Loading...
20150238 Permit Pkg 07282015City of Yelm Community Development Department Building Division Phone: (360) 458 -8407 Fax: (360) 458 -3144 Applicant: Name: YELM COMMUNITY SCHOOLS Address: P.O. BOX 476 YELM WA 98597 Property Information: Site Address: 10605 MILL RD SE Permit No.: 20150238 Issue Date: 7/28/2015 (Work must be completed within 180 days) Phone: 360- 458 -1900 Owner: YELM COMMUNITY SCHOOLS Assessor Parcel No.: 21725140100 Subdivision: Contractor Information: Name: YELM COMMUNITY SCHOOLS Phone: Address: P.O. BOX 476 YELM WA 98597 Contractor License No.: Expires: 0 /00 /0000 Project Information: Project: NEW COMMERCIAL BUILDING Description of Work: CONSTRUCTION OF A 3,841 SF TYP IIN STEEL PLAYSHED Sq. Ft. per floor: First 3841 Heat Type (Electric, Gas, Other): Second Third Garage Basement Fees: Item Contractor NEW COMMERCIAL BUILDING YELM COMMUNITY SCHOOLS TOTAL FEES: Applicant's Affidavit: I cert ify th't I have read and examined the information contained within the application and know the same to be true nd correct. I also certify that the proposed structure is in conformity with all applicable City of Yelm reg lations including those governing zoning and land subdivision, and in addition, all covenants, easement n restric of record. If applying as a contractor, I further certify that I am currently / registered in th State of ashington. Signature`'o, Date �i • p�q. Ilj _ Firm r Lot: Fees $ 2,568.18 $ 2,568.18 OFFICIAL USE ONLY # Sets of Prints: Final Inspection: Date: By: City of Yelm (36) 458 -3244 REC #: 00202240 7/28/2015 11:35 AM OPER: CO TERM: 001 REF #: 70125522 PAID BY: TRAN: 33.0000 BUILDING PERMITS 20150238 2,568.18CR YELM COMMUNITY SCHOOLS 10605 MILL RD SE BLD -COM1 2,568.18CR TRAN: 33.0000 BUILDING PERMITS 20150239 1,875.18CR YELM COMMUNITY SCHOOLS 203 FIRST ST N BLDG 1,875.18CR TENDERED: 4,443.36 CHECK APPLIED: 4,443.36 - CHANGE: 0.00 JA 0,238 CITY OF YELM COMMERCIAL BUILDING PERMIT APPLICATION FORM Project Address: 10605 Mill Rd, SE Yelm, WA Parcel #: 21725140110 Zoning; PU Current Use: Elementary Proposed Use: Occ A -3 Playshed / Noncombustible X New Construction i Re -Model / Re -Roof / Tenant Improvement Plumbing Mechanical Fire Prevent/Suppress /Alarm Other Project Description /Scope of Work: Construction a one 3,841 S.F. Tvp IIN steel playshed Project Value: $200,000.00 Building Area (sq. ft) Parking Garage l" Floor 3.841 2nd Floor 3 "' Floor Building Height Are there any environmentally sensitive areas located on the parcel? No If yes, a completed environmental checklist must accompany permit application. BUILDING OWNER/TENANT NAME: Yelm Community Schools No.2 ADDRESS P.O. Box 476 EMAIL Chris Hansen - chris_hansen ®ycs.wednet.edu CITY Yelm STATE 'NA ZIP 08507 TELEPHONE 360- 458 -6128 ARCHITECT /ENGINEER Raymond Mow, AIA LICENSE # 7120 WA State Architect ADDRESS 101 E 26th Street. Suite 300 EMAIL ray@ericksonmcgovern.com CITY Tacoma STATEWA ZIP 08421 TELEPHONE 253 -531 -0206 GENERAL CONTRACTOR TBD Public Bid TELEPHONE ADDRESS EMAIL CITY STATE ZIP FAX CONTRACTOR'S LICENSE # EXP DATE CITY LICENSE # PLUMBING CONTRACTOR TELEPHONE ADDRESS EMAIL CITY STATE ZIP FAX CONTRACTOR'S LICENSE # EXP DATE CITY LICENSE # MECHANICAL CONTRACTOR TELEPHONE ADDRESS EMAIL CITY STATE ZIP FAX CONTRACTOR'S LICENSE # EXP DATE CITY LICENSE # Copy of City Mitigation documentation (TFC). I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above described property will be in accordance with the laws, rules and regulations of the State of Washington and the City of Yelm. Raymond Mow y , 1 `, Applicant's Signatu a Date Owner / Contractor Contractor's Agent / Tenant (Please circle one.) All permits are non - transferable and will expire if work authorized by such permit is not begun within 180 days of issuance, or if work is suspended or abandoned for a period of 180 days (360) 458 -3835 105 Yelm Ave W (360) 458 -3144 FAX Yelrn, WA 98597 www.ci.yelrmura.ns E 0 o MILL POND ELEMENTARY SCHOOL PLAYSHED PARCEL NUMBERS 21725140100 SITE AREA 31.8 ACRES 1.385.533 SF LEGAL DESCRIPTION THE NORTH HALF OF THE SOUTHEAST QUARTER OF THE NORTHEAST QUARTER OF SECTION 25. TOWNSHIP 77 NORTH, RANGE 1 EAST. WILLAMETTE MERIDIAN. IFOR ENHANCED DESCRIPTION AND SURVEY OF THIS PARCEL SEE RECORD OF SURVEY BY KEYES 8 ASSOC, P.S., INC .I OCCUPANCY TYPE BUILDING AREA GROUP E TOTAL AREA = 3.841 S.F. CONSTRUCTION TYPE BUILDING HEIGHT 1 STORY - 23' -3" MAXIMUM HEIGHT (-ODF INFORMATinN r 2012 INTERNATIONAL BUILDING CODE W/ WASHINGTON STATE AMENDMENTS 2012 INTERNATIONAL FIRE CODE 2012 INTERNATIONAL MECHANICAL CODE 2012 INTERNATIONAL PLUMBING CODE W/ WASHINGTON STATE AMENDMENTS 2012 NREC BARRIER FREE - INTERNATIONAL CODE COUNCIL - ANSI STANDARD 117.1 ARCHITECTURA1 PRn.IFCT INFqRMATpN r SITE ADDRESS ZONING 10605 MILL RD. S.E. PU. PUBLIC USE YELM, WA 98597 n DOOR NUMBER PARCEL NUMBERS 21725140100 SITE AREA 31.8 ACRES 1.385.533 SF LEGAL DESCRIPTION THE NORTH HALF OF THE SOUTHEAST QUARTER OF THE NORTHEAST QUARTER OF SECTION 25. TOWNSHIP 77 NORTH, RANGE 1 EAST. WILLAMETTE MERIDIAN. IFOR ENHANCED DESCRIPTION AND SURVEY OF THIS PARCEL SEE RECORD OF SURVEY BY KEYES 8 ASSOC, P.S., INC .I OCCUPANCY TYPE BUILDING AREA GROUP E TOTAL AREA = 3.841 S.F. CONSTRUCTION TYPE BUILDING HEIGHT 1 STORY - 23' -3" MAXIMUM HEIGHT (-ODF INFORMATinN r 2012 INTERNATIONAL BUILDING CODE W/ WASHINGTON STATE AMENDMENTS 2012 INTERNATIONAL FIRE CODE 2012 INTERNATIONAL MECHANICAL CODE 2012 INTERNATIONAL PLUMBING CODE W/ WASHINGTON STATE AMENDMENTS 2012 NREC BARRIER FREE - INTERNATIONAL CODE COUNCIL - ANSI STANDARD 117.1 ARCHITECTURA1 SYMBn1 S BUILDING MARKER BOARD J SECTION DOOR SYMBOL SYMBOL n DOOR NUMBER WALL SECTION IIIILLLLIIIIYYYY1111 WINDOW, RELITE SYMBOL 48 AND SKYLIGHT DETAIL TYPE SYMBOL SYMBOL WALL TYPE A.B. SYMBOL V x tai INTERIOR MINIMUM OR MINUTE ELEVATION LOUVER SYMBOL SYMBOL ENTRY ROOM NAME RE [SION ROOM NUMBER SYMBOL rt Z E� BUBBLE NOTE GRID NE GRID L I NO. SCHFDIJI F OF DRAWINGS GENERAL NO i TO SCALE A'00 PROJECT INFORMATION SHEET BITUMINOUS CIVIL ON CENTER T7.0 OVERALL SITE IMPROVEMENTS COVER SHEET BUILDING C 1.0 DEMOLITION AND EROSION CONTROL PLAN OWNER FURNISH C 1.1 DEMOLITION AND EROSION CONTROL NOTES AND DETAILS C2.0 SURFACING AND GRADING AND DRAINAGE PLAN C2.1 SURFACING AND GRADING AND DRAINAGE DETAILS C2.2 GRADING AND DRAINAGE NOTES BM. ARCHITECTURAL OFOI A7.00 ARCHITECTURAL SITE PLAN BO. A2A0 BUILDING FLOOR PLAN. ROOF PLAN AND DETAILS OH STRUCTURAL E J S7 AO GENERAL NOTES PAV. 51.01 GENERAL NOTES CL NG. 52.00 FOUNDATION PLAN PCM 53.00 FOUNDATION DETAILS COL. ELECTRICAL E0.01 ELECTRICAL LEGEND. DETAILS, GENERAL NOTES, LIGHTING FIXTURE SCHEDULE EI.O ELECTRICAL SITE PLAN CONCRETE E2.00 PLAYSHED ELECTRICAL PLAN, ONE-UNE DIAGRAM, PANEL SCHEDULE, DETAILS ARRRE NOTE'. ADDITIONAL ABBREVIATIONS ARE INCLUDED THROUGHOUT DRAWING SET 0` AT MB MARKER BOARD Cj CENTERLINE MECH. MECHANICAL 'O DIAMETER OR ROUND MOD MEDIUM DENSITY k POUND RNUMBER ROOF AREA: 3,612 S.F OVERLAY A.B. ANCHOR BOLTS MIN. MINIMUM OR MINUTE ACP ACOUSTICAL CEILING M METAL F 253 - 922-0896 PANEL NIC NOT IN CONTRACT A.F.F. ABOVE FINISH FLOOR NO. NUMBER BD. BOARD NTS NO i TO SCALE BR. BITUMINOUS OC ON CENTER BLDG. BUILDING OFCI OWNER FURNISH BLKG. BLOCKING I CONTRACTOR INSTALL BM. BEAM OFOI OWNER FURNISH. OWNER INSTALL BO. BOTTOM OF OH OPPOSITE HAND E J CONTROL JOINT PAV. PAVEMENT CL NG. CEILING PCM PROJECTOR CEILING COL. COLUMN MOUNT CONIC. CONCRETE PIM PROGRAM INFORMATION CONST. CONSTRUCTION MANUAL CONT. CONTINUOUS P.L. PROPERTY LINE CPT. CARPET PLAM PLASTIC LAMINATE CT CERAMIC TILE PLYWD. PLYWOOD DBL. DOUBLE PR, PAIR DOE DOOR OPERATOR PT PAINT POST PW PLYWOOD DP DEEP RB RUBBER BASE DS DOWNSPOUT RECPT. RECEPTACLE EW EYEWASH STATION READ. REQUIRED (E) EXISTING REV. REVISIONS ETC. ETCETERA S.C. SOLID CORE EA EACH SCHED. SCHEDULE Ei EXPANSION JOINT SECT. SECTION ELECT. ELECTRICAL SF SQUAREFOOT ELEV ELEVATION SG SAFETY GLAZING EO EDGE OF E.O. Sim SIMILAR EQ EQUAL SPEC. SPECIFICATION EQUIP EQUIPMENT SQ. SQUARE EXH EXHAUST S.S. STAINLESS STEEL EXT EXTERIOR STD STANDARD FA FIRE ALARM STL STEEL FNDN FOUNDATION STOR. STORAGE FEE FINISHED END PANEL STRUCT. STRUCTURAL OR STRUCTURE FIN FINISH SV SHEET VINYL F.F. FINISH FLOOR TB TACKBOARD FSS FOLD DOWN SHOWER SEAT Te,G TONGUE 3 GROOVE FT FOOT OR FEET THK. THICK FX FIRE EXTINGUISHER T.O. TOP OF GA GAUGE T.S. TUBE STEEL GALV. GALVANIZED T.W.S. TACKABLE WALL SURFACE GWB GYPSUM WALLBOARD (ARCH.) HACK HUNG ACOUSTICAL TYP TYPICAL CEILING PANELS U URINAL H.M. HOLLOW METAL U.N.O. UNLESS NOTED OTHERWISE H HEIGHT OR HIGH VERT. VERTICAL HORIZ. HORIZONTAL VP VENEER PLASTER I.D. INSIDE DV.METER VWC VINYL WALL COVERING IN INCHES W WIDEORWIDTH INSUL. INSULATION W/ WITH ENT. INTERIOR WB WHITE BOARD/ MARKER A JOINT BOARD 1ST. JOIST WD WOOD LAM, LAMINATED W.G. WIRE GROMMETS LAV. LAVATORY W.M. WALL MAT LBB LINOLEUM BULLETIN BOARD W/O WITHOUT LF LINEAL FEET WST WAINSCOT MAX MAXIMUM WWf WELDED WIRE FABRIC �F. Chapter 3 - Occupancy Type Section 303.4 - Assembly (A -3 recreotionl Chapter 6 -Type of Construction Table 601 -Type 2N Inoncombusfoble) Chapter 5 - Building Limitations Table 503 - Type 2N movimum construction is 9.500 S.F. at 2 stories > 3.841 S.F. at 1 story (proposed play shed) Chapter 10- Occupant Load Calculation • Table 1004.1.2 fine closest use Was exercise space of 50 S.F. / person. 3,841 S.F. / 50 S.F. per occupant equal 77 occupants. • Section 1015.2 - The play shed Is on exterior non - conditioned. no exterior wal5 structure. It has unobstructed exiling from the structure. Chapter 9 - Eke Protection Systems • Section 903.2.1.3 Group A -3 occupancy - The play shed is less than 12,000 square feet and has an occupant load of less than 300. A Tire sprinkler system is not required. • Section 907.2.1 Group A occupancy - The play shed has an occupant food of less thon 300 occupants. A fie alarm System Is not required. Differed Submittal: The metal building play shed manufacturer 5hol be submitting Engineered Drawings and Calculations performed by a Structural Engineer licen in Washington State, PROPERLY LINE f STRUCTURAL ENGINEER 1029'x" 1, 1 z OWNER 1 PCS STRUCTURAL SOLUTIONS SETTS & HILL ENGINEERS TACOMEA, ERICKSON McGOVERN. PLLC T984211 NEW PLAYSHED - _ ACOMA, WASHINGTONU994244 TACOMA, WASHINGTON 98402 ROOF AREA: 3,612 S.F TACOMA, WASHINGTON YELLM WASHINGTON 98597 SF/ oc (253) 383 -2797 (253) 474 -9449 P: (253) 531 -0206 - 723 oc F 253 - 922-0896 (253) 383 -1557 (FAX) (253) 474-0153 F: (253) 531 -9197 F 360 - 458 -6434 - F • CONTACT: WES NEELEY CONTACT: MARTY MERRIOTT CONTACT: RAY MOW, AIA PROPERTY LINE ................ I PROPERTY LINE 54 1 , I I \ I ?? 1 1 MILLPOND EIEMEMARY SCHOOL PROPERTY LINE "ED A� OVERALL SIDE PLAN NQR„ SCALE:I "= 200' -0" 1 �i /1 Z e w �3 >o OE E O u °u a 052 U m • E Z � O U_ 1- W W N Z O Q O LL Z i— W O Ly- EL 0 W N Q IL J O O U QN ~ O LU W O C � U h LLJ J } W 'E 0 Z) z 00 U J } W79 5 REGISTERED AR CT YMOND C. TE OF WASHINGTON Project: 2015 -20 Drown: JTM BIDSET 06/29/15 ShPP. ". ELECTRICAL ENGINEER STRUCTURAL ENGINEER CIVIL ENGINEER ARCHITECT OWNER BCE ENGINEERS, INC. 6021 PCS STRUCTURAL SOLUTIONS SETTS & HILL ENGINEERS TACOMEA, ERICKSON McGOVERN. PLLC T984211 YELM COMMUNITY SCHOOLS No.2 A0.00 ACOMA, WASHINGTONU994244 TACOMA, WASHINGTON 98402 WASHINGTON 98409 TACOMA, WASHINGTON YELLM WASHINGTON 98597 P 253 - 922 -0446 (253) 383 -2797 (253) 474 -9449 P: (253) 531 -0206 P 360 - 458 -6128 F 253 - 922-0896 (253) 383 -1557 (FAX) (253) 474-0153 F: (253) 531 -9197 F 360 - 458 -6434 CONTACT: CARRIE TAYLOR CONTACT: WES NEELEY CONTACT: MARTY MERRIOTT CONTACT: RAY MOW, AIA CONTACTS: CHRIS HANSEN YELM COMMUNITY SCHOOLS APPROVED FOR CONSTRUCTION BY: DATE: Director of Public Works APPROVAL EXPIRES: MILL POND ELEMENTARY SCHOOL VICINITY MAP SCALE: N.T.S. PROJECT NFORMATION- PROJECT STE PARCEL NUMBERS 21725140100 PROJECT SITE AREA: 0.16 ACRES (6,802 SF) TOTAL NEW AND REPLACED ON -SITE IMPERVIOUS SURFACE: 016 ACRES (6,802 SF) SCOPE OF WORK: PLANS FOR THE DEVELOPMENT OF THE NEW PLAY SHED. SITE ADDRESS: 909 WILL ROAD S.E. YELM, WASHINGTON 98597 TOTAL CUT/FILL: <50 CY I r1-- - PREPARED FOR: PLAY SHED ERICKSON • MCGOVERN Erickson McGovern P.L.L.C. 101 E 26th Street, Suite 300, Tacoma, WA 98421 CONTACT: RAY MOW, AIA, WAMOA PREPARED BY S I TT S & HILL ENGINEERS, INC. CIVIL ■ STRUCTURAL ■ SURVEYING 4815 CENTER STREET. TACOMA, WA. 98409 (253) 4/4 -9449 FAX (253) 474 -0153 CONTACT: MARTY MERRIOTT, PROJECT MANAGER �n y / / LIMITS OF WORK � NORTH s \ - EXISTING SCHOOL BUILDING A . PLAY SHED � ` 1 \ 'it J1I 19 It EXISTING SCHOOL BUILDING Ij , OVERALL SITE PLAN NORTH INDEX OF DRAWINGS ":_0 OVERALL SITE IMPROVEMENTS COVER SHEET C1.0 DEMCUTION AND EROSION CONTROL PLAN GIA DEMOUTION AND EROSION CONTROL NOTES AND DETAILS C2.0 SLRFACJNG AND GRADING AND DRAINAGE PLAN C2.1 SURFACING AND GRADING AND DRAINAGE DETAILS C2.2 GRADING AND DRAINAGE NOTES SURVEY NOTES HORIZONTAL DATUM WASHINGTON STATE PLANE COORDINATE SYSTEM, SOUTH ZONE, HAD 83/2011 VERTICAL DATUM NAVD 88 ESTABLISHED VERTICAL VALUES THROUGH GPS MEASUREMENTS BASED ON NGS PUBLISHED GECID2012A WITH THE NAD83 (2011) EUJPSDID REFERENCE FRAME SITE TBM: NAG NAIL AT BASE OF STARS ON WEST SIDE OF SITE ELEVATION = 370.06 NOTES 1. EQUIPMENT USED: TOPCON QS ROBOTIC TOTAL STATION 2. THIS SURVEY WAS PERFORMED BY FIELD TRAVERSE WITH THE FINAL RESULTS MEETING OR EXCEEDING THE CURRENT TRAVERSE STANDARDS CONTAINED IN W.P.C. 332 -130 -090. ALL MEASUREMENTS WERE MADE WITH A TOPCON OS ROBOTIC TOTAL STA70N IN ACCORDANCE WITH THE EQUIPMENT MANUFACTURER'S SPECIFICATIONS 3. FIELD WORK PERFORMED IN MAY 2015. 4. UTILITIES AS SHOWN HEREON ARE BASED ON FIELD SURVEY OBSERVATION OF UTUTY LOCATE SERVICES PERFORMED BY MOUNTAIN VIEW LOCATING SERVICES, INC. IN MAY 2015 FOR THIS SURVEY. UMITIES OTHER THAN SHOWN MAY EXIST ON THE SITE. THE SURVEYOR DOES NOT WARRANT THAT THE UNDERGROUND UTIUTIES SHOWN ARE IN THE EXACT LOCATION INDICATED. THE SURVEYOR DOES CERTIFY THAT THEY ARE SHOWN AS ACCURATELY AS POSSIBLE FROM FIELD SURVEY AND PAINTED UTILITY LOCATE LINES COLLECTION AND DEPICTION OF EXISTING SUBSURFACE UTILITY DATA IS CONSISTENT NTH QUALITY LEVEL (B) OF THE ASCE STANDARD GUIDELINES 38 -02. LEGAL DESCRIPTION PARCEL 8 OF CITY OF YELM BOUNDARY UNE ADJUSTMENT NUMBER 8144 FRED UNDER AUDITOR'S FEE NUMBER 9505220009, RECORDS OF THURSTON COUNTY, WASHINGTON, BEING A PORTION OF THE N.E. X OF SECTION 25, TOWNSHIP 17 NORTH, RANGE 1 EAST OF THE WILLAMETTE MERIDIAN SITTS & HILL ENGINEERS, INC. CIVIL • STRUCTURAL • SURVEYING 4815 CENTER S1REEr TACOMA. WA 98409 PHONE: (253) 474 -9449 Project Na: 18538 Project Mgr.: M.LM. P,Dj Erglit— K.H. I Pro} Draft'. J.M.W. Z w > 0 0 U - w Z 0 V) U w H w w S N w O J Z ELI w O w 1— Q IY LU X w N Q J O_ J 0 0 U N (V Z Q Z ° w ° w N U J t LU D � Z E 0 E O CL U J_ E E >_ xP� ^Z• ��^ �32DNAL EKG 01/81/15 Project: 2015 -20 Drawn: JMW BID SET 06/29/15 Sheet T1.0 h� i� �N M5' NAIL r : �P t 41: .90831.335? 36623. ELEY': 366 - %n % � p �{'x /a 2/ o.. Pvc r PE ; j r��.g:.. op v APPROVED FOR CONSTRUCTION BY: DATE: Director of Public Works APPROVAL EXPIRES: LEA % / / FEATURES, / r"+� s �,ro /5D CATCH BASIN PROTECTION, PER DETAIL D7 C7.1 // Q.x so,/ SILT FENCE (NEW) S ORk -ATC, BASIN \ \,6,y- •§SN9v "- jA - / N// DEMOLITION UNIT OF WORK I 363.9 F LPP E 60- ///' / );':R / I "36M1 69 6 PVC S � �55ti� - e rL' S SAWCUT LINE _353. EXISTING STORM DRAIN .5 `J FENCE END 4 \ v / — ' 2 EXISTING WATER MAIN CONC. RETA'NINC 'A'ALL i �'� �-� ! CONCRETE \�� 56H.3.: e c (T> �� EDGE " \\ c G /�� - ` c c EXISTING SEPTIC LINE (RECORD LOCATION) �'�� �.-' - - x'..•F - / CJRBAENO� \ \a i' PAVEMENT REMOVAL _ \ / c. TYPE 1 CATCH BASIN- DEMOLISFf/ , ,� 1 // ,. . OwIINE \J FRA19EIAND GRATE / /y '� C ° KEY NOTES / SEE SHEET CZAY �i C ` ,• d' v -BUILDING OVERHANG LINE. Oj DEMOLISH . AS NOTED PH/ (TYP.) e ,eY' / i ,'A�SPHALT�WEOGE CURB- 2 CHAINUNK ° c 0 PROTECT AS NOTED START' �fiNGE'START � i��S�' i \ 'E z• (( a { Q I I g c / 3O PROTECT EXISTING UTILITIES AS NOTED // `y=s TYPE 2 CATCH: BASN - DEMOLISH SAWCUT ASPHALT /CONCRETE �SOLIG u0 AND FRAME SEE SHEET l C2.Q SALVAGE AS NOTED, COORDINATE WITH OWNER /ARCHITECT W TER MAIN >, �6 2 \ \\ -/ �y - `<'J 'r d C�!II* - ��ry a \a DEFINMONS CON \\ 1 \1 > 031 LAND CRETE £ C �' ° ' l� q/ C c \ n DEMOLISH, CAREFULLY REMOVE EXISTING ITEM AS INDICATED AND AND \ \\ .� \Y. ie, I ! .-� 0 LEGALLY DISPOSE OF SAME OFFSITE. CURBING PLAYGROUND < I cam. i '1' ' SEE NOTE POLL c .! REUSE/RELOCATE, CAREFULLY REMOVE EXIS71NG ITEM, INTACT, AS a \ 1 4 /C1.0 W 1 G ?'' \): - INDICATED, TEMPORARILY STORE (IF NECESSARY) AND PROTECT (FOR \ \\\ �� :\ \\\ \ \ �.- \< •, \ �I� \ eC e,.43� MAIN BUILDING REINSTALLATION, INTACT, AS INDICATED). `WAITER MAltr BASKETBALL - I, I 1 ' CAREFULLY REMOVE EXISTING ITEM INTACT AS INDICATED MA,: NA; \ \, \ \ ( \ HOOP ��- c. j <. A B b SALVAIL' N. 590?6' ��1 \ \ \. °" - `I,, \ AND DELIVER TO OWNER /OTHER, INTACT, AS INSTRUCTED. E l,123I5.9920 \' \\ \\ - G °£\ ,! J \ @.A: 370:06 \ \ \ \\ \ - 1 i e\ PROTECT: LEAVE EXISTING ITEM INPLACE, INTACT, AS INDICATED, AND /-SEE NOTE �� 1 O 4 3r, \ 4 /C1 O `\ ° ql PROTECT FROM DAMAGE. THIS IS PART OF ATISDNG-TPOSE. AND � � - � '�. C �. IS SPECIFICALLY NOTED ONLY FOR CLARIFICATION PURPOSES. \ IT \ X369 \9� \ 0 ice' PLAYGROUNr _ _ \\ o C ° I \ NOTE: THE CONTRACTOR SHALL VISIT TIE SITE TO PERFORM A THOROUGH WALK THROUGH \. _ �,v POLE - - \ I � a 1p� `- TO EXAMINE ALL ITEMS 70 BE bEM0U5HE0' 'REUSE/RELOCATED'. '$ALVAGEC' OR FLOWUNE / \ \ \\ \ °. "SAVED" ALL ITEMS SHALL BE INCLUDED IN THE CONTRACTORS SCOPE OF WORK AND BID. SANG \ \ \ I \\ \ \ SANITARY SEWER MANHOLE \ '1. \ K\i vv v va 2 369.39x M xss� �( a ° t wo GENERAL NOTES SEPTIC, 11, MOAN �� SANITARS SEWEf IAANP \ C 1 b - 1. EXISTING SITE FEATURES AND UTILITIES ARE SHOWN BASED UPON TOPOGRAPHIC SURVEY �i NIA SAWCUT LINE - RIM=. PREPARED f \� \ n \ PREPARED BY SIT TS AND HILL ENGNEERS, INC, AND AS BUILT PLANS AN) INFORMATION G' CHAIN LINK FENCE \ n \ e (T.P.) \ \ \ \ 55 DURING CONSTRUCTION L; SEfll �_ c c \ PROVIDED Bt' YELM SCHOOL DISTRICT NOT ALL SITE FEATURES AND UTIL1T1' SERVICES HAVE \,,1 i.(9 I i g, h x s BEEN LOCATED OR SHOWN. THE CONTRACTOR SHALL LOCATE, BY TRADRIONAL METHODS, _ I \ c GROUND PENETRATING RADAR (GPR) OR OTHER, OR HAVE LOCATED, ALL UNDERGROUND 8 1 4 "` \ ti \ C \' UTILITIES PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL CONTACT ALL UTWTY FINAL SAWCUT UNE - L,"' SANITARY SEW:R MANHOLE -- y,. cf \ 1 \\ \ JUST PRIOR TO PAVING x RIM =;y •q ��,-,� C 4N x'� \ 1 \ \\ ° ° \ COMPANIES AND HAVE THEIR LOCATION MARKED ON THE GROUND PRIOR TO 1 :`00- SEPTIC JD * CONSTRUCTION. THE CONTRACTOR WILL PROTECT. OR IMMEDIATELY REPAIR, ANY DAMAGED yi'- / _ ° C \ °1 \\\ \ UTIUTY (UTILRIES INCLUDING, BUT NOT UNITED TO: SANITARY SEWER. TELEPHONE/D4TA• A, ♦6 ` /` BURIED POWER, WATER, STORM SYSTEMS, UNDER DRAIN SYSTEMS, GAS), 'DISCOVERED' ON -T; �• / 9a'1 ° '� THIS PROJECT WTHOUT ADDITIONAL COSTS. 1 / � ��� c� < 2. THE CONTRACTOR SHALL COORDINATE ALL UTILITY SHUTOFFS WITH OWNER, ARCHITECT. t / I 1 `w' J/ ` \ % SANITARY SEWER AIfANH� \ CITY OF YEUA AND ALL OTHER UTILITY PURVEYORS. ! BRICK WALL_ 370.07 - - ,-SO` RIM-35S 59. ...,..C. RET.UNlNG(TYP )�� SEPTIC LE' - n ° \\ 3. CONTRACTOR TO REMOVE ALL PROPOSED AND EXISTING EROSION AND SEDIMENT CONTROL 37GaA 3'G �, l DEVICES AT COMPLETION OF WORK. 4�. C,! `SA•J !TA SEWER MANHOLE - \ 4. CONTRACTOR TO CAREFULLY POTHOLE EXSTING UTILITY (WITHOUT DAMAGING) BY MEANS RIM 369.3G \ OF SMALL EQUIPMENT, VACTOR TRUCK, OR OTHER MEANS TO DETERMINE EXACT 7 j )•F 3 w �� 'C \ >o �= - - J RI Pnr Lip HOROZONTAL AND VERTICAL LOCATION. CONTRACTOR TO INITIALLY LOCATE WITH GPR OR OTHER MEANS. UPON LOCATING, THE CONTRACTOR SHALL DETERMINE IF THE PROPOSED / tt" FOOTINGS WILL EFFECT THE EXISTING URUTY BY I75 ZONE OF INFLUENCE. SEE \_ ' \ "moo, DRINKING FOUNTAIN f3 a " \S ` < S7RUCNRAL SECTION 1/53.00. IF THE ZONE OF INFLUENCE AT THE BOTTOM OF THE I ! • Ot j T FOOTING INTERSECTS THE EXISTING PIPE AT OR ABOVE THE BOTTOM OF THE PIPE, t N t if I i -STORM CATO, BASIN j \ CONTACT THE ARCHITECT PRIOR TO PROCEEDING. f ) + /j I RIN= =363.89 ' ° THE BURIED UTIUTIES ON THIS PROJECT, EXCEPT FOR SANITARY SEWER, 10'CPP N ARE SHOWN IN THEIR APPROXIMATE LOCATION WHERE KNOWN. OTHER 5. SEE C1.1 FOR ADDITION DEMOLITION AND EROSION CONTROL NOTES AS REWIRED. t I iU I 363.29, 6 °PVC E \` EXISTING BURIED UTIUTIES MAY NOT BE SHOWN ON THESE PLANS. THE CONTRACTOR SHALL CONTACT ALL UTILITY COMPANIES AND HAVE THEIR IE =36' 99, 1C 'CPF` S 7 6. ALL DEMOLISHED MATERIALS AND EXCAVATION SPOILS SHALL BE IMMEDIATELY HAULED .ADDER 9, \ MAIN BUILDING LOCATION MARKED OI THE GROUND PRIOR TO CONSTRUCTION. THE / OFF -SITE TO AN APPROVED LOCATION OR MAY BE TEMPORARILY STOCKPILED ON-SITE `'0 CONTRACTOR WILL PROTECT, OR IMMEDIATELY REPAIR. ANY DAMAGED ONLY IF COORDINATED AND APPROVED WITH THE SCHOOL DISTRICT AND ARCHITECT PRIOR It l !j j y I qi \\ UOPN'TY 'DISCOVERED' ON THIS PROJECT WITHOUT ADDITIONAL COSTS. TO CONSTRUCTION. m r x Call 2 Working Days Before You Dig SITTS & HILL 1- 800 - 424 -5555 ENGINEERS, INC. SAND G5 \ Utilities Underground Location Center " CIVIL - STRUCTURAL - SURVEYING NORTlI 4815 CENTER STREET TACOMA. WA. 98409 PHONE: (357) 474 -9449 DEMOLITION AND EROSION CONTROL PLAN HoazoNTU SCALE: r =1D' 10 0 10 20 Project Na: 18538 Project Mgr.: N.L.N. SCALE: 1 " =10' I Pre} Engineer: K.H. Proj. Drafter: J.N.W. LLU < > ° o � O 0 52 0 W Z J CL J O W Z O U Z O N O W LU 0 Z Q O O W 0 0 LU Q CL O O N CV 0 7-0 W O _CU J � LU •E 0Z) Z p EL UCC J_C E A. HA �4nC Re'ctsrcnE �,t�, , SS /ONAL EPG Y' Project: 2015 -20 Drawn: JMw BID SET 06/29/15 Sheen Cl .0 STANDARD EROSION CONTROL NOTES 1. ON -SITE EROSION MEASURES SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. ANY PROBLEMS OCCURRING BEFORE FINAL ACCEPTANCE OF THE STORM SYSTEM BY THE MUNICIPALITY SHALL BE CORRECTED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. I IN CASE EROSION OR SEDIMENTATION OCCURS TO ADJACENT PROPERTY, ALL CONSTRUCTION WORK WITHIN THE DEVELOPMENT THAT WALL AGGRAVATE THE SITUATION MUST CEASE AND THE CONTRACTOR SHALL IMMEDIATELY COMMENCE RESTORATION OR MITIGATION METHODS. RESTORATION ACTIVITY WILL CONTINUE UNTIL SUCH TIME AS THE PROBLEM IS RECTIFIED. 3. ALL EROSION AND SEDIMENTATION CONTROL DEVICES SHOWN ON THIS DRAWING SHALL BE INSTALLED PRIOR TO OR AS THE FIRST STAGE OF SITE PREPARATION. 4. SHOULD THE TEMPORARY EROSION AND SEDIMENTATION CONTROL MEASURES AS SHOWN ON THIS DRAWING NOT PROVE ADEQUATE TO CONTROL EROSION AND SEDIMENTATION, THE CONTRACTOR SHALL INSTALL ADDITIONAL FACILITIES/EMERGENCY MEASURES AS NECESSARY (AT NO ADDITIONAL COST TO THE OMER) TO PROTECT ADJACENT PROPERTIES, SENSITIVE AREAS, NATURAL WATER COURSES AND /OR STORM DRAINAGE SYSTEMS. THE ENGINEER OR MASON COUNTY OR STATE INSPECTORS CAN RESERVE THE RIGHT TO REQUEST ADDITIONAL TESL MEASURES BE INSTALLED ANYTIME DURING CONSTRUCTION AS NEEDED (AT NO ADDITIONAL COST TO THE OWNER). 5. IN ANY AREA WHICH HAS BEEN STRIPPED OF VEGETATION OR EXPERIENCED LAND DISTURBING ACTIVITIES AND WHERE NO FURTHER WORK IS ANTICIPATED FOR A PERIOD EXCEEDING THE LISTED CRITERIA, ALL DISTURBED AREAS MUST BE IMMEDIATELY STABILIZED WITH MULCHING, GRASS PLANTING OR OTHER APPROVED EROSION CONTROL TREATMENT APPLICABLE TO THE TIME OF YEAR IN QUESTION. CRASS SEEDING ALONE WALL BE ACCEPTABLE ONLY DURING THE MONTHS OF APRIL THROUGH SEPTEMBER INCLUSIVE. SEEDING MAY PROCEED, HOWEVER, WHENEVER IT IS THE INTEREST OF THE CONTRACTOR, BUT MUST BE AUGMENTED WITH MULCHING. 6. THE PROJECT SURVEYOR 'AWLL BE RESPONSIBLE FOR FIELD LOCATING THE CLEARING LIMITS AND ESTABLISHING THOSE BOUNDARIES WITH BRIGHT COLORED FLAGGING. THE CONTRACTOR SHALL CLEAR TO THE UNITS AS ESTABUSHED ON THIS PUN AND AS FLAGGED IN THE FIELD. 7. THE COUNTY SHALL BE RESPONSIBLE FOR THE INSPECTION AND ACCEPTANCE OF ALL CLEARING AND GRADING WORK AND EROSION AND SEDIMENTATION CONTROL FACILITIES. THE CONTRACTOR SHALL NOTIFY THE COUNTY FORTY -EIGHT HOURS IN ADVANCE OF EACH REQUIRED EROSION AND SEDIMENT CONTROL INSPECTION. INSPECTION NO. 1 - INSTALLATION OF EROSION CONTROL FACIUTIES/PRIOR TO CLEARING. INSPECTION NO. 2 - COMPLETION OF CLEARING. INSPECTION NO. 3 - UPON COMPLETION OF EXCAVATION FILLING AND EARTHWORK. INSPECTION NO. 4 - COMPLETION OF PROJECT. INSPECTION NO. 5 - AS NEEDED TO DETERMINE COMPUANCE WITH APPROVED PLANS AND /OR SPECIFICATIONS. (DOES NOT REQUIRE ADVANCE NOTICE) B. ALL WORK ASSOCIATED WITH STABILIZING THE DISTURBED AREAS SHALL BE IN ACCORDANCE WITH THE 2005 DOE STORMWATER MANAGEMENT MANUAL FOR WESTERN WASHINGTON. 9. ALL NECESSARY FACILITIES SHALL HE MAINTAINED ON SITE TO PREVENT DEBRIS, DUST AND MUD FROM ACCUMULATING ON THE PUBLIC RIGHT-OF-WAY. CB PROTECTION NOTES 1. CATCH BASIN INSERTS SHALL BE PROVIDED IN THE CATCH BASINS NOTED ON THE PLANS. 2. AT ALL PROPOSED CATCH BASINS, CATCH BASIN PROTECTION SHALL BE INSTALLED IMMEDIATELY UPON CATCH BASIN INSTALLATION AND SHALL REMAIN UNTIL FINAL SITE STABILIZATION. 3. CATCH BASIN INSERT SHALL BE STREAMGUARD SEDIMENT CATCH BASIN INSERT x3003, ADVANCED ENVIRONMENTAL SOLUTIONS STREAM SENTRY DIRT TRAP, OR APPROVED EQUAL. 4. CATCH BASIN INSERTS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. S. CATCH BASIN INSERTS WALL BE REMOVED FOLLOWING COMPLETION OF CONSTRUCTION AND STABILIZATION OF ALL CLEARED AREAS. CATCH BASIN GRATE PLACED­- OVER INSTALL IN SERE I , OVERFLOW BYPASS RETRIEVAL STRAP (INSTALL THROUGH CRATE) CATCH BASIN INSERT ADAPTER SKIRT 'L MANUFACTURED SEGMENT ACCUMULATION `,. j CATCH BASIN INSERT CS PROTECTION DETAIL J/ SCALE: N.T.S. PLASTIC COVERING NOTES (SEE NOTE 6/C1.0) 1. PLASTIC SHEETING SHALL HAVE A MINIMUM THICKNESS OF 6 MILS AND SHALL MEET THE REQUIREMENTS OF THE STATE STANDARD SPECIFICATIONS SECTION 9 -14.5. 2. COVERING SHALL BE INSTALLED AND MAINTAINED TIGHTLY IN PLACE BY USING SANDBAGS OR TIRES ON ROPES WITH A MAXIMUM 10 -FOOT GRID SPACING IN ALL DIRECTIONS. ALL SEAMS SHALL BE TAPED OR WEIGHTED DOWN FULL LENGTH AND THERE SHAH BE AT LEAST A 12 -INCH OVERLAP OF ALL SEAMS. 3. CLEAR PLASTIC COVERING SHALL BE INSTALLED IMMEDIATELY ON AREAS SEEDED BETWEEN NOVEMBER I AND MARCH 31 AND REMAIN UNTIL VEGETATION IS FIRMLY ESTABLISHED. 4. MIEN THE COVERING IS USED ON UN- SEEDED SLOPES IT SHALL BE KEPT IN PLACE UNTIL THE NEXT SEEDING PERIOD. 5. PLASTIC COVERING SHEETS SHALL BE BURIED TWO FEET AT THE TOP OF SLOPES IN ORDER TO PREVENT SURFACE WATER FLOW BENEATH SHEETS 6. PROPER MAINTENANCE INCLUDES REGULAR CHECKS FOR RIPS AND DISLODGED ENDS. DIV" C6 I I I Eel ZV Eel 1 *� 1. REMOVE ALL DELETERIOUS MATERIAL FOUND ON -SITE INCLUDING VEGETATION, SCRAP WOOD, TRASH, ETC. AND DISPOSE OF AT AN APPROVED OFF -SITE LOCATION. 2. AT ALL TIMES THE CONTRACTOR SMALL MAINTAIN SIGNS, BARRICADES, FENCING, OR OTHER MEASURES TO ENSURE CONTINUOUS PROTECTION OF THE PUBLIC AND TO PREVENT UNAUTHORIZED ENTRY TO THE CONSTRUCTION AREA. AT A MINIMUM FENCING SHALL BE 6.0 FEET HIGH. 3. PUBLIC SAFETY AND TRAFFIC CONTROL SHALL BE PROVIDED IN ACCORDANCE WITH CITY REQUIREMENTS. SAFE VEHICULAR AND PEDESTRIAN ACCESS SHALL BE PROVIDED AT ALL TIMES DURING CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL TRAFFIC CONTROL SIGNS 4. THE CONTRACTOR IS FINANCIALLY RESPONSIBLE FOR THE MAINTENANCE AND /OR REPAIR OF OFF -SITE AND ON -SITE PAVED SURFACES WHERE DAMAGE HAS BEEN SUSTAINED DUE TO THE DEVELOPMENT'S CONSTRUCTION TRAFFIC. 5. ALL CONCRETE, PAVEMENT, CURBS, SIDEWALKS AND RAMPS INDICATED TO BE REMOVED OR REPLACED SHALL BE REMOVED TO THE NEAREST EXPANSION JOINT AS IDENTIFIED DURING CONSTRUCTION. WHERE THIS IS NOT POSSIBLE DUE TO CONFLICTS OR ADJACENT DAMAGED CONCRETE / ASPHALT, THE CONTRACTOR SHALL MAKE A FULL PAVEMENT DEPTH SAWCUT AT THE PROPOSED JOINT IN SOUND PAVEMENT. PROPOSED CONCRETE / ASPHALT SHALL EXTEND TO THE SAWCUT EDGE AND BE APPROPRIATELY JOINED / SEALED. THE CONTRACTOR SHALL MAKE SAWCUTS AT EXISTING CONTRACTION JOINTS WHERE POSSIBLE POLLUTION PREVENTION NOTES 1. EQUIPMENT LUBRICATION AND FUELING OPERATIONS SHALL OCCUR AT THE DESIGNATED FUELING AREA OR AN APPROVED OFF -SITE LOCATION. 2. PREVENT OILS AND FUELS FROM ENTERING THE STORM DRAINAGE SYSTEM WITH PROPER CONTAINMENT DEVICES 3. ACCESS TO CONSTRUCTION 15 VIA ADJACENT EXISTING PAVED STREETS. SWEEP DIRT FROM PAVING DAILY OR AS NEEDED. THE INTENT IS TO PREVENT DIRT AND DEBRIS FROM VEHICLES AND EQUIPMENT FROM BEING DEPOSITED ON CITY STREET PAVEMENT. 1. EROSION CONTROL FACIUTIES SHALL BE INSPECTED AFTER EACH HEAVE RAINFALL EVENT AND REPAIRED OR REVISED FOR IMPROVED EFFECTIVENESS AS NECESSARY 2. DEBRIS TRACKED ONTO THE CITY ROAD(S) TO BE SWEPT UP PRIOR TO THE END OF EACH WORKING DAY. CARE MUST BE TAKEN TO KEEP DIRT OUT OF DRAINAGE STRUCTURES. 3. SEE 'INSPECTION SCHEDULE, THIS SHEET STOCKPILE NOTES (SEE NOTE 6 /C1.0) 1. STOCKPILES SHALL BE STABILIZED (WITH PLASTIC COVERING OR OTHER APPROVED DEVICE) DAILY BETWEEN OCTOBER 1 AND APRIL 30. 2. IN ANY SEASON, SEDIMENT LEACHING FROM STOCKPILES MUST BE PREVENTED. 3. TOPSOIL SHALL NOT BE PLACED WHILE IN A FROZEN OR MUDDY CONDITION, WHEN THE SUBGRADE IS EXCESSIVELY WET, OR WHEN CONDITIONS EXIST THAT MAY OTHERWISE BE DETRIMENTAL TO PROPER GRADING OR PROPOSED SODDING AND SEEDING 4. PREVIOUSLY ESTABLISHED GRADES ON THE AREAS TO RECEIVE TOPSOIL SHALL BE MAINTAINED ACCORDING TO THE APPROVED PLANS 10' TYR 10 TYP. \ a9 A > 0 / -- A OnF ISOMETRIC VIEW (J 1l PLASTIC COVERING DETAIL (sm NOTE e/c o) SCALE: N.T.S. INSPECTION, MONITORING, DOCUMENTATION AND REPORTING SCHEDULE 1. THE CONTRACTOR SHALL BE THE OPERATOR / DESIGNEE DR ESC LEAD OF THE SITE THROUGHOUT THE PROJECT CONSTRUCTION DURATION. EROSION AND SEDIMENT CONTROL (ESC) FAOUTIES SHALL NOT BE ALLOWED TO FALL INTO DISREPAIR. THE CONTRACTOR SHALL INSPECT ALL PROJECT FACILITIES IN ACCORDANCE W /DOE NPDES CONSTRUCTION STORMWATER POLLUTION REQUIREMENTS. 2. THE ESC LEAD SHALL IMPLEMENT THE ESC PLAN. IMPLEMENTATION SHALL INCLUDE BUT IS NOT LIMITED T0: INSTALLING, MAINTAINING, INSPECTING MONITORING, DOCUMENTING, REPORTING AND REPAIRING ALL TEMPDRARY EROSION AND SEDIMENT CONTROL BEST MANAGEMENT PRACTICES INCLUDED IN THE PLAN, SEDIMENT CONTROL MEASURES SHALL BE INSPECTED AT LEAST ONCE EVERY FIVE WORKING DAYS, EACH WORKING DAY DURING A RUNOFF PRODUCING RAIN EVENT, AND WITHIN 24 HOURS AFTER A RUNOFF PRODUCING RAIN EVENT. ALL PROJECT CONSTRUCTION STORMWATER DISCHARGES SHALL COMPLY W/DOE DISCHARGE REQUIREMENTS INSPECTION SCHEDULE 1. EROSION AND SEDIMENT CONTROL (ESC) FACILITIES SHALL NOT BE ALLOWED TO FALL INTO DISREPAIR. THE PROPONENT OR DESIGNATED ESC LEAD SHALL INSPECT FACUTIES DURING AND AFTER RAINFALL EVENTS TO ENSURE PROPER OPERATION. NEEDED REPAIRS SHALL BE MADE WETHIN 24 HOURS OR IMMEDIATELY AFTER AN INSPECTION, IF POSSIBLE 2. THE ESC LEAD SHALL IMPLEMENT THE ESC PLAN. IMPLEMENTATION SHALL INCLUDE BUT IS NOT LIMITED T0: INSTALLING, MAINTAINING, INSPECTING AND REPAIRING ALL TEMPORARY EROSION AND SEDIMENT CONTROL BEST MANAGEMENT PRACTICES INCLUDED IN THE PLAN. SEDIMENT CONTROL MEASURES SHALL BE INSPECTED AT LEAST ONCE EVERY FIVE WORKING DAYS, EACH WORKING DAY DURING A RUNOFF PRODUCING RAIN EVENT, AND WITHIN 24 HOURS AFTER A RUNOFF PRODUCING RAIN EVENT, SEASONAL LIMITATIONS ON CONSTRUCTION ACTIVITIES .. THE FOLLOWING SHALL RE ADHERED TO ON ALL CONSTRUCTION SITES WITH EROSIVE SOILS AND /OR A GRADIENT OF GREATER THAN TWO PERCENT FOR UNITING EXPOSED SOILS TO EROSIVE PROCESSES MAY 1ST TO SEPTEMBER 30TH (DRY SEASON) 1. THE CLEARING OF LAND, INCLUDING THE REMOVAL OF EXISTING VEGETATION OR OTHER GROUND COVER, MUST BE LIMITED TO ONLY AS MUCH LAND AREA AS CAN RECEIVE APPROPRIATE PROTECTIVE COVER OR RE OTHERWISE STABILIZED AFTER HAVING BEEN CLEARED OR OTHERWISE DISTURBED BY NO LATER THAN SEPTEMBER 30TH OF A GIVEN YEAR. UNLESS IMMEDIATE STABIUZATION IS SPECIFIED IN THE EROSION AND SEDIMENTATION CONTROL PLAN, ALL AREAS CLEARED OR OTHERWISE DISTURBED MUST BE APPROPRIATELY STABILIZED THROUGH THE USE OF MULCHING, NETTING, PLASTIC SHEETING, EROSION BLANKETS, FREE DRAINING MATERIALS, ETC..., BY SEPTEMBER 30TH. 2. UNLESS OTHERWISE APPROVED BY THE COUNTY, SETTING, FERTIUZING AND MULCHING OF CLEARED OR OTHERWISE DISTURBED AREAS SHALL BE PERFORMED DURING THE FOLLOWING PERIODS MARCH IST THROUGH MAY 15TH AND AUGUST 15TH THROUGH OCTOBER 1ST. SEEDING AFTER OCTOBER HST VALL BE DONE WHEN PHYSICAL COMPLETION OF THE PROJECT IS IMMINENT AND THE ENVIRONMENTAL CONDITIONS ARE CONDUCIVE TO SATISFACTORY GROWTH. IN THE EVENT THAT PROJECT STABILIZATION IS NOT POSSIBLE, AN ALTERNATIVE METHOD OF GROUND DOVER (SUCH AS MULCHING, NETTING, PLASTIC SHEETING, EROSION BLANKETS ETC...,) MUST BE INSTALLED BY NO LATER THAN SEPTEMBER 301H. 3. IN THE EVENT THAT CONSTRUCTION ACTIVITIES OR OTHER SITE DEVELOPMENT ACTIVITIES ARE DISCONTINUED FOR FOUR CONSECUTIVE DAYS OR MORE, THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE INSPECTION OF ALL EROSION AND SEGMENTATION CONTROL FACILITIES IMMEDIATELY AFTER STORM EVENTS AND AT LEAST ONCE EVERY WEEK, THE CONTRACTOR SHALL BE RESPONSIBLE TO THE MAINTENANCE AND REPAIR OF ALL EROSION AND SEDIMENTATION CONTROL FACIUTES. 4. THE CONTRACTOR SHALL PROVIDE MATERIALS ONSITE READILY AVAILABLE TO IMMEDIATELY STABILIZE DENUDED AREAS DURING PERIODS OF INCLEMENT WEATHER WHICH RESULT IN EROSION AND SEDIMENT TRANSPORT OFFSITE. 5. THE CONTRACTOR SHALL ENSURE THE PROPER CONTINUED FUNCTIONING OF THE ESC FACILITIES BY PROMPT CLEANING AND MAINTENANCE AFTER EACH EROSION AND SEDIMENT PRODUCING RAINFALL EVENT. STAKE AND SAND BAG (TYP,) �I' OVERLAP - ALL SEAMS TO BE TAPED OR WEIGHTED DOWN WITH SAND BAGS AT 10' CENTERS ALONG THE SEAM 2'xYx3' WOODEN STAKE I V OVERLAP Y SEC 110N hON -A OVERLAP DETAIL BAG APPROVED FOR CONSTRUCTION BY: DATE: Director of Public Works APPROVAL EXPIRES: OCTOBER 1ST TO APRIL 30TH (WET SEASON) 1. ON SITES WHERE UNINTERRUPTED CONSTRUCTION ACTIVITY IS IN PROGRESS, THE CLEARING OF LAND, INCLUDING THE REMOVAL OF EXISTING VEGETATION OR OTHER GROUND COVER, SHALL BE LIMITED TO ONLY AS MUCH LAND AREA AS CAN BE COVERED OR STABILIZED WITHIN 24 HOURS IN THE EVENT A MAJOR STORM IS PREDICTED AND /OR EROSION /SEDIMENT TRANSPORT OFFSITE IS OBSERVED. 2. ADDITIONALLY, ALL CLEARED OR DISTURBED AREAS WALL RECEIVE APPROPRIATE PROTECTIVE COVER OR BE OTHERWISE STABIUZED (SUCH AS MULCHING NETTING, PLASTIC SHEETING, EROSION BLANKETS, FREE DRAINING MATERIAL, ETC...,) WITHIN FIVE DAYS AFTER HAVING BEEN CLEARED OR OTHERWISE DISTURBED IF NOT BEING ACTIVELY WORKED. FILTER FABRIC FENCING, SEDIMENT TRAPS, SEDIMENT PONDS, ETC..., WALL NOT BE `HEWED AS ADEQUATE COVER IN AND OF THEMSELVES IN THE EVENT THAT ANY LAND AREA NOT BEING ACTIVELY WORKED REMAINS UNPROTECTED OR HAS NOT BEEN APPROPRIATELY STABILIZED FIVE DAYS AFTER HAVING BEEN CLEARED, ALL CONSTRUCTION ACTIVITY ON THE SITE, EXCEPT FOR APPROVED EROSION AND SEDIMENTATION CONTROL ACTIVITY, SHALL IMMEDIATELY CEASE UNTIL SUCH A TIME AS SAID LAND HAS BEEN APPROPRIATELY PROTECTED OR STABILIZED. 3. THE CONTRACTOR SHALL AT ALL TIMES HAVE AVAILABLE FOR THE PROJECT SUFFICIENT QUANTITIES OF PROTECTIVE COVERING MATERIALS TO IMMEDIATELY STABIUZE ALL DISTURBED AREAS IN CASE THE PROJECT ENGINEER OR COUNTY DIRECTS THEM TO COVER DUE TO OBSERVED MIGRATION OF SOILS OR INCLEMENT WEATHER. 1� �L 2'.2'x3' -0' WOODEN STAKE. SPACED EVERY SEDIMENT TRAPPING �1s 4' -0' O.C. (TYP.) rAREA (TYP.) SEE WATTLE DETAIL STAGGER JOINTS (TYP.), SEE NOTE 2 1. WATTLES SHALL BE IN ACCORDANCE WITH WSOOT STRAW WATTLE STANDARD SPECIFICATION 9- 14.5(5). INSTALL WATTLES ALONG CONTOURS INSTALLATION SHALL TRENCH. BE IN ACCORDANCE WITH WSDOT STANDARD SEE NOTE 1 3' MIN. SPECIFICATION 8-01.3(10). 4' MAX. 2' WIN 2. SECURELY KNOT EACH END OF WATTLE, ABUT 5' MAX.. ADJACENT WATTLES TIGHTLY, END TD END, WITHOUT OVERLAPPING THE ENDS 3. PILOT HOLES MAY BE DRIVEN THROUGH THE WATTLES AND INTO THE SOIL WHEN CONDITIONS S I REQUIRE. 4. UVE STAKES MAY BE USED FOR PERMANENT INSTALLATION AND SHALL BE IN ACCORDANCE WITH WSDOT STANDARD SPECIFICATION 9-14.5(6). lSIDELETlL 5. WATTLES SHALL BE INSPECTED REGULARLY, AND IMMEDIATELY AFTER A RAINFALL PRODUCES RUNOFF, TO ENSURE THEY REMAIN THOROUGHLY ENTRENCHED AND IN CONTACT WTH THE SOL 6. PERFORM MAINTENANCE IN ACCORDANCE WITH WSDOT STANDARD SPECIFICATION B- 01.3(15). STRAW WATTLE DETAIL aF NEEDED FoR wAss sLOPD SCALE: N.T.S SITTS & HILL ENGINEERS, INC. CIVIL • STRUCTURAL • SURVEYING 4815 CENTER STREET TACOMA, WA. 98409 PHONE: (253) 474 -9449 P.w N9.: 165M Project Mgr.: M.L.M. Pro} Engineer. K.H. Proj. DrdI.. J.M.W. Z� LU =3 > id o E O uo /n Fa V U Z O V) o V_ _U I LU J_ Q W 0 0 Z Ln Q O Z O Z O U Z O N O w LU 0 Z Q Z O <O C W 0 LU V) Q J J O O U Cn N 0 Q Z O CW U L y U LU n J } W •� D Z O Q CL U E c- J_ } LAHA C '�, xecrs *.sawa �LS�, �`SSRONAL ENO o6RWAT6 Project: 201520 Drawn: JMW BID SET - 06/29/15 Sheet: 1 C 1 1 I 8 •m �::• PWc PIPE - rMAG NAIL. 'mY, i s 59083'..3355 1112471.3233 II IL + ELEV: 368.74' L 5,:! 0 `q \\ `l t1 Via'/ -•iA �" ,c: x RAISE RIM TO 37010 \ \ f , STORM CATC'r BASIN \ / RIM -367.9 % / REPLACE FRAME AND COVER WITH !,\ ` \ \ / I'c 364 5G 6 "PVC N \ J� INSTALL NEW TYPE 1 LOCKINr�G 24" FRAME AND SOLID LOCKING \ \ IE= 36385, 8"CPP E ) A2 FRAME AND HERRINGBONE; COVER SEE DETAIL D3/C21 �i / ;x ' ( IE-36469, 6 :nc 5 Bti;R 2. SEE DETAILS 01/C2.1 ANQ_02t2.1 / . 11 8.80 '� �'• / 366.80 366.021 _ � 1. so � 5x !/ /. CO3 _ # �dA3 EXISTING A'' a 1 CONC. RETAINING WALL i ` ` 9 ! C4 OS IE- 364.753 EXISTING 6" (M.i FIELD VERIFY v ° NE OI TSE1: 1 y4 CG GNNECT-WT �T� y6s 15 OF - 6STOR,4 x ?ve • 2%, i r� v FD._ / 5 0% (o 368.234 G / r ° < MA EXISTING . .d v a d o CROSSING R COS -1 / d.� y /.. v a. 17 LF 6" SDft -35 PVC O 2 $ JI �7 - /�% / i Y.� y.. C2 y w ,. `♦s ' 5(02 >' a 'BUILDING OVERHANG LINE. 4. sgFx, 5 LF 6•2'35 369.84 }5. _ ' - \ / 9 . 36 87 \ \ MA74N IS71NG c. o /� / /,,y PVC • t'✓' I j _ - s 32 LP 6" Sl1R- PVC 0 2% ARCHITECTURAL AND < \ '1 AA /�2i COI 'L X� • STRUCTURAL FOIE CONCRETE. p ,G SEE DETAIL D4/ 2.1 (TYP.) ,° 11 \ I� SLAB, AND:PI:AY SHED `a' 36 .89 a •'r' + `�, e ' b R AIN." 369.07 D uC H d 6 .y q �W Ot \ H? 44I 1 RIM= 3TC.09 (EXISJINGI _ qp7 - 38 . 1 I < - 4 - MAT ISTNC 11 °ays° - + ' TCH EXISTING ,E' == }6755 8 CPP El 1 a \ 370.1 I +�' f. w= ;3fi309'1"•" .lE%NiTNUj �x `.X-� IC20 k IDOE I \ ` I LAD :F - :. 5� 35821 V \ 11 r36¢.9Q, STIR -35 PVC N&Sf(PROPOSED) , ' `. N0.1E COORRii DRILL"SFOR'NI PIPE MAIN BUILDING NAG N 590 61 9190 ' \\ \ \\ �' C \1 \. t • - 1699 <`; ,. _ 4 \ \b<G. E: 11'2315.8924 ELEY, 370.05 MATCH 369 S ➢TUG \ •\ \ 370.00\ _ 368.734 Ak n\ \ \ •n yo * MATCH EXI PROTECT EXISTNG PLAYGROUND \ '• j7 - - �, -� EQUIPMENT TO REMAIN 1 \ 1 \ 'CROSSING OS - 369.53 PROTECT EXISTING 37 LF 6" SDR 35 \' \ -. _ PLAYGROUND EQUIPMENT' PVC O 2% TO REMAIN _ - -._ 'll •+ a CO2 �. 9. 1 \ � Cz' I 369.353 \ `, A2 ,r y\ MATCH EXIS G 36 \ C2' SANITARY SEWER MANHOLE MATCH EXITI81 G 3693P IM 368.95 I ° ` +\• e ` \ PROTECT EXISTING C SEPTIC LID q \ PLAYGROUND EQUIPMENT \\ 6' CHAIN LANK FENCE "`- i� . N TO REMAIN SAA,T.4Rr SEWER AMaN6 0 \ I \ 'IYP.)l \w \\ 65 •' \. 369.483 PROTECT EXISTING /� SEPTIC UC 1 1" 3> PLAYGROUND EQUIPMENT / v g�V ,4 MATCH EXISTING x}6`3 ' TO REMAIN x"�°j9' PROTECT EXISTING 1 G PLAYGROUND MATCH EXISTING SANITARY SEWER MANHCU �J a EQUIPMENT TO REMAIN RIM- 3591 SEPTIC LID EXISTING FIRE 3 -- HYDRANT � E6X9SIN\ \ `\ \ v c (P1 RIN 369. M�Ni0?E CONIC RETAININGNAL ITY SEWER BRICK WALL ' E f _ v v\ SEFVC ,I, / a7G.34 x'- .°. 'x" 0.4?, B .\ k, /� \ \ ` . "�, Q f , i ° a SAhI ARY SF1WR MANHOLE ` SEPTIC " - DRINKING FOUNTAIN 0. rl 5 ?ORH CATCH BASIN � \ RIM =36889 .99, \ IE 3'0 + 1C "CPP N %363.29, 6 "PVC E ` `. ILADDER9W 1C, CPS 5 1 MAIN BUILDING IlI I rl x9 +. M h 11 I 369.42 n I NORTH SURFACING, LAYOUT AND GRADING PLAN HORIZONTAL SCALE: 1 " =10• SCALE 0 0 10 20 APPROVED FOR CONSTRUCTION BY: DATE: Director of Public Works APPROVAL EXPIRES: LEGM PROPIDGED FEATIL11191- -M- ROOF DRAIN PIPE - SO - -- EXSTING STORM DRAM W EXISTING WATER MAW - SS - -- EXISTING SEPTIC ONE (RECORD LOCATION) - - - -- GRADE BREAK --- -� FLOW LINE • DOWNSPOUT (DS) SEE DETAIL BI /C2.1 r ROOF DRAIN CLEANOUT (CO) 0 MEDIUM DUTY HMA, SEE DETAIL Al /C2.1 CONCRETE SLAB, SEE STRUCTURAL GENERAL NOTES 1. THE BURIED UTILITIES ON THIS PROJECT ARE SHOWN IN THEIR APPROXIMATE LOCATION WHERE KNOWN OTHER EXISTING BURIED UTILITIES MAY NOT BE SHOWN ON THESE PLANS. THE CONTRACTOR SHALL CONTACT ALL UTILITY COMPANIES AND HAVE THEIR LOCATION MARKED ON THE GROUND PRIOR TO CONSTRUCTION THE CONTRACTOR WILL PROTECT, OR IMMEDIATELY REPAIR ANY DAMAGED UTIUTY "DISCOVERED" D ON THIS PROJECT WITHOUT ADDITIONAL COSTS 2. MAINTAIN 6" MINIMUM VERTICAL AND 3' MINIMUM HORIZONTAL CLEARANCE (OUTSIDE SURFACES) BETWEEN STORM DRAIN PIPES AND OTHER UTIUTY PIPES AND CONDUITS, UNLESS OTHERWISE NOTED. 3. CONTRACTOR AND /OR SURVEYOR SHALL CALCULATE PIPE SLOPES BASED ON THE INVERT ELEVATIONS SHOWN ON THE PLANS PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER OF ANY DISCREPANCIES PRIOR 70 FIELD STAKING AND CONSTRUCTION, 4. ALL ROOF DRAIN (RD) LINES TO BE 6" PVC SDR -35, SEE PLAN FOR SLOPE. 5. CHECK CROSS SLOPE FROM THE PROPOSED GRADE TO THE EXISTING GRADE PRIOR TO POURING CONCRETE. NOTIFY ENGINEER IF SLOPE IS LESS THAN WHAT IS SHOWN ON PLANS. � �yi�i���•7�l =ILL zr5e l . mAI 1. TOP OF WATER = 366.91 BOTTOM 6" ROOF ORLON = 367.4 SEPARATION : 0.50' NOTE: GENERAL CONTRACTOR TO POTHOLE EXISTING WATER MAIN TO DETERMINE EXACT HORIZONTAL AND VERTICAL LOCATION AND NOTIFY ARCHITECT/ENGINEER IF 6- INCHES OF SEPARATION CANNOT BE OBTAINED PRIOR TO ANY DOWNSPOUT ONE INSTALLATION. 2. TOP OF 6" STORM = 354.50 BOTTOM 6" ROOF DRAIN = 365.14 SEPARATION - 0.64' CLEANOUT SCHEDULE STRUCTURE R INVERT ELEV. NOTES ID E,EV. MATCH FINISH GRADE CO #01 368.85 IE= 367.17 W /LOCKING COVER, SEE DETAIL B2 /C21 MATCH FINISH (FADE CO 002 369.94 IE= 367.73 W/LOCKING COVER, SEE DETAIL B2/C2.1 MATCH FINISH GRADE CO 003 368.75 IE= 365.41 W /LOCKNG COVER, SEE DETAIL B2/C2.1 MATCH FINISH GRADE CO 0D4 368.91 IE= 365.73 W /LOCKING COVER, SEE DETAIL 82/C21 MATCH FINISH GRADE CO 005 368.86 IE= 365.09 W /LOCKING COVER, SEE DETAIL B2 /C2.1 SITTS & HILL ENGINEERS, INC. CIVIL • STRUCTURAL • SURVEYING 4815 CENTER STREET TACOMA. WA. 98409 PHONE: (253) 474 -9M9 Project No.: 1653 8 Projwt Mg.: M3.M, Proj Engineer. K.H. I Pro} Rafter. J.M.W. z LU \ �3 O F, o � a xg �m Z 0 F2 LU Z Q 'd V Z Q CL' Z Q H O r /Q V Z U Q LL N 0 LU Cn Q J CL O 0 N C14 Z Z 0 LU O U LU n J � W ,c Z C f= Oo CL 0 J_ E } } A. HA C '�F R4trrarssE° tf+A4 �SIONAL 8s0� 9a7>M7T6 Project: 2015 -20 Drawn: JMW BID SET 06/29/15 Sheet. C2.0 C 3° COMPACTED DEPTH CLASS 1/2° HMA 6' COMPACTED DEPTH CRUSHED SURFACING TOP COURSE, COMPACT TO 95% MAXIMUM DENSITY - PREPARED SUBGRADE, COMPACT UPPER 12' TO 95% MAXIMUM DENSITY —1 PLACE 4' WIDE z 1/8' DEEP SQUEEGEE FORMED HOT POURED RUBBERIZED ASPHALT OVERBAND JOINT SEAL ( WSOOT 9 -04.10 OR APPROVED EQUAL), TV. —, SAW CUT SMOOTH VERTICAL JOINT. APPLY ASPHALT TACK COAT TO ALL THOROUGHLY CLEANED E %POSED PAVEMENT SURFACES MMEDIATELY POOR TO PAVING.— REMOVE EXISTING PAVEMENT (2' MIN. DEPTH) AND REPLACE AS PART OF NEW PAVEMENT FINISH GRADE 4" MIN COMPACTED DEPTH CRUSHED SURFACING BASE COURSE PER VSDOT SPECIFICATION 9- 03.9(3), COMPACTED TO 95% MAXIMUM DRY DENSITY --� SUBGRADE - COMPACT UPPER 12' TO 95% MAXIMUM DRY DENSTY, APPROVED FOR CONSTRUCTION BY: DATE: Director of Public Works APPROVAL EXPIRES: (i"3� "�a✓TY�y�.:� -� r"x•"�""•`6.`^�Y*`��`�� BARS 1 5 /8' THICK 2 1/Y �M UNDISTURBED E %ISTING BASE COURSE PROPOSED ASPHALT PAVEMENT, SEE PLAN THIS BAR 1- THIS AREA SCALE: N.T.S. THICK (TYP. THEINMATIC �(�� ) TO M MAX. DENSITY. EXISTING PgVEMFNT SECTION FOR PAVEMENT SECTION HEAD) CAP SCREWS 2' LONG. 3/4 } 1/4^ DRILL HOLES SPACED 120' O 11 1) TRENCH WIDTH SHALL BE AS SPECIFIED IN SECTION 2 -09.4 OF THE STANDARD SPECIFICATIONS W (SEE NOTE 1) T— 2. MATERIAL IS DUCTILE IRON DETECTABLE MARKING TAPE 1 3/4' TYP. I EXISTING GREM n 12-18' BELOW FINISH GRADE. �1 MEDNM DUTY ASPHALT PAVEMENT PAVEMBVT JOINT SECTION CFIU� I® SURFACING SECTION n PIPE ZONE BEDDING AND BACKRLL DETAIL INK FENCE TO REMAIN D4 !11 „�' MV 9Diipl YEW LEVFllNG PADSy BACK FlLL ENGINEERS, INC. (NP. 8 PLCS.) SCALE: N.T.S. SCALE: N.T.S. SCALE N.T.S. 4815 CENTER STREET TACOMA. WA. 98409 I PHONE: (253) 47H9449 4' DIAMETER DOWNSPOUT Project NO.: 16538 Project Mgr.: M.LM. Proj. Engineer: K.H. Pro} DraRer: J.M.W. PROVIDE PVC ADAPTER/BUSHING REDUCER AS REWIRED. H -20 RATED, LOCKING SOLD 4' MALE THREAD CAP COVER W/ STAINLESS STEEL I 22.5' PLAY SHED CONCRETE SLAB - CONCRETE W 2 SQUARE NUT / SET SCREW. COVER SHALL BE STAMPED: 'CO'. OFCO 2'x12' PRESSURE TREATED BOARD. SEE STRUCTURAL DRAWINGS COVER. SEE PROVIDE MOCK -UP OF DOWNSPOUT M1007 D T OR EQUAL / NOTCH AT FENCE POST CONCRETE FOOTINGS. PLACE WITHIN 1 -INCH FIR I, STRUCTURAL-,, AL PRIOR ASSEMBLY FOR APPROVAL PRIOR TO CHAINUNK FENCE. INSTALLATION i FINISH 4- 'y CLEAN OUT: LOCATE GRADE BOT70M OF 'y CLEAN OUT'°T' FITTING O TOP OF FINISH GRADE II "�" `� W • I 8" 0 PIPE ----�� EXISTING 3 i 6'0 ELL FITTING GRADE v 6'0 0.5' FITTING FIBER JOINT PACKING LOOP END OF TRACER WIRE 6'0 45' FITTING AT UPHILL END 6' 0 P.V.C. PIPE IN CLEANOUT CASING Z OF ROOF DRAIN SYSTEM. WYE ALONG COLLECTOR LINE SEE 45' BEND / ` PLAN FOR LOCATION. MAX 3• DEEP z 12^ AGE NOTCH IN 31 - 1 FOOTING ALLONED FOR DOWNSPOUT yl4 'RACLR HIRE ( LEADER INSTALLATION DOWNSPOUT COLLECTOR SEE PLAN CRUSHED SURFACING BASE COURSE - COMPACT. SEE SECTION A3/C2.1 TYPICAL DOWNSPOUT CONNECTION DRAIN CLEAN -OUT DETAIL o�"SSTORM SCALE: N.T.S. 3' LONG 4'0' PRESSURE TREATED POST. SPACE AT 8' -0' O.C. MAX TOP MIN. 1'-6 1/47 7/8' TYP. r 1' F1 5/8' TYP. MIN. 41/2 � /AI I I IY /lTA 1 5/ 3/4' 8' � 1 -8' 2 1/4' 9ECIDN A -A -A 1. ES: 1. MATERIAL USED FOR THE FRAME SHALL BE DUCTILE IRON DULY. Z. OLYMPIC FOUNDRY PART NO. SM 60 D/T IS THE PRE - APPROVED EQUAL. NOTE SEE WSOOT STANDARD PLAN 8- 30.10 -00 FOR TYPE 1 CATCH 3, ALL OTHER PRODUCTS REQUIRE WRITTEN APPROVAL PRIOR TO USE. BASIN STRUCTURES. IF ANY INFORMATION SHOWN HEREON 4. TOP R FRAME SHALL BE ADJUSTED EVEN NTH ROADWAY SECTION. DIFFERS FROM THAT SHOWN ON THE WSOOT STANDARD PLAN, THE WSOOT 5. DUCTILE IRON ASTM A 536 88055 -06 H -20 RATED, APPROX. STANDARD PLAN SHALL GOVERN. 124 LBS. �1 BOLT -DOWN CATCH BASIN FRAME DETAIL SCALE: N.T.S. 1 1/8' TYP. B/ TYP. SL 1 1/4' 1T/02 TIERS RECESSED FLUSH 1 Y INSEF HEX O ( O T 5 /8' O 5/8' -11 = UNC -2A 1/2, TYP 2. 2' TYP. _ 45' 3 /4' 1 '/" '1P. TOP VEAL i NOTES �SE-G�RM ® G B10LT 3 * 1. MATERIAL USED FOR RATE SHALL BE n � ^ DUCTILE IRON DULY. 2 -0' 2. DU CTILE IRON ASTM A536 OR 8055 -06 H -20 1 5/8' RATED, APPROXIMATELY 104 IBS. 3. OLYMPIC FOUNDRY PART NO. SM 60 D/T IS 1 3/4' -•I PRE - APPROVED. ALL OTHER PRODUCTS REQUIRE R =7 1/4' WRITTEN APPROVAL PRIOR TO USE 7/8^ 3/4' ^ NOTE: SEE '!SOOT STANDARD PLAN 2•_O' 8- 30.50 -00 FOR TYPE 1 CATCH FRW BASIN STRUCTURES. IF ANY INFORMATION SHOWN HEREON DIFFERS FROM THAT SHOWN ON THE WSOOT STANDARD PLAN, THE WSDOT STANDARD PLAN SHALL GOVERN. BOLT -DOWN CATCH BASIN HERRINGBONE GRATE DETAIL DETAIL SCALE: N.T.S. ' 2 °SO. JND PICK NOTCH CON61 Sm 5 /8' BARS 1 5 /8' THICK 2 1/Y �M THIS AREA BARS 13/8' THICK 2' _ ne PRESSURE TREATED CURB DETAIL THIS BAR 1- THIS AREA SCALE: N.T.S. THICK (TYP. THEINMATIC �(�� ) TO M MAX. DENSITY. 304 STEEL SOCKET HEAD (ALLEN 4 PLGS.) L_ HEAD) CAP SCREWS 2' LONG. 3/4 } 1/4^ DRILL HOLES SPACED 120' O 11 1) TRENCH WIDTH SHALL BE AS SPECIFIED IN SECTION 2 -09.4 OF THE STANDARD SPECIFICATIONS W (SEE NOTE 1) T— 2. MATERIAL IS DUCTILE IRON DETECTABLE MARKING TAPE 1 3/4' TYP. PEA GRAVEL FOR NON- PERFORATED TIGHTLNOD FOOTING DRAIN OUTLET PIPING AND ROOF DRAINS. n 12-18' BELOW FINISH GRADE. 3) PPE ZONE BACKFlLL SHALL BE IN ACCORDANCE WITH WSOOT STANDARD SPECIFICATIONS BID SET 06/29/15 TOP OF INSTALL 014 GAUGE COPPER n PIPE ZONE BEDDING AND BACKRLL DETAIL SUBGRADE TRACER WIRE DIRECTLY D4 PIPE ZONE .�, ABOVE ALL STORM UNES 9Diipl YEW LEVFllNG PADSy BACK FlLL ENGINEERS, INC. (NP. 8 PLCS.) (SEE NOTE 3) R'R:') 1 1/8' TYP. B/ TYP. SL 1 1/4' 1T/02 TIERS RECESSED FLUSH 1 Y INSEF HEX O ( O T 5 /8' O 5/8' -11 = UNC -2A 1/2, TYP 2. 2' TYP. _ 45' 3 /4' 1 '/" '1P. TOP VEAL i NOTES �SE-G�RM ® G B10LT 3 * 1. MATERIAL USED FOR RATE SHALL BE n � ^ DUCTILE IRON DULY. 2 -0' 2. DU CTILE IRON ASTM A536 OR 8055 -06 H -20 1 5/8' RATED, APPROXIMATELY 104 IBS. 3. OLYMPIC FOUNDRY PART NO. SM 60 D/T IS 1 3/4' -•I PRE - APPROVED. ALL OTHER PRODUCTS REQUIRE R =7 1/4' WRITTEN APPROVAL PRIOR TO USE 7/8^ 3/4' ^ NOTE: SEE '!SOOT STANDARD PLAN 2•_O' 8- 30.50 -00 FOR TYPE 1 CATCH FRW BASIN STRUCTURES. IF ANY INFORMATION SHOWN HEREON DIFFERS FROM THAT SHOWN ON THE WSOOT STANDARD PLAN, THE WSDOT STANDARD PLAN SHALL GOVERN. BOLT -DOWN CATCH BASIN HERRINGBONE GRATE DETAIL DETAIL SCALE: N.T.S. ' 2 °SO. JND PICK NOTCH CON61 Sm 5 /8' 0®OII DEFAL 11/16 111 1 /16'FROM CENTER 1516' /6^ NOTES, i. USE WITH THREE LOCKING BOLTS SUITABLE NATIVE MATERIAL PER CEOTECHNICAL ENGINEER, COMPACT 3/8' -11 NO STAINLESS TYPE THEINMATIC �(�� ) TO M MAX. DENSITY. 304 STEEL SOCKET HEAD (ALLEN HEAD) CAP SCREWS 2' LONG. 3/4 } 1/4^ DRILL HOLES SPACED 120' O 11 1) TRENCH WIDTH SHALL BE AS SPECIFIED IN SECTION 2 -09.4 OF THE STANDARD SPECIFICATIONS 1/16^ RADIUS BMX fD MM ATE -��A1 2. MATERIAL IS DUCTILE IRON SPECIFICATIONS SECTION 9 -03.12 (3). FOR DUCTILE IRON AND IHERMOPLASTIC /CPEP PIPE AND ASTM A 536 GRADE 8D- 55 -06. SECTION A -A 3/8' 1j 3/81 1 1/4* 1 1/2• TOP i8 aro PICK NOTCH OETAL SOLID LOCKING COVER SCALE: N.T.S. Z ;� LIB c3 O o 04 G<V m • t Z O Cn _ U_ cz UJ N J Q LU Q W^ V Q Z Q O! 0 Z IQ V Z E otf Q V 0 Z 'Q V Z U Q LL CY V) N 0 W N Q CL J O O N N Z Z° W O LUC L U N J w W - C 0 � Z E F CL U CJ_ E N_ FOUNDATION LEVEL `G9'Jcou'b4,° a s SUITABLE NATIVE MATERIAL PER CEOTECHNICAL ENGINEER, COMPACT ¢' one �`"CrsTEWE�1�4� THEINMATIC �(�� ) TO M MAX. DENSITY. SSTONAL EpO 08/2e/L6 NOTES: 1) TRENCH WIDTH SHALL BE AS SPECIFIED IN SECTION 2 -09.4 OF THE STANDARD SPECIFICATIONS 2) GRAVEL BACKFRL FOR PIPE ZONE BEDDING SHALL BE IN ACCORDANCE WITH WSOOT STANDARD SPECIFICATIONS SECTION 9 -03.12 (3). FOR DUCTILE IRON AND IHERMOPLASTIC /CPEP PIPE AND Project: 2015 -20 PEA GRAVEL FOR NON- PERFORATED TIGHTLNOD FOOTING DRAIN OUTLET PIPING AND ROOF DRAINS. Drawn: JMVV 3) PPE ZONE BACKFlLL SHALL BE IN ACCORDANCE WITH WSOOT STANDARD SPECIFICATIONS BID SET 06/29/15 SECTION 9- 03.14(1). n PIPE ZONE BEDDING AND BACKRLL DETAIL D4 SCALE: N.T.S. SITTS & HILL ENGINEERS, INC. Sheet, CIVIL • STRUCTURAL • SURVEYING 4815 CENTER STREET TACOMA. WA. 98409 L PHONE: (253) 47H9449 Project NO.: 16538 Project Mgr.: M.LM. Proj. Engineer: K.H. Pro} DraRer: J.M.W. FILL STANDARDS 1. FILLS WHICH ARE INTENDED FOR BUILDING SITES SHALL BE CONSTRUCTED IN CONFORMANCE WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE U.B.C. AS ADOPTED BY THE CITY, AND AN ASSIGNMENT OF ALLOWABLE SOIL - BEARING PRESSURES WILL BE UNDER THE JURISDICTION OF THE CITY BUILDING OFFICIAL IN ACCORDANCE WITH THE U.B.C. 2. SLOPES SHALL BE NO STEEPER THAN IS SAFE FOR THE INTENDED USE AND SHALL NOT BE STEEPER THAN TWO HORIZONTAL TO ONE VERTICAL, OR AS RECOMMENDED BY A SOIL ENGINEER, FILL SITES MUST BE APPROVED BY THE ENGINEER AS SUITABLE LOCATIONS FOR THE PROPOSED FILL THE GROUND SURFACE FOR FILLS OVER FIVE FEET IN HEIGHT SHALL BE PREPARED BY REMOVING VEGETATION, NONCOMPLYING FILL, TOPSOIL, AND OTHER UNSUITABLE MATERIALS; SCARIFYING TO PROVIDE A BOND WITH THE NEW FILL; AND, WHERE EXITING SLOPES ARE STEEPER THAN FIVE HORIZONTAL TO ONE VERTICAL, BY BENCHING INTO COMPETENT MATERIAL AS DETERMINED BY THE ENGINEER. THE BENCH UNDER THE TOE OF A FILL ON A SLOPE STEEPER THAN 5 HORIZONTAL TO 1 VERTICAL SHALL BE AT LEAST 10 FEET WIDE OR AS RECOMMENDED BY A SOIL ENGINEER. 3. EXCEPT AS PERMITTED BY THE CITY, NO MATERIAL OTHER THAN EARTH MATERIAL SHALL BE BURIED OR PLACED IN FILLS PLACEMENT OF OTHER THAN EARTH MATERIAL IS REGULATED BY STATE STATUTES OR FEDERAL LAWS. AND ADDITIONAL PERMITS MAY BE REQUIRED. 4. FILLS SHALL BE CONSTRUCTED USING EARTH MATERIALS, COMPACTION METHODS, AND CONSTRUCTION TECHNIQUES SO THAT TABLE FILLS ARE CREATED. 5. THE TOE OR CATCH POINT OF FILL SLOPES SHALL BE SET BACK FROM THE SITE BOUNDARY LINE IN ACCORDANCE WITH THE FOLLOWING TABLE, UNLESS A RETAINING WALL IS DESIGNED BY THE ENGINEER AND CONSTRUCTED FOR THE PROJECT. FED DEPTH SETBACK DISTANCE UNDER 5 FEET 2 FEET 5 - 40 FEET HEIGHT OF FILL OVER 40 FEET 20 FEET EXCAVATION NOTES 1. EXCAVATE TO ELEVATIONS. LINES AND GRADES INDICATED TO NOT MORE THAN 1/2 -INCH ABOVE OR BELOW THAT REQUIRED. 2. SLOPE SIDES OF EXCAVATION AS INDICATED OR COMPLY WITH LOCAL CODES AND ORDINANCES HAVING JURISDICTION, WHICHEVER IS MORE STRINGENT. SHORE AND BRACE WHERE SLOPING IS NOT POSSIBLE BECAUSE OF SPACE RESTRICTIONS OR STABILITY OF MATERIAL EXCAVATED. 3. STOCKPILE SATISFACTORY EXCAVATED MATERIALS WHERE DIRECTED UNTIL REQUIRED FOR BACKFILL OR FILL PUCE, GRADE AND SHAPE STOCKPILES FOR PROPER DRAINAGE, LOCATE AND RETAIN SOIL MATERIALS AWAY FROM EDGE OF EXCAVATIONS. 4. DISPOSE OF EXCESS SOIL AND UNSUITABLE SOIL MATERIAL OFF -SITE AS DIRECTED, COMPACTION NOTES 1. CONTROL SOIL COMPACTON DURING CONSTRUCTION PROVIDING MINIMUM PERCENTAGE OF DENSITY SPECIFIED FOR EACH AREA CLASSIFICATION. PERCENTAGES ARE RELATED TO MAXIMUM DRY DENSITY AS MEASURED IN CONFORMANCE WITH ASTM 0 1557. 2. COMPACT TOP 12- INCHES OF SUBGRADE (24- INCHES UNDER PROPOSED DRIVING SURFACES) TO 95- PERCENT OF MAXIMUM DRY DENSITY UNDER PAVEMENTS AND GRAVEL SURFACING. 3. WHERE SUBGRADE OR LAYER OF SOL MATERIAL MUST BE MOISTURE CONDITIONED BEFORE COMPACTION, UNIFORMLY APPLY WATER TO SURFACE OF SUBGRADE OR LAYER OF SOIL MATERIAL TO PREVENT FREE WATER APPEARING ON SURFACE DURING OR SUBSEQUENT TO COMPACTION OPERATIONS. REMOVE AND REPLACE, OR SCARIFY AND AIR DRY, SOIL MATERIAL THAT IS TOO WET TO PERMIT COMPACTION TO SPECIFIED DENSITY. SOIL MATERIAL THAT HAS BEEN REMOVED BECAUSE IT IS TOD WET TO PERMIT COMPACTION MAY BE STOCKPILED OR SPREAD AND ALLOWED TO DRY. ASSIST DRYING BY DISKING, HARROWING OR PULVERIZING UNTIL MOISTURE CONTENT IS REDUCED TO SATISFACTORY VALUE. STANDARD STORMWATER NOTES i. TEMPORARY EROION/WATER POLLUTION PREVENTION MEASURES SHALL BE REQUIRED IN ACCORDANCE WITH SECTION 1- 07,15, AS MODIFIED BY THE APWA SUPPLEMENT, OF THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATIONS AND THE CITY STORMWATER MANAGEMENT MANUAL 2 SHOULD THE TEMPORARY EROSION AND SEDIMENTATION CONTROL MEASURES AS SHOWN CN THIS DRAWING NOT PROVE ADEQUATE TO CONTROL EROSION AND SEDIMENTATION, THE APPLICANT /CONTRACTOR SHALL INSTALL ADDITIONAL FACIUTIES AS NECESSARY TO PROTECT ADJACENT PROPERTIES, SENSITIVE AREAS, NATURAL WATER COURSES AND /OR STORM DRAINAGE SYSTEMS 3. CALL THE UNDERGROUND LOCATE LINE 1 -BOO- 424 -5555 A MINIMUM OF 48 HOURS PRIOR TO ANY EXCAVATIONS. 4. ALL EROSION CONTROL AND STORMWATER FACILITIES SHALL BE REGULARLY INSPECTED AND MAINTAINED BY THE CONTRACTOR DURING CONSTRUCTION. 5. THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN THE EVENT OR DISCOVERY OF POOR SOILS, STANDING GROUNDWATER, OR SEVERE DISCREPANCIES FROM SOIL LOG DESCRIPTIONS AS NOTED ON THE PLANS. STANDARD NOTES 1. IT WILL BE THE CONTRACTOR'S RESPONSIBILITY TO CONTACT ALL UTILITY COMPANIES TO COORDINATE CONSTRUCTION. ALL UTILITY RELOCATION WORK SHALL BE AT THE EXPENSE OF THE CONTRACTOR AND MUST BE IN ACCORDANCE WITH STANDARDS OF THE COUNTY. 2. BURIED UTILITIES ARE SHOWN IN THEIR APPROXIMATE LOCATION. THE CONTRACTOR SHALL HAVE THE UTILITIES VERIFIED ON THE GROUND PRIOR TO CONSTRUCTION. 3. ANY REVISIONS TO THESE PLANS MUST BE RENEWED AND APPROVED BY THE CITY DEVELOPMENT ENGINEERING SECTION PRIOR TO ANY IMPLEMENTATION IN THE FIELD. 4. THE CONTRACTOR SHALL NOTIFY THE APPLICANT'S ENGINEER IN THE EVENT OR DISCOVERY OF POOR SOILS, STANDING GROUNDWATER OR SEVERE DISCREPANCIES FROM SOIL LOG DESCRIPTIONS AS NOTED ON THESE PLANS. 5. EXCAVATION STANDARDS- CUT SLOPES: SLOPES SHALL NOT BE STEEPER THAN 2 HORIZONTAL TO 1 VERTICAL, OR AS RECOMMENDED BY A SOILS ENGINEER. THE CATCH POINT OF THE TOP OF THE SLOPE SHALL BE SET BACK FROM THE SITE BOUNDARY LINE IN ACCORDANCE WITH THE FOLLOWING TABLE, UNLESS A RETAINING WALL IS DESIGNED BY THE ENGINEER AND CONSTRUCTED FOR THE PROJECT. OUT DEPTH SETBACK DISTANCE UNDER 5 FEET 2 FEET 5 - 20 FEET HEIGHT /2 OVER 20 FEET 10 FEET 6. FILL STANDARDS: FILL LOCATION: SLOPES SHALL NOT BE STEEPER THAN 1 1/2 2 HORIZONTAL TO 1 VERTICAL, OR AS RECOMMENDED BY A SOILS ENGINEER FILL SITES MUST BE APPROVED BY THE ENGINEER AS SUITABLE LOCATIONS FOR THE PROPOSED FILL. 7. PREPARATION OF GROUND: THE GROUND SURFACE FOR FILLS OVER 5 FEET IN HEIGHT SHALL BE PREPARED BY REMOVING VEGETATION, NONCOMPLYING FILL, TOPSOIL AND OTHER UNSUITABLE MATERIALS; SCARIFYING TO PROVIDE A BOND WITH THE NEW FILL; AND WHERE SKIS NO SLOPES ARE STEEPER THAN 5 HORIZONTAL TO 1 VERTICAL BY BENCHING INTO COMPETENT MATERIAL AS DETERMINED BY THE ENGINEER. THE BENCH UNDER THE TOE OF A FILL ON A SLOPE STEEPER THAN 5 HORIZONTAL TO 1 VERTICAL SHALL BE AT LEAST 10 FEET WIDE, OR AS RECOMMEND BY A SOILS ENGINEER. SETBACK FROM PROPERTY LINES: THE TOE OF CATCH POINT OF FILL SLOPES SHALL BE SET BACK FROM THE SITE BOUNDARY LINE IN ACCORDANCE WITH THE FOLLOWING TABLE, UNLESS A RETAINING WALL IS DESIGNED BY THE ENGINEER AND CONSTRUCTED FOR THE PROJECT. FILL DEPTH SET BACK DISTANCE UNDER 5 FEET 2 FEET 5 - 40 FEET HEIGHT/2 OVER 40 FEET 20 FEET B. ISSUANCE OF SITE DEVELOPMENT PERMIT BY THE CITY DOES NOT IMPLY OR SIGNIFY THAT THE PROPOSED WORK COMPILES WITH THE REQUIREMENTS OF OR IS ALLOYED BY OTHER COUNTY ORDINANCES, REGULATIONS OR REQUIREMENTS, OR STATE OR FEDERAL LAWS. THE CONTRACTOR WILL ACCEPT SOLE RESPONSIBILITY AND UABILITY FOR COMPLIANCE WITH ALL STATE, FEDERAL, AND LOCAL RULES. REQUIREMENTS. LAWS, ORDINANCES AND REGULATIONS. 9. THE SITE DEVELOPMENT PERMIT MUST BE POSTED BY THE CONTRACTOR AT THE DRIVEWAY LOCATION FOR THE DURATION OF THE CONSTRUCTION ACTIVITY. THE CONTRACTOR WILL BE RESPONSIBLE FOR THE WEATHERPROOFING OF THE PERMIT, POSTING APPARATUS, AND MAINTENANCE. 10. THE CITY IS AUTHORIZED TO MAKE INSPECTIONS AND TAKE SUCH ACTIONS AS REQUIRED TO ENFORCE THESE REGULATIONS. THE CITY REPRESENTATIVE SHALL PRESENT PROPER CREDENTIALS. 1. SUBGRADE BELOW STRUCTURAL FILL SHALL CONSIST OF FIRM, UNYIELDING NATIVE SOILS OR STRUCTURAL FILL MATERIALS, UNDER NO CIRCUMSTANCES SHALL FOUNDATIONS BE INSTALLED ATOP LOOSE, SOFT, OR FROZEN SOIL. SLOUGH, DEBRIS, EXISTING UNCONTROLLED FILL, OR SURFACES COVERED BY STANDING WATER. ANY LOCALIZED ZONES OF LOOSER GRANULAR SOILS OBSERVED WITHIN A SUBGRADE SHALL BE COMPACTED TO A DENSITY EQUAL TO THE SURROUNDING SOILS ANY ORGANIC, SOFT, OR PUMPING SOILS OBSERVED WITHIN A SUBGRADE SHALL HE OVEREXCAVATED AND REPLACED WIN STRUCTURAL FILL MATERIAL PER THE SUBSEQUENT PARAGRAPHS. SUBGRADE CONDITION SHALL BE VERIFIED BY THE GEOTECHNICAL ENGINEER OR SPECIAL INSPECTOR PRIOR TO PLACING STRUCTURAL FILL STANDARD STORMWATER NOTES 1. SHOULD THE TEMPORARY EROSION AND SEDIMENTATION CONTROL MEASURES AS SHOWN ON THIS DRAWING NOT PROVE ADEQUATE TO CONTROL EROSION AND SEDIMENTATION, THE APPLICANT /CONTRACTOR SHALL INSTALL ADDITIONAL FACILITIES AS NECESSARY TO PROTECT ADJACENT PROPERTIES, SENSITIVE AREAS, NATURAL WATER COURSES AND /OR STORM DRAINAGE SYSTEMS. 2. CALL THE UNDERGROUND LOCATE LINE 1 -600- 424 -5555 A MINIMUM OF 46 HOURS PRIOR TO ANY EXCAVATIONS. 3. A COPY OF THE APPROVED STORMWATER PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 4. ALL EROSION CONTROL AND STORMWATER FACILITIES SHALL BE REGULARLY INSPECTED AND MAINTAINED BY THE CONTRACTOR DURING CONSTRUCTION. UTILITY NOTES 1. PIPE BEDDING SHALL BE PER DETAIL C4/C2.1 FOR ALL PIPING SHOWN, UNLESS OTHERWISE NOTED. 2. DETECTABLE MARKING TAPE SHALL BE INSTALLED ALONG THE FULL LENGTH OF EACH PROPOSED UTILITY. DETECTION TAPE SHALL BE 2 -INCH 'WIDTH (MINIMUM). CONTAIN A 0.35 MIL SOLID ALUMINUM CORE, BE A MINIMUM OF 5.0 NIL OVERALL THICKNESS. AND BE SUITABLE FOR DIRECT BURY. THE TAPE SHALL BE COLOR CODED ACCORDING TO AWWA AND CONTINUOUSLY IMPRINTED WITH THE TYPE OF UTILITY FOR EACH UTILITY SHOWN. GRADING AND DRAINAGE NOTES 1. CONTRACTOR AND /OR SURVEYOR SHALL CALCULATE PIPE SLOPES BASED ON THE INVERT ELEVATIONS SHOWN ON THE PLANS PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER OF ANY DISCREPANCIES PRIOR TO FIELD STAKING AND CONSTRUCTION. 2. FOR CIRCULAR SOUD LOCKING COVER, SEE DETAIL 03/C2.1 OR APPROVED EQUAL 3. FOR HERRINGBONE GRATE. SEE DETAIL 02/C2.1. 4. ALL STORM DRAINAGE PIPING SHALL BE GASKETED AND WATERTIGHT APPROVED FOR CONSTRUCTION Z - BY: DATE: Director of Public Works W - 3 of O �o 0 v o4 U W APPROVAL EXPIRES: m Z O V) _ H U_ LU SITTS & HILL ENGINEERS, INC. CIVIL • STRUCTURAL • SURVEYING 4815 CENTER STREET TACOMA, WA. 98409 PHONE: (253) 474-9449 Project No.: 16538 Project Mgr.: M.L.M. Pmj. Engineer. K.H. Pro} Dreher, J.M.W. N W 0 Z 'W^ V Q Z Q Q' 0 Z 'Q V Z 0 Q V 0 W N Q J CL J O O U N CN 0 QN Z O W -C U W N J � W .� 0zD Z O 0 CL UCC <J_ C I G � p. HA ,'.��, FFCTSTEF5���1WW AS/ONAL ENG HM/�/l5 Project: 2015 -20 Drawn: JMw BID SET 06/29/15 Sheet: C2.2 m E o' °n 1 1 3" PVC CL 200 Fl / / � E%6T. PORTABLE 1 r \\ , Akfxif' FOOTING tl \ tl { tl EXIST. STORM DRAIN -i- - -� tl �m m a M M INA U b u i R Z \ \ \ u3ua -- „E_I _w� _— —. _ -. - W \ • . - "E -- �,. .aF —VfP -, -.a[ ___ __ riAE O U a co L PED uv 6 t n O U W \ U b u i R Z Q CL W 0 W S V) Q J O U F- ~ o w 0 u U W N J } W � Z 0O IL U J C ]9 5 REGISTERED AR HI CT YMOND C. TE OF WASHINGTDN Project: 2015 -20 Drawn: JTM. BID SET 06/29/15 Sh—,! SITE PLAN A 1.00 SCALE: 1 "= 20'-0" NORTH \ \ \ \ \ 6 t \ \ \ \ \ \ \ f6 b Z Q CL W 0 W S V) Q J O U F- ~ o w 0 u U W N J } W � Z 0O IL U J C ]9 5 REGISTERED AR HI CT YMOND C. TE OF WASHINGTDN Project: 2015 -20 Drawn: JTM. BID SET 06/29/15 Sh—,! SITE PLAN A 1.00 SCALE: 1 "= 20'-0" NORTH w m t a I 0 PROVIDE FULL DEPTH CLOSURE AT RAKES AND EAVES, TYR. DOWNSPOUT OF PIER 79' -6" OF PIER ELEVATION SCALE: 1/8" = 1' -0" C OF PIER C OF PIER 79'-6' SECTION SCALE: 1 /8' = 1'-0" 79'-6' I I EQ EO I I_ I D.S. LINE OF GUTTER AT ROOF v 1 OF PIER LINE OF GUTTER AT ROOF EDGE OF CONCRETE OF PIER 2" WHITE 26-6 26'L" I GAME LINES, TYP. I ADDITIONAL BEAMS REQUIRED FOR FORWARD BRACED I BASKETBALL ASSEMBLY, TYP. I CONTROL JOINT q II 1 I BASKETBALL BACKBOARD ASSEMBLY I ttP. OF 121. COORDINATE W/ MTL. �. 3 — + BUILDING MANUF. FOR ATTACHMENT A2.00 I / L PORTAL FRAME CONTROLJOINI - 4" CONCRETE SLAB SEE STRUCT. LIGHT BROOM FINISH ) I RIGID FRAME, TYP. 7' WHITE GAME LINES, TYP. PORTAL FRAME 1 I I D.S. I I ADDITIONAL BEAMS REQUIRED FOR FORWARD BRACED BASKETBALL ASSEMBLY, IYP. � I I I I I 1 2t'-0 I� I I I 4 I 9 P - - - - _ DTJ _ I Im am LINE Of ROOF ABOVE BASKETBALL BACKBOARD TYP. OF 121, SEE SPECS. FLOOR PLAN SCALE: 1/8" = V-Y' 3 A2.00 METAL ROOF PANELS \ PROVIDE BEEHIVE SCREEN AT EA CH DOWNSPOUT 12 1 /8N7k5" GALV. BASE BRAT. 1 /8N2" AS" GALV. BASE BRKT. 2 3 PRE- FINISHED GUTTER TOP OF RIGID FRAME #8 SS I. SHEET MTL. #8 SSTL. SHEET MIL. / SCREWS EA. SIDE jR SCREWS EA. SIDE • d < 2. -0.. RIGID FRAME, PAIN` 6 45 °ttP. d • A2.00 CONCRETE COLUMN. 4 ttP STRUCTURAL MASONRY I -BEAM ad • • SEE STRUCT. I RIGID FRAME DOWNSPOUT d • NOTE: ALL COMPONENTS OF - w • - • - CL OF COLUMN 8 BEAM 4 CONC. SLAB o FRAMEITO BE PAINTED A2 ttP e SEE STRUCT. SACK AND PATCH 912 . GALV. STRAP 12 GA. GALV. STRAP • ° _ _ _ COLUMN. ttP. '�' I -- - - - -- - - - - - - - `� D { I MUB CONNECTION, SEE CIVIL \ PROVIDE (2)BEACKEM PRE D.9. e • • I - RADIUS, 11, CROSS11ES, PATALL J J RIGID FRAMES. SEE STRUCT. 2. -0.. 42-0 2' -0.. 3" ED, PVC DOWNSPOUT 3" I.D. PVC DOWNSPOUT I -BEAM BY BLDG. MANUF. STRAP W/ 1/4"0 SSTL. ANCHOR BOLTS. SLEEVE INTO CONCRETE STRAP RI GALV, STL. ANCHOR BOLTS. IN CL SLEEVE INTO O BRICK VENEER. OF COLUMN E BEAM DOWNSPOUT @ COLUMN DOWNSPOUT @ I -BEAM COLUMN DETAIL SECTION DTL- 24.dwg Scale: 3" = 1' -0" DTL- 23.dwg Scale: 3" = 1' -0" COLUMN- DTL.dwg Scale: V= 1' -0" SCALE: 1/8" = 1' -0" 4 N Lu Q DV Z O R w Z O LLJQ 1 J w Z EL Q 0 w 2 } Q D_ Z �s w =3 > m O o oo o� U m Z f O _U W 0 W J J O O Z U i Uf Q Z O CW O U W N J >' W :� o� Z� OE O U CJ 1= } N."'MIT 7E Project: 2015 -20 Drawn: JTM BID SET 06/29/15 Sheet: o A2.00 OF PIER LINE OF GUTTER AT ROOF EDGE OF CONCRETE OF PIER OF PIER 26-6 26'L" _ I D.S. I I ADDITIONAL BEAMS REQUIRED FOR FORWARD BRACED BASKETBALL ASSEMBLY, IYP. � I I I I I 1 2t'-0 I� I I I 4 I 9 P - - - - _ DTJ _ I Im am LINE Of ROOF ABOVE BASKETBALL BACKBOARD TYP. OF 121, SEE SPECS. FLOOR PLAN SCALE: 1/8" = V-Y' 3 A2.00 METAL ROOF PANELS \ PROVIDE BEEHIVE SCREEN AT EA CH DOWNSPOUT 12 1 /8N7k5" GALV. BASE BRAT. 1 /8N2" AS" GALV. BASE BRKT. 2 3 PRE- FINISHED GUTTER TOP OF RIGID FRAME #8 SS I. SHEET MTL. #8 SSTL. SHEET MIL. / SCREWS EA. SIDE jR SCREWS EA. SIDE • d < 2. -0.. RIGID FRAME, PAIN` 6 45 °ttP. d • A2.00 CONCRETE COLUMN. 4 ttP STRUCTURAL MASONRY I -BEAM ad • • SEE STRUCT. I RIGID FRAME DOWNSPOUT d • NOTE: ALL COMPONENTS OF - w • - • - CL OF COLUMN 8 BEAM 4 CONC. SLAB o FRAMEITO BE PAINTED A2 ttP e SEE STRUCT. SACK AND PATCH 912 . GALV. STRAP 12 GA. GALV. STRAP • ° _ _ _ COLUMN. ttP. '�' I -- - - - -- - - - - - - - `� D { I MUB CONNECTION, SEE CIVIL \ PROVIDE (2)BEACKEM PRE D.9. e • • I - RADIUS, 11, CROSS11ES, PATALL J J RIGID FRAMES. SEE STRUCT. 2. -0.. 42-0 2' -0.. 3" ED, PVC DOWNSPOUT 3" I.D. PVC DOWNSPOUT I -BEAM BY BLDG. MANUF. STRAP W/ 1/4"0 SSTL. ANCHOR BOLTS. SLEEVE INTO CONCRETE STRAP RI GALV, STL. ANCHOR BOLTS. IN CL SLEEVE INTO O BRICK VENEER. OF COLUMN E BEAM DOWNSPOUT @ COLUMN DOWNSPOUT @ I -BEAM COLUMN DETAIL SECTION DTL- 24.dwg Scale: 3" = 1' -0" DTL- 23.dwg Scale: 3" = 1' -0" COLUMN- DTL.dwg Scale: V= 1' -0" SCALE: 1/8" = 1' -0" 4 N Lu Q DV Z O R w Z O LLJQ 1 J w Z EL Q 0 w 2 } Q D_ Z �s w =3 > m O o oo o� U m Z f O _U W 0 W J J O O Z U i Uf Q Z O CW O U W N J >' W :� o� Z� OE O U CJ 1= } N."'MIT 7E Project: 2015 -20 Drawn: JTM BID SET 06/29/15 Sheet: o A2.00 GENERAL NOTES THESE GENERAL NOTES ARE TO BE USED AS A SUPPLEMENT TO THE SPECIFICATIONS. ANY DISCREPANCIES FOUND AMONG THE DRAWINGS, THE SPECIFICATIONS, THESE GENERAL NOTES AND THE SITE CONDITIONS SHALL BE REPORTED TO THE ARCHITECT, WHO SHALL CORRECT SUCH DISCREPANCY IN WRITING. ANY WORK DONE BY THE GENERAL CONTRACTOR AFTER DISCOVERY OF SUCH DISCREPANCY SHALL BE DONE AT THE GENERAL CONTRACTOR'S RISK. THE GENERAL CONTRACTOR SHALL VERIFY AND COORDINATE DIMENSIONS AMONG ALL DRAWINGS PRIOR TO PROCEEDING WITH ANY WORK OR FABRICATION. THE STRUCTURE HAS BEEN DESIGNED TO RESIST CODE SPECIFIED VERTICAL AND LATERAL FORCES AFTER THE CONSTRUCTION OF ALL STRUCTURAL ELEMENTS HAS BEEN COMPLETED. STABILITY OF THE STRUCTURE PRIOR TO COMPLETION IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. THIS RESPONSIBILITY INCLUDES BUT IS NOT LIMITED TO JOB SITE SAFETY; ERECTION MEANS, METHODS, AND SEQUENCES; TEMPORARY SHORING, FORMWORK, BRACING; USE OF EQUIPMENT AND CONSTRUCTION PROCEDURES. PROVIDE ADEQUATE RESISTANCE TO LOADS ON THE STRUCTURES DURING CONSTRUCTION PER SEI /ASCE STANDARD NO. 37 -02 "DESIGN LOADS ON STRUCTURES DURING CONSTRUCTION." CONSTRUCTION OBSERVATION BY THE STRUCTURAL ENGINEER IS FOR GENERAL CONFORMANCE WITH DESIGN ASPECTS ONLY AND IS NOT INTENDED IN ANY WAY TO REVIEW THE CONTRACTOR'S CONSTRUCTION PROCEDURES. STANDARDS ALL METHODS, MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE 2012 INTERNATIONAL BUILDING CODE (IBC) AS AMENDED AND ADOPTED BY THE LOCAL BUILDING OFFICIAL OR APPLICABLE JURISDICTION. CONTRACT DRAWINGS / DIMENSIONS ARCHITECTURAL DRAWINGS ARE THE PRIME CONTRACT DRAWINGS. CONSULTANT DRAWINGS BY OTHER DISCIPLINES ARE SUPPLEMENTARY TO ARCHITECTURAL DRAWINGS. REPORT DIMENSIONAL OMISSIONS OR DISCREPANCIES BETWEEN ARCHITECTURAL DRAWINGS AND STRUCTURAL, MECHANICAL, ELECTRICAL OR CIVIL DRAWINGS TO ARCHITECT PRIOR TO PROCEEDING WITH WORK. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS. PRIMARY STRUCTURAL ELEMENTS ARE DIMENSIONED ON STRUCTURAL PLANS AND DETAILS AND OVERALL LAYOUT OF STRUCTURAL PORTION OF WORK. SOME SECONDARY ELEMENTS ARE NOT DIMENSIONED SUCH AS, WALL CONFIGURATIONS. INCLUDING EXACT DOOR AND WINDOW LOCATIONS, ALCOVES, SLAB SLOPES AND DEPRESSIONS, CURBS, ETC. VERTICAL DIMENSIONAL CONTROL IS DEFINED BY ARCHITECTURAL WALL SECTIONS AND BUILDING SECTIONS. STRUCTURAL DETAILS SHOW DIMENSIONAL RELATIONSHIPS TO CONTROL DIMENSIONS DEFINED BY ARCHITECTURAL DRAWINGS. DETAILING AND SHOP DRAWING PRODUCTION FOR STRUCTURAL ELEMENTS WILL REQUIRE DIMENSIONAL INFORMATION CONTAINED IN EIM ARCHITECTURAL AND STRUCTURAL DRAWINGS. DESIGN CRITERIA VERTICAL LOADS AREA DESIGN DEAD LIVE LOAD I COLATERAL I ZONE 2 LOAD 1 LOAD ROOF 1 10 PSF 1 25 PSF 1 3 PSF N W: (MINIMUM ROOF SNOW LOAD = 25 PSF) Pg = 25 PSF = GROUND SNOW LOAD Pf = 0.7CeCtlsPg = FLAT ROOF SNOW LOAD Ps = CsPf = SLOPED ROOF SNOW LOAD Is= 1.0 Ce = 1.0, Ct = 1.0, Cs = VARIES SCOPE OUR SCOPE IS LIMITED TO THE MAIN FRAME FOUNDATION DESIGN ONLY AS THE MAJORITY IS BIDDER DESIGNED PRE - MANUFACTURED BUILDING COMPONENTS AS A DEFERRED SUBMITTAL. GENERAL ASSUMPTIONS OF PRE - MANUFACTURED BUILDING COLUMN LOCATIONS AND PORTAL FRAME LOCATIONS HAVE BEEN INDICATED ON PLANS. THE GENERAL CONTRACTOR AND PRE - MANUFACTURED BUILDING SUBCONTRACTORS ARE RESPONSIBLE TO COORDINATE THE LAYOUT WITH THESE LOCATIONS AND FOOTING SIZE ASSUMPTIONS. ALL STAMPED FINAL FABRICATION SHOP DRAWINGS AND CALCULATIONS SHALL BE SUBMITTED TO PCS A MINIMUM OF TWO WEEKS PRIOR TO FOUNDATION SHOP DRAWING CREATION IN ORDER TO ALLOW COORDINATION AND POSSIBLE REVISIONS TO FOUNDATION SIZE ASSUMPTIONS PRIOR TO REBAR FABRICATION. THE PRE - MANUFACTURED ENGINEER OF RECORD (EOR) IS RESPONSIBLE FOR ALL OTHER STRUCTURE. LATERAL DRIFT LIMITS ON ALL PRE - MANUFAFCTURED FRAMES SHALL BE LIMITED TO H /200 FOR WIND OR SEISMIC LOADS. LATERAL FORCES LATERAL FORCES ARE TRANSMITTED BY A ROD BRACED ROOF TO MOMENT FRAMES. LOADS ARE THEN TRANSFERRED TO FOUNDATION BY MOMENT FRAME ACTION WHERE ULTIMATE DISPLACEMENT IS RESISTED BY PASSIVE PRESSURE OF EARTH AND /OR SLIDING FRICTION. OVERTURNING IS RESISTED BY DEAD LOAD OF THE STRUCTURE. NNp; THE BUILDING MEETS THE CRITERIA TO USE THE "METHOD 2 - SIMPLIFIED ENVELOPE PROCEDURE" PER ASCE 7 -10. - EXPOSURE CATEGORY = B - BASIC WIND SPEED (3 SEC. GUST), VOLT = 115 MPH - RISK CATAGORY PER TABLE 1.5 -1 = DT - TOPOGRAPHIC FACTOR Kzt = 1.0 - INTERNAL PRESSURE COEFFICIENT (OPEN) = f 0.0 - COMPONENTS AND CLADDING LOADS, SEE THE FOLLOWING TABLES: ROOF SURFACES' 51.00 POSITIVE PRESSURES (PSF) NEGATIVE PRESSURES (PSF) EFFECTIVE WIND AREA ZONE 2 ITEM 1 2 3 1 2 3 10 SF 16.0 16.0 16.0 -21.8 -37.9 (PCY) 20 SF 16.0 16.0 16.0 -21.2 -34.9 FOUNDATIONS - LINO 50 SF 16.0 16.0 16.0 -20.4 -30.9 0.50 100 SF 16.0 16.0 16.0 -19.8 -27.8 WALL SURFACES AND ROOF OVERHANGS' POSITIVE PRESSURE (PSF) NEGATIVE PRESSURE (PSF) ROOF OVERHANGS (PSF) EFFECTIVE WIND AREA ZONE 2 4 5 4 5 2 3 10 SF N/A N/A N/A N/A -44.4 -74.6 20 SF N/A N/A N/A N/A -44.4 -67.3 50 SF N/A N/A N/A N/A -44.4 -573 100 SF N/A N/A N/A N/A -44.4 -50.4 500 SF N/A N/A N/A N/A - - 1. NET WIND PRESSURES AT ROOF SURFACES = VALUE FROM TABLE ABOVE -2/3 ACTUAL DEAD LOAD. 2. ZONES ARE AS DEFINED BY FIGURE 30.5 -1 IN ASCE 7 -10. SEISMIC: (ASCE 7 -10) V = CSW WHERE CS = SDS . NTH (t) Cs MINIMUM = 0.044 SosTe 2 0.01 OR O.SSt Cs MINIMUM = R FOR Si > 0.6g le Sot Cs MAXIMUM = T(t) FOR T S TL OR SD1TL Cs MAXIMUM = T2( R FORT > Ti SEISMIC IMPORTANCE FACTOR, b = 1.25 RISK CATEGORY OF BUILDING PER TABLE 1.5 -1 = III SPECTRAL RESPONSE ACCELERATIONS Ss = 1.25 S/= .50 SITE CLASS PER TABLE 20.3 -1 = D DESIGN SPECTRAL RESPONSE ACCELERATIONS Sos = .83 & Sot = .50 SEISMIC DESIGN CATEGORY = D W = EFFECTIVE SEISMIC WEIGHT OF BUILDING = 145k ANALYSIS PROCEDURE USED = EQUIVALENT LATERAL FORCE PROCEDURE RESPONSE MODIFICATION FACTOR PER TABLE 12.2 -1, R = 3.5 Cs = .297 DESIGN BASE SHEAR V = 43k PIPES, DUCTS AND MECHANICAL EQUIPMENT SUPPORTED OR BRACED FROM STRUCTURE. CONFORM TO SHEET METAL AND AIR CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION, INC. PUBLICATION "SEISMIC RESTRAINT MANUAL GUIDEUNES FOR MECHANICAL SYSTEMS ". SPRINKLER LINE ATTACHMENTS SHALL CONFORM TO NFPA PAMPHLET 13. FOUNDATION DESIGN CRITERIA SOIL BEARING PRESSURE: 2000 PSF PASSIVE RESISTANCE: 250 PCF (INCLUDES F.O.S. > 1.5) COEFFICIENT OF FRICTION: .35 (INCLUDES F.O.S. ? 1.5) •1/3 INCREASE ALLOWED FOR SEISMIC OR WIND LOADING ALL FOOTINGS SHALL BEAR ON FIRM, UNDISTURBED EARTH OR "STRUCTURAL BACKFILL". NATIVE EARTH BEARING SHALL BE SURFACE COMPACTED. AREAS OVER- EXCAVATED SHALL BE BACKFILLED WITH LEAN CONCRETE (F'c =2000 PSI) OR "STRUCTURAL BACKFILL ". AREAS DESIGNATED 'STRUCTURAL BACKFILL" SHALL BE FILLED WITH APPROVED WELL- GRADED BANKRUN MATERIAL. MAXIMUM SIZE OF ROCK 4 ". FROZEN SOIL, ORGANIC MATERIAL AND DELETERIOUS MATTER NOT ALLOWED. COMPACT TO AT LEAST 95% OF ITS MAXIMUM DENSITY AS DETERMINED BY ASTM 01557. CONTRACTOR SHALL EXERCISE EXTREME CARE DURING EXCAVATION TO AVOID DAMAGE TO BURIED LINES, TANKS, AND OTHER CONCEALED ITEMS. UPON DISCOVERY, DO NOT PROCEED WITH WORK UNTIL RECEIVING WRITTEN INSTRUCTIONS FROM ARCHITECT. A COMPETENT REPRESENTATIVE OF THE OWNER SHALL INSPECT ALL FOOTING EXCAVATIONS FOR SUITABILITY OF BEARING SURFACES PRIOR TO PLACEMENT OF REINFORCING STEEL PROVIDE DRAINAGE AND DEWATERING AROUND ALL WORK TO AVOID WATER - SOFTENED FOOTINGS. CONCRETE MIX DESIGNS: THE CONTRACTOR SHALL DESIGN CONCRETE MIXES THAT MEET OR EXCEED THE REQUIREMENTS OF THE CONCRETE MIX TABLE. THE MIX DESIGNS SHALL FACILITATE ANTICIPATED PLACEMENT METHODS, WEATHER, REBAR CONGESTION, ARCHITECTURAL FINISHES, CONSTRUCTION SEQUENCING, STRUCTURAL DETAILS, AND ALL OTHER FACTORS REQUIRED TO PROVIDE A STRUCTURALLY SOUND, AESTHETICALLY ACCEPTABLE FINISHED PRODUCT. WATER REDUCING ADMIXTURES WILL LIKELY BE REQUIRED TO MEET THESE REQUIREMENTS. CONCRETE MIX DESIGNS SHALL CLEARLY INDICATE THE TARGET SLUMP. SLUMP TOLERANCE SHALL BE t 1 -1/2 INCHES. AGGREGATE: COARSE AND FINE AGGREGATE SHALL CONFORM TO ASTM C33 EC MENT: CEMENT SHALL CONFORM TO ASTM C150, TYPE II PORTLAND CEMENT, UNLESS NOTED OTHERWISE. FLYASH SHALL CONFORM TO ASTM C618 CLASS C OR F, MAXIMUM LOSS OF IGNITION SHALL BE 1.0% SLAG: GROUND GRANULATED BLAST - FURNACE (GGBF) SLAG SHALL CONFORM TO ASTM C989 GRADE 100 OR 120. ALTERNATE MIX DESIGNS: VARIATIONS TO THE MIX DESIGN PROPORTIONS MAY BE ACCEPTED IF SUBSTANTIATED IN ACCORDANCE WITH ACI 318, CHAPTER 5. PROVIDE SUBMITTALS A MINIMUM OF TWO WEEKS PRIOR TO BID FOR DETERMINATION OF ACCEPTABILITY. ADMIXTURES: ADMIXTURES SHALL BE BY MASTER BUILDERS, W.R. GRACE, OR PRE - APPROVED EQUAL. ALL MANUFACTURERS RECOMMENDATIONS SHALL BE FOLLOWED. WATER: SHALL BE CLEAN AND POTABLE. MAXIMUM CHLORIDE CONTENT: THE MAXIMUM WATER SOLUBLE CHLORIDE CONTENT SHALL NOT EXCEED 0.15% BY WEIGHT OF CEMENTITIOUS MATERIAL UNLESS NOTED OTHERWISE. CONCRETE EXPOSED TO WEATHER: PROVIDE 5.0% TOTAL AIR CONTENT FOR ALL CONCRETE EXPOSED TO WEATHER. TOTAL AIR CONTENT IS THE SUM OF ENTRAINED AIR PROVIDED BY ADMIXTURES AND NATURALLY OCCURRING ENTRAPPED AIR. AIR CONTENT SHALL BE TESTED PRIOR TO BEING PLACED IN THE PUMP HOPPER OR BUCKET; IT IS NOT REQUIRED TO BE TESTED AT THE DISCHARGE END OF THE PUMP HOSE. THE TOLERANCE ON ENTRAPPED AIR SHALL BE +2.0% AND -1.5% WITH THE AVERAGE OF ALL TESTS NOT LESS THAN THE SPECIFIED AMOUNT. TOTAL CEMENTITIOUS MATERIAL THE SUM OF ALL CEMENT PLUS FLYASH AND SLAG. AT THE CONTRACTORS OPTION FLYASH OR SLAG MAY BE SUBSTITUTED FOR CEMENT BUT SHALL NOT EXCEED 25% BY WEIGHT OF TOTAL CEMENTITIOUS MATERIAL IN NO CASE SHALL THE AMOUNT OF FLYASH OR SLAG BE LESS THAN REQUIRED BY THE CONCRETE MIX DESIGN TABLE. FOOTING MIXES SHALL CONTAIN NOT LESS THAN 5 SACKS OF CEMENTITIOUS MATERIAL PER CUBIC YARD, ALL OTHER MIXES SHALL CONTAIN NOT LESS THAN 5-1/2 SACKS OF CEMENTITIOUS MATERIAL PER CUBIC YARD, UNLESS NOTED OTHERWISE. CONCRETE PLACEMENT PLACE CONCRETE FOLLOWING ALL APPLICABLE ACI RECOMMENDATIONS. CONCRETE SHALL BE PROPERLY CONSOLIDATED PER ACI 309 USING INTERIOR MECHANICAL VIBRATORS, DO NOT OVER- VIBRATE. CONCRETE SHALL BE POURED MONOLITHICALLY BETWEEN CONSTRUC11GN OR EXPANSION JOINTS. IF CONCRETE IS PLACED BY THE PUMP METHOD, HORSES SHALL BE PROVIDED TO SUPPORT THE HOSE, THE HOSE SHALL NOT BE ALLOWED TO RIDE ON THE REINFORCING. WEATHER FORECASTS SHALL BE MONITORED AND ACI RECOMMENDATIONS FOR HOT AND COLD WEATHER CONCRETING SHALL BE FOLLOWED AS REQUIRED. CONCRETE SHALL NOT FREE FALL MORE THAN 5 FEET DURING PLACEMENT WITHOUT WRITTEN APPROVAL OF STRUCTURAL ENGINEER. CONTROL AND CONSTRUCTION JOINTS CONSTRUCTION JOINTS SHALL MEET THE REQUIREMENTS OF ACI 301 SECTIONS 2.2.2.5 AND 5.3.2.6. SPECIAL BONDING METHODS PER SECTION 5.3.2.6 SHALL BE SATISFIED BY ITEM 4 BELOW UNLESS OTHERWASE DETAILED ON THE STRUCTURAL DRAWINGS. WHERE CONSTRUCTION JOINTS ARE NOT SHOWN ON PLAN OR ADDITIONAL CONSTRUCTION JOINTS ARE REQUIRED SUBMIT PROPOSED JOINTING FOR STRUCTURAL ENGINEERS APPROVAL. PROVIDE CONSTRUCTION JOINTS AS INDICATED BELOW UNLESS NOTED OTHERWISE ON THE PLANS: 1. SLABS ON GRADE. PROVIDE CONSTRUCTION AND /OR CONTROL JOINTS PER PLAN. COORDINATE JOINTS WIHT ARCHITECTURAL DRAWINGS. EMBEDDED ITEMS 1. NO ALUMINUM ITEMS SHALL BE EMBEDDED IN ANY CONCRETE. 2. ALL EMBED PLATES SHALL BE SECURELY FASTENED IN PLACE. 3. ALL EMBEDDED STEEL ITEMS EXPOSED TO EARTH SHALL BE GALVANIZED. 4. ALL EMBEDDED STEEL ITEMS EXPOSED TO WEATHER SHALL BE PAINTED UNLESS NOTED AS GALVANIZED. SEE DRAWINGS AND SPECIFICATIONS FOR PAINT, PRIMER, AND GALVANIZING REQUIREMENTS. STRUCTURAL DRAWING INDEX 51.00 GENERAL NOTES MIN. AGGREGATE ITEM DESIGN fc (PSI) W/C FOUNDATION DETAILS GRADING (AT 28 DAYS U.N.O.) OR SLAG SLAG RATIN RATIO (PCY) AASHTO SLABS ON GRADE - UNO 4000 0.45 100 57 OR 67 FOUNDATIONS - LINO 3000 0.50 -- 57 OR 67 ALL OTHER CONCRETE 4000 0.50 -- 57 OR 67 CONCRETE PLACEMENT PLACE CONCRETE FOLLOWING ALL APPLICABLE ACI RECOMMENDATIONS. CONCRETE SHALL BE PROPERLY CONSOLIDATED PER ACI 309 USING INTERIOR MECHANICAL VIBRATORS, DO NOT OVER- VIBRATE. CONCRETE SHALL BE POURED MONOLITHICALLY BETWEEN CONSTRUC11GN OR EXPANSION JOINTS. IF CONCRETE IS PLACED BY THE PUMP METHOD, HORSES SHALL BE PROVIDED TO SUPPORT THE HOSE, THE HOSE SHALL NOT BE ALLOWED TO RIDE ON THE REINFORCING. WEATHER FORECASTS SHALL BE MONITORED AND ACI RECOMMENDATIONS FOR HOT AND COLD WEATHER CONCRETING SHALL BE FOLLOWED AS REQUIRED. CONCRETE SHALL NOT FREE FALL MORE THAN 5 FEET DURING PLACEMENT WITHOUT WRITTEN APPROVAL OF STRUCTURAL ENGINEER. CONTROL AND CONSTRUCTION JOINTS CONSTRUCTION JOINTS SHALL MEET THE REQUIREMENTS OF ACI 301 SECTIONS 2.2.2.5 AND 5.3.2.6. SPECIAL BONDING METHODS PER SECTION 5.3.2.6 SHALL BE SATISFIED BY ITEM 4 BELOW UNLESS OTHERWASE DETAILED ON THE STRUCTURAL DRAWINGS. WHERE CONSTRUCTION JOINTS ARE NOT SHOWN ON PLAN OR ADDITIONAL CONSTRUCTION JOINTS ARE REQUIRED SUBMIT PROPOSED JOINTING FOR STRUCTURAL ENGINEERS APPROVAL. PROVIDE CONSTRUCTION JOINTS AS INDICATED BELOW UNLESS NOTED OTHERWISE ON THE PLANS: 1. SLABS ON GRADE. PROVIDE CONSTRUCTION AND /OR CONTROL JOINTS PER PLAN. COORDINATE JOINTS WIHT ARCHITECTURAL DRAWINGS. EMBEDDED ITEMS 1. NO ALUMINUM ITEMS SHALL BE EMBEDDED IN ANY CONCRETE. 2. ALL EMBED PLATES SHALL BE SECURELY FASTENED IN PLACE. 3. ALL EMBEDDED STEEL ITEMS EXPOSED TO EARTH SHALL BE GALVANIZED. 4. ALL EMBEDDED STEEL ITEMS EXPOSED TO WEATHER SHALL BE PAINTED UNLESS NOTED AS GALVANIZED. SEE DRAWINGS AND SPECIFICATIONS FOR PAINT, PRIMER, AND GALVANIZING REQUIREMENTS. STRUCTURAL DRAWING INDEX 51.00 GENERAL NOTES S1.01 GENERAL NOTES S2.00 FOUNDATION PLAN S3.00 FOUNDATION DETAILS Structural Sokrbom 616 wv,r� "asmoe em 8Nt04 Wsehinpou 9610! 7ssora ec_._ som m mom., w..hm�o "ee�m de zss.ae�zr<n Z 0 ry W =3 'oE O U U g o CU_ L Z 0 - Cn - U_ w LLJ 0 O U N r Q Z W w :2 O w Z p � Z 0 w CL Z J W J 0 W i Q J CL J 0 O U ce N Z O Lu O < u U Lli rn LU LLl �C C Z 5 E O CL U <J_ E G � r A. G� srorvsti. Project: 2015 -20 Drawn: BID SET 1 06/29/15 T Sheet S1.00 GROUT NON- SHRINK GROUT: MASTER BUILDERS "MASTERFLOW 555" OR PRE - APPROVED EQUAL. GROUT SHALL CONFORM TO CRD -C621 AND ASTM C1107 WHEN TESTED AT A FLUID CONSISTENCY PER CRD- C611-85 FOR 30 MINUTES. GROUT MAY BE PLACED FROM A 25 SECOND FLOW TO A STIFF PACKING CONSISTENCY. FILL OR PACK ENTIRE SPACE UNDER PLATES OR SHAPES. FOLLOW MANUFACTURER'S RECOMMENDATIONS FOR PREPARATION, INSTALLATION, AND CURING. EPDXY GROUT IN CONCRETE: HILT( HIT -HY 200 MAX -SD OR PRE - APPROVED EQUAL. TWO PART LOW SAG EPDXY. USE EQUIPMENT WHICH WILL ACCURATELY MIX AND DISPENSE THE COMPONENTS. HOLE SHALL BE HAMMER - DRILLED ONLY. HOLE SHALL BE DRY AND CLEANED WITH WIRE BRUSH AND PRESSURIZED AIR JUST PRIOR TO INSTALLING GROUT. THE REBAR OR ROD SHALL BE ROTATED AS IT IS PUSHED INTO THE HOLE. COLD WEATHER GROUTING SHALL BE DONE WITH PROPER GROUT FORMULA. FOLLOW ALL MANUFACTURER'S RECOMMENDATIONS. REINFORCING STEEL REINFORCING STEEL SHALL CONFORM TO: ASTM A615, GRADE 60 TYPICAL UNLESS NOTED OTHERWISE. ASTM A706 GRADE 60 FOR ALL HORIZONTAL BEAM BARS, VERTICAL COLUMN BARS, VERTICAL SHEAR WALL BARS. PER ACI 318, ASTM A615 GRADE 60 MAY BE SUBSTITUTED FOR THESE MEMBERS IF THE ACTUAL YIELD STRENGTH BASED ON MILL TESTS DOES NOT EXCEED THE SPECIFIED YIELD STRENGTH BY MORE THAN 18 KSI AND THE RATIO OF ACTUAL ULTIMATE TENSILE STRENGTH TO ACTUAL YIELD STRENGTH IS NOT LESS THAN 1.25. ASTM A706 GRADE 60 FOR ALL WELDED BARS. DETAIL FABRICATE AND PLACE PER ACI 315 AND ACI 318. REINFORCING SPUCE AND DEVELOPMENT LENGTH SCHEDULE, Fr-60 KSI (UNLESS NOTED OTHERWISE) VERIFICATION AND INSPECTION BAR MINIMUM LAP SPLICE LENGTHS ( "Ls ") MINIMUM DEVELOPMENT LENGTHS ( "Ld ") MINIMUM EMBEDMENT LENGTH FOR SIZE TOP BARS (1) OTHER BARS TOP BARS (1) OTHER BARS STANDARD END HOOKS ( "Ldh ") #3 2' -0" 1' -6" 1' -6" V -3" 0' -7" #4 2' -8" 2' -0" 2' -0" V -7" 0' -9" #5 3' -4" 2' -7" 2' -7" 2' -0" 1' -O" #6 4' -0" 3' -1" S -1" 2' -4" 1' -2" #7 5' -10" 4' -6" 4' -6" 3' -6" 1' -5" #8 6' -8" 1 5 -2" 5' -2" 3' -11" 1' -7" SPLICE TABLE NOTE: 1. "TOP BARS" ARE HORIZONTAL BARS WITH MORE THAN 12" DEPTH OF CONCRETE CAST BELOW THEM. MECHANICAL COUPLERS: "LENTON" BY ERICO, "CADWELD" BY ERICO, "BAR -LOCK" BY DAYTON SUPERIOR L- SERIES, OR PRE - APPROVED EQUAL. COUPLERS SHALL BE TYPE 2 PER ACI 318 SECTION 21.1.6. FORM SAVERS: "LENTON" BY ERICO THREADED FORM SAVERS TYPE FS OR APPROVED EQUAL. REINFORCING STEEL COVER PROVIDE CONCRETE COVER OVER REINFORCEMENT AS FOLLOWS, UNLESS NOTED OTHERWISE. CONCRETE CAST AGAINST EARTH ------ - - - - -- 3" EXPOSED TO WEATHER OR EARTH ------ - - - - -- 2" TIES ON BEAMS AND COLUMNS ------- - - - - -- 1 -1/2" WALLS AND SLABS NOT EXPOSED TO WEATHER - - -- 3/4" AUGERCAST PILES --------------- - - - - -- 2 -1/2" STRUCTURAL STEEL DETAILING. FABRICATION AND ERECTION ALL WORKMANSHIP SHALL CONFORM TO THE AISC MANUAL OF STEEL CONSTRUCTION, 14TH EDITION, THE AISC SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS, JUNE 22, 2010, THE AISC CODE OF STANDARD PRACTICE, APRIL 14, 2010 AND THE AISC SEISMIC PROVISIONS FOR STRUCTURAL STEEL BUILDINGS JUNE 22, 2010. MATERIAL PROPERTIES ANCHOR BOLTS (A.B.): ASTM F1554, GRADE 55. COLD- FORMED STEEL FRAMING CONSTRUCTION: THE DESIGN, INSTALLATION AND CONSTRUCTION OF COLD- FORMED CARBON OR LOW -ALLOY STEEL, STRUCTURAL AND NON- STRUCTURAL STEEL FRAMING, SHALL BE IN ACCORDANCE WITH IBC SECTION 2211 AND AMERICAN IRON AND STEEL INSTITUTE (AISI) STANDARD S100- 07/St -10 AND S200 -07 AND SHALL BE MANUFACTURED BY A MEMBER OF THE STEEL STUD MANUFACTURER'S ASSOCIATION (SSMA), OR PRE - APPROVED EQUAL, IN ACCORDANCE WITH SSMA ICC ER -4943P AND 5200 -07. ALL 54 MIL AND HEAVIER GALVANIZED MEMBERS SHALL BE FORMED FROM STEEL THAT MEETS THE REQUIREMENTS OF ASTM A653, QUALITY SO, GRADE 50, CLASS 1, FY =50 KSI. ALL 43 MIL AND LIGHTER GALVANIZED MEMBERS SHALL BE FORMED FROM STEEL THAT MEETS THE REQUIREMENTS OF ASTM A653, QUALITY SO, GRADE 33, FY =33 KSI. BRIDGING PER MANUFACTURER'S REQUIREMENTS AND AS SHOWN IN THE STRUCTURAL DRAWINGS SHALL BE IN PLACE PRIOR TO PLACING OF ANY CONSTRUCTION LOADS. ALL RUNS SHALL BE RIGIDLY ANCHORED TO END WALLS. MISCELLANEOUS: PRE-ENGINEERED METAL BUILDING THE FOUNDATION DESIGN HAS BEEN BASED ON PRELIMINARY LOAD REACTIONS FROM THE BUILDING COLUMNS. THE FOUNDATION REQUIRES FURTHER COORDINATION AFTER BIDDING ONCE THE MANUFACTURER'S SUBMITTAL IS REVIEWED. COLUMN LOAD SUMMARIES SHALL BE PROVIDED, WHICH COMPILES LOAD COMBINATIONS. THE FOUNDATION SHOULD NOT BE INSTALLED PRIOR TO OUR REVIEW. BUILDING COLUMNS SHALL NOT RELY ON BASE FIXITY WITH THE FOUNDATIONS. REFER TO THE SPECIFICATIONS AND ARCHITECTURAL DRAWINGS FOR ADDITIONAL REQUIREMENTS. LATERAL DRIFT LIMITS AND DEFLECTIONS FOR THE MAIN FRAMES SHALL FOLLOW RECOMMENDATIONS OUTLINED IN AISC DESIGN GUIDE 3 AND MBMA SERVICEABILITY RECOMMENDATIONS WHICHEVER IS MORE STRINGENT. IN NO CASE SHALL LATERAL DRIFT OF MAIN FRAMES EXCEED H /200, CALCULATED IN ACCORDANCE WITH ASCE 7 -10 DESIGN CRITERIA. METAL BUILDING SHALL BE DESIGNED TO SUPPORT EQUIPMENT SHOWN ON MECHANICAL AND ELECTRICAL DRAWINGS. PROVISIONS FOR WALL AND ROOF OPENINGS SHALL BE PROVIDED, SHOP DRAWINGS /SUBMITTALS THE FOLLOWING SHOP DRAWINGS /SUBMITTALS SHALL BE PROVIDED FOR REVIEW AND APPROVAL BY THE STRUCTURAL ENGINEER PRIOR TO FABRICATION OR DELIVERY. STRUCTURAL ENGR. BLDG. DEPT. 1. CONCRETE MIX DESIGNS X X 2. REINFORCING STEEL SHOP DRAWINGS X 3. METAL BUILDING X X 4. CONTRACTOR'S STATEMENT OF RESPONSIBILITY X X SPECIAL INSPECTION: SPECIAL INSPECTION SHALL BE PROVIDED BY AN INDEPENDENT TESTING LABORATORY PER THE REQUIREMENTS OF IBC CHAPTER 17 AND THE LOCAL BUILDING OFFICIAL OR APPLICABLE JURISDICTION AND THE CONTRACT DOCUMENTS. THE SPECIAL INSPECTOR SHALL SUBMIT INSPECTION REPORTS AND A FINAL SIGNED REPORT TO THE BUILDING OFFICIAL FOR THE ITEMS LISTED IN THE QUALITY ASSURANCE /SPECIAL INSPECTION SECTION STATEMENT OF SPECIAL INSPECTIONS: SPECIAL INSPECTION: SPECIAL INSPECTION SHALL BE PROVIDED PER THE REQUIREMENTS OF IBC SECTION 1704 AND AS NOTED HEREIN. STRUCTURAL SYSTEM VERIFICATION AND INSPECTION CONTINUOUS PERIODIC COMMENTS REFERENCES SOILS VERIFY MATERIALS BELOW SHALLOW I IBC 1705.6 FOUNDATIONS ARE ADEQUATE TO ACHIEVE X THE DESIGN BEARING CAPACITY VERIFY EXCAVATIONS ARE EXTENDED TO PROPER X DEPTH AND HAVE REACHED PROPER MATERIAL PERFORM CLASSIFICATION AND TESTING OF X CONTROLLED FILL MATERIALS VERIFY USE OF PROPER MATERIALS, DENSITIES AND LIFT THICKNESSES DURING PLACEMENT AND X COMPACTION OF COMPACTED FILL PRIOR TO PLACEMENT OF COMPACTED FILL, (OBSERVE SUBGRADE AND VERIFY THAT SITE HAS X (BEEN PREPARED PROPERLY CONCRETE REINFORCING STEEL AND PLACEMENT X I ACI 318:3.5,7.1 -7.7 IBC 1910.4 ANCHORS CAST IN CONCRETE -PRIOR TO AND ACI 318: 8.1.3, 21.2.8 DURING PLACEMENT OF CONCRETE IBC 1908.5, 1909.1, X 1705.2.1, AISC 360 SECTION N7 ANCHORS POST - INSTALLED IN HARDENED X ACI 318: 3.8.6, 8.1.3, 21.2.8 CONCRETE IBC 1909.1 VERIFY USE OF REQUIRED DESIGN MIX ACI 318, CH4,5.2 -5.4 X IBC 1904.2, 1910.2, 1910.3 SAMPLING OF FRESH CONCRETE, SLUMP TEST, ASTM C172, C31 AIR CONTENT, TEMPERATURE OF CONCRETE AT X ACI 318:5.6, 5.8 TIME OF MAKING SPECIMENS IBC 1910.10 MAINTENANCE OF SPECIFIED CURING ACI 318:5.11 -5.13 TEMPERATURE AND TECHNIQUES X IBC 1910.9 MATERIAL VERIFICATION OF REINFORCEMENT X MANUFACTURER SHALL PROVIDE IBC 1705.12.1 STEEL FOR ASTM A615 REINFORCING MILL TEST REPORTS COLD- FORMED SCREW ATTACHMENT, WELDING, BOLTING, X IBC 1705.10.2, 1705.11.3 STEEL FRAMING ANCHORING AND FASTENING OF DRAG STRUTS, AWS D1.3 BRACES AND HOLD -DOWNS THAT ARE PART OF THE LATERAL FORCE RESISTING SYSTEM TESTING AND SPECIAL INSPECTION REPORTS SHALL BE PREPARED FOR EACH INSPECTION ITEM ON A DAILY BASIS WHENEVER WORK IS PERFORMED ON THAT ITEM. REPORTS SHALL BE DISTRIBUTED TO OWNER, CONTRACTOR, BUILDING OFFICIAL, ARCHITECT AND STRUCTURAL ENGINEER. STRUCTURAL OBSERVATIONS SHALL BE PERFORMED BY THE STRUCTURAL ENGINEER OF RECORD OR DESIGNATED REPRESENTATIVE IN ACCORDANCE WITH IBC 1704.5. STRUCTURAL OBSERVATION SHALL BE PERFORMED AS FOLLOWS: s PERIODIC VISUAL OBSERVATION OF STRUCTURAL SYSTEMS FOR GENERAL CONFORMANCE TO CONSTRUCTION DOCUMENTS AT SIGNIFICANT CONSTRUCTION STAGES. • REVIEW OF TESTING AND INSPECTION REPORTS. • REPORTS SHALL BE PREPARED FOR EACH SITE VISIT AND SHALL BE DISTRIBUTED TO ARCHITECT. GENERAL CONTRACTOR SHALL SUBMIT A WRITTEN CONTRACTOR'S STATEMENT OF RESPONSIBILITY TO THE BUILDING OFFICIAL AND OWNER PRIOR TO COMMENCEMENT OF WORK. THE CONTRACTOR'S STATEMENT OF RESPONSIBILITY SHALL INCLUDE ACKNOWLEDGMENT OF AWARENESS OF THE SPECIAL INSPECTION REQUIREMENTS CONTAINED IN THE STATEMENT OF SPECIAL INSPECTION. Z $ � J< LU 3 > d O 13 8 Eo U �• Z - 0 _ N U LJi r I O O 2 U N Z LU Cn C < LU J O LU Q 0.z w Z LU J �4 A. S�ONAL in LU N } Q J d J 0 2 U N } Z Q CW O < -C U LU N J � LL •F 0 :) Z E o E (L U CJ E Project: 2015 -20 Drown: BID SET 06 /29/15 li I II Im�I Structural Solutions BllF b ®us, �Im 830 $rte Wuhinnt"n 9.04 1,! Iwora�a,+0000a, sane rot Tmmtwa.niupoa eat@ w m.sa3zre> Shee S1o01 - TYR 5 Typ P FOUNDATION NOTES ----------- — - --- - = -- I. COORDINATE ALL DIMENSIONS WITH ARCHITEGTURAL DRAAIN(55. FINISH FLOOR = 0'-0' A.F.F. UNLESS NOTED OTHERWISE. fP4.0 F5.0 � F,.O I 2."- ' INDICATES CONCRETE THIGKEKED SLAB. 5EE3/53.00. I H 3. "F2 INDICATES GONGRETE SPREAD FTC. SEE 4/53.00. 4. 1 INDIGATE5 STEEL COLUMN PER PRE - ENGINEERED METAL BUILDING 4" COW- SLAB ON MANUFACTURER. GRADE H/ EA #4 WAY AT H1 . 5. BUILDING COLUMNS SHALL NOT RELY ON BASE FIXITY. NO COLUMN 15" O.C. tI I MOMENTS SHALL BE TRANSFERRED INTO THE FOUNDATION. 6. METAL BUILDING MANUFACTURER SHALL PROVIDE LOAD COMBINATION SUMMARY FOR ALL COLUMNS. SAW CUT SLAB JOINT5 TYR - SEE /-2-\ '7. FOUNDATION REQUIREMENTS AT MAIN FRAMES AND PORTAL FRAME-5 BAYS SHALL BE VERIFIED AFTER METAL BUILDING DRAWINGS AND cALUILATIoN5 ARE SUBMITTED AND REVIEWED. DO NOT PROCEED WITH ANY FOUNDATION FABRICATION OR WORK UNTIL A FINAL SUBMITTED BY P05 STRUCTURAL SOLUTIONS. TYP. n! ly .00, 1 TYP. AT CMD5r-J L-1 BUILDING DATA B- - - - - - - - 1. PRE - ENGINEERED METAL BUILDING. �-y - - - - - - - - - - - - - -- - - - - -- - -- F4.0 - 2. FRAME EAVE HEIGHT = IT-O'. 2--O"y F5.0 T4.0 I 3. ROOF SLOPE = 3:12, 1 4. MAIN MOMENT FRAMES LOCATED ON GRIDS 4� , 4 4 FROM GRID A TO B. 2--0-!/ 5. PORTAL FRAMES LOCATED ON GRIDS A 4 0 BETWEEN GRIDS 2 4 5. (D C. FOUNDATION PLAN 2.00 /5,=1 -C', Sim. 2--0- z LU E > F 6 2 0 E o 0 U AIM � • U 1 2: 0 V) U LU 0 0 rY z z < LU 11 J :� - LU z 0 z 0 z CIL 0 LL. S A. 0 LU r C/) CL -J 0 0 r U F- :z 0 C U LU LU C) n z 0 0 CL U E (D Project: 201,5-20 BID SEf 06/29/15 SIM Structural Sohidow S2.00 E GO ; PIPE -- FT6 GONG. BAGKFILL PARALLEL BELOW FTC TO WALL -- #, GR055 TIE BAR T 8 BEARING 5011-5 - I I EXCAVATION HIDTH OF H/ 180° BEND PER .00 .00 SEE 6EN. NOTES PERMITTED BELOW FT6 MIN. SECTION PRIOR TO LOADING I" =1'-O" TYPICAL FOR PARALLEL PIPES ADJACENT TO FOOTING ao NOTES: STAKE THREADS I. FOUNDATIONS SHALL NOT BE LOADED PRIOR TO COMPLETING In" STRUCTURAL BAGKFILL UNDER f NEAR FOOTINGS. �l 2. CONCRETE BAGKFILL SHALL BE USED UNDER FOOTIN65 HHERE GRADE A 45% COMPACTION CANNOT BE ACGOMPLI5HED. HEAVY HEX 3. ALL STRUCTURAL BACKFILL NOTED SHALL BE COMPACTED TO STRUCTURAL BAGKFILL 95% OF MAX. DENSITY PER A5TM. WITHIN (2) TIMES THE 4. A PIPE SLEEVE SHALL BE PROVIDED FOR 5HALLON PIPES CAST TRENCH DEPTH EA. IN CONCRETE. 51DE OF FT6 5. PIPES SHALL NOT BE PLACED IN THE FOOTING HITHOUT SPECIFIC APPROVAL FROM THE ENGINEER. 6, FOR VARIATIONS CONTACT ENGINEER. TYPICAL FOR PERPENDICULAR PIPES UNDER FOOTINGS rl,�\ SECTION .00 NO 50ALE 1/8" SAW-,UT x 14" - SAW WITHIN 4 TO 6 HOURS OF POURING 5LA13 - FILL W/ MASTIC. -) GLR --GUT EVERY OTHER BAR AT SANGUT TYPICAL CONTROL JOINT FOR SLAB ON GRADE 2 SECTION 3.00 NO 5GALE 5TL COL. BY — PER MTL BLDG MFR BLD6 MFR -- ¢ COL. BASE R GONT. THIGKENED d SPREAD FT6 ED6E BEYOND -T SLEEVE FOR — CONCRETE COVER PER m DOWNSPOUT INHERE APPLICABLE ANCHOR BOLTS j SPECIFIED BY BLDG CONT. REINF. MFR - VERIFY N15H GRADE QUANTITY t LAYOUT FI 3/4" NON - SHRINK GROUT I rW GLR SLAB ; -- -- - - - - -- -- o0 'I II f I I I 3/4"0 A301 THREADED ROD o 24" O.G. IN PRE - DRILLED HOLES DBL NUT TYP. Zp (V 2 NUT EA. 51 DE OF HEB TYPI I ¢ OF MAIN FRAME GOL d CONC. DOVER #3 TIES V 0 12" O.G. 2'• e J' (12) #5 VERT. - EPDXY EMBED 8" INTO GONG. FRAME GHAMFER PER ARCH. ¢ OF MAIN FRAME COL. f GONG. COVER ® SLOPE TOP OF CONG.GOVER PER ARCH. PLAN 3.00 1 ° =1' -0" GONST. JT PLINTH VERT. , DO N✓EL5 PER e m CONC. SPREAD FT6 F4.0 -- #, GR055 TIE BAR T 8 BEARING 5011-5 - 14” (4) #5 TOP d BOT. H/ 180° BEND PER .00 .00 SEE 6EN. NOTES r5 SECTION .00 I" =1'-O" 3/4"0 A301 THREADED ROD o 24" O.G. IN PRE - DRILLED HOLES DBL NUT TYP. Zp (V 2 NUT EA. 51 DE OF HEB TYPI I ¢ OF MAIN FRAME GOL d CONC. DOVER #3 TIES V 0 12" O.G. 2'• e J' (12) #5 VERT. - EPDXY EMBED 8" INTO GONG. FRAME GHAMFER PER ARCH. ¢ OF MAIN FRAME COL. f GONG. COVER ® SLOPE TOP OF CONG.GOVER PER ARCH. PLAN 3.00 1 ° =1' -0" (2) I TYP. THICKENED 5LA13 ED6E r5--� SECTION 3.00 I" =1' -0" REINF. 'H' (FA. WAY) (EVENLY SPACED) -- 2" GLR -j 2' GLR. 3" GLR. b" MAX. TYP. 5ECTION MARK AB• .D. (SIMILAR AT 5/8 "d 12' F4.0 3/4'0 15° 14” (4) #5 TOP d BOT. I'm IB" fo 16" (5) #5 TOP 6 BOT. ~ z F A5TM A30, Qz GRADE G OR FI554 6RADE 36 6i o JL� STAKE THREADS CORNERS OF PLINTH In" ASTM FD44 \ —A5TM A563 CARBON FLAT GRADE A HASHER TYP. J HEAVY HEX TYPICAL AT BUILDING COLUMN FOUNDATION PLINTH REBAR GAGE WIT TYP. TYPICAL ANCHOR BOT END .00 NO 5GALE DETAIL 3.00 NO 51-ALE (2) I TYP. THICKENED 5LA13 ED6E r5--� SECTION 3.00 I" =1' -0" REINF. 'H' (FA. WAY) (EVENLY SPACED) -- 2" GLR -j 2' GLR. 3" GLR. b" MAX. TYP. 5ECTION MARK DIMENSIONS REINF. EA. WAY TOP t (SIMILAR AT „W „:: BOTTOM F4.0 4' -0' 14” (4) #5 TOP d BOT. F5.0 5' -0" 16" (5) #5 TOP 6 BOT. NOTES: I. CENTER ALL FOOTINGS ON COLUMN BASE PLATE ABOVE EXCEPT AS SHORN OTHERWISE. 2. FOOTINGS SHALL BEAR ON UNDISTURBED OR COMPACTED MATERIAL, SEE GENERAL NOTES. TYPICAL CONCRETE SPREAD FOOTING DETAILS r SECTION 3.00 NO SCALE ¢ COL. Vr DIR BASE IP BASE IE LIREGTION j VARIES #1 U BAR N/ BAR - LOCK COUPLER M9;Z �g 5LA5 EDGE m c j c _ (SIMILAR AT INTERIOR A.B5 -- W/O SLAB _ _ _ #3 PLINTH TIES - - -- EDGE) (3) 5ET5 0 2' O.G. GLR FROM TOP OF 5LA13 E (1) SET #b PLINTH VERT5 - AT o 2" ABOVE CORNERS OF PLINTH BOTTOM OF A.B. TIES E o 6" O.G. MAX. EA. 51DE 51MILAR H/ SLAB ED6E ON (2) 51DE5 TYPICAL AT BUILDING COLUMN FOUNDATION PLINTH REBAR GAGE PLAN SECTION .00 NO 5GALE JOINT FLOOR SLAB TOP OF--J • • L (2) #, CONT. N/ FOOTING BAR - LOCK GONG. TIE COUPLERS BEAM 5" 8' S" SECTION 3.00 NO SCALE W E3 i d O f� 052 U �m ` 5= Z N U W . 0 O N tie J Q Fa W W tJ Z Lu Op r- Z 0 0 z 0 LL 0 W N Q IL I O U Cie Z0 W O -C i2 U Lu J h t LU C r Z E E CL U J_ 1= } yl 9IONAL Project: 2015 -20 Drown; ail BID SET 06/29/15 ma CK11 esl Structural Solwwns S3.00 . 1}50 P.eGCA�mm, 6Wa'!Ol n®aw.wm�° "ens ELECT CAL LEGEND SYMBOL DESCRIPTION WITH DRAWINGS AND SPECIFICATIONS. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED IN THE PRESENCE OF THE ENGINEER. A COMPLETE REPORT OF TEST PROCEDURE AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER, LIGHTING FIXTURE SCHEDULE SURFACE MOUNT LIGHT FIXTURE aDG DUPLEX RECEPTACLE (G INDICATES GROUND FAULT CIRCUIT INTERRUPTER) V W MOUNTING AND REMARKS DEDICATED CONDUIT HOMERUN TO PANEL & CIRCUIT NUMBERS AS INDICATED ON PLANS VANDAL RESISTANT LINEAR FIXTURE FAIL —SAFE (2) F32 T8 RACEWAY CONCEALED IN WALL OR CEILING i RACEWAY CONCEALED UNDERGROUND OR UNDER FLOOR SLAB _ MARKS INDICATE NUMBER OF #12 AWG UNLESS NOTED OTHERWISE PROVIDE WITH WIREGUARD GROUNDING CONDUCTOR INDICATES A CONDUIT STUBBING UP — EXISTING 208/120 VOLT PANELBOARD $T TIMER SWITCH U CONSTRUCTION NOTES W W INDICATES WEATHERPROOF FOR ALL DEVICES, PROVIDE LOCKING COVER ON RECEPTACLES. GENERAL NOTES (APPLY TO ALL DRAWINGS) 1. SEE EACH DRAWING FOR ADDITIONAL GENERAL NOTES THAT ARE SPECIFIC TO AN AREA OR DRAWING. 2. PRIOR TO BIDDING THE CONTRACTOR /INSTALLING VENDOR IS RESPONSIBLE TO VERIFY ALL CMU /CONCRETE WALLS, BRICK WALLS, EXISTING UNDERGROUND CONDUIT CAPACITIES, CABLE ROUTING AND ALL WORK REQUIRED TO FACILITATE A COMPLETE AND FULLY FUNCTIONAL SYSTEM. ALL WALLS SHALL BE CORE DRILLED AS REQUIRED. 3. PROVIDE CORE DRILLING AS REQUIRED TO ACCOMMODATE NEW WORK. CORE DRILLED HOLES CAN NOT PENETRATE THROUGH ANY EXISTING REBAR AND CONDUIT CONTAINED IN THE EXISTING CONCRETE SLAB OR WALLS. CORE DRILL LOCATIONS MAY NEED TO BE MODIFIED TO ACCOMMODATE EXISTING OBSTRUCTIONS CONTAINED WITHIN THE FLOOR OR WALL. NEVER CORE DRILL A STRUCTURAL BEAM OR MODIFY THE STRUCTURAL INTEGRITY OF THE BUILDING. PROVIDE WEATHERPROOF SEALANT AROUND ALL CONDUIT PENETRATIONS THROUGH EXTERIOR WALLS. 4. ALL JUNCTION BOXES SHALL BE SIZED PER NEC, UNLESS A LARGER SIZE IS IDENTIFIED ON THE PLANS. PROVIDE SECURITY SCREWS FOR JUNCTION BOXES LOCATED IN AREAS THAT ARE EXPOSED TO THE PUBLIC, STUDENTS, OR SCHOOL STAFF. 5. E.C. TO PROVIDE SAWCUT OF ASPHALT, BACKFILL, COMPACTING AND ASPHALT PATCHING. & ONLY BRANCH CIRCUIT HOMERUNS ARE SHOWN WITH NUMBER OF CONDUCTORS /WIRES. E.C. SHALL PROVIDE ALL REQUIRED CONDUCTORS /WIRES TO ALL DEVICES AS NECESSARY IN ORDER TO INSTALL ALL CIRCUITS, SWITCHING AND GROUNDING COMPLETE. PANEL CIRCUIT NUMBERS ARE SHOWN TO CLARIFY CIRCUITING CONFIGURATION. CONDUCTOR HASH MARKS ARE NOT SHOWN FOR #12 WIRE, #10 NEUTRALS SWITCH LEGS OR GROUNDING CONDUCTORS BETWEEN DEVICES. GENERAL NOTES FOR LIGHTING FIXTURE SCHEDULE 1. FOR LIGHTING CONTROLS WHICH INCLUDE DAYLIGHT OCCUPANCY SENSORS AND TIME CLOCK CONTROLS, THE ELECTRICAL CONTRACTOR SHALL PROVIDE TESTING OF THE CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS TO MAKE SURE THEY ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE WITH DRAWINGS AND SPECIFICATIONS. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED IN THE PRESENCE OF THE ENGINEER. A COMPLETE REPORT OF TEST PROCEDURE AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER, LIGHTING FIXTURE SCHEDULE SYMBOL FIXTURE DESCRIPTION MANUFACTURER /MODEL # LAMPS V W MOUNTING AND REMARKS SF1 VANDAL RESISTANT LINEAR FIXTURE FAIL —SAFE (2) F32 T8 120 59 MOUNT TO UNDERSIDE OF STRUCTURE, WITH INTEGRAL OCCUPANCY SENSOR HVLB- 232— UNV- 0— EB82— S —OS —WG 4000K PROVIDE WITH WIREGUARD Z Lu > O O(n V a U m Z 0 U_ LLl 0 W W = J N O Q W J r H 0 x U N LL. V) Q 0 L1 Z 0 ~ _ H N LLJ L Z U LLI to W I J t LL 1 C Q Oz Z E 72 � C O w �u LLU Z E W LLu (� SIONAL Project: 2015-20 Drawn: O.C. BID SET - 06/29/15 Sheet E0.01 70 0 EDGE OF PAVEMENT \ 5 - / Q GENERAL NOTES j // ¢ i v 1. REFER TO E2.0 FOR PLAYSHED DETAIL. \ 2. PRIOR TO BID THE CONTRACTOR IS RESPONSIBLE TO / E2.0 / \\ \ / / / VERIFY & PROVIDE ALL ASPHALT CUTTING /PATCHING NEEDED FOR CONDUIT ROUTING. PROPOSED LOCATION / 3. ALL TRENCHING IS TO MEET NEC REQUIREMENTS. --Of PLAYSHEO ` \j / / 4. ALL UNDERGROUND CONDUIT IS TO BE PVC SCHEDULE j/� sw W 40 CONDUIT OR APPROVED EQUAL. \ rl I i I i 1 I is I � I I BI I' I s� 1 \ e / y \ 5 : \ \ / j/5. ALL CONDUIT ABOVE GRADE AND SUBJECT TO WEATHER / OR DAMAGE IS TO BE RIGID METAL CONDUIT. /j 5. ALL CONDUIT IN THE INTERIOR OF BUILDING IS TO BE EMT METAL CONDUIT AND FOLLOW BUILDING LINES IN � A NEAT WORKMANLIKE MANNER. 7. WORK PERFORMED ON ENERGIZED EQUIPMENT IS TO / FOLLOW THE STANDARDS STATED IN NFPA 70E. PVC \ �� i (3) #8 THHN f / \ PROVIDE 1° PVC CONDUIT SPARE %F BETWEEN BUILDING\ AND PLAYSHED� w STUB CONDUIT UP BUILDING AND CORE DRILL % / THROUGH EXTERIOR WALL AT CEILING HEIGHT \ OF ELECTRICAL ROOM a PANEL C / V - ,-/-30, 4W, 208/120V � 100A, MLO V \\ Al /, \� CONSTRUCTION NOTES `p 0 TERMINATE CONDUCTORS ON SPARE 20A BREAKER � 0 1 LOCATED IN PANEL C. n ELECTRICAL SITE PLAN � 16 0 15' 32 SCALE: 1/15"=l'-O" SCALE. 1!15 "= '.' -0" Z c �3 s'' 0 u� E� U sI? my m 0 Q' Lii FA Q 11 w V) Q u w w Q CL Q 0 0 U cn Z0 LL, 0 L u U Lu N J w o= Z E 00 Ji E 2} .PEL L. CO Fecr9rvsee �`„ �ssroyei �`�. bl \5i�' Project: 2015 -20 Drawn: O.C. BID SET 06/29/15 Sheet E1.0 U — n PLAYSHED ELECTRICAL PLAN U SCALE: 1/8`" = 1'-0, C -10 GENERAL NOTES 1. ALL CONDUITS SHALL BE ROUTED ALONG STRUCTURE OR PERPENDICULAR IN A NEAT WORKMANLIKE MANNER. CONSTRUCTION NOTES Q1 PROVIDE A 0 -50 MINUTE TIMER SWITCH IN A NEMA 4 BOX, HINGED COVER AND WING KNOB LATCH. PROVIDE MOUNTING PANEL FOR SWITCH BOX. MOUNT SWITCH AT +50" ABOVE FINISHED GRADE. Q2 COORDINATE ROUTING OF CONDUIT WITH STRUCTURE. Q3 MOUNT RECEPTACLE TO I —BEAM AT +24" ABOVE FINISHED GRADE WITH 1 -5/8" UNISTRUT AND APPROVED BEAM CLAMPS. Z Lu > O U 'm Z 0 N _ U_ W Z r) W_ c� N Q � p � w CL Z _J ZD 0 Z U z N C Q Q Q w Z o U p W� pe w u U L a w p w Lu w 0 w = E 0 N O E V) _J U w Q Z _� E ii � r N� 9T6Aw' SyVN Fess(ONAL �G} I� Project: 2015 -20 Drawn: O.C. BID SET 1 06/29/15 mr- Shee: E2.00