20140275 LTG-INT-BLD 032420161*1 11 • ' • •
— 1.,nim „ R9 R R3 raver 3 strin— and all R1 Revised Jan 2014
Project Address 311 CULLENS RD NW YELM, WA. 98597
Date 3/24/2016
Lighting Alterations, Renovations & Building Additions
For Building Department Use
0 Less than 60% O 60% or more Stand alone 'J Addition
Watts
Proposed
Notes:
a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be
Bathroom
combined with the overall existing bldg lighting to demonstrate compliance. Refer to C101.4.3.
1
b. For retrofits and building additions, provide Building Area types and gross interior areas in the
18
Maximum Allowed Lighting table. If a builidng addition will comply as combined with the overall
Garage
existing builidng, include all applicable existing Building Area types and gross interior areas.
29
c. Document new fixtures and all existing to remain fixtures in the Proposed Lighting table.
1160
d. If less than 60% of existing fixtures will be replaced, use LTG -INT -SPACE form.
Space -By -Space method selected. Use LTG -INT -SPACE form.
Location (plan #,
owe
Gross nterior
a s owe
Building Area”
I room #, or ALL)
Area Description
Watts per ft2
Area in ft2
(watts /ft2 x area)
Warehouse
GARAGE
GARAGE WITH BATHROOM
0.50
3480
1740
* Salad Tahla cans s 21`1) Ruildinr Area from drop down menu. Total
3480
Cr.ara_Rh ..Cnary mPthnd selected. Use LTG -INT -SPACE form,
Building Area*
Location (plan #,
room #)
Fixture Description`*
Number of
Fixtures
Watts/
Fixture
Watts
Proposed
Warehouse
Bathroom
A7 vanity fixture led 2000 lumen
1
18
18
Warehouse
Garage
SL2 strip light led 4000 lumen
29
40
1160
Select Table C405.5.2(1) Building Area from drop down menu.
" Include existing to remain lighting and exempt lighting equipment per notes below.
C'mmnliance by Building Area
Building Area
Warnings
Total Allowed
Watts
Total Proposed
Watts
Interior Lighting Power
Allowance
Warehouse
1740
1178
COMPLIES
Totall 1740 1178
Notes:
1. Proposed Wattage for each Building Area type shall not exceed the Allowed Wattage for that Building Area type. Trading wattage between
Building Area types is not allowed under the Building Area Method compliance path.
2. Proposed fixtures must be listed in the building area in which they occur. Include ALL proposed lighting fixtures.
3. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For
track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information.
4. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria
as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50,
or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage.
5. For lighting equipment eligible for exemption per C405.5.1, note exception number and leave Watts/Fixture blank.
6. Document existing to remain fixtures in Proposed Lighting table in the same manner as new fixtures. Identify as existing in fixture description.