Loading...
20150281 Permit Pkg 08272015City of Yelm Community Development Department Building Division Phone: (360) 458 -8407 Fax: (360) 458 -3144 Applicant: Name: MILTON W BUTLER Address: 14630 BERRY VLY RD SE YELM WA 98597 Property Information: Site Address: 109 MOSMAN AVE SE Assessor Parcel No.: 22719331300 Contractor Information: Name: MILTON W BUTLER Address: 14630 BERRY VLY RD SE YELM WA 98597 Contractor License No.: Project Information: Project: RESIDENTIAL ADDITION Description of Work: 8FT x 24FT ADDITION Sq. Ft. per floor: F. i rst Second Third Garage Basement Fees: Item BUILDING Permit No.: 20150281 Issue Date: 8/2712015 (Work must be completed within 180 days) Phone: 360- 458 -5420 Owner: JAKE BUTLER Subdivision: Lot: Phone: Expires: 0 /00 /0000 Heat Type (Electric, Gas, Other): Contractor MILTON W BUTLER TOTAL FEES: Applicant's Affidavit: I certify that I have read and examined the information contained within the application and know the same to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of Yelm regulations including those governing zoning and land subdivision, and in addition, all covenants, easements and restrictions of record. If applying as a contractor, I further certify that I am currently registered in.the "Sfa of Washington. Signatures TIC C�`( Date , - �S Firm Fees $ 303.56 $ 303.56 OFFICIAL USE ONLY # Sets of Prints: Final Inspection: Date: By: City of Mm (36 ) 458 -3244 REC #: 00205382 8;27/2015 2:10 PM OPER: CO TERM: 001 REF #: 7084 PAID BY: TRAN: 33.0000 BUILDING PERMITS 20150281 303.56CR BUTLER, MILTON W 109 MOSMAN AVE SE BLDG 303.56CR TENDERED: 303.56 CHECK APPLIED: 303.56 - CHANGE: 0.00 Z01607-01 CITY OF YELM RESIDENTIAL BUILDING PERMIT APPLICATION FORM Project Address: ailS aVe.Z_ Parcel #: �d 7-- 19 � Subdivision: Lot #: Plan #: Zoning: New Construction X Re -Model / Re -Roof / Addition Home Occupation Sign Plumbing Mechanical !_, Mobile, / Manufactured Home Placement Other Project Description /Scope of Work: Project Value: `p>n Building Area (sq. ft) 1s` Floor I9A 2nd Floor Garage Deck Basement Carport Patio # Bedrooms_ # Bathrooms_ Heating: GAS /OTHER or ELECTRIC (Circle One) Are there any environmentally sensitive areas located on the parcel? —O If yes, a completed environmental checklist must accompany permit application. BUILDING OWNER NAME: 4 2 ADDRESS 1 30 &#U VWfii EMAIL CITY S ATE IAIA ZIP TELEPHONE - j6070 ARCHITECT /ENGINEER LICENSE # ADDRESS EMAIL CITY STATE ZIP TELEPHONE GENERAL CONTRACTOR TELEPHONE ADDRESS EMAIL CITY STATE ZIP FAX CONTRACTOR'S LICENSE # EXP DATE CITY LICENSE # PLUMBING CONTRACTOR TELEPHONE ADDRESS EMAIL CITY STATE ZIP FAX CONTRACTOR'S LICENSE # EXP DATE CITY LICENSE # MECHANICAL CONTRACTOR TELEPHONE ADDRESS EMAIL CITY STATE ZIP FAX CONTRACTOR'S LICENSE # EXP DATE CITY LICENSE # Copy of mitigation agreement with Yelm Community Schools, if applicable. I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above described property will be in accordance with the laws, rules and regulations of the State of Washington and the City of Yelm. Applicant's Signature Dat Owner / Contractor / Owner's Agent / Contractor's Agent (Please circle one.) 9/0 All permits are non - transferable and will expire if work authorized by such permit is not begun within 180 days of issuance, or if work is suspended or abandoned for a period of 180 days , �o j] AUG 2 e 2015 105 Yelm Avenue West Yelm, WA 98597 www.ci.yelm.w¢.us (360) 458 -3835 -= (360) 458 -3144 FAX a < 2 ni Guu�' ti t !oo _ k � '� �_ • -- -- - �-- � -- ' - + -- r - --, -' - � tail if window See .. de � - -� � -�-- I is less then 2'-8 -- ' from __ _. AB 6 foot on center a -± - - - wall end R _ 21 in new I # 44 each end of j I I _a existing na I footing _ { _i _.._•.� _. ._t _ ' �._._; -_ - ( i j ' 4 s i in existing 4 inch slab 6 mil vapor ath i- barrier I — r-- .�.y_...._.. 7 , .�. _ ...._.�. . ......... ..._ _. _ .. ... ! I R -49 in attic i _ f � L See detail for footing and r - - I ! insulation I i I f I Smoke alarm typical FT t a < 2 ni Guu�' ti cz M 1-4 veb,) v- R- 10 insulation for 2 feet at new addition. At existing from bottom of footing to bottom of slab EXTENT OF HEADER SINGLE PORTAL FRAME (ONE BRACED WALL PANEL) MIN. 3" X 11.25" NET HEADER 1 ------------ 6' TO 18' L FASTEN TOP PLATE TO HEADER WITH TWO TYPICAL PORTAL ROWS OF 16D SINKER NAILS AT 3" O.C. TYR 1000 LB FRAME STRAP CONSTRUCTION 1000 LB STRAP OPPOSITE SHEATHING FOR A PANEL SPLICE FASTEN SHEATHING TO HEADER WITH 8D COMMON OR (IF NEEDED), PANEL GALVANIZED BOX NAILS IN 3" GRID PATTERN AS SHOWN AND EDGES SHALL BE EIGHT 3" O.C. IN ALL FRAMING (STUDS, BLOCKING, AND SILLS) TYP. BLOCKED, AND OCCUR WITHIN 24" OF MID- HEIGHT ONE ROW OF MIN. WIDTH = 16" FOR ONE STORY STRUCTURES TYP. SHEATHING-TO- MIN. WIDTH = 24" FOR USE IN THE FIRST OF TWO FRAMING NAILING IS STORY STRUCTURES REQUIRED. MIN. 2.4 FRAMING +: IF 2X4 BLOCKING IS MIN. USED, THE 2X4'S MUST 3/8" MIN. THICKNESS WOOD DOUBLE 1�1 BE NAILED TOGETHER STRUCTURAL PANEL SHEATHING 2x4 POST WITH 3 160 SINKERS MIN. 4200 LB TIE-DOWN DEVICE (EMBEDDED INTO CONCRETE AND NAILED INTO FRAMING) MIN 1000 LB TIE DOWN SEE SECTION 2308.9.3.2 DEVICE inch = 25.4 mm; I pound = 4.448 Detail 1 ALTERNATE BRACED WALL PANEL ADJACENT TO A DOOR OR WINDOW OPENING