TRANSMITTAL
RE: Easthaven Villa Memory Care Neighborhood
Enclosed are the following to go with the previously submitted drawings:
One thumb drive containing all 3 -18 -2016 drawings and specifications-
1 . Updated Architectural Drawings.
2. Updated Mechanical Drawings including Plumbing.
3. Updated Electrical Drawings.
4. Existing Structural Drawings — no changes.
5. Current Architectural Specifications.
6. Updated Mechanical Specification.
7. Current Electrical Specifications — no changes.
2012 WEC Compliance Forms:
Exterior Lighting Summary
Lighting, Motor and Transformer Permit Documents Checklist, 2 pages
Interior Lighting Summary — Building Area Method
���gIIdg]
?0 ?5
BY-------------- - - - - --
;Exterior • • Summary LTG-EXT
2012 Washington State Energy Code Compliance Forms for Commercial Buildings includinq R2 8 R3 over 3 stories and all R1 Revised Jan 2014
Project Info
Project Address: 311 CULLENS RD NW YELM, WA. 98597
Date 3/24/2016
Watts/
Fixture
For Building Department Use
Main Entry Door
Applicant Name: EASTHAVEN VILLA MEMORY CARE NEIGHBORt
Applicant Addr: 311 CULLENS RD NW YELM, WA. 98597
Applicant Phone: 503- 357 -3793
Project Description
❑ New Building ❑ Addition ❑ Alteration ❑ Plans Included
Lighting Zone
As specified by jurisdiction. Zone selection
required to enable LTG -EXT form
❑ Zone 1 ❑ Zone 2 Zone 3 1_1 Zone 4
Compliance Option
Q Lighting Power Density Calculations ❑ Total Building Performance
Building Grounds
Applies to luminaires > 100 Watts
❑ Efficacy > 60 lumens/W ❑ Controlled by motion sensor
❑ Exemption (list)
Exterior Lighting Alterations
❑ No changes are being made to the existing exterior lighting
❑ New wiring installed to serve added fixtures and /or fixtures relocated to new circuit
Provide applicable exterior lighting controls per C405.2.4 and commissioning per
Tradable Maximum Allowed Lighting Wattage Base Site Allowance:
750
Tradable Surfaces
Surface Description
Allowed a s
per ft2 or per If
Area (ft'), perimeter
(If) or # of items
_7kTowed Watts
x ft2 (or x If)
Uncovered Parking and
drives
drive
0.10 W /ft2
2468
Unlit
Main Entry Door
entry door
30W /LF door
width
3
90
Total Allowed Tradable Watts:
90
1 radaDle Proposed Llgnnng Wattage (use mfgr listed maximum input wattage for luminaire.)
Tradable Surface
Fixture Description
Number of
Fixtures
Watts/
Fixture
Watts
Proposed
Main Entry Door
WP1 led wall pack 2485 lumen
1
26
26
212
795
1
72
72
r oral proposes uaoaDle watts may not exceed the sum of total allowed tradable Total Proposed Tradable Watts: 2 6
watts plus the base site allowance. Any base site allowance not needed to make
tradable watts comply can be applied to individual non - tradable categories.
Non -1 radable Maximum Allowed Lighting Wattage Base Site Allowance Remaining:
750
Non - Tradable Surfaces
Surface Description
Allowed Watts
per ft2 or per If
Area (ft), perimeter
(If) or # of items
Allowed Watts
x ft2 (or x If)
Bldg. Facade (by Perim)
garage perimeter
3.75 W /lf
212
795
1
72
72
Non- lradable 1 roposed Lighting Wattage
Non - Tradable Surface
Fixture Description
Number of
Fixtures
Watts/
Fixture
Watts
Proposed
Bldg. Facade (by Perim)
WPl led wall pack 2485 lumen
3
26
78
Bldg. Facade (by parim)
WP2 led wall pack 6538 lumen
1
72
72
—rr -uaua— prupusuu waits may not exceed allowed watts ror any individual Total excess Non - Tradable watts: 0
surface un less the total excess watts for all non - tradable surfaces are less than the
remaining site allowance. Site Allowance Balance: 750
Exterior Lighting COMPLIES WITH SITE ALLOWANCE
IMCMITT]
BY: -------------- - - - - --
Lighting, Motor, and Transformer Permit Documents Checklist LTG-CHK
2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014
Project Address 311 CULLENS RD NW YELM, WA 98597 Date 3/24/2016
The following information is necessary to check a permit application for compliance with the lighting, motor, and transformerrequirements in the
Washington State Energy Code, Commercial Provisions.
Applicability I
Location in
Building Department
(yes,no,na) Code Section
Component
Compliance information required in permit documents
Documents
Notes
LIGHTING CONTROLS (Section C405.2)
Indicate on plans the manual control type & locations served,
E33
Yes
0405.2.1.1
0405.2.1.2
Manual interior
lighting controls
- - -- -
Indicate of plans the 50% lighting load reduction method
EXCEPTION 2
provided or identify exception taken
Indicate lighting system automatic shut -off capability- identify
E33
lighting zone areas served on plans;
Tres
0405.2.2.1
Automatic time
switch controls and
Indicate locations of override switches on plans and the areas
E33
override switching
served, include area sq. ft.;
Indicate locations where automatic shutoff is provided by other
E33
methods (occupancy sensor, daylight controls, etc)
Yes
C405222
Occupancy sensors
Indicate on plans the locations served by occupancy sensors
E33
Daylight zones -
Indicate vertical fenestration primary and secondary daylight
E33
Yes
C405.2.2.3
Vertical fenestration
zone areas on plans, include sq fL;
and skylights
Indicate skylight daylight zone areas on plans, include sq. ft.
NA
Yes
Daylight zone
Indicate on plans the locations served by daylight zone controls;
E33
C405.2.2.3.2
controls
- - -_
Indicate in plans the lighting load reduction (dimming) method -
stepped or continuous dimming
E33
Specific application
Indicate on plans the locations served by specific application
NA
C405.2.3
lighting controls -
lighting controls
General
Indicate lighting control method for display and accent lighting,
and display case lighting;
KA
0405.2.3 -
Display and accent
Indicate these fixtures are controlled independently from both
Items 1&2
lighting
general area lighting and other lighting applications within the
same space
0405.2.3 -
Hotel /motel guest
Provide a lighting control device at each guest room entry for all
NA
Item 3
rooms
permanently installed fixtures in guest room;
._._
Indicated whether lighting control is manual or automatic
C405.2.3 -
Supplemental task
Provide automatic shut -off vacancy controls for supplemental
Item 4
lighting
task lighting, including under -shelf or under-cabinet lighting
Identify eligible non - visual applications and method of lighting
control;
0405.2.3 -
Lighting for non-
-- — --
-
NA
Item 5
visual applications
Indicate these fixtures are controlled independently from both
general area lighting and other lighting applications within the
same space
Indicate lighting control method for lighting equipment for sale
0405.2.3 -
Lighting equipment
or demonstration; --
KA
Item 6
for sale or
Indicate these fixtures are controlled independently from both
demonstration
general area lighting and other lighting applications within the
same space
If egress lighting power density is greater than 0.05W /ft2,
0405.2.3 -
Means of egress
indicate method of automatic shut -off during unoccupied
NA
Item?
lighting
i;
periods',
Identify on plans the egress fixtures that function as both normal
and emergency means of egress illumination
0405.10
Cooler and freezer
Provide vacancy device or timer to turn off fixtures within 15
NA
0405.11
lighting
minutes of unoccupancy for cooler and freezer lighting fixtures
with lamp efficacy less than 40 lumens per watt
Yes
C405.2.4
Exterior lighting
Indicate on exterior lighting plans the automatic lighting control
controls
method and locations served
E33
Exterior building
Provide motion sensor controls for building grounds fixtures
NA
C405.6.1
grounds lighting
rated at greater than 100 watts with lamp efficacy less than 60
controls
lumens, or identify exception taken
Identify applicable commissioning documentation requirements
per Section C408 or eligibility for exception;
NA
C408.3
Lighting system
Provide written procedures for functional testing of all automatic
functional testing
controls and describe the expected system response,
Identify in construction documents the party responsible for
functional testing of automatic lighting controls
INTERIOR LIGHTING POWER & EFFICACY Sections C405.5, C405.10, C405.11
Lighting, Motor, and Transformer Permit Documents Checklist LTG-CHK
2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014
Project Address 311 CULLENS RD NW YELM, WA. 98597 Date 3/24/2016
The following information is necessary to check a permit application for compliance with the lighting, motor, and transformerrequirements in the
Washington State Energy Code, Commercial Provisions.
Applicability
Location in
Building Department
(yes,no,na)
Code Section
Component
Compliance information required in permit documents
Documents
Notes
Provide fixture schedule with fixture types, lamps, ballasts, and
rated watts per fixture;
E61
C405.5.1
Identify spaces eligible for lighting power exemption on plans
0405.5.1.1
Total connected
and in compliance forms;
NA
Yes
0405.5.1.2
interior Ii htin power
9 9
Identify lighting g' p
fY 9 9 equipment eligible for exemption in fixture
C405.5.1.3
C405.5.1.4
schedule and in compliance forms;
NA
Indicate that exempt lighting equipment is in addition to general
NA
area lighting and is controlled independently
NA
C405.4
Exit signs
Provide exit sign types and rated watts per fixture in fixture
schedule (maximum 5 watts per fixture)
0405.10
Cooler and freezer
For lighting in walk -in coolers and freezers, and refrigerated
NA
0405.11
lighting
warehouse coolers and freezers, provide rated lamp efficacy (in
lumens per watt) in fixture schedule
Lighting Power Calculation - Indicate compliance path taken
Complete required compliance forms — proposed wattage per
NA
C405.5.2
Building Area Method
building area does not exceed maximum allowed wattage per
building area. Identify locations of building areas on plans
Complete required compliance forms — total proposed wattage
Yes
0405.5.2
Space -By -Space
does not exceed maximum allowed wattage. Identify locations
E33
Method
of space types on plans, including retail display areas as
applicable
EXTERIOR LIGHTING POWER & EFFICACY Section C405.6
Provide fixture schedule with fixture types, lamps, ballasts, and
rated watts per fixture;
- -- - --
E61
Yes
0405.6.2
Total connected
exterior lighting
Identify exterior applications eligible for lighting power
KA
exemption on plans and in compliance fortes;
power
Indicate that exempt exterior lighting is controlled independently
from non-exempt exterior lighting
NA
Table
Exterior lighting zone
Indicate building exterior lighting zone as defined by the AHJ
FORMS
C405-6-2(l)
Exterior building
For building grounds fixtures rated at greater than 100 watts,
NA
0405.6.1
provide rated lamp efficacy (in lumens per watt) in fixture
grounds lighting
schedule
Exterior lighting
Complete required compliance forth — proposed wattage for
Yes
C405.6.2
exterior lighting plus base site allowed does not exceed
FORMS
power calculations
maximum allowed
MOTORS & TRANSFORMERS (Sections C405.8, C405.9)
NA
C405.8
Electric Motors
For motors not part of an HVAC system, provide electric motor
schedule on electrical plans with hp, rpm, and rated efficiency
NA
0405.9
Transformers
Provide distribution transformer schedule on electrical plans
with transformer size and efficiency
It "no" is selected for any
Interior Lighting Building Area Method
2012 Washington State Energy Code Compliance Forms for Commercial Buildinqs includinq R2 8 R3 over 3 stories and all RI Revised Jan 2014
Project Address 311 CULLENS RD NW YELM, WA. 98597
Date 3/24/2016
Lighting Alterations, Renovations & Building Additions
0 Less than 60% � � 60% or more Stand alone _% Addition
Notes:
a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be
combined with the overall existing bldg lighting to demonstrate compliance. Refer to C101.4.3.
b. For retrofits and building additions, provide Building Area types and gross interior areas in the
Maximum Allowed Lighting table. Ilia builidng addition will comply as combined with the overall
existing builidng, include all applicable existing Building Area types and gross interior areas.
c. Document new fixtures and all existing to remain fixtures in the Proposed Lighting table-
d. If less than 60% of existing fixtures will be replaced, use LTG -INT -SPACE form.
For Building Department Use
Space -By -Space method selected. Use LTG -INT -SPACE form.
Building Area`
Location (plan #,
I room #, or ALL)
Area Description
Allowed
Watts per ft2
Gross Interior
Area in It'
W-affs—Allowed
(watts /ft2 x area)
Warehouse
GARAGE
GARAGE WITH BATHROOM
0.50
3480
1740
1160
Select Table C405.5.2(1) Building Area from drop down menu. Total
3480
Space -By -Space metf t;,d selected. Use LTG -INT -SPACE form,
Building Area`
Location (plan #,
room #)
Fixture Description"
Number of
Fixtures
Watts/
Fixture
Watts
Proposed
Warehouse
Bathroom
A7 vanity fixture led 2000 lumen
1
18
18
Warehouse
Garage
SL2 strip light led 4000 lumen
29
40
1160
Select Table C405.5.2(1) Building Area from drop down menu.
" Include existing to remain lighting and exempt lighting equipment per notes below.
Compliance by Building Area
Building Area
Warnings
Total Allowed
Watts
Total Proposed
Watts
Interior Lighting Power
Allowance
Warehouse
1740
1178
"IMPLIFS
Totall 1740 1 1178
Notes:
1. Proposed Wattage for each Building Area type shall not exceed the Allowed Wattage for that Building Area type. Trading wattage between
Building Area types is not allowed under the Building Area Method compliance path.
2. Proposed fixtures must be listed in the building area in which they occur. Include ALL proposed lighting fixtures.
3. For proposed Fixture Description, indicate fixture type, lamp type (e. g. T -8), number of lamps in the fixture, and ballast type (if included). For
track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information.
4. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria
as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50,
or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage.
5. For lighting equipment eligible for exemption per C405.5.1, note exception number and leave Watts/Fixture blank.
6. Document existing to remain fixtures in Proposed Lighting table in the same manner as new fixtures. Identify as existing in fixture description.