Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
20150309 Permit Pkg 10132015
o� City of Yelm q Community Development Department 4 Building Division Phone: (360) 458 -8407 Fax: (360) 458 -3144 Applicant: Name: YELM CHIROPRACTIC & WELLNESS Address: 715 YELM AVE E YELM WA 98597 Property Information: Site Address: 71r, YFI M AVF F A Assessor Parcel No.: 22730120102 Subdivision: Contractor Information: Name: MECHANICAL & CONTROL SERVICES, Address: JOEL 6426 18TH ST E FIFE WA 98424 Contractor License No.: MECHACS962BT Expires Permit No.: 20150309 Issue Date: 10/13/2015 (Work must be completed within 180 days) Phone: Owner: COUNTRY PLAZA. LLC Phone: 2/26/2016 Project Information: Project: MECHANICAL Description of Work: REPLACE HVAC PACKAGE UNIT WITH NEW 60000 BTU UNIT Sq. Ft. per floor: First Heat Type (Electric, Gas, Other): Second Third Garage Basement Fees: Item MECHANICAL Contractor YELM CHIROPRACTIC & WELLNESS TOTAL FEES: ELECTRIC Applicant's Affidavit: I certify that I have read and examined the information contained within the application and know the same to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of Yelm regulations including those governing zoning and land subdivision, and in addition, all covenants, easements and restrictions of record. If applyin as a contractor, I further certify that I am currently registered in the State_o4Nashjpgton/f��J Signature ' /_j' _ Date // ) //J( //N:-- Firm ' Lot: Fees $ 33.25 $ 33.25 OFFICIAL USE ONLY # Sets of Prints: Final Inspection: Date: By: Cifj of Yelm (36 ) 458-3244 REC #: 00209776 10/13/2015 OPER: CO 4:04 PM REF #: 27756 TERM: 001 PAID BY: TRAN: 33.0000 BUILDING PERMITS 20150309 YELM CHIROPRACTIC '& SCR 715 YELM AVE E 5 WELLNESS MECH 33.25CR TENDERED: APPLIED: 33.25 CHECK 33.25_ CHANGE: �``-- ----- 0.00 CITY OF YELM COMMERCIAL BUILDING PERMIT APPLICATION FORM gg0007467 300 Project Address: "7t-5 EA 4&eA q-yt~ 5TE 5 Parcel #:—Z t-1301 Z 01 o Z. Zoning; Current Use: Proposed Use: New Constructiog Re -Model / Re -Roof / Tenant Improvement Plumbing Mechanical Fire Prevent/Suppress /Alarm Other Project Description /Scope of Work: REPLACE �1) P-oo F-TOP HVPK_ uN t'1" Project Value: 9, 24$, ®eC Building Area (sq. ft) Parking Garage 1" Floor 2nd Floor 3rd Floor Building Height 40 I Are there any environmentally sensitive areas located on the parcel? If yes, a completed environmental checklist must accompany permit application. BUILDING OWNER/TENANT NAME: YELwt GHie0Ae#9cT /c.. f t,JEeLNC S S ADDRESS its E'A. vet-OA StAlre 5 EMAIL CITY YELwl, STATE W ZIPS$' 7 TELEPHONE 3(c0- '/S'8 °22 ARCHITECT /ENGINEER LICENSE # ADDRESS EMAIL CITY STATE ZIP TELEPHONE GENERAL CONTRACTOR TELEPHONE ADDRESS EMAIL CITY STATE ZIP FAX CONTRACTOR'S LICENSE # EXP DATE CITY LICENSE # PLUMBING CONTRACTOR TELEPHONE ADDRESS EMAIL CITY STATE ZIP FAX CONTRACTOR'S LICENSE # EXP DATE CITY LICENSE # MECHANICAL CONTRACTORn1KNAn /cAt- &oVr e_ TELEPHONE 253 =92(0- '7?? ADDRESS N26 18'7H ST E, EMAIL 1-06 S ado Vws Cave CITY F Fe- - STATE W�9 ZIP WI/ FAX CONTRACTOR'S LICENSE # EXP DATE CITY LICENSE # Copy of City Mitigation documentation ITFCI, z- Lfe- /f0 certify that the above information is correct and that the construction on, and the occupancy and the use of the _scribed property will be in accordance with the laws, rules and regulations of the State of Washington and the k Signature Date �ntractor / Owner's Agent / Contractor's Agent / Tenant (Please circle one.) All permits are non - transferable and will expire if work authorized by such permit is not begun within 180 days of issuance, or if work is suspended or abandoned for a period of 180 days 105 Yelan Aue W Yedan, WA g� 98597 A •,�" C P OCT 0 2 2015 (360) 458 -3835 (360) 458 -3144 FAX cu w co. c i.ye Ina. uua. us aK;b Structural Solutions Seattle 811 First Avenue, Suite 620 • Seattle, WA 98104 • tel: 206.292.5076 Tacoma 1250 Pacific Avenue, Suite 701 • Tacoma, WA 98402 • tel: 253.383.2797 www.pcs-structural com STRUCTURAL CALCULATIONS FOR COUNTRY PLAZA ROOF TOP SUPPORT 715 EAST YELM AVENUE, SUITE 5 YELM, YVASHINGTON PREPARED BY PC5 STRUCTURAL 5OL.UT/ON5 ,,nil l.'� r l �., 42292 �:.z 40IZ{ I� OCTOBER 20 2015 16 -022 C (CS d O O L m O O 9 C j r� Lll r[f w F- a a 0 a 00 w o u J + w - Ln o m W z w 0 W z O "o O N N C O Q.� QJ wr-� Q o g F- z w N O 1 w u�� N Full Perimeter Roof Mounting Curb 1 1/2 Figure 4. 4042 — 4060 Models BAYCURB051A Full Perimeter Roof Mounting Curb r r � A D I i I CHANNEL END —! i I �c 38 8 14 SERVICE CLEARANCE DIMENSIONS A The drawings on this page are prepared by the C manufacturer in order to provide detail regarding WC */TC* job layout only. These drawings are not intended to 36.00 be used as a basis to construct, build or modify the 24.00 items depicted in the drawings. The manufacturer \ is not responsible for the unauthorized use of these 12.00 ** drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 53 a � i C4 — CHANNEL SIDE WOOD NAILER ** 42.00 WITH ECONOMIZER WITH 25% FRESH AIR ACCESSORY 4YCC4042A- SUB -1 B -E N SERVICE CLEARANCE DIMENSIONS A B C D WC */TC* 42.00 36.00 12.00 ** 24.00 DC * /YC* 42.00 36.00 12.00 ** 1 36.00 ** 42.00 WITH ECONOMIZER WITH 25% FRESH AIR ACCESSORY 4YCC4042A- SUB -1 B -E N Product Specifications MODEL 4YCC4042A1060A 4YCC4042AI090A RATED Volts /PH /Hz 208- 230/1/60 208 - 230/1/60 Performance Cooling CONSTANTTORQUE ECM BTU (a) 40500 40500 Indoor Airflow (CFM) 1450 1450 Power Input (KW) 3.4 3.4 EER /SEER (BTU /Watt- 12.0/14.00 12.0/14.00 Hr.) 208 - 230/1/60 208- 230/1/60 Sound Power Rating 6 6 [dB(A)] (b) 74.6 74.6 PERFORMANCE DIRECT/ 1 DIRECT/ 1 HEATING(c) 1/34/3345 1/34/3075 Input BTUH -1st Stage 230/1/60 230/1/60 (Natural Gas) (v) 60000 90000 AFUE 81 81 Temp. Rise — Min /Max 30/60 35/65 ( °F) 5.3 5.3 Orifice Qty/Drill Sz Z / #37 3 / #37 (Natural Gas) 7.3 7.3 POWER CONN. —V 208- 230/1/60 208 - 230/1/60 Ph /Hz 10° 10° Min. Brch. Cir. 1/2 1/2 Ampacity (e) 28,5 28,5 Fuse Size — Max. 45 45 (amps) Fuse Size — Recrri 45 45 (amps) COMPRESSOR SCROLL SCROLL VOLTS /PH /HZ 208- 230/1/60 208- 230/1/60 R.L. Amps — L.R. 16.7/109.0 16.7/109.0 Am s OU DOOR COIL— SPINE -FIN SPINE -FIN P Rows /F.P.I 2/24 2 / 24 Face Area (sq.ft.) 15,63 15.63 Tube Size (in.) 3/8 3/8 INDOOR TYPE MCHE MCHE Rows /F.P.I 2/16 2 / 16 Face Area (sq.ft.) 3.9 3.9 Tube Size Width (in.) .81 .81 Refrigeration Control EXPANSION VALVE EXPANSION VALVE Drain Conn. Size (in.) 3/4 FEMALE NPT 3/4 FEMALE NPT OUTDOOR FAN— TYPE SWEPT SWEPT DIA. (IN.) 28,25 28.25 DRIVE /NO. SPEEDS DIRECT/ 1 DIRECT/ 1 CFM @ 0.0 in. w.g. Y) 3400 3400 Motor — HP /R.P.M 1/4/825 1/4/825 4YCC4042A -SUB -1 6-EN Volts /Ph /Hz 208 - 230/1/60 208 - 230/1/60 F.L. Amps /L.R Amps 1.51/3.07 1.51/3.07 INDOOR FAN — TYPE CONSTANT TOR UEECM CONSTANTTORQUE ECM Dia. x Width (in.) 10.62 X 10.62 10.62 X 10.62 Drive /No. Speeds DIRECT/ 3 DIRECT / 3 CFM @ 0.0 in. w.g. (9) SEE FAN PERF TABLE SEE FAN PERF TABLE Motor— HP /R.P.M. 3/4/1050 3/4/1050 Volts /Ph /Hz 208 - 230/1/60 208- 230/1/60 F. L. Amps 6 6 COMBUSTION FAN — TYPE CENTRIFUGAL CENTRIFUGAL Drive /No. Speeds DIRECT/ 1 DIRECT/ 1 Motor — HP /R.P.M. 1/34/3345 1/34/3075 Volts /Ph /Hz 230/1/60 230/1/60 FLA .20 .24 FILTER / FURNISHED NO NO Type Recommended THROWAWAY THROWAWAY Recmd. Face Area (sq. ft ) (h) 5.3 5.3 REFRIGERANT R -410 R -410 Charge (lbs.) 7.3 7.3 CHARGING SPECIFICATIONS Subcooling 10° 10° GAS PIPE SIZE (in.) 1/2 1/2 DIMENSIONS H X D X W H X D X W Crated (in.) 46 X 47 X 62 46 X47 X 62 WEIGHT Shipping (lbs.) / Net (lbs.) 555/ 452 561(457 (a) Rated in accordance with AHRI Standard 210 /240.itHR1- rAen9Vrd rating conditions are: 80 D.B.67 W.B. entering air to indoor coil. 95 D. B. entering air to outdoor coil. (b) Sound Power values are not adjusted for AHRI 270 -9S tonal corrections. (0 Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per 1000 ft. elevation, (d) Convertible to LPG. W This value is approximate. For more precise value, see Unit Nameplate. (r) Standard Air — Dry Coil — Outdoor. (g) Based on U.S. Government Standard Tests. (h) Filters must be installed in return air stream. Square footages listed are based on 300 f,p.m, face velocity, If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C. I Figure 2. 4YCC4042 --4060 Outline Drawings 372.82 [14-11/161 (OUTSIDE) + 58.19 . - _;_, [2.9/321 RETURN 322 84 112- 23/321 449.02 [li•II /I6] 19 50 (OUTSIDE] [3 1/81 449.02 7 176.07 [17-11/161 E6-15/161 (OUTSIDE) BACK DUCT OPENINGS 1402.34 155-7/32] (SURFACE AREA) BACK SIDE ) 181 Model Height mm /In Approx. Comer Weight - kg / Ibs Shipping Weight kg /Ibs Total Unit Weight kg /Ibs Center of Gravity mm /in A W1 W2 W3 W4 e C 4YCC4042 (060) 898.53 [35 -3/8] 71.2 (157] 46.6 [103] 34.6 [761 53 -1 [1171 252.2 [5551 202.0 [4521 470.0 [18.5] 731.0 [20.8] 4YCC4042 (090) 898.53 [35 -3/81 71.8 1158] 47.2 [104] 35.2 [781 53.6 11183 254.5 [5611 207.3 (4571 470.0 [18.5] 731.0 [28.8] 4YCC4048 (070) 1000.13 (39 -3/81 71-4 [1571 44.6 (98] 33.2 (731 53.9 [1191 250.3 [5521 202.1 (4481 433.0 [17.01 743.3 (29.31 4YCC4048 (090) 1000.13 [39 -3/8j 72.0 [1591 4S.0 (991 33.8 (75] 1 54.4 (120) 252.6 [5571 205.4 [453] 1 433.0 (17.0) 743.3 (29.3] 4YCC4060 (090} 1000.13 [39 -3/81 77, 1 [170) 45.8 (1011 34.4 (76) 1 58.3 [1281 263.1 [580] 215.9 [476) 433.0 [17.0) 743.3 [29.3] 4YCC4060 (115) 100013 (39 -3 {81 78.0 (1721 46.3 (102] 34.9 [77) 1 59.0 [1301 265.8 [5861 218.6 [482] 41.4.0 (16.3) 635.0 [25.01 4YCC4042A- SUB -18 -EN ADAPTER CURB 5 ADAPTER CURB FOR 2 /4TC */WC *NC *3042 -060A 38 7/8" -"'� �. 531181, 12" 61 3/4" ' 'I ~ R/A 35" I INSTRUCTIONS: 1. REMOVE OLDA/C UNIT. 2. APPLY 1/4" x 1 1/4" GASKETING. 3. INSTALL & SECURE ADAPTER CURB ON EXISTING CURB AS REQUIRED BY LOCAL BUILDING CODE, 4. APPLY 1/4" x 1 14" GASKETING ON ADAPTER CURB. 5. INSTALL & SECURE NEW A/C UNIT ON ADAPTER CURB AS REQUIRED BY LOCAL BUILDING CODE. EXISTING, TRANE UNIT YCC036FH & YCC042FM YCCO48FM STANDARD FEATURES: • HEAVY GA. GALV. STEEL CONSTRUCTION • FULLY INSULATED WITH 1" - 1.5 LB. DENSITY INSULATION • 1/4!'x 1 1/4" GASKETING • SHIPPED FULLY ASSEMBLED • SUPPLY AND RETURN DUCT CHAMBERS INCLUDED PRODUCT SUBMITTAL QUOTE # ' Signature required prior to production. TC51ACTC45 Manufacturers Equip. Sign Here: I Approved Date PCS Structural Solutions Job Number= 16 -022 Date = 2- Oct -15 Name = LAH I Project = Country Plaza - Roof Top Unit Replacement - Yelm, Washington Design Criteria = ASCE 7 -10, IBC 2012 Unit Weight, Wp = 811 lb Existing Unit Weight= unkoowA 4 �b Roof Dead = Actual Roof Live = 25 psf C,j rb + 10ako + PV (O Lateral Analysis: The new unit does not have a significant impact to the building's capacity to resist wind or seismic forces Check Seismic Forces (Ultimate): ASCE 7 Eq 13.3 -1 Fp= 0.4 *SDS *(Ip /Rp) *ap *Wp *[1 +2 *z /h] = 374 1 ASCE 7 Eq 13.3 -2 Fp max = 1.6 *SDS *lp *Wp = 1298 lb ASCE 7 Eq 13.3 -3 Fpmin = 0.3 *Sps *lp *Wp = 243 lb SAS = 1 ASCE 7, Table 13.6 -1 ap = 2.5 ASCE 7, Sec. 13.1.3 Ip = 1 ASCE 7, Table 13.6 -1 RP = 6.5 height of attachment z = 25.0 ft total of height of bld'g h = 25.0 ft '04 �, I : + 1 fil d Project: _ !,� r1t r Job No:. % is PCs \�•� Subject: Sheet � Name: 11141 Structural Solutions Originating Office: ❑ Seattle ❑ Tacoma Date: Vp, 51'� i 4-v � ;a C__ Lat'i Seattle 811 First Avenue, Suite 620 • Seattle, WA 98104 - tel: 206.292.5076 www.pcs- structural.com Tacoma 1250 Pacific Avenue, Suite 701 -Tacoma, WA 98402 • tel: 253.383.2797 SCOPE OF WORK: REPLACE (1) ROOFTOP PACKAGED HVAC UNIT. NEW UNIT TO BE INSTALLED BACK IN SAME LOCATION ON FACTORY CURB ADAPTER. Packaged Unit Willi Curb Adapter Attachment Detell HVAC GENERAL NOTES H TI1E5E PLANS ARE SCHEMATIC AND DO NOT SHOW CKACT ROUTING OR EVERY OFFSET, W fRCf I MAYBE REQUIRED. HVAC CONTRACTOR TO COORDINATE WITH ALL OTHER TRADES 11 ALL WORK SHALLCONFORM TO TILE 111B.B. EN T S OF WASHING I ON ST AT E CODES, REGULAI IONS, ORDINANCES AND TI BE AUTHORITY HAVING IUBISDICTI ON INCLUDING BUT NOT LKV ITED TO ANY OF THE FOLLOWING: IBC 2832, EMC 2012, UPC 2012 AND THE WSEC 2012 31 AIR ECONOMIZERS SHALL BE PROVIDED ON ALL NEW SYSTEMS IF APPLICABLE. CCONOMIZCRS 511AI.L COMPLY Win I SECTIONS C403.4.1.1 THROUGH C403 4.1A OF THE W SEC 2012 4) FEE %IBLE DUCT LENGTHS SHALL NOT E%CEED 10' UNLESS PRIOR APPROVAL HAVE BEEN GIVEN. FLEXIBLE DUCI 10 COMPLY WITH 20121NIC SECTIONS 603.6.1, 603.6.1.1 AND 603.6.4 S)PROVIDE FARTHQHAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH THE CURRENTHIC G) PIPING AND DUCT PENETRATIONS TI IRU F100R5 AND WALLS SHALL BE SLEEVED AND /OR FIRE STOPPED SO AS TO MAINTAIN THE INTEGRITY OF THE SURFACE PER 2012 IMC ED .7 /) MAINTAIN le MINIMUM CLEARANCES TO ALL OUTSIDE AIR AND ECONOMIZER INTAKES FROM ANY EXHAUST VENTS El DUCT WORK TO MEET THE R -VALUE REQUIRMENTS OF THE 2012 WSEC C403.23.1/2 9) ALL DUCT WORK CONSTRUCTED AND SEALED PER 2012 WSEC [403.2.7.1 & C403.2.7.3 Hil EQUIPMENT SCHEDULE PROVIDED PER 2012 WSEC C403.23, C403.2.3.2, C403.2 13 AND C403.2.12.1 11) THERMOSTATIC CONTROLS INDICATED ON PLANS PER WEED C4G3.2.4.1 121 THERMOSTATS 10 PROVIDE 5 DEG DEADBAND MINIMUM ?HR WSEC C403.2.4.2 ER 13) T HMOSI AT TO PROVILIE AUTOMATIC SETBACK & MANUAS OVERRIDF PFR WSEC C403,7A 3 14) ALL NEW HVAC PIPING TO BE INSULATEO PER 2012 WSEC C403.2.8 15) DUCT SMOKE DETECTORS TO BE INSTALLED IN RETURN AIR SYSTENSWITH A DESIGN CAPACITY GREATER THAN 2000 CFM IN THE RETURN AIR DUCT OR PLENUM PER 20121MC 60G.2.1 LOCATION MAP ) MCs _J V) N w Z J Ln UJ CD J � 2w / V Ln w Ldaa, Q � p dw rn Z � I-- Ln v Q Z w J Z) to J w 0 w IWO 71 -s4rg F.R.O. 10 -1 -15 16453 JFS SITE PLAN I NORTH M -1 Single Packaged Convertible Gas /Electric 14 SEER 4YCC4042A1060A 4YCC4042A1090A TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air - conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. December 2014 4YCC4042A -SUB -1 B -EN ItURVIngersol►Rand SAFETY SECTION Important— This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this unit. Please return to service information pack upon completion of work. HAZARDOUS GASES! Exposure to fuel substances or by- products of incomplete fuel combustion is believed by the state of California to cause cancer, birth defects, or other reproductive harm. This warning complies with state of California law, Proposition 65. HAZARDOUS VOLTAGE! Failure to follow this Warning could result in property damage, severe personal injury, or death Disconnect all electric power, including remote disconnects before servicing. Follow proper lockout/tagout procedures to ensure the power cannot be inadvertently energized. SAFETYAND ELECTRICAL HAZARD! Failure to followthis Warning could result in property damage, severe personal injury, or death. These servicing instructions are for use by qualified personnel only. To reduce the risk of electrical shock, do not perform any servicing otherthan that contained in these operating instructions unless you are qualified to do so. GROUNDING REQUIRED! Failure to inspect or use proper service tools may result in equipment damage or personal injury. Reconnect all grounding devices. All parts of this product that are capable of conducting electrical current are grounded. If grounding wires, screws, straps, clips, nuts, or washers used to complete a path to ground are removed for service, they must be returned to their original position and properly fastened. UNIT CONTAINS R -410A REFRIGERANT! Failure to use proper service tools may result in equipment damage or personal injury. R -410A operating pressure exceeds the limit of R- 22. Proper service equipment is required. Service using only R -410A Refrigerant and approved POE compressor oil. SAFETY HAZARD! Operating the unit withoutthe access panels properly installed may result in severe personal injury or death. Do not operate the unit withoutthe evaporator fan access panel or evaporator coil access panel in place. Important. Wear appropriate gloves, arm sleeve protectors and eye protection when servicing or maintaining this equipment. Important. Air filters and media wheels or plates shall meet the test requirements in UL 900. ©2014 Trana 4YCC4042A -SUB -1 B -EN Product Specifications MODEL 4YCC4042A1060A 4YCC4042AI090A RATED Volts /PH /Hz 208- 230/1/60 208 - 230/1/60 Performance Cooling CONSTANTTORQUE ECM BTU 0) 40500 40500 Indoor Airflow (CFM) 1450 1450 Power Input (KW) 3.4 3.4 EER /SEER (BTU /Watt- 3/4/1050 3/4/1050 Hr.) 12.0/14.00 12.0/14.00 Sound Power Rating 6 [dB(A)] (b) 74.6 74.6 PERFORMANCE DIRECT/ 1 DIRECT/ 1 HEATING(c) 1/34/3345 1/34/3075 Input BTUH -1st Stage 230/1/60 230/1/60 (Natural Gas) (d) 60000 90000 AFUE 81 81 Temp. Rise — Min /Max 30/60 35/65 ( °F) 5.3 5.3 Orifice Qty /Drill Sz. 2 / #37 3 / #37 (Natural Gas) 7.3 7.3 POWER CONN. — V/ 208- 230/1/60 208- 230/1/60 Ph /Hz 10° 100 Min. Brch. Cir. 1/2 1/2 Ampacity (e) 28 5 28.5 Fuse Size — Max. 46 X 47_X 62 46 X 47 X 62 (amps) 45 45 Fuse Size — Recmd. 555/452 561/457 (amps) 45 45 COMPRESSOR SCROLL SCROLL VOLTS /PH /HZ 208 - 230/1/60 208- 230/1/60 R.L. Amps — L. R. 16.7/109.0 16.7/109.0 Amps OUTDOOR COIL— SPINE -FIN SPINE -FIN TYPE Rows /F.P.I 2/24 2 / 24 Face Area (sq. ft.) 15.63 15.63 Tube Size (in.) 3/8 3/8 INDOORCOIL- MCHE MCHE TYPE Rows /F.P.I 2/16 2 / 16 Face Area (sq. ft.) 3.9 3.9 Tube Size Width (in.) .81 .81 Refrigeration Control EXPANSION VALVE EXPANSION VALVE Drain Conn. Size (in.) 3/4 FEMALE NPT 3/4 FEMALE NPT OUTDOOR FAN— SWEPT SWEPT TYPE DIA. (IN.) 28.25 28.25 DRIVE /NO.SPEEDS DIRECT /1 DIRECT /1 CFM @ 0.0 in. w.g. M 3400 3400 Motor — HP /R.P.M 1/4/825 1/4/825 4YCC4042A -S1J8-1 B -EN Volts /Ph /Hz 208 - 230/1/60 208- 230/1/60 F.L. Amps /L.R Amps 1.51/3.07 1.51/3.07 INDOOR FAN— TYPE CONSTANT TORQUEECM CONSTANTTORQUE ECM Dia. x Width (in.) 10.62 X 10.62 10.62 X 10.62 Drive /No. Speeds DIRECT/ 3 DIRECT/ 3 CFM @ 0.0 in. w.g. (g) SEE FAN PERF TABLE SEE FAN PERF TABLE Motor— HP /R.P.M. 3/4/1050 3/4/1050 Volts /Ph /Hz 208 - 230/1/60 208 - 230/1/60 F.L. Amps 6 6 COMBUSTION FAN — TYPE CENTRIFUGAL CENTRIFUGAL Drive /No. Speeds DIRECT/ 1 DIRECT/ 1 Motor— HP/R.P.M. 1/34/3345 1/34/3075 Volts /Ph /Hz 230/1/60 230/1/60 FLA .20 .24 FILTER / FURNISHED NO NO Type Recommended THROWAWAY THROWAWAY Recmd. Face Area (sq. ft) (b) 5.3 5.3 REFRIGERANT R -410 R -410 Charge (lbs.) 7.3 7.3 CHARGING SPECIFICATIONS Subcooling 10° 100 GAS PIPE SIZE (in.) 1/2 1/2 DIMENSIONS H X D X W H X D X W Crated (in.) 46 X 47_X 62 46 X 47 X 62 WEIGHT Shipping (lbs.) / Net (lbs.) 555/452 561/457 (a) Rated in accordance with AHRI Standard 210/240. AHRI standard rating conditions are: 80 D.B.67 W.B. entering air to indoor coil. 95 D. B. entering air to outdoor coil. (b) Sound Power values are not adjusted for AHRI 270 -95 tonal corrections. W Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per 1000 ft. elevation. (d) Convertible to LPG. W This value is approximate. For more precise value, see Unit Nameplate. M Standard Air — Dry Coil — Outdoor. (g) Based on U.S. Government Standard Tests. (n) Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m, face velocity. If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C. Outline Drawings 111116 SECTION TYPICAL 181 SIDES OF SIDEFLOW DUCT OPENINGS 16. 18.29 123/303 2] 1272321 11.21 9 /161 SECTION TYPICAL 181 SIDES OF DOWNFLOW DUCT OPENINGS M Figure 1. 4YCC4042 -4060 RECOMMENDED SERVICE CLEARANCE MMIIN. CLEARANCE TO COMBUSTIBLE Note: l he view labeled "Bottom Side" represents the base as viewed looking up from underneath the unit. BOTTOM SIDE 4YCC4042A- SUB -1 B -E N CLEARANCE TO COMBUSTIBLE Note: l he view labeled "Bottom Side" represents the base as viewed looking up from underneath the unit. BOTTOM SIDE 4YCC4042A- SUB -1 B -E N Note: l he view labeled "Bottom Side" represents the base as viewed looking up from underneath the unit. BOTTOM SIDE 4YCC4042A- SUB -1 B -E N Figure 2. 4YCC4042 -4060 Outline Drawings 372.82 114 - 11/16] (OUTSIDE) 58.19 -� [2-9/321 RETURN 322.84 [12- 23/321 SUPPLY 449.02 [17-11 /I6] 79.50 (OUTSIDEI 13-1/8] 449.02 176.07 117-11/161 [6- 15/161 !OUTSIDE) BACK DUCT OPENINGS 60 7/8] 1402.34 [55-7/32] (SURFACE AREA) BACK SIDE Model Height mm /in Approx. Corner Weight - kg / Ibs Shipping Weight kg /Ibs Total Unit Weight kg /Ibs Center of Gravity mm /in A W1 W2 W3 W4 8 C 4YCC4042 (060) 898.53 [35 -3/8] 71.2 [1571 46.6 [103] 34.6 [76] 53.1 [117] 252.2 [555] 202.0 [452] 470.0 [18.5] 731.0 [28.8] 4YCC4042 (090) 898.53 [35 -3/8] 71.8 [158] 47.2 [104] 35.2 [78] S3.6 [118] 254.5 [561] 207.3 [457] 470.0 [18.5] 731.0 [28.8] 4YCC4048 (070) 1000.13 [39 -3/8] 71.4 [1571 44.6 [98] 33.2 [73] 53.9 [119] 250.3 [552] 202.1 [448] 433.0 [17.0] 743.3 [29.3] 4YCC4048 (090) 1000.13 [39 -3/8] 72.0 [1591 45.0 [99] 1 33.8 [75] 54.4 [120] 252.6 [557] 205.4 [453] 433.0 [17.0] 743.3 [29.3] m 1000.13 [39 -3/8] 77.1 [1701 45.8 [101] 34.4 [76] 58.3 [128] 263.1 [580] 215.9 [476] 433.0 [17.0] 743.3 [29.3] 1000.13 [39 -3/8] 78.0 [1721 46.3 [102] 34.9 [77] 59.0 [130] 265.8 [586] 218.6 [482] 414.0 [16.3] 635.0 [25.0] 4YCC4042A -SUB -1 B -EN Outline Drawings 457.20 [181 (INSIDE) 75.41 [2-31/32 Figure 3. 4YCC4042 -4060 [151" IINSIDEI BOTTOM DUCT OPENINGS 24V ENTRY �P --- �1 P-�=I P�4 P:--4 P:--4 P!--4 P-=4� 359.80 294.02 [14 -5/32] a [II -9/161 178.66 1 1 17 -1/321 * � POWER ENTRY 84.96 GAS LINE ENTRY P7.78 DIA. HOLE [3 II/32] I FOR 12.70 11 121 N.P.T. 11 -3/321 GAS CONNECTION 98.66 127.84 13-7/81 RIGHT SIDE [5 -1/321 381.00 [151 (INSIDE) 75 9/161 20 ;IDE) 09 /81 6 4YCC4042A- SUB -1 B -E N Indoor Fan Performance Table 1. Horizontal Airflow 4YCC4042AI060A EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 1 0.9 1.0 HEAT— LOW CFM 1104 1042 977 911 841 764 687 598 - - - WATTS 109 116 124 134 142 152 161 171 - - - HEAT— HIGH CFM - 1171 1112 1050 990 927 851 779 704 - - - WATTS - 154 162 172 182 192 203 214 225 - - COOLING CFM 1358 1393 1348 1296 1253 1204 1157 1096 1057 988 - —LOW WATTS 224 233 242 252 262 272 283 295 305 319 - COOLING—MED CFM 1521 1490 1448 1391 1362 1338 1315 1307 1254 1148 - WATTS 306 316 327 337 348 359 369 382 395 407 - COOLING — HIGH CFM 1659 1637 1604 1594 1529 1491 1467 1425 1385 1345 - —HIGH WATTS 409 421 432 443 455 467 1 477 490 503 513 - 4YCC4042A1090A EXTERNAL STATIC PRESSURE (IN. WG) HEAT— LOW CFM 1419 1380 1341 1295 1249 1204 1160 1115 1069 1015 961 WATTS 240 250 259 269 279 291 302 312 323 333 348 HEAT— HIGH CFM 1559 1524 1483 1443 1401 1363 1319 1276 1233 1195 1147 WATTS 313 324 335 346 356 367 379 392 403 415 428 COOLING — LOW CFM 1358 1393 1348 1296 1253 1204 1157 1096 1057 988 - WATTS 1 24 233 242 252 262 272 283 295 305 319 - COOLING MED CFM 1521 1490 1448 1391 1362 1338 1315 1307 1254 1148 1136 — WATTS 306 316 327 337 348 359 369 382 395 407 - COOLING — HIGH CFM 1659 1637 1604 1594 1529 1491 1467 1425 1385 1345 - WATTS 409 421 432 443 455 467 477 490 503 513 Table 2. Down Airflow 4YCC4042A1060A EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 HEAT CFM 1109 1047 982 916 845 767 690 601 - - - —LOW WATTS 109 117 125 134 143 153 162 172 - - - HEAT— HIGH CFM - 1177 1117 1055 995 931 856 783 707 - - WATTS - 155 163 173 182 193 204 215 226 - - COOLING—LOW CFM 1345 1379 1334 1283 1241 1192 1145 1085 1046 979 - WATTS 228 238 247 257 267 278 289 301 312 325 - COOLING—MED CFM 1506 1475 1433 1377 1348 1325 1302 1293 1241 1136 - WATTS 312 322 333 344 354 366 377 389 403 415 - COOLING CFM 1642 1621 1588 1578 1514 1476 1453 1411 1371 1331 - —HIGH WATTS 417 430 441 452 464 477 487 499 513 523 - 4YCC4042A3090A EXTERNAL STATIC PRESSURE (IN. WG) HEAT— LOW CFM 1426 1387 1348 1301 1255 1210 1166 1120 1074 1020 966 WATTS 241 251 260 270 281 292 303 314 325 335 349 HEAT— HIGH CFM 1567 1531 1491 1450 1408 1370 1326 1282 1239 1201 1152 WATTS 315 325 337 347 358 368 381 394 405 417 430 COOLING—LOW CFM 1345 1379 1334 1283 1241 1192 1145 1085 1046 979 - WATTS 228 238 247 257 267 278 289 301 312 325 - COOLING — MED CFM 1506 1475 1433 1377 1348 1325 1302 1293 1241 1136 - WATTS 312 322 333 344 354 366 377 389 403 415 - COOLING — HIGH CFM 1642 1621 1588 1578 1514 1476 1453 1411 1371 1331 - WATTS 417 430 441 452 464 477 487 499 513 523 4YCC4042A -SUB -1 B -E N Full Perimeter Roof Mounting Curb 1 1/2 \ \ D Figure 4. 4042 — 4060 Models BAYCURBOSIA Full Perimeter Roof Mounting Curb i � A CHANNEL END i i i 38 8 10 7/8 14 The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer \ is not responsible for the unauthorized use of these \ drawings and expressly disclaims any liability for damages resulting from such unauthorized use. B� / 53 1/8 \ \ _C — CHANNEL SIDE WOOiD NAILER ** 42.00 WITH ECONOMIZER WITH 25% FRESH AIR ACCESSORY 4YCC4042A- SUB -1 B -E N SERVICE CLEARANCE DIMENSIONS A B C D WC * /TC* 42.00 36.00 12.00 ** 24.00 DC * /YC* 42.00 36.00 12.00 ** 36.00 ** 42.00 WITH ECONOMIZER WITH 25% FRESH AIR ACCESSORY 4YCC4042A- SUB -1 B -E N Optional Equipment — Filter Rack Figure 5. BAYFLTR101 Filter Rack (4024 -4036) BAYFLTR102 (4042- 4060) (Mounts in Filter /Coil Section) Figure 6. BAYACCD0R1A Hinged Filter Access Door (4024 -4036) BAYACCD0132A (4042 -4060) Replaces Filter /Coil Access Panel Note: The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct; build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 4YCC4042A- SUB -1 B -E N Optional Equipment — Economizer Table 3. BAYECON101,102A Down Discharge Economizer and Rain Hood (Mounts Over Horizontal Return Air Opening) Table 4. BAYCON200, 201A Horizontal Economizer and Rain Hood HVAC Unit Economizer Unit Application Models Economizer Economizer A B C rain hood e - e ee�eeee Gaskets (2) \ y E Rain Hood BAYECON 101A 4024 -036 I Mixed Aire j Outside air Sensor / Economizer Models dampers B C D Return air F BAYECON200AA 4024 -4036 dampers Required 20" 16 -7/8" 15- 11/16" filter kit, order 15" BAYECON201AA Mist separately 22- 21/32" 19" eliminator 14- 11/16" 21 -3/8" BAYEC0NID2A 4042 -060 Relief Return damper E _J Duct Roofcurb I Table 4. BAYCON200, 201A Horizontal Economizer and Rain Hood Note: The drawings on this page are prepared by the manufacturer in order top ro vide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 4YCC4042A -SUB -1 B -EN Economizer A B C Gaskets (2) \ y E Rain Hood I � i % I Mixed Aire j / Sensor / Economizer Models A B C D E F BAYECON200AA 4024 -4036 22" 20" 16 -7/8" 15- 11/16" 11- 11/16" 15" BAYECON201AA 4042 -4060 26" 22- 21/32" 19" 17- 11/16" 14- 11/16" 21 -3/8" Note: The drawings on this page are prepared by the manufacturer in order top ro vide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 4YCC4042A -SUB -1 B -EN Optional Equipment — Outside Air Damper Table 5. BAYOSAH001 and 002A I� AEI Manual Fresh Air Model Unit Application Models A B C D \ FU OP LLY EN BAYOSAH001A 4024 -4036 22- 7/16" 20- 11/16" 12 -3/8" 9- 3/16" � 2/3 \f a �lor BAYDMPR102A 4042-4060 25- 3/16" 20- 11/16" 12 -3/8" 9- 3/16" FULLY B CLOSED LI- BAYOSAH002A 4042-4060 25- 3/16" 20- 11/16" 12 -3/8" 9- 3/16" Table 6. BAYDMPR101 and 102A,25% Motorized Outside Air Damper (Mounts Over Horizontal Return Air Opening) A �I Manual Fresh Air Model Unit Application Models A B C D r. BAYDMPR101A 4024-4036 22- 7/16" 20- 11/16" 12 -3/8" 9- 3/16" C a E ♦ BAYDMPR102A 4042-4060 25- 3/16" 20- 11/16" 12 -3/8" 9- 3/16" Note: The drawings on this page are prepared by the manufacturer in order to provide detail regarding jab layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 4YCC4042A -SUB -1 B -EN Mechanical Specifications General The units shall be horizontal airflow as shipped and convertible to downflow. All units shall be factory assembled, piped, internally wired and fully charged with refrigerant. Units shall be certified to UL Standard 1995. Units shall be designed to operate at ambient temperatures as high as 115 °F. Cooling performance shall be rated in accordance with AHRI standards. The YC heating /cooling unit design is certified to ANSI 221.47/CSA 2.3, specifically for outdoor applications using natural gas or propane. All units shall be designed for outdoor rooftop or ground level installation. Unit Casing All components shall be mounted in a weather - resistant steel cabinet with an enamel finish. Access panels shall be provided for unit controls and indoor coil and fans. Indoor air section compartment shall be completely insulated with fireproof, permanent, odorless fiber material. Knockouts shall be provided for utility and control connections. Drain connections shall be provided to accommodate indoor water runoff. Compressor The compressor shall be hermetically sealed, high efficiency scroll compressors. Internal overcurrent and overtemperature protection, internal pressure relief shall be standard. Other features include centrifugal oil pump, low vibration and noise. Refrigeration System All units shall have refrigerant control. Service pressure tap ports and a refrigerant line filter shall be standard. Evaporator Coil (2 -4 Ton Models) All aluminum micro channel, extruded tubes, mechanically bonded to aluminum fins, and factory pressure and leak tested at 480 —650 psig. All units have TXV to control refrigerant flow. Condenser Coil The Spine Fin TM condenser coil shall be continuously wrapped, corrosion resistant all aluminum with minimum brazed joints. This coil is 3/8" OD seamless aluminum tubing glued to a continuous aluminum fin. Coils are lab tested to withstand 2.000 pounds of pressure per square inch. The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Indoor Air Fan Constant Torgue, forward - curved, centrifugal wheel in a Composite Vortica ® Blower housing. Motor shall have thermal overload protection and permanently lubricated motor bearings. Motor /blower assembly isolated from unit with rubber mounts. Outdoor Fan One direct - drive, statically and dynamically balanced propeller fan shall be used in a draw - through vertical discharge configuration. Permanently lubricated weather proof motor shall have built -in thermal overload protection. System Controls System controls include condenser fan, evaporator fan and compressor contactors. Accessories Roof Curb The roof curb shall be designed to mate with the unit and provide support and complete weathertight installation when properly installed. Adhesive back polyurethane sealing strips shall be provided to ensure an airtight seal between supply and return openings of the curb and unit. The roof curb design allows field fabricated ductwork to be connected directly to the curb. Curb ships knocked down for field assembly, and includes factory installed wood nailer strips. Heating System Gas -Fired Heating Section Models shall provide completely assembled, wired and piped gas fired heating systems within unit. Design certified by UL, specifically for outdoor application. Threaded gas connection on the unit. Electric Ignition System Main burner is lit each time thermostat calls for heat. Flame sensor proves flame and keeps the main burner on. Should a loss of flame occur, the main valve closes and the spark recurs within 0.8 seconds. When thermostat is satisfied, main burner is extinquished. Forced Combustion Blower Insures flame stability under varying wind conditions. Gives higher combustion efficiency and location flexibility. Heat Exchanger Stainless steel tubes. Free floating design. Burners Stainless steel. Multi -port inshot. 12 4YCC4042A- SUB -1 B -EN Single Source Power Entry This accessory when used with electric heat accessory shall allow single source power connection to unit and heater combination. Single source power entry kits shall have specific matching heater(s). Kit shall include high voltage terminal blocks, fuse blocks and fuses, cut - to- length interconnecting wiring, and junction box (if required) to provide power sources with fuse protection as required for both the unit and accessory heater. Kit components shall install within the heater cabinet in the heater access section. Single source branch power circuit shall be protected and wired in accordance with local codes. Fully Modulating Economizer This accessory shall be field installed and be composed of the following items: 0 -100 % fresh air damper, damper drive motor, fixed dry bulb enthalpy control, and low voltage pigtails for electrical connections. Solid state enthalpy or differential enthalpy control is optional. Economizer operations shall be controlled by the preset position of the enthalpy control. A barometric relief damper shall be standard with the economizer and provide a pressure operated damper Mechanical Specifications that shall be gravity closing and prohibit entrance of outside air on equipment "off" cycle. Economizer requires BAYRLAY004A relay kit to interface the economizerto the heat pump. Manual Outside Air Dampers Rain hood and screen shall be field installed. Suitable for up to 25% outside air. Start Kit Extra compressor starting capacity for single phase equipment. Control Options Standard Indoor Thermostats Two stage heating /cooling or one stage heating /cooling thermostats shall be available in either manual or automatic changeover. Programmable Electronic Night Setting Thermostat Programmable electronic thermostat shall provide heating setback and cooling setup with 7 —day programming capability. 1H /1C or 2H /2C models available. c US �,s�o Intertek The manufacturer optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments, the manufacturer offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information, visit www.[RCO.com. The manufacturer has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. ©2014 Trans /. 4YCC4042A- SUB -1B-EN 01 Dec 2014 '-� Ingersoll Rand Supersedes 4YCC4042A- SUB -IA -EN (November 2014) (H