20150275 Permit Pkt 08172015City of Yelm
Community Development Department
Building Division
Phone: (360) 458 -8407
Fax: (360) 458 -3144
Applicant:
Name: MYKLAND CONSTRUCTION LLC
Address: 6121 85TH AVE W
UNIVERSITY PLACE WA 98467
Property Information:
Site Address: 1 AA11 1 nnTH AVF SF
Assessor Parcel No.: 78640111300
Contractor Information:
Name: MYKLAND CONSTRUCTION LLC
Address: JASON MYKLAND
6121 85TH AVE W
UNIVERSITY PLACE WA 98467
Contractor License No.: 11001
Permit No.: 20150275
Issue Date: 8117/2015
(Work must be completed within 180 days)
Phone:
Owner: MYKLAND CONTRUCTION
Subdivision: TAHOMA TERRA Lot: 113
Expires:
Phone:
12/31/2015
Project Information:
Project: NEW RESIDENTIAL BUILDING
Description of Work: LOT 113, PLAN 1361
Sq. Ft. per floor: First 925 Heat Type (Electric, Gas, Other): GAS
Second 436
Third
Garage 331
Basement
Fees:
Item
NEW RESIDENTIAL BUILDING
MECHANICAL
PLUMBING
Contractor
MYKLAND CONSTRUCTION LLC
SOUND HEATING & AC
PUGET SOUND MECHANICAL, INC.
TOTAL FEES:
Applicant's Affidavit:
I certify that I have read and examined the information contained within the application and know the same
to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of
Yelm regulations including those governing zoning and land subdivision, and in addition, all covenants,
easements and restrictions of record. If applying as a contractor, I further certify that I am currently
registered in the S e of Washington.
%•
Signature v Datel' I J
Firm
Fees
$16,716.95
$ 84.75
$ 111.00
$ 16,912.70
OFFICIAL USE ONLY
# Sets of Prints:
Final Inspection:
Date:
By:
City of Yelm
(36 ) 458 -3244
REC #: 00204594
OPER: CO TERM:
REF #: 2381
PAID BY:
8/17/2015 10:40 AM
001
IRAN: 33.0000 BUILDING PERMITS
20150275 16,912.70CR
MYKLAND CONSTRUCTION LLC
14411 100TH AVE SE
BLD -RES1 16,716.95CR
MECH 84.75CR
PL 111.000R
TENDERED: 16,912.70 CHECK
APPLIED: 16,912.70-
CHANGE: 0.00
YELM COMMUNITY 476 HOOLS
po BOX YELM WA 98597
Receipt #: 308755 Clerk: Croy
Terminal: 1
Manual #'.
8/17/2015 10:32 AM
NMYKLAND, JASON
NMYKLAND, JASON
MYKLAND, JASON
6121 85TH AVE W.
UNIVERSITY PLACE, WA 98467
Price
Uty Item
Cp�MIT 1 ION
3015.00
MITIGATION
3015.00
1 CPF MITIGATION
MITIGATION
Subtotal
6030.00
0.00
Tax
Total
6030.00
Debit /Credit
6030,00
Change Due
0.00
THANK YOU
��0aT5
CITY OF YELM
RESIDENTIAL BUILDING PERMIT APPLICATION FORM
Project Address: / LILY ( l � 0,,)C C Parcel #: 78 b'� G � �
Subdivision:70��LOw0, i` Lot #: i I Plan #: I Zoning: Res'ciev�hK�
New Construction Re -Model / Re -Roof / Addition Home Occupation Sign
Plumbing Mechanical Mobile / Manufactured Home Placement Other
Project Description /Scope of Work: ✓1 (f L�-' S e ^ ' ! `� 11� ✓�tH
Project Valufl ��
Building Area (sq. ft) 1" Floor 2nd Floorq-�� Garage Deck
Basement Carport Patio
# Bedrooms_ # Bathrooms_ Heatin� /OTHER or ELECTRIC (Circle One)
Are there any environmentally sensitive areas located on the parcel?
If yes, a completed environmental checklist must accompany permit application.
BUILDING OWNER NAME:--J`t .V n V'I j��nc
ADDRESS b I1�-- \ q �5� IC, �;J EMAIL -_! yn'/
CITY STATEtvti ZIP Cif l7 TELEPHONE a53 - -'�
ARCHITECT /ENGINEER LICENSE #
ADDRESS EMAIL
CITY STATE ZIP TELEPHONE
GENERAL CONTRACTOR W\ TELEPHONEz��'-S
ADDRESS 6(Z( K5 " a,. ./' EMAIL.iAI` K> c. —L— '^")..
CITYU✓i1derC% 7 a, STATE,,.,, ZIP c�, b7 FAX
CONTRACTOR'S LICENSE # EXP DATE -CITY LICENSE #
PLUMBING CONTRACTOR �Igf S `1 e` "' TELEPHONE , -�3 -3 7 ,00
ADDRESS EMAIL
CITY STATE ZIP FAX
CONTRACTOR'S LICENSE EXP DATE CITY LICENSE #
MECHANICAL CONTRACTOR_S-o l a TELEPHONE
ADDRESS EMAIL
CITY STATE ZIP FAX
CONTRACTOR'S LICENSE # EXP DATE CITY LICENSE #
Copy of mitigation agreement with Yelm Community Schools, if applicable.
I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the
above described property will be in accordance with the laws, rules and regulations of the State of Washington and the
City of Yelm.
pp cant's Signature Date
O ner / Contractor / Owner's Agent / Contractor's Agent (Please circle one.)
All permits are non - transferable and will expire if work authorized by such permit is not begun
within 180 days of issuance, or if work is suspended or abandoned for a period of 180 days
�,JG IO 2015
105 Yelm Avenue West (360) 458 -3835
Yelm, WA 98597 (360) 458 -3144 FAX
www.ci.yelm.wa.us
THOMA TERRA- PH.2- DIV.1
LOT- 113
{.) Y
I OOTM AVE SE
SIDE WALK CURB
S'E - " .�� - -- EET TREE
pL¢ g T 2" CAL. MIN.
ic)
I
CV
Ci
ofYolm
C®
pp
A roved ^;
P Zj
(n
IMPERVIOUS AREA
DRIVEWA
ROOF= 7459 S.F.
Y 8c
SIDEWALK= 258 S.F.
TOTAL= 1717 S.F.
LOT S. F. = 3562
9' -1, PORCH
I
1►
II
II
I I
II
I!
(I
I;
ROOF
DRAINS
W
j O
10"
1�I
136119-1
ELE . -A IIj�I
2 -S WRY I) '
�I�)I
24' II!II
^inn
I
II °�
GARAGE I�
.`I I
5 -.1 - -8" ' DRYNELL
i C.O. PER
THURSTON Y
COUNTY `j'
- — — _;_. — — " -, — STANDARD r
LOCKWOOD LANE SE
NOTES:
1. FRONT PORCH FOUNDATION AND STEP
TANK LOCATION SHALL BE STAKED OUT
FOR SET BACK INSPECTION.
2. STEP TANK IN VIOLATION OF THE REQUIRED
5' MINIMUM SETBACK TO FOUNDATION
SHALL BE BACK FILLED WITH CDF.
3. CONNECT PVC ROOF DRAINS TO DRYWELL.
CONTACT INFO
JASON: (253) 686 -4633
KeC!eJ"'ed s// a /,j;-
MYKLAND
CONSTRUCTION
L.L.C.
6121 85TH AVE, W.
UNIVERSITY PLACE, WA.
98467
PH- (253) 686 -4633
T I
2' MINIMUM SETBACK
BETWEEN SIDEWALKS,
DRIVEWAYS, EASEMENTS,
AND STEP TANK.
THURSTON COUNTY
14411 100th Ave. SE.
Yelm, WA 98597
PARCEL# 78640111300
PZ 08/11/15 R1.0
January 8, 2015
City of Yelm — Building Department
105 Yelm Ave W.
Yelm, WA 98597
RE: Jason Mykland of Mykland Construction — Use of Base Plan — Tahoma Terra
To Whom It May Concern:
Soundbuilt Northwest is giving permission to Jason Mykland or Mykland Construction the use of our
approved base plan for the 1361 and the 1437 plan with the City of Yelm.
Please call Angela Warner with any questions regarding this letter. Her contact number is 253 - 830 -2868.
Sincerely,
bar q-
Gary Racd
President
Soundbuilt Northwest, LLC
AUG 2015
P.O. Box 73790, Puyallup, WA 98373 ■ Phone: (253) 848 -0820
Prescriptive Energy Code Compliance for Climate Zones 6,5 and Marine 4
Contact Information
P�e�mm�ewn
This project will use the requirements of the Prescriptive Path below and incorporate the
the minimum values listed. In addition, based on the size of the structure, the appropriate
number of additional credits are chocked as chosen by the permit applicant.
Authorized Representative Date
Wood Frame Wall"
Mass Wall R-Value'
Floor
Below Grade Wall`�
Efficient Building Envelope 1 a
0,5
lb
Efficient Building Envelope 1 b
1.0
1c
Efficient Building Envelope 1c
2,0
2a
Air Leakage Control and Efficient Ventilation 2a
0,5
2b
Air Leakage Control and Efficient Ventilation 2b
1.0
2c
Air Leakage Control and Efficient Ventilation 2c
15
3a
High Efficiency HVAC 3a
0,5
21 int
0,056
21+5ci
0.044
21/2 1 n
0.056
214,5'
0.044
30g
O029
301
O029
10115/21 int + TB
0,042
10/15121 int + TB
O042
Efficient Water Heating
1.5
6
lRenewable Electric Energy
.Table R4021.1 and Table R402.13 Footnotes included on Page 2.
Each dwelling unit in one and two-family dwellings and townhouses, as defined in Section 101.2 of the
International Residential Code shall comply with sufficient options from Table R406.2 so as to achieve the
following minimum number of credits:
[]`. Small Dwelling Unit: 0.5 points
�
Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of
�
fenestration area. Additions to existing building that are less than 750 square feet of heated floor area,
�2 2. Medium Dwelling Unit: 1.5 points
All dwelling units that are not included in #1 or #3, including additions over 750 square feet,
1-13. Large Dwelling Unit: 2.5 points
Dwelling units exceeding 5000 square feet of conditioned floor area,
Table R406.2 Summary
n_4.~_ n=,rinti=,
rdr--rsff W.
_
la
Efficient Building Envelope 1 a
0,5
lb
Efficient Building Envelope 1 b
1.0
1c
Efficient Building Envelope 1c
2,0
2a
Air Leakage Control and Efficient Ventilation 2a
0,5
2b
Air Leakage Control and Efficient Ventilation 2b
1.0
2c
Air Leakage Control and Efficient Ventilation 2c
15
3a
High Efficiency HVAC 3a
0,5
3b
High Efficiency HVAC 3b
1,0
3c
High Efficiency HVAC 3c
2O
3d
High Efficiency HVAC 3d
1'0
4
High Efficiency HVAC Distribution System
1,0
5a
Efficient Water Heating
0.5
5b
Efficient Water Heating
1.5
6
lRenewable Electric Energy
0,5
Total Credits
*Please refer to Table R406.2 for complete option descriptions
1�5
OU
AUG 10 2015
Table R402.1.1 Footnotes
For Sk 1 foot = 304.8 mm, ci = continuous insulation, int .= intermediate framin&
3 R-values are minimums, Vactors and SHGC are maximums, When insulation is installed in a cavity which is
less than the label or design thickness of the insulation, the compressed R-value of the insulation from
Appendix Table A101.4 shall not be less than the R-value specified in the table.
b The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration
Exception: Skylights may be excluded from glazed fenestration SHGC requirements in Climate Zones 1
through 3 where the SHGC for such skylights does not exceed 0.30.
c "10/15/21.+TB" means R-10 continuous insulation on the exterior of the wall, or R-15 on the continuous
insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the
be permitted to be met with R-13
basement wall at the interior of the basement wall. "10/15/21+TB" shall
cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or
exterior of the wall. "10/13" means R-10 continuous insulation on the interior or exterior of the home or R-
13 cavity insulation at the interior of the basement wall. "TB" means thermal break between floor slab and
basement wall,
d R-10 continuous insulation is required under heated slab on grade floors. See 11402.2.9.1
e There are no SHGC requirements in the Marine Zone.
f Basement wall insulation is not required in warm-humid locations as defined by Figure R301.1 and Table
1, Reserved.
h First value is cavity insulation, second is continuous insulation or insulated siding, so "13,+5" means R-13
cavity insulation plus R-5 continuous insulation or insulated siding. if structural sheathing covers 40 percent
or less of the exterior, continuous insulation R-value shall be permitted to be reduced by no more than R-3
in the locations where structural sheathing is used to maintain a consistent total sheathing thickness.
The second R-value applies when more than half the insulation is on the interior of the mass wall.
For single rafter- or joist-vaulted ceilings, the insulation may be reduced to R-38.
k int. (intermediate framing) denotes standard framing 16 inches on center with headers insulated with a
minimum of R-10 insulation.
I Log and solid timber walls with a minimum average thickness of 3.5 inches are exempt from this insulation
requirement
Table R402.1.3 Footnote
a Nonfenestration U-factors shall be obtained from measurement, calculation or an approved source or as
specified in Section R402,1.3.
Glazing Schedule
Project Information Confect fnformetlon
1361
Vertical Glazing (Windows and glazed doors)
Plan Component Glazing
ItU L)escripIion
t<eT. U-TaCI9r
B�
LIVING ROOM
2
0.30
LIVING ROOM
sue,
1
0.30
MASTED BEDROOM
1
0,30
DINING ROOM
#
1
0.30
KITCHEN
0.30
a
MSTR BATH
11
2
0.30
MSTR BEDROOM
1
0.30
1
BEDROOM 2
1
0.30
BEDROOM 3
1
0.30
STAIR
1
0.30
14
3
0,30
12
0.30
##
# ##
0.30
0.30
0.30
0.30
8402.3.3 Exception {15 sq. it. max.} 15
Width Height
Qt. Feet "'ch Feet I=tch
Glazing
Area UA
B�
2
2
4
sue,
1
4
4�
1
4
4
#
1
5
4
a
MI ##
11
2
2
3
1
2
1
2
1
5
4
1
4
4
1
4
14
3
2
12
##
# ##
Glazing
Area UA
• i
sue,
#
# #
# rt #
MI ##
# ##
##
# ##
Sum of Area and UA
Area Weighted U = UAVArea
amm�**;
�U:7�
Simple Heating System Size: Washington State
Requirements of the 2012 Washinalon State Energy C24t(WLSEC) and ACCA
Manuals
Lo—ac[q-
The glazing (window) and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of
0,30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC,
Please fill out all of the green drop-downs and boxes that are applicable to your project. As you make selections in the drop-downs for each section,
some values will be calculated for you. If you do not see the selection you need in the drop-down options, please call the WSU Energy Extension
Program at (360) 956-2042 for assistance,
�rqjecr Information Cci,nact lnforrrallon
11361
Heating System Type: Forced Ar Furnate 0 Heat Pump
70 see detailed instructions for each section, piace your cursor on the word 'Instructions'
Design Temperature
Instructions I ------ Design Temperature Difference (AT) 41
Tacoma CO w t'ldoor ,170 degrees; ou=or Design remp
Area of Building
Conditioned Floor Area
instructions Conditioned Floor Area (sq ft)
Average Ceiling Height
Instructions Average Ceiling Height (f*)
Glazing and Doors
Instructions
Insulation
Conditioned Volume
Attie
12,249
8,444
U-Factor
Single Rafter or Joist Vaulted Callings
UA
Instructions
S410a A-valkw
V
Above Grade Walls
U-Factor
X Area
UA
Floors
925
Instructions
U-Factor
Area
UA
Below Grade
Building and Duct Heat Load
instructions . ..... . ..
Wed 01114"
V
Slab Below Grade P Nv
UA
Sdert __)"Onkv
•
Slab on Grade (.",A
U-Factor
Instructions
Sawa 12 -vaka
UA
Location of Ducts
925
Instructions
U-Factor
Area
UA
77
Duct Leakage Coefficient
1,10
Sum ofUA
Conditioned Volume
12,249
8,444
U-Factor
X Area
UA
0,30
160 7 , 7
48,00
U-Factor
X Area
UA
0026
925
24,05
U-Factor
Area
UA
No selection;
Building and Duct Heat Load
15,254
U-Factor
Area
UA
0,056
1,912
107.07
U-Factor
Area
UA
0.029
925
2683
U-Factor
Area
UA
No selection
1:=
---
F-Factor
Length
UA
No selection
- --
F- Factor
Lenqth
UA
cr selection
---
Duct Leakage Coefficient
1,10
Sum ofUA
205,95
Envelope Heat Load
8,444
Stu I Hour
Sum ofUA,X,NT
Air Leakage Heat Load
5,424
Stu / Hour
voiurriex 26)(ATX 018
Building Design Heat Load
13.868
Btu / Hour
Air Leakage - EnveOPe Heat Loss
Building and Duct Heat Load
15,254
Btu I Hour
nuctsm uncor
�Nnned space Sam of Sudoing Heat LOSS X
to
'Ducts A, COPUIMIAOd sP$Ce SUM Of Solding Heat LOSS X 1
Maximum Heat Equipment Output
21,356
Btu / Hour
awIdmg and Duct Heat Loss X 1 40 for Forced AirPurrace
811,,'0119 and Duct Hear Loss X 1,25 lot Heal Pump
(07101113)