDING OWNER /TENANT NAME:
ADDRESS EMAIL
CITY STATE ZIP TELEPHONE
ARCHITECT /ENGINEER LICENSE #
ADDRESS EMAIL
CITY STATE ZIP TELEPHONE
GENERAL CONTRACTOR TELEPHONE
ADDRESS EMAIL
CITY STATE ZIP FAX
CONTRACTOR'S LICENSE # EXP DATE CITY LICENSE #
PLUMBING CONTRACTOR TELEPHONE
ADDRESS EMAIL
CITY STATE ZIP FAX
CONTRACTOR'S LICENSE # EXP DATE CITY LICENSE #
MECHANICAL CONTRACTOR" ez >T c TELEPHO E
ADDRESS ro24 0 Lath) IN o � EMAIL L- C ®
CITY S' ATE�_ZIP FAX S
CONTRACT R'S LICENSE # I EXP DATE CITY LICENSE #
-514n 2-7-0 CWA 2- -3 —IL�e
Copy of City Mitigation documentation (TFC).
I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the
above described property will be in accordance with the laws, rules and regulations of the State of Washington and the
City of Yelyn.
Owner's Agent / Q'ontractor's Agent / Tenant
Date
(Please circle one.)
All permits are non - transferable and'will expire if work authorized by such permit is not begun
within 180 days of issuance, or if work is suspended or abandoned for a period of 180 days
105 Yelm Ave W
Yelm, WA 98597
(360) 458 -3835
(360) 458 -3144 FAX
www.ci.yelm.wa.us
H
Coast Products Inc
Acme Engineering and Manufacturing Corporation
P.O. Box 978, Muskogee, OK 74402
GUARD DISCONNECT (OPTIONAL)
lil�l
II �
ii AIRFLOW
c f uA
r A
n -'ill
Il I
. u
B 2.43
MOTORIZING KIT (OPTIONAL) 62mm
f W Dr 1jJ, I
E .. �
Elevation View Front View
A B C A I D E
37.25 35.16 34.75 37.25 1 29.91 37.25
DIMENSIONS (inches) Rough Opening: 35.25 X 35.25
Print Date: 7/28/2015 6:10:53 PM
Project:CHS Propane
Location:
Customer:Sunset Air, Inc.
Architect:
Engineer:
Contractor:
Submitted by:Pat O'Donnell
DCWBP
Belt Drive Propeller Wall Box Exhaust Fan
Standard Construction Features
2 year Fan /Motor Warranty
5 Year Warranty- Maintenance Free Bearings- Patented -Steel
Shaft -Rated at L -50 life of 200,000 hours
Adjustable Mounting Angles
Back Draft Damper Galy
Corrosion resistant fasteners
Fan -Heavy gauge charcoal baked with UV inhibitors enamel
coated steel frame /orifice base
Galvanized Wall Box
Motor bearings are permanently lubricated
OSHA Approved Motor Side Guard, Galv
Static resistant belts
Steel bladed charcoal baked enamel with UV inhibitors
coated propeller non - overloading design
Variable pitch drives designed for 1.5 Service Factor
Options & Accessories
Motorized Damper & Wiring - -1 Point /NEMA 3R Disconnect -
Actuator 115/1/60
DC30WBP 3/4 Hp 115 /Single Phase /60 Hz/TEAO 1 Speed w/TOL Standard Efficiency Motor RPM: 1750 -- Motorized Damper & Wiring - -1 PoinUNEMA 3R
Disconnect Actuator 115/1/60
PERFORMANCE Altitude = 0 ft Temperature = 68 De rees F Density = 0 075 Ib /ft3
Qty
Model Size
1
DC30WBP
Motor Info. Fan Rating: UL705 CUL705 CSA
Volume SP Power Speed TS OV Weight
(cfm) (in wg) (bhp) (rpm) (fpm) (fpm) (Ibs) HP Volts Phase Hz Encl RPM Sp/Wdg
7200 0.250 0.691 633 4972 1419 273.00 3/4 115 1 60 TEAO 1750 1 SPD
SOUND ( *In free space @ 5 feet/ 1.5 Meters) The sound ratings shown are loudness values in hemispherical
sones at 1.5 m (5ft) in a hemispherical free field calculated per
Static Total AMCA Standard 301. Values are shown for Installation Type A: free
Octave 1 2 3 4 5 6 7 8 LwA dBA* Sones* Eff Eff inlet hemispherical sone levels. The AMCA certified ratings seal
applies to sone ratings only.
Manufacturer reserves the right to change specifications without notice. These are typical drawings for dimensional purpose only and are correct 7/28/201 5 6:1 0:53 PM
within limits for normal installation requirements. They do not necessarily show actual construction
1.00
1.00
0.90
0.90
3
0.80
0.80
� R
_ _ _
0.70
`�. . ^�..._- f- - --•�� _ 0.70
W
0.60
-0.60 0
H
0.50
Sound
DSO Ne
AND
�'
o
0.40
.�'� 0.40 rr
AIR
afAwANYiNCF
0.30
-°
,•�' 0.30
�5
0.20-
Power
85.0
81.5
78.0
76.0
72.9
70.0
67.6
58.9
78.7
67.2
15.8
41.00
61.60
Manufacturer reserves the right to change specifications without notice. These are typical drawings for dimensional purpose only and are correct 7/28/201 5 6:1 0:53 PM
within limits for normal installation requirements. They do not necessarily show actual construction
1.00
1.00
0.90
0.90
3
0.80
0.80
� R
_ _ _
0.70
`�. . ^�..._- f- - --•�� _ 0.70
W
0.60
-0.60 0
H
0.50
0.50 `D
DSO Ne
AND
�'
o
0.40
.�'� 0.40 rr
AIR
afAwANYiNCF
0.30
-°
,•�' 0.30
�5
0.20-
•-
0.20
0.10
-0.10
0.00 " ` "`�;_
0.00
0 2000
4000 6000
8000 10000
Flow (cfm)
- Performance
-• System
• Operating Point
-- Power
•••••• Min. Performance
■ Operating Power
Manufacturer reserves the right to change specifications without notice. These are typical drawings for dimensional purpose only and are correct 7/28/201 5 6:1 0:53 PM
within limits for normal installation requirements. They do not necessarily show actual construction
DC 3v
7
L �
I.ciV ��S