Loading...
20150135 Permit Pkg 03112015City of Yelm Community Development Department Building Division Phone: (360) 458 -8407 Fax: (360) 458 -3144 Applicant: Name: NORTHWEST FAMILY HOMES Address: PO BOX 39 EAST OLYMPIA WA 98540 Property Information: Site Address: 9313 PRAIRIE WIND ST SE Permit No.: 20150135 Issue Date: 3/11/2015 (Work must be completed within 180 days) Phone: 360- 791 -5644 Owner: NORTHWEST FAMILY HOMES Assessor Parcel No.: 64410001800 Subdivision: MCKENZIE MEADOWS Lot: 18 Contractor Information: Name: NORTHWEST FAMILY HOMES Address: PO BOX 39 EAST OLYMPIA WA 98540 Contractor License No.: NORTHFH954BE Expires Phone: 1/05/2017 Project Information: Project: NEW RESIDENTIAL BUILDING Description of Work: LOT 18, PLAN 2978 Sq. Ft. per floor: First 1367 Heat Type (Electric, Gas, Other): GAS Second 1602 Third Garage 638 Basement Fees: Item NEW RESIDENTIAL BUILDING MECHANICAL PLUMBING Contractor Fees NORTHWEST FAMILY HOMES $17,909.87 SUNSET AIR INC $ 78.25 ACME PLUMBING $ 125.00 TOTAL FEES: $ 18,113.12 Applicant's Affidavit: I certify that I have read and examined the information contained within the application and know the same to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of Yelm regulations incl ding those governing zoning and land subdivision, and in addition, all covenants, easements and re i tion of r d. If applying as a contractor, I further certify that I am currently registered in the a of as in ton. Signature Date 3 1/ Firm OFFICIAL USE ONLY # Sets of Prints: Final Inspection: Date: By: Citj of Yelm (36 ) 458 -3244 REC #: 00189166 3/11/2015 OPER: CO TERM: 001 9:52 AM REF #: 14826 PAID BY: TRAN: 33.0000 BUILDING PERMITS 20150135 18,113.12CR NORTHWEST FAMILY HOMES 9313 PRAIRIE WIND ST SE BLD -RES1 17,909.87CR MECH PL 78.25CR 125.000R TRAN: 33.0000 BUILDING PERMITS 20150116 17,919.37CR NORTHWEST FAMILY HOMES 9331 PRAIRIE WIND ST SE BLD -RES1 17,703.12CR MECH PL 91.25CR 125.000R TENDERED: 36,032.49 CHECK APPLIED: 36,032.49- CHANGE: 0.00 ■ Is YELM COMMUNITY SCHOOLS PO BOX 476 YELM NA 98597 Receipt #: 291701 Clerk: Croy Manual #: Terminal: 1 3/6/2015 11:01 AM NNW FAMILY HOMES NNW FAMILY HOMES NORTHWEST, FAMILY HOMES 7426 MANZANITA DR NW OLYMPIA, WA 98502 Qty Item _ Price 1 CPF MITIGATION 3015.00 MITIGATION 08 -007 / LOT 15 / 9331 PRAIRIE WIND;YELM 1 CPF MITIGATION 3015.00 MITIGATION 08 - -007 / LOT 18 / 9313 PRAIRIE WIND;YELM Subtotal 6030.00 Tax 0.00 Total 6730.00 Debit /Credit 6030.00 Change Due 0.00 THANK YOU CITY OF YELM RESIDENTIAL. BUILDING PERMIT APPLICATION FORM Project Address - C/ 1 l' res ire ( *) re Parcel #:. -IOU G G10 /0 d 3ubdivisionjlylCKAti2,r ii/ieGt a.,, Lot #: Plan #: � �_� � _ Zoning:_ _ XNew Construction I I Re -Model / Re -Roof / Addition 1, Home uccupation Sign 1 Plumbing I Mechanical Mobile / Manufactured Home Placement I" Other / Project Description /Scope of Work: ( yt r I iA Project Value: Building Area (sq. ft) 16t Floor �? 7 2 °d Floor _ �_ Garage 6 _ Deck Basement Carport Patio 4",_t1(, # Bedrooms r # Bathrooms � �z Heating: AS THER or ELECTRIC (Circle One) Are there any environmentally sensitive areas located on the parcel? If yes, a completed environmental checklist must accompany permit application. Copy of mitigation agreement with Yelm Community ools, if applicable. I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above described property will be In accordance with the laws, rules and re n ulations of the State of Washington City of Yelm. s gtoa and the Applicant'�sS i ate Owner / Contractor / Owner's Agent / Contractor's Agent (Please circle one.) All permits are non - transferable and will expire if work authorized by such permit is not begun within 980 days of issuance, or if work is suspended or abandoned for a period of 180 days 105 elm Avenue West — -- — — -- — Yelm, WA 98597 (f0) 458 -3835 Imm-ei.yelr ava.us (360) 458f -3X44 FA<i' ► , FEB 2 6 2015 N r r I F 2o c -. r W61 -*I J 1 yI L�ddc(1F0 Pfi'r�ti KMJ z� ? y 6eavvv�,� v A F(oarEL. i � X 441 Uo 0 1 i)�' I a I 11 i ' L, 1 1 '71 zi C,v: � CDUC1tft fyv ai ✓1� � I tH Ore . x0 ; - - - ,fi g + City of helm, CDD s rr:TF pur vE l = rnk� vv,-� � ' w Approved Pac+�rr. 6� s 3 % ,U Coble 'i+hon{ � � ��, r � I t S .� �' `3t ! - 10'444 1 S �Xwdt�c fv �+ w _cu90 r 6 .u0 !; Gw12 WAT1;R Mmg ocgX 2' MINIMUM SETBACK S +�ec� trot BETWEEN SIDEWALKS, DRIVEWAYS, EASEMENTS, AND STEP TANK. Wrp� SU 134((�0 1NG- h2eY� r z 19S Sca . iyt. - 77 1,, 11A4 0690 l AIZEJ� Z`).S 3 f FEB 2 6 2015 �L City of Yelm 105 Yelm Avenue West Yelm, WA 98597 The City of Yelm implements Section R401.3 of the International Residential Code in soils identified as fine outwash or till as follows: The finished grade of the under floor shall be the same as the outside finished grade and shall include 6 inches of pea gravel under the required vapor barrior; or A foundation drainage system shall be provided around the perimeter of the building. The foundation drainage system shall be perforated or open - jointed approved drain tile or pip, not less than 3 inches in diameter. Foundation drains shall be laid in drain rock or other approved porous material with not less than 4 inches surrounding the pipe and wrapped with filter fabric. The foundation drainage system shall discharge to an approved surface location which will not impact any adjacent property or a drywell sized according to Section R405.1 IRC. The City of Yelm implements Section 1101QY of the Uniform Plumbing Code as follows: Roof drains shall be installed around the entire foundation wall perimeter in a loop. A cleanout shall be located in line within 1 foot of the foundation wall and the approved drainage system. Roof drainage piping shall be tested pursuant to Section 1109 of the ' 4 Uniform Plumbing Code. Roof drains shall discharge to an approved surface location which will not impact any adjacent property or to a drywell sized according to Section 1101.3 UPC. ,. ,,... � "-&& (360) 458 -3335 (360) 458 -3144 FAX wwwxLyelm.wa.us Prescriptive Energy Code Compliance for All Climate Zones in Washington Project Information a Contact Information c 2, C 14fee ew 6 e e- ✓i y Vd4 ltwe. j F4,it/1 h4el 7 -SL This project will use the requirements of the Prescriptive Path below and incorporate the the minimum values listed. In addition, based on the size of the structure, the appropriate number of additional credits are checked as chosen by the permit applicant. Authorized Representative IK4 Date All Climate Zones Efficient Building Envelope 1 a R- Valuea U- Factor a Fenestration U- Facto►' n/a 0.30 Skylight U- Factor n/a 0.50 Glazed Fenestration SHGCb•e n/a n/a Ceiling 49' 0.026 Wood Frame Wall"" 21 int 0.056 Mass Wall R- Value' 21121" 0.056 Floor 309 0.029 Below Grade Wall°,k 10/15/21 int +TB 0.042 ISlab R- Value & Depth 10, 2 ft n/a *Table R402.1.1 and Table R402.1_3 Footnotes included on Page 2. Each dwelling unit in one and two- family dwellings and townhouses, as defined in Section 101.2 of the International Residential Code shall comply with sufficient options from Table R406.2 so as to achieve the following minimum number of credits: ❑1. Small Dwelling Unit: 0.5 points Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration area. Additions to existing building that are less than 750 square feet of heated floor area. (. Medium Dwelling Unit: 1.5 points i— All dwelling units that are not included in #1 or #3, including additions over 750 square feet. ❑3. Large Dwelling Unit: 2.5 points Dwelling units exceeding 5000 square feet of conditioned floor area. Table R406.2 Summary Option Description Credit(s) 1 a Efficient Building Envelope 1 a 0.5 1 b Efficient Building Envelope 1 b 1.0 1c Efficient Building Envelope 1c 2.0 2a Air Leakage Control and Efficient Ventilation 2a 0.5 2b Air Leakage Control and Efficient Ventilation 2b 1.0 2c Air Leakage Control and Efficient Ventilation 2c 1.5 3a High Efficiency HVAC 3a 0.5 3b High Efficiency HVAC 3b 1.0 3c High Efficiency HVAC 3c 2.0 3d High Efficiency HVAC 3d 1.0 4 High Efficiency HVAC Distribution System 1.0 5a Efficient Water Heating 0.5 5b Efficient Water Heating 1.5 6, Renewable Electric Energy 0.5 Total Credits *Please refer to. Table R406.2 for complete option descriptions httr)://www.energy.wsu.edu/Documents/2012%2ORes`/`2OEnergv.pdf IM *1200 kwh ,s FEB 2 6 20 55 [fill Simple Heating System Size: Washington 5tate This heating system sizing calculator is based on the Prescriptive Requirements of the 2012 Washington State Energy Code (WSEC} and ACCA Manuals J and S This calculator will calculate heating loads only, ACCA procedures for sizing cooling systems should be used to determine coolino loads. The glazing (window) and door portion of this calculator assumes the installed glazing and door products have an area weighted average U- factor of 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC. Please fill out all of the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please call the WSU Energy Extension Program at (360) 956 -2042 for assistance. Project Information —7 C " ! C G Uwe Ron Deering Lot ) (' 791 -5644 Heating System Type: O All other systems O Heat Pump To see detailed instructions for each section, place your cursor on the word "Instructions ". Design Temperature ..___ --- .__.___ _ - -- - -- -- Instructions - Design Temperature Difference A Olympia, AP. AT= Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) Average Ceiling Height Instructions Average Ceiling Height (ft) Glazing and Doors Instructions Skylights Instructions Insulation X. Area = Attic Conditioned Volume Instructions R-49 X Area U- Factor X Area = Single Rafter or Joist Vaulted Ceilings Z t✓ Instructions c� R -Value X Area = 0.50 X Area Above Grade Walls (_see Figure 1) I i '( (; S Instructions R -21 Intermediate -• Floors L� F- Factor X Length Instructions I R30 F- Factor X Length} Below Grade Walls (see Figural) �J Instructions R -value Slab Below Grade (see F)gure 1) Instructions Selectcondiuonlnp Slab on Grade (see Figure 1) Instructions :. I Select R -Value Location of Ducts Instructions Space unconditioned �'s...vcY. -� ssaa.�aiauu.<r< � ass...macauax:s.a ml Figure 1 _ Above Grade U- Factor X. Area = 0.026 Conditioned Volume U- Factor X Area U- Factor X Area = 0.30 Z t✓ U- Factor X Area = 0.50 X Area U- Factor X. Area = 0.026 U- Factor X Area No selection C� U- Factor X Area 0.056 S TCT U- Factor X Area 0.029 I i '( (; S U- Factor X Area No selection L� F- Factor X Length No selection F- Factor X Length} No selection �J Sum of UA Duct Leakage Coefficient 1.10 F'�c3 UA C) UA UA 3� t� UA UA t2 JZ UA `'fit % Li UA UA UA 3(c o el, Envelope Heat Load I% J 7 Btu / Hour Sum of LAX AT Air Leakage Heat Load ' J (` Btu I Hour Volume X 0.6 X eT X .018 Building Design Heat Load Btu / Hour Air Leakage + Envelope Heat Loss 7 Building and Duct Heat Load ? } " Btu / Hour Ducts in unconditioned space: Sum or Building Heat Loss X 1.10 Ducts in conditioned space: Sum of Building Heat Loss X f U / Maximum Heat Equipment Output ' �( _` ` Btu / Hour Building and Duet Heat Loss X 1.40 for Forced Air Furnace Building and Duct Heat Loss X 1.25 for Heat Pump (07/01/13) 0 Window, Skylight and Door Schedule Project Information Contact tnf venation 3 t:,-4e n -7-1 e 04 eed o w aq- (�� e Ivev-ftwell' Fkim,L, tf-okAej -7 el I -SI It Y Width. Height- Arkh Reif. 'Ll-factor Qt. Feet .7 Feet Inch Area UA Exempt Swinging Door (24 sq. ft.- max:) Exempt Glazed Fenestration (15 sq. ft max.) i 3 OF i 3.2--' Z . .7 C; Vertical Fenestration (Windows and doors) Component Width Height Description Inch Inch Ref. U-factor Qt. Feet Feet Area HA 19 "0 V, I "-,J e- c ,-2_✓ _Tee-, our 6o6t t4 MMEME C__ - i+ V/ o F r-7 e- - t 3c% LO 4 1 t -, 3 di,,, ,t 1 &-ve 9 V ( I 111 + L64_ v S 0 =ME %2 Cloje-t H MMEME 0.0 Lf 4v it 3 L11 V_ 0.00 30 VA C, .1- 9 f, K 0 LA U Re-ft 14 V 0.001 0.0 0.00 0.0 - 30, 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.01 0.00 MMEMM MMEME MENEEM MEMME EMIM IMEMINE INEMEM MMEMM ME ,-2_✓ MEN MMEME MMMMM ©©E®® MMUMM .2S_ MRIMMM S 0 =ME MMEME 0.0 MENEME 0.0 0.00 0.0 0.00 MMEM01 0.00 0.0 0.00 0.0 0.001 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.01 0.00 MMEMM MMEME MENEEM MEMME EMIM IMEMINE INEMEM MEMEM NEEMEM MEMEM --E-E NMNEMO MINE =MEMO MEMEM =MEMO NEEM INNINNIN MEINME IMEMEN MMNME1 =ME= MMEMBE 2­0 ME ,-2_✓ MEN MMMMM MMUMM .2S_ MRIMMM S 0 =ME 0.0 MENEME 0.0 0.00 0.0 0.00 MMEM01 0.00 0.0 0.00 0.0 0.001 0.0 0.00 0.0 0.00 2­0 ,-2_✓ .2S_ S 0 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.001 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.01 0.00 ?1? L -7 21 YHOMPSON E= M C— I M E S R I N 0 Sheet: con -page or� Jf a .PPrOved W, A "� ' m 1447 rpw NAL .10-08 W-28 IN � a" 0,1� M"�m VMA APPROVED rp,-iv 3 FE -- 2 6 c WAI- r-Ift WTA" M wecs. Fr% $a K OuTf (age MV U I &I W1 CAP fopla Im THOMPSON E E R I N G 360-S18 E3079 Fax: 350-350-0803 Job — II-)e1v -OA� Date'. By. F Sheet' Page 2- W 4-2.5 5LOT U14LL Si4EA1 -� 4 PLACE BEFORE MKS - LOUR l4k, t Lese- WA Z-). e- (L-�to c. 34471 -2X& SLK4L-5TUX T40 HATCM F400r- SL PLACE AFTER 14-2-5, 'CLIPS (2) ROM 16 d'ro .0 a or. LOW ROOF/W-EAR WALL -DETAIL City of Yelm Community Development Department Residential Certificate of Occupancy Building Address 9313 PRAIRIE WIND ST SE Owner Name NORTHWEST FAMILY HOMES Owner Address PO BOX 39 EAST OLYMPIA WA 98540 Building Permit Number 20150135 Remarks: LOT 18, PLAN 2978 Areas Inspected Special Conditions Building Official ALL CODE REQUIRED & CARLSON Plan Number 2978 Date: August 4, 2015 This structure is in compliance with the International Residential Code (Chapter 51 -51 WAC) as adopted by the Washington State Building Code Council pursuant to Chapters 19.27 and 70.92 RCW, effective July 1, 2004