20150144 Permit Pkg 04012015City of Yelm Community Development Department Building Division Phone: (360) 458 -8407 Fax: (360) 458 -3144 Applicant: Name: RAINIER GENERAL DEVELOPMENT Address: P.O. BOX 627 RAINIER WA 98576 Property Information: Site Address: 14933 91 ST AVE SE Assessor Parcel No.: 33860002900 Contractor Information: Name: RAINIER GENERAL DEVELOPMENT Address: DOUG BLOOM P.O. BOX 627 RAINIER WA 98576 Permit No.: 20150144 Issue Date: 4101/2015 (Work must be completed within 180 days) Phone: 360- 400 -0740 Owner: RAINIER GENERAL DEVELOPMENT Subdivision: BELLA HOUSA VILLAGE Lot: 29 Contractor License No.: RAINIGD115QL Expires Phone: 360- 400 -0740 1/01/2011 Project Information: Project: NEW RESIDENTIAL BUILDING Description of Work: LOT 29, PLAN 2824H Sq. Ft. per floor: First 751 Heat Type (Electric, Gas, Other): Second Third Garage Basement Fees: Item NEW RESIDENTIAL BUILDING MECHANICAL PLUMBING 1104 393 Contractor RAINIER GENERAL DEVELOPMENT SOUND HEATING & AC PRIDE CONSTRUCTION TOTAL FEES: Applicant's Affidavit: I certify that I have read and examined the information contained within the application and know the same to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of Yelm regulations including those governing zoning and land subdivision, and in addition, all covenants, easements and restrictions of record. If applyJng13s a contractor, I further certify that I am currently registered in the State o a tones Signature Date Firm Fees $17,481.05 $ 49.25 $ 104.00 $ 17,634.30 OFFICIAL USE ONLY # Sets of Prints: Final Inspection: Date. By: of Yolm (36N 458 -3244 REC #: 00190796 4/01/2015 3 :00 PM OPER: CO TERM: 001 REF #: 48931 PAID BY: TRAN: 33.0000 BUILDING PERMITS 20150144 17,634.30CR RAINIER GENERAL DEVELOPMENT 14933 91ST AVE SE BLD -RES1 17,481.05CR MECH 49.25CR PL 104.000R TENDERED: 17,634.30 CHECK APPLIED: 17,634.30- City of Yolm (36 ) 458 -3244 CHANGE: 0.00 REC #: 00190797 4/01/2015 3 :01 PM OPER: CO TERM: 001 REF #: 48930 PAID BY: TRAN: 33.0000 BUILDING PERMITS 20150143 17,278.08CR RAINIER GENERAL DEVELOPMENT 14939 91ST AVE SE BLD -RES1 17,061.33CR MECH 84.75CR PL 132.000R TENDERED: 17,278.08 CHECK APPLIED: 17,278.08- CHANGE: 0.00 YELM COMMUNITY SCHOOLS PO BOX 476 YELM WA 98597 Receipt #: 295638 Clerk: Croy Manual #: Terminal: 1 4/1/2015 2:30 PM NRAINIER DEVEL. NRAINIER DEVEL. RAINIER GENERAL , DEVELOPMENT, INC. PO BOX 627 RAINIER, WA 98576 Qty Item 1 CPF MITIGATION MITIGATION 07 -016 / LOT 28 / 14939 91ST AVE SE;YELM Price 3015.00 1 CPF MITIGATION 3015.00 MITIGATION 07- 016 /LOT 29/14933 91ST AVE SE;YELM Subtotal 6030.00 Tax 0.00 Total 6030.00 Debit /Credit 6030.00 Change Due 0.00 THANK YOU vs v 01 CITY OF YELM RESIDENTIAL BUILDING PERMIT APPLICATION FORM Project Address: 14933 91 ST AVE SE Parcel #. 33860002900 Subdivision: BELLA HOUSA Lot #: 29 Plan #: 2824H Zonin g' R6 X New Construction Re -Model / Re -Roof / Addition Home Occupation Sign Plumbing Mechanical Mobile / Manufactured Home Placement Other Project Description /Scope of Work: CONSTRUCT 1855sgft SFR Project Value: $190,000 Building Area (sq. ft) 1 sc Floor 751 2nd Floor 1104 3`d Floor Garage -2 car 393 3 car Covered Patio Covered Porch 44 Patio 120 Deck # Bedrooms 4 # Bathrooms 2.5 Heating: GAS /OTHER or ELECTRIC (Circle One) Are there any environmentally sensitive areas located on the parcel? NO If yes, a completed environmental checklist must accompany permit application. BUILDING OWNER NAME: RAINIER GENERAL DEVELOPMENT, INC ADDRESS PO BOX 627 EMAIL rgdinc @ywave.com CITY RAINIER STATE WA ZIP 98576 TELEPHONE 360 -400 -0740 ARCHITECT /ENGINEER LICENSE # ADDRESS EMAIL CITY STATE ZIP TELEPHONE GENERAL CONTRACTOR RGD, INC TELEPHONE 360 - 400 -0740 ADDRESS PO BOX 627 EMAIL rgdinc @ywave.com CITY RAINIER STATE WA ZIP 98576 FAX 360- 400 -0828 CONTRACTOR'S LICENSE # RAINIGD115QL EXP DATE2016CITY LICENSE # 10627 PLUMBING CONTRACTOR PRIDE CONSTRUCTION TELEPHONE 360 -446 -4027 ADDRESS PO BOX 209 EMAIL pride—construction@yahoo.com CITY RAINIER STATE WA ZIP 98576 FAX CONTRACTOR'S LICENSE # PRIDECB941P6 EXP DATE2016CITY LICENSE # MECHANICAL CONTRACTOR SOUND HEATING TELEPHONE 253- 875 -3350 ADDRESS 5526 184TH ST SE SUITE A EMAIL Tammy @soundheating.com CITY PUYALLUP STATE WA ZIP98373 FAX 253- 875 -0285 CONTRACTOR'S LICENSE #SOUNDHA066BM EXP DATE2016CITY LICENSE # Copy of mitigation agreement with Yelm Community Schools, if applicable. I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above described property will be in accordance with the laws, rules and regulations of the State of Washington and the City of Yelm. Applicant's Signature Date Owner / Contractor / Owner's Agent / Contractor's Agent (Please circle one.) All permits are non - transferable and will expire if work authorized by such permit is not begun within 180 days of issuance, or if work is suspended or abandoned for a period of 180 days t�� I MAR 10 2015 105 Pelm Avenue West (360) 458 -3835 Yelm, WA 98597 (360) 458 -3144 FAX www.ci.yelm.wa.us VILLAGE AT OAK PRAIRIE LOT 29 r7TFIL-- ity of Yelm, CDD Approved s is 2' MINIMUM SETBACK BETWEEN SIDEWALKS, DRIVEWAYS, EASEMENTS, AND STEP TANK. Notes: 1) FRONT PORCH FOUNDATION AND STEP TANK LOCATION SHALL BE STAKED OUR FOR SET BACK INPSECTION. 2) STEP TANKS ARE TO BE LOCATED 2' MINMUM FROM SIDEWALK, DRIVEWAY AND EASEMENTS. 5' MINIMUM FROM FOUNDATION AND PROPERTY LINES. 3) STEP TANK IN VIOLATION OF THE REQUIRED 5' MINIMUM SETBACK TO FOUNDATION SHALL BE BACK FILLED WITH CDF. 4) CONNECT PVC ROOF DRAINS TO DRYWELL AND TEST DRAINS. SCALE: 1 " =20 FEET 0 10 20 40 91ST AVE Driveway Qonstruction e 5'+ Sidewalk 18 Porch 2824 —H 30 1902sf M n u') 5.0 40 10'+ 25.0 5'x15' Drywell 52.00 SE Water 37.9 ( Power I Gas n N rn 7.0 N 4,w o w co 0 m S 0177'13" W 51.05 m o Ch .� N to w H \ N ® \ O NI C S I 0P I CA ® I NI do ~ Co ® I to rn 51.72— 52.00— 52.00 a00 N 01'39148" E 155.22 i r I � 0 0 p MOUNTAIN VIEW ROAD SE 7.00 92.58 r cn T V co o O N 0 I to N 0177'13" E 100.05 54•eg 45.36 CD Z �® ' rn � X \ 00 C/-) °' to v m xxx z N z v v W C/) OV _ �1 z z z m N O m�CD r-m r-H r-m n S 0177'13" W 57.83 y ❑❑ ❑ ® H .p "g O N � V y O CNO N S 0177'13" W 92.74 N 4,w o w co 0 m S 0177'13" W 51.05 m o Ch .� N to w H \ N ® \ O NI C S I 0P I CA ® I NI do ~ Co ® I to rn 51.72— 52.00— 52.00 a00 N 01'39148" E 155.22 i r I � 0 0 p MOUNTAIN VIEW ROAD SE Of T�1► o° YEL City of Yelm 105 Yelm Avenue West Yelm, 'WA 08597 The City of Yelm implements Section R401.3 of the International Residential Code in soils identified as fine outwash or till as follows: The finished grade of the under floor shall be the same as the outside finished grade and shall include 6 inches of pea gravel under the required vapor barrior; or A foundation drainage system shall be provided around the perimeter of the building. The foundation drainage system shall be perforated or open- jointed approved drain tile or pip, not less than 3 inches in diameter. Foundation drains shall be laid in drain rock or other approved porous material with not less than 4 inches surrounding the pipe and wrapped with filter fabric. The foundation drainage system shall discharge to an approved surface location which will not impact any adjacent property or a drywell sized according to Section R405.1 IRC. The City of Yelm implements Section 11OLY of the Uniform Plumbing Code as follows: Roof drains shall be installed around the entire foundation wall perimeter in a loop. A cleanout shall be located in line within 1 foot of the foundation wall and the approved drainage system. Roof drainage piping shall be tested pursuant to Section 1109 of the Uniform Plumbing Code. Roof drains shall discharge to an approved surface location which will not impact any adjacent property or to a drywell sized according to Section 1101.3 UPC. (360) 458 -3835 (360) 458 -3144 FAX wwwxLyelm.wa.us Simple Heating System Size: Washington State This heatinq system sizing calculator is based on the Prescriptive Requirements of the 2012 Washington State Energy Code (WSEC) and ACCA Manuals J and S. This calculator will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. The glazing (window) and door portion of this calculator assumes the installed glazing and door products have an area weighted average U- factor of 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC. Please fill out all of the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please call the WSU Energy Extension Program at (360) 956 -2042 for assistance. Project Information Contact Information Village at Oak Prairie- Lot 29 Rainier General Development Yelm, WA 360- 400-0740 Heating Svstem Type: O All Other systems O Heat Pump To see detailed instructions for each section, place your cursor on the word 'Instructions ". Design Temperature I I Instructions - – __ —_"' - --- ' u - "- — -- -- Design Temperature Difference (4T) umwater T �� � t j° AT= Indoor (70 degrees) -Outdoor Design Temp Area of Buildinq 14,359 Btu / Hour Sum of UA X AT Conditioned Floor Area Air Leakage Heat Load 9,662 Btu/ Hour VolumeX 0.6XATX.018 Instructions Conditioned Floor Area (sq ft) 1,855 24,022 Btu / Hour Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) Btu /Hour 9.1 16,881 Glazing and Doors U- Factor X Area = UA Instructions Building and Duct Heat Loss X 1.40 for Forced Air Furnace Building and Duct Heat Loss X 1.25 for Heat Pump 0.30 273 81.90 Skylights U- Factor X Area = UA Instructions 0.50 - -- Insulation Attic U- Factor X Area = UA Instructions R -3S Advanced ��� =x 0.026 751 19.53 Single Rafter or Joist Vaulted Ceilings U- Factor X Area UA Instructions -- m __: Select R -Value v_. � No selection 0 - Above Grade Walls (see Figure 1) U- Factor X Area UA Instructions �. R -21 Intermediate • 0.056 2,199 123.13 Floors U- Factor X Area UA Instructions R -38 µ" " " F ' 0.025 1,855 46.38 Below Grade Walls (see Figure 1) U- Factor X Area UA Instructions SeI�R- value ��_ - i No selection r - -- Slab Below Grade (see Figure 1) F- Factor X Length UA Instructions r` " ""` "`�`'"' "- "` -""�` `"" Select - No selection - -- 'j conditioning Slab on Grade (see Figure 1) F- Factor X Length gth UA instructions ; Selea R -Value � � i ' %�- No selection - -- Location of Ducts Instructions Duct Leakage Coefficient Unconditioned Space 1.10 Sum of UA 270.93 Figure 1. Above Grade 53 Envelope Heat Load 14,359 Btu / Hour Sum of UA X AT Air Leakage Heat Load 9,662 Btu/ Hour VolumeX 0.6XATX.018 Building Design Heat Load 24,022 Btu / Hour Air Leakage + Envelope Heat Loss Building and Duct Heat Load 26,424 Btu /Hour Ducts in unconditioned space: Sum of Building Heat Loss X 1.10 Ducts in conditioned space: Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 36,993 Btu / Hour Building and Duct Heat Loss X 1.40 for Forced Air Furnace Building and Duct Heat Loss X 1.25 for Heat Pump (07/01/13) Prescriptive Energy Code Compliance for All Climate Zones in Washington Project Information Contact Information Village at Oak Prairie- Lot 29 Rainier General Development Yelm, WA 360 -400 -0740 This project will use the requirements of the Prescriptive Path below and incorporate the the minimum values listed. In addition, based on the size of the structure, the appropriate number of additional credits are checked as chosen by the permit applicant. Authorized RepresentatiVe ?/ Date t All imate Zones Efficient Building Envelope 1 a R- Values U- Factor a Fenestration U- Factor b n/a 0.30 Skylight U- Factor n/a 0.50 Glazed Fenestration SHGCb a n/a n/a Ceiling 4Y 0.026 Wood Frame Wall 9,k l 21 int 0.056 Mass Wall R- Value' 21/21h 0.056 Floor 309 0.029 Below Grade Wallc,k 10/15/21 int + TB 0.042 Slab' R -Value & Depth 10, 2 ft n/a *Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2. Each dwelling unit in one and two - family dwellings and townhouses, as defined in Section 101.2 of the International Residential Code shall comply with sufficient options from Table R406.2 so as to achieve the following minimum number of credits: ❑1. Small Dwelling Unit: 0.5 points Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration area. Additions to existing building that are less than 750 square feet of heated floor area. F�12. Medium Dwelling Unit: 1.5 points All dwelling units that are not included in #1 or #3, including additions over 750 square feet. ❑3. Large Dwelling Unit: 2.5 points Dwelling units exceeding 5000 square feet of conditioned floor area. ❑4. Dwelling unit other than one and two- family dwellings and townhouses: Exempt As defined in Section 101.2 of the International Residential Code Table R406.2 Summary Option Description Credit(s) la Efficient Building Envelope 1 a 0.5 lb Efficient Building Envelope lb 1.0 1C Efficient Building Envelope 1c 2.0 2a Air Leakage Control and Efficient Ventilation 2a 0.5 2b Air Leakage Control and Efficient Ventilation 2b 1.0 2c Air Leakage Control and Efficient Ventilation 2c 1.5 3a High Efficiency HVAC 3a 0.5 3b High Efficiency HVAC 3b 1.0 3c High Efficiency HVAC 3c 2.0 3d High Efficiency HVAC 3d 1.0 4 High Efficiency HVAC Distribution System 1.0 5a Efficient Water Heating 0.5 5b Efficient Water Heating 1.5 6 Renewable Electric Energy 0.5 �I I� '0 1-1 *1200 kwh Total Credits *Please refer to Table R406.2 for complete option descriptions http: / /www.energy.wsu.edu /Documents /Table 406 2 Energy Credits 2012 WSEC.pdf 0.5 0.5 0.5 0.0 1.50 Table R402.1.1 Footnotes For SI: 1 foot .= 304.8 mm, ci .= continuous insulation, int .= intermediate framing. a R- values are minimums. U- factors and SHGC are maximums. When insulation is installed in a cavity which is less than the label or design thickness of the insulation, the compressed R -value of the insulation from Appendix Table A101.4 shall not be less than the R -value specified in the table. b The fenestration U- factor column excludes skylights. The SHGC column applies to all glazed fenestration. Exception: Skylights may be excluded from glazed fenestration SHGC requirements in Climate Zones 1 through 3 where the SHGC for such skylights does not exceed 0.30. "10/15/21. +TB" means R -10 continuous insulation on the exterior of the wall, or R -15 on the continuous insulation on the interior of the wall, or R -21 cavity insulation plus a thermal break between the slab and the basement wall at the interior of the basement wall. "10/15/21. +TB" shall be permitted to be met with R -13 cavity insulation on the interior of the basement wall plus R -5 continuous insulation on the interior or exterior of the wall. "10/13" means R -10 continuous insulation on the interior or exterior of the home or R -13 d R -10 continuous insulation is required under heated slab on grade floors. See R402.2.9.1. e There are no SHGC requirements in the Marine Zone. f Basement wall insulation is not required in warm -humid locations as defined by Figure R301.1 and Table R30 8 Reserved. h First value is cavity insulation, second is continuous insulation or insulated siding, so "13. +5" means R -13 cav ' The second R -value applies when more than half the insulation is on the interior of the mass wall. For single rafter- or joist-vaulted ceilings, the insulation may be reduced to R -38. k Int. (intermediate framing) denotes standard framing 16 inches on center with headers insulated with a mini Log and solid timber walls with a minimum average thickness of 3.5 inches are exempt from this insulation rE Footnote la Nonfenestration U- factors shall be obtained from measurement, calculation or an approved source or as sp W V q0 V ti O � It NM W N N E Z W U) J Q (0 LO i WZ m Q Z W (D ti CD Q U) rn X ICT W -1 0 co co Z�mZ Lo 0 a N cn CD (D E Q m D) Z c L- La W C m O Ch cn N Q C E 7 Z E N c .5 m 2 N 00 N Z g N H O J Y ca N W W O J J Q m U N Q cn c cn m (D Q C O C O U cu •U N Q U) 0 N N ai ca Z O U) J U L, T i r- LO .� AL W , a M (6 i Q 0 O U N O : U O >+ U a� � -a a) L) �C;)� c m U o a) � � N L vJ C) O a L N N cn N ca 0 a) U n � 0 o Ch m U cn M City of Yelm Community Development Department Building Division Phone: (360) 458 -8407 Fax: (360) 458 -3144 Applicant: Name: RAINIER GENERAL DEVELOPMENT Address: P.O. BOX 627 RAINIER WA 98576 Property Information: Site Address: 14933 91ST AVE SE Assessor Parcel No.: 33860002900 20.00 Project Information: $ Project: NEW RESIDENTIAL BUILDING Description of Work: LOT 29, PLAN 2824H Sq. Ft. per floor: First 751 19.00 Second 1104 $ Third PAYMENTS MADE: Garage 393 49.25 Basement Fees: Item MECHANICAL PERMIT FURNACE 100,000 BTU EXHAUST FANS WHOLE HOUSE FAN /MISCELLANEOUS Citt of Nm (36) 458 -3244 REC #: 00205534 8/31/2015 1:09 PM OPER: CO TERM: 001 REF #: 49477 PAID BY: TRAN: 33.0000 BUILDING PERMITS 20150144 35.50CR RAINIER GENERAL DEVELOPMENT 14933 91ST AVE SE MECH 35.50CR TENDERED: 35.50 CHECK APPLIED: 35.50 - CHANGE: 0.00 Permit No.: 20150144 Fee Calculation Worksheet Phone: 360- 400 -0740 Owner: RAINIER GENERAL DEVELOPMENT Subdivision: BELLA HOUSA VILLAGE Lot: 29 Heat Type (Electric, Gas, Other): Units Fees 1 $ 20.00 1 $ 13.25 5 $ 32.50 2 $ 19.00 TOTAL FEES: $ 84.75 PAYMENTS MADE: $- 49.25 BALANCE DUE: $ 35.50