Loading...
20160152 Interior Lighting Summary 021920162012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 Project Address 1304 Yelm Ave. Date 2/19/2016 Lighting Alterations, Renovations & Building Additions For Building Department Use 0 Less than 60% 0 60% or more 0 Stand alone 0 Addition Food Prep Service Area Notes: 8 a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be 288 combined with the overall existing bldg lighting to demonstrate compliance. Refer to C101.4.3. 2' x 2' Troffer 36 Watt LED b. For retrofits and building additions, provide Space Types and gross interior areas in the 36 Maximum Allowed Lighting table. If a builidng addition will comply as combined with the overall Lobby existing builidng, include all applicable existing Space Types and gross interior areas. 8 c. Document new fixtures and all existing to remain fixtures in the Proposed Lighting table. 336 d. If less than 60% of existing fixtures will be replaced, provide total existing lighting wattage Pendant Light Small 3 Watt LED (prior to retrofit) in the space provided in the Maximum Allowed Lighting table. 3 Maximum Allowed Lighting Wattage Location (plan #, Pendant Light Large 4 Watt LED Allowed Gross Interior Watts Allowed room #) Space Type* Watts per ft2 Area in ft2 (watts /ft2 x area) Lobby Dining area: Family dining area 0.89 702 625 Bathroom Restroom 0.98 53 52 Food Prep Service Food preparation 0.99 475 4 7 0 Area Retail Display Lighting from LTG -INT- DISPLAY Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watt 843 Atrium ** Enter Height: Existing Lighting Enter Exist. Watts: Retail Display Allowance from LTG -INT- DISPLAY * Select Table C405.5.2(2) category from drop down menu. ** For atriums, indicate height. Allowed wattage for first 40 feet is 0.03 W /ft. ht., above 40 feet is 0.02 W /ft. ht. Proposed Lighting Wattage Area Allowed Watts Total 1230 1147 Location (plan #, room #) Fixture Description * ** Number of Fixtures Watts/ Fixture Watts Proposed Food Prep Service Area 2' x 2' Troffer 36 Watt LED 8 36 288 Bathroom 2' x 2' Troffer 36 Watt LED 1 36 36 Lobby Mini High Bay 42 Watt Fluorescent 8 42 336 Lobby Pendant Light Small 3 Watt LED 9 3 27 Lobby Pendant Light Large 4 Watt LED 4 4 16 Food Prep Service Area Downlight 17 Watt LED 3 17 51 Lobby Downlight 17 Watt LED 1 17 17 Lobby Track Light 4'w/2 9 Watt LED Heads 4 18 72 Retail Display Lighting from LTG -INT- DISPLAY Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watt 843 * ** Include existing to remain lighting fixtures and exempt lighting equipment per notes below. Notes: 1. Include ALL proposed lighting fixtures. 2. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 3. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices of the transformer. For low voltage track lighting list the transformer rated wattage. 4. For lighting equipment eligible for exemption per C405.5.1, note exception number and leave Watts /Fixture blank. 5. Document existing to remain fixtures in Proposed Lighting table in the same manner as new fixtures. Identify as existing in fixture description 6. If #NA appears in Retail Display cells, information on L TG-INT-DISPLA Y is incomplete. (Interior Lighting Power Allowance COMPLIES