Loading...
20040134 City of Yelm Community Development Department Building Division Phone: (360) 458-8407 Fax: (360) 458-3144 Permit No M-04-0134-YL Issue Date 10/14/2004 (Work must be started within 180 days) Receipt No 33460 f\pp!i9ant: Name. AAA Fire and Safety Phone 206-284-1721 Address 3013 3rd Ave. North City' Seattle State WA Zip Prope!!YJ6!.qrfu~tiqll: Site Address. 1202 Yelm Ave. E Assessor Parcel No 22730110103 Subdivision' Lot: COhtracto[informatior;l Name Applicant Contact: Phone Address. City' State. Zip. Contractor License No AAAFISI140DS Expires. 01/05/055 Business License: Project Information Project: Dairy Queen Description of Work: Hood Suspression System Sq Ft. per floor' (1st) 2640 (2nd) 0 (3rd) 0 Garage 0 Basement 0 Heat Type (Electric, Gas, Other) GAS Fees. Item Item Fee Base Amt Unit Fee Unit Rate No Units Unit Desc Mechanical Permit TOTAL FEES 2950 $29.50 000 000 o 0000 o 0000 Applica~fs Affa<!~vit: ..OFFICIA~ USE.ONL Y . ~.Sets of Prints. I certify that I have read and examined the information contained within the application and know the same to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of Yelm regulations including those governing zoning and land subdivision, and in addition, all covenants, easements and restrictions of record. If jP ing as a contractor I futher certify that I am currently registered In the tate of WaShingt"Oii") I . Signatur (A)' t. Date !O' / c..j - €I ~ Firm #. Finallhspection: Date: By' City of Yelm Community Development Department Building Division Phone. (360) 458-8407 Fax: (360) 458-3144 Applicant: Name AAA Fire and Safety Address. 3013 3rd Ave. North City' Seattle Project Information Project: Dairy Queen Description of Work: Hood Suspression System Assessor Parcel No 22730110103 Site Address. 1202 Yelm Ave. E Fees Item Mechanical Permit Acct Code Item Fee Base Amt Unit Fee 000 "- \V~) Permit Fees Schedule Phone: Permit No M-04-0134-YL State' WA Zip 98109 206-284-1721 Unit Rate o 0000 No. Units Unit Desc o 0000 032 001-322-10-00 2950 000 TOTAL FEES $29.50 1) ()~ r ~ f)1 ~fi#!~:i~!r~*~~~~~~_OJ=>~I!I~~~~~~~~~~~~~JJ~D'L~~~~-~"'~:~~i~~t~_I\~_l~"'::~"_::."~E!.~~-~'~~'!:~:':-"T'<-: "'f:<. i er- y.~;lrF1 l'-./~ 9859-:' 3t::O-4S?'-;~403 RECEIPT No 33450 i RECE!VE.D ****TWENTY NINE DOLLARS & 50 CENTS RECEiVCD F~Ul\'l O,L\TE ;:r=~ NO '.),fv1Ul Jr,rr HEF i'11_ AAA FIRE A sAFETY 3013 3RD AVE N SEATTLE. WA 98109 10/14/04 33460 29.50 CHECK 29043 MISCELLANEOUS RECEIPT JANINE MECHANICAL PERMIT ---- '-+7~-31'1't 4<iB .- l./~ 48 BALL POINT P~N ONLY r\'~~~ ,itYl( r. "$' '17 1'1 t.. ;..\:.;..)}c'j!> ''),-+ I de~.l.44 , . ""FOR (jFFICEU~E OI'\LY , h' ,,0\'\ ....\, 1 O());tV'\ \. ~1 . Ue<l f' f~ H~aTih Food Service Establishment Inspection Report .X ~ ".~ f~~se:items 'relate directly to the protSGtion oft~e;publicffom foodborl7ls illnes~. th item~ C!r6 N1() . N~'Or.IABLI!AIil/lDM'ijSTBIE CORRECTED \I..MEDI~TI!!LY 'Repeatedvioli\ition~ off:lnY~EDITEMfnay.\leaato enf6rc,em~nt actionspeing .iriitilitedor permit suspension. " - ' , - ",t _ " ' ITEMS HAZARD . POiNTS · th.~se it~ms'relate tomainte~ai;lce,6ff?8d service 9PElratiq~~'.~ri?cleanlinciis.ViqlC!!i9hsJbHhese itefiisshouldbe"soire6iedbY t~~:riext regul~r.irispecti6n 'or. ' ,a,'c,qmpllance schedulemay.be established bytheh,~althau!hc;inty . ,,'. .'" .." .... ~, .. .. """l. . HAZARD . 'ITEf1S . "GESC~IPTI0N.6F ,VIOLATIONS; .". ' POINTS \ ;Ilk'; ., . ,!-'I' :1_ , ',1'~' . , ' ;~, , '.~ ..~ 't <t=.. ." --it. , 1. ~ '~ , ; " ,..J~ ,~~ 'I' .,. :1, .! .. >'1; j' )'t': t, "'t" .. 1: ~l' -, '9?mments / "1 .';' Total Points ./i DOH 334-001 (Rev 5/93) ./ Look Up a Contractor, ElectncIan or Plumber License Detail Page 1 of 3 Topic Index Contact Info Safety Claims & Insurance Workplace Rights Trades & Licensing Find a Law or Rule I Get a Form or Publication Look Up a Contractor, Electrician or Plumber General/Specialty Contractor A business registered as a construction contractor with Lal to perform construction work within the scope of its specialty A General or Specialty construction Contractor must maintain a surety bond or assignment of account and insurance License Information License AAAFISI140DS Licensee Name AAA FIRE a SAFETY INC Licensee Type CONSTRUCTION CONTRACTOR UBI 600579238 Verify Contractor Premium Status Ind Ins. Account Id Business Type CORPORATION Address 1 3013 3RD AVE N Address 2 City SEATTLE County KING State WA Zip 98109 Phone 2062841721 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 3/10/1986 Expiration Date 1/15/2005 Suspend Date Separation Date Parent Company Previous License AAAFIEC153DD Next License Associated License Business Owner Information Name I Role I Effective Date https.//fortress wa.gov/lm/bblp/detall.aspx?Llcense=AAAFISI l40DS 9/3/2004 FEB-06-2QOJ ll4 158 y Q 1 m CDr, 360 4158 3144 F n~ Project Address: I Z 0 Z ,/J: Lrn .A t/t'. / Zoning, . Current Use: Proposed Use. I'Jfi//Z ~ ()u~,( 2f' New Construction 0 Re-Modell Re-Roof r Tenant Improvement / 0 Plumbing 0 Mechanical 0 Fire Prevent/Suppress/Alarm 0 Other Project DeSCrip,scope of Work: INS T/JU QTi/J A) flIt. 3LO ;,..fqUJ S uP.P/2t;fS/o.# Project Value: ~7~ CITY OF YELM ~~C~ COMMERCIAL BUILOING PERMIT APPLlCA'1'ION FORM J'E,P I!/ ~ 7 .. 0< 0 Parcel #. ~ ~t.l J J ,,, ! n '~ ItJ{.~ Building Area (sq. ft) Parking Garage Building Height Are there any environmentally sensitive areas located on the parcel? completed environmental checklist must accompany permit application 111 Floor 2RC Floor~3rc: Floor_ If yes, a BUILDING OWNERJTENANT NAME. ADDRESS CITY STATE: ZIP EMAlL TELEPHONE LICENSE # EMAlL. TELEPHONE ARCHITECTJENGINEER ADDRESS CITY _ STATE ZIP GENERAL CONTRACTOR ADDRESS CITY STATE ZIP CONTRACTOR'S LICENSE # TELEPHONE EMAlL FAX EXP DATE CIlT' LICENSE 1# PLUMBING CONTRACTOR ADDRESS CITY STATE ZIP CONTRACTOR'S LICENSE # TELEPHONE EMAIL FAX EXP DATE CIlT' LICENSE # MECHANICAL CONTRACTOR "/t2e ffi TELEPHONE ADDRESS 3'0/3 31Jti) Aoe. NO EMAIL CITY ~tA1TI;: STATE wA ZIP Yi-JOe; FAX CONTRACTOR'S LICENSE., AfI. J.J S J J~I OS EX? DATE~ITY LICENSE # Copy of City Mitigation dOcumentation (TI"C). ^ ~ ~ I h....by certify that the above infonna'lion Is eomtct !Inc\ that th8 construction 011, and tt, "\Yp P of tl'le above described property wID ~ In accordance with the laWs. rule$ and regulatlor (\ J LA V _ I WashltlgtonllnlltlvtC ofY.lm, ~- .~d ~ ~ ~ ~,l?) \'L\6~ Dat Tenant (Plea All permits are non-transferable and 'U-eXtHr-' ork authorized by such permit Is not begun within 180 days of issuanoe. or if work is suspended or abandoned for a period of 180 days R:\Forms &: ProccdureslBuilding Pcrmits\CommBldllPermitAplUloc Page 2 of4 AdOO 3'IJ 111111 ARA FIRE & SAFETY INC.~ ~ ~ \ \ I I , I \ i 1 \ 1 \ \ , , \ 3013 3rd AVENUE NORfH SEATTLE. WASHINGTON 98109 206- 284-1721 FAX 206- 284-1769 1(j ~ '"'- CI N :?- \ ..) ;) ~ '-<.!. 'o.j .... ,'t N '" ,J tJ ~{ ~ ~ J ~ () 1, ~ '-D J' ~ ~ - N t.J -- N ~ :>- ~ rJ 1- M ....... 0 j\ ~I I \ \\ \ 31 \ ~ \ \ \ \, ~ ! . ,n ~ -...... N '-<:.. \1 ~ l:><> I"') rJ t...:) ~ 01 ...J ~\ <;:: 9 v "\ 'Y) I I '\ ~I ~:&\ 3.\ \ ~\ \ \ ~\ /\. ~'\~I ,.I ! \ \ \ )/ N'.f frr> M '" 1 J \) ':::) \--. .j ~ V) o J) "'- ~ "" ~ ), I..... '" IJ! --... \- ~ ..... v ~ ] .;) '-,j '--' '-.? ..... ~ ~ " ~ \J" \ o <::'>~ \)Q ..-J \ ~ ~ ~ I -... ~ \ ~ ~ ~ ~ 1 ~ ~ ~ ~ \ ~I ~ ;:; ~ ~I \ "I \"') \ "Zi '" \ ~\ ~: - \ \ IN! ~ \'0\, ;: J~ \ ~ f> ~ ~"'&:>- ; '~l4[ :>~ .~~I lL-- 6 . '-I---~ \ %JI \ 1'0 ~ ~ [f-__ \ J ~ ~ ~ "~~!-1 ~6 ~ I' ~ ~ l----h\~[ ~ \' ~~! \ - '-' _ ~ r.) ::c, \ ..-.J 1-'''' _I r-.) :::: ",I \ ",,~I \ -'( ~ -N I[ ...J, t"\ =..... '" \ '.:: 11M'" ~ \ ~! \'1" ~~ &1 \ I 1 I I i ] \) -v 't\ \ \J I "-\ I I -..J \~ \~ I I \ I i \ \ ,-,/", r (' ('"it <..:.- - :r -r $1 " :"/.[ fl'(j ,vr;{({/) () f.. v_ ;y?[;/ ,,-YT SYSTEM DESIGN The Ansul R-102 Restaurant Fire Suppression System may be used on a nurnber of different types of restaurant cooking appli- ances and hood and duct configurations. The design information listed in this section deals with the limitations and parameters of this pre-engineered system. Those individuals responsible for the design of the R-102 system must be trained and hold a current Ansul certificate in an R-102 training prograrn. The R-102 and the PIRANHA systems use cornpatible agents and components, therefore, they may be used together for cooking appliance, hood, and duct protection. The primary ANSUL AUTOMAN Release can be either an R-102 or a PIRANHA ANSUL AUTOMAN Release and can actuate up to two additional R-102 or PIRANHA Regulated Actuators. In systems utilizing a 101 rernote release, any combination of the maxirnum number of regulated actuators can be used. Both systerns must actuate simultaneously . Each system must be designed and installed per its appropri- ate rnanual. . Adjacent appliances requiring protection must be protected with the sarne type of system, either R-102 or PIRANHA, unless the center-to-center spacing between the adjacent R-102 and PIRANHA nozzles is no less than 36 inches. When appliances are protected with R-102 nozzles, the hood and connecting duct above those appliances cannot be pro- tected with PIRANHA nozzles. . Mixing systems in a common plenum is not allowed. One of the key elements for restaurant fire protection is a correct system design. This section is divided into ten sub-sections: Noz- zle Placement Requirements, Tank Quantity Requirernents, Actu- ation and Expellant Gas Line Requirements, Distribution Piping Requirernents, Detection System Requirements, Manual Pull Sta- tion Requirements, Mechanical Gas Valve Requirements, Electri- cal Gas Valve Requirements, Electrical Switch Requirements, and Pressure Switch Requirements. Each of these sections must be completed before atternpting any installation. System design sketches should be made of all aspects of design for reference during installation. ~ NOZZLE PLACEMENT REQUIREMENTS This section gives guidelines for nozzle type, positioning, and quantity for duct, plenum, and individual appliance protection. This section must be completed before determining tank quantity and piping requirements. Duct Protection - Single Nozzle All duct protection is UL listed without limitation of maximum duct length (unlimited length) This includes all varieties of ductworks both horizontal and vertical including ducts that run at angles to the horizontal and ducts with directional bends. The R-102 system uses different duct nozzles depending on the ~ size of duct being protected. SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-1 10-1-02 REV 5 ~ GENERAL INFORMATION 1 Nozzles must be located 2-8 in. (5-20 cm) into the center of the duct opening, discharging up. See Figure 1 2-8IN. (5 - 20 em) FIGURE 1 000173 2. In installations where a UL listed damper assembly is employed, the duct nozzle can be installed beyond the 8 in. (20 cm) maxirnum, to a point just beyond the damper assem- bly that will not interfere with the damper Exceeding the maxi- mum of 8 in. (20 cm) in this way will not void the UL listing of the system. 3. Previously listed 3 flow number and 5 flow number duct pro- tection detailed in earlier published rnanual, Part No. 418087- 06, can also still by utilized. DUCT SIZES UP TO 50 IN. (127 cm) PERIMETER! 161N. (41 crn) DIAMETER One 1100 nozzle (Part No. 430912) = one flow number . 50 in. (127 cm) perimeter maximum . 16 in. (41 cm) diarneter rnaxirnurn DUCT SIZES UP TO 100 IN. (254 crn) PERIMETER! 32 IN. (81.3 crn) DIAMETER . One 2W Nozzle (Part No. 419337) = two flow numbers . 100 in. (254 cm) perimeter maxirnum . 32 in. (81 3 cm) diameter maximum . A 2WH nozzle (Part No. 78078) must be substituted for a 2W nozzle for any installation using Option 2 of the 1.5 gallon sys- tem coverage (duct and plenurn protection only). A 2WH nozzle is limited to a maximum of 75 in. (190 cm) perirneter or a rnaxi- murn diameter of 24 in. (61 cm) of coverage. The chart below shows the maximurn protection available frorn each duct nozzle. Part 3.0 Gallon 1.5 Gallon !?~scriptio!:1 No. ~ys~ern __ Sy~te~_ 2W Nozzle 419337 Maxirnum Maximum 100 in. (254 crn) 100 in. (254 crn) Perimeter Perimeter 1100 Nozzle 430912 Maximum Maximum 50 in. (127 crn) 50 in. (127 cm) ~ Perimeter Perimeter SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-6 REV 4 10-1-02 Plenum Protection (Continued) ~ HORIZONTAL PROTECTION - OPTION 2 1100 NOZZLE - PART NO 430912 - 'V" BANK PROTECTION 1W NOZZLE - PART NO. 419336 One 1100 or 1W nozzle will protect 6 linear feet (18m) of "V" bank plenum. The nozzle must be mounted horizontally, positioned 1/3 the filler height down from the top of the filter Nozzles can be located at 6 ft. (1.8 rn) spacings on longer plenurns. See Figure 10 1100 NOZZLE OR 1W NOZZLE ~H) t HEIGHT OF FILTER (H) I_4FT i -I (1.2 m) MAXIMUM ~ FIGURE 10 006524 1 N NOZZLE - PART NO 419335 - "V" BANK PROTECTION Two IN nozzles will protect 10 linear feet (3.1 m) by 4 ft. (1.2 m) wide of 'V" bank plenum. The nozzles must be mounted in the plenum, 2 to 4 in. (5 to 10 cm) frorn the face of the filter, centered between the filter height dimension, and aimed down the length. See Figure 11 / > ~'- 4 IN. (5-10cm) 000203 \_4 FT. (1.2m)__1 MAXIMUM ~ FIGURE 11 For a plenum, either single or "V" bank, with a linear extension longer than 10 feet (3.1 m), each bank may be protected using one 1 N nozzle every 10ft. (3.1 m) or less depending on the overall length of the plenum. See Figure 12. The nozzles may point in the opposite directions as long as the entire plenum area is protected, and the 10ft. (3.1 m) limitation is not exceeded. See Figure 13. The nozzle positioning shown in Figure 14 is not an acceptable method of protection because the plenum area directly under the tee is not within the discharge pattern of either nozzle. 10 FT. (3.1 m)/ MAXIMUM FIGURE 12 000206 10 FT. (3.1 m)/ MAXIMUM FIGURE 13 000207 FIGURE 14 000208 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-8 REV 5 10-1-02 Fryer - Single Nozzle Protection (Continued) Maximum Area Dimensions - Single Nozzle Fryer Protection Max. Size Overall ~~~P.!ipb_~rd Full or Split Vat 14 in. x 21 in. (36 crn x 53 cm) Max. Size Ery.F-0_Q.t:l!L Full or Split Vat "14in.x15in. (36 cm x 38 em) Type of Nozzle 230 Full or Split Vat .. 14 in. x 15 in. (36 cm x 38 cm) Full or Split Vat 14 in. x 21 in. (36 cm x 38 cm) 245 ...--1' -. (::. , ...-' I -'I!'/ I ,I I ,I I II I " I II I I' I ,I I I' , II , .... 'l"-..... ....""' I ..... ~/- I.-- I..... .....- I -'1- I I I I I I I I I I I : I I I I , I I I I I I I I I I I I I I I I I FRYER WITHOUT DRIPBOARD FRYER WITH ORIPBOARD NOZZLE TIP POSITIONED ANYWHERE ALONG OR WITHIN PERIMETER OF COOKING SURFACE AND AIMED TO THE CENTER OF THE COOKING AREA .. FIGURE 15 002280 Nozzle Height Ab.9~~"!92_~~E~~_ 27 in. to 47 in. (69 cm to 119 crn) Nozzle Location See Figure 15 and 16 20 in. to 27 in. (51 cm to 69 cm) See Figure 15 and 16 ........-"f..........,_ ,< J .... I '---y,--- I II : II I II I I' I II I II I II I II I IJ I Ii I II I Ii : 'I I I / - --r---., f--- I / I......' .....r...... I I "I I I I I I I /: I I I I I I I I I I I I I: I I I I I I I I I I I I I I I FRYER WITHOUT ORIPBOARD FRYER WITH DRIPBOARD SPLIT VAT NOZZLE TIP POSITIONED ANYWHERE ALONG OR WITHIN PERIMETER OF COOKING SURFACE AND AIMED TO THE CENTER OF THE COOKING AREA. .. FIGURE 16 002283 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-19 10-1-02 REV 3 2-Flow Griddle Protection (Continued) Option 2 - Nozzle Perimeter Located High Proximity Application: 30 in. to 50 in. (76 em to 127 em) above the cooking surface. This high proximity application uses the 260 nozzle, Part No. 419341 The nozzle tip is stamped with 260 indicating this is a two-flow nozzle and must be counted as two flow numbers. One 260 nozzle will protect a maximum cooking area of 1440 sq. in. (9290 sq. cm) with a maximum dirnension of 48 in. (122 cm). When using this nozzle for griddle protection, the nozzle must be positioned along the cooking surface perimeter to 2 in (5.1 em) inside perimeter, and aimed at the center of the cooking .. surface. See Figure 39 and 40 .. COOKING AREA , , r-t--;:;D;;;;:;;-~--' I COOKING SURFACE I ..- f- r / I COOK I ' AREA f-t. I AIM POINT I 1 1- . I L--_______-1 t J ING t 50 IN. (127 em) MAXIMUM Ii ~ ~~'~:oT I I t NOZZLE TIP / I 30 IN (76 em) 260 NOZZLE LOCATED ALONG COOKING SURFACE EDGE ANY SIDE OF GRIDDLE SURFACE WITHIN 0 2 IN. (0 - 5 em) OF COOKING SURFACE EDGE. NOZZLE MUST BE AIMED AT MIDPOINT OF COOKING SURFACE. I I NOZZLE LOCATION I I 0 _ 2 IN. (0 - 5 em) I I INSIDE PERIMETER _I ,_ OF COOKING SURFACE II II I' 11 I J 11 II II EDGE 1,1 OF--I COOKING I J SURFACE I I .. FIGURE 40 000241 MINIMUM HEIGHT OF 260 NOZZLE TIP 000243 .. FIGURE 39 000243 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-24 REV 5 10-1-02 Electric Char-Broiler Protection The R-102 system uses the 1 N nozzle for the protection of electric char-broilers. The maximum length of the hazard can be no longer than 34 in. (86 cm) and the total cooking area must not exceed 680 sq. in. (4388 sq. cm). 1 Nozzle Location. 20 to 50 in. (51 to 127 cm) above the grate surface. The 1 N Nozzle (Part No. 419335) is used for electric char- broiler applications. The nozzle tip is stamped with 1 N, indi- cating that this is a one-flow nozzle and rnust be counted as one flow number When using this nozzle for electric char-broiler protection, the nozzle must be positioned anywhere along or within the perimeter of the maxirnum cooking area and shall be aimed at .. the center of the cooking surface. See Figure 50 COOKING 1 AREA ~ COOKING I~ AREA ....---....,............ ~ ..,....... I ...................... f....... t ....., I ........ I ......... ........!..... .....--"1 I I .......... ......... I I I .....,......... I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I l ~I! In I: J I \ .:;:. /: ::::,:.'J, ~\ 1',0 I I ~~~~6M I I 000254 .. FIGURE 50 Gas-Radiant Char-Broiler Protection The R-102 system uses the 1 N nozzle, (Part No. 419335) for gas- radiant char-broiler protection. The nozzle tip on the 1 N nozzle is stamped with a 1 N, indicating that this is a one-flow nozzle and must be counted as one flow number One IN nozzle will protect a hazard with a maxirnum length of 36 in. (91 cm) and a total cooking area which does not exceed 864 sq. in. (5574 sq. cm). The nozzle tip must be located 15 to 40 in. (38 to 102 crn) above the hazard surface. When using this nozzle for gas-radiant char-broiler protection, the nozzle must be positioned anywhere along or within the perimeter of the maximum cooking area and shall be airned at the center of the cooking sur- .. face. See Figure 51 ~ ! l\ I I I \~/I~ ~ ' I, //l15IN \38cm) I' I MINIMUM I I I t 40 IN. (102 em) MAXIMUM 000257 .. FIGURE 51 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-46 REV 3 10-1-02 DISTRIBUTION PIPING REQUIREMENTS (Continued) Distribution Piping Requirements - 3.0 Gallon System 1 The maximum length between the start of the first branch line and the start of the last branch line rnust not exceed 24 ft. (7.3 m). When the supply line is split, the combined total of both legs of the supply line (from the start of the first branch line to the start of the last branch line) must not exceed 24 ft. ~ (7 3 m) See Figure 84 2. The total length of all branch lines must not exceed 36 ft. ~ (10.9 m) See Figure 84 3 Use a 3/8 in. union to connect the tank adaptor to the 3/8 in. supply line. 4 A maximum of two nozzles are allowed per duct branch line. 5 The requirements of the following table must not be exceeded: COMBINED LENGTH OF BOTH LEGS OF SUPPLY LINE MUST NOT EXCEED 24 FT. (7.3 m) 3 BRANCH LINES (BRANCH LINE IN BOLD) COMBINED LENGTH MUST NOT EXCEED 36 FT. (10.9 m) 000502 ~ FIGURE 84 Duct Plenurn Appliance Requirements Supply Line Branch Line Branch Line Branch Line Pipe Size 3/8 in. 3/8 in. 3/8 in. 3/8 in. Maximum Length 40 ft. 8 ft. 4 ft. 12 ft. (12.2 m) (2.4 m) (1.2 rn) (3.7 m) Maximum Rise 6 ft. 4 ft. 2 ft. 2 ft. (18m) (1.2 rn) (.6m) (6m) Maximurn 900 9 4 4 6 Elbows Maxirnum Tees 1 2 2 4 Maximum Flow 11* 4 2 4 Numbers *Exceptions: 1 Twelve (12) flow numbers are allowed in anyone tank not containing two-flow appliance nozzles, andlor, a 1 N nozzle for wok or griddle protection, and/or, a 1 F nozzle for range protection. and/or. a 3N nozzle for fryer protection. ~ 2. Twelve (12) flow numbers are allowed in anyone tank for hood and duct protection. 3. Twelve (12) flow numbers are allowed with anyone tank using only two-flow appliance nozzles. 4. Twelve (12) flow numbers are allowed with anyone tank using only three-flow appliance nozzles. Special Instructions: 1 Twelve (12) flow numbers are allowed when four (4) Dean Industries GTI Gas Fryers are protected at low proximity as shown in Figure 101 on Page 4-52. The discharge piping must be as shown in Figure 102 on Page 4-52. 2. For certain McDonald's applications, 11.5 flow numbers are allowed when using a combination of one (1) 2W duct nozzle, one (1) 1/2N electrostatic precipitator nozzle, one (1) 1N plenum nozzle, and four (4) two-flow appliance nozzles. Contact Ansul Applications Engineering Department for additional information. SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-48 REV 2 10-1-02 DISTRIBUTION PIPING REQUIREMENTS (Continued) Distribution Piping Requirements - 6.0 Gallon Manifolded System (Continued) This configuration consists of two 3 gallon tanks. Both tanks are connected to a comrnon manifold tee and are pressurized from a single double tank (Part No. 73022) nitrogen cartridge in the regu- ,. lated release assembly. See Figure 86. USE HOSEI GROMMET PACKAGE (PART NO. 418511) 3/8 IN. BRANCH 3/8 IN. 3/8 IN. j SUPPLY SUPPLY ~ ~"~~"'M"" SUPPLY D 3.0 3.0 GALLON GALLON ,. TANK TANK DOUBLE TANK NITROGEN CARTRIDGE OR LT-A-101-30 CARTRIDGE (REGULATED ACTUATOR ONLY 3.0 GALLON REGULATED RELEASE ASSEMBLY OR 3.0 GALLON REGULATED ACTUATOR ASSEMBLY TANK/ENCLOSURE ASSEMBLY NOTE 1. THE PIPE CONNECTION FROM TANK CENTER TO TANK CENTER CANNOT EXCEED 8-1/2 IN. (21.5 em). ALSO, OEM RELEASE/BRACKET ASSEMBLY CAN BE UTILIZED WHEN MANIFOLDING 3.0 GALLON TANK. NOTE 2: ONLY 3 GALLON TANKS CAN BE MANIFOLDED. ,. FIGURE 86 000272 When using the hoselgrornmet package, independent pipe runs can also be used with the regulated release assembly and the ,. tank/enclosure assembly. See Figure 87 NOTE. When manifold- I ing is not used, each of the two (2) 3 gallon tanks utilize the piping ,. limitations of a single tank system. r~~ q==;;r=~ HOSEI GROMMET PACKAGE (PART NO. 418511) D D 3.0 GALLON TANK OR 1.5 GALLON TANK TANK/ENCLOSURE ASSEMBLY REGULATED RELEASE ASSEMBLY OR REGULATED ACTUATOR ASSEMBLY DOUBLE TANK NITROGEN CARTRIDGE OR LT-A-101-30 CARTRIDGE (REGULATED ACTUATOR ONLY) ,. ,. FIGURE 87 000786