20140275 LTG-EXT 03282016:Exterior • • Summary LTG-EXT
2012 Washington State Energy Code Compliance Forms for Commercial Buildings induding R2 8 R3 over 3 stories and all R1 Revised Jan 2014
Project Info
Project Address: 311 CULLENS RD NW YELM, WA. 98597
Date 3/24/2016
Watts/
Fixture
For Building Department Use
Main Entry Door
Applicant Name: EASTHAVEN VILLA MEMORY CARE NEIGHBORF
Applicant Addr: 311 CULLENS RD NW YELM, WA. 98597
Applicant Phone: 503- 357 -3793
Project Description
[ New Building E Addition Alteration ❑ Plans Included
Lighting Zone
As specified by jurisdiction. Zone selection
required to enable LTG- EXTform
O Zone 1 O Zone 2 Zone 3 n Zone 4
Compliance Option
(* Lighting Power Density Calculations 0 Total Building Performance
Building Grounds
Applies to luminaires > 100 Watts
❑ Efficacy > 60 IumensNV Controlled by motion sensor
❑ Exemption (list)
Exterior Lighting Alterations
❑ No changes are being made to the existing exterior lighting
New wiring installed to serve added fixtures and /or fixtures relocated to new circuit
Provide applicable exterior lighting controls per C405.2.4 and commissioning per
Tradable Maximum Allowed Lighting Wattage Base Site Allowance:
750
Tradable Surfaces
Surface Description
AllowedWafts
per ft2 or per If
Area (ft"), perimeter
(If) or # of items
AllowedWafts
x fe (or x If)
Uncovered Parking and
drives
drive
0.10 W /ft2
2468
Unlit
Main Entry Door
entry door
30W /LF door
width
3
90
Total Allowed Tradable Watts:
gp
1 raQaDle Yroposea Lignnng vvattage (Use mfgr listed maximum input wattage for luminaire.)
Tradable Surface
Fixture Description
Number of
Fixtures
Watts/
Fixture
Watts
Proposed
Main Entry Door
WP1 led wall pack 2485 lumen
1
26
26
212
795
1
72
72
Total proposed tradable watts may not exceed the sum of total allowed tradable Total Proposed Tradable Watts: 26
watts plus the base site allowance. Any base site allowance not needed to make
tradable watts comply can be applied to individual non - tradable categories.
Non - Tradable Maximum Allowed Lighting Wattage Base Site Allowance Remaining:
750
Non - Tradable Surfaces
Surface Description
Allowed Watts
per ft' or per If
Area (fl?), perimeter
(if) or # of items
Allowed Watts
x ft' (or x If)
Bldg. Fagade (by perim)
garage perimeter
3.75 W /lf
212
795
1
72
72
Non - Tradable Proposed Lighting Wattage
Non - Tradable Surface
Fixture Description
Number of
Fixtures
Watts/
Fixture
Watts
Proposed
Bldg. Fagade (by Perim)
WP1 led wall pack 2485 lumen
3
26
78
Bldg. Fagade (by Perim)
WP2 led wall pack 6538 lumen
1
72
72
tvon- rraoawe proposed watts may not exceed allowed watts for any individual Total excess Non - Tradable watts: 0
surface unless the total excess watts for all non - tradable surfaces are less than the
remaining site allowance. Site Allowance Balance: 750
Exterior Lighting COMPLIES WITH SITE ALLOWANCE
MiKI