Loading...
20150272 Permit Pkg 08132015City of Yelm Community Development Department Building Division Phone: (360) 458 -8407 Fax: (360) 458 -3144 Applicant: Name: SOUNDBUILT NW LLC Address: PO BOX 73790 PUYALLUP WA 98373 Property Information: Site Address: 9961 DOTSON ST SE Assessor Parcel No.: 78640100870 Contractor Information: Name: SOUNDBUILT NW LLC Address: PO BOX 73790 PUYALLUP WA 98373 Contractor License No.: Project Information: Project: NEW RESIDENTIAL BUILDING Description of Work: LOT 87, PLAN 285389 Sq. Ft. per floor: First 1063 Second 1322 Third Garage 591 Basement Fees: Item NEW RESIDENTIAL BUILDING MECHANICAL PLUMBING Subdivision Permit No.: 20150272 Issue Date: 8/13/2015 (Work must be completed within 180 days) Phone: 253 - 848 -0820 Owner: SOUNDBUILD NW LLC TAHOMA TERRA Lot: 87 Expires: Phone: 0 /00 /0000 Heat Type (Electric, Gas, Other): GAS Contractor Fees SOUNDBUILT NW LLC $17,758.66 SOUND HEATING & AC $ 84.75 RAINIER VIEW ROOTER, LLC $ 139.00 TOTAL FEES: $ 17,982.41 Applicant's Affidavit: I certify that I have read and examined the information contained within the application and know the same to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of Yelm regulations including those governing zoning and land subdivision, and in addition, all covenants, easements and restrictions of record. If apply g as a contractor, I further certify that I am currently registered in the S ate of Was in ton. Signature A Date Firm OFFICIAL USE ONLY # Sets of Prints: Final Inspection: Date: By: City of Yelm (36 ) 458 -3244 REC #: 00204016 OPER: CO TERM REF #: 5423 PAID BY: 8/13/2015 10:33 AM 001 TRAN: 33.0000 BUILDING PERMITS 20150272 17,982.41CR SOUNDBUILT NW LLC 9961 DOTSON ST SE BLD -RES1 17,758.66CR MECH 84.75CR PL 139.000R TENDERED: 17,982.41 CHECK APPLIED: 17,982.41- CHANGE: 0.00 w1m. 1� M W � CITY OF YELM RESIDENTIAL BUILDING PERMIT APPLICATION FORM Project Address: 9961 Dotson St SE Parcel #: 78640100870 Subdivision: TahomaTerra Lot #: 87 Plan #: 2-e3—J U f Zoning: ED New Construction ❑ Re -Model / Re -Roof / Addition ❑ Home Occupation Sign El Plumbing ❑ Mechanical ❑ Mobile / Manufactured Home Placement ❑ Other Project Description /Scope of Work: construct SFR using plan 2853A Project Value: Building Area (sq. ft) 1st Floor 1063 2nd Floor 1322 3rd Floor Garage -2 car 3 car 591 Covered Patio 126 Covered Porch 186 Patio Deck # Bedrooms 4 # Bathrooms 2_5 Heating: GAS /OTHE r ELECTRIC (Circle One) Are there any environmentally sensitive areas located on the parcel? If yes, a completed environmental checklist must accompany permit application. BUILDING OWNER NAME: Soundbuilt Homes ADDRESS PO Box 73790 EMAIL meganp @soundbuilthomes.com CITY Puyallup STATE WA ZIP 98373 TELEPHONE 253 -848 -0820 ARCHITECT /ENGINEER Landmark Design /sega Engineers LICENSE # Eng -26606 ( Greg Thesencitz) ADDRESS 1202 Main St #104 EMAIL kevin @landmarkplans.com CITY Sumner STATE WA ZIP 98390 TELEPHONE 253 - 626-7808 GENERAL CONTRACTOR Soundbuilt Homes TELEPHONE 253 -848 -0820 ADDRESS PO Box 73790 EMAIL meganp @soundbuilthomes.com CITY Puyallup STATE WA ZIP 98373 FAX n/a CONTRACTOR'S LICENSE # SOUNDNL911cL EXP DATE 2117 CITY LICENSE # PLUMBING CONTRACTOR Rainier view RooterLLc TELEPHONE 253 -435 -1996 ADDRESS PO Box 73070 EMAIL CITY Puyallup STATE WA ZIP 98373 FAX CONTRACTOR'S LICENSE # RAINIVR942DF EXP DATE 3116 CITY LICENSE # MECHANICAL CONTRACTOR sound Heating & Ac TELEPHONE 253 -875 -3350 ADDRESS 5526184th St E #A EMAIL CITY Puyallup STATE WA ZIP 98375 FAX CONTRACTOR'S LICENSE # SOUNDHAOO6DA EXP DATE 5/17/14 CITY LICENSE # Copy of mitigation agreement with Yelm Community Schools, if applicable. I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above described property will be in accordance with the laws, rules and regulations of the State of Washington and the City of Yelm. Applicant's (Sig na re Owner / Co tractor Owner's Agent / C I Date Agent (Please circle one.) All permits are non- transferable and will expire if work authorized by such permit is not begun within 180 days of issuance, or if work is suspended or abandoned for a period of 180 days C� AUG 0 3 2015 105 Yelm Avenue West (360) 458 -3835 Yelm, WA 98597 (360) 458 -3144 FAX = J www.ci.yelm.wa.us REPRINT YELM COMMUNITY SCHOOLS PO BOX 476 YELM WA 98597 Receipt #: 308675 Manual #: 7/29/2015 2:57 PM Clerk: ZIGLER Terminal: 1 NSOUNDBUILT NSOUNDBUILT SOUND BUILT NW LLC, HOMES PO BOX 73790 PUYALLUP, WA 98373 -0790 Qty Item 1 CPF MITIGATION 3015.00 MITIGATION Tahoma Terra # 68 9908 Jensen DR Yelm CPF MITIGATION MITIGATION 3015.00 Tahoma Terra # 87 9961 Dotson ST Yelm Subtotal 6030.00 Tax 0.00 Total 6030.00 Check 6030.00 5300 Change Due 0.00 THANK YOU O 00 0t, n 0 o �4 - u_i O W 0 - --i U L/-) o O LM L- Z o Q1 `. lD OQ o3 W _ .+ \� c _ E ml ca LU U = CY) a CL co o c I I � U it Z CDC - ommo c` � [Q naves I x z W Ln O IE 5 OO ��a< o3d — v 03dA0 O Q W Y { co W LN Z (n W H _ 2 N m ! O N LA M f Oi 3 W V) i N CC i i C W Q o V ,'V m ( N Gj LLJ LLI L J z m'" S: II 3 J II L� J N CG p� i C? € Z �W D xU a t � � °o�oo cn W i U D: Q � PORCH 000 I V1� ry W H r% co Zw O] O O¢Q z uu UP �o(,() 00 ° ~� o ° I LL °LI 00 NIVM 3415 0 00 ° Z O Z d aQO° �J °1) z u� ww 0 Q- CL Z ¢ c ° z � 19 NOS1Oa }- Z cV U � SC -740 TECHNICAL SPECIFICATION NTS r- 90.7" (2304 mm) ACTUAL LENGTH I 12. m (310 mm) 85.4" (2169 mm) INSTALLED LENGTH « BUILD ROW IN THIS DIRECTION ACCEPTS 4" (100 mm) SCH 40 PVC PIPE FOR INSPECTION PORT. FOR PIPE SIZES LARGER THAN 4" (100 mm) UP TO 10" (250 mm) USE INSERTA TEE CONNECTION CENTERED ON A CHAMBER CREST CORRUGATION l N Ro oo db OVERLAP NEXT CHAMBER HERE (OVER SMALL CORRUGATION) n n 30.0" (762 mm) 51.0" (1295 mm) START END NOMINAL CHAMBER SPECIFICATIONS SIZE (W X H X INSTALLED LENGTH) 51.0" X 30.0" X 85.4" (1295 mm X 762 mm X 2169 mm) CHAMBER STORAGE 45.9 CUBIC FEET (1.30 m') MINIMUM INSTALLED STORAGE` 74.9 CUBIC FEET (2.12 m') WEIGHT 75.0 lbs. (33.6 kg) 'ASSUMES 6" (152 mm) STONE ABOVE. BELOW, AND BETWEEN CHAMBERS A j` A 1 B � STUBS AT BOTTOM OF END CAP FOR PART NUMBERS ENDING WITH "B" C STUBS AT TOP OF END CAP FOR PART NUMBERS ENDING WITH "T" ?,e of PART # STUB A B C SC740EPE06T / SC740EPE06TPC 6" (150 mm) 10.9" (277 mm) 18.9'(470 mm) SC740EPE06B / SC740EPE06BPC -- " (13 mm 0.5 ) SC740EPE08T /SC740EPE08TPC 8° (200 mm) 12.2" (310 mm) 16.5" (419 mm) - SC740EPE08B / SC740EPE08BPC - 0.6" (15 mm) SC740EPE10T / SC740EPE10TPC 10" (250 mm) 13.4" (340 mm) 14.5" (368 mm) - SC740EPE10B / SC740EPEI OBPC -- 0.7" (18 mm) SC740EPE12T I SC740EPE12TPC 12" (300 mm) 14.7" (373 mm) 12.5" (318 mm) -- SC740EPE12B / SC740EPE128PC -- 1.2'(30 mm) SC740EPEI5T / SC740EPE15TPC 15"(375 mm) 18.4" (467 mm) 9.0" (229 mm) -- SC740EPE15B / SC740EPE15BPC - 1.3" (33 mm) SC740EPE18T / SC740EPE18TPC 18" (450 mm) 19.7" (500 mm) I 5.0" (127 mm) - SC740EPE18B / SC740EPE18BPC I -- 1.6"(41 mm) SC740EPE246' 24" (600 mm) 1 18.5" (470 mm) I - 0.1" (3 mm) ALL STUBS, EXCEPT FOR THE SC740EPE24B ARE PLACED AT BOTTOM OF END CAP SUCH THAT THE OUTSIDE DIAMETER OF THE STUB IS FLUSH WITH THE BOTTOM OF THE END CAP. FOR ADDITIONAL INFORMATION CONTACT STORMTECH AT 1- 888 - 892 -2694. FOR THE SC740EPE24B THE 24" (600 mm) STUB LIES BELOW THE BOTTOM OF THE END CAP APPROXIMATELY 1.75"(44 mm). BACKFILL MATERIAL SHOULD BE REMOVED FROM BELOW THE N -12 STUB SO THAT THE FITTING SITS LEVEL. NOTE: ALL DIMENSIONS ARE NOMINAL Duct Leakage Affidavit (New Construction) Permiil#: House address or lot number:, City: LA Zip: Cond. Floor rea A ft2 :` . ( ) Source (circle one): Plans Estimated Measured ❑ Duct tightness testing is not required. The total leakage test is not required for ducts and air handlers located entirely withiri' the building thermal envelope. Ducts located in crawl spaces do not.qualif,- for this exception. Air Handler in conditioned space? ❑ yes) Air Handler present during test? yes ❑ no Circle Test Method: Leakage to Outside Total Leakage Maximum duct. leakage: Post Construction, total duct leakage: (floor area x.04) = CFM @25 Pa Post Construction, leakage to outdoors: (floor area x :04).= CFM @25 Pa Rough -In, total duct leakage with air handler installed: (floor area x.04) = / t CFM @25 Pa Rough -in, total duct leakage with air handler not installed: (floor area x.03) = CFM @25 Pa Test Result: - CFM @25Pa Ring (circle one if applicable): Open 2 3 Duct Tester Location: Pressure Tap Location: Lin- I certify that these duct leakage rates are accurate and determined using standard duct testing protocol. Company Name:�,j� }- j Technician: Technician Signature Date: --� Phone Number: S 5- 3 3SO & AIr CondManing-c. Property Address: 2_2 Date: l �' Conditioned Floor Area: Builder or registered design professional: Signature: e Ceiling: Vaulted R- Floors Over unconditioned space R -_ Attic R- Slab on grade floor R -_ Walls: Above Grade R- Doors R-- Below, int. R R -- Below, ext R R-_ • r � a ks R U `factarssat� ,SKG Q €may ���ed�r�. MK': '. w: d?'R� NFRC rating (or) Windows U- SHGC Defa u It R a ting(chapter 10 WSEC 2009) Skylights U- SHGC- e System Type Efficiency Heating C s Cooling D t 1 W (> � g , All ducts & HVAC in conditioned space (yetis no Insulation R- ® Test Method: _Total Leakage Leakage to exterior r Handler present Test Target CFM @25Pa Test Results @25Pa � G�CFM Building air leakage target: ACHso<5.0 - Tested leakage: ACH50 =__ L _ Building Address City of Yelm Community Deuelopment Department Residential Certificate of Occupancy 9961 DOTSON ST SE Owner Name SOUNDBUILT NW LLC Owner Address PO BOX 73790 PUYALLUP WA 98373 Building Permit Number 20150272 Remarks: LOT 87, PLAN 2853139 Areas Inspected Special Conditions Building Official ALL CODE REQUIRED & CARLSON Plan Number 2853139 Date: January 14, 2016 This structure is in compliance with the International Residential Code (Chapter 51 -51 WAC) as adopted by the Washington State Building Code Council pursuant to Chapters 19.27 and 70.92 RCW, effective July 1, 2004