Loading...
20150172 Permit Pkg 04242015City of Yelm Community Development Department Building Division Phone: (360) 458 -8407 Fax: (360) 458 -3144 Applicant: Name: SOUNDBUILT NW LLC Address: PO BOX 73790 PUYALLUP WA 98373 Property Information: Site Address: 14434 99TH WAY SE Assessor Parcel No.: 78640116400 Contractor Information: Name: SOUNDBUILT NW LLC Address: PO BOX 73790 PUYALLUP WA 98373 Contractor License No.: Project Information: Project: NEW RESIDENTIAL BUILDING Description of Work: LOT 164, PLAN 1741A Sq. Ft. per floor: First 1741 Second Third Garage 414 Basement Fees: Item NEW RESIDENTIAL BUILDING MECHANICAL PLUMBING Subdivision Permit No.: 20150172 Issue Date: 4124/2015 (Work must be completed within 180 days) Phone: 253 - 848 -0820 Owner: SOUNDBUILT NW LLC TAHOMA TERRA Lot: 164 Phone: Expires: 0 /00 /0000 Heat Type (Electric, Gas, Other): GAS Contractor Fees SOUNDBUILT NW LLC $17,090.69 SOUND HEATING & AC $ 71.75 RAINIER VIEW ROOTER, LLC $ 104.00 TOTAL FEES: $ 17,266.44 Applicant's Affidavit: I certify that I have read and examined the information contained within the application and know the same to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of Yelm regulations including those governing zoning and land subdivision, and in addition, all covenants, easements and restrictions of record. If applying as a contractor, I further certify that I am currently registered in the State of Washin lton. Signature j! Date r Firm OFFICIAL USE ONLY # Sets of Prints: Final Inspection: Date: By: City of Yolm (36 ) 458 -3244 REC #: 00193411 4/24/2015 2:18 PM OPER: CO TERM: 001 REF #: 4649 PAID BY: TRAN: 33.0000 BUILDING PERMITS 20150172 17,266.44CR SOUNDBUILT NW LLC 14434 99TH WAY SE BLD -RES1 17,090.69CR MECH 71.75CR PL 104.000R TENDERED: 17,266.44 CHECK APPLIED: 17,266.44 - CHANGE: 0.00 YELM COMMUNITY SCHOOLS PO BOX 476 YELM WA 98597 Receipt #: 299453 Clerk: Croy Manual #: Terminal: 1 4/24/2015 2:08 PM NSOUNDBUILT NSOUNDBUILT SOUND BUILT NW LLC, HOMES PO BOX 73790 PUYALLUP, WA 98373 -0790 Qty Item Price 1 CPF MITIGATION 3015.00 MITIGATION 05- 027 /LOT 40/10047 JENSEN DR SE;YELM 1 CPF MITIGATION 3015.00 MITIGATION 05- 027 /LOT 164/ 14434 99TH WAY SE;YELM Subtotal 6030.00 Tax 0.00 Total 6030.00 Check 6030.00 4648 Change Due 0.00 THANK YOU CITY OF TEL 5� `i "M RESIDENTIAL BUILDING PERMIT APPLICATION FORM Project Address: / N" 3 y �� Gv ,4 -, L Parcel SubdMsion: :L4 " Lot* I k `/ _ Plan Zoning: New Construction D Re.Model / Re -Roof / Addition r Home Occupation Sign D Plumbing D Mechanical D Mobile / Manufactured Home / -Placement D,, /Other project DescriptioNScope of Work: pry value: 2G Building Area (sq. ft) 1" Fbor� 2n° Fbar__,____ �� � Deck Basement Carport Patio_�� # Bedrooms_ # Bathrooms Heating: S/OTH or ELECTRIC (Circle One) Are there any environment3HY sensitive areas located On the Parcel ?__ K yes, a completed environmental cheddist must accompany Permit application. Copy of mitigation agreement with Yelm Community Schools, if applicable. above dowood Property wbi be accordame wkh Ow laws, � rpulations of ew sLaa occupancy and the City of Yslm. GJ� Y/ 7 s Dab a / a Agent (Plsass clncis one.) Owner / Contractor sir's � A!! psrenlibs an non bee and will lxplre if work authorized by such penmit is not be gun whin 180 days of Issuance, or if work is suspended or abandoned for a Period of 180 days APR 16 2015 (3so) 4583845 1@5 Yelm Aumw West (360) 458-4144 FAX YeIR4 WA 98597 &vww.ci yel+n.wa.us ify of Yelm, CD Approved W 2' MINIMUM SETBACK g BETWEEN SIDEWALKS, z DRIVEWAYS, EASEMENTS, AND STEP TANK. zs -rb 3 c A 18, 11six. ,T�ER m ";A Y. .L__ � p, NOTES: 1. FRONT PORCH FOUNDATION AND STEP TANK LOCATION SHALL BE STAKED OUT FOR SET BACK INSPECTION. 2. STEP TANK IN VIOLATION OF THE REQUIRED 5' MINIMUM SETBACK TO FOUNDATION SHALL BE BACK FILLED WITH CDF. 3. CONNECT PVC ROOF DRAINS TO DRYWELL. CONTACT INFO TANER: (253) 848 -0820 SCALE. 1 " =20' 0 10 20 40 THOMA TERRA - PH . - DIVA LOT- 164 S 8970'95" E DItX1Y ELL PER as �NmTAV STANDAR 0 5'y Vii® I t i i i i i i 5'; C. 1 1741A9 -2 ELEV. —A O (1 STORY) (0 4 BDRM ' SIDE WALX GARAGE 5' �r I xl I CURB-- 99TH AYE SE�'�� t I� APR 16 2015 Ampaul SOUNDBUILT HOMES, INC. P.D. BOX 73790 PUYALLUP, WA 98373 PH C253> 848 -0820 FAX, (253) 539 -0514 %. I I 1 V1 I L=L1 "1 THURSTON COUNTY 14434 99th Ave. SE. Yelm, WA 98597 PARCEL# 78640101640 PZ 04/14/15 R1,0 :e ;7,dIS-C /7 Z, Property Address: S, & L,1(04 Conditioned Floor Area: 1 ZLi Date: Builder or registered design pro ssional Si nature: R- Values Ceiling: Vaulted R- Floors: Over unconditioned space R- Attic R- Slab on grade floor R- walls: Above grade R- Doors: R- Below, int. R- —R- Below, ext. R- - R-U-Factors and SfIGC - NFRC rating (or) Windows U- SllGC- N/A Default rating (Appendix A WSr.•.0 2012) Skylights U- SHGC- N/A Table 406.2 Option(,) Total 406.2 Credits Heating, Cooling & Domestic Hot Water Systapi Type Efficiency a Heating l IJ Cooling DHW 1 Duct R Building Air Leakage 1 All ducts & HVAC in conditioned space ( yes no Insulation R- Air handler present ( yes io ) Test Target ((pq CFM @25Pa Test Result Z!9�3 CFM(at25Pa Building air leakage target: AC1150 < 5.0 -Tested leakage: AC1150 _ Unsite Renewable Energy Electric Power System System type: Rated annual generation I {ti�h Duct Leakage Affidavit (New Construction) Permit House address or lot number: � 1 City: _ Y L r_ �� Zip: Cond. Floor Area (ft): 1 Source (circle one): Plans Estimated Measured ❑ Duct tightness testing is not required. The total leakage test is not required for ducts and air handlers located entirely within the building thermal envelope. Ducts located in crawl spaces do not qualify for this exception. Air Handler in conditioned space? ❑ yes Mno Air Handler present during test? L'J yes ❑ no Circle Test Method: Leakage to Outside Total Leakage Maximum duct leakage: Post Construction, total duct leakage: (floor area x.04) = CFM @ 25 Pa Post Construction, leakage to outdoors: (floor area x .04) = CFM 25 Pa Rough -In, total duct leakage with air handier installed: (floor area x .04) _ ( ( CFM 25 Pa Rough -In, total duct leakage with air handier not installed: (floor area x.03) = CFM 25 Pa Test Result: t) T CFM @25Pa Ring (circle one if applicable): Open Duct Tester Location: G /A 3 Pressure Tap Location: 5 A I certify that these duct leakage rates are accurate and determined using standard duct testing protocol. Company Name: � AT I Technician: Z' Technician Signature: Date: Phone Number: Building Address City of Yelm Community Development Department Residential Certificate of Occupancy M Colti ]II: \TJl_yd6410 Owner Name SOUNDBUILT NW LLC Owner Address PO BOX 73790 PUYALLUP WA 98373 Building Permit Number 20150172 Remarks: LOT 164, PLAN 1741A Areas Inspected ALL CODE REQUIRED Special Conditions Building Official & CARLSON Plan Number 1741A Date: October 20, 2015 This structure is in compliance with the International Residential Code (Chapter 51 -51 WAC) as adopted by the Washington State Building Code Council pursuant to Chapters 19.27 and 70.92 RCW, effective July 1, 2004